Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.7 LAccepted-AOC 47 VED NAGAR COLONY DEORI ROAD AGRA 282 001 | AGRA | AGRA | UTTAR PRADESH | 282001 | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹9.7 L+₹1.0 L (11.6%)Rejected-Finance | L2 | Rejected-Finance Not Lowest bidder | |
| 3 | L3₹9.7 L+₹1.0 L (11.9%)Rejected-Finance | L3 | Rejected-Finance Not Lowest bidder | |
| 4 | L4₹10.7 L+₹2.0 L (22.7%)Rejected-Finance LIG 10 VIVEK NAGAR NAVIBAGH BHOPAL MADHYA PRADESH 462038 | BHOPAL | MADHYA PRADESH | 462038 | L4 | Rejected-Finance Not Lowest bidder |
Tender Value
₹14 L
EMD Value
₹28,000
Closing Date
19 May 2022, 6:00 pmClosed
Garrison Engineer Dronachal
GE Dronachal, Dronachal Top, Neori Hills, Bhopal 462038
REPAIR AND MAINTENANCE OF SUMMER APPLIENCES AND CENTRAL AC INCLUDING AHU AT DSCC AYODHYA NAGAR BHOPAL
2022_MES_518997_1
8683/E8
Open Tender
Civil Works
Item Rate
180 days
Bhopal
Class-E, Category c (i) and as per NIT documents
6 documents required · 6 mandatory
₹500
Garrison Engineer Dronachal
₹28,000
Yes
16 Jun 2022
20 Apr 2022
21 May 2022
20 Apr 2022
19 May 2022
4 May 2022
Amount
M & L for servicing of split type AC of capacity 1.5 /2 TR of any by cleaning of filter on front side including fins, checking of refrigerant standing pressure, topping of refrigerant upto the required level, complete all as directed by Engineer-in-Charge. Note : Refrigerant required for topping (R22 / 134) shall be measured and paid for separately as "supply only rates" under respective item.
Replacement of following unserviceable item in Split type AC 1.5/2 TR :-
Supply only Blade for condensing fan motor
Supply only Running Capacitor 45 Mfd
Supply only Running Capacitor 6 Mfd
S & F in repairs running capacitor (ISI Marked), 36 Mfd suitable for AC of capacity 1.5/2 TR. Complete all as directed.
S & F in repairs starting capacitor, 100-120 Mfd suitable for AC of capacity 1.5/2 TR. Complete all as directed.
S&F in repairs PVC fan blade suitable for condenser of split type AC of 1.5/2 TR capacity.
S&F in repairs cooling fan motor of split type AC of 1/30 or 1/35 HP capacity of make Carrier / Hitachi / Voltage / Blue star, all as directed by Engineer-in-Charge.
S&F in repairs cooling blower fan motor of split type AC of 1/30 or 1/20 HP capacity of make Carrier / Hitachi / Voltage / Blue star, all as directed by Engineer-in-Charge.
S&F Foam type insulating flexible pipe & air tight outer tapping fitted on ACs of any capacity for suction / discharge copper tubes.
S&F in repairs wall mounted indoor Voltage Stabilizer automatic operation single phase and designed for input variation between 170 V to 250 Volt with output voltage stabilized at 230 V with accuracy of +2.5% and of capacity 5 KVA.
S&F in repairs wall mounted indoor Voltage Stabilizer automatic operation single phase and designed for input variation between 170 V to 250 Volt with output voltage stabilized at 230 V with accuracy of +2.5% and of capacity 4 KVA.
Supply & fixing single pole and neutral enclosure with a two pin and socket complete with one single pole MCB 240 volts, 20 Amps
S&F in repairs Rotary type Compressor (Sealed Unit) of window / split type AC 1.5 TR capacity, single phase, 220 volt of make Kirloskar / Tecumseh / Carrier including necessary modification of foudation as required to suit the comptessor, vacumisation, pressure testing, leakage rectification including gas charging R-22/134 & testing complete to the entire satisfaction of Engr-in-charge & depositing the old compressor in E/M store yard.
S&F in repairs Rotary type Compressor (Sealed Unit) of window / split type AC 02 TR capacity, single phase, 220 volt of make Kirloskar / Tecumseh / Carrier including necessary modification of foudation as required to suit the comptessor, vacumisation, pressure testing, leakage rectification including gas charging R-22/134 & testing complete to the entire satisfaction of Engr-in-charge & depositing the old compressor in E/M store yard.
S&F in repairs Rotary type Compressor (Sealed Unit) of refrigerator 165/175 ltr capacity, single phase, 220 volt of make Kirloskar / Tecumseh / Carrier including necessary modification of foudation as required to suit the comptessor, vacumisation, pressure testing, leakage rectification including gas charging R-22/134 & testing complete to the entire satisfaction of Engr-in-charge & depositing the old compressor in E/M store yard.
Supply and top up of Refrigerant gas R 22 in company sealed cylender of capacity all as directed by Engr-in-charge
Supply and top up of Refrigerant gas R 134 in company sealed cylender of capacity all as directed by Engr-in-charge
Supply and fix PCB for split type AC of capacity 1.5/2 TR all as per directed by EIC.make as per site requirment
M&L for cleaning after taking down complete body including fitting and fixture of desert cooler of capacity 4000/5000 cum/hours of any make with wire including removal of all sludge, loose paint dirt etc and preparationand cleaning of surface for painting and applying two coats of synthetic enamel spray paint inside and out side surfaces and applying two coats rubber seal paint inside the water tank, and rewriting of MES No. etc. Complete all as directed by Engr-in-Charge.
S&F in repairs PVC flexible pipe 16mm outer dia complete with PVC elbow etc.
S&F in repairs wood wool pad (set of three), minimum weight 0.8 Kg, fixed in side panels of desert coolers including GI wiremesh of 20 Gauge wire and mesh size 100 x 100 mm complete all as directed .
S&F in repairs switch piano type 250 Volts, single pole one ways 5 amps, fixed in desert coolers.
S&F in repairs capacitor 4 MFD for fan motors of desert coolers.
S& F in repairs Sub merrgible pump 230 volts suitable for desert cooler of capacity 4000/5000 including necessary wiring complete all as directed. Make Crompton/ Khaitan / Cool home
S & F in repairs side shutter (set of three) made out from 24 guagethick galvanized iron sheet suitable for 4000/5000 cum/hrs capacity desert coolers complete all as directed.
S&F in repairs float valve high pressure of PTMT with epoxy coated aluminum rod and high density plastic ball, screwed for 15mm bore iron pipe, weight not less than 142gm/each. Complete all as directed.
S & F in repairs Aluminium fan blade for fan motor of desert cooler 300 mm sweep.
S & F in repairs PVC, 3 way distributor suitable for 15 mm pipe with nut/ screws all as directed.
S & F in repairs desert cooler body of size 60x55x65 cm made out of 20 gauge GI sheet & water storage tank of soze 65x55x20 cm deep made out of 18 gauge GI sheet including front grills & three side shutters duly fitted with wood pads & duly spray painted with two coats of synthetic enamel paint over a coat of red oxide primer (inside & outside) all as directed by Engr-in-charge.
S & F in repair desert cooler fan motor 3 speed copper winding ISI mark including suitable leg set of three including nut bolt washer all as directed.
S & F wooden scantling second class hard wood of size 50X50 mm and making frame and fix with screw and nail for supporting to desert cooler.
S & F ply wood with commercial face of 5 ply 6mm thick BWR grade for packing of AC and Disert cooler all as directed.
M&L for sub main wiring with two runs of 4 sqmm single core PVC insulated but unsheathed FRLS copper conductor 1100V drawn through and including rigid heavy duty PVC conduit 25 mm dia with conduit accessories including 2.5 sqmm PVC insulated but unsheathed FRLS copper conductor used as earth wire all as directed by EIC
Supply and lay PVC pipe 20 mm dia with fittings in repair fixed on wall / ceiling.
M&L for complete servicing of AHU unit of various capacity installed in DSCC Bhopal including replacement of defective parts as under after removing and refixing of insulations etc and testing comissioning of plant after replacement of spares completed all as specified and directed by Engineer in Charge
Supply and fixing fan belts of AHU of size B-42 (Make: Dunlop) as per existing size after removing the defective worn out fan belt.
Supply and fixing fan belts of AHU of size A-44 (Make: Dunlop) as per existing size after removing the defective worn out fan belt.
Supply and fixing fan belts of AHU of size A-55 (Make: Dunlop) as per existing size after removing the defective worn out fan belt.
Supply and fixing fan belts of AHU of size B-78 (Make: Dunlop) as per existing size after removing the defective worn out fan belt.
Supply and fixing fan belts of AHU of size B-90 (Make: Dunlop) as per existing size after removing the defective worn out fan belt.
M&L for repair and rewinding of blower motor of capacity 7.5 HP/5.5 after taking out from its existing location, transporting to work shop, removing defective burnt wiring, rewinding of motor with new copper wire of suitable gauge including replacement of insulation paper, baking, heating , varnishing of winding, replacement of bearing, any machining and lath work as required, replacement of hardware as required etc and refixing it in existing location, testing comissioning complete up to the satisfaction of engineer in charge. Make of motor:- Bharat Bijili Ltd.
Supply and fixing in replacement relay contactor, 3 Pole power contractor type MNX , of AC 3 rating 25 Amp, AC1 rating 45 Amp.
Supply and fixing in replacement relay contactor,4 Pole power contractor type MCX
Supply and fixing in sensor for 65 TR chillar plant as per existing make and model.
Supply & fixing MCCBs for Motor back-up Protectione TYPE 440 volt AC, 50 Hz, 3 pole, rupturing capacity 35 KA of capacity 63 Amps.
All as per Item No.45.00 but 250 Amps 36 ka
All as per Item No.45.00 but 630 Amps 36 ka
MODI CORPORATION
CREATIVE CONSTRUCTION
PRAGATI ELECTRICALS AND ELECTRONICS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .