Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.4 LAccepted-AOC 63 2ND MAIN ROAD NGO COLONY ADAMBAKKAM CHENNAI 600 088 | CHENNAI | CHENNAI | TAMIL NADU | 600088 | L1 | Accepted-AOC Accepted being L1 Bidder | |
| 2 | L2₹40.8 L+₹2.9 L (7.51%)Rejected-AOC NO 235 PSK ILLAM SANKARAN NAGAR CHINNAMMAN KOIL STREET AVADI CHENNAI 600 054 | CHENNAI | THIRUVALLUR | TAMIL NADU | 600054 | L2 | Rejected-AOC Rejected not being L1 | |
| 3 | L3₹45.3 L+₹7.3 L (19.2%)Rejected-AOC 1 6 620 CHAITANYAPURI INDRA NAGAR DILSUKHNAGAR HYDERABAD TELANGANA 500060 UDYAM TS 09 0007870 37AAEPO0535A1Z8 B 36AAEPO0535A1ZA R MSME STATUS AS VERIFIED | RANGA REDDY | TELANGANA | 500060 | L3 | Rejected-AOC Rejected not being L1 |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
25 May 2020, 6:00 pmClosed
CWE NAVY CHENNAI
Commander Works Engineers Navy Military Engineer Services INS Adyar Old Building Fort St George Rajaji Salai Chennai 600 009
82415 REPAIRS TO EXTERNAL ELECTRIFICATION INCLUDING HT LT AND REPAIR OVERHAULING TO TRANSFORMERS, INTERNAL ELECTRIFICATION AND CERTAIN MISCELLANEOUS REPAIRS TO E/M FITTINGS AND FIXTURES AT VARIOUS LOCATIONS IN CHENNAI UNDER AGE (I) NAVY CHENNAI
2020_MES_333182_2
82415
Open Tender
Civil Works
Item Rate
330 days
CHENNAI
Please refer tender documents
8 documents required · 8 mandatory
₹500
AGE(I) NAVY CHENNAI
₹96,000
Yes
19 Jun 2020
9 May 2020
26 May 2020
9 May 2020
25 May 2020
11 May 2020
Amount
Excavation in trenches not exceeding 1.5 mtrs wide and not exceeding 1.5 mtrs deep in hard /dense soil for laying underground cables and post holes complete all as specified and directed.
Returning filling in including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick in hard/ dense soil complete all as specified and directed.
Removing surplus soil to a distance not exceeding 50 m and depositing at a level not exceeding 1.5m above the starting point all as specified and directed.
Supply and spread fine river sand in trenches for cable cushioning on top and bottom of cable as specified for cable protection complete all as specified and directed. Note: (i) Only punned thickness of river sand shall be measured (ii) Riddled earth shall be used in lieu of river sand after obtaining written permission from AGE (I)
Supply and lay burnt clay bricks, sub class "B", Designation 75, keeping the width of the brick parallel to the length of the cable complete all as specified and directed.
Material and labour for PCC (1:4:8), type D-2, using 40 mm graded stone aggregate as in foundation, filling and mass concrete all as specified and as directed.
Material and labour for PCC 1:3:6, type C-1, using 20 mm graded stone aggregate, as in foundation/ coping of poles including necessary form work and finishing the exposed concrete surfaces even and fair complete all as specified and as directed
Dismantling of GI earth/guard wire of any size and removing unserviceable GI wire from site complete all as specified and as directed.
Dismantling of old unserviceable stay assembly including stay wire complete with necessary demolition of concrete, excavation and earth work as required and removing the same from site complete all as specified and as directed.
Dismantling of old unserviceable steel tubular pole & removing and taking into credit including necessary demolition of concrete, foundation including connected earthwork etc... all as specified and as directed.
Material and labour for dismantling concrete poles/struts, any size & removing and taking into credit with necessary demolition of concrete foundation including connected earth work etc... complete as required all as specified and as directed.
Dismantling of cross arms of MS channel or angle section etc... complete fixed on RCC/steel tubular poles carefully including separating and setting aside serviceable cross-arms for reuse in the work and removing unserviceable cross arms complete all as specified and as directed.
Dismantling of insulators of any type & size from position including separating & setting aside serviceable insulators for reuse in the work and removing unserviceable insulator from site complete all as specified and as directed.
Dismantling air break gang operated switches vertical/horizontal mounted including insulators and operating mechanism for repair/ replacement complete all as specified and directed.
Dismantling drop out fuse vertical/horizontal mounted including insulators for repair/ replacement complete all as specified and directed.
Dismantling and removing of GI pipe from trench/wall etc... of size 40 mm to 100 mm dia, complete all as specified and directed.
Dismantling of lightning arresters of any type & size from position and removing from site complete all as specified and as directed.
Dismantling of anti climbing device, any type & size from position and removing from site complete all as specified & as directed.
Dismantling and removing from trench/duct etc... old armoured, XLPE insulated HT electric power cables and keeping in safe custody, complete all as specified and directed.
Dismantling and removing from trench/duct etc., old armoured, XLPE insulated LT electric power cables of any size and keeping in safe custody complete all as specified and directed
Material and labour for steel tubular swaged poles complete with cast iron base plate,finial tapper plug, bolt,nuts & screws etc.., type 410 SP-31 (9.0 metres long) and fixing in concrete foundation, including two coats of aluminium paint over a coat of red oxide primer complete all as specified and directed. (Note: Earthwork, excavation, RFR, removal of surplus soil and concrete shall be measured and paid separately)
Material and labour for prestressed concrete pole, 9.0 metres long, 102 mm x 152 mm at top and 102 mm x 289 mm at bottom, class 10, and fixing in concrete foundation, including two coats of cement base paint over a coat of primer complete all as specified and directed. (Note: Earthwork, excavation, RFR, removal of surplus soil and concrete shall be measured and paid separately)
Supply, laying and testing of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, heavy duty electric power cables with stranded aluminium conductor of cross sectional area 70 sqmm 3 core, 11000 volts grade, complete all as specified and directed. (Note: Earthwork, excavation, RFR, removal of surplus soil, river sand cushioning and PCC cover slab/ bricks for cable protection shall be measured and paid separately)
Supply, laying and testing of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, heavy duty electric power cables with stranded aluminium conductor of cross sectional area 95 sqmm 3 core, 11000 volts grade, complete all as specified and directed. (Note: Earthwork, excavation, RFR and removal of surplus soil, river sand cushioning and PCC cover slab/ bricks for cable protection shall be measured and paid separately)
Material and labour for cradle guarding, hexagonal / rectangular fabricated with 4mm dia GI wire all as specified & directed
Supply and fix cross arms, bracing, support, clamps etc made out of mild steel channel or angle section of reqd size and shape including clamp, back plate with bolts, nuts & washers drilled for insulator bolts, welding, bending cold or hot in any shape or size including all fixing arrangement on HT over head line and painted with two coats of aluminium paint over a coat of red oxide primer complete all as specified and directed.
Fixing only old serviceable cross-arms obtained from dismantling here-in-before including providing new bolts, nuts and washers as required including painting with one coat of aluminium paint over a coat of red oxide primer after preparation of old surfaces complete all as specified and as directed.
Material and labour for anti-climbing devices, spike type fabricated from MS bar (8 mm size 10 Nos x 20 cm long) fixed by drilling/welding on 2 Nos. MS flat 40 x 6 mm, made to shape to suit the cross section of the pole and fixed at about 2.0 mtr height from GL including complete painting with two coat of aluminium paint over a coat of red oxide primer all as specified and directed.
Material and labour for danger notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones painted with synthetic enamel paint in signal red colour and fixed with MS clamps, bolts & nuts of approved size of HT 250 x 200 mm size complete all as specified and directed.
Material and labour for surge or lightening arrester, metal oxide type for HT distribution line, nominal discharge current 10 KA, high current impulse with stand 63 KA (10 ms impulse) CL-I confirming to IS 3070 and IEC - 60099 - 4 including all fixing arrangement on HT pole complete all as specified and directed.
Supply and fix in replacement for electromat high voltage mats conforming to IS 15652-2006 suitable for 11 KV ,thickness of 3.00 mm, width 1.5 mtrs with SR-998 and fixed with suitable adhesive of Pidilite complete all as specified and as directed. Make : Electromat or equivalent as approved by AGE (I)
Supply and replacement of Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm all as specified and directed. Make : Raychem's/Densons/M-Seal/Birla-3M/Yamuna gases & chemicals
Supply and fixing (in replacement) of Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm all as specified and directed Make : Raychems/Densons/M-Seal/Birla-3M/Yamuna gases & chemicals
Supply and fixing (in replacement) of Cable jointing kit for 11 KV (Earthed) grade cable for straight through cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm all as specified and directed Make : Raychems/Densons/M-Seal/Birla-3M/Yamuna gases & chemicals
Supply and fixing of XLPE insulated screened PVC bedded galvanised steel strip or wire armoured electric cable(heavy duty) (LT UG) with aluminium conductor 1100 volts grade cross sectional area 3½ core 300 sq mm in trenches/on truss/wall/floor, through pipe with MS clamps all as specified and directed Note: Earthwork, excavation, RFR,removal of surplus soil, river sand cushioning and PCC cover slab/ bricks for cable protection shall be measured and paid separately
Description all as per Sl item No. 35 described here-in-before but of size 240 sq mm 3½ core
Description all as per Sl item No. 35 described here-in-before but of size 70 sq mm 3½ core
Description all as per Sl item No. 35 described here-in-before but of size 50 sq mm 3½ core
Description all as per Sl item No. 35 described here-in-before but of size 35 sq mm 3½ core
Supply and fixing of Stay assembly complete with following mentioned accessories as shown in electrical plate No. 1 including dismantling old unserviceable stay assembly complete and depositing where directed at site all as specified and as directed:- (i) GI stay rod 20 mm dia, 2150 mm long (ii) MS stay plate of size 300 x 300 mm, 6mm thick including bolts & nuts (iii) Stay GI stay bow Note : Excavation, earthwork, foundation concrete, stay wire, clamps and loop insulator shall be measured and paid separately under relevant items.
Supply and fix loop type insulator vitreous porcelain white, brown or green small size with overall dimensions 90 x 140 mm and clearance of hole 25.5 mm complete all as specified & as directed.
Supply and fix galvanised stay strand of size 7/4 mm / 7/3.15mm with necessary binding work complete all as specified and as directed.
Supply and fixing of Pin type porcelain, vitreous, white, brown or green insulator of size 100 mm height, 65 mm dia for 1100 volts grade, including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron bolt all as specified and as directed.
Description all as per Sl item No. 43 described here-in-before but 150mm height, 150mm dia for 11000 volts grade
Supply and fixing of Disc type insulator, porcelain, vitreous 145 mm height and 255 mm dia ball and socket type white, brown or green, single disc assembly for tension clamps for conductors working pressure 11000 volts all as specified and as directed
Supply and fix Shackle Type, Porcelain, vitreous, white, brown or green insulator including galvanised mild steel straps, washers,insulator including galvanised mild steel straps, insulator bolts, washers and nuts, for conductors working pressure 1100 volts all as specified and as directed
Material and labour for trenchless cutting (Non Man Entry Type) by HDD (Horizontal Directional Drilling ) method for boring a hole under road, pavement, hard standing including laying of HDPE (High Density Polyethylene) pipe of 150mm dia suitable for 0.4 Mpa (Mega Pascal) working pressure complete all as specified as per the IS Codes of Practice suiting Indian Conditions published by the Indian Society for Trenchless technology from time to time and as directed by GE. Note : The entire trenchless equipment shall be operated by the contractor strictly as per manufacturer's operation manual and a copy of same shall be provided to AGE (I) by contractor.
Supply and replacement of GI tubing, medium grade, 100 mm , galvanized with all fitting laid in trenches/road crossing etc... for UG cable protection all as specified and as directed
Description all as per Sl item No. 48 described here-in-before but 80 mm dia
Description all as per Sl item No. 48 described here-in-before but 50 mm dia
Description all as per Sl item No. 48 described here-in-before but 40 mm dia
Supply and fix Synthetic Insulating Mat of size 2 metre x 1 metre x 19 mm thick and removing old unserviceable mat from the site complete all as specified and directed
Supply and spread crushed stone aggregate not exceeding 40mm size, 150 mm thick layer over well prepared sand bed layer all as specified and as directed.
Supply and spread M-sand not exceeding 300 mm thick all as specified and as directed.
Servicing of two pole structure complete including replacement of unserviceable jumpers, sleeves, vice type connectors, bolts nuts washers connecting lugs/thimbles greasing the moving parts applying petroleum jelly on moving and fixed contacts, tightening all connection and preparing the old painted surfaces of the structure such as poles, cross arms, bracings and supports clamps back plates etc... complete and applying two coats of anti corrosive aluminium paint over a coat of red oxide zinc chrome primer and providing yellow and black paint from the ground level all as specified and as directed at site by Engineer-in-Charge. Note : No extra payment will be made for the spares required to keep the installation in satisfactory functioning through out the contract period other than given in the schedule
Servicing of four pole structure complete including replacement of unserviceable jumpers, sleeves, vice type connectors, bolts, nuts washers connecting lugs/thimbles greasing the moving parts applying petroleum jelly on moving and fixed contacts, tightening all connection and preparing the old painted surfaces of the structure such as poles, cross arms, bracings and supports clamps back plates complete and applying two coats of anti corrosive aluminium paint over a coat of red oxide zinc chrome primer all as directed at site by Engineer-in-Charge. Note : No extra payment will be made for the spares required to keep the installation in satisfactory functioning through out the contract period other than given in the Schedule
Material and labour for painting of LT/HT steel tubular pole with one coat of aluminium paint and black paint upto 1.2 meter from the bottom of the pole after preparing the existing surface of the poles and marking the poles numbers as per existing pattern including fixing two no fluorescent tape 50 mm width, around the pole at 1.2 meter height, complete all as per specified and as directed.
Supply and fix in replacement of MCCB 4 pole 415 volts on panel mounted type with breaking capacity 16/36 KA, Magnetic thermal setting adjustable 70-100% including disconnecting the incoming/outgoing cable connections and re-connecting with suitable aluminium lugs/ferrules etc after taking out the existing unserviceable MCCB and making good the disturbed surface for following capacity all as specified and as directed. Make : L&T / Legrand/ABB/Siemens/Schneider
MCCB four pole 45 volts 50 Hz, 500 Amps, with rupturing capacity 36 KA
MCCB four pole 45 volts 50 Hz, 630 Amps, with rupturing capacity 50 KA
Supply, install, commissioning and testing of air break switch gang operator off load disconnection type, out door, mechanically operated (with GI operating rod) from ground level and mounted on 11KV post insulators with and including MS channel base, MS nut, bolts for fixing to the poles, capacity 200 A, 3 phase and three insulators per phase complete with locking arrangement in ON and OFF position including necessary connections and fixing to the pole structure in position including painting the steel surface with two coats of aluminium paint over a coat of red oxide primer etc... all as specified and as directed.
Supply and fix in replacement of drop out fuses 11 KV, 100 Amps capacity including nut, bolts, washers with barrel fuse expulsion type set of three including mounting on channel complete all as directed
Material and labour for earthing complete with copper earth plate of size 600 x 600 x 3.15 mm thick, buried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of earth plate not less than 1.5m below normal ground level, connected to 20 x 3.15 mm copper strip by means of bolts, nuts, check nuts and washers of galvanized iron or steel complete with 40mm bore GI light grade protection pipe, 20mm bore GI medium grade watering pipe with funnel including charcoal dust, salt, PCC M-15 type B1 in pit with precast RCC M-15 type B1 in cover reinforced with XPM not less than 4Kg per Sqm, test point etc, all as shown in electrical plate No. 3 of SSR Part - I (2009) Specifications complete with necessary earth work in any type of soil, removal to a distance not exceeding 50m including testing on completion, complete all as specified and as directed by Engineer-in-Charge. Note : The cost of excavation, earth work, PCC pit, CI cover, funnel, watering pipe, wire mesh, charcoal dust, common salt, 20mm bore medium grade, 40mm bore light grade GI pipe as protection to earth lead strip shall be deemed to be included in the quoted rate.
Material and labour for GI Chain link fencing including line wires, any mesh, size and type of standard rail, straining bolts with necessary angle or 'J' section fixed independently without connecting plate including making holes for fixing chain link fence, complete all as specified and directed.
Material and labour for MS Gate made out of angle iron of suitable size with necessary joining accessories, welding etc... as required, steel confirming to Gde Fe - 290 (Gde E-165) complete all as specified and directed. Note : Necessary earthwork excavation, PCC for foundation shall be measured and paid separately.
Material and labour for disconnecting carefully electrical connection from HT/LT sides of the transformer, keeping them at safe sides and taking out the transformer Out door type 201 to 400 KVA, 0.433/11KV, comprising step up any make, carrying out complete overhauling which shall comprise of the following :-
(a) Material and labour for lifting, transporting, handling, the transformer to work shop and opening top cover of the transformer by unscrewing nuts, bolts, washers etc including disconnecting core assembly from HT/LT bushing and lifting the same gently and taking out from the shell (container/ body) of the transformer. (b) Material and labour for draining out transformer oil from the above said transformer in the suitable capacity of container /drums and keeping it in safe custody for reuse. (c) Material and labour for cleaning of the transformer body from inside, removing deposited dirt / sludge/ foreign particles etc from the bottom / body of the transformer and drying/ heating up the shell from inside before refilling of the transformer oil.
(d) Material and labour for checking the leakage of transformer oil from tank joints, bushings, inlet/out let valves ,breather etc ,servicing, penning the transformer and disconnect the star and delta connection for HT and LT windings ,testing the insulation resistance, cleaning and washing thoroughly core and windings of the transformer by hoisting down with clean dry oil conforming to IS 335/1983, removing deposited dirt/sludge/foreign particles from the windings / core and re-varnishing of the windings with super varnish including heating/drying/backing complete carefully and thoroughly inside the heating chamber at suitable temperature to obtain required value of insulation resistance etc all as per IS 1986-87 and directed by Engineer-in- charge.
(e) Lifting and refixing core assembly inside the transformer shell gently and carefully, connecting of HT / LT/ Neutral connections to the bushings assembly, fixing of tap change over including tightening of nuts, bolts, washers of the core to reduce humming noise all as directed by Engineer-in- charge. (f) Varnishing the entire core assembly with insulating oil of approved quality ,heating and drying thoroughly, re -insulation paper, press pan paper, fevicol, sleeves and heating carefully inside chamber to got required megger value so as to obtain desired insulation resistance all as directed. (g) Re- fixing of the core assembly inside the transformer shell gently and carefully , connecting up with the HT/LT bushings, fixing of tap changer, connecting up with the neutral connections etc complete all as specified and directed by Engineer-in- charge Note: Necessary dismantling of core assembly for repair/rewinding and refixing shall be measured and paid under relevant items here in before all as specified and directed by Engineer-in- charge .
(h) Refilling the transformer oil in the shell of transformer only after carrying out filtration and heating up oil upto 105 degree C to achieve required dielectric strength and submitting the test result before and after filtration of oil in presence of Engineer- in- charge on proper proforma duly signed. (j) Refixing the top cover including replacement of cork sheet/ gasket 8mm thick, tightening of nuts /bolts /washers etc and replacement of breather with silica gel crystal type all as directed by Engineer-in charge. (k) Material and labour for carrying out acidity test of transformer oil all as per IS-1866/1961 in presence of Engineer-in-charge or MES representative authorised by him and submitting the test results on proper proforma duly signed. (l) Cleaning / scrapping / brushing down and preparing the outer surface of the transformer body and painting with two coats of synthetic enamel paint over one coat of primer all as specified and directed by Engineer-in- charge.
Note:- (i) Any damage to insulators/bushes/windings etc... while in the custody of the contractor shall be made good at no extra cost to govt. The serviceability of the transformer shall be checked and confirmed by the contractor before taking into his custody. (ii) The job taken for repair / over hauling should be complete with in 48 hours from the date of handing over the individual transformer , failing which neccessary arrangement to be made by the contractor at no extra cost. (iii) Filling up of the transformer oil will be measured and paid seperately. (iv) While taking transformer to the work shop the contractor has to temporarily install and connect transformer provided by the department as the same is catered for maintenance of essential services. (v) Necessary rewinding of core if required will be measured and paid seperately
Description all as per Sl item No. 64 here-in-before but for Transformer of capacity 101 to 200 KVA.
Cleaning / scrapping / brushing down and preparing the outer surface of the transformer body and painting with two coats of synthetic enamel paint over one coat of primer all as specified and directed.
Dehyderation, filteration of transformer oil using stream line filter to obtain a dielectric strength above 40 KV, including all arrangement for DG set, filteration plant, filter paper etc... all as directed and specified.
Supply and Filling the new transfermer oil of approved make conforming to IS- 335 including filtration of existing and taped up oil so as to achieve IR value of the oil not less than 40 KV and all as specifaied and all as directed.
Material and labour for rewinding of damaged / burnt out HT / LT coil , servicing of step down transformer of capacity 100 to 400 KVA capacity 11000/433 volts, comprising the following:- (a) Removing the transformer core assembly by un-screwing the nuts, bolts, washers of top cover, draining out the exiting oil removing the HT / LT bushings etc and taking out the core gently with the help of necessary tools arrangement complete and all as directed. (b) Dismantling and taking the burnt HT coils from the core assembly and cleaning the other coils and core assembly with CTC solution including removing the deposited dirt/foreign materials etc complete. (c) Rewinding the HT/LT coils with super enamelled copper winding wire of existing size including insulating materials etc complete ,refixing the rewinded HT/LT coils on the core assembly connecting up with the tap changer etc all as specified and directed.
Material and labour for disconnecting and dismantling unserviceable damaged LT bushing, studs complete of 100 KVA Transformer, any make 11/0.433 KV and replacing the same with supplying and fixing, connecting and commissioning LT porcelain bushings with gun metal threaded studs of suitable lengths including metal rings/nuts/bolts/washers, rubber rings etc (set of 4) all as specified and as directed.
Description all as per Sl item No. 70 here-in-before but HT bushing complete (set of 3)
Description all as per Sl item No. 70 here-in-before but for 200 and 400 KVA transformer 11000/433 volt, any make all as specified and as directed.
Description all as per Sl item No. 70 here-in-before but HT bushing complete (set of 3) for 200 and 400 KVA transformer 11000/433 volt, any make all as specified and as directed.
Supply and replace transformer breather assembly with dry silica gel all as specified and as directed.
Supply and replace dry silica gel of transformer breather all as specified and as directed .
Supply and fix in replacement of Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe of 25 mm dia all as specified and as directed.
Cleaning / scrapping / brushing down and preparing the outer surface of the transformer body and painting with two coats of synthetic enamel paint of transformer from 200 KVA to 400 KVA capacity of approved make all as specified and as directed.
Taking out vacuum circuit breaker by disconnecting carefully electrical connection from incoming and out going from panel carefully, overhauling the spring charging mechanism, checking the vacuum gap, greasing and adjusting of moving parts and adjusting as required, cleaning all parts by CTC solution / emery paper as required and greasing the metallic and mechanical serviceable parts all as specified and as directed.
Removing, cleaning, servicing, calibration, testing and commissioning of microprocessor based earth fault and over current fault relay all as specified and as directed.
Removing, cleaning, servicing, calibration, testing and commissioning of electro magnetic earth fault and over current fault relay all as specified and as directed .
Replacement of Fuse carrier including HRC fuse upto 10 Amps suitable for operating voltage 110/220 Volt for HT/LT Panel all as specified and as directed.
Supply and fix in replacement push button switch suitable for operating voltage 110/220 Volt for HT/LT Panel all as specified and as directed.
Supply and fix in replacement indicator lamp LED suitable for operating voltage 110/220 Volt for HT/LT Panel all as specified and as directed.
Supply and fix 11 KV resin cast current transformer (250/5A) all as specified and as directed.
Supply and fix 11 KV potential transformer complete all as specified and as directed.
Preparing the outer surface of VCB panel indoor type by removing the old paint/removing the rusting and denting and painting with two coats of synthetic enamel paint of approved colour complete all as specified and as directed.
Supply and fixing in replacement of off load Change over switch in sheet metal enclosure 4 pole 415 volts side handle operation along with fixing arrangements with suitable nut, bolts, washers etc... including terminating the incoming/outgoing cables with suitable aluminum lugs/ferruls with propper crimping and testing for 400Amps comlete all as specified and directed.
Supply and fix in replacement of off load Change over switch in sheet metal enclosure 4 pole 415 volts side handle operation along with fixing arrangements with suitable nut, bolts, washers etc... including terminating the incoming/outgoing cables with suitable aluminium lugs/ferrules with proper crimping and testing complete for 200 Amps all as specified and as directed by Engineer-in-charge.
Cutting the existing bituminous road/hard standing (45 cm width and 60 cm depth) and making good the disturbed surface after laying pipes/ cables, by using PCC (1:4:8), type D-2 using 40mm aggregates at the top for a depth of 15 cm and remaining portion to be covered with excavated soil, properly rammed, complete all as specified and directed.
Dismantling APFC panel carefully, removing the defective control device MCCB / MCBs, capacitors, indicator cum push button switches, relays, contacts, CTs, internal wiring, cleaning all parts by CTC solution / emery paper as required and greasing the metallic and mechanical serviceable parts all as specified and as directed.
Supply and fix relays BR 6000 suitable for 6 stage APFC panel Make:Epcos/Neptune/Siemens/ABB/Schneider/L&T
Supply and fix relays BR 6000 suitable for 8 stage APFC panel Make: Epcos/Neptune/Siemens/ABB/Schneider/L&T
Programming and tuning of relays suitable for APFC panel
Supply and fix capacitor
Supply and fix fresher fan suitable for APFC panel
Supply and fixing (in replacement) of MCCB 3 pole 415 volts on pannel mounted type with breaking capacity as mentioned below Magnetic thermal setting adjustable 70-100% including disconnecting the incoming/outgoing cable connections and re-connecting with suitable aluminum lugs/ferruls etc. after taking out the existing u/s and making good the disturbed surface for following capacity. Make : ABB/L&T/Legrand/Siemens/Schneider
MCCB 63 Amps, 16KA
MCCB 100 Amps, 16KA
MCCB 160 Amps, 36KA
MCCB 250 Amps, 36KA
MCCB 320 Amps, 36KA
MCCB 400 Amps, 36KA
MCCB 500 Amps, 36KA
Supply and fixing (in replacement) of MCB 3 pole 415 volts on pannel mounted type with breaking capacity 10 KA including disconnecting the incoming/outgoing cable connections and re-connecting with suitable aluminum lugs/ferruls etc. after taking out the existing u/s and making good the disturbed surface for following capacity:- Make : ABB/L&T/Legrand/Siemens/Schneider
MCB 32 Amps, TP
MCB 40 Amps, TP
MCB 63 Amps, TP
MCB 6-32 Amps, SP
Supply and fixing in replacement for power contactor capacitor duty 3 pole, 415 volts on panel mounted type including disconnecting the incoming/outgoing cable connections and re-connecting with suitable copper lugs/ferruls etc... after taking out the existing unserviceable and making good to the disturbed surface for following capacity:-
Contactor suitable for up to 12.5 KVAR
Contactor suitable for above 12.5 KVAR to 20 KVAR
Contactor suitable for above 20 KVAR to 25 KVAR
Contactor suitable for above 33.3 KVAR to 50 KVAR
Supply and fix illuminated push button switch suitable for APFC Panel all as specified and as directed
Demolition of concrete of any description and in any position not otherwise specifically provided for all as specified and as directed
Material and labour for preparation of old steel surfaces of HT/LT Feeder Pillar Box of any description, over 10cm in width or girth not otherwise described and applying one coat of synthetic enamel paint complete all as specified and directed.
Material and labour for brick work with sub class 'B' straight or curved on plan exceeding 6m mean radius built in cement mortar (1:4) all as specified and as directed.
Material and labour for 10mm thick rendering in cement plaster (1:4) on brick or concrete surfaces finished fair and even without using extra cement all as specified and as directed.
Supply and fix mild steel chequered plate 5 mm thick, complete all as specified and directed
Taking down carefully copper / aluminium point wiring (light, fan, socket or power) complete including fittings such as switches, ceiling roses, pendants, regulators, sockets etc..., removing materials for taking into credit and making good disturbed surfaces of walls, floors, etc., all as specified and as directed.
Material and labour for Point wiring complete with FRLS PVC insulated unsheathed cable 1100V grade conforming to IS-694, 1.5 Sqmm (nominal area) multistranded with copper conductor drawn through and including non metallic rigid PVC conduit 20mm dia (ISI marked) and accessories, concealed in wall / surface on ceiling with sunken type pressed steel / welded terminal boxes made out of 2 mm mild steel sheet, of suitable module including provision of FRLS PVC insulated unsheathed 1.5 Sqmm FRLS multistranded with copper conductor as earth continuity conductor and connecting to common earth dolly complete all as specified and as directed for the following:-
One light point controled by one switch
One fan point controlled by one regulator/ switch
One 3 pin socket outlet 5 amps socket on independent board
One 3 pin socket outlet 5 amps socket on same board
One light point controlled by 2 number of two way switches
One bell/buzzer point controlled by one push button
Description all as per Serial item No. 104 here-in-before but with 2.5 sqmm cable for one 3 pin socket outlet 15 Amps on idependent board with 2.5 sqmm cable as earthing conductor
Supply and fix socket outlet 2 in 1, 3 pin, 5 Amps complete all as specified and as directed.
Supply and fix switch piano flush type single pole, one way, 5 Amps, 240 volts complete all as specified and directed.
Supply and fix switch piano flush type single pole, two way, 5 Amps, 240 volts complete all as specified and directed.
Supply and fix switch socket combination 2 in 1, 5 Amps flush type 240 volts complete all as specified and as directed.
Supply and fix switch socket combination 5 in 1, 5/16 Amps flush type 240 volts complete all as specified and as directed.
Supply and fix ceiling rose, 3 phase PVC polycarbonate, isolated body, complete all as specified and directed.
Supply and fix Call bell (Ding - dong) electric suitable for working on 240 volts AC supply complete all as specified and as directed.
Supply and fix in repair stepped type electronic fan regulator flush type on the exisiting phenolic laminated sheet complete all as specified and directed.
Supply and fix in repair switch piano flush type single pole, one way, 5 Amps, 240 volts, including taking down old unserviceable switches and removing the material for taking credit complete all as specified and directed.
Supply and fix in repair switch socket combination 2 in 1, 5 Amps flush type, 240 volts, including taking down old unserviceable switch socket combination and removing the material for taking credit complete all as specified and directed.
Supply and fix in repair switch socket combination 5 in 1, 5/16 Amps flush type 240 volts including taking down old unserviceable switch socket combination and removing the material for taking credit complete all as specified and directed.
Supply and fix in repair ceiling rose, 3 phase PVC polycarbonate, isolated body including taking down old unserviceable ceiling rose and removing the material for taking credit complete all as specified and directed.
Supply and fix in repair switch flush type single pole, two way, 5 Amps 240 volts including taking down old unserviceable switches and removing the material for taking credit complete all as specified and directed.
Supply and fix in repairs Call bell (Ding - dong) electric suitable for working on 240 volts AC supply including taking down old unserviceable call bell and removing the material for taking credit complete all as specified and directed.
Supply and fix in repair stepped type electronic fan regulator flush type on the exisiting phenolic laminated sheet including taking down old unserviceable electronic fan regulator and removing the materials for taking credit complete all as specified and directed.
Supply and fix in repair Bell push flush type 5 Amps 240 volts including taking down old unserviceable bell push and removing the materials for taking credit complete all as specified and directed.
Supply and fix in repair Modular switch 1 way 5 Amps, 1 module including taking down old unserviceable swithc and removing the materials for taking credit complete all as specified and directed.
Supply and fix in repair Modular switch 1 way 16 Amps, 1 module including taking down old unserviceable swithc and removing the materials for taking credit complete all as specified and directed.
Supply and fix in repair Modular bell push 5 Amps, 1 module including taking down old unserviceable bell push and removing the materials for taking credit complete all as specified and directed.
Supply and fix in repair Modular socket 5A-2/3 pin combined 2 module including taking down old unserviceable bell push and removing the materials for taking credit complete all as specified and directed.
Supply and fix in repair Modular socket 5/15Amps -2/3 pin combined 2 module including taking down old unserviceable socket and removing the materials for taking credit complete all as specified and directed.
Supply and fix in repair modular fan regulator step type, 1 module including taking down old unserviceable fan reulator and removing the materials for taking credit complete all as specified and directed.
Supply and fix Modular switch 5 Amps two way flush type including taking down old unserviceable modular switch and removing the materials for taking credit complete all as specified and directed.
Supply and fix Modular white cover plate with frame, 1 module including taking down old unserviceable modular switch and removing the materials for taking credit complete all as specified and directed.
Supply and fix Modular white cover plate with frame, 2 module including taking down old unserviceable modular cover plate and removing the materials for taking credit complete all as specified and directed.
Supply and fix Modular white cover plate with frame, 3 module including taking down old unserviceable modular cover plate and removing the materials for taking credit complete all as specified and directed.
Supply and fix Modular white cover plate with frame, 4 module including taking down old unserviceable modular cover plate and removing the materials for taking credit complete all as specified and directed.
Supply and fix Modular white cover plate with frame, 6 module including taking down old unserviceable modular cover plate and removing the materials for taking credit complete all as specified and directed.
Supply and fix Modular white cover plate with frame, 8 module including taking down old unserviceable modular cover plate and removing the materials for taking credit complete all as specified and directed.
Supply and fix Modular metal flush box 1/2 module including taking down old unserviceablemetal box and removing the materials for taking credit complete all as specified and directed.
Supply and fix Modular metal flush box 3 module including taking down old unserviceablemetal box and removing the materials for taking credit complete all as specified and directed.
Supply and fix Modular metal flush box 4 module including taking down old unserviceablemetal box and removing the materials for taking credit complete all as specified and directed.
Supply and fix Modular metal flush box 6 module including taking down old unserviceablemetal box and removing the materials for taking credit complete all as specified and directed.
Supply and fix Modular metal flush box 8 module including taking down old unserviceablemetal box and removing the materials for taking credit complete all as specified and directed.
Supply and fix 3 mm thick hylem sheet top cover on switch boards including cutting, fixing, screwing etc... Including taking down old unserviceable hylum sheet, removing the material for taking into credit and making good to the disturbed surface of wall complete all as specified and directed.
Supply and fix flushed to wall 2mm thick MS sheet fabricated terminals box of following sizes and dismantling corroded metal box from wall, removing the materials for taking credit and making good the disturbed surface of wall including plastering the sides complete all as specified and directed:-
Supply and fix PVC casing caping of size 25 , ISI marked on wall/roof/ceiling work etc... with all accessories for drawing of any type of cables all as directed at site including and making good the disturbed surface of wall complete all as specified and directed. Note : Drawing out existing cable of any size, keeping it in safe custody, taking down the old unserviceable PVC casing/caping, removing the pipe for taking credit are measured as separate item
Supply and fix PVC conduit of size 25mm ISI marked on wall/roof/ceiling work etc with all accessories for drawing of any type of cables all as directed at site including and making good the disturbed surface of wall complete all as specified and directed. Note : Drawing out existing cable of any size, keeping it in safe custody, taking down the old unserviceable PVC casing/caping, removing the pipe for taking credit are measured as separate item
Description all as per Sl item No. 143 here-in-before but for 32 mm PVC conduits
Description all as per Sl item No. 143 here-in-before but for 40 mm PVC conduits
Removing serviceable wiring of any size from conduit/batten/casing/caping on surface of wall, ceiong and keeping in safe custody for resuse complete all as specified and directed.
Taking down unserviceable PVC conduit/casing/ caping of any size and removing the materials for taking credit complete all as specified and directed.
Supply and fix louvers for exhaust fan of any size including taking down old unserviceable louvers and removing the materials for taking credit complete all as specified and directed.
Supply and fix lamp holder PVC/polycarbonate, isolated body including taking down old unserviceable lamp holders and removing the materials for taking into credit complete all as specified and directed.
Supply of LED batten, wall mounted with decorative end cap of capacity 1 x 22 W (4 feet) or nearest higher wattage, 2500 Lumes, 6500K suitable for surface, wall and conduit mounting complete with all accesories including LED drivers, internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable of suitable size and taking down old unservicable fittings complete all as specified and directed. (Make : Philps: Model- Smart Brite, Cat Part No. BN 021 LED25S 6500 PSU GR S1 or equivalent in Surya/ Wipro/ Bajaj/Crompton/Eveready as approved by AGE (I))
Supply and fix energy saving new generation 10 W LED IP 65, Bulkhead Luminaire, 6500K, efficiency of 110 lm/w, aluminium die cast with polycarbonate optical material and opal diffuser, including necessary accessories and connecting up with twin core twisted flexible copper conductor cable of suitable size, complete all as specified and directed. MAKE: Philips Cat Part No. WT202W LED10S CW PSU S3 PC or equivalent in Bajaj/Surya/Wipro/GE/Eveready/Osram as approved by AGE (I)
Supply of LED batten, wall mounted with decorative end cap of capacity 1 x 10 W (2 feet) or nearest higher wattage, 230 V, 6500K suitable for surface, wall and conduit mounting complete with all accesories including LED drivers, internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable of suitable size and taking down old unservicable fittings complete all as specified and directed. (Make : Philps: Model- Smart Brite, Cat Part No. BN 021 LED10S 6500 PSU GR S1 or equivalent in Surya/ Wipro/ Bajaj/Crompton as approved by AGE (I))
Supply and fix recessed mounting 2 ft x 2 ft LED luminaire 35W or nearest higher wattage 6500 K suitable for grid ceiling with super bright LED etc. complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed. Make : Crompton, Model :POLARIS I Cat Part No.LCTLRN-36-FO-CDLor equivalent in Philips/ Bajaj/Wipro/Surya/Eveready as approved by AGE (I)
Supply and fix LED Mirror light fitting 2 feet,14 W,or nearest higher capacity 230v, wall mounted battern/Surface mounted IP20 rated luminaire with extruded aluminium body and polycarbonate diffuser giving glare free illumination and smooth lighting with nominal efficacy of >75lm/W,with integrated LED driver, etc. complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed. Make : CG, Model :LINNET,Cat Part No.LCL-14-CDL or equivalent in Philips/Bajaj/Wipro/Surya/Eveready/GE as approved by AGE (I)
Supply and fixing of LED 6W light fitting round recess mounting downlighter including lamp and choke etc... all as required at site including taking down old U/S fittings for taking into credit and alteration to False ceiling as required at site complete all as specified and directed . Make : Philips Cat No DN 391B LED6S-6500 PSU WH or equivalent in Bajaj/Wipro/Surya/Eveready/GE as approved by AGE (I)
Supply and fixing of LED 10W light fitting round recess mounting downlighter including lamp and choke etc. all as directed as required at site including alteration to False ceiling as required at site and taking down old U/S fittings for taking into credit complete all as specified and directed. Make : Philips Cat Part No DN 392B LED10S-6500 PSU WH or equivalent in Bajaj/Wipro/Surya/Eveready/GE as approved by AGE (I)
Supply and fixing of LED 20W light fitting round recess mounting downlighter including lamp and choke etc., all as directed as required at site including alteration to False ceiling and taking down old U/S fittings for taking into credit as required at site complete all as specified and directed . Make: Philips Cat Part No DN 395B LED20S-6500 PSU WH or equivalent in Bajaj/Wipro/Surya/Eveready as approved by AGE (I)
Supply & Replace PLC lamp 36 watts 2 or 4 pin 6500K including taking down old unserviceable lamp and removing the material for taking credit complete all as specified and as directed. Make: CG Cat part no. 36 W 4P CFL 6500K or equivalent in Bajaj/Wipro/Philips as approved by AGE (I)
Supply & Replace PLC 36 watts Holder including taking down old unserviceable holder and removing the material for taking credit complete all as specified and as directed.
Supply & Replace PLC 2 x 36 watts Electronic Choke. including taking down old unserviceable choke and removing the material for taking credit complete all as specified and as directed. Make: Bajaj/Wipro/Philips/CG as approved by AGE (I)
Supply & Replace PLC lamp 18 watts 2 pin or 4 pin . including taking down old unserviceable lamp and removing the material for taking credit complete all as specified and as directed. Make : CG Cat part no. 18 W XP CFL 6500 or equivalent in Make: Bajaj/Wipro/Philips as approved by AGE (I)
Supply & Replace PLC 18 watts Holder including taking down old unserviceable holder and removing the material for taking credit complete all as specified and as directed. Make: Bajaj/Wipro/Philips/CG as approved by AGE (I)
Supply & Replace PLC 2 x 18 watts Electronic Choke. including taking down old unserviceable choke and removing the material for taking credit complete all as specified and as directed. Make: Bajaj/Wipro/Philips/CG as approved by AGE (I).
Supply & Replace PLC lamp 11 watts 2 pin or 4 pin including taking down old unserviceable lamp and removing the material for taking credit complete all as specified and as directed. Make : CG Cat part no. 11 W XP CFL 6500 or equivalent in Bajaj/Wipro/Philips as approved by AGE (I)
Supply & Replace PLC 11 watts Holder including taking down old unserviceable holder and removing the material for taking credit complete all as specified and as directed.
Supply & Replace PLC 11 watts Electronic Choke. including taking down old unserviceable choke and removing the material for taking credit complete all as specified and as directed. Make: Bajaj/Wipro/Philips/CG as approved by AGE (I)
Supply and fix Fluroscent Tube Light 28 Watts including taking down old unserviceable FTL and removing the material for taking credit complete all as specified and as directed. Make: Bajaj/Wipro/Philips/CG as approved by AGE (I)
Supply and fix Electronic Ballast 36 watts /40Watts including taking down old unserviceable ballast and removing the material for taking credit complete all as specified and as directed.
Supply and fix Electronic Ballast 28 Watts including taking down old unserviceable ballast and removing the material for taking credit complete all as specified and as directed.
Supply and fix starter 28 / 36 /40 W including taking down old unserviceable starter and removing the material for taking credit complete all as specified and as directed.
Supply and fix Bi-pin holder including taking down old unserviceable holder and removing the material for taking credit complete all as specified and as directed.
Supply and fix Starter Holder including taking down old unserviceable holder and removing the material for taking credit complete all as specified and as directed.
Supply and fixing of 20 watts CFL lamps direct fit all as directed as required at site including dismantling old unserviceable lamp and removing the taken down material for taking credit complete all as specified and as directed. Make: Bajaj/Wipro/Philips/CG as approved by AGE (I)
Supply and replace 24 W Flexible LED strip IP65 of 5 meter long with driver ,6500 K including taking down old unserviceable light complete all as specified and as directed. . Make: Philips Cat Part No.SKYCove 5M WW or equivalent in Bajaj/Wipro/CG as approved by AGE (I)
Taking down carefully old unserviceable submain wiring with aluminum conductor cable 4/6/10/16 Sqmm in PVC conduit complete removing the materials and taken as credit and making good the disturbed surface of wall / floor etc... complete all as specified and as directed.
Sub main wiring with two run single core 4 sqmm multi stranded copper conductor PVC insulated unsheathed cable 1100 volts grade and one run of 4 sqmm multi stranded copper conductor cable as earth continuity conductor drawn into and including non-metallic rigid PVC conduit 25 mm dia/PVC casing capping 25 mm including conduit accessories all as specified and directed. Note: Three runs of 4 Sqmm cable, one run of 4 sqmm earth conductor and one run of 25mm conduit / casing capping will be measured as one unit length.
Sub main wiring with two run single core 6 sqmm multi stranded copper conductor PVC insulated unsheathed cable 1100 volts grade and one run of 6 sq mm multi stranded copper conductor cable as earth continuity conductor drawn into and including non-metallic rigid PVC conduit 32 mm dia/PVC casing capping 25 mm including conduit accessories all as specified and directed. Note: Two runs of 6 Sqmm cable, one run of 6 sqmm earth conductor and one run of conduit / casing capping will be measured as one unit length.
Sub main wiring with four runs single core 4sqmm multi stranded copper conductor PVC insulated unsheathed cable 1100 volts grade and two runs of 4 sqmm multi stranded copper conductor cable as earth continuity conductor drawn into and including non-metalic rigid PVC conduit, 25mm dia/PVC casing caping 32 mm and conduit accessories concealed/surface of wall/roof/ceiling etc complete all as specified and directed. Note: Four runs of 4 sqmm and two runs of 4 sqmm cable and one run of 25mm dia conduit/casing capping shall be measured as one unit length.
Sub main wiring with four runs single core 6 sqmm multi stranded copper conductor PVC insulated unsheathed cable 1100 volts grade and one run of 6 sqmm multi stranded copper conductor cable as earth continuity conductor drawn into and including non-metallic rigid PVC conduit 32 mm dia/PVC casing capping 32 mm including conduit accessories all as specified and directed. Note: four runs of 6 Sqmm cable, one run of 6 sqmm earth conductor and one run of 32 mm conduit / casing capping will be measured as one unit length.
Sub main wiring with four runs single core 10 sqmm multi stranded copper conductor PVC insulated unsheathed cable 1100 volts grade and one run of 10 sqmm multi stranded copper conductor cable as earth continuity conductor drawn into and including non-metallic rigid PVC conduit 32 mm dia/PVC casing capping 32 mm including conduit accessories all as specified and directed. Note: four runs of 10 Sqmm cable, one run of 10 sqmm earth conductor and one run of 32 mm conduit / casing capping will be measured as one unit length.
Sub main wiring with four runs single core 16 sqmm multi stranded copper conductor PVC insulated unsheathed cable 1100 volts grade and one run of 16 sqmm multi stranded copper conductor cable as earth continuity conductor drawn into and including non-metallic rigid PVC conduit 40 mm dia/PVC casing capping 32 mm including conduit accessories all as specified and directed. Note: four runs of 16 Sqmm cable, one run of 16 sqmm earth conductor and one run of 40 mm conduit / casing capping will be measured as one unit length.
Supply and fix Sheet metal enclousers with socket plug top and MCB SPN 20Amps, 240 volts, with a two pin and earth plug socket complete with one single MCB 20 Amps, 240 volts (for AC ) including taking down old unserviceable old unserviceable Sheet metal enclousers with socket plug top complete all as specified and directed.
Supply and fix sheet metal enclosure powder coated double door for Distribution Board, SPN 4 way DB with Degree of Protection IP 42 , Detachable Gland Plate, Box Insertion Marks ,Circuit Identification Label, Neutral Link ,Earth Link , Tin Plated Copper Bus Bar including , Disconnecting electric connections, dismantling from position unserviceable DBs for taking into credit complete all as specified and as directed.
Supply and fix sheet metal enclosure powder coated double door for Distribution Board, SPN 8 way DB with Degree of Protection IP 42 , Detachable Gland Plate, Box Insertion Marks,Circuit Identification Label, Neutral Link ,Earth Link , Tin Plated Copper Bus Bar including , Disconnecting electric connections, dismantling from position unserviceable DBs for taking into credit complete all as specified and as directed.
Supply and fix sheet metal enclosure powder coated double door for Distribution Board, SPN 12 way DB with Degree of Protection IP 42 , Detachable Gland Plate, Box Insertion Marks ,Circuit Identification Label ,Neutral Link ,Earth Link , Tin Plated Copper Bus Bar including , Disconnecting electric connections, dismantling from position unserviceable DBs complete for taking into credit all as specified and as directed.
Supply and fix sheet metal enclosure powder coated double door for Distribution Board, TPN 4 way DB with Degree of Protection IP 42 , Detachable Gland Plate, Box Insertion Marks ,Circuit Identification Label ,Neutral Link ,Earth Link , Tin Plated Copper Bus Bar including , Disconnecting electric connections, dismantling from position unserviceable DBs complete for taking into credit all as specified and as directed.
Supply and fix sheet metal enclosure powder coated double door for Distribution Board, TPN 8 way DB with Degree of Protection IP 42 , Detachable Gland Plate, Box Insertion Marks ,Circuit Identification Label ,Neutral Link ,Earth Link , Tin Plated Copper Bus Bar including , Disconnecting electric connections, dismantling from position unserviceable DBs complete for taking into credit all as specified and as directed.
Supply and fix sheet metal enclosure powder coated double door for Distribution Board, TPN 12 way DB with Degree of Protection IP 42 , Detachable Gland Plate, Box Insertion Marks,Circuit Identification Label,Neutral Link ,Earth Link , Tin Plated Copper Bus Bar including , Disconnecting electric connections, dismantling from position unserviceable DBs complete for taking into credit all as specified and as directed.
Supply and fix sheet metal enclosure powder coated double door for Distribution Board, VTPN 4 way DB including , Disconnecting electric connections, dismantling from position unserviceable DBs for taking into credit complete all as specified and as directed.
Supply and fix sheet metal enclosure powder coated double door for Distribution Board, VTPN 6 way DB including , Disconnecting electric connections, dismantling from position unserviceable DBs for taking into credit complete all as specified and as directed.
Supply and fix sheet metal enclosure powder coated double door for Distribution Board, VTPN 8 way DB including , Disconnecting electric connections, dismantling from position unserviceable DBs for taking into credit complete all as specified and as directed.
Supply and fix sheet metal enclosure powder coated double door for Distribution Board, VTPN 12 way DB including , Disconnecting electric connections, dismantling from position unserviceable DBs for taking into credit complete all as specified and as directed.
Supply and fix MCB SP 5 A to 32 A , B curve including , Disconnecting electric connections, dismantling from position unserviceable MCB for taking into credit complete all as specified and as directed.
Supply and fix MCB SP 40 Amps , B curve including , Disconnecting electric connections, dismantling from position unserviceable MCB for taking into credit complete all as specified and as directed.
Supply and fix MCB SPN 32 Amps , B curve including , Disconnecting electric connections, dismantling from position unserviceable MCB for taking into credit complete all as specified and as directed.
Supply and fix MCB SPN 40 Amps , B curve including , Disconnecting electric connections, dismantling from position unserviceable MCB for taking into credit complete all as specified and as directed.
Supply and fix MCB SPN 50A / 63 A , B curve including , Disconnecting electric connections, dismantling from position unserviceable MCB for taking into credit complete all as specified and as directed.
Supply and fix MCB TP 40A , C curve including , Disconnecting electric connections, dismantling from position unserviceable MCB for taking into credit complete all as specified and as directed.
Supply and fix MCB TP 50A / 63 A , C curve including , Disconnecting electric connections, dismantling from position unserviceable MCB for taking into credit complete all as specified and as directed.
Supply and fix MCB TPN 40 Amps , C curve including , Disconnecting electric connections, dismantling from position unserviceable MCB for taking into credit complete all as specified and as directed.
Supply and fix MCB TPN 50 A / 63 A , C curve including ,Disconnecting electric connections, dismantling from position unserviceable MCB for taking into credit complete all as specified and as directed.
Supply & replace Isolator Four Pole 40 Amps including , Disconnecting electric connections, dismantling from position unserviceable Isolator for taking into credit complete all as specified and as directed.
Supply & Replace Isolator Four Pole, 50 A/ 63A including , Disconnecting electric connections, dismantling from position unserviceable Isolator for taking into credit complete all as specified and as directed.
Supply & Replace Isolator Four Pole, 100A including , Disconnecting electric connections, dismantling from position unserviceable Isolator for taking into credit complete all as specified and as directed.
Taking down carefully unserviceable ceiling fans of any size from its position, dismantling blade, opening the fan motor, removing the burnt grease, applying new bearing grease, removing of defective parts such as ball bearing, bush bearing, burnt winding, shaft, split pin, condenser, condenser holder, shackle etc. reassembling after replacement of defective parts including replacement of 3 core 0.75 Sqmm (24/0.2mm) flexible copper cable from ceiling rose to connector, hanging in its position properly complete all as specified and directed. Note:- Replacement of unserviceable spare parts shall be measured and paid separately under respective items of this schedule here-in-after as supply only.
Description all as per Sl item No. 205 but for exhaust fan of any size
Description all as per Sl item No 205 but wall mounted fan of any size.
Description all as per Sl item No 205 but fresh air fan of any size.
Supply only ball bearing of existing size suitable for ceiling fan, exhaust fan, fresh air fan, pedestal fan as that of existing defective one complete all as specified and directed. Make : Tata/SKF
Supply only bush bearing of existing size suitable for ceiling fan, exhaust fan, fresh air fan and pedestal fan of complete all as specified and directed.
Supply only condenser 2.5 MFD complete all as specified and directed. Make : Usha/Keltron/Uptron
Supply only condenser 4 MFD complete all as specified and directed. Make : Usha/Keltron/Uptron
Supply only condenser holder/clamp PVC or metal for fixing capacitor/condenser complete all as specified and directed.
Supply only shackle accessories to hold with fan hook complete with rubber bush, bolt, nut, split pin complete all as specified and directed.
Supply and fix canopy suitable for ceiling fans of size 48"/56" all as per existing type and model & Colour of fan at site including dismantling the old ones complete all as specified and directed.
Material and labour for cleaning and preparing the surfaces of ceiling fan, removing the grease, carbon dust over the fans and painting with one coat of synthetic enamel paint of approved colour with brush painting and writing MES number on the fan complete all as specified and directed.
Material and labour for cleaning and preparing the surfaces of exhaust fan removing the grease, carbon dust over the fans and painting with one coat of synthetic enamel paint of approved colour with brush painting and writing MES number on the fan complete all as specified and directed.
Material and labour for cleaning and preparing the surfaces of pedestal fan, removing the grease, carbon dust over the fans and painting with one coat of synthetic enamel paint of approved colour with brush painting and writing MES number on the fan complete all as specified and directed.
Material and labour for cleaning and preparing the surfaces of fresh air fan, removing the grease, carbon dust over the fans and painting with one coat of synthetic enamel paint of approved colour with brush painting and writing MES number on the fan complete all as specified and directed.
Rewinding the stator complete with super enamelled bare copper conductor with the existing size/gauge and number of turns as that of the old one, insulating, varnishing and pre heating for ceiling fan 1200mm/1400mm sweep complete all as specified and directed.
Description all as per Sl Item No. No 220 here-in-before but Exhaust fan upto 300mm sweep.
Description all as per Sl Item No. No 220 here-in-before but Exhaust fan above 300mm upto 450mm sweep.
Description all as per Sl Item No. No 220 here-in-before but Wall mounted fan upto 300mm sweep.
Description all as per Sl Item No. No 220 here-in-before but Pedestal fan up to 400mm sweep.
Description all as per Sl Item No. No 220 here-in-before but fresh air fan up to 200mm sweep.
Removing the damaged and corroded exhaust fan louvers and replace with new louvers of size up to 300mm sweep complete all as specified and directed.
Removing the damaged and corroded exhaust fan louvers and replace with new louvers of size above 300mm and up to 450mm complete all as specified and directed.
Removing the damaged and corroded exhaust fan blades and replace with new blades of size up to 300mm sweep complete all as specified and directed.
Removing the damaged and corroded exhaust fan blades and replace with new blades of size above 300mm and up to 450mm complete all as specified and directed.
Taking down defective storage water heater of any capacity from buildings after disconnecting carefully water and electric connection, opening the bottom cover replacing the defective parts fixing the cover and refixing in original position reconnecting both water and electric connection and testing complete all as specified and directed. Notes :- Replacement of spares will be measured and paid for separately under respective items of the schedule here-in-after as supply only.
Supply only new heating element of capacity 1.5KW with rubber gasket complete all as specified and directed.
Supply only new heating element of capacity 2 KW with rubber gasket complete all as specified and directed.
Supply only thermostat suitable for storage type water heater complete all as specified and directed.
Supply only Pressure release valve 15mm dia suitable for geyser complete all as specified and directed.
Supply only Air release valve 15mm dia suitable for geyser complete all as specified and directed.
Supply only 3 core 2.5 Sqmm copper conductor cable suitable for geysers of any size complete all as specified and directed.
Supply only Non return valve 15mm dia suitable for geyser complete all as specified and directed.
Supply and fix Metal socket single pole and neutral with two pin and earth socket complete with one single pole MCB 25 Amps complete all as specified and directed. Make : L&T/Legrand/ ABB/ Siemens/ Schneider
Supply and fix 3 pin plug top suitable for metal socket of capacity 25 Amps complete all as specified and directed. Make : Anchor/Plaza
Material and labour preparing external surfaces of water heater, cleaning and painting with one coat of synthetic enamel paint of white colour of approved make with brush and writing MES No. complete all as specified and directed.
Supply only Apparatus plate assembly suitable to fix thermostate, heating elements as of geyser including nuts etc... complete all as specified and directed.
Supply only Fusible plug complete all as specified and directed.
Removing the copper tank from the geyser, brazing to arrest the leakage, reassembling and refixing complete all as specified and directed.
Supply only Bottom inspection chamber cover suitable for 25 Ltrs capacity geyser of any make/model complete all as specified and directed.
Supply only Indication lamp suitable for geyser in round/rectangular shape complete all as specified and directed.
Supply and replace 3 pin plug 15 Amps capacity complete all as specified and directed. Make : Anchor/Plaza
Supply only geyser tank of capacity 15 Ltrs made out of stainless steel complete all as specified and directed.
Supply only geyser tank of capacity 25 Ltrs made out of stainless steel complete all as specified and directed.
Removing the old unserviceable hook fan from its position without damaging ceiling and supply and fix new fan hook in the ceiling and packing it strongly using necessary packing material and ensuring the strength of joint can withhold the weight of ceiling fan, complete all as specified and directed.
Supply only Down rod of size 2 feet to 3 feet for fix ceiling fan complete all as specified and directed.
Supply only Down rod of size 4 feet to 6 feet for fix ceiling fan complete all as specified and directed.
Replacement of PCB Card of Servo Voltage Stabilizer 75 KVA 3 phase complete all as specified and directed.
Annual Maintenance for 10 KVA 3 Phase output, online UPS including quarterly visit from authorised service centers, complete all as specified and directed.
Removing old unserviceable down rod of any size from the ceiling and carefully taking down the ceiling fan & keeping it in safe custody and fixing new down rod and reassemble the ceiling fan in its position and testing for smooth operation, complete all as specified and directed. Note: Ceiling rod shall be measured and paid separately.
Fixing only wall mounted LED batten 4 feet of capacity 20W including taking down old fitting complete all as specified and directed.
Fixing only LED light fitting 2 feet,10 W including taking down old fitting complete all as specified and directed.
Fixing only Recessed mounting 2 ft x 2 ft LED luminaire 36W or nearest higher wattage including taking down old fitting complete all as specified and directed.
Fixing only switch piano flush type single pole one way 5 A 240 Volts including taking down old unserviceable switches complete all as specified and as directed
Fixing only switch Socket combination 2 in 1, 5 Amps Flush type 240 Volts including taking down old unserviceable one complete all as specified and as directed.
Fixing only switch Socket combination 5 Amps / 16 amps, 5 in 1 flush type 240 Volts including taking down old unserviceable one complete all as specified and as directed.
Fixing only Stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc including taking down old unserviceable one complete all as specified and as directed. Note for Sl item Nos. 248 to 254: These items will be issued under Schedule "B" stores free for fixing.
Taking down old unserviceable old damaged GI pipe and supply and fix new GI pipe light grade of size 50 mm dia for protection of UG cable on walls/under floors/road crossings/in trenches complete all as specified and as directed Make : Tata/Zindal/Zenith/Swastik/Prakash
Description all as per Sl item No. 255 here-in-before but for GI pipe of 80 mm dia bore, medium grade
Description all as per Sl item No. 255 here-in-before but for GI pipe of 100 mm dia bore, medium grade
Supply and lay in trenches, fixed to wall / pole/ tray etc... UG cable XLPE insulated armoured, heavy duty, with aluminum conductor 1100 volts grade of cross sectional area of following size all as specified and as directed.
2 core 10 Sqmm
4 Core 16 Sqmm
2 core 16 Sqmm
3 .5 Core 25 Sqmm
3 .5 Core 50 Sqmm
3 .5 Core 70 Sqmm
3 .5 Core 95 Sqmm
3 .5 Core 120 Sqmm
3.5 Core 150 Sqmm
3.5 Core 185 Sqmm
Laying only in trenches, fixed to wall / pole/ tray etc... UG cable XLPE insulated armoured, heavy duty, with aluminum conductor 1100 volts grade of cross sectional area of following size all as specified and as directed. Note:These items will be issued under "Schedule B" stores free for fixing
2 core 10 Sqmm
4 Core 16 Sqmm
2 core 16 Sqmm
3 .5 Core 25 Sqmm
3 .5 Core 50 Sqmm
3 .5 Core 70 Sqmm
3 .5 Core 95 Sqmm
3 .5 Core 120 Sqmm
3.5 Core 150 Sqmm
3.5 Core 185 Sqmm
Disconnecting and taking out from trenches / poles, out lived LT UG cable of various sizes as mentioned under Sl Item Nos. 258 and 259 here-in-before and taking old unserviceable LT UG into credit complete all as specified and as directed . Note : Excavation and earth work will be measured and paid separately.
Material and labour for earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below GL) with top edge of earth plate not less than 1.5 Mtr below normal ground level, earth plate surrounded from all sides by 15cm thick and packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by using galvanized iron strip 32 x 6 mm as earthing lead connected by means of bolts, nuts, check nuts and washer of galvanized iron or steel, provision of 40 mm dia GI pipe medium grade for protection of GI strip upto 7.5 meter long and 20mm dia GI pipe medium grade for watering arrangement and PCC (1:3:6) , type C1 chamber, GI funnel, wire gauge, 50 mm thick RCC 1:2:4, type B1 earth pit cover with 6 Nos, 8 mm dia high strength deformed steel TMT bars on both ways including necessary excavation in any type of soil, returning, filling in, removal of surplus soil to distance not exceeding 50 metre, provision of charcoal and salt complete all as shown in electrical plate No 3 of schedule Part-I complete all as specified and directed. Note : Earth continuity conductor and GI protection pipe beyond 7.5 meters shall be measured and paid under the respective items
Supply and lay earth continuity conductor or main earthing lead fixed to wall on batten or recess or burried in ground or drawn in conduit / conduit pipe or fixed to poles or any other indicted situation for loop earthing etc... of galvanised steel earth strip of size 32 X 6 mm including taking down old unserviceable earth strip complete for taking into credit complete all as specified and as directed
Material and labour for earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below GL) with top edge of earth plate not less than 1.5 Mtr below normal ground level, earth plate surrounded from all sides by 15cm thick and packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by using galvanized steel earth wire 4 mm dia as earthing lead connected by means of bolts, nuts, check nuts and washer of galvanized iron or steel, provision of 40 mm dia GI pipe medium grade for protection of GI strip upto 7.5 meter long and 20mm dia GI pipe medium grade for watering arrangement and PCC (1:3:6) , type C1 chamber, GI funnel, wire gauge, 50 mm thick RCC 1:2:4, type B1 earth pit cover with 6 Nos, 8 mm dia high strength deformed steel TMT bars on both ways including necessary excavation in any type of soil, returning, filling in, removal of surplus soil to distance not exceeding 50 metre, provision of charcoal and salt complete all as shown in electrical plate No 3 of schedule Part-I complete all as specified and directed. Note : Earth continuity conductor and GI protection pipe beyond 7.5 meters shall be measured and paid under the respective items
Supply and lay earth continuity conductor or main earting lead fixed to wall on batten or recess or burried in ground or drawn in conduit / conduit pipe or fixed to poles or any other indicted situation for loop earthing etc of galvanised steel earth wire 4 mm dia including taking down old unserviceable GI earth wire complete all as specified and as directed.
Supply and lay earth continuity conductor or main earting lead fixed to wall on batten or recess or burried in ground or drawn in conduit / conduit pipe or fixed to poles or any other indicted situation for loop earthing etc of galvanised copper earth strip of size 20 X 3.15 mm including taking down old unserviceable strip complete for taking into credit complete all as specified and as directed
Supply and fix Lightning Protection Single point air termination aluminum rod 12mm dia 300mm long with base plate including taking down old unserviceable aluminium rod for taking into credit complete all as specified and as directed
Test point terminal box made out of Gun metal or Phosphorous bronze of size 75 x 75 x 25 mm drilled and screwed including 3 Nos. 8mm dia 25mm long hexagonal head screws including taking down old unserviceable test point terminal box for taking into credit complete all as specified and as directed
Supply and fix Aluminium strip of 25 x 3.15 mm fixed with screws/ clamps / insulators for roof conductors and down conductors above ground level including taking down old unserviceable Aluminium strip for taking into credit complete all as specified and as directed
Material and labour for Pin type, porcelain ,virteous, white, brown or green insulator including one galvanised mild steel, spindle, two galvanised iron washers and one galvanised iron nut, 50 mm height, 65 mm dia, for 550 volts grade, including taking down old unserviceableinsulator for taking into credit complete all as specified and as directed
Surface dressing in soft/loose soil and not exceeding 15 cm and getting out including removing grass and vegetation growth in sub station surrounding around LT out door panel , double pole structure and wherever required complete all as specified and directed.
Site clearence in soft/ loose soil in and around the sub station and pump area, as and when required complete all as specified and directed.
Supply and fix in repair MCCB four pole 415 volts 50 Hz , 160 amps, with rupturing capacity 36 KA complete all as specified and as directed including taking down old unserviceable MCCB for taking into credit complete all as specified and as directed Make : ABB/L&T/Legrand/Siemens/Schneider
Supply and fix in repair MCCB four pole 415 volts 50 Hz , 200 amps, with rupturing capacity 36 KA complete all as specified and as directed including taking down old unserviceable MCCB for taking into credit complete all as specified and as directed Make : ABB/L&T/Legrand/Siemens/Schneider
Supply and fix in repair MCCB four pole 415 volts 50 Hz , 250 amps, with rupturing capacity 36 KA complete all as specified and as directed including taking down old unserviceable MCCB for taking into credit complete all as specified and as directed Make : ABB/L&T/Legrand/Siemens/Schneider
Supply and fix in repair MCCB four pole 415 volts 50 Hz , 400 amps, with rupturing capacity 36 KA complete all as specified and as directed including taking down old unserviceable MCCB for taking into credit complete all as specified and as directed Make : ABB/L&T/Legrand/Siemens/Schneider
Fixing only MCCB three pole/Four Pole 415 volts 50 Hz , 63 amps, complete all as specified and as directed including taking down old unserviceable MCCB for taking into credit complete all as specified and as directed Make : ABB/L&T/Legrand/Siemens/Schneider
Fixing only MCCB three pole/Four Pole 415 volts 50 Hz , 100 amps, complete all as specified and as directed including taking down old unserviceable MCCB for taking into credit complete all as specified and as directed. Make : ABB/L&T/Legrand/Siemens/Schneider
Fixing only MCCB three pole/Four Pole 415 volts 50 Hz , 160 amps, complete all as specified and as directed including taking down old unserviceable MCCB for taking into credit complete all as specified and as directed. Make : ABB/L&T/Legrand/Siemens/Schneider
Fixing only MCCB three pole/Four Pole 415 volts 50 Hz , 200 amps,complete all as specified and as directed including taking down old unserviceable MCCB for taking into credit complete all as specified and as directed. Make : ABB/L&T/Legrand/Siemens/Schneider
Fixing only MCCB three pole/Four Pole 415 volts 50 Hz , 250 amps, complete all as specified and as directed including taking down old unserviceable MCCB for taking into credit complete all as specified and as directed. Make : ABB/L&T/Legrand/Siemens/Schneider Note for Sl item Nos. 276 to 280: These items will be issued under Schedule "B" stores free for fixing.
Painting the Panel boards/DB Boxes/covers/DG Set/Accoustic Enclosures as required at site after scraping out completely the old paint with one coat of red oxide primer and two coats of synthetic enammel paint including carrying out minor welding works, if required, complete all as specified and as directed Note : Colour/tint of paint shall be decided by the Engineer-in-charge.
Material and labour for plain cement concrete for foundation, filling and mass concrete of type C1 (1:3:6) using 20 mm graded aggregate complete all as specified and as directed .
Supply & fixing pole mounting junction box (looping box) for street light with outside dimension 230 x 170 x 105 mm comprising of PVC connector and one MCB SP 6 amps including mounting arrangement complete all as specified and as directed . Make: Sintex/Hansel/Spelsbary
Material and labour for straight through joint (epoxy) for underground cable including joint kit for making joint suitable for aluminium conductor cable of size :- Make : Raychems/Densons/M-Seal/Birla-3M/Yamuna gases & chemicals Note :- Excavation, returning filling in removing, sand cushioning, brick etc shall be measured and paid separately under respective items of work.
2 core 16 to 35 sqmm or 3 core 16 to 25 sqmm or 4 core 10 to 16 sqmm
3 ½ core / 4 core 25 to 35 sqmm
3 ½ core 50/70 sqmm
3 ½ core 95/185 sqmm
3 ½ core 240 sqmm
3 ½ core 300 sqmm
Supply and replace ON Load Change over switch 415V in shet metal enclosures 4 pole 100 Amps including taking down old unserviceable ON Load Change over switch for taking into credit complete all as specified and as directed .
Supply and fix in repair ON Load Change over switch 415V in shet metal enclosures 4 pole 200 Amps including taking down old unserviceable ON Load Change over switch for taking into credit complete all as specified and as directed .
Supply and fix in repair ON Load Change over switch 415V in shet metal enclosures 4 pole 250 Amps including taking down old unserviceable ON Load Change over switch for taking into credit complete all as specified and as directed .
Supply and fix in repair ON Load Change over switch 415V in shet metal enclosures 4 pole 400 Amps including taking down old unserviceable ON Load Change over switch for taking into credit complete all as specified and as directed .
Supply and fix new GI bracket made out of 40 mm dia GI pipe length 1.20 metre long bent to an angle of 135 degree and reduced at the end to 32 mm dia to match with the street light including suitable 02 set of clamps with nut ,bolts ,and washer for fixing of light to pole, all as specified and directed including removing corroded GI Bracket along with clamps, bolts, nuts etc... from pole for taking into credit complete all as specified and as directed .
Material and labour for Drilling (horizontally) under the road or concrete for insertion of pipe to facilitate cable connection/water pipe connection etc... the dia of bore is maximum 100 mm along with the protection pipe of GI pipe from 25mm to 100mm dia complete all as specified and directed . Note:- GI Pipe, light grade shall be measured and paid seperately.
Material and labour for Writing letters (Block.Roman, Italic or Indian) with thick synthetic enamel paint , to stand out boldly and solidly without showing signs of brush marks, if necessary, repainted until the desired result is obtained , 10 to 15 cm height and painting with contrasting colour in the background of letter complete all as specified and directed. Note : Colour/Tint of paint shall be decided by the Engg-in-charge.
Taking out old battery of solar lights, servicing of battery and draining out diluted electrolite and provisioning of electrolyte of desired density and specific garvity including initial charging of the battery for 72 Hrs and refixing in position complete all as specified and directed.
Supply and fix danger notice plate made of 1.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones painted with synthetic enamel paint in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 200 x 150 mm size, complete all as specified and as directed
Supply and fix lugs of size 10 to 25 Sqmm complete all as specified and as directed
Supply and fix lugs of size 35 to 50 Sqmm complete all as specified and as directed
Supply and fix lugs of size 70 to 95 Sqmm complete all as specified and as directed
Supply and fix lugs of size 120 to 185 Sqmm complete all as specified and as directed
PSK Enterprises
DPS sales and services india
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .