Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹99.4 LAccepted-Finance | ₹99.4 L | L-1 | Accepted-Finance Bidder is L-1 |
| 2 | L-2₹99.9 L+₹49,844 (0.50%)Rejected-Finance OLD JAIL ROAD NEAR JILA GARDEN RAJKOT 360001 | RAJKOT | GUJARAT | 360001 | ₹99.9 L+₹49,844 (0.50%) | L-2 | Rejected-Finance Bidder is not L-1 |
| 3 | L-3₹1.1 Cr+₹8.8 L (8.87%)Rejected-Finance | ₹1.1 Cr+₹8.8 L (8.87%) | L-3 | Rejected-Finance Bidder is not L-1 |
| 4 | L-4₹1.1 Cr+₹10.4 L (10.5%)Rejected-Finance | ₹1.1 Cr+₹10.4 L (10.5%) | L-4 | Rejected-Finance Bidder is not L-1 |
| 5 | L-5₹1.1 Cr+₹10.8 L (10.9%)Rejected-Finance KARNATAKA | RAICHUR | KARNATAKA | 584123 | ₹1.1 Cr+₹10.8 L (10.9%) | L-5 | Rejected-Finance Bidder is not L-1 |
| Sl No | Description | Qty | Unit | Power And Instrumentation Guj Ltd L3 | DOSHI ELECTRIC ENGG. CO. L2 | Jazzcon Engineers Pvt. Ltd. L7 | K B CONTRACT (P) LTD L4 | ECS ENGINEERING PVT LTD L5 | RISHA CONTROL ENGINEERS PRIVATE LIMITED L6 | Ankit Electricals L1 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00Supply, Installation, Testing and Commissioning of indoor LT Panel (TTA Type) suitable for 415V, 3-Phase, 4-Wire, 50 Hz., AC supply system fabricated in cubical type compartmentalized CRCA sheet steel of 2 mm thick for frame work and 3 mm thick for gland plated including cleaning and finishing complete with powder coating in approved shade, having 2000 Amp capacity extensible type 4- pole Aluminium alloy bus-bars of high conductivity, DMC/SMC bus bar supports with short circuit withstand capacity of 31 MVA for 1 Sec., bottom base channel of MS section of size not less than 100mm X 50mm X 5mm thick, fabrication shall be done in transportable sections, entire panel shall have a common GI earth bar of size 50mm x 5mm at the rear with 2 nos. earth stud, solid connections from main bus bar to switch gears with required size of Aluminuim busbars and control wiring with 2.5 sq.mm. FRLS PVC insulated copper conductor, cable alleys, cable gland plates in two half i/c. providing following switchgears :- | ||||||||||
| 1.10Incoming: i) 1250 Amps Four pole horizontal drawout type air circuit breaker of fault breaking capacity 50 KA (Ics=100%Icu) EDO, fitted with interlocked, Electrically and mechanically ON/OFF and service/test/isolated position indicators and frame earthing contact, conforming to IS:13947-2; 1993 as amended upto date complete with following accessories for each ACB.- 02 set ii) Independent electrical and mechanical spring closing mechanism . iii) Microprocessor release for over current, earth fault & short circuit protection - 02 Set. iv) Under voltage release - 02 set. v) CT's of ratio 1200 /5A, Class-0.5 accuracy-02 Set.(1 Set of 3 Nos.) vi) Digital Multifunction meter suitable to measure parameters V, A, F, PF, kW, kVA, kVAR, kWh, kVAh, kVARh, Run hours, THD with RS 485 port - 02 set . vii) Phase indication LED Lamps with 2 Amp. Protection MCB for ACBs- 02 Set ( 01 set of 03 Nos). viii) On/ Off LED Lamps with 2 Amp. protection MCB for ACBs-02 Set. | ||||||||||
| 1.20Bus coupler : i) 1250 Amps Four pole horizontal drawout type air circuit breaker of fault breaking capacity 50 KA (Ics=100%Icu) EDO, fitted with interlocked, Electrically and mechanically ON/OFF and service/test/isolated position indicators and frame earthing contact, conforming to IS:13947-2; 1993 as amended upto date complete with following accessories.- 1 set ii) Independent electrical and mechanical spring closing mechanism . iii) On/ Off LED Lamps with 2 Amp. protection MCB for ACBs- 01 Set. | ||||||||||
| 1.30Bus-Bars : 4-Pole Aluminium bus bars of minimum of 2000 Amps Capacity with heat shrinkable coloured sleeves including DMC /SMC bus bars supports at required intervals complete for cross section, size supports and their spacing etc. for with standing fault level of 31 MVA for 1-Sec. | ||||||||||
| 1.40 | Outgoings :
i) 630 Amp., 4 Pole, MCCB having variable current settings (Ics=100%Icu, 50 kA), spreader links and extendable ON/OFF rotary handle - 4 Nos. CT's of ratio 800/5 Amps, Class-0.5 - 4 Set (1 Set of 3 Nos.)
ii) 400 Amp., 4 Pole, MCCB having variable current settings (Ics=100%Icu, 50 kA) , spreader links and extendable ON/OFF rotary handle - 6 Nos. CT's of ratio 400/5 Amps, Class-0.5 - 6 Set (1 Set of 3 Nos.)
iii) 250 Amp., 4 Pole, MCCB having variable current settings (Ics=100% Icu, 35 kA), spreader links and extendable ON/OFF rotary handle - 8 Nos. CT's of ratio 250/5 Amps, Class-0.5 -8 Set. (1 Set of 3 Nos.)
iv) 125 Amp., 4 Pole, MCCB (Ics=35 kA upto 433 V), spreader links and extendable ON/OFF rotary handle - 8 Nos. CT's of ratio 125/5 Amps, Class-0.5 -8 Set. (1 Set of 3 Nos.)
v) Digital Multifunction meter suitable to measure parameters V, A, F, PF, kW, kVA, kVAR, kWh, kVAh, kVARh, Run hours, THD with RS 485 port - 26 Nos.
vi) On/ Off LED indication Lamps with 2 Amp. protection MCB.- 26 Set.
vii) C/O Auxiliary contact on each MCCB - 26 set | 1 | Job | 31,44,727 ₹31,44,727 | 32,00,000 ₹32,00,000 | 29,21,312 ₹29,21,312 | 26,10,000 ₹26,10,000 | 26,80,000 ₹26,80,000 | 28,37,000 ₹28,37,000 | 24,50,000 ₹24,50,000 Lowest |
| 2.00Desing, Supplying, Installation, Testing and Commissioning of section of existing indoor LT Panel suitable for 03 nos outgoing 415V, 3-Phase, 4-Wire, 50 Hz., AC supply system fabricated in cubical type compartmentalized CRCA sheet steel of 2 mm thick for frame work and 3 mm thick for gland plated including cleaning and finishing complete with powder coating in approved shade, having 2000 Amp capacity extensible type 4-pole Aluminium alloy bus-bars (approx length-5 mtr) of high conductivity, DMC/SMC bus bar supports with short circuit withstand capacity of 31 MVA for 1 Sec., bottom base channel of MS section of size not less than 100mm X 50mm X 5mm thick, fabrication shall be done in transportable sections, entire panel shall have a common GI earth bar of size 50 mm x 5mm at the rear with 2 nos. earth stud, solid connections from main bus bar to switch gears with required size of Aluminium busbars and control wiring with 2.5 sq.mm. FRLS PVC insulated copper conductor, cable alleys, cable gland plates in two half including providing following switchgears :- | ||||||||||
| 2.10 | Outgoings :
(i) 630 Amp, 4 Pole, MCCB having variable current settings (Ics=100%Icu, 50 kA), spreader links and extendable ON/OFF rotary handle - 1 Nos.
(ii) 400 Amp, 4 Pole, MCCB having variable current settings (Ics=100%Icu, 50 kA) , spreader links and extendable ON/OFF rotary handle - 1 Nos.
(iii) 250 Amp, 4 Pole, MCCB having variable current settings (Ics=100% Icu, 35 kA),
spreader links and extendable ON/OFF rotary handle - 1 Nos.
(iv) CT's with suitable ratio & Class-0.5 -03 Set (1 Set of 3 Nos.)
(v) Digital Multifunction meter suitable to measure parameters V, A, F, PF, kW, kVA, kVAR, kWh, kVAh, kVARh, Run hours, THD with RS 485 port - 03 Nos.
(vi) On/ Off LED indication Lamps with 2 Amp. protection MCB.-03 Set.
(vii) C/O Auxiliary contact on each MCCB - 03 set | 1 | Job | 2,94,028 ₹2,94,028 | 3,50,000 ₹3,50,000 | 5,57,840 ₹5,57,840 | 3,42,000 ₹3,42,000 | 2,60,000 ₹2,60,000 Lowest | 3,56,000 ₹3,56,000 | 2,79,000 ₹2,79,000 |
| 3.00 | Supplying, Installation, testing and Commissioning of 1250 Amps, Four pole horizontal drawout type air circuit breaker (ACB) of fault breaking capacity 50 KA (Ics=100%Icu) EDO, fitted with interlocked, Electrically and mechanically ON/OFF and service/test/isolated position indicators and frame earthing contact, conforming to IS:13947-2; 1993 as amended upto date, retrofit in existing LT panels including required accessories like base frame, UV release with delay setting controller etc complete as required.
Make- L & T Model- U-Power OMEGA UW1-12N Category-B or equivalent.
(The existing breaker is L&T Make of 800A and model-U-Power OMEGA UW1-08N Category-B) | 4 | Job | 2,17,087 ₹8,68,348 | 2,25,000 ₹9,00,000 | 2,35,000 ₹9,40,000 | 3,60,000 ₹14,40,000 | 1,77,600 ₹7,10,400 Lowest | 3,00,000 ₹12,00,000 | 2,95,000 ₹11,80,000 |
| 4.00 | Supply & Fixing of 4- Pole aluminium bus bars of 600 Amps capacity (minimum) on the bus bar of 1200 Amps in the existing LT Panel with heat shrinkable coloured sleeves and i/c. DMC / SMC bus bars supports at required intervals complete for cross section, size supports and their spacing, including suitable nut bolts etc. complete as per site requirement. | 21 | Mtr | 7,978 ₹1,67,538 | 2,000 ₹42,000 Lowest | 9,050 ₹1,90,050 | 9,000 ₹1,89,000 | 6,500 ₹1,36,500 | 5,500 ₹1,15,500 | 3,100 ₹65,100 |
| 5.00 | Supply, Installation, Testing & Commissioning of set of 3 Nos, Indoor RESIN CAST type Current Transformer ratio 1250/5, Class-0.5, burden 15VA etc. complete as required as per site requirement. | 4 | set | 1,515 ₹6,060 | 5,000 ₹20,000 | 3,175 ₹12,700 | 7,200 ₹28,800 | 4,000 ₹16,000 | 8,000 ₹32,000 | 1,000 ₹4,000 Lowest |
Tender Value
₹1.1 Cr
EMD Value
₹3.3 L
Closing Date
17 Jun 2026, 3:00 pmClosed
AGM (Engg-E)
O/o Airport Director Kishangarh Airport Kishangarh Ajmer.
Augmentation of power supply system of 33 kV Sub-station at Kishangarh Airport, Ajmer.
2026_AAI_278024_1
AAI/KSG/ENGG-E/ NIT-02/2026-27
Open Tender
Electrical Works
Item Rate
150 days
Kishangarh Airport
As per Tender Document.
20 documents required · 20 mandatory
₹1,180
₹3.3 L
5 Aug 2026
20 May 2026
18 Jun 2026
20 May 2026
17 Jun 2026
20 May 2026
20 May 2026 - 27 May 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Supply, Installation, Testing and Commissioning of indoor LT Panel (TTA Type) suitable for 415V, 3-Phase, 4-Wire, 50 Hz., AC supply system fabricated in cubical type compartmentalized CRCA sheet steel of 2 mm thick for frame work and 3 mm thick for gland plated including cleaning and finishing complete with powder coating in approved shade, having 2000 Amp capacity extensible type 4- pole Aluminium alloy bus-bars of high conductivity, DMC/SMC bus bar supports with short circuit withstand capacity of 31 MVA for 1 Sec., bottom base channel of MS section of size not less than 100mm X 50mm X 5mm thick, fabrication shall be done in transportable sections, entire panel shall have a common GI earth bar of size 50mm x 5mm at the rear with 2 nos. earth stud, solid connections from main bus bar to switch gears with required size of Aluminuim busbars and control wiring with 2.5 sq.mm. FRLS PVC insulated copper conductor, cable alleys, cable gland plates in two half i/c. providing following switchgears :- | |||||
| 1.1 | Incoming:
i) 1250 Amps Four pole horizontal drawout type air circuit breaker of fault breaking capacity 50 KA (Ics=100%Icu) EDO, fitted with interlocked, Electrically and mechanically ON/OFF and service/test/isolated position indicators and frame earthing contact, conforming to IS:13947-2; 1993 as amended upto date complete with following accessories for each ACB.- 02 set
ii) Independent electrical and mechanical spring closing mechanism .
iii) Microprocessor release for over current, earth fault & short circuit protection - 02 Set.
iv) Under voltage release - 02 set.
v) CT's of ratio 1200 /5A, Class-0.5 accuracy-02 Set.(1 Set of 3 Nos.)
vi) Digital Multifunction meter suitable to measure parameters V, A, F, PF, kW, kVA, kVAR, kWh, kVAh, kVARh, Run hours, THD with RS 485 port - 02 set .
vii) Phase indication LED Lamps with 2 Amp. Protection MCB for ACBs- 02 Set ( 01 set of 03 Nos).
viii) On/ Off LED Lamps with 2 Amp. protection MCB for ACBs-02 Set. | - | - | - | - |
| 1.2 | Bus coupler :
i) 1250 Amps Four pole horizontal drawout type air circuit breaker of fault breaking capacity 50 KA (Ics=100%Icu) EDO, fitted with interlocked, Electrically and mechanically ON/OFF and service/test/isolated position indicators and frame earthing contact, conforming to IS:13947-2; 1993 as amended upto date complete with following accessories.- 1 set
ii) Independent electrical and mechanical spring closing mechanism .
iii) On/ Off LED Lamps with 2 Amp. protection MCB for ACBs- 01 Set. | - | - | - | - |
| 1.3 | Bus-Bars :
4-Pole Aluminium bus bars of minimum of 2000 Amps Capacity with heat shrinkable coloured sleeves including DMC /SMC bus bars supports at required intervals complete for cross section, size supports and their spacing etc. for with standing fault level of 31 MVA for 1-Sec. | - | - | - | - |
| 1.4 | Outgoings :
i) 630 Amp., 4 Pole, MCCB having variable current settings (Ics=100%Icu, 50 kA), spreader links and extendable ON/OFF rotary handle - 4 Nos. CT's of ratio 800/5 Amps, Class-0.5 - 4 Set (1 Set of 3 Nos.)
ii) 400 Amp., 4 Pole, MCCB having variable current settings (Ics=100%Icu, 50 kA) , spreader links and extendable ON/OFF rotary handle - 6 Nos. CT's of ratio 400/5 Amps, Class-0.5 - 6 Set (1 Set of 3 Nos.)
iii) 250 Amp., 4 Pole, MCCB having variable current settings (Ics=100% Icu, 35 kA), spreader links and extendable ON/OFF rotary handle - 8 Nos. CT's of ratio 250/5 Amps, Class-0.5 -8 Set. (1 Set of 3 Nos.)
iv) 125 Amp., 4 Pole, MCCB (Ics=35 kA upto 433 V), spreader links and extendable ON/OFF rotary handle - 8 Nos. CT's of ratio 125/5 Amps, Class-0.5 -8 Set. (1 Set of 3 Nos.)
v) Digital Multifunction meter suitable to measure parameters V, A, F, PF, kW, kVA, kVAR, kWh, kVAh, kVARh, Run hours, THD with RS 485 port - 26 Nos.
vi) On/ Off LED indication Lamps with 2 Amp. protection MCB.- 26 Set.
vii) C/O Auxiliary contact on each MCCB - 26 set | 1 | Job | 100 | ₹100 |
| 2Desing, Supplying, Installation, Testing and Commissioning of section of existing indoor LT Panel suitable for 03 nos outgoing 415V, 3-Phase, 4-Wire, 50 Hz., AC supply system fabricated in cubical type compartmentalized CRCA sheet steel of 2 mm thick for frame work and 3 mm thick for gland plated including cleaning and finishing complete with powder coating in approved shade, having 2000 Amp capacity extensible type 4-pole Aluminium alloy bus-bars (approx length-5 mtr) of high conductivity, DMC/SMC bus bar supports with short circuit withstand capacity of 31 MVA for 1 Sec., bottom base channel of MS section of size not less than 100mm X 50mm X 5mm thick, fabrication shall be done in transportable sections, entire panel shall have a common GI earth bar of size 50 mm x 5mm at the rear with 2 nos. earth stud, solid connections from main bus bar to switch gears with required size of Aluminium busbars and control wiring with 2.5 sq.mm. FRLS PVC insulated copper conductor, cable alleys, cable gland plates in two half including providing following switchgears :- | |||||
| 2.1 | Outgoings :
(i) 630 Amp, 4 Pole, MCCB having variable current settings (Ics=100%Icu, 50 kA), spreader links and extendable ON/OFF rotary handle - 1 Nos.
(ii) 400 Amp, 4 Pole, MCCB having variable current settings (Ics=100%Icu, 50 kA) , spreader links and extendable ON/OFF rotary handle - 1 Nos.
(iii) 250 Amp, 4 Pole, MCCB having variable current settings (Ics=100% Icu, 35 kA),
spreader links and extendable ON/OFF rotary handle - 1 Nos.
(iv) CT's with suitable ratio & Class-0.5 -03 Set (1 Set of 3 Nos.)
(v) Digital Multifunction meter suitable to measure parameters V, A, F, PF, kW, kVA, kVAR, kWh, kVAh, kVARh, Run hours, THD with RS 485 port - 03 Nos.
(vi) On/ Off LED indication Lamps with 2 Amp. protection MCB.-03 Set.
(vii) C/O Auxiliary contact on each MCCB - 03 set | 1 | Job | 100 | ₹100 |
| 3 | Supplying, Installation, testing and Commissioning of 1250 Amps, Four pole horizontal drawout type air circuit breaker (ACB) of fault breaking capacity 50 KA (Ics=100%Icu) EDO, fitted with interlocked, Electrically and mechanically ON/OFF and service/test/isolated position indicators and frame earthing contact, conforming to IS:13947-2; 1993 as amended upto date, retrofit in existing LT panels including required accessories like base frame, UV release with delay setting controller etc complete as required.
Make- L & T Model- U-Power OMEGA UW1-12N Category-B or equivalent.
(The existing breaker is L&T Make of 800A and model-U-Power OMEGA UW1-08N Category-B) | 4 | Job | 100 | ₹400 |
| 4 | Supply & Fixing of 4- Pole aluminium bus bars of 600 Amps capacity (minimum) on the bus bar of 1200 Amps in the existing LT Panel with heat shrinkable coloured sleeves and i/c. DMC / SMC bus bars supports at required intervals complete for cross section, size supports and their spacing, including suitable nut bolts etc. complete as per site requirement. | 21 | Mtr | 100 | ₹2,100 |
| 5 | Supply, Installation, Testing & Commissioning of set of 3 Nos, Indoor RESIN CAST type Current Transformer ratio 1250/5, Class-0.5, burden 15VA etc. complete as required as per site requirement. | 4 | set | 100 | ₹400 |
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 1.47 MB
Tenderdocpowerh.pdf
Tender Documents • 5.21 MB
BOQ_324670.xls
BOQ • 0.31 MB
CorrigendumAugmentation.pdf
PDF • 0.16 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .