Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.0 LAccepted-AOC LOONPURIA GAON AT ROAD PANITOLA PO PANITOLA 786183 DIST TINSUKIA ASSAM | TINSUKIA | ASSAM | 786183 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹10.4 L+₹46,740 (4.69%)Rejected-Finance 16 BAITHAKKHANA ROAD 16 BAITHAKKHANA ROAD SEALDAH BAITHAKKHANA ROAD SEALDAH BAITHAKKHANA ROAD SEALDAH KOLKATA | L2 | Rejected-Finance OTHER THAN LOWEST | |
| 3 | L3₹12.4 L+₹2.5 L (24.7%)Rejected-Finance AT MAIN ROAD DANDAI PO PS DANDAI DIST GARHWA | LATEHAR | JHARKHAND | 822112 | L3 | Rejected-Finance OTHER THAN LOWEST | |
| 4 | L4₹13.3 L+₹3.3 L (33.3%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN LOWEST | |
| 5 | Rejected-Technical | - | Rejected-Technical NOT MEETING ELIGIBILITY CRITERIA |
Tender Value
₹14.3 L
EMD Value
₹28,600
Closing Date
31 May 2021, 6:00 pmClosed
COMMANDER WORKS ENGINEER, DINJAN
COMMANDER WORKS ENGINEER, DINJAN
PROVN OF ONE STANDBY VCB WITH CONNECTED ACCESSORIES FOR GE DINJAN AT DINJAN MIL STN
2021_MES_440391_1
83067E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE DINJAN
AS PER TENDER
7 documents required · 7 mandatory
₹500
Yes
GE DINJAN
₹28,600
Yes
1 Jul 2021
4 May 2021
1 Jun 2021
4 May 2021
31 May 2021
19 May 2021
5 May 2021 - 12 May 2021
Amount
Excavating in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. or for cable laying or pole foundation etc or not exceeding 10 sqm on plan and not exceeding 1.5 m in depth and getting out in soft/ loose soil complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft/ loose/ hard/ dense soil complete all as specified and as directed.
Removing excavated material (soils) not exceeding 50 m and depositing where directed at a level n exc. 1.5 m above the starting point
Supply & laying unreinforced precast concrete cable cover class HVP type 1, with peak shape, dimension 300 mm X 180 mm X 40 mm and 65 mm peak thickness as per IS 5820: 1970 complete all as specified and directed.
M & L for sand filling under floors or in foundations including watering and consolidation complete all as specified and as directed.
Supply, laying and testing cross linked polyethylene (XLPE) insulated, PVC sheathed cables for working voltages 6.35 kV/ 11 kV, three phase, earthed system, 3 core, screened, armoured power cable, 95 sqmm of nominal area of conductor, aluminium conductor, ISI marked as per IS 7098 (Part-II): 2011 laid in trenches or under floors making all connections with necessary glands lugs bushing complete all as specified and as directed.
S & F XLPE cable end termination, cold shrinkable, outdoor type, suitable for voltage 6.35 kV/ 11 kV (Earthed), 3 core 95 sqmm complete all as specified and as directed.
S & F nominal 2.0 mm + 10% thick insulating mats made of elastomer conforming to IS-15652: 2006 and meeting the requirement of IS- 5216 (Part -1 & 2) IS 8437, IEC-479 Pub -1 along with suitable adhesive/ homebound, PV resin water proofing compound and sealing material as per recommendation of Annex 'A’, Clause- 'C’ of IS- 15652 and suitable for class - A upto 3.3 kV complete all as specified and as directed.
Supply and fixing Electric shock treatment chart colour printed in HINDI & ENGLISH as per BIS 1986 of standard size 24'' x 18'' complete as per IS Specs with necessary fixing arrangements complete all as specified and directed.
M & L for earthing complete with galvanised steel plate earth electrode 600 mm X 600 mm X 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to earthing lead of 32 mm X 6 mm galvanised mild steel strip by means of bolts, nuts, check nuts and washers of galvanised iron from earth plate to test point upto 7.5 metre including all as shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete chamber in cement concrete M15 (Nominal Mix) using 20 mm nominal size coarse aggregate, precast RCC cover slab in cement concrete M15 (Nominal mix) using 20 mm nominal size coarse aggregate of size 40 cm X 40 cm X 5 cm reinforced with 8 mm dia TMT bars @ 150 mm c/c with one handle for lifting made out of 8 mm dia bar, GI funnel, GI wire mesh filter, 20 mm dia GI pipe medium grade for watering, 40 mm dia GI pipe medium grade for protection of earthing lead, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil/ strata and testing complete all as specified and as directed by the Engineer-in-charge.
M/s HALDER ENTERPRISE
ms singh construction
satyabhama and co
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .