AE/BESD-II
OFFICE OF THE ASSISTANT ENGINEER Bankura Electrical Sub-Division-II, PWDte Kenduadihi PWD campus near Bhirabsthan Bankura-722102
Upkeepment and Maintenance of Electrical Installation (Regular/Periodical Maintenance as well as Preventive and Corrective Maintenance) including AC Machine, Mortuary cooler, Fire Alarm and Detection system at Khatra Sub-Divisional Hospital, Bankura.
2024_WBPWD_747510_1
WBPWDTE/AE/BESD-II/e-NIQ 03 of 2024-25
Open Tender
ELECTRICAL WORKS ORG
Item Rate
30 days
Khatra Sub-Divisional Hospital
Please refer Tender documents.
5 documents required · 5 mandatory
₹12,000
Yes
14 Nov 2024
9 Sept 2024
20 Sept 2024
9 Sept 2024
18 Sept 2024
9 Sept 2024
Amount
Supply and Installation of 1.5 Ton capacity Rotary Compressor in replacement of the damage machine and Re-fitting the same in position as per direction of EIC. Blood Centre--2nos (Voltas make) Rogi Kalyan Samiti--1nos (Haier make)
Supply and Fixing of new 60/130 watt,1200 RPM Fan Motor of Outdoor unit of existing 1.5 Ton Split type AC machine after taken out the old one from the machine and Re-fitting the same in position as per direction of EIC. HDU--1nos (Hitachi make) Blood Centre--2nos (Haier & Voltas make) Doctors Room--1nos (LG make)
Supply and Fixing of new 30 watt Fan Motor of Indoor unit of existing 1.5 Ton Split type AC machine after taken out the old one from the machine and Re-fitting the same in position as per direction of EIC. HDU--1nos (Hitachi make) IPD Doctors Room--1nos (Haier make)
Supply and Fixing of new 125 watt, 940 RPM Fan Motor of existing 1.5 Ton Window type AC machine (Carrier make) after taken out the old one from the machine and Re-fitting the same in position as per direction of EIC. OPD--2nos (Carrier make)
Repairing of the PCB unit of the Indoor unit of existing 1.5 Ton Split type AC machine. Office Room--1nos (Hitachi make)
Dismentling the total system of split type AC machine with damage ruber/fome insulation wittbinding materials etc. and re-fitting the same after through checking by Co's own special tools & tackles including labour as per direction of EIC
Supply and Fixing internal adhesive foam preventing sweating on the surface and maintang proper cooling. 5/8'' dia 6mm thick Nitrel Foam
1/4'' dia 6mm thick Nitrel Foam
Tie lock (pvc type) for proper fixing the above pipe insulation with necessary other materials and scaffolding etc. as required as per direction of EIC
Supply and Fixing 40/45 MFD ,P2 type brust proof Running Capacitor for Split/Window type AC machine. (Make-Tubcon/Universal)
Supply and Fixing 4/6/10 MFD ,P2 type brust proof Running Capacitor for Split/Window type AC machine. (Make-Tubcon/Universal)
Supply and Fixing the outdoor clamp for condenser made of Aluminium with galvanized coat 2''x5'' incl. necy. Screw etc. by Co's own tools & tackels including labour as per direction of EIC.
Cost for charging the Refrigerant R-22/32 Gas
Supply and Fixing Fan Motor blade of outdoor unit. IPD Doctors Room--1nos (Haier make) Iso Doctors Room--1nos (LG make)
Supply and Fixing of 20''x31'' copper made condensing coil (3/8)'' and Over oiling , grising the blower motor ,S/Changing strainer /Capailary set as required as per direction of EIC Blood Centre--2nos (Voltas make)
Supply & Delivery of fixed speed Room Air Conditioner fitted with rotary compressor and copper condensing and cooling coil having following major specification. Refrigerent-R410A/R32,Capacitor Type:P2 Minimum cooling capacity (kw):5.2 or higher Maximum power consumption:1450 watts or less EER star rating:3.59 (2 Star/2023) or higher as recent year manufacture Minimum tonnage required 1.5 TR or higher with other modern features.Minimum Room discharge Air flow (CFM):500 or higher & energy efficient type,with approved make as per IS 1391,Part-I,with remote and all the necessary connection etc. asdirection of EIC. Make: (Mitsubishi Heavy Industries/Mitsubishi Electric/O-General/Hitachi or as per direction of EIC
Installation of the Split type 1.5 Ton /2.0 Ton A.C machine incl cutting of wall etc incl S & F suitable sizes Copper pipe of same make for Suction & Liquied line with insulation incl. S & F drain pipe of reqd. length to comp. the instn and mending good the damages as per direction of EIC.
S & F laying of- (i) gauge copper pipe 5/8" 0.7 mm thick for suction (ii) copper pipe 1/4" 0.6 mm thick for discharge (OEM make) with 9 mm thick thermal insulation foam nitrile / rubber / K Flex / Accroflex with max saddling with max 1 mtr distance both for suction & discharge pipe and mending good the holes & damages as directed by EIC. (extra length for distance of ODU & IDU exceed 3mtr.)
S & Laying 3 core 2.5 sqmm PVC insulated & unarmoured copper wire (make--Gloster/Mescab/Havells/KEI) for 1.5/2 Tr. Split AC machine (extra length for distance of ODU & IDU exceed 3 mtr.) with max saddling with max 1 mtr distance as per direction of EIC.
S & F of flexible PVC high quality water carrying pipe of 25 mm dia/proper size for drainage the condensate water from already installed AC to any available (nearest) drain water pipe or near to ground level and the pipe must be properly saddled with the wall incl. proper insertion of the flexible pipe to drain water pipe and sealing the entry with required materials like PVC tape, High quality sealing the entry with required materials like PVC tape, high quality sealing gum etc. as reqd. All these arrangement for fixing must be arranged by the agency itself as per direction of EIC.
Supplying and fixing of 250 V AC timers fixed on wall with flat iron frame as per direction of EIC and the Box shuld be comprising with the following accessorise --- i) Double-door SPN MCB Distribution Board with IP-42/43 protection 10 / 12 way Enclosureas reqd . ( Make - Legrand / L & T ) – 1 no ii) 230 V , 50 Hz ,16 Amp Single dial 1 x 24 Hrs.Timer ( Microrex QT31 ) of quartz driven running reserve Day dial back up by nickle cadmium battery (Make - GEC / Legrand ) – 1 no iii) 250 V, 50 Hz , 40 Amp DP Conctractor with ( 2 NO or 1 NO + 1 NC Aux. Contract ) ( Make - Legrand / L & T ) – 1 no iv) 250 V, 50 HZ , 40 Amp , DP MCB Isolator ( Make - Legrand / L & T ) – 1 no v) Auto / Manual By pass Toggle Switch arrangement – 1 no. vi) 250 V , Diode type neon Indicator lamp ( Make - Legrand / L & T ) – 1 no vii) Bakelite base with FP bolt type stud / Terminal block incl S & F Neutral Bar etc with this box for termination of power . viii) The complete arrangement must be wiring by 2.5 Sq mm PVC insulated Cu wire with suitable length incl socketing /lugs etc as per requirement & direction of EIC (Make - Legrand /L & T / Crabtree ) Pathology Lab--1nos OT Doctors Room--1nos
S & F 240V 25A OLP - 30 Electrronic motor starter in 175mm X 100mm X 65 mm depth 16 SWG MS Box coneled in wall with bakelite top cover incl. Necy. Conncetion as per direction of EIC Pathology Lab--1nos
ANIKET COOLING AND REFRIGERATION CO (BID ID -5565244)
ROY REFRIGERATION (BID ID -5565532)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .