Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹78.8 LAccepted-AOC 205 PARSHAV VIHAR PLOT NO 50 IP EXTN PARPARGANJ DELHI 110092 | EAST | DELHI | 110092 | L1 | Accepted-AOC QUOTED AMOUNT IS RASONABLE | |
| 2 | L2₹82.2 L+₹3.3 L (4.25%)Rejected-Finance 10 SUBASH COLONY DEF LAB ROAD RATANADA JODHPUR 342006 RAJ | JODHPUR | JODHPUR | RAJASTHAN | 342006 | L2 | Rejected-Finance OTHER THAN LOWEST | |
| 3 | L3₹82.6 L+₹3.7 L (4.70%)Rejected-Finance A 47D RAM DUTT ENCLAVE UTTAM NAGAR NEW DELHI 110059 | WEST | DELHI | 110059 | L3 | Rejected-Finance OTHER THAN LOWEST | |
| 4 | Rejected-Technical 1 225 5 6 SADAR BAZAR DELHI CANTT 110010 | NEW DELHI | DELHI | 110010 | - | Rejected-Technical MOU NOT GIVEN |
| Sl No | Description | Qty | Unit | Saini Enterprises L1 | Akhil Enterprises L3 | PANWAR ELECTRICALS L2 |
|---|---|---|---|---|---|---|
| 1.00 | Comprehensive/ Routine maintenance of VRF/VRV type Acs for following size and capacity VRF/VRV (Make:- Carrier, Blue Star) (A) OUT DOOR UNIT 22 HP:- Air cooled VRF/VRV system - 22 Nos (I) IN DOOR UNIT CASETTE TYPE :- 1 TR - 01 No, 1.5 TR - 01 No, 2.0 TR - 25 Nos, 2.5 TR - 01 No, 3.0 TR - 01 No, 3.5 TR - 02 Nos, (ii) IN DOOR UNIT CEILING MOUNTED DUCTABLE TYPE:- 8.0 TR - 30 Nos. (iii) IN DOOR UNIT (Air Handling Unit) :- Capacity (3500 CFM - 01 No) | 11 | Per Month | 2,31,500 ₹25,46,500 Lowest | 2,35,000 ₹25,85,000 | 2,40,000 ₹26,40,000 |
| 2.00 | Comprehensive/ Routine maintenance of VRF/VRV type Acs for following size and capacity VRF/VRV. (Make :- Blue Star) (A) OUT DOOR UNIT 28 HP:- Air cooled VRF/VRV system - 1 Nos (I) IN DOOR UNIT (HIGH WALL UNIT) :- 1.3 TR - 01 No, 2 TR - 05 No, 2.6 TR - 6 Nos, | 11 | Per Month | 13,400 ₹1,47,400 | 13,000 ₹1,43,000 Lowest | 15,000 ₹1,65,000 |
| 3.00 | Comprehensive/ Routine maintenance of VRF/VRV type Acs for following size and capacity VRF/VRV. (Make :- Blue Star) (A) OUT DOOR UNIT 26 HP:- Air cooled VRF/VRV system - 02 Nos (I) IN DOOR UNIT (HIGH WALL UNIT) :- 1.3 TR - 01 No, 2 TR - 05 No, 2.6 TR - 6 Nos, | 11 | Per Month | 24,900 ₹2,73,900 | 24,000 ₹2,64,000 Lowest | 28,000 ₹3,08,000 |
| 4.00 | Comprehensive/ Routine maintenance of VRF/VRV type Acs for following size and capacity VRF/VRV. (Make:- Blue Star, Daikin) (A) OUT DOOR UNIT 12 HP:- Air cooled VRF/VRV system - 07 Nos (I) IN DOOR UNIT (Air Handling Unit) :- Capacity (3200 CFM - 02 No) (B) OUT DOOR UNIT 16 HP:- Air cooled VRF/VRV system - 01 Nos (I) IN DOOR UNIT (Air Handling Unit) : Capacity (4000 CFM - 01 No) | 11 | Per Month | 47,800 ₹5,25,800 | 47,500 ₹5,22,500 | 40,000 ₹4,40,000 Lowest |
| 5.00 | Comprehensive/ Routine maintenance of VRF/VRV type Acs for following size and capacity VRF/VRV. (Make:- LG) (A) OUT DOOR UNIT 20 HP:- Air cooled VRF/VRV system - 02 Nos (B) OUT DOOR UNIT 14 HP:- Air cooled VRF/VRV system - 01 Nos (I) IN DOOR UNIT (4 way and 2 way Cassette ) :- 1.2 TR- 12 Nos, 1.75 TR- 8 Nos, 2.0 TR - 8 Nas | 11 | Per Month | 25,800 ₹2,83,800 | 25,000 ₹2,75,000 Lowest | 28,000 ₹3,08,000 |
| 5.01Note:- (i) Four preventive Maintenance calls shall be provided during the contract period of one year. They shall be as per dates and time provided by customer during normal working hours (Monday to saturday between 9:00 AM to 7:00 PM) on any working day. Washing the condenser coil with water to remove the dust accumulated inside the coil. Cheking the refrigerant pipe joint with solution for any leakage in the system and ensuring that the entire piping is made fully functional. Checking & Tightening all bolts & nuts. Cheking & making fully functional all electric connections of control panel. Cheking & making fully functional all electric connections of compressor & condenser fan motors. Cheking the suction/ discharge pressure of compressor to study any abnormal running condition & rectifying the same if noticed. Checking voltage & current to study / detect any abnormal running conditions and assist in rectifying the same if noticed with in our set free unit. BLUE STAR, on its own, would carry out rectification steps in the equipment if needed, otherwise advice customer to take corrective action at their end. Checking voltage imbalance between phases and pointing out any problem to customer for corrections, provided any correction required in the equipment would be corrected out by BLUE STAR/Carrier/Daikin/LG. Cheking of unloading solenoid valves and ensuring smooth functioning of the same. | ||||||
| 5.02(ii) The quoated rate include comprehensive maintenace, Repaire and replacement including attending All major brekdown like compressor failure, replacement of electrical control panels and PCBs, Remote control etc. The quoated rate include the periodical washing of filters as per OEM recommendations . Reparing and replacement of expansion valve, safty devices and valves , replacement / rewinding of motors and pumps , electrical contactor and relays, repaire and replacement of filters etc , and other routine items such as refrigent gas, compressure oil and grase, Lugs, Gland, Wires and cables etc required for smooth operation of plant shall be provide by contractor at his own cost as per the manufacturer's instructions shall be deemed icluluded in the unit rates quoted by the contractor. | ||||||
| 5.03(iii) The cost of spares and labour for any minor or major repairs as and when required (as recommended by the OEM during inspection/analysis report) shall be provided by the contractor at no extra cost and rate for the same are deemed to be included in the unit rates of item as above. (iv) Cost of refrigerant gas and compressor oil will be included in quoted rate. (v) The contractor is liable to maintain 21 degree centigrade temperature (plus/minus 2 degree C) and 50 % relative humidity (plus/minus 5%) in the rooms. (vi) Contractor is required to enter in to "Level-3" MOU with M/S Blue-Star Company/Carrier/ Daikin/LG. The contractor shall upload/ submit scanned copy of MOU with M/S Blue-Star /Carrier/Daikin/LG alongwith his application in Cover No 01 and also submit hard copy of MOU with his application before the last date for bid submission failing which Cover 2 shall not be opened and No claim what so ever on this account shall be entertained. The service Engineer from M/S Blue-Star/Carrier/Daikin/LG (original OEM) will visit the A/C plant minimum one time in a month and will submit inspection report to the Engineer-in-charge. Necessary repair action will be taken immideately if/as required and periodical maintenance of plant will be carried out by contactor as per tecknical instructions OEM . | ||||||
| 5.04vii) In case of any minor fault in the machineries of Central AC plant due to which the plant is put off more than 12 hours the following penalties shall be recovered from the contractor :- (viii) Rs. 10000/- per day will be recovered from the contractor for non rectification of defect/replacement of any unserviceable spares after 12 hours from lodging of complaint telephonically or verbaly. (ix) Thereafter Rs. 10000/- will be added every day till rectification of fault/replacement of unserviceable spares as directed. | ||||||
| 5.05(x) In case of any minor fault in the machineries of Central AC plant due to which the plant is put off more than 12 hours the following penalties shall be recovered from the contractor :- (xi) Rs. 10000/- per day will be recovered from the contractor for non rectification of defect/replacement of any unserviceable spares after 12 hours from lodging of complaint telephonically or verbaly. (xii) Thereafter Rs. 10000/- will be added every day till rectification of fault/replacement of unserviceable spares as directed. Note :- Any Old U/S material taken From Item Ser No 1 to 5 contactor will be handover to department will be material taken on salvage ledger. | ||||||
Tender Value
₹95 L
EMD Value
₹1.7 L
Closing Date
17 Jul 2025, 9:00 amClosed
CWE DELHI CANTT
HQ CWE DELHI CANTT 110010
REPAIR AND REPLACEMENT OF UNSV SPARES OF PACKAGE TYPE AC PLANT COMPREHENSIVE MAINT OF VRF AC PLANT AT NEW OPD COMPLEX AND CONNECTED MISC E AND M WORK AT BHDC UNDER GE EAST DELHI CANTT 10
2025_MES_703908_2
CWE/D-83/2024-25
Open Tender
Civil Works
Item Rate
330 days
DELHI CANTT
Please refer Tender documents
8 documents required · 8 mandatory
₹1,000
GE EAST DELHI CANTT
₹1.7 L
3 Nov 2025
19 Jun 2025
18 Jul 2025
19 Jun 2025
17 Jul 2025
3 Jul 2025
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .