Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.3 LAccepted-AOC | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹33.6 L+₹1.3 L (4.16%)Rejected-Finance 159 SHIV NAGAR MODIPURAM MEERUT 250 110 UP | MEERUT | UTTAR PRADESH | 250110 | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹35.3 L+₹3.0 L (9.44%)Rejected-Finance | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹37.2 L+₹4.9 L (15.3%)Rejected-Finance 37 222 BUNDU KATRA AGRA UP | AGRA | UP | L4 | Rejected-Finance Other than lowest | |
| 5 | L5₹38.9 L+₹6.6 L (20.5%)Rejected-Finance 86 NAROTTAM KUNJ MADHU NAGAR AGRA UTTAR PRADESH 282001 | AGRA | UTTAR PRADESH | 282001 | L5 | Rejected-Finance Other than lowest |
Tender Value
₹45.5 L
EMD Value
₹91,000
Closing Date
17 Jan 2022, 6:00 pmClosed
MAJ VIJAY KUMAR SHARMA
62 STATION ROAD AGRA CANTT AGRA
PROVN OF INTEGRATED GUARD POST NEAR BUILDING NO T 05 AND PROVN OF KOTA STONE AT CERTAIN PORTION NEAR BUILDING NO T 05 UNDER GE WEST AGRA
2021_MES_495800_1
8012/848/E8
Open Tender
Civil Works
Item Rate
180 days
GE WEST AGRA
As per tender documents
9 documents required · 9 mandatory
₹500
GE WEST AGRA
₹91,000
Yes
14 Mar 2022
18 Dec 2021
21 Jan 2022
18 Dec 2021
17 Jan 2022
3 Jan 2022
Amount
Excavation in trenches in soft/ loose soil not exceeding 1.5 m wide n.exc 1.5m depth for fdn etc for shaft, wells, cesspits, man holes, pier holes etc. n.exc 10sqm on plan and n.exc 1.5m depth and getting out in soft loose soil.
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in soft soil complete all as specified and as directed.
M&L PCC 1:4:8, type D-2 (using 40mm graded crushed stone aggregate) as in foundation filling and mass concrete complete all as specified and as directed.
M&L M - 25 (design Mix) in foundations, footings, foundation beams; plinth beams; bases for columns, etc.; and mass concrete complete all as specified and as directed.
M&L M -25 (design Mix) in beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and as directed.
M&L M -25 (design Mix) in columns, pillars, piers, posts and struts complete all as specified and as directed.
M&L M -25 (design Mix) in slabs supported on walls, beams and columns in floors, roofs and in shelves and the like complete all as specified and as directed.
M&L M -25 (design Mix) in chajjas complete all as specified and as directed.
Use & waste of formwork to sides of concrete foundations, footings, bases of columns, and plinth beams; and similar work; vertical or to batter rough surface complete all as specified and as directed.
Use & waste of formwork to sides of pillars, posts, struts, piers, columns and stanchions fair surface complete all as specified and as directed.
Use & waste of formwork to sides and soffits of floor or roof beams, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc.fair finished surfaces complete all as specified and as directed.
Use & waste of formwork to chajjas and similar items including edge fair finished surfaces complete all as specified and as directed.
Use & waste of formwork to soffits of suspended slabs such as roof slabs, floor slabs and similar work; not exceeding 200mm thick (Horizontal or sloping) fair finished surfaces complete all as specified and as directed.
Use & waste of formwork to edges of rough finished surface of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide complete all as specified and as directed.
M&L Mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
M&L Mild steel TMT bars 6-8mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
M&L Mild steel TMT bars 6-10mm dia and over , cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clips as in stirrups complete all as specified and as directed.
M&L for brick work with sub-class `B' bricks, straight or curved on plan exceeding 6 M mean radius built in cement mortar (1:6) complete all as specified and as directed.
Returning filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in soft/ loose soil complete all as specified and as directed.
Removing Excavated soils not exc 50 M and depositing where directed at a level not exc1.5 M above the starting point complete all as specified and as directed.
M & L sand filling under floors or in foundation including watering and consolidation complete all as specified and as directed.
M&L100mm thick PCC 1:3:6 type C-2 (Using 40 mm graded stone aggregate) as in Floor/path/plinth protection, finished even & smooth surfaces without using extra cement complete all as specified and as directed.
M&L 50mm thick Cement concrete type B-1, 1:2:4 (using 20mm graded stone aggregate) as in floors/hard standing complete all as specified and as directed.
M&L rendering 10mm thick in cement mortar (1:4) on brick/concrete surfaces of walls,on fair faces finished even & smooth surfaces without using extra cement complete all as specified and as directed.
M&L 15mm thick rendering in cement mortar (1:6) on brick/concrete surfaces of walls other than fair faces complete all as specified and as directed.
M&L rendering 10mm thick in cement mortar (1:3) on concrete surfaces of ceiling on fair faces finished even & smooth surfaces without using extra cement complete all as specified and as directed.
M&L preparation of newly plastered or un plastered surface of wall and applying two coats of cement base paint over a coat of alkali resistant priming complete all as specified and as directed.
M&L preparation of newly plastered or un plastered surface of wall and applying two coats of oil bound distemper over a coat of putty 1mm thick complete all as specified and directed.
M&L preparation of newly plastered or un plastered surface of ceiling and applying three coats of white wash complete all as specified and as directed.
S & F Curtain rod, mild steel, chromium plated with fixing brackets, stops, rollers etc (including two nos bracket in each rod) complete all as specified and as directed.
M & L Virified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match incl screed bed on bedding layer of cement mortar(1:6) 15 mm thick complete all as specified and as directed.
S&F rolled sections (Fe-290, E-165) as in framing for cladding, glazing, door chowkats and the like fixed with angle cleats and connecting plates, etc complete all as specified and as directed.
S&F 30mm thick scond class hardwood plain, framed, panelled shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers: supplied and fitted to chowkat complete all as specified and as directed.
S&F 30mm thick, 2nd class hard wood as in glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats complete all as specified and as directed.
S&F aluminium anodized 200mm long barrel tower bolt of extruded section and fixed complete all as specified and as directed.
S&F butt hinges medium weight cold rolld mild steel of 100mm size complete all as specified and as directed.
S&F 150mm aluminium handles, cast type, anodised complete all as specified and as directed.
S&F in mild steel sliding door bolt, 300 mm plate type, stove enamelled black, with bright bolt not less than 12 mm dia with and incl a min of 6 bolts and nuts, four on bolt plate and two on staple plate complete all as specified and as directed.
S & F steel windows with side hung shutters including box type hinges with Z section steel handle, steel peg stay and hold fast, complete with glazing bars, dovetailed or welded complete all as specified and directed
S & F steel windows with side hung shutters including box type hinges with Z section steel handle steel peg stay and hold fast, complete without glazing bars, dovetailed or welded complete all as specified and directed
S&F Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and as directed.
S&F galvanised MS wire cloth 0.56mm nominal dia of wire and average width of aperture 1.18 mm and fixed with tinned tack or galvanised wire staples complete all as specified and as directed.
M&L 3mm thick ordinary quality sheet glass and glazing with oil putty in square not exc 0.5 Sqm in each panecomplete all as specified and as directed.
M&L cement concrete 1:3:6 type C-1 (using 20mm graded aggregate) as in bed blocks for fixing hold fasts etc. complete all as specified and directed.
M&L preparation of wood and wood based surfaces of any description not otherwise described over 10 cms width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
M&L preparation of new or previously untreated steel surfaces exc 10 cm width or girth (incl roof surface) and applying one coat of synthetic enameled paint complete all as specified and directed.
M & L for water proofing treatment of roof slab all as followes: - (a) M&L for preparation of roof surfaces by brushing, cleaning and Applying a priming coat with bitumen primer @ 0.5 ltr/Sqm (b) Applying a hot blown bitumen grade 85/25 @ 1.2 Kg/sqm (c) Laying APP modified water proofing membrane weighing not less than 3 Kg/Sqm will be laid over applied bitumen. (d) Applying a tack coat of hot bitumen grade 85/25 @ 1.2 Kg/Sqm and sand in confirming to Zone II in dry condition will be dusted over the bitumen @1.00 Kg/Sqm
M&L brick tiles 40 mm thick laid over 15 mm thick screed bed in CM 1:3 and jointed in CM 1:3 with linced oil @ 5% by weight of cement complete all as specified and directed.
M&L for chequered cement concrete tiles 30 cm x 30 cm x 25 mm thick , with grey cement and pigments, set & jointed in neat cement slurry and pointed with in floors laid over and including 20 mm thick screed bed or bedding layer in CM 1:4 complete all as specified and directed
Roughening surfaces of old concrete floor by picking , sweeping clean and washing down with water to remove dust etc complete all as specified and directed.
Taking down cement or cement lime plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc. complete all as specified and as directed.
M & L PCC 1:3:6, type C-1 (using 20mm graded stone aggregate) as in level course in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, , water troughs and the like including weathering, slightly rounded or chamfered angles and throating, complete all as specified and as directed.
M&L Machine cut kota stone 20-25 mm thick as in floor etc. laid and jointed with grey cement slurry mixed with pigment to match the shade of the stone including grinding and polishing laid over and including 20mm thick screed bed CM (1:6) complete all as specified and directed.
M & L Marble tiles 20 to 25mm thick machine cut, bedded jointed and pointed with grey cement slurry including cutting and polishing types incl pointing in white cement (1:2) using marble dust with admixture of pigment to match with marble shade of makrana white laid over and including 20mm thick screed bed CM (1:6) complete all as specified and directed.
M&L Machine cut kota stone 12 to 15 mm thick as in riser of step, skirting, dado and pillar etc. laid and jointed with grey cement slurry mixed with pigment to match the shade of the stone including grinding and polishing laid over and including 15mm thick rendering CM (1:4) complete all as specified and directed.
Taking down & Refixing the shutters of any description exc 1.00 Sqm but not exc. 2 Sqm each in the same opening after easing and adjusting complete all as specified and directed.
M&L for complete removal of existing treatment on old plastered or unplastered surface including preparation of surface of walls and applying two coat of distemper oil emulsion on wall over a coat of wall care putti complete all as specified and directed
M&L for point wiring concealed type with 1.50sqmm PVC FRLS insulated, unsheathed, single core, multi stranded copper conductor cable 1100 volts grade including 1.5sqmm FRLS PVC insulated unsheathed stranded copper conductor cable as earth continuity conductor drawn in and including rigid PVC conduit of suitable size but not less than 20mm dia with its accessories, sunken type pressed steel terminal box made of 1.2mm thick MS sheet/ anodised steel box painted with one coat of red oxide primer including 3.0 mm thick ISI marked plastic laminated sheet cover for fixing switches/ socket/regulators etc including cutting chases in wall as per standard engineering practice & making good the disturbed surfaces to match with existing for the one light/ fan/street/bell point controlled by 1 one way switch 5/6 Amps complete all as specified & directed.
All as per item No 58 here in before but One socket outlet 5/6 Amps on independent bd controlled by one switch.
All as per item No 58 here in before but One socket outlet 5/6 Amps controlled by one switch on same board with other switches
All as per item No-58 here in before but using 2.5 sqmm PVC FRLS insulated stranded copper cunductor cable and for one socket out let 3/6 pin, 15/16 Amps controlled by one 1 way switch on independent board complete all as specified & directed. NOTE-For item no 58 to 60-: (i)The quoted rates shall be deemed to be inclusive for cutting chases in brick walls/pillers etc for concealing the conduits to required depth & making good the disturbed surfaces in cement mortar 1:4 including finishing the surface to match with the existing surface.The portion of point wiring at RCC Coloumns/Beams/Ceilings etc shall be in surface conduit of suitable size fixed on surface with using PVC rawl plug and provision of covering terminal boxes/junction boxes of any shape and size with 3 mm thick bakelight laminated sheet fixed with suitable GI screws and cup washers. (ii) Fittings like switches,sockets,regulators,lamp holders,light foittings shall be measured and paid for separately under appropriate item of schedule A. (iii)The size of conduits shall be determined on permissible no of runs of wires as specified in SSR part-I clause 19.125 (B).However minimum size of conduit shall be 20 mm dia (medium grade)
Supply and fix switch piano, flush type, single pole, 5/6 Amps one way, 230 volts complete all as specified and directed. Make: Anchor Cat No.38058 or equivalent as approved by GE.
Supply and fix switch piano, flush type, single pole, 15/16 Amps one way, 230 volts complete all as specified and directed. Make: Anchor Cat No.39991 or equivalent as approved by GE.
Supply and fix socket outlet, 5/6 Amps, flush type, 5 pin 230 volts complete all as specified and directed. Make: Anchor Cat No.38320 or equivalent as approved by GE.
Supply and fix socket outlet, multi-purpose 3 pin 5/6 Amps and 3 pin 15/16 Amps complete all as specified and directed. Make: Anchor Cat No.39994 or equivalent as approved by GE.
S&F for ceiling rose surface bakelite 62.5 x 25 mm size 3 terminals complete all as specified and directed. Make -Anchor CAT Part No-39072 or equivalent as approved by GE.
Supply and fix lamp holder insulated body with back plate for batten fitting complete all as specified and directed. Make: Anchor Cat No. 39797/ 39800 or equivalent as approved by GE.
Supply & fix rotory stepped type electronic fan regulator mini flush type 100 watt 230 Volts complete all as specified & directed. Make: Anchor Cat No.38284/38660 or equivalent as approved by GE.
Supply and fixing LED Bulb 15 watt, single phase, 230 Volts AC supply suitable for lamp holder complete all as specified and directed. Make :- Make:- Havells cat part No-LHLDDEEEML8R015 or equivalent Model of Philips/Bajaj/CG/ Wipro as approved by GE.
Supply & fix surface/wall mounting LED batten 20 watt luminaire having extruded aluminium housing provided for efficient heat dissipation with polycarbonate diffuser and integrated electronic driver with mounting accessories complete with lamp holders fixed to wall/ ceiling with fixing accessories and connecting up with & including twin twisted copper flexible wire of size 0.75 sqmm from ceiling rose to fittings complete all as specified & directed. Make:- Havells cat part No-ENDURALINEAR NEOBS20WLED865SPCWH or equivalent Model of Philips/Bajaj/CG as approved by GE.
Supply & fix, outdoor security light LED 36/40 watt luminaire IP 65/66 protection polyster powder coated with pressure die cast aluminium housing and robust construction with reflector cover pre anodised and flat white high transmission acrylic cover or toughened glass, natural white type with electronic driver, connector block etc with internally prewired fixed to building with and including 1.20M long bracket made out of 40mm dia light grade GI pipe bent to shape & providing clamps 2 Nos made out of 50 x 6 mm Flat iron/MS clamps & 12mm dia bolts, nuts & washers etc and connecting up with & including twin twisted copper flexible wire from ceiling rose to fittings complete all as specified & directed. Make:- Havells cat part No- ENDURAPEARLNEOSL40WLED757PASYTOPC,Phillips cat part no BRP052 LED 036 CW HP SLA FG S1 PSU GR or equivalent as approved by GE.
Supply & fix surface mounting type bulkhead 10 watt LED luminaire with reflector cover electronic driver, connector block etc with internally prewired fixed to wall with fixing accessories and connecting up with & including twin twisted copper flexible wire from ceiling rose to fittings complete all as specified & directed. Make:- Havells cat part No- Cat part No FT10WLED857SSYMBOPC or equivalent model of make Philips/ Bajaj/ Crompton Greaves as approved by GE.
Supply and fix MCB DB sheet metal enclosure factory fabricated double door SPN 8 way with 100 amps rated copper bus bar 240 volts IP-43, IK-09 with metal doorscomplete all as specified and directed. Make:- Legrand Cat Part No. 5076 11 or equivalent model of make Siemens/ Schneider as approved by GE.
Supply & fix Isolator SPN , 40 Amps, 240 volts, 50Hz, IP-20 as per IEC 60947-3 ISI marked complete all as specified & directed. Make:- Legrand CAT No. 4065 01 or equivalent model of make ABB/ L&T/ Schneider as approved by GE.
Supply & fix MCB SP, 6 to 32 Amps, 'C' curve, 240 volts, 50Hz, 10kA IP-20 as per IS/IEC 60898-1 2002 ISI marked complete all as specified & directed. Make:- Legrand CAT No. 4085 87 to 4085 95 or equivalent model of make Siemens/ Schneider as approved by GE.
Supply and fix ceiling fans, complete with three blade, down rod, accessories 230V, 1200mm sweep, with Squirrel cage induction motor complete all as specified and directed. Make :- Havells, Bajaj, Khetain, Usha
M & L earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm size, buried directly in ground (earth pit not less than 2.25 M deep below normal ground level) with top edge of the plate not less than 1.5 M below normal ground level connected to and including galvanised steel earth lead wire of 4 mm dia, including 15 mm bore GI light grade protection pipe upto 1 Mtr above the floor level of the buildings where main switch, DB etc, situated, earth lead wire connected to the earth plate by means of GI bolts, nuts, washers and earth plate surrounded by 150 mm thick alternate layers of charcoal or cock dust mixed with common salt 20 mm bore medium grade GI watering pipe PCC pit in PCC 1:3:6 type C-1 (using 20 mm graded stone aggregate) cover of precast RCC 1:2:4 type B-1(using 20 mm graded stone aggregate) duly reinforced with 8 mm formed or twisted bars @ 100 mm c/c both ways, GI wire mesh, GI sheet funnel necessary excavation in soft/ Looose soil and deposited the surplus soil to a distance not exceeding 50 mtr away from starting point, all as per electrical plate no:3 of SSR part-1 .
M&L for electrically disconnecting and taking down existing ceiling/Exhaust fans from any hight or in any position from existing bldg and keeping in safe custody for reuse at site after necessary repare/ servicing & painting with one coat of synthetic enable paint and writing of MES/identification No. of fans and re hanging/ re-fixing in original position but including replacement of three cor flexible copper conductor cable from ceiling rose to fan connector block of soze 0.75 Sqmm and hanging fan clamps, nuts, bolts and rubber reel bush etc & testing for proper functioning complete all as directed.
Supply & Laying, testing, cable XLPE insulated screened PVC bedded galvanized steel strip or wire armoured electric power cable (heavy duty) 1100 volt grade, with stranded aluminium conductor of size 16 Sqmm 2 core compele all as specified and as directed. Make :- Havells, Grandlay, Polycab, Finolex
Supplying and laying un-rainforced precast concrete cable cover LV type-I flat size 250 mm x 150 mm x 40 mm in trenches for protection of cable complete all as specified and as directed.
M&L for sand cushioning dry fine for cable cushioning below and above the cable complete all as directed.
Supply and fixing GI Pipe 40mm Light grade, for cable protection laid in trench under road or path or fixed on pole or wall with clamps with all fittings complete all as specified and as directed.
Arun Construction Co.
M/S A A DRILL EXPERT
PD GUPTA AND COMPANY
M/s J S & SONS
saroj constructions
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .