| 1 | L1₹42.2 LAccepted-AOC HO SR NO 73 TAPKIR MALA CHOWK TAPKIR NAGAR KALEWADI PIMPRI PUNE 411017 | PUNE | MAHARASHTRA | 411017 | L1 | Accepted-AOC Lowest amount quoted | |
| 2 | L2₹49.9 L+₹5.8 L (13.3%)Rejected-Finance 1476 SARASWATI COLONY CHERITAL JABALPUR | JABALPUR | MADHYA PRADESH | 482001 | L2 | Rejected-Finance Second Lowest amount quoted | |
| 3 | L3₹52.4 L+₹8.3 L (18.9%)Rejected-Finance | L3 | Rejected-Finance Highest amount quoted |
Tender Value
₹47 L
EMD Value
₹94,000
Closing Date
17 Aug 2020, 6:00 pmClosed
Shri B M Verma, IDSE, EE(SG)
Garrison Engineer (East), Near COD Estate, Ranjhi, Jabalpur (MP)-482011
As per BOQ
2020_MES_361350_1
8259/E8
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
Garrison Engineer (East) Jabalpur
D b(i)
8 documents required · 8 mandatory
₹500
Garrison Engineer (East) Jabalpur
₹94,000
Yes
3 Oct 2020
16 Jul 2020
19 Aug 2020
16 Jul 2020
17 Aug 2020
31 Jul 2020
16 Jul 2020 - 30 Jul 2020
Amount
Comprehensive maintenance of DG set including routing/preventive maintenance checks at least once in a month, checking up of engine and alternator for trouble free functioning and attending break downs/complaints as and when required. The type of work / maintenance services to be carried out during comprehensive maintenance are as under :- (a) Checking of Engine Oil level. (b) Checking of oil bath cleaner oil level. (c) Drain sediments from fuel tank. (d) Checking of pre- cleaner dust pan. (e) Checking of air cleaner restriction. (f) Checking of coolant level. (g) Record Oil pressure (h) Checking/tightening of all nuts/bolts of engine and alternator. (i) Checking of AVM pads. (k) Checking of diaphragm coupling (l) Checking of tappet clearance m) Clean fuel tank breather (m) Clean crank case breather (n) Checking of Air piping. (o) Cleaning of oil bath Air cleaner Tray screen. (p) Check / adjust Belts. (q) Checking battery voltage, water level and apply jelly on terminals.(r) Checking fan hub/air blower hub and water pump. (s) Cleaning turbo charger. (t) Tighten manifold Nuts of cops screws. (u) Cleaning of electrical connections with CTC solution. (v) Checking of safety controls (w) Cleaning of cooling system/radiator assembly (x) Cleaning of Engine and radiator assy (y) Checking of Engine Oil Level. The capacity and location of the DG sets that are included in the comprehensive maint are as under :- Note : - (i)The comprehensive maintenance includes carrying out preventive maintenance excluding replacing all the unserviceable / worn out spares to keep the DG set for trouble free functioning. (ii) The rate quoted deemed to be included all the minor spares such as screws, clips washers , distilled water, electrolite etc and other spare parts shall be measured and paid separately under respective items. (iii) Make and Specification of spare parts of DG Sets as per existing make/specification.
ditto all as per item No 1 above for 320 KVA Capacity Make Kirloskar,Installed at 506 ABW
ditto all as per item No 1 above for 200 KVA Capacity Make Kirloskar,Installed at 506 ABW, Power House & Main pump house
ditto all as per item No 1 above for 160 KVA Capacity Make Kirloskar,Installed at Main power house
ditto all as per item No 1 above for 100 KVA Capacity Make Kirloskar,Installed at 506 ABW SOLMEM & Tool Room,
ditto all as per item No 1 above for 75 KVA capacity, Make Kirloskar, installed at Rawalson Pump House and at 37 Borewell Pump House
ditto all as per item No 1 above for 63 KVA capacity, Make Kirloskar, installed at Depot Regt, MAG 21 ASD, MAG 8, 506 ABW near QM office and borewell No 16
ditto all as per item No 1 above for 40 KVA capacity, Make Kirloskar, 506 ABW, COD Computer Centre, GE Office and 120 OR 506 ABW
ditto all as per item No 1 above for 30 KVA capacity, Make Kirloskar, installed at ASD Main gate
ditto all as per item No 1 above for 7.5 KVA capacity, Make Kirloskar, installed at Exchange COD
S&F in repairs set of fuel pre-filters and fine-filters as per sample and make for the following capacities of DG sets. Each set shall be comprising complete set of pre/fine filters.
ditto all as per item No 11 above for 320 KVA Capacity, Make Kirloskar
ditto all as per item No 11 above for 200 KVA Capacity, Make Kirloskar
ditto all as per item No 11 above for 160 KVA Capacity, Make Kirloskar
ditto all as per item No 11 above for 100 KVA capacity, Make Kirloskar
ditto all as per item No 11 above for 63 KVA capacity, Make Kirloskar.
ditto all as per item No 11 above for 40 KVA capacity ,Make Kirloskar.
ditto all as per item No 11 above for 30 KVA capacity ,Make Kirloskar.
ditto all as per item No 11 above for 7.5 KVA capacity ,Make Kirloskar.
S&F in repairs set of lube/engine oil filters / catridges as per sample and make for the following capacities of DG sets. Each set shall be comprising complete set of tube/engine oil filter
ditto all as per item No 20 above for 320 KVA Capacity, Make Kirloskar
ditto all as per item No 20 above for 200 KVA Capacity, Make Kirloskar
ditto all as per item No 20 above for 160 KVA Capacity, Make Kirloskar
ditto all as per item No 20 above for 100 KVA capacity, make Kirloskar
ditto all as per item No 20 above for 63 KVA capacity ,make Kirloskar.
ditto all as per item No 20 above for 40 KVA capacity ,make Kirloskar.
ditto all as per item No 20 above for 30 KVA capacity ,make Kirloskar.
ditto all as per item No 20 above for 7.5 KVA capacity ,make Kirloskar.
S&F in repairs battery lead with stranded copper conductor of size 95 /70sqmm single core PVC insulated, flexible.
S&F in repairs V- belt for fan A 56/A55/B47.
S&F in repairs stopping solenoid coil 12V for 320/200/160/125/110/75/63/50/30 KVA DG set.
S&F in repairs off solenoid coil 12V for 50/75/110 KVA push on type ( for double Tank DG set).
S&F in repairs battery terminals of copper.
S&F in repairs Benjo bolts .
S&F in repairs fuel pipe filter to FIP wire braided.
S&F in repairs fuel pipe (rubber pipe ) upto 15 mm size from fuel tank to the DG set & over flow return complete all as specified
S&F in repairs carbon brush suitable for 320/200/160/125/110/75/63/50KVA Gen Set.
S&F in replacement anti vibration mounting pad suitable for 320/200/160/125/110/75/50 KVA for the DG set .
S&Fin repairs gate valve 15 mm bore cast copper alloy for the fuel tank out let.
S&F in replacement water outlet and inlet hose pipe from radiator to Engine and back Engine to radiator
S&F in repairs lubricant oil pipe.
S&F in repairs anti vibration rubber pad for side radiator.
S&F in repairs DC ammeter 12 V of range (-) 30- 0- (+)30 A .
S&F in repairs lubricant oil pressure guage 0 to 10 kg / sq cm.
S&F in repairs maintenance free power pack unit 24 volt, diamension 430x255x235mm suitable for generating set 160 KVA to 500KVA, Make : EXIDE/ AMARON/ LUMINOUS
S&F in repairs maintenance free power pack unit 12 volt, diamension 355x175/x235 mm suitable for generating set 30 KVA to 125 KVA, Make : EXIDE/ AMARON/ LUMINOUS
Reconditioning of lead acid batteries of which cells have been got short circuited including replacement of both the poles of capacity 180 AH
Repairing the self starter of Mico make after removing from the Gen set of capacity 110/75/63 KVA and transporting to an authorised sevice centre and vice versa complete all as specified. Note:- Replacement of the following U/S parts shall be measured and paid separately under relevent items:-
Armature - 1 Nos
Bendex of suitable size-1 nos
Bearing / bush -1 sets
Relay switch of suitable size-1 nos
Repairing the self starter of Mico make after removing from the Gen set of capacity 40 KVA and transporting to an authorised sevice centre and vice versa complete all as specified. Note:- Replacement of the following U/S parts shall be measured and paid separately under relevent items:-
Armature - 1 Nos
Bendex of suitable size-1 nos
Bearing / bush -1 sets
Relay switch of suitable size-1 nos
Supply only A series electronic timers on delay function model A1D1 / AIDCS ,12 V DC, with time range 0.3S to 30Min. Make EAPL suitable for AMF panel.
Supply only B series electronics timers model B1DCA-X adjustable cyclic fuction 240V AC suitable for AMF panel.
Supply only relay 12 V DC , Make PLA, 8/11 pins suitable for AMF panel Make : L&T/ Schneider/ Havells
Supply only indicator lamps DC filament type 10 W ,12 V .Make : L&T/ Schneider/ Havells
Supply only indicator lamps AC 230 V, LED type for the panel boards. Make : L&T/ Schneider/ Havells
Supply only push builtin with contact element 5A. Make : L&T/ Schneider/ Havells
Supply only Current Transformer as required for the Gen/ AMF panel Make : L&T/ Schneider/ Havells
Supply only Ameter of range 100 Amps as required for the Gen/ AMF panel. Make : L&T/ Schneider/ Havells
Supply only Volt meter 0 to 600 V range suitable for the Gen/ AMF panel. Make : L&T/ Schneider/ Havells
Supply only frequency meter 45 to 60 Hz range suitable for theGen/ AMF panel. Make : L&T/ Schneider/ Havells
Supply only PVC connector heavy duty 12 way, 100 A suitable for AMF panel. Make : L&T/ Schneider/ Havells
Dismantling Unservicable contactor of capacity ML 1.5 to ML 4 and mnx80A
S&F main contactor L&T, MN X80A, 3 pole suitable for AMF panel. Make : L&T/ Schneider/ Havells
S&F main contactor, ABB CAS 22 E-1 ,3 pole suitable for AMF panel. Make : L&T/ Schneider/ Havells
S&F main contactor L&T, ML 1.5, 3 pole suitable for AMF panel. Make : L&T/ Schneider/ Havells
S&F main contactor L&T, ML 2, 3 pole suitable for AMF panel. Make : L&T/ Schneider/ Havells
S&F main contactor L&T, ML 3, 3 pole suitable for AMF panel. Make : L&T/ Schneider/ Havells
S&F main contactor L&T, ML 4, 3 pole suitable for AMF panel. Make : L&T/ Schneider/ Havells
S&F repairs auxiliary contactor of suitable size for AMF panel. Make : L&T/ Schneider/ Havells
Drain out the out lived engine oil, clean the oil sump and and supply and filling the engine oil as recommended by manufacturer of DG Set all as directed.
Providing aluminium cladding to the exhaust pipe and silencer of the DG sets of any capacity by engaging highly skilled technicians after removing the existing totally worn out asbestos rope ( wherever available) and prepairing the surface , applying one coat of red oxide primer and including 50mm thick high quality glass wool thermal insulator packing which is bidinding tightly with chicken wiremesh of approved quality to the exhaust pipe and neatly finishing sealing with 24 SWG aluminium sheet all as directed by Engr -in- charge.
M&L for replacing the unserviceable stop solenoid coil suitable for 110 /125/63/50 KVA Gen Set.
Opening the coupling , dismantling the alternator carefully removing the fly wheel dismantling the unserviceable starting gear wheel , supply and fixing new starting gear wheel, fixing back the alternator and properly coupled back all as directed including servicing the 110/125/50 KVA Gen Set complete all as specified.
Opening the coupling , dismantling the alternator carefully removing the fly wheel dismantling the unserviceable starting gear wheel , supply and fixing new starting gear wheel, fixing back the alternator and properly coupled back all as directed including servicing the 40 KVA Gen Set complete all as specified.
Dismantling/ taking down Unservicable onload change over switch capacity 125 Amp to 630 Amp
S&F On load change over switch 4 pole 630 Amps with sheet metal enclosure, Make : L&T/ Schneider/ Havells
S&F On load change over switch 4 pole 400 Amps with sheet metal enclosure, Make : L&T/ Schneider/ Havells
S&F On load change over switch 4 pole 320 Amps with sheet metal enclosure, Make : L&T/ Schneider/ Havells
S&F On load change over switch 4 pole 250 Amps with sheet metal enclosure, Make : L&T/ Schneider/ Havells
S&F On load change over switch 4 pole 200 Amps with sheet metal enclosure, Make : L&T/ Schneider/ Havells
S&F On load change over switch 4 pole 160 Amps with sheet metal enclosure, Make : L&T/ Schneider/ Havells
S&F On load change over switch 4 pole 125 Amps with sheet metal enclosure, Make : L&T/ Schneider/ Havells
Dismantling Unservicable MCCB capacity 100 Amp to 630 Amp.
S&F MCCB 630Amps, 36 KA,4 POLE ,(with Adjustable microprocessor released) Make : L&T/ Schneider/ Havells
S&F MCCB 400 Amps, 36 KA,4 POLE ,(with Adjustable microprocessor released) Make : L&T/ Schneider/ Havells
S&F MCCB 320Amps, 36 KA,4 POLE ,(with Adjustable microprocessor released) Make : L&T/ Schneider/ Havells
S&F MCCB 250Amps, 35 KA,4 POLE ,(with Adjustable microprocessor released) Make : L&T/ Schneider/ Havells
S&F MCCB 200Amps, 35 KA,4 POLE (with Adjustable microprocessor released) Make : L&T/ Schneider/ Havells
S&F MCCB 160Amps, 35 KA,4 POLE ,(with Adjustable microprocessor released) Make : L&T/ Schneider/ Havells
S&F MCCB 125Amps, 25 KA,4 POLE ,(with Adjustable microprocessor released) Make : L&T/ Schneider/ Havells
S&F MCCB 100Amps, 25 KA,4 POLE ,(with Adjustable microprocessor released) Make : L&T/ Schneider/ Havells
S&F MCCB 250Amps, 35 KA, 3 POLE ,(with Adjustable microprocessor released)Make : L&T/ Schneider/ Havells
S&F MCCB 200Amps, 35 KA, 3 POLE (with Adjustable microprocessor released) Make : L&T/ Schneider/ Havells
S&F MCCB 160Amps, 35 KA, 3 POLE ,(with Adjustable microprocessor released) Make : L&T/ Schneider/ Havells
S&F MCCB 125Amps, 25 KA, 3 POLE ,(with Adjustable microprocessor released) Make : L&T/ Schneider/ Havells
S&F MCCB 100Amps, 25 KA, 3 POLE ,(with Adjustable microprocessor released) Make : L&T/ Schneider/ Havells
Dismantling/taking down UNSV Switch fuse unit of capacity 200Amp to 32 Amp of any size.
SUPPLY & FIX TPN switch fuse unit with HRC fuse 200 amp, double break heavy duty, Make : L&T/ Schneider/ Havells
SUPPLY & FIX TPN switch fuse unit with HRC fuse 160 amp,double break heavy duty, Make : L&T/ Schneider/ Havells
SUPPLY & FIX TPN switch fuse unit with HRC fuse 63 amp, double break heavy duty, Make : L&T/ Schneider/ Havells
SUPPLY & FIX TPN switch fuse unit with HRC fuse 32 amp, heavy duty, Make : L&T/ Schneider/ Havells
S&F in repairs multi functional meter confirming to quasar class 3 Phase 4W IPM 240V line to earth 5A, CL1 Make : L&T/Legrand/Schneider
S&F in repairs over load relay range 45-75 Amp for Power Contactor MNX80, Make : L&T/ Schneider/ Havells
S&F in repairs DC Ralay for AMF Panel Make : L&T/ Schneider/ Havells
S&F in repairs Battery 12 volt 180 AH Make : Exide/ Amaron/ Luminous
S&F in repairs automatic voltage regulator electronic static type suitable for DG set of upto 125 KVA 3 Phase 415 Volts
Earthing complete with galvanized steel earth plate electrode 600mm x600 mm x 6mm buried directly in ground vertically to a depth not less then 2.25 meter below normal ground level with top edge of the plate not less then 1.50 meter below normal ground level connected to galvanized earth wire 4.00mmdia by means of bolts ,nuts ,check nuts and washers complete up to and including test point made out of 40 x 6mm alum flat including earthing pit , charcoal common salt ,Earthing lead 4.00mm dia up to 7.5m, 20mm dia medium grade GI watering pipe ,G.I. protection pipe 15 mm dia up to 7.5m long,,PPC pit in PCC 1:2:4 type B-1 using 20 mm graded stone aggregate ,PCC pit cover including earth work complete all as shown in electrical plate No-5 of SSR-1991 (part-I)
Comprehensive maintenance of DG set including routing/preventive maintenance checks at least once in a month, checking up of engine and alternator for trouble free functioning and attending break downs/complaints as and when required. The type of work / maintenance services to be carried out during comprehensive maintenance are as under :- for 750 KVA DG SET (11000 VOLT) (a) Checking of Engine Oil level. (b) Checking of oil bath cleaner oil level. (c) Drain sediments from fuel tank. (d) Checking of pre-cleaner dust pan. (e) Checking of air cleaner restriction. (f) Checking of coolant level. (g) Record Oil pressure (h) Checking/tightenig of all nuts/bolts of engine and alternator. (i) Checking of engine oil level (j) Checking of AVM pads. (k) Checking of diaphragm coupling (l) Checking of tappet clearance (m) Clean fuel tank breather (n) Clean crank case breather (o) Checking of Air piping. (p) Cleaning of oil bath Air cleaner Tray screen. (q) Check / adjust Belts. (r) Checking battery voltage, water level and apply jelly on terminals.(s) Checking fan hub/air blower hub and water pump. (t) Cleaning turbo charger. (u) Tighten manifold Nuts of cops screws. (v) Cleaning of electrical connections with CTC solution. (w) Checking of safety controls (x) Cleaning of cooling system/radiator assembly (y) Cleaning of Engine and radiator assy. The capacity and location of the DG sets that are included in the comprehensive maint are as under :- Note : - (i)The comprehensive maintenance includes carrying out preventive maintenance including replacing all the unserviceable / worn out spares to keep the DG set for trouble free functioning. (ii) The rate quoted deemed to be included all the minor spares such as screws, clips washers , distilled water, electrolite etc and other spare parts shall be measured and paid separately as supply only under respective items. (iii) Make and specification of spare parts of DG Sets as per existing make/specification
Comprehensive maintenance of DG set alternator including routing / preventive maintenance checks , checking up of alternator for trouble free functioning and attending break downs/ complaints as and when required. The type of work / maintenance services to be carried out during comprehensive maintenance are as under :- for 750 KVA DG SET (11000 VOLT) Note for item No 117 & 118 above : - (i) Maintenance/servicing & B, C & D checks (Norms of DG Set/Alternator as per maintenance manual) shall be carried out through OEM (Original Equipment Manufacturer) only (ii) The rate quoted deemed to be included all the minor spares as per OEM (Original Equipment Manufacturer) recommendation and other spares will be measured and paid separately under relavant items. (iii) Engine Oil will be issued under schedule B if required
S&F in repairs ELEMENT LUBE OIL FILTER as per Cat No.KIT3238204 and Make Kirloskar, Model No- KTA 38 G, 750 KVA Capacity complete all as specified.
S&F in repairs set of KIT FUAL FILTER & RING as per Cat No KIT3238493 and Make Kirloskar, Model No- KTA 38 G, 750 KVA Capacity complete all as specified.
S&F in repairs KIT BYPASS FILTER ELEMENT KIT BYPASS FILTER ELEMENT as per Cat No KIT3879488 and Make Kirloskar, Model No- KTA 38 G, 750 KVA Capacity complete all as specified.
S&F in repairs ELEMENT AIRCLEANER- 1 as per Cat No 4020551 and Make Kirloskar, Model No- KTA 38 G, 750 KVA Capacity complete all as specified.
S&F in repairs ELEMENT AIRCLEANER- 2 as per Cat No 4020551 and Make Kirloskar, Model No- KTA 38 G, 750 KVA Capacity complete all as specified.
S&F in repairs SOLENOID as per Cat No 3054709 and Make Kirloskar, Model No- KTA 38 G, 750 KVA Capacity complete all as specified.
S&F in repairs V BELT RIBBED as per Cat No 4958411 and Make Kirloskar, Model No- KTA 38 G, 750 KVA Capacity complete all as specified.
S&F in repairs VALVOLINE PREMIUM BLUE 7600 1/55LTR as per Cat No 500258 and Make Kirloskar, Model No- KTA 38, 750 KVA Capacity complete all as specified.
Repairing the self starter of Mico make after removing from the Gen set of capacity 750 KVA and transporting to an authorised sevice centre including replacement of the following U/S parts:-
a) Armature . Qty : 1 No
b) Bendex of suitable size : 1 No
c) Bearing/bushes : 1 set
d) Relay switch of suitable size : 1 No
Repairing the Dynamo/Alternator of Mico make after removing from the Gen set of capacity 750 KVA and transporting to an authorised sevice centre including replacement of the following U/S parts:-
a) Armature of suitable size : 1 No
b) Bearings / bushes of suitable size : 1 Set
c) Voltage regulator of suitable size : 1 set
Opening the coupling, dismantling the alternator carefully removing the fly wheel dismantling the unserviceable starting gear wheel, including minor repairs and cutting welding (if required) and transporting to authorised service centre fixing back the alternator after repair and properly coupled back all as directed including installation, testing & commissioning after repair of 50/63/125 KVA Gen Set complete all as specified.
M&L for rewiding the alternator (starter & rotor) with super enamelled copper winding wire with appropriate same gauge of existing coil with similar class of existing insulation as recommended by manuracturer with high quality normex insulating paper applying best quality insulating varnish on starter/rotor windings drying them completely, testing the insulations as directed by Engr-in-Charge complete all as specified.
Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendents, regulators, sockets etc and making good disturbed surfaces of walls, floors, as per existing finishes etc complete all as specified.
Taking down carefully unserviceable/partly unserviceable light fittings any type, tube light fittings and fixtures, etc, and making good to the disturbed surfaces of walls/floor etc to macth with existing surfaces including white washing/colour washing/distempering to match with existing wall/floor/ceiling finishes complete all as specified and directed.
Dismantling unserviceable main switch/ kitkat DBs/ MCB including wooden board from existing position and making good disturbed surfaces of wall to match with existing surfaces
Taking down sub main wiring without conduit of any size/capacity complete all as specified and making good disturbed sufaces to match with the existing surfaces.
M&L for the following Modular point wiring with PVC insulated unsheathed stranded copper conductor cable of size 1.5 Sq mm (FRLS), with PVC insulated unsheathed stranded copper conductor cable of size 1.5 Sq mm (FRLS) stranded for earth continuity wire, to be drawn in and including, PVC medium grade conduit not less then 20 mm dia with MS sheet metal sunken switch/Terminal box 1.2 mm thick and hylam switch board cover 3.0 mm thick or PVC moulded switch board and brass screws with cup washers including all necessary wall cutting and making good disturbed surface all as directed and specified Make of cable - FINOLEX / PLAZA / HAVELLS/POLYCAB & Make of PVC conduit & conduit accessories - PLAZA / FINOLEX/ KALINGA. Note : (i) Making good to match with the adjoining surface shall be included in the quoted rate. (ii) Rate shall be included for Cutting/chases of wall/floor/ceiling
-ditto- all as per item No 142 above but One light point controlled by one way switch
-ditto- all as per item No 142 above but One ceiling /exhaust fan point controlled by one switch and regulator
-ditto- all as per item No 142 above but One 3 pin 5 amp socket out point on the same board with other switches.
-ditto- all as per item No 142 above but One 3 pin 5 amps socket out let point on independent board
-ditto- all as per item No 142 above but One bell/buzzer point controlled by one bell push.
-ditto- all as per item No 142 above but One light point controlled by two 2-way switches
-ditto- all as per item No 142 above but for one socket outlet 15 Amp on independent board with 2.5 Sqmm (FRLS) cable and 1.5 Sqmm (FRLS) earth wire.
S&F Modular Switch piano flush type single pole one way 5 amps. Make : Havells/Anchor/ Leader
S&F Modular Switch piano flush type single pole one way 15 amps. Make : Havells/Anchor/ Leader
S&F Modular Switch piano flush button type two ways 5 Amps. Make : Havells/Anchor/ Leader
S&F Modular Socket out let 2 in one, 5/3 pin 5 Amp. Make : Havells/Anchor/Leader
S&F Modular Socket out let 2 in one, 5/3 pin 15 Amp. Make : Havells/Anchor/Leader
S&F Ceiling rose, surface bakelite 65x50 mm three terminal complete all as specified Make : Havells/ Anchor/Leader
S&F Modular Call bell AC-230 Volt single pole ding dong Make : Havells/Anchor/Leader
S&F Modular electronic regulator step type 100/120 watt 5 step complete all as specified and directed Make : Havells/Anchor/Leader
S&F Lamp holder insulated body with back plate for angle holder all as per specified Make : Havells/Anchor/Leader
S &F LED tube light fittings decorative ultra slim linear fixture with extruded alluminium heat sink envioromentel friendly Energy efficient ready to use pack, 1x18/20 Watt, 4 feet, surface mounting type extruded pvc, snap on installers and domestic electronic Driver, connector block etc.with all accessories internal prewired & includingconeecting up with 2 core flexible cppper conductor cable with sutable size & suitable for and mounting clamps PVC squre box 75x75mm - 2 nos. make- Bajaj/Crompton /Havells/Philips
S&F LED light fittings decorative 36/34 Watt recess mounting 2'x2' type extruded metal/aluminium body, and electronic LED driver, connector block etc. with all accessories internal prewired & including connecting up with 2 core flexible copper conductor cable with suitable size and mounting clamps etc complete all as specified and directed. Make-BAJAJ / HAVELLS/ CROMPTON/Philips
S&F Surface mounting round, decorative LED down lighter 10-12 WATT and transulent defuser, prefixed with flat profile and mounting clamps etc., complete all as specified Make BAJAJ Cat No BGSLO Sleek surface 12 WHRD/ Philips Cat No DN170CLED 10S-6500PSUWH /HAVELLS Cat No LHEAAGP7IA2W012/ CROMPTON Cat No LCDSPL-R-12-CDL
Taking down old street light fittings and Supply and fix LED security light fitting of 30 watt, aluminium pressure dia cast IP 66 with high power LED & LED driver of make CROMPTON / Philips/Havells/BAJAJ
S&F in repairs GI pipe 'light grade' bracket 25mm dia- 0.9m long & 2 set of clamps made out of 30x5mm MS flat & fixed with anchor bolt suitable for 2x11W security light fitting complete all as specified and directed
S&F in repairs earth enclosure with 2 pin earth plug socket complete with MCB SP 20/25 Amp,flush mounting type Make - LEGRAND/ABB/L&T
Taking down ceiling Fan/Exhaust Fan of any size or make complete all as specified and directed
Hanging only ceiling fan of 1200mm/1400mm/1500mm during wiring Sweep by providing fan hooks in proper manner and making connection with 3 core copper cable including painting all as per specified and directed by Engr-in-Charge.
Fixing only Exhaust fan 230/250/300/380/450 sweep heavy duty including 3 core copper cable & cutting holes if required etc. complete all as specified.
S&F in repairs capacitor 2.5/4 mfd suitable for ceiling fan/exhaust fan complete all as specified.
S&F in repairs PVC rectangular block of size 100 x100 x50mm for mounting switches, sockets/fan Reg, etc with 3mm thick plastic laminated sheet cover. Make : Anchor/Press fit/Havells/C&S
S&F in repairs PVC rectangular block of size 175 x100 x50mm for mounting switches, sockets/fan Reg, etc with 3mm thick plastic laminated sheet cover Make : Anchor/Press fit/Havells/C&S
S&F in repairs PVC rectangular block of size 200 x150 x50mm for mounting switches, sockets/fan Reg, etc with 3mm thick plastic laminated sheet cover. Make : Anchor/Press fit/Havells/C&S
S&F in repairs PVC rectangular block of size 250 x200 x50mm for mounting switches, sockets/fan Regulator etc with 3mm thick plastic laminated sheet cover. Make : Anchor/Press fit/Havells/C&S
S&F in repairs PVC rectangular block of size 350 x300 x50mm for mounting switches, sockets/fan Reg, etc with 3mm thick plastic laminated sheet cover. Make : Anchor/Press fit/Havells/C&S
S&F MCCB DB vertical type made of sheet steel , powder painted with nuetral bus bar 200 A, neutral link, IP-43-IK09 protection grade , 415Volts TPN with 4 ways Double door , MAKE - L&T CAT NO-DBVTL004DD/ LEGRAND CAT NO-607913/ Schneider
S&F MCB DB made of sheet steel , powder painted with neutral bus bar 200 A, neutral link, IP-43-IK09 protection grade , 415Volts TPN with 4 ways Double door, Make -L&T CAT NO-DBTPE004DD/ LEGRAND CAT NO-607715/ SCHNEIDER
S&F MCB DB made of sheet steel , powder painted with nuetral bus bar 200 A, neutral link, earth bar and Din rail ,230 Volts SPN with 8 ways Double door , IP-43-IK09 protection grade, Make -L&T CAT NO-DBSPN008DD/ LEGRAND CAT NO-607711/ SCHNEIDER
S&F MCB DB made of sheet steel , powder painted with nuetral bus bar 200 A, neutral link, earth bar and Din rail , 230 Volts SPN with 12 ways Double door IP-43-IK09 protection grade, Make -L&T CAT NO-DBSPN012DD/ LEGRAND CAT NO-607712/ SCHNEIDER
NOTE FOR ITEM Nos 172 to 175 -(i).The unit rate includes for cutting the brick walls to accommodate DB to make flush to wall/DB to be fixed on wall including frame made out of MS flat 40x5mm (ii).The unit rate includes for making good the disturbed surfaces including finishes to match with the adjoining surface. (iii) MAKE OF DB & MCB L&T/LEGRAND/ SCHNEIDER
S&F in repairs MCB TPN 415 Volts, 'C' series, breaking capacity 10 KA of rating 63Amps complete all as specified Make -L&T/LEGRAND/SCHNEIDER
S&F in repairs MCB SPN 240 Volts, 'C' series, breaking capacity 10 KA of rating 63Amps complete all as specified Make -L&T/LEGRAND/SCHNEIDER
S&F in repairs MCB SPN 240 Volts, 'C' series, breaking capacity 10 KA of rating 6-32Amps complete all as specified Make -L&T/LEGRAND/SCHNEIDER
S&F in repairs MCB SP 6-32 Amps 'C' series, breaking capacity 10 KA of rating complete all as specified Make -L&T/LEGRAND/SCHNEIDER
S&F in repairs MCCB TPN 63 Amps , 415Volts, 25KA ,4 Pole L&T CAT No-SL98603OOOO/ LEGRAND CAT NO-420053 / SCHNEIDER
S&F in repairs MCCB TPN 100 Amps , 415Volts, 25KA ,4 Pole L&T CAT No-SL98605OOOO/ LEGRAND CAT NO-420055 / SCHNEIDER
M&L for Sub main wiring power/circuit using PVC insulated unsheathed, stranded copper conductor cable 2 Single core of size 2.5 Sqmm (FRLS), earth continuity conductor of size 1.5 Sqmm (FRLS) to be drawn through in and including non metallic PVC conduit medium grade 20 mm dia with fittings (ISI marked) fixed on walls/roof/floors all as directed by Engineer in Charge.Notes:- (i)Two wires of 2.5 sqmm and one wire of 1.5 sqmm and PVC conduit shall be measured as one unit.
M&L for Sub main wiring power/circuit using PVC insulated unsheathed, stranded copper conductor cable 2 Single core of size 4 Sqmm (FRLS), earth continuity conductor of size 2.5 Sqmm (FRLS) to be drawn through in and including non metallic PVC conduit medium grade 25 mm dia with fittings (ISI marked) fixed on walls/roof/floors all as directed by Engineer in Charge. Notes:- Two wires of 4 sqmm and one wire of 2.5 sqmm & PVC conduit shall be measured as one unit.
M&L for Sub main wiring power/circuit using PVC insulated unsheathed, stranded copper conductor cable 2 Single core of size 6 Sqmm (FRLS), earth continuity conductor of size 4 Sqmm (FRLS) to be drawn through in and including non metallic PVC conduit medium grade 25 mm dia with fittings (ISI marked) fixed on walls/roof/floors all as directed by Engineer in Charge.Notes:- (i)Two wires of 6 sqmm and one wire of 4 sqmm & PVC conduit shall be measured as one unit.
M&L for Sub main wiring power/circuit using PVC insulated unsheathed, stranded copper conductor cable 2 Single core of size 10 Sqmm (FRLS), earth continuity conductor of size 6 Sqmm (FRLS) to be drawn through in and including non metallic PVC conduit medium grade 50 mm dia with fittings (ISI marked) on walls/roof/floors all as directed by Engineer in Charge.Notes:- (i) Two wires of 10sqmm and one wire of 6 sqmm & PVC conduit shall be measured as one unit.
Supply & Fix in repairs LED bulb of 7 Watt make of bajaj / crompton / Philips / Wipro
Supply & Fix in repairs LED bulb of 9 Watt make of bajaj / crompton / Philips / Wipro
Supply & Fix in repairs LED bulb of 11 Wattmake of bajaj / crompton / Philips / Wipro
Supply & Fix in repairs LED bulb of 15 Watt make of bajaj / crompton / Philips / Wipro
S&F in repairs LED tube light fittings decorative ultra slim linear fixture with extruded alluminium heat sink envioromentel friendly Energy efficient ready to use pack, 1x18/20 Watt, 4 feet, surface mounting type extruded pvc, snap on installers and domestic electronic Driver, connector block etc.with all accessories internal prewired & includingconeecting up with 2 core flexible cppper conductor cable with sutable size & suitable for and mounting clamps PVC squre box 75x75mm - 2 nos. make- Bajaj/Crompton /Havells/Philips
Supply and hanging ceiling fan BEE 5 star rating labled with double ball bearing 1200 mm Sweep 220 volt AC 50 HZ along with down rod , canopy and all accessories as supplied by manfacturer and making necessery electrical connection complete all as directed by Engr-in -charge.(BER Against convening order No- 3020/ EM/ 94/ E-3 dt 20 may 2019)
S&F in repairs Modular Switch piano flush type single pole one way 5 amps. Make : Havells/Anchor/ Leader
S&F in repairs Modular Switch piano flush type single pole one way 15 amps. Make : Havells/ Anchor/ Leader
S&F in repairs Modular Socket out let 2 in one, 5/3 pin 5 Amp. Make : Havells/Anchor/Leader
S&F in repairs Modular Socket out let 2 in one, 5/3 pin 15 Amp. Make : Havells/Anchor/Leader
S&F in repairs Modular Ceiling rose, surface bakelite 65x50 mm three terminal complete all as specified Make : Havells/Anchor/Leader
S&F in repairs Call bell AC-230 Volt single pole ding dong Make : Havells/Anchor/Leader
S &F in repairs Modular Bell push, flush type 5 Amps. Make : Havells/Anchor/Leader
S&F in repairs Modular electronic regulator step type 100/120 watt 5 step complete all as specified and directed Make : Havells/Anchor/Leader
S&F in repairs electronic regulator step type 100/120 watt (Mini type) complete all as specified and directed Make : Havells/Anchor/Leader
S&F in repairs electronic regulator step type 100/120 watt (Deluxe type) complete all as specified and directed Make : Havells/Anchor/Leader
S&F in repairs Lamp holder insulated body with back plate for angle holder all as per specified Make : Havells/Anchor/Leader
S&F in repairs Switch piano flush type single pole one way 5 amps. Make : Havells/ Anchor/ Leader
S&F in repairs Socket out let 2 in one, 5/3 pin 5 Amp. Make : Havells/Anchor/Leader
S&F in repairs Switch socket combination 5 Amps 5 pin flush type Make : Havells/ Anchor/ Leader
S&F in repairs Switch socket combination 5 in 1, 5 pin 5/15 Amps flush type universal. Make : Havells/Anchor/Leader
S&F in repairs Endura LED Bulk head fitting 20 Watt Make : Philips/ Bajaj/ Wipro/Havells
Taking down and dismantling of ceiling fan, segregation of unserviceable parts, cutting and removing out copper winding, cleaning the armature, rewinding of fan armature with appropriate gauge of super enamelled copper wire with necessary insulating materials such as vertex paper, cotton tape, PVC insulation tape etc varnishing with approved grade of insulation varnish and heating up, re-assembling the fan complete with replacement of unserviceable spares parts, including necessary lathe work for fixing of bush/bearing greasing the same with approved grade of grease, making all electrical connection and supply and fixing the following items and including necessary transportion to workshop, for 1200/1400/1500mm sweep fan all as specified. Note :- Spare parts shall be measured & paid separately :- (i) Split pin - 02 Nos (ii) Connection block - 1 No (iii) Insulation rubber bush. - 01 No
Fixing or hanging only ceiling fan after winding fan under item No. 211 above and connecting up including provision of 3 core 1.5 Sqmm cable from ceiling rose or connector to fan( max up to 1m length) all as specified and directed
All as per item No. 211 here-in-above but exhaust fan of size 225mm to 450mm sweep (except rubber roll, split pin)
All as per item No. 212 here-in-above but exhaust fan of size 225mm to 450mm sweep (except rubber roll, split pin)
Overhauling of ceiling fan of any make and sweep after opening and cleaning rotor bearing and stator properly and oiling/greasing of bearing/ bushes, reassmbling the same, fixing and connecting on its existing position and testing on completion all as specified and as directed including taking down.(Note- (A) Overhauling of ceiling fans will be carried out at AGE E/M Yard only. (B) The spares required shall be measured and paid separately in the relevant items).
Taking down exhaust fan, of any size and type & cleaning/servicing and overhauling the same, refixing the same on its existing position and connection up.
S&F in repairs gun metal bush of any size (Make - MSP).
S&F in repairs bearing for ceiling fan (Make - TATA/SKF No.6201/6202).
S&F in repairs bearing for ceiling fan (Make - TATA/SKF No.6203/6204).
S&F in repairs fan condensor 2.5 MFD (Make – USHA / UNIVERSAL).
S&F in repairs fan condensor 4 MFD (Make – USHA / UNIVERSAL).
S&F in repairs split pin as per existing specification/size.
M&L for Painting of ceiling fan 1200/1400 mm sweep complete including fan blades down rod with one coat of synthetic enamelled paint of white tint on old surface including cleaning and removing dust and dirt and making smooth surface for painting including writing MES No complete all as specified.
S & F in repairs Mild steel work in framed work such as Fan hooks, Clamps, gratings, ladders etc., with ends of bars welded and/ or riveted, or forged and similar work confirming to Fe 410 - O or Fe 310 - O and incl painting to surfaces using two coats of metallic primer and a coat of synthetic enamelled paint of desired colour as directed.
Note :- Schedule of Credit amounting to Rs. 1,86,315.00 to be deducted during AOC
RAINA SALES AND SERVICES
M/S INDIA ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .