Loading…
Loading…
| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹14.7 LQualified Make: Anritsu
Model: Anritsu & S332E+15NNF50-1.5C+OSLN50A-8 204 CONVERGENT TECHNOLOGIES 2ND MAIN MAHALAKSHMI LAYOUT BANGALORE KARNATAKA 560086 | BENGALURU URBAN | KARNATAKA | 560086 | Make: Anritsu
Model: Anritsu & S332E+15NNF50-1.5C+OSLN50A-8 | L1 | Qualified | |
| 2 | Disqualified Make: Keysight Technologies
Model: Keysight N9912A with frequency range 4GHz CAT Spectrum Analyzer E 366 2ND FLOOR NIRMAN VIHAR VIKAS MARG VIKAS MARG VIKAS MARG NEW DELHI DELHI 110092 | EAST DELHI | DELHI | 110092 | Make: Keysight Technologies
Model: Keysight N9912A with frequency range 4GHz CAT Spectrum Analyzer | - | Disqualified | |
| 3 | Disqualified Make: Rohde & Schwarz
Model: R&S Spectrum Rider FPH PLOT NO 3 7 H NO 4 10 003 1ST FLOOR RAMDAS GARDEN WEST MARREDPALLY SECUNDERABAD TELANGANA 500026 | HYDERABAD | TELANGANA | 500026 | Make: Rohde & Schwarz
Model: R&S Spectrum Rider FPH | - | Disqualified | |
| 4 | Disqualified Make: Anritsu
Model: Anritsu & S332E+15NNF50-1.5C+OSLN50A-8 H NO W 4 NEAR SHAHDARA NURSING HOME NAVEEN SHAHDARA NEW DELHI NEW DELHI DELHI 110032 | SHAHDARA | DELHI | 110032 | Make: Anritsu
Model: Anritsu & S332E+15NNF50-1.5C+OSLN50A-8 | - | Disqualified | |
| 5 | Disqualified Make: Rohde & Schwarz
Model: Rohde & Schwarz FSH4 A27 FIRST FLOOR MOHAN CORPORTAIVE INDUSTRIAL ESTATE MATHURA ROAD NEW DELHI DELHI 110044 | SOUTH EAST DELHI | DELHI | 110044 | Make: Rohde & Schwarz
Model: Rohde & Schwarz FSH4 | - | Disqualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
19 Sept 2018, 10:00 amClosed
Spectrum Analyzers Vector Network Analyzers ( 2 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values FEATURES Description of the itemuu Spectrum analyzers Spectrum analyzers GENERAL FEATURES COMMON TO SPECTRUM AND VECTOR ANALYSER Markers Normal
delta * Trigger Free run
video
External * Display TFT Colour display with provision for three traces * Interface USB * Software for transfer of screen shot/measurement data to PC Yes * SPECTRUM ANALYZER FEATURES Frequency Range 9 kHz to 3 GHz 9 kHz to 3 GHz Aging rate of spectrum analyzer frequency: Better than 1x10-6 Year Yes * Frequency counter 1 * 1/6 Resolution(minimum) (Hz) Frequency Span 100Hz to 3GHz * Spectral purity:SSB Phase Noise @10KHz offset shall be less than -90dBc/Hz at 1GHz Yes * Spectral purity:Harmonics @ -40dBm level <=60 dBc yes * Sweep time @span >or= 1 KHz 0.1S to 1000 s * Sweep time @span = 0 Hz 100 micro S to 20 S * Resolution Bandwidth (-3dB) 10 Hz to 3 MHz in steps * Video Bandwidth 10Hz to 1 MHz in steps * Amplitude : Max input level for protection (dBm) +30 * Amplitude : Max input level for measurement (dBm) 20 * Amplitude :level measurement uncertainity (dB) <=2 * Average noise level dis played(@300HzRBW
10 Hz VBW) <=-110dBm for 10MHz to 3 GHz * Average noise level dis played(@100HzRBW
1 Hz VBW) <=-110dBm for 10MHz to 3 GHz * Average noise level dis played(@300HzRBW
1 Hz VBW) <=-110dBm for 10MHz to 3 GHz * Measurement features C/N ratio
AM%
time domain power measurement
channel power measurement
Phase noise measurement
TOI (THIRD ORDER INTERC EPT)
OBW(occupied bandwidth) * VECTOR NETWORK ANALYZER FEATURES Frequency Range for 2port vector network analyzer NA * Frequency Resolution NA * 2/6 (CW ON) (Hz) Return Loss (dB) NA * VSWR (dB) NA * Cable Loss (dB) NA * Calibration with Precision calibration components-open
short
load should be included to achieve directivity >35 dB NA * Abilty to locate Distance-to-fault in Co- axial cables NA * Phase Range (degree) NA * Phase Resolution (deg) NA * RF output port NA * Dynamic Range NA * Nominal port power output: Hi Power/Lo- Power selectable NA * Power levels corresponding to Hi and Lo levels NA * Measurement of S11 and S21 and Smith Chart NA * Vector Voltmeter for comparision and verification of the phase of the phase- matched cables NA * Group Delay measurement NA * OPERATING CONDITIONS Operating Temperature '5 to 40 degree C & 80% RH @ 40 degree C '5 to 40 degree C & 80% RH @ 40 degree C Operating Humidity 80% RH @ 40 degree C 80% RH @ 40 degree C POWER REQUIREMENT Power requirement 230 +- 10 VAC
50Hz
Rechargeable battery 230 +- 10 VAC
Rechargeable battery chemistry of the battery lithium ion * Voltage of rechargeable Battery 10.8 * capacity of rechargeable battery (millAh) 7500 * 3/6 Suitable charger adaptor provided Yes * WARRANTY Warranty 3 1
2
3
4
5 (or higher) ACCESSORIES Details of Standard accessories covered in the scope of supply 2000-1654-R Soft Carrying Case
2000-1691-R Stylus with Coiled Tether
2000-1797-R Screen Protector Film
8.4 inch (2
one installed)
633-75 Rechargeable Li- Ion Battery
40-187-R AC-DC Adapter
806-141-R Automotive Power Adapter
12 VDC
60 W
3-2000-1498 USB A/5-pin mini-B Cable
10 ft/305 cm * GENERIC Other features Features - Pre- Amplifier
Field Strength Measurement capability
AM/FM/SSB Analysis
6 dB EMI Bandwidth/QP Detection
VSWR
RL
DTF
Cable Loss
1-port Phase Measurement
Smith Chart Impedance measurement. Field- proven design Three- hour battery life
rugged
compact
lightweight
daylight viewable display. Intuitive menu-driven touchscreen user interface. Standard three-year warranty battery one-year warranty. Measurements Occupied Bandwidth
Channel Power
ACPR
C/I
Spectral Emission Mask. Dynamic Range 95 dB in 10 Hz RBW. DANL -152 dBm in 10 Hz RBW. Phase Noise -100 dBc/Hz max @ 10 kHz offset at 1 GHz. Save-on-Event. Cable and Antenna Analyzer 2 MHz 4 GHz. Return Loss
* 4/6 VSWR
Distance-To- Fault. Phase
2-port Transmission Measurements. 2000 Traces and setups can be stored internally. CERTIFICATION/TEST REPORT DETAILS The equipment supplied with calibration certificate yes * conformity to Dry Heat for 16 hrs at a specified maximum temp in accordance with IS:900 0/part-3/section-5/1977 latest no * conformity to Cold Test for 4 hrs at a specified minimum temp in accordance with IS:900 0/part-2/section-4/1977 latest no * conformity to Damp Heat (Cyclic)Test for 2 Cycles of 24 h each at a temp of 40 degree C & 95% RH no * Availability of Test Reports from Central Govt/NABL/ILAC approved accredited lab to prove conformity to the specification true * Test Report Number and date for the specification test - * Name and address of the Lab for the specification test - * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Bhikshapathy Kawati 500058
DRDL
KANCHANBAGH P.O. 2 30
559777
GEM/2018/B/79433
spectrum analyzers vector network analyzers
30 days
Telangana; Hyderabad
PRODUCT
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| Spectrum Analyzers Vector Network Analyzers ( 2 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values FEATURES Description of the itemuu Spectrum analyzers Spectrum analyzers GENERAL FEATURES COMMON TO SPECTRUM AND VECTOR ANALYSER Markers Normal | - | - | - |
| delta * Trigger Free run | - | - | - |
| video | - | - | - |
| External * Display TFT Colour display with provision for three traces * Interface USB * Software for transfer of screen shot/measurement data to PC Yes * SPECTRUM ANALYZER FEATURES Frequency Range 9 kHz to 3 GHz 9 kHz to 3 GHz Aging rate of spectrum analyzer frequency: Better than 1x10-6 Year Yes * Frequency counter 1 * 1/6 Resolution(minimum) (Hz) Frequency Span 100Hz to 3GHz * Spectral purity:SSB Phase Noise @10KHz offset shall be less than -90dBc/Hz at 1GHz Yes * Spectral purity:Harmonics @ -40dBm level <=60 dBc yes * Sweep time @span >or= 1 KHz 0.1S to 1000 s * Sweep time @span = 0 Hz 100 micro S to 20 S * Resolution Bandwidth (-3dB) 10 Hz to 3 MHz in steps * Video Bandwidth 10Hz to 1 MHz in steps * Amplitude : Max input level for protection (dBm) +30 * Amplitude : Max input level for measurement (dBm) 20 * Amplitude :level measurement uncertainity (dB) <=2 * Average noise level dis played(@300HzRBW | - | - | - |
| 10 Hz VBW) <=-110dBm for 10MHz to 3 GHz * Average noise level dis played(@100HzRBW | - | - | - |
| 1 Hz VBW) <=-110dBm for 10MHz to 3 GHz * Average noise level dis played(@300HzRBW | - | - | - |
| 1 Hz VBW) <=-110dBm for 10MHz to 3 GHz * Measurement features C/N ratio | - | - | - |
| AM% | - | - | - |
| time domain power measurement | - | - | - |
| channel power measurement | - | - | - |
| Phase noise measurement | - | - | - |
| TOI (THIRD ORDER INTERC EPT) | - | - | - |
| OBW(occupied bandwidth) * VECTOR NETWORK ANALYZER FEATURES Frequency Range for 2port vector network analyzer NA * Frequency Resolution NA * 2/6 (CW ON) (Hz) Return Loss (dB) NA * VSWR (dB) NA * Cable Loss (dB) NA * Calibration with Precision calibration components-open | - | - | - |
| short | - | - | - |
| load should be included to achieve directivity >35 dB NA * Abilty to locate Distance-to-fault in Co- axial cables NA * Phase Range (degree) NA * Phase Resolution (deg) NA * RF output port NA * Dynamic Range NA * Nominal port power output: Hi Power/Lo- Power selectable NA * Power levels corresponding to Hi and Lo levels NA * Measurement of S11 and S21 and Smith Chart NA * Vector Voltmeter for comparision and verification of the phase of the phase- matched cables NA * Group Delay measurement NA * OPERATING CONDITIONS Operating Temperature '5 to 40 degree C & 80% RH @ 40 degree C '5 to 40 degree C & 80% RH @ 40 degree C Operating Humidity 80% RH @ 40 degree C 80% RH @ 40 degree C POWER REQUIREMENT Power requirement 230 +- 10 VAC | - | - | - |
| 50Hz | - | - | - |
| Rechargeable battery 230 +- 10 VAC | - | - | - |
| Rechargeable battery chemistry of the battery lithium ion * Voltage of rechargeable Battery 10.8 * capacity of rechargeable battery (millAh) 7500 * 3/6 Suitable charger adaptor provided Yes * WARRANTY Warranty 3 1 | - | - | - |
| 2 | - | - | - |
| 3 | - | - | - |
| 4 | - | - | - |
| 5 (or higher) ACCESSORIES Details of Standard accessories covered in the scope of supply 2000-1654-R Soft Carrying Case | - | - | - |
| 2000-1691-R Stylus with Coiled Tether | - | - | - |
| 2000-1797-R Screen Protector Film | - | - | - |
| 8.4 inch (2 | - | - | - |
| one installed) | - | - | - |
| 633-75 Rechargeable Li- Ion Battery | - | - | - |
| 40-187-R AC-DC Adapter | - | - | - |
| 806-141-R Automotive Power Adapter | - | - | - |
| 12 VDC | - | - | - |
| 60 W | - | - | - |
| 3-2000-1498 USB A/5-pin mini-B Cable | - | - | - |
| 10 ft/305 cm * GENERIC Other features Features - Pre- Amplifier | - | - | - |
| Field Strength Measurement capability | - | - | - |
| AM/FM/SSB Analysis | - | - | - |
| 6 dB EMI Bandwidth/QP Detection | - | - | - |
| VSWR | - | - | - |
| RL | - | - | - |
| DTF | - | - | - |
| Cable Loss | - | - | - |
| 1-port Phase Measurement | - | - | - |
| Smith Chart Impedance measurement. Field- proven design Three- hour battery life | - | - | - |
| rugged | - | - | - |
| compact | - | - | - |
| lightweight | - | - | - |
| daylight viewable display. Intuitive menu-driven touchscreen user interface. Standard three-year warranty battery one-year warranty. Measurements Occupied Bandwidth | - | - | - |
| Channel Power | - | - | - |
| ACPR | - | - | - |
| C/I | - | - | - |
| Spectral Emission Mask. Dynamic Range 95 dB in 10 Hz RBW. DANL -152 dBm in 10 Hz RBW. Phase Noise -100 dBc/Hz max @ 10 kHz offset at 1 GHz. Save-on-Event. Cable and Antenna Analyzer 2 MHz 4 GHz. Return Loss | - | - | - |
| * 4/6 VSWR | - | - | - |
| Distance-To- Fault. Phase | - | - | - |
| 2-port Transmission Measurements. 2000 Traces and setups can be stored internally. CERTIFICATION/TEST REPORT DETAILS The equipment supplied with calibration certificate yes * conformity to Dry Heat for 16 hrs at a specified maximum temp in accordance with IS:900 0/part-3/section-5/1977 latest no * conformity to Cold Test for 4 hrs at a specified minimum temp in accordance with IS:900 0/part-2/section-4/1977 latest no * conformity to Damp Heat (Cyclic)Test for 2 Cycles of 24 h each at a temp of 40 degree C & 95% RH no * Availability of Test Reports from Central Govt/NABL/ILAC approved accredited lab to prove conformity to the specification true * Test Report Number and date for the specification test - * Name and address of the Lab for the specification test - * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Bhikshapathy Kawati 500058 | - | - | - |
| DRDL | - | - | - |
| KANCHANBAGH P.O. 2 30 | - | - | - |
Exempted
19 Sept 2018
26 Sept 2018
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_559777.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .