Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.0 LAccepted-Finance | ₹28.0 L | L1 | Accepted-Finance Financial Bid Accepted |
| 2 | L2₹28.3 L+₹31,447 (1.12%)Accepted-Finance | ₹28.3 L+₹31,447 (1.12%) | L2 | Accepted-Finance Financial Bid Accepted |
| 3 | L3₹28.6 L+₹63,522 (2.27%)Accepted-Finance 11 C GROUND FLOOR DYADER ENCLAVE VIKAS NAGAR ITTAM NAGAR WEST DELHI 110059 | WEST | DELHI | 110059 | ₹28.6 L+₹63,522 (2.27%) | L3 | Accepted-Finance Financial Bid Accepted |
| 4 | L4₹29.2 L+₹1.2 L (4.33%)Accepted-Finance B 3 105 PASCHIM VIHAR NEW DELHI 110063 | WEST | DELHI | 110063 | ₹29.2 L+₹1.2 L (4.33%) | L4 | Accepted-Finance Financial Bid Accepted |
| 5 | L5₹30.0 L+₹2.0 L (7.18%)Accepted-Finance | ₹30.0 L+₹2.0 L (7.18%) | L5 | Accepted-Finance Financial Bid Accepted |
Tender Value
₹31.4 L
EMD Value
₹62,893
Closing Date
15 Apr 2026, 3:00 pmClosed
EE(E) HMED(N) PWD,
EE(E) HMED(N) PWD, Dr. BSA Hospital sec-6 ROhini Delhi-85.
Supplying Installation Testing commissioning of Split Window type energy efficient ACs for various locations in Dr BSA Hospital Rohini Delhi
2026_PWD_289583_1
04/EE(E)HMED(N)/PWD/BSAH/2026 27
Open Tender
Composite Works
Percentage
30 days
Dr. BSA Hospital Sec-6 Rohini Delhi
Please refer the tender Document as per NIT
10 documents required · 10 mandatory
₹0
₹62,893
25 Apr 2026
6 Apr 2026
15 Apr 2026
6 Apr 2026
15 Apr 2026
6 Apr 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Supplying, Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface/ concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 0C. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electrotechnical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS : 1391 Part II 2023. The system shall be able to operate up to 50 0C (out door ambient temperature). Inverter Type - Cooling only | |||||
| 1.01 | 1.5 TR with 5 Star BEE Rating | 37 | Each | - | - |
| 1.02 | 2.0 TR with 5 Star BEE Rating | 10 | Each | - | - |
| 2Supplying , Installation, Testing and Commissioning of Window type Air conditioners complete with copper power cable upto 3 Mtr, wireless Remote, suitable for working between 180- 260V with low & high voltage cutoff and 50 hz, 1 phase AC supply capable of performing, cooling, dehumidification, air circulation, R-32/R-410A /R-407B Green Refrigerant with Scroll / rotary compressor with min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB), antifreeze thermostat on the coil as a safety feature, complete with fixing including T&P & labour etc as required complete in all respect as specified of following capacity. Sound level of up to 50dB inside the room is acceptable. The unit shall be in confirmation with IS 1391 Part-I 2023 and CPWD Specification. The system shall be able to deliver 100% of the rated capacity upto 42 0C. The system shall be able to operate up to 50 0C (out door ambient temperature). Inverter Type | |||||
| 2.01 | 1.5 TR with Inverter 5 Star BEE rating | 8 | Each | - | - |
| 3 | SITC of hard drawn copper suction and discharge refrigeration pipe of size 5/8"and 3/8" suitable for 1.5/2.0TR duly insulated by nitrile rubber insulation i/c breezing of all the joints with necessary support as required as per site requirement. | 320 | P/Mtr | - | - |
| 4Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. | |||||
| 4.01 | 3 x 4 sq. mm | 200 | P/Mtr | - | - |
| 5 | Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V "C" curve DP MCB complete with connections, testing and commissioning etc. as required. | 55 | Each | - | - |
| 6 | P/F of PVC pipe of size 25 mm dia along with accessories and insulation for draining of condensate to a safer disposal point in recess / surface i/c the cutting the chase in the wall and making good the same with cement work etc complete as reqd. | 300 | P/Mtr | - | - |
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 3.30 MB
NIT.pdf
Tender Documents • 3.29 MB
BOQ_384598.xls
BOQ • 0.29 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .