Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.1 LAccepted-AOC | L1 | Accepted-AOC Accepted being L1 | |
| 2 | L2₹21.8 L+₹27,128 (1.26%)Rejected-AOC | L2 | Rejected-AOC Rejected being L2 | |
| 3 | L3₹21.9 L+₹36,601 (1.70%)Rejected-AOC | L3 | Rejected-AOC Rejected being L3 | |
| 4 | L4₹22.0 L+₹42,711 (1.98%)Rejected-AOC | L4 | Rejected-AOC Rejected being L4 | |
| 5 | L5₹22.0 L+₹44,783 (2.08%)Rejected-AOC | L5 | Rejected-AOC Rejected being L5 |
Tender Value
₹19.8 L
EMD Value
₹39,500
Closing Date
2 Jan 2023, 6:00 pmClosed
GE 867 EWS
GE 867 EWS PIN-913867 C/O 99 APO
REPAIR AND MAINTENANCE OF GYSERS, EXHAUST FAN, LIGHTENING CONDUCTOR, EARTHING, COOLING APPLIANCES VOLTAGE STABILIZER, DG SET AND MISC ALLIED WORKS AT KALIMPONG UNDER GE 867 EWS
2022_MES_567294_1
GE/867/TOKEN/25 OF 2022-2023
Open Tender
Civil Works
Item Wise
180 days
KALIMPONG
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE 867 EWS
₹39,500
18 Feb 2023
5 Dec 2022
4 Jan 2023
5 Dec 2022
2 Jan 2023
19 Dec 2022
5 Dec 2022 - 15 Dec 2022
Amount
Routine maintenance consisting of normal repairs with periodical routine maintenance and testing of 50 KVA DG Set complete of following ( i,e. Engine, alternator etc under GE 867 EWS all including consumables items like cotton waste cloth kerosene oil etc. Maintenance will be carried out as and when ordered in writing by Engineer-in-Chare of maintenance schedule. Note- Accessories / spares/ new engine oil required for replacement will be measured and paid separately under respective items of schedule ‘A’ as supply only. (i) Change engine oil. (ii) Changing of oil filters, fuel filters screen filters assy. (iii)Changing of water filter. (iv) Making up coolant (v) Clean alternator winding in position by forced air and internal surfaces lubricate (vi) Tightining of all nut bolts. (vii) Greasing of all points. (viii) Checking of any leaking in fuel & oil lines
Routine maintenance consisting of normal repairs with periodical routine maintenance and testing of 40 KVA DG Set complete of following ( i,e. Engine, alternator etc under GE 867 EWS all including consumables items like cotton waste cloth kerosene oil etc. Maintenance will be carried out as and when ordered in writing by Engineer-in-Chare of maintenance schedule. Note- Accessories / spares/ new engine oil required for replacement will be measured and paid separately under respective items of schedule ‘A’ as supply only (i) Change engine oil. (ii) Changing of oil filters, fuel filters screen filters assy. (iii)Changing of water filter. (iv) Making up coolant (v) Clean alternator winding in position by forced air and internal surfaces lubricate (vi) Tightining of all nut bolts. (vii) Greasing of all points. (viii) Checking of any leaking in fuel & oil lines
Routine maintenance consisting of normal repairs with periodical routine maintenance and testing of 25 KVA DG Set complete of following ( i,e. Engine, alternator etc under GE 867 EWS all including consumables items like cotton waste cloth kerosene oil etc. Maintenance will be carried out as and when ordered in writing by Engineer-in-Chare of maintenance schedule. Note- Accessories / spares/ new engine oil required for replacement will be measured and paid separately under respective items of schedule ‘A’ as supply only (i) Change engine oil. (ii) Changing of oil filters, fuel filters screen filters assy. (iii)Changing of water filter. (iv) Making up coolant (v) Clean alternator winding in position by forced air and internal surfaces lubricate (vi) Tightining of all nut bolts. (vii) Greasing of all points. (viii) Checking of any leaking in fuel & oil lines
Supply only new Engine oil 15 W 20 Make : HP/BP/Indian
Supply only fuel filter suitable for 50 KVA DG Set.
Supply only fuel filter suitable for 40 KVA DG Set.
Supply only fuel filter suitable for 25 KVA DG Set.
Supply only lubricant oil filter suitable for 50 KVA DG Set.
Supply only lubricant oil filter suitable for 40 KVA DG Set.
Supply only lubricant oil filter suitable for 25 KVA DG Set.
Supply only air filter element suitable for 50 KVA DG Set.
Supply only air filter element suitable for 40 KVA DG Set.
Supply only air filter element suitable for 25 KVA DG Set.
Supply & top up water coolant in radiotor of DG set of any capacity any make, Make : TVS Girling/volvo line or of equivelent make all as directed by Engr-incharge.
Cleaning of the fuel tank of DG sets of 50/40/15 KVA capacity after decaning the diesel, after through cleaning with kerosene oil including replacement of level indicator pipe complete all as directed by Engr-incharge.
M & L for cleaning/washing the radiator complete all as directed at site by Engr-incharge
Dismantling the incinerator, cleaning completely all the parts and carrying out necessary repair.And re-assembling the incinerator and testing after re-assembling, complete all as directed by Engr-in-Charge.
Routine maintenance consisting of normal repairs with periodical routine maintenance and testing of Mechanical Laundry set Laundry Machine 30 kg capacity complete of following ( Dismantiling machines , cleaning completely all the parts and carrying out necessary repair, re-assembling and testing). All as directed by Engr-incharge.
Routine maintenance consisting of normal repairs with periodical routine maintenance and testing of Mechanical Laundry set Dryer 30 kg capacity complete of following ( Dismantiling machines , cleaning completely all the parts and carrying out necessary repair, re-assembling and testing). All as directed by Engr-incharge.
Routine maintenance consisting of normal repairs with periodical routine maintenance and testing of Mechanical Laundry set Extractor 15 kg capacity complete of following ( Dismantiling machines , cleaning completely all the parts and carrying out necessary repair, re-assembling and testing). All as directed by Engr-incharge.
M&L in replacement of Earthing complete with galvanized steel earth plate electrodes 600x600x6 mm thick buried directly in ground earth (earth pit not less 2.25 m deep below ground level) with top edge of the plate not less then 1.5 mtr below normal ground level connected to galvanised iron wire 4mm dia by means of bolt nuts check nuts and washers of galvanized iron or steel all as specified & shown in electrical plate No.3 of MES SSR part-I 2009 connected to earth test point as specified and testing on completion including provision of 40 mm dia light grade pipe up to 7.5 mtr length as protection & watering pipe shall be 20 mm bore medium grade including all excavation & earth work and testing complete in any type of soil incl PCC pit (1:3:6) type C-1 with RCC cover including charcoal , salt, funnel, all as specified and directed at site.
S&F aluminium strip 25x3.15 mm thick saddle/mounted on porcelain insulator / laid in trench complete all as specified and as directed.
Servicing AC Split type 1.5/2 TR indoor and outdoor unit cleaning of all parts i.e. cooling coil, blower motor ,fan blades, water tray, air filter, replacement of minor parts such as screws nuts, bolts, etc and wiring kit complete after completion testing complete including taking out and refixing or all as specified and as directed by Engr-in-Charge.
Taking out for repairing of defective AC Split type 1.5/2 TR indoor and outdoor unit and checking of wiring and rectification of defects including necessary dismantling and taking out for reparing and refixing and replacing spares as required complete all as directed by Engineer-in-Chare. Note:- Accessories / spares required for replacement shall be measured and paid separately under respective items of schedule ‘A’ as supply only.
Supply only Starting relay suitable for split AC.
Supply only Running capcitor 45 mfd + 06 mfd suitable for split AC.
Supply only Condenser fan blade suitable for split AC.
Supply only Starting capacitor 100/120 mfd suitable for split AC.
Supply & Fixing in repairs sealed unit compressor (replaced with original company repaired) for Capacity 1.5 Ton to 2 Ton suitable for split AC.
Material & labour for Gas Charging R22 to split AC of any capacity.
Supply & fixing in repairs Blower motor suitable for split AC.
Supply & fixing in repairs Drain pipe suitable for split AC.
Dismantling the blower motor of any capacity split AC,cleaning completely all the parts, taken out burnt out winding and fresh winding with super enamelled copper wire of existing sizes including varnishing, re-assembling of the motor by replacement of ball bearings including painting of two coats synthetic enamel paint of approved colour and testing complete all as specified and as directed by Engr -in- Charge.
Transporting of defective refrigerator of any make and capacity from MES store yard ro Contractor workshop for carrying out necessary repair and rectification of defects including necessary dismantling and taking out for reparing and refixing and replacing spares as required including bringing back to MES storeyard/ directed location after repair and testing complete all as directed by Engineer-in-Chare. . Note:- Accessories / spares/ Gas charging required for replacement shall be measured and paid separately under respective items of schedule ‘A’ as supply only.
Supply only Starting capacitor suitable for 190 to 230/250 to 345 Ltr capacity refrigerator.
Supply only Termostat switch suitable for 190 to 230//250 to 345 Ltrr capacity refrigerator.
Supply & Fixing in repairs Freezer chamber (Evaporator coil) suitable for 190 to 230//250 to 345 Ltr capacity refrigerator.
Supply & Fixing in repairs Compressor suitable for 190 to 230//250 to 345 Ltr capacity refrigerator.
Material & labour for Charging of refrigerant gas R-134A/R-22 for refrigerator & deep freezer.
Transporting of defective Deep freezer of any make and capacity from MES store yard to Contractor workshop for carrying out necessary repair and rectification of defects including necessary dismantling and taking out for reparing and refixing and replacing spares as required including bringing back to MES storeyard/ directed location after repair and testing complete all as directed by Engineer-in-Chare. Note:- Accessories / spares/ Gas charging required for replacement shall be measured and paid separately under respective items of schedule ‘A’ as supply only.
Supply only Capacitor 3 mfd suitable for 150 to 205/300 to 335 Ltr capacity deep freezer
Supply only Starting capacitor suitable for 150 to 205/300 to 335 Ltr capacity deep freezer
Supply only Filter strainer suitable for 150 to 205/300 to 335 Ltr capacity deep freezer
Supply & fixing in repairs Expansion valve suitable for 150 to 205/300 to 335 Ltr capacity deep freezer
Supply & Fixing in repairs Compressor suitable for 150 to 205/300 to 335 Ltr capacity deep freezer
Dismantling and taking out voltage stabllizer upto 5 Kva incl transformer unit, auto transformer varier, electric circult board, all cable connections, including repairing/replacement of push on switch, transistor, capacitor, relay transistor, diode, condenser, voltmeter, PVC connector, indicator lamp, cutout, MCB complete parts along with testing commissioning and trasportation charges from site to workshop all as directed by Enge-in-Charge.
Labour only for disconnection of off road existing security light fitting of any type by isolating jumper from OH line, terminal connection from junction box and removing carbonised/defective part of the cable including replacement of unserviceable cable connection and reconnecting the same after making security light in ON road position complete all as directed by Engr-in-Charge. Note : New cable connection will be measured and paid separately under respective item.
Supply and fix in replacement of Street light driver of 40 watts/ 45 watt, 230 V, 50 Hz suitable for operation over voltage range and by removing from existing position complete as per following make and model complete all as specified and directed by EIC. Model-LSTS-40-CDL/ENDUEAPEARLNEOSL45WLED757SASYTOPC Make - Crompton/ Philips/ Surya/ Havells Note: i) T & P required for carry out the repair work on street lights ata height up to 15 Meter will be arranged by contractor and rates for the same deemed to be included in quoted rates. ii) Contractor is bound to provide material to match the technical specification of LED fittings and material is also required to fix casing of LED fiting. iii) BEfore quoting the rate of driver contractor should check the technical specifications of the driver.
All as per item No 48 above but cap of 50 Watt/ 60 Watt LED fitting complete as per following make and model or as directed by EIC. Model 1) LSTP-60-CDL 2) Havells Model - Jeta Neo 50 (IP65) / ENDURAPERALPLUSSL60WLED757SSASYTOC 2) Surya Model- SLEUL60WIP66LXN Make - Crompton / Philips/ Surya/ Havells.
All as per item No 48 above but cap of 90/120/110 Watt LED fitting complete as per following make and model or as directed by EIC. Model 1) LFLN-120-CDL/60" 2)LFLN11-110-CDL/60 3) Surya Model - SELFL120WIP65LUMOS 4) SLEUL90W IP66LXN Make - Crompton / Philips/ Surya/ Havells.
All as per item No 48 above but cap of 35 Watt LED fitting complete as per following make and model or as directed by EIC. Model 1) RUBYPT35WLED757PSYMTOPC Make - Crompton / Philips/ Surya/ Havells.
All as per item No 48 above but cap of 08 Watt BAMBOO bollard light LED fitting complete as per following make and model or as directed by EIC. Make - Crompton / Philips/ Surya/ Havells.
All as per item No 48 above but cap of 15 Watt post top, LED fitting complete as per cat part No RUBYMINTPT15WLED757PSYMTOPC of Havells.
Trimming of tree branches which touches the LT/HT OH lines and 2.5 Mtr away from centre line of LT/HT oh lines span not exceeding 60 Mtr distance between poles by using neccessory T&P items and depositing the tree branches/leaves at 30 Mtrs away from the site . Note -Any number of tree branches cut in one span will be measured as one lenght of payment.
Material and labour for Stringing of existing stays after dismantling from pole and refixing the same afetr properly straightning of conductor complete all as directed by Engr-in-Charge
Taking out and relaying of existing brick/cable cover to the existing trench after completion of fault finding work of cable complete all as directed. Note :- Excavation work will be paid under respected item.
Material and labour for taking out and relaying of existing cable of any size after completion of fault finding work of exiting cable complete all as directed. Note :- Cost of excavation of cable will be paid respective item.
Restringing of existing LT overhead line including removing the existing binding wire and rebinding with new binding wire after tightning of overhead lines including disconnecting existing jumper and connections and reconnecting after tightning of conductor incl replacement of all jumpers all as directed by Engr-In-Charge. Note - (a) Single wire run of conductor in LT lines shall be measured as one length for payment purpose. (b) ACSR conductor will be measured and paid separately.
M&L for painting of 9 Mtr Long steel tubular LT pole , vertical complete with cross arms with one coat of aluminium paint after cleaning and preparation of surfaces of poles , cross arms, apinting 30 cm wide Yellow and black strip on poles upto 1.5 mtr high above coping level and numbering of size 70mm x 40mm by using stencil to the pole with black synthetic enemal paint (1st grade) complete all as directed.
Excavation in trenches not exc. 1.5 m wide and not exceeding 1.5m depth for foundation of poles/laying of cables/stay/strut etc not exceeding 10 Sq m on plan and getting out in soft/loose soil all as specified and directed.
Returning, filling including spreading, leveling watering and well ramming in layers not exceeding 25 cm all as specified and directed.
Removing excavated material (soil) n.exc 50m and depositing where directed at a level not exceeding 1.5 mtr above the starting point all as specified and directed.
M&L for providing dry river sand as in sand cushioning to under ground cable including punning down of sand in layers as specified and as directed.
15. Supplying and laying Bricks common burnt clay building bricks, sub-class ‘B’ for cable protection complete as specified and as directed by Engr -In-Charge.
Supply & Laying in replacement of GI pipe bore dia 40mm light grade as protection for UG cable/for stand of post top lantern complete all as specified & directed.
Supply & Laying in replacement of GI pipe bore dia 25mm light grade as protection for UG cable/for stand of post top lantern complete all as specified & directed.
Supply and fixing in replacement LED street light fitting 35 Watt 230V AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver , lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete. Make - Philips/ wipro/ Crompton
Supply and fixing in replacement LED street light fitting 70/72 Watt 230V AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver , lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete Make - Philips/ wipro/ Crompton
Supply and fixing in replacement LED flood light 100 Watt 230V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp Make - Philips/ wipro/ Crompton
Supply & fixing in replacement automatic street light switch of rating 8 KW in single phase using nature sensor for automatic switching "ON/OFF" of street lighting based on lux level of natural light alongwith 63 Amps contactor. MCB 63 Amps with support terminals prewired with PVC insulated 16 Sqmm multi sttrand copper wire enclosed / housed in pole wall mounted enclosure made of rust proof , shock proof, termite proof & dust proof FR grade moulded compound Junction Box complete all as specified. Model - SWADEEP- 02EC 8KW 1P make - 1. Nature- Nature Switch : Kakatiya ENergy systems Pvt Lrd/ HEALER/ BAJAJ 2. Contactor : BCH/ L& T/Schneider 3. MCB : Hager/ Schneider / L&T/ C&S 4. Circuit wiring : Finolex / Polycab or equivalent
Supply and fixing in repairs post-top-luminaire, 15 watt, IP-65 protoection, operating temp -10 degree celcius to +45 degree celcius, Operating voltage range - 140-270 V, guaranteed burning life 50000 hours, Die-cast aluminium spigot housing for mouting of driver with spun aluminium canopy painted white inside, epoxy powder coated matt black finish, Lumen efficacy >140 lm/watt, high quality polycarbonate cover with acrylic diffuser, electronic driver powered by integral in ABS housinng with APFC, SMPS based constant current supply with lower THD, Short ciruit, over voltage, surge voltage protection as per IS 15885 Part-2/Sec -3. Mounting suitable for pole having 50 to 70 mm dia complete all as specified and directed by Engineer-in-charge. Make : Havells, cat part No RUBYMINIPT15WLED757PSYMTOPC, Model : RUBY (Clear) or equivalent.
Supply and fix in replacement of surge protector of 5 KV suitable to accomadate in LED street/flood light fittings of 25/30/36/45/60/72/100/120/135/150/165 and 200 Watts, 230 V, 50 HZ by removing from existing position complete all as specified and directed by EIC. Note : i) T&P required for carry out the repair work on street lights at a height up to 15 meter will be arranged by contractor and rates for the same deemed to be included in quoted rates. ii) Contractor is bound to provide material to match the technical specification of LED fittings and material is also required to fix inside casing of LED fitting. Make-Philips/Wipro/Crompton/Goldwyn/Decorex.
M&L for Painting of complete GI post top light fitting pipe hight upto 1 mtr with PCC protection of pipe by applying single coat of synthetic enamel paint after preparation of existing surface of GI post , colour as existing or directed by Engineer in charge.
Dismantling / Taking out Unserviceable LT cables of size upto 35 sqmm any core from any position i.e ground / walls / poles / culverts etc complete with protection pipe all as specified and directed by Engineer-in-Charge.
Supply, laying, testing & commissioning in repairs in trenches or passing through pipe, heavy duty under ground cable PVC insulated, armoured, over all PVC sheathed with stranded aluminum conductor 1100 volts grade of cross sectional area 10 sq mm 4core complete all as specified and directed.
Supply, laying, testing & commissioning in repairs in trenches or passing through pipe, heavy duty under ground cable PVC insulated, armoured, over all PVC sheathed with stranded aluminum conductor 1100 volts grade of cross sectional area 06 sq mm 4core complete all as specified and directed.
Supply, laying, testing & commissioning in repairs in trenches or passing through pipe, heavy duty under ground cable PVC insulated, armoured, over all PVC sheathed with stranded aluminum conductor 1100 volts grade of cross sectional area 16 sq mm 4core complete all as specified and directed.
Supply, laying, testing & commissioning in repairs in trenches or passing through pipe, heavy duty under ground cable PVC insulated, armoured, over all PVC sheathed with stranded aluminum conductor 1100 volts grade of cross sectional area 25 sq mm 4core complete all as specified and directed.
Taking down copper/aluminium point wiring (light fan, Socket or power ) Complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, light fitting etc, removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of wall, floors, etc. as directed by the Engineer – in - Charge.
Disconnection and taking down distribution boards, switch fuse unit, , enclosure for MCB including MCB's of any type and size and keeping aside for reuse of serviceable one.
Material and labour for point wiring with 1.5 Sqmm (nominal area) PVC insulated un - sheathed single core multi stranded copper conductor FRLS cable 1100 volts grade (conforming to IS) drawn through and including rigid non metallic PVC casing and capping not less than 20mm size, medium grade with all necessary fittings, surface wiring , for light /fan/Bell point controlled by one switch including 1.5 Sq mm PVC insulated copper stranded conductor for earth continuity conductor and connected to earth dolly and to be terminated in 1.6 mm thick pressed steel terminal boxes/PVC Boxes (concealed type in permanent bldg and surface in temporary bldg or as directed ) for mounting fittings like switch, socket, fan regulator etc. with 3 mm thick laminated bakelite sheet cover ,for housing switches, socket outlet, regulator etc. complete all as specified or directed including testing on completion.
All as per item No 81 here – in – before but for one switch socket outlet 15 Amps on independent board with 2.5 Sqmm multi stranded and 2.5 Sq mm stranded (for earth) PVC insulated un-sheathed copper cable.
Supply and fixing in repairs switch socket combination 2 – in – one 6 Pin , 5 / 15 amps flush type universal all as specified and as directed. Make : Anchor/Havells/Plaza
Supply and fix in repairs switch piano flush button, single pole, 5 amps, one way all as specified and as directed. Make : Anchor/Havells/Plaza
Supply & Fixing in repairs ceiling rose surface bakelite 65 X 50 mm three terminal all as specified and as directed. Make : Anchor/Havells/Plaza
Supply and fixing in repairs Sheet metal enclouser Double door for MCB DB,s Phosphatised Powder Painted with bus bar 200 Amps rated Single pole and neutral linkof 4 way 240 Volts AC. Make- Legrand / Siemens/Schindler.
Supply and fixing in repairs Sheet metal enclouser Double door for MCB DB,s Phosphatised Powder Painted with bus bar 200 Amps rated Single pole and neutral linkof 8 way 240 Volts AC. Make- Legrand / Siemens/Schindler.
Supply and fixing in repairs MCB Single pole and neutral 32 Amps capacity 10 KA 240 Volts 50 HZ. Cat Part No 4086 17 of Make- Legrand or equivalent in Siemens/Schindler.
Supply and fix in repairs MCB single pole (SP), 10 kA of 5 Amps to 30 Amps capacity 240 Volts. Cat part no 4086 95. Make- Legrand/Siemens/Schindler.
M&L in repairs for sub main wiring along with earth wire of size two run of 6 sq mm + one run of 6 Sq mm earth wire single core PVC insulated cable with stranded copper conductor FRLS including drawing into 25 mm rigid non-metalic PVC casing caping on surface of wall/roof .(Note Three run of 6 Sqmm including one run of 25 mm of size casing caping shall be measured as one unit length including taking down of old servicible sub main wiring.
M&L in repairs for sub main wiring along with earth wire of size two run of 4 sq mm + one run of 4 Sq mm earth wire single core PVC insulated cable with stranded copper conductor FRLS including drawing into 25 mm rigid non-metalic PVC casing caping on surface of wall/roof .(Note Three run of 4 Sqmm including one run of 25 mm of size casing caping shall be measured as one unit length including taking down of old servicible sub main wiring.
S&F in metal plug socket single pole and neutral encloser with two pin earth plug with 01 No MCB SP 20 Amp, C series complete all as specified including taking down of existing old unserviceable fitting. Cat part No 5078 11 Make- Legrand or equivalent in Siemens/Schindler.
Taking down carefully electric storage type water heater (Geysers) of any make and any capacity from its mounting place opening for inspection compete including back plate, heating element, inner copper tank etc, de-scaling back plate and heating element by cleaning with Sulfuric acid/ de-scaling compound and re-assembling of Geysers after repairs carrying out and re-fixing in same position (Replaced items such as spares measured and paid separately under relevent items) including making good to disturbed portin of walls with CM (1:3) or PCC (1:2:4 Type B1) and plastering the wall surfaces with CM 1:6 and replacement of old nuts, bolts and rubber gasket etc, complete all as specified and as directed by the Engineer-in Charge. Note :- Any type of rubber gasket , rubber washer, screws , insulating tape required shall be deemed to be included in the quoted rate.
All as per item No. 93 herein before but for descaling / cleaning the inner tank including denting and brazing the leakage joints / points till the leakage stops including carrying out minor repair of outer body surface, bottom and top cover complete all as specified and as directed by Engineer-in-charge. Note :- Any damage caused during the process of cleaning the geysers shall be made good by contractor at no extra cost department.
S&F in replacement 2.0 KW capacity Heating Element, Push/ Screw type with ‘triangle cup/'O' Ring type' including making electrical connection complete all as directed by Engineer-in-Charge.
S&F in replacement 1.5 KW capacity Heating Element, Push/ Screw type with ‘triangle cup/'O' Ring type' including making electrical connection complete all as directed by Engineer-in-Charge.
S&F in replacement for Thermostat/autocut switches for geysers 25/ 50 Ltr capacities including making connection complete all as directed by Engineer-in-Charge.
S&F in replacement glass wool for insulation of geyser 25/50 Ltrs capacity and any make all as directed by Engineer-in-Charge.
Supply and fixing in replacement indicator lamp round /rectangular and making electric connections (Red/Green) 220 Volts AC as per site requirement suitable for geysers complete all as directed by Engineer-in-Charge.
Supply and fixing in replacement safety valve spring locked type with inlet coupling all as specified and directed by Engineer-in-Charge.
S&F in replacement plug top 15 Amps 240 Volts complete all as specififed and directed by Engineer-in-Charge.
S & F in replacement of fusible plug for suitable capacity of geysers complete all as specified and directed by Engineer-in-Charge.
S& F in replacement 2.5 Sqmm 3 core PVC insulated unsheathed stranded copper wire complete all as specified and directed by Engineer-in-Charge. MAKE:- ANCHOR/FINOLEX/PLAZA/ HAVELLS/ HPL/ POLYCAB
Dismantling of exhaust fans of 300mm sweep AC single phase 230/240 volts of any make / model except old vintage, dismantling stator, rotor, cutting out burnt copper winding and providing new winding with super enamelled copper winding wire of existing size including cleaning of slots providing oil impregnated insulation paper or minimax, fibre, insulation in slots and well wraping with cotton tape, bind with cotton thread and varnishing over all with winding varnish, cleaning of bearing housing and shaft, replacing spares such as split pins, blade screws, condensor, ball bearing etc, as required and reassebling complete all as specified and directed by Engineer-in-Charge.
All as per item No 104 here-in-before but 200/ 225/250mm sweep all as specified and directed by Engineer-in-Charge.
All as per item No 104 here-in-before but 150mm sweep all as specified and directed by Engineer-in-Charge.
Supply only ball bearings No 6203 suitable for fan of existing make type & sweep complete make NBC/SKF/TATA
Supply only 2.5 MFD capacitor suitable for exhaust fan of existing type & sweep complete of 300/250/150 mm capacity.
S&F heavy duty stainless steel inner tank suitable for 25 Ltrs capacity Geyser having high pressure bearing capacity including taking down existing copper / steel inner tank complete all as specified and as directed by Engineer-in-charge.
S&F heavy duty stainless steel inner tank suitable for 50 Ltrs capacity Geyser having high pressure bearing capacity including taking down existing copper / steel inner tank complete all as specified and as directed by Engineer-in-charge.
S&F in replacement top cover made of MS sheet 18 SWG duly painted with two coats of super enamel paint by spray painting suitable for 25 Ltrs geysers complete all as specified and as directed by Engineer-in-charge.
S&F in replacement top cover made of MS sheet 18 SWG duly painted with two coats of super enamel paint by spray painting suitable for 50 Ltrs geysers complete all as specified and as directed by Engineer-in-charge.
S&F in replacement bottom cover made of MS sheet 18 SWG duly painted with two coats of super enamel paint by spray painting suitable for 25 Ltrs geysers complete all as specified and as directed by Engineer-in-charge.
S&F in replacement bottom cover made of MS sheet 18 SWG duly painted with two coats of super enamel paint by spray painting suitable for 50 Ltrs geysers complete all as specified and as directed by Engineer-in-charge.
S&F in replacement of outer body fabricated of 1.6 mm MS Sheet for geysers of 25 Ltrs capacity duly painted with spray point with clamps 02 Nos of with necessary nut bolts complete all as specified and as directed by Engineer-in-charge.
S&F in replacement of outer body fabricated of 1.6 mm MS Sheet for geysers of 50 Ltrs capacity duly painted with spray point with clamps 02 Nos of with necessary nut bolts complete all as specified and as directed by Engineer-in-charge.
Supply and fixing in replacement of geyser assembly suitable for 25 ltr capacity ISI marked including dismantiling of old unserviceable geyser assembly complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of geyser assembly suitable for 50 ltr capacity ISI marked including dismantiling of old unserviceable geyser assembly complete all as specified and directed by Engineer-in-Charge.
Taking down exhaust fan of any size and cleaning all type dust, oil stains etc, painting with one coat of syntatic enamemel paint by spraying and refixing properly in the same location complete all as specified and directed by Engineer-in-Charge.
Supply & fixing PVC connection heavy duty with brass/PTMT nuts of reqd length not exceeding 300 mm with rubber & PVC washer suitable for 15 mm bore GI pipe complete for cold water.
Supply & fixing hot water outlet connection made of brass chromium plated with Union rubber washer suitable for 15 mm bore GI pipefor hot water.
Taking down carefully electric storage type water heater (Geysers) of any make and any capacity from its mounting place cleaning all type dust, stains etc, painting with one coat of syntatic enamemel paint by spraying and refixing properly in the same location complete all as specified and directed by Engineer-in-Charge.
M&L for shifting of exhaust fan from one place to another including making hole at new place and filling of hole at old place including all necessary electric connection, brick work, plastering and 2 coat of painting of size 150, 200, 250 and 300 mm dia all as specified and as directed.
Supply and fix in repairs Air terminatiion, single pointed copper rod 12mm dia 300mm long all as specified and directed by Engr -in- Charge.
M&L in repairs Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw all as specified and directed by Engr -in-Charge.
Earthing in repairs complete with galvanized steel earth plate electrode 600 x 600 x 6 mm buried directly in ground ( earth pit not less than 2.25 m deep below ground level ) with top edge of the plate not less than 1.5 m below normal ground level, connected to GI strip 32x6mm by means of galvanized iron or steel bolts , nuts , check nuts and washers, and connected to equipments as directed , including funnel with GI med grade watering pipe 20 mm bore , wire mesh , charcoal or coke and common salt in alternate layers of 15 cm compacted thickness all around the earth electrode , with concrete pit in PCC (1 : 3 : 6) type C-1 , 50 mm thick pre cast RCC (1 : 2 : 4) type B-1 cover slab reinforced with 8 mm dia deformed bar 15 cm C/C and suitable handle of 10 mm dia round bar ,GI medium grade pipe for earth lead protection including necessary excavation earth work in soft/loose soil and disposal of spoil to a distance n.exc. 50 m and necessary testing complete all as shown on electrical plate No. 3 of MES SSR Part-I and as directed.
S&F in repairs GI strip 32X6 mm complete and Buried in ground .
M&L in repairs porcelain/epoxy white/brown/green spacer insulator with one GI stud bolts with nut and washers with necessary drilling for bolts hole for holding/fixing roof conductor/ down conductor of lightening conductor complete all as specified and as directed.
Note: In case doubling/duplicancy of BOQ items , the lowest quoted rate shall be applicable for payment.
SCHEDULE OF CREDIT
MS BRAHMA CONSTRUCTION
JAYSHREE CONCERN
PRASAD PRADHAN AND SON
MANOJ JINDAL
S K ENTERPRISES
SANJAY SAW MILL
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .