Loading…
Loading…
| # | Company | Amount | Status |
|---|---|---|---|
| 1 | ₹14.7 LAWARDED | AWARDED |
Tender Value
₹18 L
EMD Value
₹37,493
Closing Date
18 Jul 2025, 10:30 pmClosed
Directorate of Municipal Administration
installation of transformer and other electrical accessories to solid waste management plant of hiriyur cmc
DMA/2025-26/EL/WORK_INDENT44371
DMA/2025-26/EL/WORK_INDENT44371
Open
Electrical
Two Tender Document System(Two Cover)
DMA City Municipal Council Hiriyur
₹500
₹37,493
3 Jul 2025
3 Jul 2025
19 Jul 2025
14 Jul 2025
installation of transformer and other electrical accessories to solid waste management plant of hiriyur cmc
Hydraulic Excavator of 1.1 m3 bucket vol 1 it no 50
Construction of Embankment by excavating the available approved Gravel/ Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading...
Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes...
Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up...
Providing 20 mm cement plaster of mix :1:6 (1 cement: 6 fine sand) to brick/stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, includi...
Distribution Transformer - 3 Phase, 11kV/433V - Stacked CRGO Core with Oil as per IS-1180 (Part-1): 2014 250 kVA, Aluminium Wdg, Star 2 (5 Star) vol 6 it no 12.08
Supplying fixing and wiring earth electrode for grounding of lifts, transformers, DG sets etc. using 40 mm dia 2.9 mm thick 2.5m long GI pipe with GI funnel with mesh and suitable size reducer fixed o...
GI/Copper strips for grounding connections, using necessary fixing materials as required GI/Copper strips 25 x 6 mm GI strip
GI/Copper strips for grounding connections, using necessary fixing materials as required GI/Copper strips 25 x 6 mm Copper strip
GI/Copper strips for grounding connections, using necessary fixing materials as required GI/Copper strips 600 x 600 x 3 mm Copper plate
11 kV, Special 3 Pin Cross Arm - GI
HT ST Support 50x8 mm Flat - GI
Spiral Earth Electrode
Anticlimbing Device GI Barbed wire (12 Mtr/Kg)
LT 4 Pin Cross Arm - GI
No. 8 Strain Insulator
RCC Pole Clamp - GI
11 kV GI Pin for 11 kV Ceramic Shell Insulator
DISC Insulator 45 kN Porcelain
(6/3.35 mm Al + 1/3.35 mm St), Std Wt: 214 Kg/KM
7/10 SWG Guy Wire
(7/3.251 mm Dia), Std Wt: 680 Kg/KM
PG Clamp Rabbit to Rabbit
9 kV, 5 kA Lightning Arrester Metal Oxide Ceramic type
with GROUND DISCONNECTOR
(Dwg No. BESCOM/GM/QS&S/26 Dtd 24.10.2007)
11 kV, HG Fuse Unit with Solid Core Insulator
(Dwg No. BESCOM/GM/QS&S/21 Dtd 24.11.2018)
11 kV, 200 Amps Single Break GOS
(Dwg No. BESCOM/GM/QS&S/23 Dtd 24.11.2018)
11 kV, DOLO Cutout Conventional to Erstwhile KEB
Transparent Alkathine tube 19 mm dia, 2 mm thick in
coils of 30 Mtr
Caution/Danger Board
Digging of Pit for GUY SET Hard Soil
Providing Spiral Earth Electrode type earthing (without
charcoal, salt etc.,)
Fixing DOLO Cutout/Horn Gap Fuse including fixing of cross arm and wiring
Fixing of GOS including wiring (11 kV Single Break 200
Erection of 200 - 250 kVA Transformer
Erection of HT metering Cubicle on Platform
11 kV, 3 Core, XPLE HTUG Cable with pressure extruded inner sheeth, ROUND WIRE ARMOURED as per IS-7098 (Part-2) Armouring wires dia and Resistivity as per
240 Sqmm, (55 GI Wires - 3.15 mm Dia)
Heat Shrinkable Indoor Type Cable Termination Kit
for XLPE Cable 3x95 Sqmm
Heat Shrinkable Outdoor Type Cable Termination
Kit for XLPE Cable 3x95 Sqmm
Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff HT Cable 3x95 to 150 Sqmm
Heavy Duty Copper Terminal Long Barrel
25 Sqmm Copper Terminal, Apprx Wt: 11 Gm
Heavy Duty Copper Terminal Long Barrel
50 Sqmm Copper Terminal, Apprx Wt: 26 Gm
Heavy Duty Copper Terminal Long Barrel
95 Sqmm Copper Terminal, Apprx Wt: 58 Gm
Heavy Duty Copper Terminal Long Barrel
120 Sqmm Copper Terminal, Apprx Wt: 64 Gm
Heavy Duty Copper Terminal Long Barrel
185 Sqmm Copper Terminal, Apprx Wt: 158 Gm
Brass Cable Gland 25
Brass Cable Gland 32
Brass Cable Gland 40
Route & Joint indicating slab with MS Anchor rod
Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff LT Cable 35 to 95 Sqmm
Supplying, fixing and wiring 50/5 to 400/5A 5VA burden Current Transformer Class 0.5 accuracy with Tape Wound.
Supplying and fixing Electronic Trivector Meter (ETV)suitable for operation LT operation and - CT operated meter in polycarbonate body in class0.5 accuracy as per IS 14697 and completely wired.
Supplying and fixing of Shunt trip suitable for MCCB.CBCT
Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage curr...
Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direct...
33 kV, 2500 A, 25 kA Outdoor Vacuum Circuit Breaker with terminal connector suitable for Al. tube/conductor and mounting structure etc., as per technical specification. Vol 6 it no 3.6
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .