Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.6 LAccepted-AOC 114 SHASTRI NAGAR MEERUT | MEERUT | UTTAR PRADESH | 245206 | L1 | Accepted-AOC L1 and Reasonable | |
| 2 | L2₹29.1 L+₹1.1 L (4.08%)Rejected-Finance | L2 | Rejected-Finance In order but L2 | |
| 3 | L3₹33.8 L+₹5.9 L (21.2%)Rejected-Finance 289 KASERU KHERA MAWANA ROAD MEERUT 250001 U P | MEERUT | UTTAR PRADESH | 250001 | L3 | Rejected-Finance In order but L3 |
Tender Value
Refer Docs
EMD Value
₹64,560
Closing Date
12 Mar 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE(U)E/M Meerut
Roorkee road Meerut cantt
SPECIAL REPAIR OF ELECTRIC SUPPLY SYSTEM AT BELVEDERE COMPLEX, CDA(ARMY) MEERUT UNDER GE(U) E/M MEERUT CANTT
2021_MES_498207_2
8403/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Meerut
Please refer Tender documents.
10 documents required · 10 mandatory
₹500
GE(U)E/M Meerut
₹64,560
Yes
30 Apr 2022
19 Feb 2022
14 Mar 2022
19 Feb 2022
12 Mar 2022
26 Feb 2022
90 days
Amount
Dismantling and taking down LT UG cable of any size and type complet all as specified and directed. Note- Excavation and earthwork shall be measure and paid separately under relevant item.
Excavating in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundations etc. or for shafts, well cess pits, manholes,pier holes, laying of pipe and cables etc. but not exceeding 10 sqm on plan including dressing/trimming sides and levelling/grading & ramming bottom of excavation and getting out in soft/loose soil complete all as specified.
Returning ,filling in , including spreading , levelling , watering and well ramming in layer not exceeding 25 cm thick in soft/loose soil complete all as specified.
Removing excavated material ( soils) not exceeding 50m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified.
Dismantling and taking down existing unserviceable GI pipe and Supplying and fixing 40mm nominal bore Galvanised mild steel pipe /tubing, light grade for protection of earth lead / passing cable complete with all fittings, laid in trenches / under roads, drain, paths, fixed to poles/ walls with Mild steel clamps , bolts , nuts and washers complete all as specified of the following bore (Excavation & Earth work , Mild steel clamps, bolts , nuts and washers shall be measured and paid separately)
Dismantling and taking down existing unserviceable GI pipe and Supplying and fixing 80mm nominal bore Galvanised mild steel pipe /tubing, light grade for protection of earth lead / passing cable complete with all fittings, laid in trenches / under roads, drain, paths, fixed to poles/ walls with Mild steel clamps , bolts , nuts and washers complete all as specified of the following bore (Excavation & Earth work , Mild steel clamps, bolts , nuts and washers shall be measured and paid separately)
M&L fly ash old size bricks, straight or curved on plan , laid flat with width equal to length of brick , laid dry over electric cable for protection all as specified.
Material and labour for river sand, unwashed and screened dry ) for cushioning to under ground cable in trenches below and around under ground cable including spreading and levelling complete as specified and directed . (Note:Punned thickness shall be measured for the purpose of payment)
Supplying, laying or fixing, jointing and testing LT under ground electric power cable Crossed linked polyethylene ( XLPE Cable) insulated, galvanised steel strip or wire armoured, ISI-7098 Marked, with aluminium conductor multi stranded , heavy duty 1100 Volts grade of 300 sqmm 3 1/2 core ,complete all as specified laid in trenches/ laid under floor or fixed naked with walls / on poles/ in ducts /in GI pipes etc.( Excavation, earth work, sand cushioning, protection bricks/ tiles/ block,Clamps, nuts , bolts, washers and pipe shall be measured and paid separately under appropriate items ).
Supplying, laying or fixing, jointing and testing LT under ground electric power cable Crossed linked polyethylene ( XLPE Cable) insulated, galvanised steel strip or wire armoured, ISI-7098 Marked, with aluminium conductor multi stranded , heavy duty 1100 Volts grade of 240 sqmm 3 1/2 core ,complete all as specified laid in trenches/ laid under floor or fixed naked with walls / on poles/ in ducts /in GI pipes etc.( Excavation, earth work, sand cushioning, protection bricks/ tiles/ block,Clamps, nuts , bolts, washers and pipe shall be measured and paid separately under appropriate items ).
Supplying, laying or fixing, jointing and testing LT under ground electric power cable Crossed linked polyethylene ( XLPE Cable) insulated, galvanised steel strip or wire armoured, ISI-7098 Marked, with aluminium conductor multi stranded , heavy duty 1100 Volts grade of 185 sqmm 3 1/2 core ,complete all as specified laid in trenches/ laid under floor or fixed naked with walls / on poles/ in ducts /in GI pipes etc.( Excavation, earth work, sand cushioning, protection bricks/ tiles/ block,Clamps, nuts , bolts, washers and pipe shall be measured and paid separately under appropriate items ).
Supplying, laying or fixing, jointing and testing LT under ground electric power cable Crossed linked polyethylene ( XLPE Cable) insulated, galvanised steel strip or wire armoured, ISI-7098 Marked, with aluminium conductor multi stranded , heavy duty 1100 Volts grade of 120 sqmm 3 1/2 core ,complete all as specified laid in trenches/ laid under floor or fixed naked with walls / on poles/ in ducts /in GI pipes etc.( Excavation, earth work, sand cushioning, protection bricks/ tiles/ block,Clamps, nuts , bolts, washers and pipe shall be measured and paid separately under appropriate items ).
Supplying, laying or fixing, jointing and testing LT under ground electric power cable Crossed linked polyethylene ( XLPE Cable) insulated, galvanised steel strip or wire armoured, ISI-7098 Marked, with aluminium conductor multi stranded , heavy duty 1100 Volts grade of 95 sqmm 3 1/2 core ,complete all as specified laid in trenches/ laid under floor or fixed naked with walls / on poles/ in ducts /in GI pipes etc.( Excavation, earth work, sand cushioning, protection bricks/ tiles/ block,Clamps, nuts , bolts, washers and pipe shall be measured and paid separately under appropriate items ).
Supplying, laying or fixing, jointing and testing LT under ground electric power cable Crossed linked polyethylene ( XLPE Cable) insulated, galvanised steel strip or wire armoured, ISI-7098 Marked, with aluminium conductor multi stranded , heavy duty 1100 Volts grade of 70 sqmm 3 1/2 core ,complete all as specified laid in trenches/ laid under floor or fixed naked with walls / on poles/ in ducts /in GI pipes etc.( Excavation, earth work, sand cushioning, protection bricks/ tiles/ block,Clamps, nuts , bolts, washers and pipe shall be measured and paid separately under appropriate items ).
Supplying, laying or fixing, jointing and testing LT under ground electric power cable Crossed linked polyethylene ( XLPE Cable) insulated, galvanised steel strip or wire armoured, ISI-7098 Marked, with aluminium conductor multi stranded , heavy duty 1100 Volts grade of 50 sqmm 3 1/2 core ,complete all as specified laid in trenches/ laid under floor or fixed naked with walls / on poles/ in ducts /in pipes etc.( Excavation, earth work, sand cushioning, protection bricks/ tiles/ block,Clamps, nuts , bolts, washers and pipe shall be measured and paid separately under appropriate items ).
Supplying, laying or fixing, jointing and testing LT under ground electric power cable Crossed linked polyethylene ( XLPE Cable) insulated, galvanised steel strip or wire armoured, ISI-7098 Marked, with aluminium conductor multi stranded , heavy duty 1100 Volts grade of 16 sqmm 4 core ,complete all as specified laid in trenches/ laid under floor or fixed naked with walls / on poles/ in ducts /in GI pipes etc.( Excavation, earth work, sand cushioning, protection bricks/ tiles/ block,Clamps, nuts , bolts, washers and pipe shall be measured and paid separately under appropriate items ).
Supplying, transporting, erecting and fixing Steel tubular swaged poles type 410 SP-31 ( 9.0 metres long) complete with cast iron / Mild steel base plate, CI finial, taper plug, bolts, nuts and screws as specified, including necessary excavation and earth work in soft/ loose soil , PCC 1:3:6 type C2 in foundation and around poles and PCC 1:2:4 type B1 as in plinth block duly finished even and smooth without using extra cement, disposal of surplus soil to a distance not exceeding 50 m and depositing where directed, painting exposed surafces steel tubular poles with two coats of aluminium paint over one coat of red oxide primer and and black bituminous paint on steel surafces embedded in concrete and providing 300 mm wide bands (5 bands/ straps with fluorescent synthetic enamel paint in alternate colour of black and white from plinth block and numbering of poles , painting embedded portion of poles with one coat of bituminous paint complete all as specified and shown in drg No.TD/EM/1and directed.
S&F pole mounting type junction box factory made of size 350x250x150mm of CRCA sheet duly powder coated with front openable hinged door , locking arrangements, with 4 Nos aluminium bus bars 40 Amps rating mounted on porcelain insulator, cable glands and lugs consisting DIN type rails for fixing MCB SP 6/10 Amps, 10 kA, suitable for domestic loading -01 no. including mild steel flat iron clamp made out of 40x4mm FI, nuts, bolts and washers duly painted with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified.(MCB shall not be measured and paid separately and shall deemed included in the unit rate)
S&F in repairs 3 core , stranded copper conductor cable 2.5 sqmm, PVC insulated and PVC sheathed , 1100 Volts grade for making connections to street light fittings complete all as specified and directed.
Taking down existing unserviceable LED light fittings with brackets and S&F Energy saving & environment freindly Light Emitting Diode (LED) street light fitting made out of pressure die cast anodised aluminium with toughened glass cover housing 48 Watt to achieve B1 class road illumination as per IS: 1944 and as per national lighting code using each LED >1 watt and <3 watt , LED chip efficiency >= 135 Lumens/Watt, CRI>70, CCT 5000K to 6500K with LED life span at 70% of light output 50000 hours with suitable driver 140V to 270V universal type, with bult in surge protection >5KV, 50 Hz +/- 3% , pf 0.95, THD <10% with system efficiency >85 lumens/ Watt and power efficiency >=90% and overall IP 65 or better , driver and luminaire shall comply LM-80/IS:16105 and with and including street light bracket made out of 25mm dia or higher GI pipe light grade, 1.50metre long bend to shape 120 degree angle with suitable adaptor fixed to pole / wall/ ceiling by two Nos MS clamp made out of flat iron size 40x6mm with nuts, bolts and washers complete all as specified and directed by EIC.
S&F LED floodlight fitting for high mast application, 180/200 watt , IP 65complete all as specified and directed.
M&L for auguring of hole suitable for passing 40mm to 100mm bore pipe in true horizontal position under road, PCC paths etc., by means of mechanical ring/ auger after doing ultrasound to prevent any damage to existing cables pipe line specified and directed coming in the route not exceeding 1.5 m in depth below existing surface level of road and not excd 30M in length complete all as specified. Note: Pipe shall be measured and paid separately under appropriate items and any dahage to existing cables of anytype shall be made good by the Bidder without any extra cost to department.
Supplying, installing, commissioing and testing of factory made ,CPRI approved ,LT switchgear panel board of size 1200mmx1000mmx500mm (min) , IP-54 (outdoor type) , 415 Volts, 50 Hz, AC supply, three phase and neutral ( 4 wire) , 1000 Amps aluminium bus bars 4 pole , duly insulated with heat shrinkable sleeves as per colour code supported on epoxy insulators , having independent compartment for insulated bus bar, incoming feeder and each out going feeder i.e cubical type, made out of 3.15mm thick CRCA sheet , rigid mild steel angle iron frame of 50mmx50mmx6mm with 600mm long extended legs grouting in PCC 1:3:6 type C2 block of size 300mmX200mmx300mm, duly epoxy powder coated internally and externally with approved shade, rubber gasketted, hinged front and back openable doors with proper locking arrangements for dust and vermin proof ,complete including suitable size cable alley, lugs , cable glands,common earth bus bar of GI strip 32x6mm at bottom and making connections with MCCB spreaders,/ wiring with suitable size SC PVC insulated copper conductor cable, locking arrangements 65mm size and lock with keys, earthwork and excavation comprising of the followings and specified hereafter:-
Incoming:-
FP, MCCB, Adjustable magnetic release setting Ics= 100% Icu, 50 KA, 500 Amps, 415V , -01 No.(incoming)
Aluminium busbars suitable for 1000 Amps, 3 Phase, 4 wire system, fixed on insulators -01 Set
LED type indication lamps ( R-Y-B) with holder panel mounting type complete all as specified. -01 No.
Outgoing:-
FP, MCCB, Adjustable thermal magnetic release setting Ics= 100% Icu, 36 KA, 250 Amps, 415V , -04 Nos.
FP, MCCB, Adjustable thermal 70%-100% and fixed magnetic setting Ics= 100% Icu, 25 KA, 160 Amps, 415V , -02 Nos.
Supplying, installing, commissioing and testing of factory made ,CPRI approved ,LT switchgear panel board of size 1000mmx800mmx400mm (min) , IP-54 (outdoor type) , 415 Volts, 50 Hz, AC supply, three phase and neutral ( 4 wire) , 800 Amps aluminium bus bars 4 pole , duly insulated with heat shrinkable sleeves as per colour code supported on epoxy insulators , having independent compartment for insulated bus bar, incoming feeder and each out going feeder i.e cubical type, made out of 3.15mm thick CRCA sheet , rigid mild steel angle iron frame of 50mmx50mmx6mm with 600mm long extended legs grouting in PCC 1:3:6 type C2 block of size 300mmX200mmx300mm, duly epoxy powder coated internally and externally with approved shade, rubber gasketted, hinged front and back openable doors with proper locking arrangements for dust and vermin proof ,complete including suitable size cable alley, lugs , cable glands,common earth bus bar of GI strip 32x6mm at bottom and making connections with MCCB spreaders,/ wiring with suitable size SC PVC insulated copper conductor cable, locking arrangements 65mm size and lock with keys, earthwork and excavation comprising of the followings and specified hereafter:-
Incoming:-
FP, MCCB, Adjustable thermal magnetic release setting Ics= 100% Icu, 36 KA, 400 Amps, 415V , -01 No.(incoming)
Aluminium busbars suitable for 800 Amps, 3 Phase, 4 wire system, 01 Set
LED type indication lamps ( R-Y-B) with holder panel mounting type complete all as specified. -01 No.
Outgoing:-
FP, MCCB, Adjustable thermal magnetic release setting Ics= 100% Icu, 35 KA, 250 Amps, 415V , -02 Nos.
FP, MCCB, Adjustable magnetic release setting Ics= 100% Icu, 25 KA, 160 Amps, 415V , -02 Nos.
Supplying and fixing automatic operation street light timing switch having lighting control (ON-OFF) through Astronomical Calculation of Sun rise/ sun set by setting date, time and degree of longitude and latitude without separate light sensors and prewired with suitable size of copper conductor single core PVC insulated and sheathed cable and all mechanism fitted into panel, outdoor type , pole mounted with FI 25x4mm clamps , nuts, bolts and washers dully painted, connecting and testing factory made , epoxy powder coated, Three Phase street light panel, digital 24 hrs, suitable for 5KW (max) complete with under and over volt protection relay, 65/63AmpsTFP Contactor, and 63 Amps SPN MCBs , 250Volt and fixed on pole/ wall/ feeder pillar complete all as specified and directed.
M&L Earthing complete with galvanised mild steel earth plate electrode 600x600x6mm thick, burried directly in ground to a depth not less than 2.25 metres deep below ground level with top edge of earth plate not less than 1.5 metre below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all around the plate, using GI strip 32 x 6 mm as earth strip electrode bolted or rivetted to earth plate at one end and connected at another end, GI earth strip encased in and including 40 mm dia GI 'light grade' pipe from upper end of earth plate upto equipments,20 dia bore GI pipe 'medium grade' as water pipe from earth chamber to upper edge of earth plate, GI funnel with wire mesh fixed on water pipe and PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in pit chamber and RCC pit cover 40mm thick precast RCC 1:2:4 type B-1, duly reinforced with 8mm dia TMT bars @ 150mm C/c and 6mm dia bars in lifting handles amd MS angle frame of angle iron 40x40x5 mm thick, excavation, earth work including laying the GI pipe concealed in floor/wall all as described in electric plate number 3 of SSR Part I complete all as specified and directed and testing on completion. Note :- If the desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department. The rate quoted against this item shall included protection pipe and earthing strip of 7.5 M long.
M&L Earthing complete with galvanised mild steel earth plate electrode 600x600x6mm thick, burried directly in ground to a depth not less than 2.25 metres deep below ground level with top edge of earth plate not less than 1.5 metre below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all around the plate, using GI strip 25 x 4 mm as earth strip electrode bolted or rivetted to earth plate at one end and connected at another end, GI earth strip encased in and including 40 mm dia GI 'light grade' pipe from upper end of earth plate upto equipments,20 dia bore GI pipe 'medium grade' as water pipe from earth chamber to upper edge of earth plate, GI funnel with wire mesh fixed on water pipe and PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in pit chamber and RCC pit cover 40mm thick precast RCC 1:2:4 type B-1, duly reinforced with 8mm dia TMT bars @ 150mm C/c and 6mm dia bars in lifting handles amd MS angle frame of angle iron 40x40x5 mm thick, excavation, earth work including laying the GI pipe concealed in floor/wall all as described in electric plate number 3 of SSR Part I complete all as specified and directed and testing on completion. Note :- If the desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department. The rate quoted against this item shall included protection pipe and earthing strip of 7.5 M long.
Cutting of wornout / burnt aluminium cable terminal lugs from the LT cable , crimping of new aluminium cable core and fixing with transformer, Panel MCCB terminal stud including cutting/ dressing of cable,disconnecting under ground cable from over head conductor , cutting down wornout portion under ground cables of any type and size for repairs including taking out under ground cable loop from ground and making connections of restoration of electric supply complete all as specified. Note:- Excavation, earth work , taking out cable protection covers, and sand cushion and relaying the same shall be deemed included in the unit rate quoted by Contractor)
M&L for preparation of old painted steel and iron surfaces of any description of panela, not otherwise describd over 10 cm width or girth including stopping and painting with one coat of synthetic enamel paint using spray gun complete all as specified and directed.
S&F in repair LED type indicator (RYB) complete assembly with holder suitable for 220V, 50 HZ complete all as specified and directed.
Taking down existing mild steel/ CRCA shutters of LT panel and repairing the same by welding and providing 100mm long medium weight mild steel hinges and 65mm size pad lock of brass of Make Godrej or equivalent incuding two coats of painting including preparation of steel surfaces complete all as spcified and directed.
S&F in repair 3.15mm thick CRCA steel shutters of LT panel duly fitted with 100 mm long mild steel medium weight butt hinges 02 Nos per leaf incl two coats of synthetic enamel paint over a coat of red oxide primer incl preparation of surfaces completee all as specified and directed. Note- Superficial area of shutter shall be measured for the purpose of payment
S&F in repair MCCB, 4 pole, 200 Amps,36KA, (Ics=100%Icu) 415 volts, 50 hz, AC , with adjustable thermal and fixed magnetic release duly connected with copper spreader links and proper size lugs, nuts, bolts and washers for proper connections, all as specified and directed.
S&F in repair MCCB, 4 pole, 160 Amps,36KA, (Ics=100%Icu) 415 volts, 50 hz, AC , with adjustable thermal and fixed magnetic release duly connected with copper spreader links and proper size lugs, nuts, bolts and washers for proper connections, all as specified and directed.
S&F MCCB, 4 pole, 250 Amps, 36 KA, (Icu=100% Ics), 415 volts, 50 hz, AC , with thermal adjustable and magnetic fixed release duly connected with proper size lugs, nuts, bolts and washers for proper connections, all as specified and directed.
S&F MCCB, 4 pole, 400 Amps, 36KA, , ( Icu=100% Ics) 415 volts, 50 hz, AC , with adjustable thermal release and fixed magnetic release duly connected with copper spreader links and proper size lugs, nuts, bolts and washers for proper connections, all as specified and directed.
Dismantling old userviceable LT distribution panel of any size and type complete all as specified and directed.
Ramesh Traders Govt Contractors & General OrderSuppliers
Shikha Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .