Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹45.8 LAccepted-AOC D 91 BLOCK D AMITY GREEN HASEMAU LUCKNOW PIN 226028 | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226028 | L1 | Accepted-AOC AOC Awarded | |
| 2 | L2₹47.2 L+₹71,410 (1.54%)Rejected-Finance | L2 | Rejected-Finance Other than lowest quoted tenderer |
Tender Value
Refer Docs
EMD Value
₹98,000
Closing Date
31 Aug 2021, 6:55 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE WEST ALLAHABAD
GE WEST ALLAHABAD NEW CANTT ALLAHABAD
PROVN OF CERTAIN SPECIAL REPAIR, LBW, REVENUE AND MINOR WORKS UNDER AGE(B/R-I) AND AGE(B/R-II) AT NEW CANTT ALLAHABAD
2021_MES_464720_1
8506/E8
Open Tender
Civil Works
Item Rate
180 days
NEW CANTT ALLAHABAD
Please refer tender documets
7 documents required · 7 mandatory
₹500
GE WEST ALLAHABAD
₹98,000
Yes
18 Oct 2021
3 Aug 2021
2 Sept 2021
3 Aug 2021
31 Aug 2021
17 Aug 2021
60 days
Amount
Demolition of brick work built in cement mortar complete all as specified and directed.
M & L Brickwork with fly ash bricks, straight or curved on plan exc 6m mean radius, built in, built in cement mortar 1:6 complete all as specified and directed.
Demolition cement concrete(un reinforced)in ground floor and packing n exc 15 cm thickness (below or above ground level)all as spd and directed.
Taking down chowkat or frames with shutters (without taking off shutters from the frames) area n exc 1.50 each.
Taking down chowkat or frames with shutters (without taking off shutters from the frames) area exc 1.5 but n exc 4.00 Sqm each.
S&F for solid single side prelam PVC sheet door frame of size 50mm x 95mm made out of 5 mm single side prelam PVC sheet used reinforced with MS squre tube complete all as specified and directed.
S&F Factory made solid PVC moulded door shutter with particle board core, 28 to 30 mm thick (stiles), with 2, 4 or 6 raised panel design with 2mm thick moulded prelam PVC sheet on the front face & 2mm plain colour PVC sheet on back face complete all as specified and directed.
Pressed steel frames for doors frame size 125 x 60mm with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete as specified, supplied and fixed
M&L for PCC 1:3:6 type C-1 (using 20mm graded stone aggregate) as in hold fasts including necessary use and waste of form work complete all as specified and directed.
S&F 2nd class hardwood 35 mm thick plain, framed, panelled shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle boardmedium density, wood particle board with commercial face veneers; supplied and fitted to chowkats
S & F 35mm thick Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edge of framing plain, chamfered or rounded, fitted with cut and mitred beds for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8. clause 8.20 (a); supplied and fitted to chowkats
S&F 300 mm aluminium alloy, anodised sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast of extruded sections and fixing bolts and sliding bolts of extruded sec or cast aluminium and fixed complete.
S&F 100 mm size Butt hinges extended aluminium alloy with galvanized mild steel hinges pin anodized and fixed type B-22.
S&F 150 mm size aluminum anodized barrel tower bolt of extruded section and fixed complete all specified and directed.
S&F 150 mm size aluminum cast type anodized handle all as specified and directed by Engineer-in-charge.
Taking down plaster from edges of RCC chajja or corners where steel reinforcement coming outs and filling with 15mm thick rendering in CM (1:3 ) and making drip course in roof projection and Chajja and after applying two coats of weather coat exterior paint over a coat of primer complete all as specified and as directed. Note :- Necessary scafolding upto four story will be provided by contractor and unit rate will be deemed including this aspect.
Steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded
Steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete without glazing bars, dovetailed or welded
Steel ventilators with centre hung shutter including hinges, steel peg stay, complete all as specified and directed.
M&L for 3mm thick sheet glass ordinary quality and glazing with oil putty in square n-exc 0.5 sqm in each pane complete all as specified & directed.
M&L for 3mm thick sheet glass Figured glass, pin head type and glazing with oil putty in square n-exc 0.5 sqm in each pane complete all as specified & directed.
S&F for galvanised M S Wire cloth of 0.56 mm nominal dia of wire and average width of aparture 1.18 mm fixed with tinned tack for galvanized wire staple complete all as specified & directed.
Dismantling floor ,wall and hearth tiling including cement mortar bedding ,removing serviceable tiles to store and rubbish off the premises.
M&L for plain cement concrete 25mm thick type B-0 1:2:4 (12.5mm graded stone aggregate) as floor finish without using extra cement.
M & L for non skid ceramic colour tiles 7-8mm thick (square/rectangular) area of each tiles exc 0.06 sqm but n exc 0.11 sqm , in floors etc set and jointed in neat cement slurry & pointed in white or colouir cement to match the surfaces over 15mm thick screed bed in cement mortar 1:6 all as specified and directed.
M&L for coloured glazed ceramic tiles in vertical surfaces 450x350x7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match over 10mm thick rendering/bakcing coat in cement mortar 1:4 all as specified and directed.
M&L for Non-skid Ceramic coloured tiles 7 to 8mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface over 15mm thick screed bed in cement mortar 1:6 all as specified and directed.
Taking down cement plaster on brick or stone walls incl wall tiles etc. with raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and directed
M&L for rendering 15 mm thick in CM 1:4 over brick or concrete surfaces finishing the surfaces even and smooth w/o using extra cement including mixing of WPC by weight of 2% of cement all as specified and directed. (Note WPC will be measured and paid separately as supply only)
M&L for rendering 15 mm thick in CM 1:6 over brick or concrete surfaces finishing the surfaces even and smooth w/o using extra cement including scaffolding working height n. exc 12.00 mtrs
Rendering 10 mm thick in cement mortar 1:3 on concrete surfaces in ceiling, finished fair & even complete including scaffolding working height n. exc 6.00 mtrs .
Supply only Integral waterproofing compound. (Dr Fixit)
Taking up or down steel tubing & connections 25mm bore including cleaning for re fixing or removal to store.
Taking up or down steel tubing & connections 20mm bore including cleaning for re fixing or removal to store.
Taking up or down steel tubing & connections 50 mm bore including cleaning for re fixing or removal to store.
Taking up or down steel tubing & connections 15mm bore including cleaning for re fixing or removal to store.
M&L for 15 mm dia steel tube medium grade galvanized with all fittings, concelled to wall, ceiling or laid in floor etc.
M&L for 20 mm dia steel tube medium grade, galvanised with all fittings, concealed to wall, ceiling or laid in floor etc.
M&L for 25 mm dia steel tube medium grade, galvanised with all fittings, concealed to wall, ceiling or laid in floor etc.
M&L for 50 mm dia steel tube medium grade, galvanised with all fittings, concealed to wall, ceiling or laid in floor etc.
Demolition of reinforcement cement concrete any description and in any position not otherwise specifically provided and removal of debries out side MD land.
M & L for 1000 litre capacity rotational molded polythene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-I.
S & F in repair Bib taps cast copper alloy chromium plated with half/quarter turn with handle, fancy type with wall flange, screwed down, screwed for iron pipe or for brass ferrule 15 mm bore complete.
S & F in repair Stop valves, cast copper alloy, screwed down, high pressure, with half/quarter turn with handle, fancy type, chromium plated, with long shank and cup (concealed type) screwed both ends including wall flange for iron pipe or for unions 15 mm bore complete.
S & F in repair Stop valves, cast copper alloy, screwed down, high pressure, with half/quarter turn with handle, fancy type, chromium plated, with long shank and cup (concealed type) screwed both ends including wall flange for iron pipe or for unions 15 mm bore complete. Note: wt of one stop valve shall not be less than 600 gms
S&F in repair Chromium plated brass angle valve with half/quarter turn type for 15mm bore pipe, fixed in repairs complete all as specified and directed.
S&F Brass CP mixer for mixing hot & cold water screwed down for iron pipe and fixed to WHB, for 15mm bore.
S&F Brass chromium plated tubular towel rail 20mm dia D type 600mm long between flangs including two bricket of each rail.
S&F Harrison rails of anodised aluminium alloy with fixing brackets stops, rollers etc
S&F in repairs C P bib cock long body half/quarter turn type (concealed type) including flange screwed down for iron pipe 15 mm bore all as specified.
Supply and fixing in repair low level PVC flushing cistern 10 Ltrs capacity valve less, symphonic action type white with inlet ball valve, float and handle including bracket complete with PVC long bend.
Supply and fixing in repairs vitreous China squatting pan of pattern(Orrissa pattern) size 580mm x 440 mm white with or strap front or back inlet and foot rests any pattern to flushing pipe and anti syphonage pipe and making good floor including lime concrete).
S&F Flush pipe of polyethylene of low or high density or PVC. 32 mm dia, for low level cistern to pedestal pan, including all joints including making good.
S&F in repair vitreous china wash bashin, snow white flat back with pedestal of size 630mm x 450mm oval shape including brackets including cutting for and pinning in ends of brackets in CM 1:3 including 32mm dia chromium plated waste coupling complete all as specified and directed.
S&F in repair Vitreous China Urinal Half stall type white of size of size 710 x 300 x 600 mm white with grating and union for discharge pipe complete including providing and fixing plugs bedding urinal against wall in CM 1:2 securing urinal to plugs with and including 60mm long brass screws pointing around urinal l back in cement complete all as specified. Make - Cera Cat No 4020102.
S&F 18-20mm thick granite (of any type) stone slab work (table rubbed and polished) as in wash hand basin laid over and including 20mm thick screed bed in cement mortar 1:6 set in white cement with pigment and pointed in white cement 1:2 using marble dust with admixture of pigment to match with shade including cutting in granite slab circular or oval shape for fixing of vitreous china wash hand basin of desired size and shape including rubbing and polishing and making sandwitch moulding to edges complete all as specified and directed. (Note - Breakage if any in granite slab will be born by the contractor).
S&F 18-20mm thick granite (of any type) stone slab work (table rubbed and polished) as in urinal partition wall bedded into wall, jointed and pointed with white cement with admixture of pigment to match the shed of wall including polishing, grinding and making moulding to edges complete all as specified and directed.
M&L for RCC M-25 (design mix) using 20 mm graded stone aggregate as in chajjas, shelves etc and the like, complete all as specified and directed.
Form work to chullah hood, chajjas, troughs and similar items including edges complete all as specified and directed.
Mild steel TMT bars 10 mm dia and over as Reinforcement for concrete and cut to length, bent to shape required including cranking looking ends and binding with and including mild steel wire (anamealed) not less than 0.90 mm dia complete.
S&F Gun-metal, globe or gate valves 25mm dia, with iron wheel head, screwed both ends for iron pipe.
S & F CP shower rose with or without swivel joints 70 mm size including fitting to steel pipe or union of 15 mm dia fixed as in repairs all as specified.
S&F in repair 150 mm dia C.P grating with or without hole
S&F PVC connection 15 mm size with P.T.M.T nuts of length 600mm complete.
S & F PVC float valve assembling for 25mm bore PTMT complete.
M & L for high density polyethylene (HDPE) pipes of 32mm dia pipes of prsure rating 6 kg per sqcm
S & F waste coupling of PTMT (half or full threaded) (minimum weight 32mm- 45gms/40mm-60gms of 32mm dia for WHB
M&L for 100mm cast iron floor trap with grating incl jointing with solvent cement etc as fixing in repair
M&L (SWR) gully trap 150x150mm dia setting and jointing with solvent cement etc
S&F in repair Soap dish, Vitreous China white, approximate size 160 x 160x 90 mm
M&L for preparation new plastered surfaces and applying three coats of white wash on Ceiling.
M & L for preparing new plaster surfaces of wall including cornices and applying three coat of white wash all as specified and directed.
M & L for preparing new plaster surfaces of wall including cornices and applying two coat of cement based paint all over a coat of pimer/chalk whitening as specified.
M&L for prepration of newly plastered wall surfaces and applying two coat of Oil Bound distemper over a coat of chalk whiting as primer.
M&L for preparation of old distempered surface of wall including cornices etc. by washing, rubbing down,scrapping down smoke soot, moulds, moss and efflorescent salt and trading oil and greasy spots and stopping of distempered surfaces and applying one coat of oil emulsion distemper of approved shade on surface of wall complete all as specified and directed.
M&L for preparation of old plastered or unplastered surface of wall including cornices etc. by brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salt and trading oil and greasy spots and removal of vegetation and applying one coat of Cement Base Paint white or tinted of approved shade complete all as specified and directed.
M&L applying two coats of synthetic enamel paint on new or previously untreated steel surfaces of any description over 10cm width or girth over a coat of red oxide primer including preparation of steel surfaces complete.
M & L applying two coats of synthetic enamel paint on new wooden surfaces of any description over 10 cm width or girth over a coat of pink primer including preparation of surfaces complete.
Excavating in trenches n. exc 1.5 m width and n. exc 1.5 m in depth for foundation etc or for shafts, wells,cesspits , manholes , pier holes etc n exc 10 sqm on plan and n exc 1.5 m in depth and getting out soft/loose soil complete all as specified and as directed.
Returning filling in ,including spreading ,levelling,watering and well ramming in layers n exc 25 cm soft/ loose soil complete all as specified and as directed.
Removing excavated material n exc 50 m and depositing where directed at level not exc 1.5m above starting point,soil
Demolition/taking down PVC/CI drain/Rain Water Pipe under floor or wall of internal dia 75/100 mm, set in cement mortar/ Bricket (working height not exc. 10 mtrs ) complete incl fittings.
S&F PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls 110 mm bore complete.
S&F PVC (SWR) pipes, single socketed, in any length with rubber ring joints, laid in trenches or in floors, 75 mm bore complete.
S&F PVC (SWR) pipes, single socketed, in any length with rubber ring joints, laid in trenches or in floors, 110 mm bore complete.
S&F PVC (SWR) bends any radius, 75 mm bore, provided with access door complete.
S&F PVC (SWR) bends any radius, 110 mm bore, provided with access door complete.
S&F PVC (SWR) vent cowl, 110 mm bore complete.
Cutting pipe in any position and blocking up to end with cement concrete 1:2:4 type B-1 for a depth of at least 30cm from the cut made for 150mm dia pipe.
M & L for salt glazed stone ware drain pipes laid in trenches and jointed as specified Gde A 150mm internal dia meter of pipe incl Bends and taper bends,any radius Single 'Y' junctions
M&L Salt glazed stoneware Bend for drain pipe 150mm radius.
M&L for Salt glazed stoneware Y for drain pipe 150mm radius.
Cutting into existing manholes for connecting new drains, making good to pipe and rendering , cutting out existing benching for and forming branch channel (Half round or 3/4 section) in Cement concrete 1:2:4 type B-1 smooth finished, and reforming benching as required internal diameter of pipe 100-200mm.
M&L for plain cement concrete aggregate bed to drain pipe , 150mm dia including packing under and haunching against the side of pipe after they are laid and tested in cement concrete (1;4:8) type D-2 using 40 mm graded stone aggregate.
M&L for 75 mm thick PCC M-10 type C-2 as in plinth protection finished even and fair without using extra cement including necessary form work and joint cutting complete all as specified and directed.
Spreading and levelling of soil in layers n exc. 25 cm thick with well ramming including watering as required for filling under floor complete all as specified.
Removing excavated material exc 250 m but n exc 500 m distance and depositing as directed.
M&L for PCC 1:4:8 type D2, using 40mm graded stone aggregate, as in foundation filing,sub base of floor complete all as specified and as directed
M&L for RCC M-25 (design mix) using 20 mm graded stone aggregate as in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and as directed .
M&L for RCC M-25 (design mix) using 20 mm graded stone aggregate as in Columns, pillars, piers, posts and struts complete all as specified and as directed
M&L for RCC M-25 (design mix) using 20 mm graded stone aggregate as in lintal band at any height complete all as specified and as directed
M&L for RCC M-25 (design mix) using 20 mm graded stone aggregate as in slabs supported on walls, roof beams etc and the like, complete all as specified and directed.
Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as specified and as directed
Formwork to sides of pillars, posts, struts, piers, columns and stanchions with rough finished surface complete all as specified and as directed
Form work to sides and soffit of floor or roof beams, beam haunching, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc rough finished complete all as specified and as directed
Form work to soffits of suspended slabs such as roof slab etc. n.exc. 200mm thick for fair finished surfaces of concrete complete all as specified and directed.
Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide complete all as specified and as directed
All as per item no 60 here-in-above but dia of bar 6mm to 8mm dia complete all as specified and directed.
S & F mild steel TMT bar 5 mm and over upto and incl 10mm dia as in stirrups, slabs, footing etc cut to length, bent to shape required including cranking, bending, spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with complete all as specified and as directed.
M&L for treating the bottom and sides of excavation at the rate of 5 litres of emulsion per square metre of surface area complete all as specified and directed.
M&L for treating the backfill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of vertical surface (Area of the sub structure in contact with backfill to be measured) complete all as specified and directed.
M&L for treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface complete all as specified and directed.
M&L for treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area complete all as specified and directed.
M&L for treating the soil along with external perimeter of building at the rate of 2.25 litre of emulsion per metre of the perimeter wall complete all as specified and directed.
M&L for 5 mm thick rendering in CM 1:3 on ceiling surface plaster complete all as specified and as directed.
Preparation of newly plastered surface of ceiling and applying two coats of white wash complete all as specified.
M&L for hardcore of gauge n exc. 63 mm,of broken stone deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed.
M&L for 10mm thick plaster in CM 1:3, mixed with liquid water proofing compound @ 200 ml per bag of cement when concrete is green,finished even and smooth without using extra cement complete all as specified and directed. (Note:- Liquid water proofing compound to be measured and paid separately)
Supply only Liquid water proofing compound (ISI marked) complete all as spesified and directed.
M&L for water proofing treatment to roof and edges (vertical or tapered) etc. in following sequence:- (a) Properly cleaning and drying the surface (b) Applying a coat of bituminous primer @ 0.40 ltr / Sqm conforming to IS 3384-1986 and primer shall be allowed to dry over night. (c) Laying of 3mm thick APP membrane of (non-woven polyester type) (weight not less than 3 kg per sqm) shall be done using butane torch maintaining 100mm ie overlap and 150mm end overlap,sealing all overlaps and bonded to the surface by fusing and bonding torchon method complete all as specified and directed.(Note: All water proofing work shall be done as per manufacturer instruction and under supervision of manufacturer technical representative.)
M&L for 40mm thick brick tiles laid over 20mm thick screed bed in CM 1:4 mixed with polymer based liquid water proofing additive @ 5 % by weight of cement and the joints of tiles shall be filled with CM 1:3 mixed with crude oil as per SSR-2009 (Part-I) on non assesible roof area complete all as specified and directed.
All as per ser item no 27 here-in-before but used as in skirting/dado with 10mm thick backing plaster in CM (1:4) complete all as specified and directed.
S&F powder coated anodised aluminium frame (min thickness of powder coating 50 micron) for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified.
S&F powder coated anodised aluminium door shutters (min thickness of powder coating 50 micron) aluminium section weighing 0.55 kg/m including necessary tower bolt, handle, joining cleats, glazing clips, rubber packing, anodised alumnium snap beading, screws etc. complete all as specified.
S&F powder coated anodized aluminium window and ventilator shutters (min thickness of powder coating 50 micron) side hung type without sash bars, aluminium sections weighting 0.55 Kg/ m including necessary jointing cleats, glazing clip, rubber packing, anodised aluminium fittings complete all as specified and directed.
S&F 75 mm size 4 levers aluminium mortice lock, vertical type complete all as specified.
S&F double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box,main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed complete all as specified.
S&F 5mm thick sheet glass, ordinary quality and glazing with beading in square exc 0.5 sq. m in each pane complete all as specified.
S&F 150mm long aluminium alloy floor door stopper ,fabricated type complete all as specified and directed.
S&F 20 mm dia Stainless steel curtain rod of wall thickness not less than 1mm with both side decorative brakets and fixing brakets complete all as specified and specified.
M&L for framed work such as grills, gratings, etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 290 Gde E-165 complete all as specified and directed.
All as per ser item No 02 here-in-before but except bricks and -ditto- (Re-use the old serviceable bricks obtained from ser item No.01 above).
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc.
Add or deduct for each 25 mm girth or part thereof over or under 30cm ditto as per Ser item no 134 here-in-before.
M & L for non skid joint free coloured ceramic floor tiles 7 to 8 mm thick (square/ rectangular) area of each tile exc 0.11 sqm but n exc 0.18 sqm,in floor etc set & jointed in neat cement slurry and pointed in white or coloured cement to match the surface with 15mm thick screed bed or bedding layer in CM (1:6) complete all as specified and directed.
M&L for plain cement concrete (1:3:6) type C-1 using 20 mm graded stone aggregate as in surface channel or surface drain of manholes and drains including forming and finishing with extra cement including taking down existing concrete complete all as specified and directed.
M&L plain cement concrete (1:2:4)type B-1, using 20mm graded as in manhole or drain copings and other similar works etc complete all as specified.
Material and labour for pre-cast reinforced cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate in drain or manhole cover slabs and similar work taking down RCC cover slab complete all as specified and directed.
Dismantling mild steel work of any description in any position complete all as specified and directed.
Refixing old 15 mm bore GI steel tubing and connections in new or old position (Walls, ceiling, floors, etc.) complete all as specified and as directed.
Refixing old 20 mm bore GI steel tubing and connections in new or old position (Walls, ceiling, floors, etc.) complete all as specified and as directed
Refixing old 25 mm bore GI steel tubing and connections in new or old position (Walls, ceiling, floors, etc.) complete all as specified and as directed
Refixing old 50 mm bore GI steel tubing and connections in new or old position (Walls, ceiling, floors, etc.) complete all as specified and as directed
S&F in repair rotational moulded polyethylene water storage tank of capacity 500 ltr (Cylindrical/vertical with closed top) three layer construction, ISI marked hoisted & fixed in position including dismantling of old tank and removing from site complete all as specified and directed.
S&F in repair ball/ float valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed 20mm bore minimum weight 210 gms complete all as specified and directed.
S&F in repair 20 mm bore Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.
S&F in repair 20 mm bore Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.
S & F in repair PVC connection 450 mm long, 15 mm size with brass chromium plated nuts complete all as specified.
S&F in repair CP angle stop cock/valve of 15mm bore screwed down for high pressure with crutch or butter fly handle ,screwed both end for iron pipes complete all as specified and directed..
S&F in repairs Pillar tap 15mm bore, cast copper alloy,with capstan heads, chromium plated, screwed down, high pressure with long shanks and fly nuts, screwed for iron pipe complete all as specified and directed.
S & F in repair 110 mm bore PVC (SWR), junction single, (Single T) equal or unequal complete all as specified and directed.
S & F in repair 75 mm bore PVC (SWR), junction single, (Single T) equal or unequal complete all as specified and directed.
S & F in repairs PVC (SWR) floor trap plain or multi with stainless steel grating incl joinig to waste pipe with solvent cement joint dia of outlet 75 mm bore complete all as specified and directed.
Preparation of old decorated surface of ceiling and applying one coat of white wash on ceiling complete all specified and as directed.
Preparation of old decorated surfaces of wall and applying two coats of oil bound distemper white or tinted complete all as specified and directed.
Preparation of old decorated surface of wall and applying two coats of cement base paint complete all as specified and directed.
M&L for excavating in Post holes Soft/loose soil (or similer holes)not exc 0.50 cum getting out returning filling in and ramming earth or broken rubble mixed with earth around in layers not exceeding 25 cum watering and removing surplus soil to a distance not exc 50 m and making good surface complete all as specified and directed.
M&L Pre -Painted galvalume Alumenium zinc coating GI based corrugated steel sheet 0.50mm Thicness of any colour having aTensile strength of 550 MPA as in roof covering fixed with 'L' type or 'J' type or cranked hook bolts All As specified &directed by Eng-IN-Charge
M&L Pre -Painted galvalume Alumenium zinc coating GI based plain steel sheet 0.50mm Thicness of any colour having aTensile strength of 550 MPA as in roof covering fixed with 'L' type or 'J' type or cranked hook bolts All As specified &directed by Engr-In-Charge
S&F Framed bracket of angle or Tee with Web and Flange cut to shape drilled and countersunk for screw including bending and welding angles As necessary gusset plates riveting etc n exc 10 kg each brakets confirming to Fe 290 gde-E-165 complete all as specified and directed.
S & F Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-24 complete all as specified and directed.
M&L for preparation of new or previously untreated surfaces of any description, over 10cm in width or girth, not otherwise described and applying two coat of aluminium paint, complete all as specified and directed.
M & L for 10 mm thick plastering in CM (1:6) and prepared to receive wall tiles and M & L Non-skid coloured Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.18 Sqm but not exceeding 0.38 Sqm, as in skirting, dado.set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed.
Mild steel pressed handles 150 mm oval type, stove enamlled black complete all as specified and directed.
S & F small fittings such as shaped door and window stops and the like inclding all necessary labours, articles n.exc. 200 Cu Cm each complete all as specified and directed.
MS sliding door bolts, 250 mm long plate type, stove enamlled black, with bright bolt not less than 12mm dia with & including a minimum of 6 bolts & nuts, four on bolt plate & two on staple plate & fixed complete all as specified and directed.
S & F MS barrel tower bolts, stove enamlled black, with bright bolt& fixed. 150mm long.
S & F 2nd class hard wood 40 mm thick Plain framed,factory made panelled shutter (two panels) with lock rail and panel of 9mm BWP comercial ply or 12mm vennered particle board with comercial veneering on both faces. The size of rail & stile as per IS: 1003, klin seasoned & chemically pressure treated.
Supply only MS Butt hinges medium weight 100 mm size
M & L Continuous brick edging 75mm wide with brick laid on end vertically with fly ash old brick complete all as specified and directed.
S & F PVC pipe single socketed 110 mm dia in any length, jointing with cement solvent solution, fixed to walls complete all as specified and directed.
M & L two coats of cement base paint on newly plastered surface of walls incl preparation the surface of walls (External) complete all as specified and directed.
M & L for RCC (1:2:4) type B-1 as in lintels, beam etc. over 1.5 mtr span.
M & L for rendering 15mm thick in CM(1:6) on other than fair faces of brick work finishing even & smooth without using extra cement.
M & L cement concrete 100 mm thick type C2 1:3:6 (40 mm graded aggregate) as in floor sub base.
M&L cement concrete in foundation filling and mass concrete type B2 1:2:4 (40mm graded aggregate) complete all as specified and directed.
Taking down carefully point wiring of any type complete for light, fan socket or power point with fittings & fixtures such as ceiling rose, electric fittings, holders, switches, sockets, regulators, wooden batten, surface conduit/casing caping/conceal etc. removing materials including accessories for taking credit and making good disturbed surface to match the existing complete all as specified & directed.
M&L for point wiring (concealed type) complete with FRLS PVC insulated, unsheathed stranded copper conductor of nominal area 1.5 Sqmm( 22/0.30 or 30/0.25), 1100 volts grade, along with one single run of same size and type of copper wire as continuous earth wire to common earth dolly in and including cutting/chasing on brick wall not exc. 10 cm girth (excluding ceiling surface) and supply and fixing PVC conduit pipe medium grade of nominal size 20 mm dia along with connected fittings/junction boxes using new MS sunk terminal boxes of thickness not less 1.22 mm, new 3 mm thick laminated sheet cover with brass screw and cup washers with all accessories and making good to disturbed surface with cement mortar ratio of 1:3 and treated surface with existing white/colour wash/distemper etc to match with existing surface complete all as specified and directed and suitable for the following: -
(a) One light/fan/bell point controlled by one switch
(b) One point for socket outlet 5 amps on independent board but not below the switch board in same vertical plane
(c) One point for socket outlet 5 amp same board
(d) One 3/5 pin socket outlet, 6 Amp on the same board with other switches
(e) One 3 pin socket outlet, 6 Amp on “independent board” but below the switch board of the light point in same vertical plane. Note : Socket Outlet point provided beside to switch board on same wall will be measured as below the switch board
(f) One 3/5 pin socket outlet, 6 Amp on “independent board”
All as per ser item No. 179 here in before but point wiring using 2.5 sq mm or 36/0.30 or 80/0.20 or 50/0.25 (Nominal area) FRLS PVC insulated unsheathed copper conductor 1100 volts for one 3/6 pin socket outlet ,suitable for 16 amps “ independent board”.
All as per ser item No. 179 here in before but point wiring using 4.0 sq mm or 36/0.30 or 80/0.20 or 50/0.25 (Nominal area) FRLS PVC insulated unsheathed copper conductor 1100 volts for one 3/6 pin socket outlet, suitable for AC point “ independent board”.
Supply & fixing ISI marked switch piano flush button type, single pole, one way, 6 Amps
Supply & fixing socket out let 6 pin, 6 Amps flush type
Supply & Fixing switch socket combination multipurpose 2 in 1, 6 pin, 6 and 16 Amp
Supply & fixing ceiling rose 3 pin/PVC/ polycarbonate
One 3 pin 15 Amp socket outlet point controlled by one switch using 2.5 sqmm copper conductor cable with continuous earth wire of 2.5 sqmm copper conductor on independent board.
S&F in repair ceiling rose surface type bakelite 65x50mm three terminal complete all as specified and directed.
S&F angle/batten type holder insulated body with back plate suitable for light point complete all as specified and directed.
S&F switch piano flush type, 5 amps, 230V AC,single pole, one way complete all as specified & directed.
S&F socket out let 2-in-1, 3 pin, 5 amp flush type complete all as specified & directed.
S&F switch piano flush type 16 amps, 230V AC single pole one way complete all as specified & directed.
S&F socket out let 2-in-1, 3 pin, 5 & 15 amp flush type complete all as specified & directed.
S&F fan regulator, 5 stepped, electronic type, single phase, 80 watt, socket size incl connection complete complete all as specified & directed.
S&F in replacement of sheet metal enclosure single pole and neutral enclosure with a two pin and earth plug and socket along with one MCB, single pole of current rating 20 amps, C series 240 volts AC complete all as specified & directed.
Taking down main switches fuse unit, MCB/Kit kat distribution board with steel enclosure along with MCB’s /Kit kat fuse of any amps/ways including wooden board or from steel board and making good disturbed surfaces complete all as specified & directed.
S&F sheet metal enclosure for MCB's 240 volt 4 way single pole and neutral with 200 amps rated busbar double door on wall with and including suitable flat iron clamps duly grouted/ fixed flush in the wall complete all as specified and directed.
S&F sheet metal enclosure for MCB's 240 volt 8 way single pole and neutral with 200 amps rated busbar, double door on wall with and including suitable flat iron clamps duly grouted/ fixed flush in the wall complete all as specified and directed.
S&F MCB single pole, 6 to 32 amps rating, 240 volts, 'C' series, 10 KA breaking capacity & making connection complete all as specified and directed.
S&F MCB single pole & Neutral, 32 amps rating, 240 volts, 'C' series, 10 KA breaking capacity & making connection complete all as specified and directed.
S&F MCB single pole & neutral 40/63 amp, 240 volts, 'C' series, 10 KA breaking capacity & making connection complete all as specified and directed.
Taking down carefully sub main wiring of any nos of wire and size with earth wire on wooden batten/surface conduit/casing caping complete with its all accessories complete all as specified & directed.
M&L for two single core (submain) FRLS PVC insulated cable and one single core green PVC insulated copper conductor earth continuity cable as mentioned below is drawn in and including non metallic, medium duty, rigid PVC conduit not less than 20 mm dia concealed in wall including all conduit and fixing accessories including cutting chases & making good to disturbed surfaces with cement mortar ratio of 1:4 and colour wash complete all as directed. Note :- (I) The cost for cutting, chases required shall deemed to be included in the quoted unit rate. (II) Two run of submain wire, one run of earth wire and one run of PVC conduit shall be measured one RM
(a) 2x4.0 sq. mm + 1x2.5 sq. mm earth wire
(b ) 2x6.0 sq. mm + 1x4.0 sq. mm earth wire
Cutting & Chasing required on brick wall, exceeding 20 CM girth and making good to disturbed surface with cement mortar 1:3 including facing / finishing where as required to match with existing surfaces to recess the MCB DB/sheet steel enclousure complete all as specified and directed.
Cutting & chasing required on brick wall not exceeding 10 CM girth for concealed conduit wiring and for GI earth wire including making good to disturbed surface with cement mortar 1:3 and distemper / colour wash to match with existing surfaces including facing / finishing where as required complete in all respect as specified and directed.
Supply & fixing in replacement of worn out/rusted sunken box with pressed MS/GI steel terminal boxes of depth not less than 50 mm, flush type of thickness lot less than 1.22 mm of following size alongwith new 3.0 mm thick plastic laminated sheet cover of suitable size including cutting/drilling hole and fixing switches, sockets, fan regulator etc as removed from old sheet and fitted with cadmium plated screw washer and making good to disturbed surface with cement mortar complete in all respect as specified and directed.
(i)100mm x 100mm
(ii) 175mm x 100mm
Taking down existing old /worn out tube/CFL/bulk head/sketch light fittings of indoor type fixed on wall of any type/size with its all accessories including lamp complete all as specified & directed
Supply & fixing surface /wall mounted light fitting in CRCA powder coated white housing with pre wired suitable for single T8 LED tube along with supply and fixing one number LED tube in polycarbonate housing of nominal wattage - 18 Watt, Lumen out put - 2100 Lm, Colour Temp - 6500 Kelvin, Size & Length - G13/ T8/ 4 Feet with integral/in built driver, having short circuit and surge protection including making connection with two core PVC insulated, sheathed copper conductor cable of size 23/0.0076 complete all as specified and directed. Cat Part No for batten:- REGALBATTENT8UPTO1X18WDSBSWH of make Havells 'or' IGP161LT8-16 of make Crompton 'or' TMC501 P 1xT-LED 22W P3241 of make Philips or its equivalent as approved Cat Part No for Tubelight:- PHOTANULTRA2.01213T8SSTL18WLED865SPC of make Havells 'or' LTT8-20 of make Crompton 'or' MAS LEDtube 1200MM 18W865 T8 I-2100 lm of make Philips or its equivalent as approved
Supply & fixing energy efficient LED light of 10 Watt of length - 02 Feet long having minimum 1150 Lumen output, wide voltage protection range 140-270 Volt AC housed in extruded aluminum housing (enhances safety) with high quality polycarbonate diffuser including making connection with two core PVC insulated, sheathed copper conductor cable of size 23/0.0076 complete all as specified and directed. Cat part No: -LUMILINEPLUSSBS10WLED865SPCSS of make Havells 'or' BN 021 LED10S- 6500 PSU GR S1 of make Philips 'or' LDL-10-WW of make Crompton or its equivalent as approved
Supply and fix electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc.as specified or directed by Engr-in- Charge.
Supply, fixing, connecting & testing heavy duty exhaust fan of 300 mm sweep, single phase, 230 Volt AV, 1400 RPM, Input Wattage - 145 Watt, Free air Flow - 3700 CuM/Hr tolerance on rating as per IS 2312/1967 including supply and fixing louver & shutter, connecting with FR PVC insulated & PVC sheathed round flexible copper conductor wire of size 23/0.0076 in three core of length not more than 1.0 Mtr complete in all respect as directed. Model - Turbo Force SP of make - Havells or as approved
M &L for Earthing complete with GI earth plate electrode 600x600x6mm thick buried directly in ground (Earth pit not less than 2.25M deep below normal ground level) with top edge of the plate not less than 1.5m below normal GL. Connected to galvanized earth lead wire 4mm dia by means of nut, bolt, check nut and washers including necessary excavation and earth work in soft/loose soil, GI protection pipe light grade 15mm bore for protecting the GI wire mesh funnel alternate layer of charcoal dust, and salt PCC pit 1:3:6 type C1 using 20mm graded stone aggregate and 50mm thick RCC 1:2:4 type BO using 20mm graded stone aggregate cover re-inforced with 8 mm dia MS TMT bars 80mm C/C both ways complete all as specified and shown in Electrical plate No.3 SSR part-1 and connected to the earth point and testing complete all as specified and directed.
Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete.
S&F (in replacement) bracket for street light made out of 40 mm bore GI pipe medium grade not less than 1.2 mtr length bent at 120 degree to shape fixed on pole/wall with and including 50x6mm FI clamps = 02 Nos with nut bolts, washers including painting of clamps with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
Supply & fixing in replacement of existing worn out DB with single phase & neutral MCB Distribution Box of 8 Way, double door of protection grade IP 43 in fine powder coated, matt finish with best CRCA sheet, fitted with shrouded neutral, insulated pin type copper bus bar, Din rail, earth bar confirming to IS 13032 & 8623 complete all as specified and directed.
Supply & fixing of MS terminal box fixed for geyser/AC by sheet steel enclosure in single pole and neutral fitted with two pin and earth plug and socket of current rating 20 amps complete with fixing one single pole MCB , 'C' series of current rating 25 amp including cutting, chasing in wall to recess the same and making good complete all as specified and directed.
Supply & fixing MCB with high rating MCB Triple pole, 100 Amps 240 volts AC,'C' Series, conforming to IS 8828/IEC 60898-1 including making connections with copper lugs, testing as required complete all as specified and directed. Make - Havells/Indo Asian/Schneider (Electric)/HPL/Siemens /L&T or as approved.
Supply & fixing in replacement of MCB double pole , 40 Amps 240 volts AC , 'C' Series, conforming to IS 8828/IEC 60898-1 including making connections with copper lugs, testing as required complete all as specified and directed.
Supply & fixing in replacement of worn out MCB with MCB SP, 06 to 32 Amps 240 volts, 'C' Series, ISI marked and conforming to IS 8828/IEC 60898-1 including making connections with copper lugs, testing as required complete all as specified and directed.
Supply & fixing ceiling fan of size 1200 mm sweep, conforming to IS : 374, 5 Star rated, nominal wattage -50 Watt (± 5 %) , speed - 320 to 380 RPM, Air dilivery - 215 to 225 Cu Mtr/Min including accessories complete suitable for operating voltage 230 Volt AC connecting with FR PVC insulated & PVC sheathed round flexible copper conductor wire of size not less than 23/0.0076 in three core of length not more than 0.5 Mtr including taking down the existing old ceiling fan ( antique model ) and depositing the same to E/M store yard complete in all respect as specified and directed. Model - ES 50 Premium of make - Havells, or Model - Aura Plus of make - Crompton, or Model - Joan of make Orient, or its equivalent model in Khaitan/Usha/Almonard or as approved
Supply & fixing in replacement down rod made by mild steel 'light grade' 15mm dia pipe of length 3.5 Mtr to 4.5 Mtr with making split holes, cut or threads at both end of pipe as required for hanging of C/fan including painting of rod with two coats of synthetic enamel white paint over one coat of primer complete all as specified and directed.
M&L for replacement of sub main wiring with 2 x 4.0 Sqmm + 1 x 4.0 Sqmm earth wire , FRLS PVC insulated unsheathed flexible copper conductor (Multistrands), single core , 1100 Volts grade along with FRLS PVC insulated unsheathed flexible copper conductor (Multistrands) in green colour as continuous earth wire conforming to IS 694 with latest amendments and ISI marked, drawing in recessed/surface PVC conduct and making incoming / outgoing electric connections by using required size copper lugs / thimbles, making good to disturbed surface to match with existing including removal of existing old complete in all respect as specified and directed.
M&L for replacement of sub main wiring with two run of 6.0 Sqmm or 84/0.30 FR PVC insulated unsheathed flexible copper conductor (Multistrands), single core , 1100 Volts grade and one run of 6.0 Sqmm FR PVC insulated unsheathed (In Green Colour), flexible copper conductor (Multistrands) for continuous earthing conforming to IS 694 with latest amendments and ISI marked, drawing in surface/recessed PVC conduct and connecting incoming / outgoing electric connections by using required size copper lugs / thimbles and making good to disturbed surface to match with existing including removal of existing old complete in all respect as specified and directed.
S&F LED light fitting 10 Watt bulkhead luminaires in high pressure die cast aluminium housing, lumen out put - 700 Lm, colour Temp - 6500 K having Ingress protection - IP 65 fpr dust, water & IK 08 for external impact including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. Cat Part No - WT140 LED7S NW PSU S1 PC; Vistaglow of make - Philips 'or' LBHP-10-CDL of make Crompton 'or' LW07-11-XXX-57-XX of make Wipro or its equivalent as approved complete all as specified and directed.
M&L for earthing as per IS:3043 with galvanized steel earth plate electrode 600 x 600 x 6.0 mm thick buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metre below normal ground level connected to galvanized iron wire 4 mm dia (8 SWG) as earthing lead protected by GI pipe medium grade 15 mm bore for protection of GI earth wire and 20 mm bore GI pipe medium grade for watering with alternate layers of charcoal /coke and salt including all accessories like nut, bolts, reducer, nipple, wire meshed/screened funnel and making brick masonry finished chamber of internal size 300 mm x 300 mm x 300 mm with concrete base, covered with a Cast Iron hinged cover resting over the Cast Iron frame painted with black bitumastic paint which shall be embedded in the block masonry including excavation works, refilling, connected to main switch/MCB DB for feeding the electric supply to domestic quarters compete all as specified as shown in electricall plateNo. 3 of SSR Part-I and testing of earth resistance as required.
Supply, fixing & connecting to electrical system & testing of LT distribution panel board CPRI approved make ,cubical type for out door use, made out of 3.15 mm thick CRCA sheet factory made, totally enclosed of size not less that 1000x900x500mm and supported with 4 Nos MS Angle legs , duly painted with two coats of powder coated paint over one coat of red oxide primer effectively PVC gaket and sealed mounted on PCC blocks double door type with locking arragnedment with handle at front and openable at front &back bothe side with required hinges heavy duty, compartemtalised suitably including provision for tapping incoming & outgoing electric connections with suitable size of aluminium lugs glands and comprising of the following accessories :- (a) High conductivity aluminium busbar (Set of 4 strips), 4 Nos TPN of 400 amps rating (RYB) for phase and 1 No for neutral mounted on DMC support with heat shrink sleeve-1 Set. (b) Phase indication lamp, LED type(set of 3) -1 Set (c) Ammeter anolog type having measuring range (0-300) Amps with CTs etc including rotary switch to measure load of each phase : L&T/Seimens. (d) Replacement of volt meter having measuring range (0-500) volt with rotary switch to measure voltage of phase R.Y.B make : L&T/AE (e)MCCB 4 Pole 315 Amp 415 volt ,36 KA breaking capacity with spreader bothe side, as Incomming cotrol device : 01 Nos.( Make : L&T (AU series) /ABB/Schnieder) (f) MCCB 4 pole 160 Amp 415 volt rating & breaking capacity 25 KA with spreader at bothe side. : 3 Nos ( Make : L&T (AU series) /ABB/Schnieder) (g) Grouting of panel including earth work as required PCC (1:3:6) type D-2 using 20 mm gradeded stone & plastering with (1:4 )cement sand etc complete
Supply & fixing Vertical type DB with Three phase & neutral MCB Distribution Box of 4 Way, double door of protection grade IP 43 in fine powder coated, matt finish with best CRCA sheet, fitted with shrouded neutral, insulated pin type copper bus bar, Din rail, earth bar confirming to IS 13032 & 8623 complete all as specified and directed. Make:Indo asian/ Havells/Hager or as approved
Supply & fixing MCB with high rating MCCB pole, 160 Amps 240 volts AC,'C' Series, conforming to IS 8828/IEC 60898-1 including making connections with copper lugs, testing as required complete all as specified and directed. Make - Havells/Indo Asian/Schneider (Electric)/HPL/Siemens /L&T or as approved.
Supply & laying cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor using lugs bothe end of cable& wrapping pvc tape over XLPE insulation cable and testing complete all as directed for Following size:(a) 95 Sq mm 3.5 core
Excavation in trenches in soft/ loose soil n.exc 1.5 m wide and n.exc. 1.5 mtr deep and getting out and laying LT UG Cable complete all as specified and directed .
Supply and laying sub class 'B' brick old size laid flat in trenches across the length for protection of cable as cable cover complete all as specified and directed .
M& L for sand cushioning in trenches for protection of under ground cable provided in layers of sand as 8 cm before laying the cable and 15 cm deep after laying cable complete all as specified and directed.
Excavating in trenches n. exc 1.5 m width and n. exc 1.5 m in depth including forming of bottom surface to required level or slope for laying CI/GI pipe in soft/loose soil complete all as specified and as directed.
M/S PRAGATEE ENTERPRISES
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .