Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹104.7 CrAccepted-AOC C 2488 SUSHANT LOK PHASE 1 GURGAON 122001 HARYANA | GURUGRAM | HARYANA | 122001 | ₹104.7 Cr | L1 | Accepted-AOC Lowest tenderer |
| 2 | L2₹111.5 CrRejected-Finance | ₹111.5 Cr | L2 | Rejected-Finance Not being lowest |
| 3 | L3₹113.1 CrRejected-Finance | ₹113.1 Cr | L3 | Rejected-Finance Not being lowest |
| 4 | L4₹124.9 CrRejected-Finance 201 202 2ND FLOOR FITWELL HOUSE OPP HOME TOWN LBS MARG VIKHROLI W MUMBAI 400083 | MUMBAI SUBURBAN | MAHARASHTRA | 400083 | ₹124.9 Cr | L4 | Rejected-Finance Not being lowest |
| 5 | L5₹127.7 CrRejected-Finance C 102 ANSAL PLAZA HUDCO PLACE KHELGAON MARG NEAR SOUTH EXTENSION NEW DELHI 110 049 | ₹127.7 Cr | L5 | Rejected-Finance Not being lowest |
Tender Value
₹130 Cr
EMD Value
₹65 L
Closing Date
11 Feb 2025, 6:00 pmClosed
DG MAP
HQ DG MAP E IN C BRANCH KASHMIR HOUSE RAJAJI MARG NEW DELHI 110011
COMPLETION OF BALANCE WORK FOR CONSTRUCTION OF DWELLING UNITS INCLUDING ALLIED SERVICES FOR OFFICERS MCPOS SAILOR JWO AIRMEN AT MUMBAI NAVY AND AIRFORCE
2024_MES_682525_1
81985 MUMBAI NAVY AF
Open Tender
Civil Works
548 days
COLABA MANKHURD KALINA AND SANTACRUZ
AS PER TENDER DOCUMENTS
9 documents required · 9 mandatory
₹3,000
DG MAP
₹65 L
DG MAP NEW DELHI
6 Jun 2025
6 Nov 2024
13 Feb 2025
6 Nov 2024
11 Feb 2025
29 Jan 2025
7 Nov 2024 - 20 Nov 2024
24 Jan 2025
Amount
Completion of balance work for Construction of block of 37 DUs for CPO/MCPO (Stilt + 10, 4 DUs on each Floor and 1 DU on top floor) RCC framed structure, showing all structure including garages at ground floor, main staircase, fire scape staircase, perspect sheet i.e covering to open sky portion, lift lobby, machine room, shafts, plinth protection, steps, ramps, plat forms, balconies and all fixture fitments, built in furniture, fire fighting water tank overhead, services water tanks, loft tank etc complete all as specified and shown on drawings. scope of work including all works above piles including pile caps, connected beams and above including PCC below pile cap, excluding piling work at Colaba Mumbai. (NAVY)
Completion of balance work for Construction of block of 63 DUs for CPO/MCPO (Stilt + 16, 4 DUs on each Floor and 3 DUs on top floor) RCC framed structure, showing all structure including garages at ground floor, main staircase, fire scape staircase, perspect sheet i.e covering to open sky portion, lift lobby, machine room, shafts, plinth protection, steps, ramps, plat forms, balconies and all fixture fitments, built in furniture, fire fighting, water tank overhead services water tanks, loft tank etc complete all as specified and shown on drawings. scope of work including all works above piles including pile caps, connected beams and above including PCC below pile cap, excluding piling work at Munkhurd Mumbai. (NAVY)
Completion of balance work for Construction of block of 54 DUs for Sailors (Stilt + 14, 4 DUs on each Floor and 2 DUs on top floor) RCC framed structure, showing all structure including garages at ground floor, main staircase, fire scape staircase, perspect sheet i.e covering to open sky portion, lift lobby, machine room, shafts, plinth protection, steps, ramps, plat forms, balconies and all fixture fitments, built in furniture, fire fighting, water tank, overhead services water tanks, loft tank etc complete all as specified and shown on drawings. scope of work including all works above piles including pile caps, connected beams and above including PCC below pile cap, excluding piling work at Colaba Mumbai. (NAVY)
Completion of balance work for Construction of block of 46 DUs for Sailors (Stilt + 12, 4 DUs on each Floor and 2 DUs on top floor) RCC framed structure, showing all structure including garages at ground floor, main staircase, fire scape staircase, perspect sheet i.e covering to open sky portion lift lobby, machine room, shafts, plinth protection, steps, ramps, plat forms, balconies and all fixture fitments, built in furniture, fire fighting, water tank overhead services water tanks, loft tank etc complete all as specified and shown on drawings. scope of work including all works above piles including pile caps, connected beams and above including PCC below pile cap, excluding piling work at Mankhurd Mumbai. (NAVY)
Completion of balance work forConstruction of block of 6 DUs for Sqn Ldr three stroyed construction (Ground + 02 Storeyed) RCC framed structure including car garages, covered stair case, servant quarters, balconies, loft passages, built in furniture, plinth protection water storage tanks including staging complete including foundations all as specified and shown on drawings at Kalina, Mumbai. (AIRFORCE)
Completion of balance work for Construction of block of 5 DUs for Sqn Ldr three stroyed construction (G+2 storey 2 DUs on Ground Floor, 02 DUs on First Floor and 1 DU on top floor) RCC framed structure showing all structure including car garages, covered stair case, servant quarters, balconies, loft passages, built in furniture , plinth protection water storage tanks including staging complete including foundations all as specified and shown on drawings at Kalina, Mumbai. (AIRFORCE)
Demolition of Block of 20 DUs (S+5) for JWO (A) which was constructed upto S+3 level with RCC framed structure showing all structure including car & scooter garages at ground floor , main stair case, fire escape stair case, perspect sheet i.e is covering to open sky portion lift , lobby , machine room, shaft , steps , ramps , platform, balconies and all fixture fitments, loft tank, RCC foundation (Footing ,beam & columns) and complete removing excavated and demolished material outside MD LAND complete as specified and dircted.
Demolition of Block of 20 DUs (S+5) for JWO (A) which was constructed upto S+3 level with RCC framed structure showing all structure including car & scooter garages atground floor , main stair case, fire escape stair case, perspect sheet i.e is covering to open sky portion lift , lobby , machine room, shaft , steps , ramps , platform, balconies and all fixture fitments, loft tank, RCC foundation (Footing ,beam & columns) and complete removing excavated and demolished material outside MD LAND complete as specified and dircted.
Demolition of Block of 20 DUs (S+5) for Airmen which was constructed upto S+5 level with RCC framed structure showing all structure including car & scooter garages at ground floor , main stair case, fire escape stair case, perspect sheet i.e is covering to open sky portion lift , lobby , machine room, shaft , steps , ramps , platform, balconies and all fixture fitments, fire fighting water tank, Over head service water tank, loft tank, RCC foundation (Footing ,beam & columns) and complete removing excavated and demolished material outside MD LAND complete as specified and dircted.
Demolition of Block of 20DUs (S+5) for Airmen which was constructed upto S+5 level with RCC framed structure showing all structure including car & scooter garages atground floor , main stair case, fire escape stair case, perspect sheet i.e is covering to open sky portion, lift , lobby , machine room, shaft , steps , ramps , platform, balconies and all fixture fitments, fire fighting water tank, Over head service water tank, loft tank, RCC foundation (Footing ,beam & columns) and complete removing excavated and demolished material outside MD LAND complete as specified and dircted.
Demolition of Block of 14 DUs (Half Stilt+ 3 ) for Airmen which was constructed upto Half Stilt+ 3 level with RCC framed structure showing all structure including car & scooter garages at ground floor , main stair case, fire escape stair case, perspect sheet i.e is covering to open sky portion, lift , lobby , machine room, shaft , steps , ramps , platform, balconies and all fixture fitments, fire fighting water tank, lofttank, RCC foundation (Footing ,beam & columns) and complete removing excavated and demolished material outside MD LAND complete as specified and dircted. Note for Items 1.07 to 1.11:- The contractor has to visit the site before quoting their rates for demolition. The description in brief for guidance of contractor, however contractor have to carryout the complete demolition of existing buildings and removal of materials.
Construction of block of 20 DUs for JWO (Stilt + 5, 4DUs on each floor) RCC framed structure showing all structure including car and Scooter garages at ground floor, main stair case, fire escape stair case, perspect sheet i.e. covering to open sky portion, lift lobby machine room, shafts, plinth protection, steps, ramps, platforms, balconies and all fixture fitments, built in furniture, Fire Fighting water tank, overhead services water tanks, loft tank etc complete including foundations all as specified and shown on drawings at Wakola Santacruz (Mumbai) (AIRFORCE)
Construction of block of 20 DUs for JWO (Stilt + 5, 4DUs on each floor) RCC framed structure showing all structure including car and Scooter garages at ground floor, main stair case, fire escape stair case, perspect sheet i.e. convering to open sky portion, lift lobby machine room, shafts, plinth protection, steps, ramps, platforms, balconies and all fixture fitments, built in furniture, Fire Fighting water tank, overhead services water tanks, loft tank etc complete including foundations all as specirfied and shown on drawings at Wakola Santacruz (Mumbai) (AIRFORCE)
Construction of block of 20 DUs for Airmen (Stilt + 5, 4DUs on each floor) RCC framed structure, showing all structure including Scooter garages at ground floor, main stair case, fire escape stair case, perspect sheet i.e. covering to open sky portion, lift lobby machine room, shafts, plinth protection, steps, ramps, platforms, balconies and all fixture fitments, built in furniture, Fire Fighting water tank, overhead services water tanks, loft tank etc complete including foundations all as specified and shown on drawings at Wakola Santacruz (Mumbai) (AIRFORCE)
Construction of block of 20 DUs for Airmen (Stilt + 5, 4DUs on each floor) RCC framed structure, showing all structure including Scooter garages at ground floor, main stair case, fire escape stair case, perspect sheet i.e. covering to open sky portion, lift lobby machine room, shafts, plinth protection, steps, ramps, platforms, balconies and all fixture fitments, built in furniture, Fire Fighting water tank, overhead services water tanks, loft tank etc complete including foundations all as specified and shown on drawings at Wakola Santacruz (Mumbai) (AIRFORCE)
Construction of block of 14 DUs for Airmen (Half Stilt + 3, 2DUs on Ground floor and 4 DUs on each floor) RCC framed structure, showing all structure including Scooter garages in half stilt, covered stair case, balconies, plinth protection, steps, ramps, platforms, built in furniture, Water storage tanks inclding staging etc complete including foundations all as specified and shown on drawings at Wakola Santacruz (Mumbai) (AIRFORCE)
Construction of block of 2 Car garages for Sqn Ldr with RCC framed structure including foundations, RCC roof, RCC shelves ramps etc complete all as specified and shown on drawings at Kalina, Mumbai
Construction of block of 1 Car garage for Sqn Ldr with RCC framed structure including foundations, RCC roof, RCC shelves ramps etc complete all as specified and shown on drawings at Kalina, Mumbai
Construction of block of 2 Car garages for JWO with RCC framed structure including foundations RCC roof, RCC shelves ramps etc complete all as specified and shown on drawings at Santacruz , Mumbai
Construction of block of 12 Car garages for MCPO with RCC framed structure including foundations RCC roof, RCC shelves ramps etc complete all as specified and shown on drawings at Mankhurd, Mumbai
Construction of block of 11 Car garages for MCPO with RCC framed structure including foundations RCC roof, RCC shelves ramps etc complete all as specified and shown on drawings at Colaba, Mumbai
Construction of block of 16 Scooter garages for Sailors with RCC framed structure including foudations RCC roof, RCC shelves ramps etc complete all as specified and shown on drawings at Mankhurd, Mumbai
Construction of block of 13 Scooter garages for Sailors with RCC framed structure including foudations RCC roof, RCC shelves ramps etc complete all as specified and shown on drawings at Mankhurd, Mumbai
Construction of block of 4 Scooter garages for MCPO/SAILORS/JWO/Airmen with RCC framed structure including foundations, RCC roof, RCC shelves ramps etc complete all as specified and shown on drawings at Mankhurd/Santacruz, Mumbai
Construction of block of 5 Scooter garages for MCPO/Sailors with RCC framed structure including foundations RCC roof, RCC shelves ramps etc complete all as specified and shown on drawings at Colaba, Mumbai
Construction of block of 8 Scooter garages for MCPO/Sailors with RCC framed structure including foundations RCC roof, RCC shelves ramps etc complete all as specified and shown on drawings at Mankhurd, Mumbai
Construction of block of 12 Scooter garages for Sailors with RCC framed structure including foundations RCC roof, RCC shelves ramps etc complete all as specified and shown on drawings at Colaba, Mumbai
Construction of block of 12 Scooter garages for Sailors with RCC framed structure including foundations RCC roof, RCC shelves ramps etc complete all as specified and shown on drawings at Colaba, Mumbai
Construction of block of 10 Scooter garages for Sailors with RCC framed structure including foundations RCC roof, RCC shelves ramps etc complete all as specified and shown on drawings at Mankhurd, Mumbai
Completion of balance work for Construction of block of 4 Scooter garages for MCPO/SAILORS/JWO/Airmen with RCC framed structure including foundations, RCC roof, RCC shelves ramps etc complete all as specified and shown on drawings at Mankhurd/Santacruz, Mumbai
Construction of garbage bin with plinth protection complete all as specified and shown on drawings at Site (Colaba-2, Mankand-2,Kalina-1, Santacruz-2) Total-7
SCHEDULE "A", SECTION - II: LIST OF WORKS AND PRICES FOR INTERNAL WATER SUPPLY
SCHEDULE "A", SECTION - III: LIST OF WORKS AND PRICES FOR INTERNAL ELECTRIFICATION
SCHEDULE "A", SECTION - IV: LIST OF WORKS AND PRICES FOR ROAD, PATH AND CULVERT
SCHEDULE "A", SECTION - V: LIST OF WORKS AND PRICES FOR AREA DRAINAGE
SCHEDULE "A", SECTION - VI: LIST OF WORKS AND PRICES FOR FENCING, COMPOUND WALL AND GATES
SCHEDULE "A", SECTION - VII: LIST OF WORKS AND PRICES FOR STREET LIGHTING
M & L sand filling in & around the cable including in & around punning down for cushioning complete as directed by Project Manager.
Supplying & laying un reinforced precast concrete cable cover, class HVP Type I with peak size 300mm x 180mm x 40.mm
Supply, laying & jointing reinforcement concrete pipe 100 mm bore class NP-2 including collars as necessary for road crossing all as specified & directed (Earth work shall be measured & paid separately under respective item of schedule-A)
Suppy & laying in trenches/ pipe/ duct floor cable heavy duty armoured XLPE insulated & sheathed as per IS 1100 Volts grade Aluminium stranded conductor cable earth of size 6 sqmm 4 core all as specified & directed by Project Manager (Earth work sand cushioning & cable cover shall be measured & paid separately)
Suppy & laying in trenches/ pipe/ duct floor cable heavy duty armoured XLPE insulated & sheathed as per IS 1100 Volts grade Aluminium stranded conductor cable earth of size 25 sqmm 3.5 core all as specified & directed by Project Manager (Earth work sand cushioning & cable cover shall be measured & paid separately)
Supply & termination of 4Cx 6Sq mm aluminium armoured cable with suitable size single compression brass cable gland & copper lugs complete.
Supply & termination of 3.5Cx 25Sq mm aluminium armoured cable with suitable size single compression brass cable gland & copper lugs complete.
Supply & erecting of steel tubular swaged poles single bend to shape complete with cast iron base plates, bolts, nuts & screws as specified Type 410 SP-31 (9.00 Metre long) complete suitable for street light fittings with painting two coats of aluminium paint over a coat of red oxide zine chromate primer complete.
Supply & Laying of 2x2.5 Sq mm +1.5 Sq mm Multistrand copper conductor FRLS wire with 2 mm thick PVC sleeve of suitable size from street light pole marshalling box to light fixture complete with termination to MCB as directed by Project Manager
M & L for PCC 1:4:8 D-2 using stone aggregate of 40mm grade as in foundation concrete for pole including finishing the exposed surface using extra cement all as specified as per drawings & specification.
M & L for PCC 1:3:6 type C2 using stone aggregate of 20 mm grade as in foundation concrete for pole including finishing the exposed surface using extra cement all as specified as per drawings & specification.
Supply & errection of weather proof marshalling box with hinged door with proper size gasket etc. of size 300 x250 x135 mm for street light poles made of 14 SWG GI sheet with two coats of enamel paint red oxide primer alongwith 6 Amps SP MCB on din rail for phase & terminals blocks 3C x2.5 Sq mm cable glanding & proper fixing of clamp with bolts & nuts complete all as specified & directed by the Project Manager
Supply & fixing of street light luminaire HPSV 150 W single piece die cast/ Deep drawn aluminium housing complete with control gear compartment acrylic cover UV stabilised, blast of dual taping dynamic power saving device of reduce power & wattage to 100W after 6 hours of peak load pre-wired complete with lamp & including arrangement for mounting GI pipe suitable size bracket arm complete with connection etc as specified
Supply & laying earth continuity conductor for main earthing lead of size 8 SWG (4 mm dia) GI wire fixed to wall or chased buried in ground or fixed to poles or any other indicated situation for loop earthings as required.
Earthing complete with galvanised steel earth pipe electrode 40 mm bore medium grade 2.5m length buried directly & preferably vertically in ground with top edge not less than 1.25 metres below ground level connected with earthing lead of 4mm dia galvanised iron of steel wire all as shown in Plate no 4- SSR Part I to the earthing test point all as specified & indicated including earth pit & trench, excavation, removal of surplus soil, PCC pit cover with fitting hook, funnel with watering pipe with wire mesh, charcoal salt, testing.
Supply & fixing of sodium Vapour Lamp Type 70 W post top lantern type complete with control gear cover etc with lamp 70W HPSV, connection PVC cable 3 x2.5 sq.mm copper conductor with 3M long 50 mm dia GI pipe, PCC foundation complete all as specified & directed by the Project Manager.
Earthing complete with galvanised steel earth plate electrode 600 x600 x 6 mm thick buried directly in ground not less than 2.25 metres deep below ground level connected to galvanised iron strip 32 x6 mm as earthing lead by means of bolts, check nuts & washers of galvanised iron of steel wire all as shown in drg details, earth pit & trench connected to earthing test point all as specified & indicated with & including excavation & earth work in any type of soil & removal of surplus soil upto 50m, PCC pit cover with lifting hook, funnel with watering pipe with wire mesh, charcoal salt testing.
Supply & fixing of 1 x150 W HPMV street light fixture complete with control gear & lamp etc all as specified & directed by the Project Manager
Supply, installation & commissioning of feeder pillar for street lights, cubicle type weather proof double door & sloped canopy outdoor type, totally enclosed factory made, dust & vermin proof, fabricated from CRCA sheet minimum 2 mm thick including painting as per the 7 tank process suitable for 415 Volts, 3-Phase, 50 C/S AC supply & space for spare feeders as shown including the cost of RC pedestal (1:2:4) to be included in the rate offered for each item & comprising of the following INCOMING (I) MCB, 3-Phase, 4 Pole, 63 Amps 25 KA 415 Volts -1 No (ii) Busbars, 3-Phase, 4 Strips of Aluminium strips, 25KA rating, 100 Amps - 1 set OUTGOING a) 20 Amps TPN MCCB, 25 KA,415Volts, 3 Phase- 415 Volts 50 C/S AC supply - 2 Nos with Timer switch 415 Volts, 3 Phase-, 50 C/S AC Supply of 20 Amps rating with contractors 3 phase complete fittings & connection to LT cable for street light poles, use of timer controls with control to reduce the lighting as under:- (i) 6 PM to 10 PM : 100% (ii) 10 PM to 02 PM - 66% (iii) 2 PM to 6 PM-33%
M&L for rendering 10mm thick plaster on fair faces of brick work or concrete surface in CM 1:4 finished even & smooth without using extra cement.
Supply, fixing testing and commissioning of 12.5 meter of high mast soft in two sections suitable for 50M/ sec wind speed with raising and lowering system comprising of head frame luminaries carriage suitable to install 12 Nos luminaries in symmetrical arrangement double drum winch, six mm dia SS wire rope trailing cable, connector, integral power tool motor, manual handle, junction box, lighting finial complete all as specified and directed.
Supply of foundation bolts manufactured from special steel alongwith nuts, washers, anchor plates & templates suitable for item No 7.21 above
Supply & installation of Non integral flood light luminaries type BGEMF 22 R with 2 Nos 400 W SVT lamps & their control gear boxes.
Supply, installation & commissioning of outdoor stand mounted feeder pillar with 63A TPN MCB as incomer, single dial time switch of 45A Triple pole type contractor for Automatic switching of luminaries power tool control with 2 Nos 9 A contractor & raise lower push button incoming 35 Sqmm & outgoing 16 & 25 Sqm mm terminal.
Supply & fixing 40mm GI pipe light grade 1.2 M long partly in ground and partly alongwith the existing pole bending etc as required.
Numbering of all lighting poles with enamel paint
SCHEDULE "A", SECTION - VIII: LIST OF WORKS AND PRICES FOR LIGHTENING CONDUCTOR
SCHEDULE "A", SECTION - IX: LIST OF WORKS AND PRICES FOR FIRE FIGHTING
FOR NAVY AT COLABA SITE (S+10) 37 DU'S Electrical Motor Driven Fire Pump Set 1 for Hydrant System Supply, installation, testing and commissioning of TAC approved electric motor driven Main fire Pump set suitable for automatic operation consisting of the following & as per specifications. (a) Pump shall be of centrifugal multistage type, vertically split casing horizontal end suction, single stage with cast iron body, bronze impeller & wear ring, SS shaft & shaft sleeve directly driven by electrical motor as per N B C - 1983 for fire fighting suitable for deliver of 2280lpm developing not less than 10 kg/cm2 pressure alongwith pump cooling system. pump shall be capable of giving a discharge of not less than 150% of the rated discharge at a head not less than 65% or rated head & shut off head shall not exceed 120% rated head. (b) Squirrel cage, induction motor confirm to IS:325-1978 suitable for operation at 415 V +/- 15% 3 phase, 50 + 5% Hz AC supply totally enclosed, fan cooled type & conforming to protection clause IP 55 as per IS:4691 & insulation class shall be F with temp, rise limited to B rated for continuous duty and shall have HP rating to drive pump at 150% of its rated discharge or at 120% of rated head, whichever is more. (c) Common base plate fabricated out of MS channel, coupling guard plain cement of RCC pump foundation and vibration pads gland packing gland drain line & Min, follow line with isolation valve pressure guage with SS U-tube, Y-tube suction strainer, Pr switch for automatic pump operation. (d) Testing painting start-stop pressure setting shall be as per tender requirements, Pump-2280 lpm 90M Head Motor 60 Hp, 2900 RPM.
FOR NAVY AT COLABA SITE (S+14)=54 DUs Electrical Motor Driven Fire Pump set 1 for Hydrant System & 1 for Sprinkler System. Supply, installation, testing and commissioning of TAC approved Diesel Engine driven Fire Pump set suitable for automatic operation of the following & as per specifications. (a) Pump shall be of centrifugal multistage type, vertically split casing horizontal end suction, single stage with sleeve directly driven by Diesel engine as per NBC 1983 fire fighting suitable for delivery of 2280 lpm 115M Head developing not less than 10 kg/cm2 pressure Pump shall be capable of giving a discharge of not less than 150% of the rates discharge at a head net less than 65% of rated head & shut off head shall not exceeded 120% rated head. (b) Squirrel cage, induction motor confirm to IS:325-1978 suitable for operation at 415 V +/- 15% 3 phase, 50 + 5% Hz AC supply totally enclosed, fan cooled type & conforming to protection clause IP 55 as per IS:4691 & insulation class shall be F with temp, rise limited to B rated for continuous duty and shall have HP rating to drive pump at 150% of its rated discharge or at 120% of rated head, whichever is more. (c) Common base plate fabricated out of MS channel, coupling guard plain cement of RCC pump foundation and vibration pads gland packing gland drain line & Min, follow line with isolation valve pressure gauge with SS U-tube, Y-tube suction strainer, Pr switch for automatic pump operation. (d) Testing painting start-stop pressure setting shall be as per tender requirements, Pump-2280 lpm 100M Head Motor 65 Hp, 2900 RPM.
FOR NAVY AT MANKHURD SITE (S+16) =63 DUs Electrical Motor Driven Fire Pump set 1 for Hydrant System & 1 for Sprinkler System. Supply, installation, testing and commissioning of TAC approved electric motor driven Main fire Pump set suitable for automatic operation consisting of the following & as per specifications. (a) Pump shall be of centrifugal multistage type, vertically split casing horizontal end suction, single stage IP 55 enclosures with cast iron body, bronze impeller & wear ring, SS shaft & shaft sleeve directly driven by TEFC electrical motor as per N B C - 1983 for fire fighting suitable for delivery of 180 lpm 115M Head developing not less than 10 kg/cm2 pressure. (b) Squirrel cage, induction motor confirm to IS:325-1978 suitable for operation at 415 V +/- 15% 3 phase, 50 + 5% Hz AC supply totally enclosed, fan cooled type & conforming to protection clause IP 55 as per IS:4691 & insulation class shall be F with temp, rise limited to B rated for continuous duty and shall have HP rating to drive pump at 150% of its rated discharge or at 120% of rated head, whichever is more. (c) Common base plate fabricated out of MS channel, coupling guard plain cement of RCC pump foundation and vibration pads gland packing gland drain line & Min, follow line with isolation valve pressure gauge with SS U-tube, Y-tube suction strainer, Pr switch for automatic pump operation. (d) Testing painting start-stop pressure setting shall be as per tender requirements, Pump-2280 lpm 110M Head Motor 100 Hp, 2900 RPM.
Diesel engine driven pump SET FOR navy at Colaba site (s+10)=37 Supply, installation, testing and commissioning of TAC approved Diesel Engine driven Fire Pump set suitable for automatic operation of the following & as per specifications. (a) Pump shall be of centrifugal multistage type, vertically split casing horizontal end suction, single stage with sleeve directly driven by Diesel engine as per NBC 1983 fire fighting suitable for delivery of 2280 lpm 90 M Head developing not less than 10 kg/cm2 pressure Pump shall be capable of giving a discharge of not less than 10% of the rates discharge at a head net less than 65% of rated head & shut off head shall not exceeded 120% rated head. b) The engine shall be cold starting type, multi cylinder, vertical 4 stroke cycle, water cooled conforming to BS:649/I: 1601/ IS:10002 developing suitable HP to drive the fire pump. The engine shall be capable to drive the pump at 150% rated discharge or at 120% of its rated head whichever is more shall have 10% overload capacity of one hour in any period of 12 hours continuous run. c) Engine shall be complete with automatic starting mechanical with electrical batteries, flywheel cooling system fuel oil system, LO system fuel services tank, filters, exhaust silencer, instrument panel etc. d) common base plate fabricated out of MS channel, coupling guard plain cement of RCC pump foundation anti vibration pads gland packing gland drain line & Min, follow line with isolation valve pressure gauge with SS U-tube, Y-tube suction strainer, Pr switch for automatic pump operation. testing painting start-stop pressure setting be as per specifications.
Diesel engine driven pump Set for Navy at Colaba site (s+14)=54 DUs- Supply, installation, testing and commissioning of TAC approved Diesel Engine driven Fire Pump set suitable for automatic operation of the following & as per specifications. (a) Pump shall be of centrifugal multistage type, vertically split casing horizontal end suction, single stage with sleeve directly driven by Diesel engine as per NBC 1983 fire fighting suitable for delivery of 2280 lpm 90M Head developing not less than 10 kg/cm2 pressure Pump shall be capable of giving a discharge of not less than 10% of the rates discharge at a head net less than 65% of rated head & shut off head shall not exceeded 120% rated head. (b) The engine shall be cold starting type, multi cylinder, vertical 4 stroke cycle, water cooled conforming to BS:649/I: 1601/ IS:10002 developing suitable HP to drive the fire pump. The engine shall be capable to drive the pump at 150% rated discharge or at 120 of its rated head whichever is more shall have 10% overload capacity of one hour in any period of 12 hours continuous run. c) Engine shall be complete with automatic starting mechanical with electrical batteries, flywheel cooling system fuel oil system, LO system fuel services tank, filters, exhaust silencer, instrument panel etc. d) Common base plate fabricated out of MS channel, coupling guard plain cement of RCC pump foundation anti vibration pads gland packing gland drain line & Min, follow line with isolation valve pressure gauge with SS U-tube, Y-tube suction strainer, Pr switch for automatic pump operation. testing painting start-stop pressure setting be as per specifications.
Diesel engine driven for pump Set for Navy at Mankhurd (S+16) =63 DUs Supply, installation, testing and commissioning of TAC approved Diesel Engine driven Fire Pump set suitable for automatic operation of the following & as per specifications. (a) Pump shall be of centrifugal multistage type, vertically split casing horizontal end suction, single stage with sleeve directly driven by Diesel engine as per NBC 1983 fire fighting suitable for delivery of 2280 lpm 97M Head developing not less than 10 kg/cm2 pressure Pump shall be capable of giving a discharge of not less than 10% of the rates discharge at a head net less than 65% of rated head & shut off head shall not exceeded 120% rated head. (b) The engine shall be cold starting type, multi cylinder, vertical 4 stroke cycle, water cooled conforming to BS:649/I: 1601/ IS:10002 developing suitable HP to drive the fire pump. The engine shall be capable to drive the pump at 150% rated discharge or at 120 of its rated head whichever is more shall have 10% overload capacity of one hour in any period of 12 hours continuous run. c) Engine shall be complete with automatic starting mechanical with electrical batteries, flywheel cooling system fuel oil system, LO system fuel services tank, filters, exhaust silencer, instrument panel etc. d) Common base plate fabricated out of MS channel, coupling guard plain cement of RCC pump foundation anti vibration pads gland packing gland drain line & Min, follow line with isolation valve pressure gauge with SS U-tube, Y-tube suction strainer, Pr switch for automatic pump operation. testing painting start-stop pressure setting be as per specifications.
Jockey Pump set for Navy at Colaba site (S+10) =37 DUs Supply, installation, testing and commissioning of TAC approved electric motor driven Main fire Pump set suitable for automatic operation consisting of the following & as per specifications. (a) Pump shall be of centrifugal type, vertically split casing horizontal end suction, single stage IP 55 enclosures with cast iron body, bronze impeller & wear ring, SS shaft & shaft sleeve directly driven by TEFC electrical motor as per N B C - 1983 for fire fighting suitable for delivery of 180 lpm 70M Head developing not less than 10 kg/cm2 pressure. (b) Squirrel cage, induction motor confirm to IS:325-1978 suitable for operation at 415 V +/- 15% 3 phase, 50 + 5% Hz AC supply totally enclosed, fan cooled type & conforming to protection clause IP 55 as per IS:4691 & insulation class shall be F with temp, rise limited to B rated for continuous duty and shall have HP rating to drive pump at 150% of its rated discharge or at 120% of rated head, whichever is more. c) Common base plate fabricated out of MS channel, coupling guard plain cement concrete of RCC pump foundation anti vibration pads gland packing gland drain line & Min, follow line with isolation valve pressure gauge with SS U-tube, Y-tube suction strainer, Pr switch for automatic pump operation. testing painting start-stop pressure setting shall be as per tender requirements.
Jockey Pump set for Navy at Colaba site (S+14) =54 DUs Supply, installation, testing and commissioning of TAC approved electric motor driven Main fire Pump set suitable for automatic operation consisting of the following & as per specifications. (a) Pump shall be of centrifugal multistage type, vertically split casing horizontal end suction, single stage IP 55 enclosures with cast iron body, bronze impeller & wear ring, SS shaft & shaft sleeve directly driven by TEFC electrical motor as per N B C - 1983 for fire fighting suitable for delivery of 180 lpm 90M Head developing not less than 10 kg/cm2 pressure. (b) Squirrel cage, induction motor confirm to IS:325-1978 suitable for operation at 415 V +/- 15% 3 phase, 50 + 5% Hz AC supply totally enclosed, fan cooled type & conforming to protection clause IP 55 as per IS:4691 & insulation class shall be F with temp, rise limited to B rated for continuous duty and shall have HP rating to drive pump at 150% of its rated discharge or at 120% of rated head, whichever is more. c) Common base plate fabricated out of MS channel, coupling guard plain cement of RCC pump foundation anti vibration pads gland packing gland drain line & Min, follow line with isolation valve pressure gauge with SS U-tube, Y-tube suction strainer, Pr switch for automatic pump operation. testing painting start-stop pressure setting shall be as per tender requirements.
Jockey Pump set for Navy at Mankhurd (S+16) = 63 DUs Supply, installation, testing and commissioning of TAC approved electric motor driven Main fire Pump set suitable for automatic operation consisting of the following & as per specifications. (a) Pump shall be of centrifugal multistage type, vertically split casing horizontal end suction, single stage IP 55 enclosures with cast iron body, bronze impeller & wear ring, SS shaft & shaft sleeve directly driven by TEFC electrical motor as per N B C - 1983 for fire fighting suitable for delivery of 180 lpm 97M Head developing not less than 10 kg/cm2 pressure. (b) Squirrel cage, induction motor confirm to IS:325-1978 suitable for operation at 415 V +/- 15% 3 phase, 50 + 5% Hz AC supply totally enclosed, fan cooled type & conforming to protection clause IP 55 as per IS:4691 & insulation class shall be F with temp, rise limited to B rated for continuous duty and shall have HP rating to drive pump at 150% of its rated discharge or at 120% of rated head, whichever is more. c) Common base plate fabricated out of MS channel, coupling guard plain cement of RCC pump foundation anti vibration pads gland packing gland drain line & Min, follow line with isolation valve pressure gauge with SS U-tube, Y-tube suction strainer, Pr switch for automatic pump operation. testing painting start-stop pressure setting shall be as per tender requirements.
Supply, installation testing and commissioning of cubical type control panel board fabricated from 2 mm thick MS sheet and angle iron frame work, spray painted for main fire pumps, jockey pump & Diesel Engine Driven pump. The panel shall be dust and vermin proof totally enclosed free standing floor mounting type suitable for 415V 50 Hz 3 pahase 4 wire system complete in all respect and confirming to latest relevant of ISI specification including necessary connections, inter connection with copper conductor cable of required size, cable tray of required size, soldering etc. cubicle construction shall be conforming to IP 52 as per IS : 2147 with suitable size MCCB /NCB Incoming /out going completed all as specified & directed by PM.
Supply and install terrace Booster Pump 450 LPM, Head -35 Meter 7.5 HP (3PH-AC)
Supply and install terrace Booster Pump 900 LPM, Head -35 Meter 15 HP (3PH-AC)
Supply, installation & testing of MS/E RW heaving duty pipe (IS-1239 Part-I) 3589 Part-I 1974 heavy duty including cutting threading welding etc bend, elbows reducers unions, flanges, GI nuts bolts washer, etc including all welding / fixing and excavation refilling wherever required fixing the pipe in trench complete including anti-corrosive treatment with one coat of hot coal and two wraps of reinforced, fibre glass tissue as per IS-10221 : 1982, hydrortate testing etc for the following sizes complete all as specified, as shown on drawing and as directed by PM: -
a) 200 mm dia
b) 150 mm dia
c) 100 mm dia
d) 80 mm dia
Supply, fixing, welding, testing and commissioning of ERW pipe (heavy duty) conforming to IS-1239 with required accessories and pipe fittings like flange, tee elbow, bend nipple, coupling, cap, reducer, union, flange joint, CAF insertion, nut bolt eye and rediography limited to 10 including fixing the pipe with suitable GI flat strip clamp / U clamp/brackets/hanger and painting with one coast of primer and two or more coats of post office red enamel paint of approved brand, hydrostatic testing etc. for the following sizes complete all as specified, as shown on drawing and as directed by PM: -
a) 200 mm dia pipe
b) 150 mm dia pipe
c) 100 mm dia pipe
d) 80 mm dia pipe
e) 65 mm dia pipe
f) 50 mm dia pipe
g) 40 mm dia pipe
h) 32 mm dia pipe
j) 25 mm dia pipe
Supply, fixing CI double flanged valves with companion flanges, non return valve including nut and bolt 1.5mm thick compression gasket with accompanying flanges for the following sizes complete all as specified, as shown on drawing and as directed by PM: -.
a) 150 mm dia
b) 100 mmdia
c) 80 mm dia
d) 65 mmdia
Supplying, fixing testing and commissioning of ISI marked cast iron double flanged Butter Fly valve complete with companion flanges, pipe fittings, bolts nuts CAF gasket etc duly painted for the following sizes complete all as specified, as shown on drawing and as directed by PM: -.
a) 200 mm dia
b)150 mm dia
c) 100 mm dia
d) 80 mm dia
e) 65 mm dia
f) 50 mm dia
Supply, fixing, testing and commissioning of Air release valve brass body 32mm (gate valve) dia in riser with isolating valve.
Supply and fixing bolting, welding. Radiography testing painting and commissioning of hydrant valves single headed ISI marked 63 mm dia single headed landing valve CI hand wheel CAF gasket nuts, bols, etc conforming to IS:5290-1977 type A for internal hydrants as per specifications and instructions of site incharge.
Supply and fixing ISI marked 63mm dia male instantaneous inlet spray nozzle made of gun metal to IS:903 arrangment for straight stream spray, shut-off and trigger type handle as per specifications.
Supply and fixing fire fighting delivery hose, PRL Hose pipe 15M long 63 mm dia ISI marked, non-percolating, flexible, 3 layered synthetic jacketed with electrometric outer covering resistant to liquids, chemicals, acids, alkalis, solvents, abrasion & heat having 42 kg/ cm2 burst pressure 18 kg /cm2 working pressure conforming to IS:636-1988 type -B and having TAC MMD approvals in 15 mtr length with copper wire bounded. instantaneous type 63 mm fire hose pair of male & female couping made of aluminium alloy (anodised) in each run of hose conforming to IS:903 as per specifciations.
Supply and fixing ISI marked first aid fire hose reel conforming to IS:884-1985 comprise of reel hose guide, full swing drum fixing bracket, 20 mm bore 36 meters long high-pressurebraided rubber hose tubing confom to IS:1532-1969,25 mm dia ball valve, stainless steel stop cock and nozzle duly painted as per tender requirements / specifications and instructions of site incharge.
Supply, installation & testing of MS fire hose cabinet fabricated from 16 gauge MS sheet of fully welded construction with hinged double front door with locking arrangement, full glass door 4 mm thick approved by local fire authority, painted with one coat of primer, stove enamelled fire red finshed FIRE HOSE written on front suitable to accomodate 1 hydrant landing, 1 fire hose red, 2 Nos 15 M long 63 mm dia hose, 1 branch pipe,1 fire main Axe, including suitably mounted on a raised masonary plat form as required.
Supply, Testing and commissioning pressure guage (2 Nos), pressure switch (1 Nos), valves pipes and fittings etc.
M&L Earthing with GI earth plate 600 mm x 600mm x 6mm thick including accessories and providing mansonry encloure with cover plate having locking arrangement and watering pipe etc with charcoal or coke and salt including providing and fixing 32 mm x 6 GI strip on surface or in recess for connection etc. as required and providing and fixing 4.00mm GI wire on surface or in recess for loop earthing as required and complete with excavation earthing pit with CI cover all as specified and as per SSR-II item no 3497.
Supply and installation weather proof hose cabinet of size 800 mm w x 1000 mm H, x 400 mm D for external yard hydrant fabricated out of 3mm thick MS sheet with 4 mm thick glazed glass door infront, having locking arrangement suitable to accommodate external yard hydrant with valve hose branch pipe with all necessary pipe accessories fittings etc mounted on wall as raised brick plat form and duly painted with post office red externally and white internally with synthatic enamel paint sign writing etc as required as specified.
Supply and fixing four way fire brigade inlet with 150 NB with Butter fly valve with matching flanges and with glass front floor with 1 No Butter fly valve and 1 No non return valve complete all as specified.
Supply and fixing Two No's of 63 mm dia instantaneous inlet arrangement on 150mm dia leader, 2 Nos, 150 mm slucie valve-1 No, 150 mm non -return valve, fabricated out of SWG MS sheet with central opening with red enamel painting complete.
Supplying & fixing self prming PVC tank of 700 litres capacity including pipe 25 mm dia GI for connection.
Supply & fixing GI puddle flanges, site fabricated from class C pipes - of 1 mtr length complete all as specified and directed forfolloing sizes:-
a) 150 mm dia
b) 100 mm dia
Coating and wrapping of underground pipes ISI Mark IWL make
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in deph for foundation etc. or for shafts, wells, cesspits, manholes, per holes etc. not exceeding 10 sq.m on plan and not exceeding 1.5m in depth and getting out as in soft/ loose soil complete all as specified.
Returning, filling, including spreading, levelling watering and well ramming in layers not exceeding 25cm
Removing excavated materials exc. 1.5m but not exceeding 5 Km and depositing where directed.
Supply and fixing suction coupling for the fire brigade for drawal of water from tank with 100 mm Dia pipe and foot valve (pipe 8M long) complete all as specified.
Supply and fixing suction coupling for the fire brigade fo drawal of water from tank with 150 mm dia pipe for foot valve (pipe 8 M long) complete all as specified.
Supply and fixing suction coupling for the fire brigade fo drawal of water from tank with 80 mm dia pipe for foot valve (pipe 8 M long) complete all as specified.
Supply and fixing 150 mm dia x 1.0 M high air vessel fabricated out of 8 mm thick MS sheet complete with dished top and bottom end. Air release valve tripod type stand, pressure gauge with ball valve, drain ball valve of 50mm dia with 2 or - lor g GI(H) piping complete as required.
Supply and fixing Aire Vessel on Top of wet riser with 450 mm dia 1.5mm high fabricted with 8mm thick mild steel sheet vent drain ball value (25mm NB) with all necessary accessories.
Supplying, installing testing & commissioning of conventional sprinkler quartzoid buld type with 15mm screwed and connection of 68 deg.c.temp, rating K 80 & orifice shall be not be less than 6 mm sprinkler shall be UL listed & FM approved with chrome finsihed.
Supply installing testing and commissioning of flow switch on sprinkler distribution on each floor and shall be connected to fire alarm panel through cable. a) Dia 32 mm
Supply installing testing and commissioning of flow switch on sprinkler distribution on each floor and shall be connected to fire alarm panel through cable.
Supply installing testing and commissioning of flow switch on aprinkler distribution on each floor and shall be connected to fire alarm panel through cable. a) Dia 80 mm
Supply installing testing and commissioning of gun metal chrome finished ball vbalve with fittings of scrwed end type 32 mm dia
Provision and constructing a masonry pit of internal dimension 1.0 x 1.0m x 1.0M depth of accommodate each of valves placed externally, wall to be of brick masonary in cement mortar 1:5 (1 cement : 5 fine sand) with SFRC medium duty 10 MT grade designation manhole cover with frame (560 mm internal dia conforming to IS:12592). The top slab RCC shall be 150 mm thick of 1:2:4 mix (! cement : 2 coarse sand : 4 graded same aggregate 20mm nominal size) and inside plastering with cement mortar 1:3 (! cement : 3 coarse sand) 12 mm thick, the man hole chamber shall be internally finished with commerical grade white glazed titles 6 mm thick complete as specified and directed by PM .
Supply and fixing CI body foot valve to be provided on suction line for each pumping sets of sizes as under:-
a) 150 mm dia
b) 80 mm dia
Supply and fixing "Y" stainer of CI body foot valve to be provided for suction line for each pumping sets of sizes as under:-
a) 150 mm dia
b) 80 mm dia
Fire Extinguisher Note: Rate shall be inclusive of clamps, hangers, installation and first charge etc.
Supply and fiixing of DCP powder type (ABC) 5 kgs capacity - ISI mark first (IS:2171/13849, 14609)
Supply and fixing of Fire Extingusher Mechancial foam (AFFF) Type 9 liters capacity (IS:10204)
Supply and fixing fire Extinguisher CO2 Type 5 kg Capacity (IS-2878)
FIRE ALARM SYSTEM Supplying, installing, testing and commissioning of Main Panel of 14 Zones for fire alarm system with suitable sounder cards and fault isolaters mounted at Security Room having facility of fire indicaions. The panel wall mounted cabinet shall be made out of 16 SWG CRCA sheets as per IS 2189. The main control panel should have provision of battery , have the arrangement for Audio/ Visual indications by dual lamps for fire and faults in each . Finished in stove have sealed NIckle Cadmium maintenanve free bettary housed in a wooden/ plastic box suporting stand and boost / trckle charger, DC voltmeter, short circuit fire alarm, pus button for lamp test, fire alarm circuits healthy checks etc complete all as specified and directed by PM.
Supplying, installing, testing and commissioning of Main Panel of 17 Zones for fire alarm system with suitable sounder cards and fault isolaters mounted at Security Room having facility of fire indicaions. The panel wall mounted cabinet shall be made out of 16 SWG CRCA sheets as per IS 2189. The main control panel should have provision of battery , have the arrangement for Audio/ Visual indications by dual lamps for fire and faults in each . Finished in stove have sealed NIckle Cadmium maintenanve free bettary housed in a wooden/ plastic box suporting stand and boost / trckle charger, DC voltmeter, short circuit fire alarm, pus button for lamp test, fire alarm circuits healthy checks etc complete all as specified and directed by PM.
Supplying, installing, testing and commissioning of Main Panel of 06 Zones for fire alarm system with suitable sounder cards and fault isolaters mounted at Security Room having facility of fire indicaions. The panel wall mounted cabinet shall be made out of 16 SWG CRCA sheets as per IS 2189. The main control panel should have provision of battery , have the arrangement for Audio/ Visual indications by dual lamps for fire and faults in each . Finished in stove have sealed NIckle Cadmium maintenanve free bettary housed in a wooden/ plastic box suporting stand and boost / trckle charger, DC voltmeter, short circuit fire alarm, pus button for lamp test, fire alarm circuits healthy checks etc complete all as specified and directed by PM.
Supplying, installing, testing and commissioning of dual tone elctronic hooter housed in 16 SWG sheet steel enclosure finished in stove enamel PO red paint suitable for wall/ ceiling mounted complete including connections etc as per tender requirements / specifications.
Supplying, installing, testing and commissioning of manual call point cmpletly recessed (break glass unit) housed in existing 16 SWG sheet steel housing including Siemens / L&T push button switch(spring cing loaded action) with Normally closed / Normally open contracts as per specifications.
Supply and drawing of 2.5 sq mm single core FRLS standard PVC insulated copper conductor cable confirming to IS 694 (Part I) in rigid steel conduit in recess / surface including terminations and connections etc as required(rates for rigid steel conduit are also included in rates quoted by contractor).
Supply , fixing testing and commissioning of Zonal panel to be installed at stilt area , except battery and battery charging system.
FOR NAVY AT Mankhurd SITE (S+12)=46 DUs Electrical Motor Driven Fire Pump set 1 for Hydrant System & 1 for Sprinkler System. Supply, installation, testing and commissioning of TAC approved Diesel Engine driven Fire Pump set suitable for automatic operation of the following & as per specifications. (a) Pump shall be of centrifugal multistage type, vertically split casing horizontal end suction, single stage with sleeve directly driven by Diesel engine as per NBC 1983 firefighting suitable for delivery of 2280 lpm 115M Head developing not less than 10 kg/cm2 pressure Pump shall be capable of giving a discharge of not less than 150% of the rates discharge at a head net less than 65% of rated head & shut off head shall not exceeded 120% rated head. (b) Squirrel cage, induction motor confirm to IS:325-1978 suitable for operation at 415 V +/- 15% 3 phase, 50 + 5% Hz AC supply totally enclosed, fan cooled type & conforming to protection clause IP 55 as per IS:4691 & insulation class shall be F with temp, rise limited to B rated for continuous duty and shall have HP rating to drive pump at 150% of its rated discharge or at 120% of rated head, whichever is more. (c) Common base plate fabricated out of MS channel, coupling guard plain cement of RCC pump foundation and vibration pads gland packing gland drain line & Min, follow line with isolation valve pressure gauge with SS U-tube, Y-tube suction strainer, Pr switch for automatic pump operation. (d) Testing painting start-stop pressure setting shall be as per tender requirements, Pump-2280 lpm 100M Head Motor 65 Hp, 2900 RPM.
Diesel engine driven pump Set for FOR NAVY AT Mankhurd SITE (S+12)=46 DUs Supply, installation, testing and commissioning of TAC approved Diesel Engine driven Fire Pump set suitable for automatic operation of the following & as per specifications. (a) Pump shall be of centrifugal multistage type, vertically split casing horizontal end suction, single stage with sleeve directly driven by Diesel engine as per NBC 1983 firefighting suitable for delivery of 2280 lpm 90M Head developing not less than 10 kg/cm2 pressure Pump shall be capable of giving a discharge of not less than 10% of the rates discharge at a head net less than 65% of rated head & shut off head shall not exceeded 120% rated head. (b) The engine shall be cold starting type, multi cylinder, vertical 4 stroke cycle, water cooled conforming to BS:649/I: 1601/ IS:10002 developing suitable HP to drive the fire pump. The engine shall be capable to drive the pump at 150% rated discharge or at 120 of its rated head whichever is more shall have 10% overload capacity of one hour in any period of 12 hours continuous run. c) Engine shall be complete with automatic starting mechanical with electrical batteries, flywheel cooling system fuel oil system, LO system fuel services tank, filters, exhaust silencer, instrument panel etc. d) common base plate fabricated out of MS channel, coupling guard plain cement of RCC pump foundation anti vibration pads gland packing gland drain line & Min, follow line with isolation valve pressure gauge with SS U-tube, Y-tube suction strainer, Pr switch for automatic pump operation. testing painting start-stop pressure setting be as per specifications.
Jockey Pump set for Navy at Mankhurd site (S+12) =46 DUs Supply, installation, testing and commissioning of TAC approved electric motor driven Main fire Pump set suitable for automatic operation consisting of the following & as per specifications. (a) Pump shall be of centrifugal multistage type, vertically split casing horizontal end suction, single stage IP 55 enclosures with cast iron body, bronze impeller & wear ring, SS shaft & shaft sleeve directly driven by TEFC electrical motor as per N B C - 1983 for firefighting suitable for delivery of 180 lpm 90M Head developing not less than 10 kg/cm2 pressure. (b) Squirrel cage, induction motor confirm to IS:325-1978 suitable for operation at 415 V +/- 15% 3 phase, 50 + 5% Hz AC supply totally enclosed, fan cooled type & conforming to protection clause IP 55 as per IS:4691 & insulation class shall be F with temp, rise limited to B rated for continuous duty and shall have HP rating to drive pump at 150% of its rated discharge or at 120% of rated head, whichever is more. c) Common base plate fabricated out of MS channel, coupling guard plain cement of RCC pump foundation anti vibration pads gland packing gland drain line & Min, follow line with isolation valve pressure gauge with SS U-tube, Y-tube suction strainer, PR switch for automatic pump operation. testing painting start-stop pressure setting shall be as per tender requirements.
SCHEDULE "A", SECTION - X: LIST OF WORKS AND PRICES FOR LIFT
Supply and laying cable XLPE insulated electric power cable armoured (heavy Duty) 1100 Volts as per IS1554 (Part-I) standed Aluminium conductor 25 sqmm 3.5 case complete all as specified and directed by PM
Supply and laying cable XLPE insulated electric power cable armoured (heavy Duty) 1100 Volts as per IS1554 (Part-I) standed Aluminium conductor 50 sqmm 3.5 case complete all as specified and directed by PM
Supply & termination of 4C x6 sqmm Aluminium armoured cable with suitable size single compression brass cable gland & copper lugs complete.
Supply & termination of 3.5C x 25 sqmm Aluminium armoured cable with suitable size single compression brass cable gland & copper lugs complete.
SCHEDULE "A", SECTION - XI: LIST OF WORKS AND PRICES FOR AVIATION LIGHTS
Supply, fixing, testing and commissioning of aviation heavy duty & weather proof obstruction light long life noon cold cathode hellix lamp lighting fixtures Bajaj cat No BJAOL1 or equivalent including non lamp in 75VA step up transformer, heat resistant clear thick glass and accessries. Fixture shall have die cast aluminium alloy housing including connection complete with red clear lamp,control switch etc all as specified as directed by PM
Supply and lying 3 core copper conductor heavy duty PVC insulated 1.1KV 2.5sqm armoured cable for aviation light including time switch with conducter in steel enclosures
Termination of 3 core 2.5 sq mm cable using suitable size single compression type cable gland and dowels make lugs complete with making proper connections including time switch 20A rating with conducter and steel
SCHEDULE "A", SECTION - XII: LIST OF WORKS AND PRICES FOR CRADDLE SYSTEM
Design, supply, installaions, testing and commissioing (portable type) cradle system (façade access system) of approved make for façade access or cleaning complete as per manufacturer's specification and including the following i.e (a) to (g). (a) Two man slewing power craddle of 180 kg capacity and able to turn 90 degrees, with fully welded connections, with inner and outer frame, central control facility, aluminium chequerred flooring, fully covered foam buffering, traction hoist with lever, brakes, castor wheels, locking arrangement, 2 pairs of 8mm dia GI wires power reelers etc - 1 Nos . (b) Top slwing 360 degrees rotating type Aluminium alloy davits with mill finish and sealed fabricated mild steel hot dip galvanised base as shown in drawings, including components such as mast, pivoting booms, boom brake assembly, traversing trolley with break, transport wheels extra 04 Nos. (c) Sockets for davits comprising of hot dip galvanised plates and hot dip galvanised finish, with fixing arrangement at terrace at required level, floor type or roof type mouting, and accessories such as stainless steel pins for holding in position etc complete as shown and spcified - 90 Nos. (d) Holding down units - 180 sets for each building. (e) Aluminium alloy jibs - 2 Nos for each building. (f) Anchorage for above - 12 Nos for each building. (g) Holding down units - 2 Nos for each building. Note :- The details of foundation and mounting system of required size and shape at terrace level at required locations and levels shall beprovided by project manager as per the spcification requirement of manufacturers and are to be provided on roof of each multistoried residentional block as spcified in schedulde The cost of this shall deemed to be included in the cost of above cradle items (site Colaba Mumbai )
SCHEDULE "A" SECTION - XIV: LIST OF WORKS AND PRICES FOR SITE CLEARANCE AND AREA DEVELOPMENT
SCHEDULE "A" SECTION - XV (XVA1, XVA2, XVB) : LIST OF WORKS AND PRICES FOR SCHEDULE OF CREDIT
SCHEDULE "A" SECTION - XVI: LIST OF WORKS AND PRICES FOR SCHEDULE OF CREDIT (DEMOLITION) Note for item No 14 & 15 above:- Rate/ amount as fixed by the department and as quoted by the tenderer, whichever is more shall be taken for calculating the amount to arrive at the total amount of schedule of credit for acceptance purpose.
Som Projects Pvt. Ltd. (BID ID -3231106)
Inderjit Mehta Constructions Pvt Ltd (BID ID -3230496)
Generic Engineering Construction and Projects Ltd (BID ID -3226892)
GIRDHARI LAL CONSTRUCTIONS PVT LTD (BID ID -3229046)
Skyway Infraprojects Pvt Ltd (BID ID -3234855)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.08 MB
Download all tender documents and submit your bid