Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.9 CrAccepted-AOC | ₹2.9 Cr | L1 | Accepted-AOC BEING L1 |
| 2 | L2₹3.0 Cr+₹8.6 L (2.95%)Rejected-AOC | ₹3.0 Cr+₹8.6 L (2.95%) | L2 | Rejected-AOC NOT BEING L1 |
| 3 | L3₹3.0 Cr+₹8.7 L (2.99%)Rejected-AOC | ₹3.0 Cr+₹8.7 L (2.99%) | L3 | Rejected-AOC NOT BEING L1 |
| 4 | L4₹3.3 Cr+₹39.8 L (13.7%)Rejected-AOC | ₹3.3 Cr+₹39.8 L (13.7%) | L4 | Rejected-AOC NOT BEING L1 |
| 5 | L5₹3.8 Cr+₹94.2 L (32.5%)Rejected-AOC FLAT NO 5 10 3 73 6 AMAR APARTMENTS TEACHERS COLONY EAST MARREDPALLY SECUNDERABAD 500026 | SECUNDERABAD | HYDERABAD | TELANGANA | 500026 | ₹3.8 Cr+₹94.2 L (32.5%) | L5 | Rejected-AOC NOT BEING L1 |
| Sl No | Description | Qty | Unit | Indu Electricals L2 | Sri Associates L4 | INDGUARD ENGINEERS L3 | B.N.S Constructions L5 | SRIDEVI CONSTRUCTIONS L1 |
|---|---|---|---|---|---|---|---|---|
| .50BOQ Dated Aug 2025 | ||||||||
| .75GENERAL SUMMARY NOTE: Schedule ‘A’ Part I to XIV are prepriced by MES under Ser No. 1 to 14. Bidders shall insert their lumpsum amount in the Green coloured field under Col-6 only. | ||||||||
| 1.00 | Lumpsum price worked out by the contractor for “BUILDINGS OR WORKS” as listed in Schedule ‘A’ Part–I | 1 | Lumpsum | 2,34,00,000 ₹2,34,00,000 | 2,55,00,000 ₹2,55,00,000 | 2,25,46,519 ₹2,25,46,519 | 3,06,07,000 ₹3,06,07,000 | 2,16,97,000 ₹2,16,97,000 Lowest |
| 2.00 | Lumpsum price worked out by the contractor for “INTERNAL WATER SUPPLY” as listed in Schedule ‘A’ Part–II | 1 | Lumpsum | 1,79,000 ₹1,79,000 | 3,01,000 ₹3,01,000 | 1,65,000 ₹1,65,000 | 3,87,450 ₹3,87,450 | 1,61,005 ₹1,61,005 Lowest |
| 3.00 | Lumpsum price worked out by the contractor for “INTERNAL ELECTRIC SUPPLY" as listed in Schedule ‘A’ Part–III | 1 | Lumpsum | 13,50,000 ₹13,50,000 | 12,67,665 ₹12,67,665 Lowest | 13,50,000 ₹13,50,000 | 14,50,422 ₹14,50,422 | 13,42,233 ₹13,42,233 |
| 4.00 | Lumpsum price worked out by the contractor for “SITE CLEARANCE AND LAND DEVELOPEMENT" as listed in Schedule ‘A’ Part -IV . | 1 | Lumpsum | 14,50,000 ₹14,50,000 | 18,75,822 ₹18,75,822 | 15,00,000 ₹15,00,000 | 11,82,843 ₹11,82,843 Lowest | 16,15,540 ₹16,15,540 |
| 5.00 | Lumpsum price worked out by the contractor for "PATH/HARDSTANDING" as listed in Schedule ‘A’ Part -V . | 1 | Lumpsum | 6,50,000 ₹6,50,000 Lowest | 8,41,036 ₹8,41,036 | 7,65,000 ₹7,65,000 | 8,26,200 ₹8,26,200 | 7,56,932 ₹7,56,932 |
| 6.00 | Lumpsum price worked out by the contractor for “AREA DRAINAGE” as listed in Schedule ‘A’ Part – VI. | 1 | Lumpsum | 6,50,000 ₹6,50,000 Lowest | 7,99,019 ₹7,99,019 | 7,00,000 ₹7,00,000 | 6,72,750 ₹6,72,750 | 7,19,147 ₹7,19,147 |
| 7.00 | Lumpsum price worked out by the contractor for “SEWAGE DISPOSAL” as listed in Schedule ‘A’ Part – VII. | 1 | Lumpsum | 4,50,000 ₹4,50,000 Lowest | 5,18,040 ₹5,18,040 | 5,00,000 ₹5,00,000 | 5,21,460 ₹5,21,460 | 4,88,205 ₹4,88,205 |
| 8.00 | Lumpsum price worked out by the contractor for “GARBAGE BIN" as listed in Schedule ‘A’ Part- VIII. | 1 | Lumpsum | 1,50,000 ₹1,50,000 | 1,50,000 ₹1,50,000 | 1,45,000 ₹1,45,000 | 1,42,470 ₹1,42,470 Lowest | 1,47,305 ₹1,47,305 |
Tender Value
₹2.8 Cr
EMD Value
₹3.6 L
Closing Date
3 Sept 2025, 6:00 pmClosed
Chief Engineer AF Bangalore
Chief Engineer AF Bangalore No. 2 DC Area MES Road Yeshwantpur Post Bangalore 560022
DEMOLITION OF BUILDING NO T-39 AND RECONSTRUCTION OF LIVING IN OFFICERS ACCN AT AFS BEGUMPET
2025_MES_719938_1
801664/AF/E8
Open Tender
Civil Works
Lump-sum
420 days
GE(AF)HAKIMPET
AS PER NIT
8 documents required · 8 mandatory
₹2,000
GE(AF)HAKIMPET
₹3.6 L
Yes
22 Sept 2025
11 Jul 2025
10 Sept 2025
11 Jul 2025
3 Sept 2025
20 Aug 2025
12 Jul 2025 - 21 Jul 2025
Amount
BOQ Dated Aug 2025
GENERAL SUMMARY NOTE: Schedule ‘A’ Part I to XIV are prepriced by MES under Ser No. 1 to 14. Bidders shall insert their lumpsum amount in the Green coloured field under Col-6 only.
Lumpsum price worked out by the contractor for “BUILDINGS OR WORKS” as listed in Schedule ‘A’ Part–I
Lumpsum price worked out by the contractor for “INTERNAL WATER SUPPLY” as listed in Schedule ‘A’ Part–II
Lumpsum price worked out by the contractor for “INTERNAL ELECTRIC SUPPLY" as listed in Schedule ‘A’ Part–III
Lumpsum price worked out by the contractor for “SITE CLEARANCE AND LAND DEVELOPEMENT" as listed in Schedule ‘A’ Part -IV .
Lumpsum price worked out by the contractor for "PATH/HARDSTANDING" as listed in Schedule ‘A’ Part -V .
Lumpsum price worked out by the contractor for “AREA DRAINAGE” as listed in Schedule ‘A’ Part – VI.
Lumpsum price worked out by the contractor for “SEWAGE DISPOSAL” as listed in Schedule ‘A’ Part – VII.
Lumpsum price worked out by the contractor for “GARBAGE BIN" as listed in Schedule ‘A’ Part- VIII.
Lumpsum price worked out by the contractor for “DEMOLITION AND DISMANTLING (B/R)” as listed in Schedule ‘A’ Part – IX.
Lumpsum price worked out by the contractor for “EXTERNAL WATER SUPPLY” as listed in Schedule ‘A’ Part – X.
Lumpsum price worked out by the contractor for “EXTERNAL ELECTRIC SUPPLY” as listed in Schedule ‘A’ Part – XI.
Lumpsum price worked out by the contractor for "WATER COOLER / DESERT COOLER" as listed in Schedule ‘A’ Part -XII .
Lumpsum price worked out by the contractor for “HOT WATER SUPPLY” as listed in Schedule ‘A’ Part – XIII.
Lumpsum price worked out by the contractor for “DEMOLITION AND DISMANTLING (E/M)” as listed in Schedule ‘A’ Part – XIV.
Sch 'A' Part - XV : Fittings / Fixtures & Misc items. INTERNAL WATER SUPPLY Supply and fix 15mm bore kitchen sink tap, brass chrome finish dual flow pattern with silicon black flexible hose swivel type complete all as specified and as directed.
Supply and fix 15mm bore washing machine tap, brass chrome for PPR pipe complete all as specified and as directed.
INTERNAL ELECTRIC SUPPLY Supply and Fix Decorative wall mounting with different finishes with borosil glass frosted & soda glass suitable for 7.5 W A60 LED Lamp with E27 base etc complete in all respect all as specified and as directed by engineer in charge
Supply and Fix Decorative, wall mounting, antique brass finish fixture with opal glass diffuser suitable for 7.5 W A60 LED filament lamp E27 base etc complete in all respect all as specified and as directed by engineer in charge
Supply and Fix Decorative, wall mounting, antique brass finish fixture with opal glass diffuser suitable for 7.5 W A60 LED filament lamp E27 base etc complete in all respect all as specified and as directed by engineer in charge
Supply and fix single phase Digital energy meter tamper proof, CL 1.0 AC, 240V, 50 Hz with LCD display. 5-30A (measures & Displays kWh, V, I, kw, PF, last month history of kWh & MD in kW) complete all as specified and as directed.
Supply, install, test and commissioning of wall mounted LT meter panel board, indoor type custom designed with separate compartments with hinged door for housing 10 Nos single phase SMART Meters including suitable arrangements for fixing on wall with suitable clamping arrangement, fabricated out of 2mm thick MS sheet, internally connected with suitable capacity of copper cable including making good the disturbed floor including the following accessories:- (i) Supply, Install, Testing and Commissioning of 'smart meters with prepaid metering facility, AC Single intergradation phase, two wire, 240V, 50 Hz, 10 to 60Amps all as per BIS 16444;2015 (reaffirmed 2020) with plug in type bi directional communication module (The plugin- Module shall be field swappable/ replaceable) suitable for integration with approved communication technology GPRS/RF/Hybrid(GPRS+RF) any other advanced technology as per CEA/TRAI regulations etc, easily adaptable for existing network interface and integration with advanced Metering infrastructure(AMI) including meter box of suitable size as per OEM complete in all respect all as specified and as directed by Engineer -in - charge (ii) Internal power & control wiring with suitable PVC insulated copper wire
EXTERNAL WATER SUPPLY Construction of Valve chamber having inner dimension 600x600x600 mm suitable for gate valve upto 50mm with PCC 1:4:8 type D2 for foundation, brick work wall in cement mortar (1:4), PCC 1:2:4 type B1 for copping, rendering plaster in CM 1:4, 15mm thick including provision of MS sheet top cover 3mm thick with brazing of MS flat of Size 25mm x 4mm at edges and in diagonal and angle iron base frame of 40 x 40 x 5mm painting with two coat of synthetic enamel paint over a coat of red oxide primer and locking arrangement including necessary excavation earth work complete all as specified and as directed.
EXTERNAL ELECTRIC SUPPLY Material and labour for road cutting /Hard standing for taking up or laying of LT UG Cable upto a depth of 15cm, after laying of cable well ramming to the excavated soil including repair the excavated portion of the road as existing or by providing suitable mixture of PCC complete all as specified and as directed.
Supply, install test and commission LT Panel board, TPN 415 Volts, 50 Hz, 200 Amps capacity, out door cubical type floor mounted, CPRI approved, factory made, totally enclosed, double door at front & rear side inclusive of necessary locking arrangement, dust and vermin proof, IP-54, fabricated out of CRCA sheet not less than 3.00 mm thick with 2mm thick for internal compartment duly powder coated fixed on angle iron pedestal made out of 40X40X5mm with cable chamber for incoming and outgoing connections with suitable glands and lugs comprising for the following accessories including necessary PCC foundation of minimum 0.35m height positioned and grouted with suitable nut, bolts, washers etc to the MC pedestal and connecting all incoming and out going cables all as specified and directed :-
(a) INCOMING:- MCCB 4 Pole,125 Amps, breaking capacity of 36 KA, (ATFM) - 1 No (b) OUTGOINGS:- (i) MCCB 4 Pole 63 Amps, breaking capacity of 27 KA, (ATFM) - 3 Nos (ii) MCCB, 4 pole 25 Amps, breaking capacity of 25KA, (FTFM), - 1 No (c) 200 Amps aluminium busbar for phase and neutral duly insulated with PVC sleeves RYB, mounted on heavy duty epoxy insulators in separate compartment - 01 Set (d) Digital multi function panel meter for measuring voltage, Amps and Frequency with suitable CTs and back up protection - 1 Nos (e) LED type Indication lamp 240 Volts Set of three - 1 Set
Supply and fix 4 Pole MCCB 160 Amp, 50 Hz, 415 V with rupturing capacity 36 KA complete in existing panel including providing necessary connection with suitable modification to the panel as required for fixing the MCCB complete all as specified and as directed.
WATER COOLER Supply and fix Electronic voltage stabilizer, automatic operation, single phase, naturally air cooled indoor wall mounting type & designed for input variation between 170V to 250V with output voltage stabilized at 230V with accuracy of +/- 2.5% and of capacity 2 KVA complete all as specified and as directed by Engineer-in-charge.
DESERT COOLER Supply and fix desert cooler electric driven (single phase), 230 volts 50Hz having nominal air flow capacity of 4000 Cum per hour Plastic/PVC Body 55 ltrs water capacity with honey comb cooling pads with water level indicator, speed control, ON/OFF switch all as specified and directed. Make : Symphony / Bajaj/ Usha/Voltas
MISC Supply and fix telephone socket RJ-45 & RJ-11(for Telephone / Data cable) complete all as specified and as directed.
DEMOLITION AND DISMANTLING (E/M) Taking down unserviceable Main Switch, Distribution Boards, Plug & socket DBs along with MCBs of any description complete all as specified and as directed.
Taking down carefully the energy meter of any description and depositing to MES Store Carefully complete all as specified and as directed.
Taking down old, vintage and unserviceable Earthing with connected accessories including earth work complete all as specified and as directed.
Taking down old, vintage and unserviceable aluminium / copper submain wiring of any size complete all as specified and as directed.
Taking up carefully LT UG cable of size 25 Sq mm 4 core from the trench/ laid on surface by removing the terminals from connected switchgears for re-laying the same including necessary earth work complete all as specified and as directed.
Taking up carefully LT UG cable of size 50 Sqmm 3 ½ core cable from the trench/ laid on surface by removing the terminals from connected switchgears for re-laying the same including necessary earth work complete all as specified and as directed.
Taking up carefully 50mm dia cast GI tubing pipes (including all fittings) from trench /laid on surface for relaying the same including necessary earth work complete all as specified and as directed.
Taking down old, rusted GI tubing of size 50 mm dia bore and crediting to contractor complete all as specified and as directed.
Taking down old, rusted GI tubing of size 20 mm dia bore and crediting to contractor complete all as specified and as directed.
Taking down old, rusted gate valve/Float valve of size 20 mm dia bore and crediting to contractor complete all as specified and as directed.
Taking down carefully the Geyser of capacity upto 25 Ltrs and any type by disconnecting all water and electrical connections, complete from its installed position and depositing to MES store carefully complete all as specified and as directed.
Taking down carefully the indoor and outdoor units of AC along with voltage stabilizer of split type air conditioner of capacity upto 2.0 TR by disconnecting all electrical connections, suction and discharge lines from its installed position and depositing to MES store carefully complete all as specified and as directed.
Indu Electricals (BID ID -3407585)
INDGUARD ENGINEERS (BID ID -3407955)
Sri Associates (BID ID -3407947)
B.N.S Constructions (BID ID -3408228)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .