Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹47.2 LAccepted-AOC | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹51.2 L+₹3.3 L (6.86%)Rejected-Finance | L2 | Rejected-Finance BEING NOT L1 |
| Sl No | Description | Qty | Unit | SONA LAKSHMI ASSOCIATE L2 | SI ENTERPRISES L1 |
|---|---|---|---|---|---|
| 1.00 | Disconnecting existing electrical circuit carefully without any damage from indoor panel which is installed at inside of hanger and taking out outside manually any size of panel and shifting/connecting all circuit, three pahase electric meter to new panels with require necessary T&P and labor complete all as directed by Engr-in-Charge. | 15 | Each | 99 ₹1,485 Lowest | 5,000 ₹75,000 |
| 2.00 | Supply and laying,testing & commissioning fitted on wall, plinth, with saddle coupling with drilling oe exisiting wall for passing LT XLPE insulated/PVC heavy duty armoured cablle 1100 volts grade UG multi-stranded aluminium conductor electric cable cross sectional area 35 Sqmm 3.5 Core including necessary connection with provision of lugs & cable gland fixing arrangements , compete all as specified and directed by Eng- In Charge | 150 | RM | 200 ₹30,000 Lowest | 480 ₹72,000 |
| 3.00 | All as per item No 2 but size of LT XLPE cable 50 Sqmm 3.5 Core including complete all as specified and directed. | 300 | RM | 260 ₹78,000 Lowest | 675 ₹2,02,500 |
| 4.00 | All as per item No 2 but size of LT XLPE 16 Sqmm 4 Core including complete all as specified and directed. | 300 | RM | 150 ₹45,000 Lowest | 300 ₹90,000 |
| 5.00 | All as per item No 2 but size of LT XLPE 95 Sqmm 3.5 Core including complete all as specified and directed. | 350 | RM | 500 ₹1,75,000 Lowest | 1,100 ₹3,85,000 |
| 6.00 | All as per item No 2 but size of LT XLPE 25 Sqmm 3.5 Core including complete all as specified and directed. | 150 | RM | 180 ₹27,000 Lowest | 500 ₹75,000 |
| 7.00 | Excavation in trenches n. exc 1.5 Mtr wide and n. exc 1.5 mtr in depth and getting out in soft soil. | 22 | Cum | 200 ₹4,400 Lowest | 500 ₹11,000 |
| 8.00 | Excavation in trenches n. exc 1.5 Mtr wide and n. exc 1.5 mtr in depth and getting out in hard soil, compete all as specified and directed by Eng- In Charge. | 33.75 | Cum | 250 ₹8,437.5 Lowest | 500 ₹16,875 |
| 9.00 | Returning Filling in including spreading, leveling, watering & well ramming in layers n. exc 25 Cm, compete all as specified and directed by Eng- In Charge | 32.75 | Cum | 40 ₹1,310 Lowest | 200 ₹6,550 |
| 10.00 | Removing excavated/Surplus soil n exc 50 Mtr & depositing where directed at a level n. exc 1.5 Mtr above the starting point, compete all as specified and directed by Eng- In Charge | 1 | Cum | 40.01 ₹40.01 Lowest | 200 ₹200 |
Tender Value
₹43 L
EMD Value
₹86,000
Closing Date
1 May 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF OJHAR
GE AF OJHAR
AUGMENTATION OF LT NETWORK FOR RELOCATION OF ELECTRIC PANEL OFOTSIDE OF HANGER AND ALLIED WORKS AT AF STN DEVLALI.
2025_MES_702989_1
8277/E8
Open Tender
Electrical and Maintenance Works
Item Rate
240 days
DEVLALI
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE AF OJHAR
₹86,000
Yes
13 Oct 2025
28 Mar 2025
3 May 2025
29 Mar 2025
1 May 2025
12 Apr 2025
Amount
Disconnecting existing electrical circuit carefully without any damage from indoor panel which is installed at inside of hanger and taking out outside manually any size of panel and shifting/connecting all circuit, three pahase electric meter to new panels with require necessary T&P and labor complete all as directed by Engr-in-Charge.
Supply and laying,testing & commissioning fitted on wall, plinth, with saddle coupling with drilling oe exisiting wall for passing LT XLPE insulated/PVC heavy duty armoured cablle 1100 volts grade UG multi-stranded aluminium conductor electric cable cross sectional area 35 Sqmm 3.5 Core including necessary connection with provision of lugs & cable gland fixing arrangements , compete all as specified and directed by Eng- In Charge
All as per item No 2 but size of LT XLPE cable 50 Sqmm 3.5 Core including complete all as specified and directed.
All as per item No 2 but size of LT XLPE 16 Sqmm 4 Core including complete all as specified and directed.
All as per item No 2 but size of LT XLPE 95 Sqmm 3.5 Core including complete all as specified and directed.
All as per item No 2 but size of LT XLPE 25 Sqmm 3.5 Core including complete all as specified and directed.
Excavation in trenches n. exc 1.5 Mtr wide and n. exc 1.5 mtr in depth and getting out in soft soil.
Excavation in trenches n. exc 1.5 Mtr wide and n. exc 1.5 mtr in depth and getting out in hard soil, compete all as specified and directed by Eng- In Charge.
Returning Filling in including spreading, leveling, watering & well ramming in layers n. exc 25 Cm, compete all as specified and directed by Eng- In Charge
Removing excavated/Surplus soil n exc 50 Mtr & depositing where directed at a level n. exc 1.5 Mtr above the starting point, compete all as specified and directed by Eng- In Charge
M&L for double wall corrugated (DWC) duct (dure guard) as per IS 14930 part II LT UG cable protection including coupler, elbows, T joiints, Bends etc. and test report Make: Dura line/ Gemini/ Tele-Rex of size 63 mm outer dia , compete all as specified and directed by Eng- In Charge
M&L for double wall corrugated (DWC) duct (dure guard) as per IS 14930 part II LT UG cable protection including coupler, elbows, T joiints, Bends etc. and test report Make: Dura line/ Gemini/ Tele-Rex of size dia 80 mm outer dia , compete all as specified and directed by Eng- In Charge
M&L for Cable route indicator fabricated construct-ed/fabricated on 600x180x40mm Precast RCC/PCC , duly painted with yellow colour synthetic enamel paint complete marking name on MS round disc silver painted duly rein--forced in PCC precast route indicator with nomenclature of "/LT cable size in Sq mm/LT cable Joint" in letters with suitable visible font including grouted in ground with PCC 1:4:8 type D-2, compete all as specified and directed by Eng- In Charge
Material & Labour for Boring of holes under existing road, pavement, hard standing not less than 0.7 Meter below GL by trenchless technology using ultra sound technique and necessary machine by doing excavation at both side of and passing the seamless 150 mm dia , 0.4 mpa working pres-sure HDPE pipe by bringing complete set up at site , compete all as specified and directed by Eng- In Charge
M & L for cement concrete (1:3:6 ) type C-1 using 20 mm graded stone aggregate, including weathering, slightly rounded Chamfered angles and throating including for erthing pit, errection of GI tube light grade as in foundation in any size necessary form work, compete all as specified and directed by Eng- In Charge
M&L of Tubes, 'medium grad', galvanised, with all fitting Tee elbow, socket etc laid in trenches, compete all as specified and directed by Eng- In Charge
M&L, T&P for cutting of existing PCC/PQC/foundation road, path for laying of GI pipe for cable protection complete all as specified and directed by Engr in Charge.
M&L for earthing complete with galvanised steel earth plate electrode 600x600x6 mm thick, burried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to GI strip 25x4 mm through GI pipe 40 mm dia light grade by means of bolts,nuts, check nuts and washers of galvanised iron or steel,with adequate quantity of charcoal and salt, proper watering arrangements including 20 mm dia medium grade GI tubing.PCC chamber,Chamber Cover all as shown in electrical plate no 3 of SSR part I 2009 connected to earthing test point all as specified or indicated and testing on completion. The end point connection of eatrhing will be carried out with the help of GI bolt grouted and washer and nut , compete all as specified and directed by Eng- In Charge
Supply, install, testing and commissioning of IP 65 cubicle type outdoor LT distribution panel fabricated out of 3.15mm thick of size CRCA sheet with separate locking arrangement, painted with epoxy powder coated over a coat of red oxide primer, factory made, cubical type, double door hinged type, both side openable, holes for cable entries, detachable gland plates at top and bottom, earth connection terminals etc. and mounted on 50x50x6 mm or higher size zinc passivated angle iron frame hight form ground level 600 mm, adebquete clearence from ground level for the entry and exit of cable, provision of ventilation on sides, manufacturer details, necessary PCC around panel 2x2 mtr, work for grouting and provn of cable lugs for connection CPRI approved of Panel Size shall not be less than (950x1400X500) mm with c with earth leakage plus shunt coil and trip alaram contact complete and consisting of following , compete all as specified and directed by Eng- In Charge Incoming (a) MCCB 4 pole 160 Amp,25 KA microprocessor based Cat No 420317 Qty -01 Nos (b) Indication lamps 03 RYB (c) Copper Bus Bar of size 1.5 times Ampere rating of that incommer breaker, 415 volt, 4 pole TPN, colour coded with PVC/epoxy insulation & mounted on insulators (d) ROM Directed- 01 Nos Out going (a) MCB 4 pole 32 Amp,10 KA Cat part No 408680 out going- 08 Nos (b) Provision of refixing existing three phase energy meter -01 Nos (c) Multifuction panel meter square type to measure three/single Voltage phase, load current, frequency, power factor kWh including necessary CT/PT of suitable ratio (WL4110100000) -01 Nos (d) Earth leakage + shunt coil + TAC -01 Nos
Note (For Sl No 19 to 29 )-1. The cost of the PCC plinth /foundation deemed to be included in the quoted rate of the above said item. The pannel shall be comprising the following items 2.ALL MCCB should be operated by veri depth extendable rotary handle. 3.Bus bar directly connected to incomer of outgoing MCCB,s ,not by PVC flexible wires. 4.Proper air ventilation in case of IP43 Protection. 5.Every MCCB has separate compartment. 6.V curve ( upper portion)50 mm outside from both side 7.Panel should be operated from front side only(dead Rear side) 8.Neoprene gasket at doors & bakelite plate/rubeer spacers for insulation /separation 9.Outdoor panel sheet thickness 3.15 mm and internal size shall be 1.5 mm thick & indoor panel sheet thickness 2 mm unless otherwise specified. 10.Panel handle should be rubber grip insulated or polycarbonate handle( panel should Not opened by Nude steel handle ) 11. All cables (incoming and outgoing) should pass through bottom gland plate with proper size of gland for protection of lizard,snake etc 12.Cable connection by MCCB's should be by proper lugs and lugs pressed by proper tools . Bimetallic lugs use in case of copper bus bar. 13.Line diagram stick on inner side of door ( coloured paper sheet and laminated) 14.Every compartment has permanent nomeclature plate,made of steel,riveted joint( not sticker) like( Example-MCCB,160Amps,4P,36KA) 15.Danger notice plate ,made of steel,riveted joint (not sticker) 16.Name plate,made of steel ( Manufacturer name,Year of manufacturing,IP -65) 17. Copper Bus Bar of size 1.5 times Amp rating of that incommer breaker, 415 volt, 4 pole TPN, colour coded with PVC/epoxy insulation & mounted on insulators. 18. All Cat No is mentioned as Legrand switch Gear or equivalent Siemens , ABB,Havells, Panel drawing shall be approved by accepting officer and shall conforming to IS : 60947 :(Latest ammended).
Supply, install, testing and commissioning of IP 65 cubicle type outdoor LT distribution panel fabricated out of 3.15mm thick of size CRCA sheet with separate locking arrangement, painted with epoxy powder coated over a coat of red oxide primer, factory made, cubical type, double door hinged type, both side openable, holes for cable entries, detachable gland plates at top and bottom, earth connection terminals etc. and mounted on 50x50x6 mm size zinc passivated angle iron frame hight form ground level 600 mm, adebquete clearence from ground level for the entry and exit of cable, provision of ventilation on sides, manufacturer details, necessary PCC around panel 2x2 mtr, work for grouting and provn of cable lugs for connection CPRI approved of size shall not be less than (950mm Hight, 1400 mm width & 500mm depth) with earth leakage plus shunt coil and trip alaram contact complete and consisting of following all as specified and directed by Engr-in-Charge. Incoming (a) MCCB 4 pole 160 Amp,25 KA microprocessor based Cat part No 420317 Qty -01 Nos (c) Indication lamps 03 RYB (d) Copper Bus Bar of size 1.5 times Ampere rating of that incommer breaker, 415 volt, 4 pole TPN, colour coded with PVC/epoxy insulation & mounted on insulators (e) ROM Directed- 01 Nos Out going (a) MCB 4 pole 32 Amp,10 KA Cat No 408680 out going- 12 Nos (b) MCCB 4 pole 40 Amp, microprocessar cat No 420312 - 02 Nos (c) Multifuction panel meter square type to measure three/single Voltage phase, load current, frequency, power factor kWh including necessary CT/PT of suitable ratio. (WL4110100000) -01 Nos (d) Earth leakage + shunt coil + TAC -01 Nos
Supply, install, testing and commissioning of IP 65 cubicle type outdoor LT distribution panel fabricated out of 3.15mm thick of size CRCA sheet with separate locking arrangement, painted with epoxy powder coated over a coat of red oxide primer, factory made, cubical type, double door hinged type, both side openable, holes for cable entries, detachable gland plates at top and bottom, earth connection terminals etc. and mounted on 50x50x6 mm or higher size zinc passivated angle iron frame hight form ground level 600 mm, adebquete clearence from ground level for the entry and exit of cable, provision of ventilation on sides, manufacturer details, necessary PCC around panel 2x2 mtr, work for grouting and provn of cable lugs for connection CPRI approved of size shall not be less than (2150mm Hight, 1100 mm width & 1100mm depth) with earth leakage plus shunt coil and trip alaram contact complete and consisting of following all as specified and directed by Engr-in-Charge. Incoming (a) ACB 1000A 4P 50 KA MDO microprocessar Cat part No 028732 -01 Nos (b) MCCB 4 pole 250 Amp, 4P 36 KA microprocessor cat part No 420349 - 01 Nos ( c) Copper Bus Bar of size 1.5 times Ampere rating of that incommer breaker, 415 volt, 4 pole TPN, colour coded with PVC/epoxy insulation & mounted on insulators OUTGOING (c) MCCB 4 pole 160 Amp, 4P 25 KA microprocessar Cat part No 420317 - 01 Nos (d) MCCB 4 pole 100 Amp, 4P 25 KA microprocessar Cat part No 420315 - 05 Nos (e) Indication lamps 03 RYB (g) Extended Rotary Handle -07 Nos (h) Provision of refixing existing three phase energy meter -01 Nos (j) Multifuction panel meter square type to measure three/single Voltage phase, load current, frequency, power factor kWh including necessary CT/PT of suitable ratio. (WL4110100000)-01 Nos (k) Earth leakage + shunt coil + TAC -01 Nos
Supply, install, testing and commissioning of IP 65 cubicle type outdoor LT distribution panel fabricated out of 3.15mm thick of size CRCA sheet with separate locking arrangement, painted with epoxy powder coated over a coat of red oxide primer, factory made, cubical type, double door hinged type, both side openable, holes for cable entries, detachable gland plates at top and bottom, earth connection terminals etc. and mounted on 50x50x6 mm or higher size zinc passivated angle iron frame hight form ground level 600 mm, adebquete clearence from ground level for the entry and exit of cable, provision of ventilation on sides, manufacturer details, necessary PCC around panel 2x2 mtr, work for grouting and provn of cable lugs for connection CPRI approved of size (2150mm Hight, 1100 mm width & 1100mm depth) with earth leakage plus shunt coil and trip alaram contact complete and consisting of following all as specified and directed by Engr-in-Charge. INCOMMING (a) ACB 1000A 4P 50 KA MDO microprocessar Cat part No 028732 -01 Nos (b) Copper Bus Bar of size 1.5 times Ampere rating of that incommer breaker, 415 volt, 4 pole TPN, colour coded with PVC/epoxy insulation & mounted on insulators OUTGOING (c) MCCB 4 pole 400 Amp, 4P 36KA microprocessar Cat part No 422063 - 02 Nos (d) MCCB 4 pole 160 Amp, 4P 25KA microprocessar Cat part No 420317 - 01 Nos (e) MCCB 4 pole 250 Amp, 4P 36KA microprocessar Cat part No 420349 - 01 Nos (f) Indication lamps 03 RYB (g) Extended Rotary Handle -04 Nos (j) Provision of refixing existing three phase energy meter -01 Nos (k) Multifuction panel meter square type to measure three/single Voltage phase, load current, frequency, power factor kWh including necessary CT/PT of suitable ratio. (WL4110100000)-01 Nos (l) Earth leakage + shunt coil + TAC -01 Nos
Supply, install, testing and commissioning of IP 65 cubicle type outdoor LT distribution panel fabricated out of 3.15mm thick of size CRCA sheet with separate locking arrangement, painted with epoxy powder coated over a coat of red oxide primer, factory made, cubical type, double door hinged type, both side openable, holes for cable entries, detachable gland plates at top and bottom, earth connection terminals etc. and mounted on 50x50x6 mm size zinc passivated angle iron frame hight form ground level 600 mm, adebquete clearence from ground level for the entry and exit of cable, provision of ventilation on sides, manufacturer details, necessary PCC around panel 2x2 mtr, work for grouting and provn of cable lugs for connection CPRI approved of size shall not be less than (800mm Hight, 1400 mm width & 500mm depth) with earth leakage plus shunt coil and trip alaram contact complete and consisting of following all as specified and directed by Engr-in-Charge. Incoming (a) MCCB 4 pole 100 Amp, 4P 25KA microprocessar Cat part No 420315 - 01 Nos (b) Copper Bus Bar of size 1.5 times Amp rating of that incommer breaker, 415 volt, 4 pole TPN, colour coded with PVC/epoxy insulation & mounted on insulators Out Going (c) MCB 4 pole 32 Amp,10 KA Cat part No 408680 out going- 03 Nos (d) Provision of refixing existing three phase energy meter -01 Nos (e) Multifuction panel meter square type to measure three/single Voltage phase, load current, frequency, power factor kWh including necessary CT/PT of suitable ratio. (WL4110100000)-01 Nos (f) Earth leakage + shunt coil + TAC -01 Nos
Supply, install, testing and commissioning of IP 65 cubicle type outdoor LT distribution panel fabricated out of 3.15mm thick of size CRCA sheet with separate locking arrangement, painted with epoxy powder coated over a coat of read oxide primer, factory made, cubical type, double door hinged type, both side openable, holes for cable entries, detachable gland plates at top and bottom, earth connection terminals etc. and mounted on 50x50x6 mm or highr size zinc passivated angle iron frame hight form ground level 600 mm, adebquete clearence from ground level for the entry and exit of cable, provision of ventilation on sides, manufacturer details, necessary PCC around panel 2x2 mtr, work for grouting and provn of cable lugs for connection CPRI approved of size shall not be less than (1000mm Hight, 1500 mm width & 500mm depth) with earth leakage plus shunt coil and trip alaram contact complete and consisting of following all as specified and directed by Engr-in-Charge. Incoming (a) MCCB 4 pole 100 Amp, 4P 25KA microprocessar Cat part No 420315 - 01 Nos (b) Copper Bus Bar of size 1.5 times Ampere rating of that incommer breaker, 415 volt, 4 pole TPN, colour coded with PVC/epoxy insulation & mounted on insulators Out Going (a) MCCB 4 pole 40 Amp,16 KA microprocessar Cat part No 420312- 08 Nos (b) Provision of refixing existing three phase energy meter -01 Nos (c) Multifuction panel meter square type to measure three/single Voltage phase, load current, frequency, power factor kWh including necessary CT/PT of suitable ratio. (WL4110100000)-01 Nos (d) Earth leakage + shunt coil + TAC- 01 Nos (e) Extended Rotary Handle -09 Nos
Supply, install, testing and commissioning of IP 65 cubicle type 300 Amp mini-pillar box with copper bus bar of size (30x10mm) fabricated out of 3.15mm thick CRCA sheet of size not less than 500mmx500mmx250mm with MS angle iron of size not less than 50x50x6 mm fitted on wall ground without damage existing wall repair surface as match with existing surface with PCC complete and heat shrinkable cable joint kit , straight through , out door type for 1100 volts LT XLPE/PVC insulated cable of aluminium conductor 25 sqmm to 95 sqmm 3/5 core cable including necessary jointing work if require site all as specified and directed by Engr-in-Charge.
Supply, install, testing and commissioning of IP 65 connector box cubicle type 40 Amp connector (Terminal provision 40 Amp) box with copper bus bar of size (20x10mm) fabricated out of 3.15mm thick CRCA sheet of size not less than 400mmx400mmx250mm with MS angle iron of size not less than 50x50x6 mm fitted on wall ground without damage existing wall repair surface as match with existing surface with PCC complete and heat shrinkable cable joint kit , straight through , out door type for 1100 volts LT XLPE/PVC insulated cable of aluminium conductor 25 sqmm to 95 sqmm 3/5 core cable including necessary jointing work if require site all as specified and directed by Engr-in-Charge.
Supply, install, testing and commissioning of IP 65 cubicle type outdoor LT distribution panel ELR fabricated out of 3.15mm thick of size CRCA sheet with separate locking arrangement, painted with epoxy powder coated over a coat rea oxide primer, factory made, cubical type, double door hinged type, both side openable, holes for cable entries, detachable gland plates at top and bottom, earth connection terminals etc. and mounted on 50x50x6 mm size zinc passivated angle iron frame hight form ground level 600 mm, adebquete clearence from ground level for the entry and exit of cable, provision of ventilation on sides, manufacturer details, necessary PCC around panel 1x1 mtr, work for grouting and provn of cable lugs for connection CPRI approved of size shall not be less than (1000mm Hight, 1500 mm width & 500mm depth) with earth leakage plus shunt coil and trip alaram contact complete and consisting of following all as specified and directed by Engr-in-Charge. Incoming (a) MCCB 4 pole 100 Amp, 4P 25KA microprocessar Cat part No 420315- 01 Nos (b) Copper Bus Bar of size 1.5 times Ampere rating of that incommer breaker, 415 volt, 4 pole TPN, colour coded with PVC/epoxy insulation & mounted on insulators Out Going (a) Provision of refixing existing three phase energy meter -01 Nos (b) Multifuction panel meter square type to measure three/single Voltage phase, load current, frequency, power factor kWh including necessary CT/PT of suitable ratio. (WL4110100000)-01 Nos (c) Earth leakage + shunt coil + TAC- 01 Nos (d) Extended Rotary Handle -01 Nos
Supply, install, testing and commissioning of IP 65 PDB cubicle type outdoor LT distribution panel fabricated out of 3.15mm thick CRCA sheet with separate locking arrangement, painted with epoxy powder coated over a coat rea oxide primer, factory made, cubical type, double door hinged type, both side openable, holes for cable entries, detachable gland plates at top and bottom, earth connection terminals etc. and mounted on 50x50x6 mm size zinc passivated angle iron frame hight form ground level 600 mm, adebquete clearence from ground level for the entry and exit of cable, provision of ventilation on sides, manufacturer details, necessary PCC around panel 1x1 mtr, work for grouting and provn of cable lugs for connection CPRI approved of size shall not be less than (1500 mm Hight, 1650 mm width & 500mm depth) with earth leakage plus shunt coil and trip alaram contact complete and consisting of following all as specified and directed by Engr-in-Charge. Incoming (a) MCCB 4 pole 250 Amp, 4P 36KA microprocessar Cat part No 420349 - 01 Nos (b) Copper Bus Bar of size 1.5 times Ampere rating of that incommer breaker, 415 volt, 4 pole TPN, colour coded with PVC/epoxy insulation & mounted on insulators Out Going (a) MCCB 4 pole 40 Amp, 4P 25KA microprocessar Cat part No 420312- 03 Nos (b) MCCB 4 pole 160Amp, 4P 25KA microprocessar Cat part No 420317 - 01 Nos (c) Provision of refixing existing three phase energy meter -01 Nos (d) Multifuction panel meter square type to measure three/single Voltage phase, load current, frequency, power factor kWh including necessary CT/PT of suitable ratio. (WL4110100000)-01 Nos (e) Earth leakage + shunt coil + TAC- 01 Nos (f) Extended Rotary Handle -05 Nos
Supply, install, testing and commissioning of IP 65 PDB cubicle type outdoor LT distribution panel fabricated out of 3.15mm thick CRCA sheet with separate locking arrangement, painted with epoxy powder coated over a coat rea oxide primer, factory made, cubical type, double door hinged type, both side openable, holes for cable entries, detachable gland plates at top and bottom, earth connection terminals etc. and mounted on 50x50x6 mm size zinc passivated angle iron frame hight form ground level 600 mm, adebquete clearence from ground level for the entry and exit of cable, provision of ventilation on sides, manufacturer details, necessary PCC around panel 1x1 mtr, work for grouting and provn of cable lugs for connection CPRI approved of size shall not be less than (1500 mm Hight, 1650 mm width & 500mm depth) with earth leakage plus shunt coil and trip alaram contact complete and consisting of following all as specified and directed by Engr-in-Charge. Incoming (a) MCCB 4 pole 250 Amp, 4P 36KA microprocessar Cat part No 420349 - 01 Nos (b) Copper Bus Bar of size 1.5 times Ampere rating of that incommer breaker, 415 volt, 4 pole TPN, colour coded with PVC/epoxy insulation & mounted on insulators Out Going (a) MCCB 4 pole 40 Amp, 4P 16KA microprocessar Cat part No 420312 - 03 Nos (b) MCCB 4 pole 160Amp, 4P 25KA microprocessar Cat part No 420317 - 01 Nos (c) Provision of refixing existing three phase energy meter -01 Nos (d) Multifuction panel meter square type to measure three/single Voltage phase, load current, frequency, power factor kWh including necessary CT/PT of suitable ratio. (WL4110100000)-01 Nos (e) Earth leakage + shunt coil + TAC- 01 Nos (f) Extended Rotary Handle -05 Nos
SONA LAKSHMI ASSOCIATE (BID ID -3284442)
stage.html
html • 0.04 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .