| 1 | L1₹4.3 LAccepted-AOC 261 3 BESIDE ROYAL HOSPITAL KAMLA NEHRU NAGAR JABALPUR MADHYA PRADESH 482002 | JABALPUR | MADHYA PRADESH | 482002 | L1 | Accepted-AOC L1 | |
| 2 | L2₹5.3 L+₹76,993.97 (16.8%)Rejected-Finance 53 SHANTI S SANIK COLONY BAIRAGARH BHOPAL MP 462 030 | BHOPAL | BHOPAL | MADHYA PRADESH | 462030 | L2 | Rejected-Finance Not Admitted | |
| 3 | L3₹5.5 L+₹88,528.27 (19.3%)Rejected-Finance | L3 | Rejected-Finance Not Admitted | |
| 4 | L4₹5.6 L+₹1.0 L (22.1%)Rejected-Finance | L4 | Rejected-Finance Not Admitted | |
| 5 | L5₹5.7 L+₹1.1 L (24.6%)Rejected-Finance NEAR BUS STAND PACHMARHI MP PIN 461881 | PACHMARHI | HOSHANGABAD | MADHYA PRADESH | 461881 | L5 | Rejected-Finance Not Admitted |
Tender Value
Refer Docs
EMD Value
₹12,000
Closing Date
3 Mar 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE Indpt Pachmarhi
AGE Indpt Pachmarhi Dist- Hoshangabad (MP)-461881
REPAIR/MAINT OF WATER SUPPLY PIPELINE WITH ALLIED MISC WORKS AT KOHIMA COY,CHUSUL COY AND TITHWAL COY AT AEC TRG COLLEGE AND CENTRE PACHMARHI.
2022_MES_505935_1
CA No. AGE(I)/PACH/ of 2021-22(8456/E8)
Open Tender
Civil Works
Item Rate
180 days
Pachmarhi MP
Class E category a(ii)
8 documents required · 8 mandatory
₹500
AGE Indpt Pachmarhi
₹12,000
Yes
7 Jun 2022
4 Feb 2022
5 Mar 2022
4 Feb 2022
3 Mar 2022
18 Feb 2022
60 days
Amount
Taking up or taking down old unsv steel tubing and connections removal to store for the following sizes complete all as specified and directed :-
(a) 50mm bore
(b) 40mm bore
(c) 25mm bore
(d ) 20mm bore
Relaying of old GI pipe line after cleaning of joints and fittting as taking out against item No 1 for the following size :-
(a) 50mm bore
(b) 40mm bore
(c) 25mm bore
(d ) 20mm bore
Supply, fixing / laying, jointing and testing of GI pipes, medium grade, ISI marked with all fittings fixed on wall/ roof or laid in trenches/ floors complete all as specified including taking out the old pipe as directed for the following size :-
(a) 100mm bore
(b) 50mm bore
(c) 40mm bore
(d) 25mm bore
(e ) 20mm bore
S&F in repair sluice valve ISI Marked (IS 14846-2000), Class PN-1.6, both ends flanged with CI body, stainless steel spindle, chucknut and iron wheel etc including provision of new nuts, bolts, washers and gasket including testing complete all as specified and directed for following size :-
(a) 150mm bore
(b) 100mm bore
(c )80mm bore
S&F in repair Gun metal globe or gate valve with iron wheel head, ISI marked screwed both ends for iron pipes and fixed including taking down the old one complete all as specified and directed for the following size:-
(a) 50mm bore
(b) 40mm bore
(c )25mm bore
(d) 20mm bore
Taking up or taking down CI/DI pipe from position including opening of any type of joints for following sizes complete all as specified and directed :-
(a) 150mm bore
(b) 100 mm bore
Relaying of old CI/DI pipe after cleaning of joints and fittting as taking out against item No 6 for the following size :- Note: Jointing material will be measured and paid seperately
(a) 150mm bore
(b) 100 mm bore
Supply, fixing/ laying, jointing and testing of Cast Iron pipes with spigot and socket ends centrifugally cast, Class 'LA' in any length, laid in trenches or fixed on wall complete all as specified and as directed including taking down the old pipe for the following size :- Note : Run lead joints shall be measured and paid separately.
M & L for Excavation for taking out/laying cable/GI pipe in trenches in any type of soil not exc 1.5 m wide and not exceding 1.5 m deep for GI pipe of any size complete all as specified and directed by Engineer-in-Charge
Returning filling in including spreading, watering and well ramming in layers not exc 25 cm complete all as specified and directed.
Removing surplus soil to distance not exceeding 50 M and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
M & L for run lead joints with jointing materialof size 150/100 mm dia complete all as specified.
M & L for tyton joints ( rubber gasket ) of size 100 mm dia as per existing sample complete all as specified.
M&L for valve chamber of size 1500mm x 1500mm x 860mm (internal dimention) with brick masonty valve chamber, 100mm thich PCC (1:4:8) type D2 as in foundation, 200mm thick brick wall built in CM (1:6), 50mm thich coping of PCC (1:3:6) type C1, 15mm thick plastering in CM (1:4) to all internal and exposed surface including necessary excavation and earth work in soft/loose soil, MS sheet cover 6mm thickness along with angle iron frame of size 40 x 40 x 5mm with locking arrangement with necessary fixing materials like hinges, nut bolts etc (valve chamber cover shall be opened in two valves) and painting to MS cover with two coats of synthetic enamel paint over one coat of red oxide primer etc with and including dismantling and taking out existing damaged/ rusted valve pit cover of any size from valve pit chamber complete including demolish the old one all as specified and directed.
Supply and fixing of CI/DI fittings i.e. bends (any type, radius and angle), tapers any type (straight, bend increasing, decreasing or double socket etc), T- pieces single branch, 'Y' junciton double branch, cross (all sockets or socket and spigot), collars, caps and plugs etc suitable for & upto 150mm bore pipes complete all as specified and directed.
Supply and fixing Non return valve ISI Marked (IS 14846-2000), Class PN - 1.6, both ends flanged with CI body, having counter weight with leather sheet etc including provision of new nuts, bolts, washers and gasket including testing including taking out the old one complete all as specified and directed of following size :-
(b) 100mm bore
(b) 80mm bore
Demolition of brickwork or stone boulder masonry, built in cement mortar or cement lime mortar including all quoins,arches, pillars,etc. but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed.
M&L for brick work with modular size full brick subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius, built in CM (1:6) complete all as specified and directed.
M & L for demolition of concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed
M&L for PCC 1:4:8 type D-2 using 40mm graded stone aggregate as in flooring on existing sub base surfaces of OH tank,pump houses finished cement concrete surface even and smooth without using extra cement including necessary form work and concrete (PCC) to be cast in alternate bays complete all as specified and directed. complete all as specified and directed.
M&L for PCC 1:3:6 type C-1 using 20mm graded stone aggregate as in flooring on existing sub base surfaces of OH tank,pump houses finished cement concrete surface even and smooth without using extra cement including necessary form work and concrete (PCC) to be cast in alternate bays complete all as specified and directed. complete all as specified and directed.
M&L for PCC 1:2:4 type B-1 using 20mm graded stone aggregate as in flooring on existing sub base surfaces of OH tank,pump houses finished cement concrete surface even and smooth without using extra cement including necessary form work and concrete (PCC) to be cast in alternate bays complete all as specified and directed. complete all as specified and directed.
Taking down cement/ lime plaster of any description on brick work or stone walls etc including racking out joints hacking for key scrubbing down with water etc complete all as spfd directed.
M&L for 15mm thick rendering on surfaces of brick work or stone walling in CM 1:6 finishing the surface fair & even complete all as spfd and directed.
Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning,filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm and getting out in soft/loose Soil
S&F Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates
Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified
Painting of steel surface of any description, over 10cm in width or girth apply two coat of synthetic enamel paint over a coat of red oxide primar.
Roughening surfaces of old concretexfloor by picking, sweeping clean and washing down with water to remove dust, etc.
M&L for Non - skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match imcluding Screed bed or bedding layer of mortar 15 mm thick CM 1:4 for laying floor finishescomplete all as specified and directed.
M/S Shanti Enterprises
GHASI RAM SAHU
M/S RAKESH TRADERS
SUBIR KUMAR ROY
BRICKS ON CLOUD INFRA
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .