| 1.00 | Numerical Protection Relay for LT Incomer feeder, Outgoing Feeder and Bus coupler with Auxiliary supply 48-240V AC/DC, Incomer Range 800-4000 Amp, communication on IEC 61850.
Following Protection required:-
1.Under Voltage, 2.Over Voltage, 3.Short circuit, 4.Overcurrent, 5.Earth fault, 6.Restricted Earth F, 7.Circuit Breaker Failure.
Other feature required: -
1. Relay self monitoring & diagnostics.
2. Trip Circuit supervision.
3. Event log, Fault History with date & time at least previous 10 fault.
4.Check synch.
5.16 B Input/8 B Output
6.all function and display of Human machine Interface (HMI) shall be remotely accessible.
7.Access to protection setting mode shall be protected by a password that can be personalized by the user.
8.The device shall support a webserver/web HMI.
9.The device shall support virtual simulation through which protection functions and logic testing can be achieved without any separate software or secondary injection kit.
10. Nos. of Voltage I/P required=04
11. Nos. of Current I/P required=04
Make:-ABB/Larsen & Toubro/General Electric/Siemens/Schneider Electric. | 16 | EA | 1,91,341.72 ₹30,61,467.52 Lowest | 1,92,564.2 ₹30,81,027.2 |
| 3.00 | Installation, Testing and Commissioning of Numerical feeder Protection Relay. | 16 | JOB | 73,030.2 ₹11,68,483.2 | 69,112.6 ₹11,05,801.6 Lowest |
Tender Value
Refer Docs
EMD Value
₹40,000
Closing Date
27 Sept 2025, 9:00 amClosed
SE, MMC, PTPP, PARICHHA
O/o SE, MMC, PTPP, PARICHHA
Supply, Installation, Commissioning and Testing of Numerical Feeder Protection Relay (Make- ABB,L and T ,General Electric/ Siemens/Schneider Electric) in Unit No. 5 and 6 2x250MWParichha
2025_RVUNL_1069856_2
N-PAR/B/MMC1/PD01/6000009105
Open Tender
Electrical Work/ Equipment
Fixed-rate
180 days
PTPP, PARICHHA
as per tsd
3 documents required · 3 mandatory
₹1,180
DY CAO CFA BO PTPP PARICHHA
₹40,000
12 Mar 2026
16 Sept 2025
29 Sept 2025
16 Sept 2025
27 Sept 2025
16 Sept 2025
16 Sept 2025 - 27 Sept 2025
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].