Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.3 LAccepted-AOC | L1 | Accepted-AOC L1 Bidder | |
| 2 | L2₹7.3 L+₹1.9 L (35.6%)Rejected-AOC HOUSE NO 97 MOHALLA AFGHANA GALI KRISHAN DWARA JAMMU | JAMMU | JAMMU | JAMMU AND KASHMIR | L2 | Rejected-AOC Other then L1 Bidder | |
| 3 | L3₹7.3 L+₹2.0 L (36.7%)Rejected-AOC C O SECTOR 02 HOUSING COLONY CHANNI HIMMAT JAMMU J K PIN 180015 | JAMMU | JAMMU AND KASHMIR | 180015 | L3 | Rejected-AOC Other then L1 Bidder | |
| 4 | L4₹7.7 L+₹2.4 L (44.3%)Rejected-AOC | L4 | Rejected-AOC Other then L1 Bidder | |
| 5 | L5₹7.7 L+₹2.4 L (44.8%)Rejected-AOC C O OPPOSITE MH MANDA POONCH ROAD AKHNOOR 181201 J K | JAMMU | JAMMU AND KASHMIR | 181201 | L5 | Rejected-AOC Other then L1 Bidder |
Tender Value
₹9.7 L
EMD Value
₹19,500
Closing Date
13 Jul 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE(I)CIF(U) REASI
AGE(I)CIF(U) C/O 56 APO
PROVN OF LT PANEL FOR FRI TRANSFOMER, JCOS ACCN, GS BR AND D AND E COY LINE.
2020_MES_354880_1
AGE(I)CIF(U)-13/2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AOR of AGE(I)CIF(U)
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
AGE(I)CIF(U) REASI
₹19,500
Yes
20 Jul 2020
22 Jun 2020
15 Jul 2020
22 Jun 2020
13 Jul 2020
29 Jun 2020
60 days
Amount
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m deep in soft/loose soil including forming sides and bottom surface to required levels / slops / gradients and getting out complete.
Returning, filling in trenches including spreading leveling, watering well, ramming in layers n.exc 25 cm in soft / loose soil complete.
Removing excavated material to a distance n exc 50 m and depositing at a leve n exc 1.5 m above starting point. complete.
S & L Tubes, `light grade', galvanised, 25mm dia for cable protection with all fittings and fixed complete to walls and ceiling or laid in floors/road crossing including taking up old UNSV GI tubes all as specified.
S & L Tubes, `light grade', galvanised,40 mm dia for cable protection with all fittings and fixed complete to walls and ceiling or laid in floors/road crossing including taking up old UNSV GI tubes all as specified.
S&F MCB distribution board, powder coated, CRCA steel sheet, degree of protection IP 43 - IK 09 with reversible double door, recess mounted, having insulated 100 amp tinned copper bus bar, neutral busbar, earth bar, din bar, detachable gland plate, interconnection, earthing connection, blanking plates in unused spaces as required with ratings TPN, 415 volts, 4 ways. Make - Legrand cat ref no 507670 or equivalent in Schneider or Hager as approved.& ways:-
Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick burried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of the earth plate at a depth not less than 1.5 M below ground level, earth plate surrounded by 15cm thick and packed with layers of charcoal dust and common salt , earth lead of galvanised iron strip of size 25x4 mm connectd to GI earth plate elcectrode by means of bolts, nuts, check nuts and washers of galvanised iron and thimbles and other end of earth wire connected to main switch board and protected by galvanised iron pipe medium grade 15mm bore and 20mm bore light gradeGI pipe with funnel and wire mesh for watering including necessary excavation and earth works. PCC Chamber in cement concrete 1:3:6 type C-2 & RCC cover in M-20 (Design mix ) and all as shown in Electrical Plate No. 3 of SSR ( Part-I) of 2009 and testing on completion. (Note : Earth result should not exceed 2 Ohms)
Supply, laying and testing cable XLPE insulated screened PVC bedded, galvanised steel strips or wire armoured, electric power cable (heavy duty) with stranded aluminium conductor, 1100 volts grade of size 10 sqmm 2 core.
Supply, laying and testing cable XLPE insulated screened PVC bedded, galvanised steel strips or wire armoured, electric power cable (heavy duty) with stranded aluminium conductor, 1100 volts grade of size 16 sqmm 4 core.
Supply, laying and testing cable XLPE insulated screened PVC bedded, galvanised steel strips or wire armoured, electric power cable (heavy duty) with stranded aluminium conductor, 1100 volts grade of size 25 sqmm 4 core.
Supply, laying and testing cable XLPE insulated screened PVC bedded, galvanised steel strips or wire armoured, electric power cable (heavy duty) with stranded aluminium conductor, 1100 volts grade of size 35 sqmm 3.5 core.
Supply, laying and testing cable XLPE insulated screened PVC bedded, galvanised steel strips or wire armoured, electric power cable (heavy duty) with stranded aluminium conductor, 1100 volts grade of size 50 sqmm 3.5 core.
Supply, laying and testing cable XLPE insulated screened PVC bedded, galvanised steel strips or wire armoured, electric power cable (heavy duty) with stranded aluminium conductor, 1100 volts grade of size 70 sqmm 3.5 core.
Supply, laying and testing cable XLPE insulated screened PVC bedded, galvanised steel strips or wire armoured, electric power cable (heavy duty) with stranded aluminium conductor, 1100 volts grade of size 95 sqmm 3.5 core.
Supplying, installation, testing & commissioning in CPRI approved outdoor cubical type LT of size 1.5Mx1.2Mx0.60M depth,(HxBxD) panel suitable for 415V, 3 phase, 4 wire 50 Hz, AC supply system with short circuit withstand capacity 35 MVA for 1 second, IP 54 protection, fabricated in compartmentalized design with CRCA sheet 3.15 mm thick, factory made, totally enclosed having front and rear openable, powder coated, dust, weather & vermin proof, having TPN aluminium bus bars of rating 1.5 times that of controlling MCCB supported on 'F' class SMC insulators, bottom base channel of MS section not less than 75 mm x 40 mm x 5 mm thick, entire panel shall have a common aluminium earth bar of size 25 mm x 5 mm at the rear with 2 Nos earth stud, solid connections from main bus bar to switchgears with required size bus bars and control wiring with minimum 1.5 sqmm PVC insulated copper conductor cable, cable alleys, cable gland plates including digital multi functional meter to measure voltage, current, PF & frequency and mounted on by making suitable PCC foundation, necessary inter connection including following controls :- Incoming:- One number MCCB 125 amp, 4 pole, Ics 25 KA, 415 volts, 50 Hz with thermal magnetic release adjustable between 40% to 100% against overload setting as per Legrand cat ref no. 4200 56 or equivalent in Schneider or Hager as approved. Outgoing:- (i) Three numbers MCCB 63 amp, 4 pole, Ics 25 KA, 415 volts, 50 Hz, thermally adjustable between 70% to 100% against overload setting as per Legrand cat ref no. 420053 or equivalent in Schneider or Hager as approved.
Supplying, installation, testing & commissioning in CPRI approved outdoor cubical type LT of size 1.2x1.0Mx0.60M depth,(HxBxD) panel suitable for 415V, 3 phase, 4 wire 50 Hz, AC supply system with short circuit withstand capacity 35 MVA for 1 second, IP 54 protection, fabricated in compartmentalized design with CRCA sheet 3.15 mm thick, factory made, totally enclosed having front and rear openable, powder coated, dust, weather & vermin proof, having TPN aluminium bus bars of rating 1.5 times that of controlling MCCB supported on 'F' class SMC insulators, bottom base channel of MS section not less than 75 mm x 40 mm x 5 mm thick, entire panel shall have a common aluminium earth bar of size 25 mm x 5 mm at the rear with 2 Nos earth stud, solid connections from main bus bar to switchgears with required size bus bars and control wiring with minimum 1.5 sqmm PVC insulated copper conductor cable, cable alleys, cable gland plates including digital multi functional meter to measure voltage, current, PF & frequency and mounted on by making suitable PCC foundation, necessary inter connection including following controls :- Incoming:- One number MCCB 63 amp, 4 pole, Ics 25 KA, 415 volts, 50 Hz with thermal magnetic release adjustable between 40% to 100% against overload setting as per Legrand cat ref no. 420053 or equivalent in Schneider or Hager as approved. Outgoing:- (i) Four numbers MCCB 40 amp, 4 pole, Ics 16 KA, 415 volts, 50 Hz, thermally adjustable between 70% to 100% against overload setting as per Legrand cat ref no. 420012 or equivalent in Schneider or Hager as approved.
Supplying, installation, testing & commissioning in CPRI approved outdoor cubical type LT panel of size 1.5Mx1.2Mx0.60M depth,(HxBxD) suitable for 415V, 3 phase, 4 wire 50 Hz, AC supply system with short circuit withstand capacity 35 MVA for 1 second, IP 54 protection, fabricated in compartmentalized design with CRCA sheet 3.15 mm thick, factory made, totally enclosed having front and rear openable, powder coated, dust, weather & vermin proof, having TPN aluminium bus bars of rating 1.5 times that of controlling MCCB supported on 'F' class SMC insulators, bottom base channel of MS section not less than 75 mm x 40 mm x 5 mm thick, entire panel shall have a common aluminium earth bar of size 25 mm x 5 mm at the rear with 2 Nos earth stud, solid connections from main bus bar to switchgears with required size bus bars and control wiring with minimum 1.5 sqmm PVC insulated copper conductor cable, cable alleys, cable gland plates including digital multi functional meter to measure voltage, current, PF & frequency and mounted on by making suitable PCC foundation, necessary inter connection including following controls :- Incoming:- One number MCCB 200 amp, 4 pole, Ics 35 KA, 415 volts, 50 Hz with thermal magnetic release adjustable between 40% to 100% against overload setting as per Legrand cat ref no. 420248 or equivalent in Schneider or Hager as approved.Outgoing:- (i) Four numbers MCCB 63 amp, 4 pole, Ics 25 KA, 415 volts, 50 Hz, thermally adjustable between 70% to 100% against overload setting as per Legrand cat ref no. 420053 or equivalent in Schneider or Hager as approved.
Design,Supply, installation, testing and commissioning of bus bar chember box of size 0.5Mx0.8Mx0.60M depth,(HxBxD) outdoor type factory fabricated made out of CRCA sheet of 3.15 mm thick ,fully enclosed and angle iron frame of size 40 x 40 x 6mm thick and T section with front and rear openable double door shutter, dust and vermin proof and rear opening complete with locking arrangement, having a system of bus bars of aluminium of suitable size of 100 Amps duly insulated and mounted on Epoxy/porcelain insulators in totally enclosed chamber with three phase and neutral 415 volts, AC, system. provn of suitable cable glands, duly powder coated.
S&F MCBs as per load requirement 'C' series of breaking capacity 10 KA, ISI marked including required wiring connections with copper lugs of suitable size provided in MCB DBs of Single pole 6 to 16 amp.
S&F MCBs as per load requirement 'C' series of breaking capacity 10 KA, ISI marked including required wiring connections with copper lugs of suitable size provided in MCB DBs of Four pole 40 to 63 amp.
M&L for clean unwashed dry fine river sand for filling in trenches for cable protection 8 cm below cable and 15 cm above cable and bringing it 10 cm by gently punning complete. Note : Only punned thickness 18 cm shall be taken for payment purpose.
Supplying and laying old size bricks, common burnt clay building bricks sub class 'B' designation 75 complete.
M/S RAVI KUMAR
MAMTA ENTERPRISES
CHOPRA CONSTRUCTIONS
Usha Engineering Co.
Jiwan Singh
ROYAL ENGINEERS AND CONTRACTORS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .