Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹1.5 LAccepted-Finance H NO 732 BURARI VILLAGE DELHI 110084 | NORTH | DELHI | 110084 | ₹1.5 L | 1 | Accepted-Finance 1 |
| 2 | 2₹1.5 LRejected-Finance | ₹1.5 L | 2 | Rejected-Finance 2 |
| 3 | 3₹1.5 LRejected-Finance B 17 2 GALI NO 20 JITAR NAGAR NEAR PARVANA ROAD KRISHNA NAGAR EST DELHI 51 | NEW DELHI | DELHI | 110001 | ₹1.5 L | 3 | Rejected-Finance 3 |
| 4 | 4₹1.6 LRejected-Finance | ₹1.6 L | 4 | Rejected-Finance 4 |
Tender Value
₹1.6 L
EMD Value
₹3,100
Closing Date
25 Mar 2026, 3:00 pmClosed
EEE/KPZ
EEE/KPZ
Enlistment copy of MCD,CPWD, State PWDs, Urban Local Bodies and other Government departments
2026_MCD_271880_1
TC/ENGG./EEE/KPZ/2025-26/58.1
Open Tender
Electrical Works
30 days
EEE/KPZ
Please refer Tender documents.
3 documents required · 3 mandatory
₹590
₹3,100
25 Mar 2026
18 Mar 2026
25 Mar 2026
18 Mar 2026
25 Mar 2026
18 Mar 2026
Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sqmm FRLS/HFFR PVC insulated copper conductor single core cable 1.5 sqmm FRLS/HFFR PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/ PVC conduit including dismantling as required.Group B
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.(a) 3x2.5 sq mm
(b)6x2.5 sq mm
© 3x4 sq mm
(d)6x4 sq mm
Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2x6 sq. mm + 1x6 sq. mm earth wire
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of receesed conduit as required.(a) 25 mm
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc.as required. 5/6 A switch
3 pin 5/6 A socket outlet
Supplying ad fixing suitable size GI box with modular plate and cover in front on surface or in recess , including Providing and fixing 6 pin 5/6 &15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required
Supplying and fixing following size/ modules, GI box along with modular base and cover plate for modular switches in recess etc. as required. 3 Module (100mmX75mm)
6 Module (200mmX75mm)
12 Module (200mmX150mm)
Supplying and fixing PVC batten/angle holder including connections etc.as required.
Supplying and fixing following way,single pole and neutral, sheet steel, MCB distribution board, 240 V , on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 16 way, Double door
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc.as required. Single pole
Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 amp
Supplying and fixing suitable size GI Box with modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25A modular SP MCB, "C" curve including connections, painting etc. as required.
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt ) as required.
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
Brush Less Direct Current (BLDC) Motor Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal ( Aluminum alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, remote suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Ceiling Fan compliant to IS 374:2019 fan i/c external connectionswith 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. complete as req 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum)
Supplying, installation, Testing & Commissioning of 18-22 watt LED surface mounted Batten light of CRCA Sheet Body (Thickness ≥ 0.50 mm) material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85% ,Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range 15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80 , Flicker free (flicker should be below 5 %), life time (LED,Driver & electrical circuitry), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6000°K/ 6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >120<135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineerin-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminum Body (Thickness ≥ 1
Supplying and fixing modular blanking on the existing modular plate & switch box excluding modular plate as reqd.
Supply of 9 Watt LED Retrofit lamp suitable for B22 holder
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.45 MB
Tender_Condition11.pdf
Tender Documents • 0.44 MB
MCD_GCC_Circulars_2025.pdf
Tender Documents • 12.97 MB
BOQ_317127.xls
BOQ • 0.31 MB
Download all tender documents and submit your bid