| 1 | L1₹18.0 LAccepted-AOC 3RD FLOOR VVIP RESIDENCY MAHINDER VIHAR CHAKRATA RD NEAR RAMADA HOTEL DEHRADUN UTTARAKHAND 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | L1 | Accepted-AOC Lowest | |
| 2 | L2₹18.8 L+₹42,928 (2.33%)Rejected-Finance | L2 | Rejected-Finance High Rate | |
| 3 | L3₹19.6 L+₹1.2 L (6.44%)Rejected-Finance | L3 | Rejected-Finance High Rate |
Tender Value
Refer Docs
EMD Value
₹55,960
Closing Date
6 Jan 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer (Central) Pune
Garrison Engineer Central Arjun Marg Pune 411001
8207 REPAIRS MAINTENANCE SERVICING TO SUMMER APPLIANCES AND WALK IN COOLERS AT AFMC AIPT ASI AND OTHER UNITS IN OLD NDA CAMPUS AREA UNDER GE CENTRAL PUNE
2020_MES_401629_1
8207 E8 REPAIR MAINTENANCE SERVICING TO SUMMAR
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Garrison Engineer (Central) Pune
As per tender
9 documents required · 9 mandatory
₹500
Garrison Engineer (Central) Pune
₹55,960
Yes
23 Jan 2021
8 Dec 2020
8 Jan 2021
8 Dec 2020
6 Jan 2021
23 Dec 2020
60 days
Amount
Taking down carefully old unserviceable, burnt out sealed unit compressor by means of unscrewing foundation nut bolts, disconnecting from suction & discharge side mechanically & electrically, of any make and keeping a side for further disposal as directed by Engr-in-Charge for the following :-
Refrigerator of capacity 165/175/192 Ltrs of any make.
Refrigerator of capacity 280/300/310 Ltrs of any make.
Water cooler of capacity 40/80 Ltrs of any make.
Water cooler of capacity 120/150 Ltrs of any make.
Deep Freezer of any capacity of any make.
Window type & split type AC of capacity 1.5/2/2.5/3 TR of any make.
Suuply and fix new sealed unit compressor of approved make and capacity, 230 VAC, all as specified and directed by the Engineer-in-Charge for the following capacities.
Compressor for refrigerator of capacity 165/175/192 Ltrs.
Compressor for refrigerator of capacity 280/300/310Ltrs.
Compressor for water cooler of capacity 40/80 Ltrs .
Compressor for water cooler of capacity 120/150 Ltrs.
Compressor for deep freezer of capacity 320/400 Ltrs.
Compressor for Window type & split type AC of capacity 1.5 TR.
Compressor for window type & split type AC of capacity 2 TR.
Compressor for Split type AC of capacity 2.5 TR, 3phase 440VAC.
Compressor for Split type AC of capacity 3.0 TR, 3phase 440VAC.
Taking out old unserviceable thermostat and S&F new thermostat of approved make and suitable size & model for the following :-
Auto 'D' thermostat No 1027 with knob for refrigerator or equivalent.
Thermostat No 2064 with knob for water coller or equivalent.
Thermostat No 2059 with knob for window type AC or equivalent.
Thermostat with knob for suitable for deep freezer of any capacity.
Taking out old unserviceable relay unit and supply and fix new relay kit (OLP + LMS relay or box type) as per sample for refrigerator.
Taking out old unserviceable relay kit and S&F new relay kit as per sample for water cooler, No 412Y/512Y or equivalent.
Taking out old unserviceable relay of any type and S&F new potential box type relay/PTC relay of suitable model for window/split type AC/deep freezer.
Taking out old/burnt starting capacitors and S&F new starting capacitor of following capacities as per sample :-
Starting capacitor 40 to 60 MFD.
Starting capacitor 60 to 80 MFD.
Starting capacitor 80 - 100 MFD.
Starting capacitor 100 - 120 MFD.
Taking out old/burnt running capacitors and S&F new running capacitors of following capacities as per sample :-
Running capacitor 10/15/25 MFD.
Running capacitor 36 MFD.
Running capacitor 45 MFD.
Running capacitor 55+6 MFD.
Taking out old/burnt fan motor capacitors and S&F new fan motor capacitors as per sample.
Taking out old unserviceable/broken knobs and S & F new knobs for window type AC/desert cooler of any capacity.
M&L in replacement of unserviceable/leakage cooling coil complete suitable for existing model of refirigerator for the following :-
Refrigerator of capacity 165/175 Ltrs.
Refrigerator of capacity 286/300/ Ltrs.
M&L in replacement of unserviceable/rusted condensor complete suitable for existing model of refirigerator for the following :-
Refrigerator of capacity 165/175 Ltrs.
Refrigerator of capacity 286/300/ Ltrs.
M&L in replacement of broken freezer door complete with casing and lock nut as per sample for refrigerator of any capacity.
M&L in replacement of vegetable tray complete suitable for existing model of refrigrator of any capacity.
M&L in replacement of chiller tray complete suitable for existing model of refrigerator of any capacity.
M&L in replacement of metal shelf powder coated suitable for existing model of refrigerator of any capacity.
M&L in replacement of bulb pintype/thread type suitable for existing model of refrigerator of any capacity.
M&L in replacement of broken door panel gasket complete suitable for existing model of refrigeratior of any capacity.
M&L in replacement of burnt out condenser fan motor, single shaft 1/35, HP capacity, single phase, 230 VAC for water cooler.
M&L in replacement of burnt out condenser fan motor, single shaft 1/83 HP capacity, single phase, 230 V , AC for water cooler.
M&L in replacement of burnt out condenser fan motor, single shaft 1/10 HP capacity, single phase, 230 V , AC for water cooler.
M&L for checking of drain water tray for leakage & getting the same repaired by soldering all the sides of the tray including making proper provision for fitting of grating to the tray to make it functional as directed by Engineer-in-charge.
M&L in replacement of unserviceable push cock, 15 mm dia for water cooler.
M&L in replacement of unserviceable stop cock, 15 mm dia for water cooler.
S&F fan blade (As per sample) in replacement for water cooler/ deep freezer of any capacity
Taking out old unserviceable/broken float valve and S & F new float valve complete for water cooler of any capacity.
S & F in replacement of 600mm long PVC connection pipe 15mm size with PTMT nuts complete all as specified and directed.:-
Taking out old broken PVC flexible drain outlet pipe and S & F new drain outlet pipe 32/40mm dia complete for water cooler of any capacity as directed by Engineer-in-charge.
M&L for repair/replacement of corroded bottom portion of the water cooler of any make & capacity with MS angle iron of suitable size as per existing, including welding/brazing with MS sheet 1.6mm thick at the base of water cooler for mounting of compressor, blower motor, etc complete all as directed by Engineer-in-charge.
M&L for replacement of old wornout/burnt wiring of water cooler/ deep freezer by using copper conductor wire PVC sheathed of suitable size and length complete all as directed by Eng-in-charge.
-Ditto- all as per item No. 31 but for window/split type A/C of any capacity.
Taking out burnt/unserviceable fan/blower motor of window type AC of any type & capacity and S&F new fan/blower motor double shaft single/double speed, single phase, 230 V , AC of 1/4HP, 1/5HP, 1/6HP or any other capacity as required complete, making suitable fixing arrangment for existing place (as per sample) Make - AUE/Fracmaster/Popular.
S&F fan blade (As per sample) in replacement for window type AC/split type AC/Desert Cooler of any capacity.
M&L for taking out old broken drain outlet pipe of any type attached to indoor unit of split type AC and S & F new drain outlet PVC pipe 20mm dia from indoor unit to nearest suitable drain outlet for split type AC of any capacity as directed by Engineer-in-charge.
S & F new door handle as per sample in replacement of old broken handle of Deep Freezer as directed
S & F new door gasket in replacement of old unserviceable door gasket of Deep Freezer of any capacity.
S & F new 5Amp pin top in replacement of old broken pin top of any make as directed.
S & F new 15Amp pin top in replacement of old broken pin top of any make as directed.
M&L in replacement of blower of window type air conditionor suitable for 1.5/ 2 TR capacity as per sample.
S&F coir/Mesh air filter of suitable size for window type AC.
M&L in replacement of air filter made out of nylon wire mesh moulded in plastic complete suitable for existing old filter's size and shape, as directed for 1.5/2 TR capacity of split type AC.
M&L in replacement of broken/damage front grill assembly complete suitable for existing model of window AC of any capacity.
S&F MCB, SP20- 32 Amps,10 KA ,230 V, 'C'series in replacement of old damage/broken MCB SP.
S&F MCB, SPN, 40 Amps,10 KA ,230 V, 'C'series in replacement of old damage/broken MCB SPN
S & F MCB TPN, 415 Volts, 60 Amps,10 KA ,230 V, 'C'series
S&F DP indicator switch, 32 Amps in replacement of old damage/broken DP indicator switch 32 Amp.
M&L for replacement of burnt out sub main wiring complete with two single core 4 sqmm,1100volts grade, PVC insulated, stranded copper conductor cable with continuous copper earth conductor of 2.5 sqmm in and including PVC casing caping complete.
S&F in replacement of sheet metal enclosure with socket plug top & MCB ,single pole & Neutral enclosure with a two pin and earth plug & socket complete with one single pole MCB 20 Amps.
S&F in replacement of 3 pin sheet metal enclosure plug suitable for industrial metal clad socket, single phase 230 volts AC complete all as directed.
M&L for gas charging with F-22 or R-134(a) gas as required quantity including all allied works such as vaccumising the complete system, leak test, pressure test, replacement of copper filters, copper capillary tube, copper tubing of suitable size and required length complete with testing and commissioning for the followings :-
Refrigerator of any capacity & make.
Water cooler of any capacity & make.
Deep Freezer of any capacity & make.
Window type AC of 1.5/2 TR capacity.
Split type AC of 1.5/2 TR capacity.
Split type/Cassette type AC of 2.5/3 TR capacity
M&L for replacement of copper tubing, confirming to relevant IS, of 5/8" and 3/8" flare size, or nearest size, 3 core 2.5sqmm copper cable, PVC drain pipe and insulation with superior insulation to copper tubing as required length from indoor to outdoor unit of split AC complete as directed bu Engineer in charge.
Servicing only window type AC complete with chemical wash to condenser and cooling coil, cleaning of entire elements of AC, oiling/greasing to motor including taking out & refixing the machine at its original location as directed by Engineer-in-Charge.
M&L for disconnecting the water cooler of capacity of any capacity from electric and water connection. Cleaning the condensor unit by using carbon tetra chloride cleaning the condensor fins, oiling/greasing the fan motor, checking of alignment of motor cleaning of water storage tank. Fixing back the water cooler and testing all as directed by Eng-in-charge.
M&L for servicing the deep freezer unit completely for trouble free working and satisfactory performance by means of cleaning each part of the machine carefully, greasing/oiling every moveable part, cleaning the condenser and cooling coil complete with the help of wire brush, soda wash and pressure air through blower and cleaning the machine for better working as directed.
M&L for removing Air cooler/ desert cooler any size and capacity from site, dismantling the worn out fan motor, supply and fixing of new suitable motor in position. Including testing and commissioning complete all as directed by Eng-in-charge.
M&L for removing pump motor set of Air cooler/desert cooler of any size and capacity. S&F new pump motor submersible type single phase AC , 230 Volts , 50 Hz of suitable capacity and size all as directed by Eng-in-charge.
M&L for replacement of PVC water tube and distribution with 3 way PVC connection assembly complete for Air cooler/desert cooler of any size and capacity all as directed by Eng-in-charge.
M&L for replacement of caster wheels (set of four) complete for Air cooler/desert cooler of any size and capacity all as directed by Eng-in-charge.
M&L for replacement of switch assembly complete for Air cooler/desert cooler of any size and capacity all as directed by Eng-in-charge.
M&L in replacement of wooden fiber(one set of three) of air/desert cooler of any capacity all as per direction of Eng-in-charge.
M&L for replacement of old wornout wiring of desert cooler by using copper conductor wire PVC sheathed of suitable size and length complete all as directed by Eng-in-charge.
M&L for taking out the desert cooler from the site, dismantling the parts of desert cooler, cleaning of distribution pipe for proper water spray on pads, oiling the fan motor & pump motor complete & reassembling & fixing in position all as per direction of Eng-in-charge.
Taking down unserviceable/damage wall mounted cooling coil unit of split type AC complete by means of disconnecting electrical connection and suction and discharge pipe line and S&F new cooling coil unit of suitable capacity of existing dismantled model or equivalent approved by Engineer-in-Charge including remote control, proper fixing on wall, connect to electrical system and connect to suction and discharge pipe line, drain water pipe line as directed and testing and commissioning complete for satisfactory performance of unit after gas charging of following capacity.
Suitable for 1.5 TR capacity, split AC, 230VAC.
Suitable for 2 TR capacity, split AC, 230VAC.
Suitable for 3 TR capacity, split AC, 230VAC.
Taking down unserviceable/damaged/rusted condensor unit of split type AC complete by means of disconnecting electrical connection and suction and discharge pipe line and S&F new condensor unit consisting of body, motor, condensor & blade suitable for existing dismantled model or equivalent approved by Engineer-in-Charge and connect to suction and discharge pipe line to compressor after refixing compressor of existing unit as directed and testing and commissioning complete for satisfactory performance of unit after gas charging of following capacity.
Suitable for 1.5 TR capacity.
Suitable for 2 TR capacity.
Suitable for 3 TR capacity.
Taking down unserviceable wall mounted cooling coil unit complete of 1.5/2TR capacity by means of disconnecting electrical connection and suction /discharge pipe line, testing it for leakage of gas and repair it by means of brazing, again testing for leakage of gas and connecting electrical connections and suction/discharge pipe line, drain water pipe line,etc complete as directed.
M&L for replacement of 3 core, 4 sqmm, copper conductor PVC insulated flexible cable from main supply point to out door unit point as directed and specified by Engineer-in-Charge.
All as per item No.67 above but 3 core , 2.5 Sqmm.
All as per item No.67 above but 3 core , 1.5 Sqmm.
All as per item No.67 above but 4 core , 6 Sqmm.
M&L for replacement of 5/8" and 3/8" or nearest tube size insulation with superior insulation to copper tubing as required length from indoor to outdoor unit of split AC complete as directed by Engineer in charge after taking down old, deteriorated insulation.
S&F single pole contactor of suitable model and size for 1.5/2 TR split type AC as per sample.
S&F 3 pole power contactor 25Amp,220VAC for 3TR split type AC as per sample.
S&F long shaft (Double) indoor unit motor (blower) of suitable HP, as per site requirement, for cooling coil of capacity 1.5/2 TR split AC complete as directed by Engineer-in-Charge.
S&F in replacement single shaft, blower motor of 1/6,1/8,1/5 HP capacity for split type AC of capacity 1.5/2 TR/Air Curtain of any size complete as directed by Engineer-in-Charge Make - AUE, Fracmaster, Popular.
S&F in replacement swing motor for split type AC of any capacity complete as per sample as directed by Engineer-in-Charge.
S&F in replacement Expansion Valve TEX2 suitable for 3TR cassete type split AC as per sample as directed by Engineer-in-Charge.
M&L for replacement of unserviceable remote control with PC board complete suitable for existing model of split AC of 1.5/2/2.5 TR capacity as directed by Engineer-in-Charge, make as per sample.
M&L for checking of remote control with PC board complete for its workability for split type AC of any capacity, removing the same & taking it to the workshop for repairs, Refitting it after the repairs to its original location as directed by Engineer-in-Charge.
Supply only suitable remote control handset of split type AC of any capacity in replacement of old unserviceable remote control handset of any type as specified and directed.
Supply and Fix in replacement service valve of size 5/8", 1/2" or nearest size suitable for split type AC of any capacity as specified and directed.
Supply and Fix in replacement brass flare nut of size 5/8", 1/2" or nearest size suitable for split type AC of any capacity as specified and directed.
M&L in replacement of blower of indoor unit of split type air conditionor suitable for 1.5/ 2 TR capacity as per sample.
Servicing only for split type AC of any capacity, including chemical wash or equivalent, to condenser and cooling coil, cleaning the entire parts, oiling/greasing to condenser motor, cooling coil blower motor complete as directed by Engineer-in-Charge.
Servicing only for cassette type AC of any capacity including chemical wash or equivalent, to condenser and cooling coil, cleaning the entire parts, oiling/greasing to condenser motor, cooling coil blower motor complete as directed by Engineer-in-Charge.
S & F in replacement factory made angle iron stand for outdoor unit of split type ACs of any capacity as directed & specified.
M&L for taking out the Air Curtain of any size from the wall above the door, cleaning the blower complete, & refixing in position all as per direction of Eng-in-charge.
M&L for removing of old unserviceable stabilizer of capacity 5KVA from the site, transporting it to the workshop, replacement of unserviceable spares such as control transformer, main transformer, voltmeter, relay, control board, etc as required and getting back the stabilizer at site and fiixing at the same position and checking it for its workablility as specified and directed.
M&L for removing of old unserviceable stabilizer of capacity 4KVA from the site, transporting it to the workshop, replacement of unserviceable spares such as control transformer, main transformer, voltmeter, relay, control board, etc as required and getting back the stabilizer at site and fiixing at the same position and checking it for its workablility as specified and directed.
M&L for cutting the existing window including additions/alterations to make opening suitable for fixing the window type air conditioner including welding/wood work as per site requirement to match with adjoining/existing surfaces and shifting the window type air conditioner to the new altered location/existing including the necessary connections and testing complete all as directed by Engineer-in-charge.
Labour only for removing/reinstallation of split type AC 1.5/2TR cap, indoor & outdoor unit including all allied work such as bending, shaping, brazing to copper tubing & insulation to tubing, connection of water drain piping & fixing it properly, etc including testing & commissioning complete.
S&F in replacement of indoor discharge fan with for walk-in cooler of following size as directed by Enginner- in- charge:-
Taking out the unserviceable sealed unit compressor from the Cold Storage Plant of any make & capacity by means of cutting to suction & discharge pipe line, disconnection from electric supply foundation nut bolts,etc and keeping aside as directed and supply and fix new sealed unit compressor of approved make and capacity, all as specified and directed by the Engineer-in-Charge for the following.
Cold storage of 2TR capacity.
Cold storage of 4TR capacity.
S&F in replacement of HP/LP cut off, KP-15 Make - Danfoss/Indfoss for Walk-in-Cooler of any type.
S&F in replacement Drier filter of 5/8", 3/8", 1/2" flare size or other nearest flare size Make - Sporlon/Catchall or equivalent.
S & F in replacement of Digital Sub-zero thermostat suitable for the cold storage & programe the thermostat for auto cut-off including all wiring complete as directed by Engineer-in-charge.
Vacummising the complete system of walk-in cooler with double stage vaccum pump of 2kg/cm2 and charging with nitrogen gas upto 250-300 PSI the complete system for leak testing and maintaining the pressure for 24 hrs and rectifying the leakage, if any in the system and after that charging the system with F-22 gas as required quantity as directed by Enginner-in-charge.
SUNIT TRADING CORPORATION
M/s. ANAND ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .