Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.5 LAccepted-AOC GORAKHPUR UTTAR PRADESH | GORAKHPUR | GORAKHPUR | UTTAR PRADESH | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹36.1 L+₹2.6 L (7.84%)Rejected-Finance | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹36.4 L+₹2.9 L (8.67%)Rejected-Finance | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹37.9 L+₹4.4 L (13.1%)Rejected-Finance H NO 273 VPO SURHERA WEST DELHI 110043 | WEST DELHI | DELHI | 110043 | L4 | Rejected-Finance Other than L1 |
Tender Value
₹35.8 L
EMD Value
₹71,600
Closing Date
19 Feb 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Faridkot
Garrison Engineer, Faridkot-151203 Punjab 01639-264982
Provn of 12 x Elevated Sentry Posts at certain locations at Faridkot Mil Stn
2022_MES_503143_1
GE FRD-71/2021-22
Open Tender
Civil Works
Item Rate
180 days
Faridkot
Class D category a i
8 documents required · 8 mandatory
₹500
Yes
GE Faridkot
₹71,600
Yes
3 Mar 2022
22 Jan 2022
21 Feb 2022
22 Jan 2022
19 Feb 2022
5 Feb 2022
60 days
Amount
Excavation in trenches in any type of soil not exceeding 1.5m deep and 1.5m wide, for foundation etc or manholes,piers,shafts etc not exceeding 10 Sqm on plan and getting out complete all as specified and directed.
M&L for cement concrete 1:4:8 type D-2 (using 40mm graded crushed stone aggregates) as in foundation, filling & mass concrete complete all as specified and directed .
M & L for Reinforced Cement Concrete M-25 (Design Mix) (using 20 mm graded crushed stone aggregates) as in foundation including rafts, footings, foundation beams, plinth beams, bases of columns etc complete all as specified and directed
M &L for Reinforced Cement Concrete M-25 (Design Mix) (using 20 mm graded crushed stone aggregates) as in beams, cantilever, lintels over 1.5 m,lintel bands etc complete all as specified and directed.
M &L for Reinforced Cement Concrete M-25 (Design Mix) (using 20 mm graded crushed stone aggregates) as in Columns, pillars, piers, posts and struts complete all as specified and directed.
M &L for Reinforced Cement Concrete M-25 (Design Mix) ( using 20 mm graded crushed stone aggregates) as in slabs supported on walls, beams and columns in floor, roof, landing, balconies, conopies, decks slab and in shelves and like complete all as specified and directed.
M&L for form work to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams and similar work; vertical or to batter, for rough finished surfaces of concrete all as specified and directed.
M&L for use and waste of formwork to sides and soffits of beams, lintels with chajja over 1.5m clear span and like complete all as specified and directed.
M&L for use and waste of form work to sides of columns square/rectangular for fair finished surfaces complete all as specified and directed.
M&L for use and waste of form work to soffits of suspended slab such as roof slabs, not exceeding 200mm thick, horizontal or sloping complete all as specified and directed .
M&L for use and waste of form work to edges of concrete flats, treads, window Cills, etc, exceeding 10cm but not exceeding 20cm wide complete all as specified and directed .
M&L for Mild steel TMT bars 10mm dia and over, cut to length, bent to shape as required, including cranking, bending and binding with & including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed .
M&L for Mild steel TMT bars 5 mm dia and over upto & including 10mm dia, as in stirrups, spacers and binders,cut to length bent to shape required including cranking, binding spirally for hooping for columns, hooking ends and binding with and including MS wire annealed not less than 0.9 mm dia or securining with clip complete all as specified and directed .
M&L for brick work with fly ash bricks using old size bricks, straight or curved on plan exceeding 6m mean radius, built in cement mortar 1:6 complete all as specified and directed .
M&L for Framed work as in doors or gates,ladders,cooler stands etc of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing using Fe 290 (Gde-E-165) complete. complete all as specified and directed .
M&L for Mild steel, plain, black sheet 1.25 mm thick in covering to door shutters, steel gates and similar work, cut to size,edges beaded if directed, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc.as required complete all as specified and directed .
M&L PCC 1:3:6 type C-0 (using 12.5mm graded crushed stone aggregates) as in bed blocks,fixing of hold fasts and similar works including necessary formwork complete all as specified and directed.
S&F 100mm mild steel butt hinges, medium weight,cold rolled complete all as specified and directed.
S&F Mild steel pressed handle of size 150mm, oval type, stove enamelled black complete all as specified and directed.
S&F Mild steel barrel tower bolts of length 200mm, stove enamelled black, with bright bolt complete all as specified and directed .
M&L for Mild steel sliding door bolts of length 250mm, plate type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate complete all as specified and directed
S&F factory made box type steel windows with side hung shutters including projecting type hinges with steel handles, tower bolts and steel peg stay, complete with glazing bars, dovetailed or welded all as specified and directed
S&F factory made box type steel windows with side hung shutters including projecting type hinges with steel handles, tower bolts and steel peg stay, complete without glazing bars, dovetailed or welded all as specified and directed
M&L for 3 mm thick, plain sheet glass, ordinary quality and glazing with oil putty or with wooden beads in squares n.exc 0.5 sqm each pane complete all as specified and directed .
S&F galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture not more than 1.18mm and fixed with tinned tacks or galvanised wire staples complete all as specified and directed .
Returning, filling in, including spreading, leveling watering and well ramming in layers not exceeding. 25cm thick complete all as specified and directed .110
Removal of surplus soil to a distance not exceeding. 50 m & depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed .
M&L for Earth filling under floors etc in layers n.exc 25 cm thick complete all as specified and directed.
M&L for hard core of gauge not exceeding 63mm using broken stone or boulders, deposited, spread and leveled in layers not exc 15cm thick, watered and rolled/rammed to a true surfaces complete all as specified and directed
M&L for 10mm thick rendering in cement mortar 1:4 as concrete surfaces in roof, finished even and fair complete all as specified and directed .
M&L for applying evenly a tack coat of industrial bitumen 85/25 at the rate of 1.2 kg per sq.m including cleaning surfaces complete all as specified and directed . .
M&L for APP based polymeric membrane, minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) land on primed surface by forced application including two coats of aluminium paint over APP membrane complete all as specified and directed .
M&L for 75mm thick plain cement concrete 1:4:8 type D-2 (using 40mm graded crushed stone aggregates) as in sub base complete all as specified and directed .
M&L for 15mm thick rendering in cement mortar 1:4 on fair faces of brick work or concrete surfaces, finished even and smooth without using extra cement complete all as specified complete all as specified and directed.
M&L for 15mm thick rendering in cement mortar 1:6 on other than fair faces of brick work or on one side lathing, finished even and smooth without using extra cement complete all as specified complete all as specified and directed.
M & L for preparation of newly plastered or unplastered wall surfaces and applying two coats of cement base paint over one coat of primer complete all as specified and directed
M&L for preparation of new plastered or unplastered surfaces of walls and applying two coats of white wash complete all as specified and directed.
M&L for rendering 10 mm thick in cement mortar 1:3 on ceiling, surface finished even and smooth without using extra cement complete all as specified and directed.
M&L for polythene film, 50 micron thick, laid in floor conforming to IS specification complete all as specified and directed
S&F Machine cut kota stone slab in flooring 20-25mm thick laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing,cutting and mirror polishing over and including 15 mm thick screed bed or bedding layer in cement mortar 1:4 complete all as specified and directed.
S&F Machine cut kota stone slab 20-25 mm thick as in verical surfaces such as skirting ,dado, pillars and like , set and jointed in cement slurry and pointed in cement mixed with pigment to match the shade of slab including rubbing, cutting and mirror type polishing complete all as specified and directed .
M&L for preparation of new plastered or unplastered surfaces of ceiling and applying two coats of white wash complete all as specified and directed
M&L for preparation of new or previously untreated steel surface of any description over 10cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed
Surface excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out in any type of soil complete all as specified and directed
M&L Sand filling under floors etc in layers n.exc 25 mm thick complete all as specified and directed.
M&L machine pressed, precast concrete interlocking coloured paver block, any shape and size confirming to IS-15658-2006 of 60mm thickness, M-35 Grade with grey cement and pigment complete all as specified and directed.
S&F factory made precast kerb stones in PCC 1:2 :4 type B-1 including chamfers, weatherings,throatings etc in smooth finish & set in cement mortar 1:4 including necessary excavtion and earth work for embedding kerb stone at a depth as directed and temping around kerb stone and removal of surplus soil to a distance not exceeding 50 m and depositing where directed complete all as specified and directed .
M&L for preparation of new plastered /concrete surface and painting with two coats of synthetic enamel paint (white/golden yellow) over a coat of primer complete all as specified and directed
M&L PCC 1:3:6 type C1 (using 20mm graded crushed stone aggregates) in coping,back of kerb stone, rounded or chamfered on edges, slightly rounded or chamfered angles and throating, and necessary formwork (in sides of path/paving) complete all as specified and directed
Point wiring complete with 1.5 sqmm single core PVC insulated unsheathed cable(ISI marked) 1100 volts grade FRLS with multistranded copper conductor, drawn through concealed / surface in wall / roof/ceiling surface and its accessories on the surface etc including PVC rigid concealed conduit of suitable size with all accessories such as bend, reducers, MS hooks, MS junction boxes, 2mm thick galvanised steel pressed sunken terminal boxes of suitable sizes for mounting of switches, sockets, fan regulator etc, covered with 2.8mm thick plastic laminate Hylem / Anchor top cover sheet of required colour, fixed with brass screws and cup washers, painting terminal boxes inside and outside with one coat of red oxide primer including continuous earth wire of size 1.5 Sqmm PVC stranded copper conductor unsheathed, insulated, stranded (Green colour) connected to common earth point dolly for One light point/ fan point/ exhaust fan point and call bell point to be controlled by one number one way switch complete all as specified and directed .
All as per Srl item No. 50 here-in-before but for one 5 pin socket outlet 5 Amps on same board with other switches.
All as per Srl item No. 50 here-in-before but for switch socket combination (multi purpose) 5 Pin 5 Amps 230 volts on independent board.
All as per Srl item No. 50 here-in-before for switch socket combination (multi purpose) 6 Pin 15 Amps 230 volts point to be controlled by one switch and wiring with 2.5 Sqmm FRLS PVC unsheathed copper conductor and FRLS cable 2.5 Sqmm PVC insulated earth wire on independent board.complete all as specified and directed .
S&F PVC Lamp holder with back plate suitable for batten fittings complete all as specified and directed .
S&F LED bulb 1x10 watt having luminous efficiency warranty 2 years complete all as specified and directed .
S&F complete set of tube light fitting, 1x20 watt LED (4 feet long) 230 volt, decorative ultra slim linear LED lighting fixture with environment friendly, energy efficient ready to use pack etc with all acessories such as LED adopter, LED tube, internally prewired and including connecting up with twin core twisted flexible copper conductor cable of suitable size complete all as specified and directed
S&F ceiling rose, three terminals, PVC polycarbonate, isolated body with bakalite 20mm back plate complete all as specified and directed .
S&F switch piano type, single pole, one way, 5 Amp, 230 Volt AC supply complete all as specified and directed .
S&F socket two in one, 5 Pin 5 Amps 230 Volt AC supply, complete all as specified and directed .
S&F switch piano, flush type, single pole, one way, 15 Amps, 230 volts complete all as specified and directed
S&F socket piano, flush type, 6 pin 16 Amps, 230 volts complete all as specified and directed .
S&F Sheet metal enclosure for DBs,TPN, double door, 415 Volts, 4 ways, vertical type and space for MCCB complete all as specified and directed .
S&F MCCB 3 Pole,415 V, fixed type, 100 Amps with breaking capacity 16 KA complete all as specified and directed .
S&F MCB single pole, 240 Volts, 32 Amp, C Series with breaking capacity 10 KA complete all as specified and directed .
S&F MCB SPN, 240 Volts, 40 Amp, C Series with breaking capacity 16 KA complete all as specified and directed.
M&L for Earthing complete with galvanized steel earth plate electrode 60cmx60cmx6.00mm thick, buried directly in ground vertically (depth of pit not less than 2.25m below normal ground level), with top edge of the plate not less than 1.5m below normal ground level, earth plate surrounded by 15cm thick and packed alternate layers of charcoal dust and common salt, connected with and including earth lead of GI wire 4mm dia (8SWG) by means of bolts, nuts, check nuts and washers of galvanized iron or thimbles and other end of the earth wire connected to electrical equipment/GOD/LA and protected by galvanized iron pipe light grade 15mm dia bore including watering pipe 20mm dia bore GI medium grade (ISI marked) with funnel and wire mesh, including all necessary excavation and earth work, PCC chamber in plain cement concrete (1:3:6) type C-1 and pit cover of precast RCC with MS frame etc and all as shown in electrical plate No 3 of MES Schedule Part-I (2009), complete all as specified and directed. Note(s):- (i) RCC pit cover shall be pre-cast of RCC (1:2:4) type B-1, 80mm thick reinforced with XPM not less than 4Kg/Sqm. (ii) PCC chamber shall be constructed 500 mm away from the edge of earth pit. (iii) Rate shall include earth lead and protection pipe of length 7.5m, excess beyond 7.5m length required at site shall be measured and paid separately. (iv) Earth resistance should be less than 3Ohm. In case the test results are not found below 3Ohm, complete earthing will be redone without any extra cost to Govt. (v) Quoted lump sum / rate shall be inclusive of above all provisions.
Supply, fixing & hanging Energy efficient Ceiling fan (white colour) 1200mm sweep BEE approved 5 star rating, AC single phase, 230V, min air delivery 245 CFM with service value 6.00 including canopies,electronic regulator , three Nos. blades, down rod, double ball bearing with capacitor 2.5 mfd and making connection with and including PVC insulated PVC sheathed copper conductor flexible cable 3 core of suitable size from ceiling rose or connector to fan complete all as specified and directed
M&L for sand cushioning with a layer of dry river sand, 80mm thick before laying of cable and 150mm thick (punned down to 100mm thick) after laying of cables, in trenches/ducts, complete all as specified and directed. Note : Punned down thickness (overall 18cm), shall be considered for measurement and payment.
M&L for brick protection with old size sub class 'B' bricks, laid flat , length of bricks across the route of underground cable complete all as specified and directed .
Supply, laying, jointing, testing and commissioning of Low Tension (LT) XLPE insulated, armoured, heavy duty, electric power cable, cross sectional area 10 Sqmm, 4 core, aluminum conductor, 1100 volts grade under ground cable including both side connection with lugs/thimbles of suitable size etc, laid in trenches, along poles or passing through pipes or laid under floor or through walls etc, complete including taking out old cable & bricks all as specified and as directed. Note: (i) Returning filling, earth work, sand cushioning and brick cover for protection of cable shall be measured and paid separately.
Supply, laying, jointing, testing and commissioning of Low Tension (LT) XLPE insulated, armoured, heavy duty, electric power cable, cross sectional area 16 Sqmm, 4 core, aluminum conductor, 1100 volts grade under ground cable including both side connection with lugs/thimbles of suitable size etc, laid in trenches, along poles or passing through pipes or laid under floor or through walls etc, complete including taking out old cable & bricks all as specified and as directed. Note: (i) Returning filling, earth work, sand cushioning and brick cover for protection of cable shall be measured and paid separately.
S&F GI pipe, light grade, 40mm bore, for cable protection, fixed to pole/wall with MS clamps, nuts, bolts etc or laid under floor/road/pavement complete all as specified and directed. Note : (i) Excavation and earth work shall be measured and paid separately.
S&F pre-stressed cement concrete pole, 9 metre long of cross section 102mm x 172mm at top and 102mm x 279mm at bottom, class 10, complying with requirements of IS-1678-1998, errecting truly in vertical position including painting of poles with two coats of synthetic enamel paint over a coat of primer in alternate strip of 30cm each in black and white colour upto 1.5 metre height from top of PCC pedestal/coping of poles and numbering of poles with synthetic enamel paint black in 80mm high letters over 150mm x 230mm yellow base made from synthetic enamel paint complete all as specified and directed
M&L for Stay assembly comprising of 7/8 SWG galvanised stay strand complete with GI stay rod 16mm dia ,mild steel stay plate, stay bow,connecting bracket of suitable mild steel flat , nuts, bolts, washers,loop type insulators etc complete all as specified in electrical plate No I of SSR-2009 (Part- I) complete all as specified and directed.. Note:- Excavation and earth work , PCC shall be measured and paid separately under relevant items of BoQ’.
S&F Shackle type insulator, porcelain, vitreous ,white, brown or green insulator including galvanised mild steel straps,washers, insulator bolts,washers and nuts,working pressure 1100 Volts,height 75 mm ,maximum dia 90 mm including 31x3 mm galvanised steel straps and 12 mm dia of bolts complete all as specified and directed.
M&L for PCC 1:3:6 type C-2 (using 40mm graded crushed stone aggregates) as in foundation,filling & mass concrete complete all as specified and directed
M&L for PCC 1:2:4 type B-1 (using 20 mm graded crushed stone aggregates) as in coping of poles etc including weathering, slightly rounded or chamfered angle and throating, necessary form work and fair finishing all exposed faces of concrete without using extra cement complete all as specified and directed
S&F Aluminium conductor steel reinforced (ACSR), stretched on HT/LT poles without any kink and bends of various sizes complete including fixing to insulator with aluminium binding wire and coloured sleeved jumper connection with PG clamps including cutting of tree branches falling on the site of work complete all as specified and directed . Note: The size of conductor shall be as directed by Engr-in- Charge.
S&F Cross arms, bracing, supports, clamps and back plates, fabricated from structural steel section Fe-290 grade E-165 quality including nuts, bolts, washers, and welding, bending cold or hot, drilling holes for bolts, in any shape or size as directed including two coats of alminium paint over a coat of red oxide primer complete all as specified and directed.
Supply, fixing and testing LED flood light fitting of 160Watt fitted on 4 to 9 meter high octagonal pole / wall /Swan neck pole including LED lamps complete with body robust, corrosion, resistant, superior finish and without any cracks or through holes, made in a single piece by high pressure die cast aluminium alloy. The luminaries shall be monolithic construction totally enclosed dust and water proof with minimum IP-66 protection as per IS-10322-1982 (Part-I) with latest amendments and input voltage range 140-300V, AC, frequency 50-60 Hz, PF should be more than 0.9 with total harmonic distoration THD (I) less than 15%, cool white colour and lamp starting time should not be more than 10 second, Fittings should be provided with 10 KV surge protection. Driver should be constant current constant voltage driver. Driver should have high voltage withstanding capacity upto 300V, AC. Driver should also have double phase protection, no load, open circuit and short circuit protection. LED flood light fittings should be suitable for ambient temperature from - 10 degree centrigrade to 50 degree centigrade and humidity level 10% to 90% RH. Covers should be polycarbonate/ toughened glass to ensure minimum IP 65 degree protection. Cover should not degrade due to heating and ageing. The efficieny of LED luminaries system shall be more than 85 lumens per watt and must be certified by LM-79 test report fixed on and including bracket of 40mm dia,light grade ,GI pipe ,1.20 m and connecting with twin core twisted flexible copper conductor cable 2.5 Sqmm complete all as specified and directed . Cat Part No JETAIRISFLS160WLED757PWBLTG(HSN CODE 9405) of Havells or equivalent make as mentioned in List of makes given in PS Note: (a) Bidder shall submit test report of LED street light fitting from Govt approved accredited test laboratory for LM-79. (b) Bidder has to furnish a replacement warranty of 05 years for LED light fittings complete including lamps from the date of completion of CA. The product will be replaced free of cost in the following cases : - (i) Manufacturing defects, (ii) Failure due to mechanical and electrical impact, (iii) Drop in lumen (or lux at 1m) below 90% of claimed values of lumen (or lux at 1m) of the LED/ luminairies. (c) All LED light luminaire must meet the provision laid down in IS-16101, 16102 Part-I/II, 16103 Part-I, 16104, 16105, 16106, 16108/2012 and 15885 Part-II/ Section 13 (d) scope of work shall include needful T & P and required accessories etc as per manufacturers recommendation complete including making connection, testing etc complete. Note: Every light fitting will be warranty 5 years after completion of CA and replacement/defects as applicable should be complied/rectified within 7 days .
ROYAL BUILDERS
M/S BSS AND SONS
M/S RAJESH KUMAR and CO.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .