Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹44.9 LAccepted-AOC | L1 | Accepted-AOC ACCEPTED | |
| 2 | L2₹46.0 L+₹1.1 L (2.42%)Rejected-AOC | L2 | Rejected-AOC REJECTED | |
| 3 | L3₹47.4 L+₹2.5 L (5.54%)Rejected-AOC | L3 | Rejected-AOC REJECTED | |
| 4 | L4₹49.6 L+₹4.7 L (10.4%)Rejected-AOC | L4 | Rejected-AOC REJECTED |
Tender Value
Refer Docs
EMD Value
₹90,000
Closing Date
22 Oct 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE(NW)BHNADUP
GE(NW)BHNADUP,MUMBAI
REPAIR/ REPLACEMENT TO WPT ,PLASTERING ,REPAIR TO STRUCTURAL MEMBARS AND OTHER CONNECTED ITEMS OF CERTAIN BUILDINGS AT NCHC POWAI
2020_MES_380950_1
8869/B
Open Tender
Civil Works
Item Rate
274 days
POWAI
AS PER TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
GE(NW)BHNADUP
₹90,000
27 Jan 2021
25 Sept 2020
23 Oct 2020
25 Sept 2020
22 Oct 2020
7 Oct 2020
26 Sept 2020 - 30 Sept 2020
60 days
Amount
Taking down cement or cement lime mortar plaster, any description on brick or stone walls etc, including rackingout joints, hacking for key, scrubbing down with water etc complete as specified.
M&L for rendering 15 mm thick in CM 1:6 on brick walls finishing even and smooth without using extra cement etc complete all as specified and directed by EIC.
M/L for rendering 5 mm thick in CM 1:3 as in ceiling finished even and smooth without using extra cement etc complete all as specified and directed.
M&L for cement plaster 15 mm thick on walls in CM 1:4 finished even and smooth incl using water proofing compound @ 2% by weight of cement complete all as specified and directed (WPC shall be measured and paid separately).
Supply only integral water proofing compound.
M & L for preparation of new plastered surfaces of wall by brooming down smoke soot moulds moss and efflorecent salts and treating oil and greassy spots and thereafter applying two coat of white wash complete all as specified and directed
M & L for preparation of new plastered surfaces of wall and applying applying one coat of Primeseal primer of M/s Dr Fixit or equivalent chemical of M/s STP Ltd as approved by the GE or one coat of Chemstic PDE 600 elastomeric coating (and allowing to dry for 8hrs) under torch dry condition and subsequently applying two coats of water proofing decorative elastomeric coating system Raincoat of M/s Dr Fixit with DFT 100microns or Shalicryl 215 of M/s STP Ltd or Chemstic PDE 600 elastomeric coating (the surfaces after painting one coat shall be allowed to dry for 6 to 8hours before application of next coat) including necessary scaffolding etc complete all as per manufacturer instructions and all as specified & directed. Note: The aforesaid treatment shall be got executed by the contractor from the authorised applicator of the manufacturer(s) and also necessary authenticated documents on account of above shall be submitted by the contractor to the GE.
M&L for preparing the plastered surfaces of existing exterior walls, parapet walls, chajjas, etc. with wire brush to remove all loose dirt, oil grease, etc. and applying one coat of Primeseal primer of M/s Dr Fixit or equivalent chemical of M/s STP Ltd as approved by the GE or one coat of Chemstic PDE 600 elastomeric coating (and allowing to dry for 8hrs) under torch dry condition and subsequently applying two coats of water proofing decorative elastomeric coating system Raincoat of M/s Dr Fixit with DFT 100microns or Shalicryl 215 of M/s STP Ltd or Chemstic PDE 600 elastomeric coating (the surfaces after painting one coat shall be allowed to dry for 6 to 8hours before application of next coat) including necessary scaffolding etc complete all as per manufacturer instructions and all as specified & directed. Note: The aforesaid treatment shall be got executed by the contractor from the authorised applicator of the manufacturer(s) and also necessary authenticated documents on account of above shall be submitted by the contractor to the GE.
M&L for preparation of new plastered surface of celling and applying 2 coats of white wash complete all as specified and directed.
S & F PVC RWP ISI marked 110 mm bore with single sockted, in any length, fixed to walls with rubber ring joints, fixed in repairs complete all as specified and directed.
S & F PVC shoe 110 mm dia fixed to wall complete as specified.
S & F PVC bend 110 mm dia fixed to wall complete as specified.
S & F PVC RWP ISI marked 160 mm bore with single sockted, in any length, fixed to walls with rubber ring joints, fixed in repairs complete all as specified and directed.
S & F PVC shoe 160 mm dia fixed to wall complete as specified.
S & F PVC bend 160 mm dia fixed to wall complete as specified.
Taking down CI soil/waste and vent pipes of any length any size including fittings including cutting of holes wherever required.
S & F 110 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified & directed.
S & F 110 mm bore PVC (SWR) bends of any radius complete all as specified & directed.
S & F 110 mm bore PVC (SWR) branch piece single (Single `Y') equal or unequal with access door complete all as specified & directed.
S & F 110 mm bore PVC (SWR) branch piece double (Double `Y') equal or unequal with access door complete all as specified & directed.
S & F 110 mm bore PVC (SWR) Vent cowl complete all as specified & directed
S & F 75 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified & directed.
S & F 75 mm bore PVC (SWR) bends of any radius complete all as specified & directed.
S & F 75 mm bore PVC (SWR) branch piece single (Single `Y') equal or unequal with access door complete all as specified & directed.
S & F 75 mm bore PVC (SWR) branch piece double (Double `Y') equal or unequal with access door complete all as specified & directed.
S & F 75 mm bore PVC (SWR) Vent Cowl complete all as specified & directed
Taking up or down 25 mm bore GI tubing and connections with all fittings fixed to walls /ceiling/laid in floor etc complete all as specified and directed.
Suppling and laying of CPVC pipes SDR 11 of size 25mm & Plain CPVC SDR 11 Fitting on walls/ ceiling or laying in floors complete all as specified.
S&F in repairs 25mm Gun-metal, globe or gate valves with iron wheel head, screwed both ends for iron pipe and fixedcomplete all as specified and directed.
S&F in repairs 15mm bore stop valve/angle cock cast copper alloy ,chromium plated screwed down, high pressure with or without lettered hot or cold with long pipe complete all as specified and directed.
S/F in repairs PVC flushing cistern 10 ltrs capacity high level with inlet, ball valve, float and handle including brackets.
S&F in repairs PTMT Bibtaps standard any colour screwed down for iron pipe and fixed ( minimum weight 90 gm )complete all as specified and directed.
S & F vitreous china squatting pan Orissa pattern WC of size 580mm x 440 mm, white, of standard quality with integral foot rest including trap complete including connecting to trap and flushing pipe, anti syphonage pipe and soil waste pipe etc including lime concrete filling complete all as specified and directed.
M&L for special treatment for sunken portion of WCs/ Bath & toilet executed in following stages:- Stage 1 :- Demolition of WC including lime concrete and cement concrete coba etc and preparing the surfaces of existing sunken portion of WCs or bath etc with wire brush to remove all loose dirt, oil grease etc including removing debris outside MD land etc . Stage 2:- Providing 10mm thick plaster in CM 1:3 mixed with integral water proofing chemical of Dr. Fixit Pidicrete URP or plaster seal of STP Ltd in the proportion/quantity all as per Manufacture's instructions.Complete. Stage 3:- Apply Dr Fixit Primeseal primer or Equivalent of STP Ltd (and allow to dry for 8 hours) all as per Manufacture's instructions. Stage 4:- Apply two coats of water proofing elastomeric coating system of Dr Fixit Raincoats with DFT 100 Micron or shalicry 215 of STP (The surface after painting one coats shall be allowed to dry of 6 hours before next coats) all as per Manufacturer's instructions. Stage 5:- Rendering 10mm thick in CM 1:3 mixed with Integral water proofing chemical Dr Fixit Pidicrete URP or plaster seal of STP Ltd all as per Manufacture's instructions. Stage 6. All CI joints shall filled with mixture of cement fine sand and plaster seal of STP Ltd or Dr Fixit pidicrete URP all as per Manufacture's instruction. Stage 7:- Making holes in wall and fixing 600mm long 40mm dia medium grade GI spout for draining the surplus water if any . Stage 8:- Carry out ponding test for 48 hours to ensure water tightness of repaired sunken portion water tightness of repaired sunken portion and filling of sunken portion for cement concrete Type E2 1:5:10 using 40 mm graded aggregate as in lean concrete complete all as specified and directed. Note :- (a) Only plan area shall be measured and accorded for payment under this item. (b) Depth of sunken portion of WC's/Baths shall be upto 35cm, which is to be taken into account while quoting the rate against this item. (c) Rate quoted by Contractor shall be deemed to be included for all the horizontal and verticale treated surfaces of sunken portions of WC & Bath.
M & L Non skid ceramic tiles (Coloured) 7 to 8 mm thick of each tiles (Square / rectangular) exc 0.06 sqm but n exc 0.11sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15 mm thick screed bed in CM 1:6 laying floor finished complete all as specified and directed, Non skid ceramic tiles conforming to IS 13755 of grade B11 (a) complete all as specified and directed.
S & F in repairs PVC (SWR) floor trap with grating including jointing to waste pipe of 100mm bore in cement concrete type B1 (1:2:4) fixed in repairs complete all as specified and directed.
S&F in repair stainless steel grating in ground shape 100mm dia complete all as specified and directed.
Demolition of brick coba/cement concrete (unreinforced) from existing roof/terrace etc and also removing/taking down of existing water proofing treatment of any thickness in any position including cleaning the surfaces of roof etc with wire brush complete and removing the retreived debris out side MD land, all as specified and directed.
M&L for PCC (1:2:4) type B-0, using 12.5mm graded stone aggregate as in levelling course over RCC roof surface to achieve required slope including making rounded or chamfered on edges mixed with WPC @2% by weight of cement, complete all as specified and directed. Note : WPC shall be measured and paid separately as supply only.
M & L for APP modified roof treatment over existing roof slab etc to be executed through approved authorised applicator of the membrane manufacturer with the following specifications complete all as specified and directed:- (a) Applying oil bound bitumen primer @ 0.40 litre/ Sqm manufactured by the same manufacturer as that of APP with a density 0.87-0.89 Kg per litre at 25 degree centigrade on the prepared dry surface. (b) Laying APP modified water proofing membrane reinforced with non woven polyester fibre weight not less than 160gm/Sqcm using butane torch by torch application with 10cm side lap and 15cm end lap. (c) Physical properties of membrane shall be as under:- (i) Membrane weight not less than 3.50 Kg/Sqm. (ii) Non woven polyester weight not less than 160gm /sqm. (iii) Softening point of membrane not less than 150 degree Celsius. (iv) Joint tensile strength-longitudinal not less than 650N/Sqcm and transverse not less than 450 N/Sqcm. (v) Tear strength-longitudinal not less than 300 N & transverse not less than 250 N. (vi) Elongation : > 20% in both directions. (vii) Impermeability/water tightness at 2 Kgf/cm2. (viii) Water absorption - Not more than 1% on mass within 24 hours. (ix) Cold flexibility - Minimum (-) 20C. (x) Dimentional stability % change = Maximum 1%.
Hydraulically machine pressed cement concrete tiles of size 300x300X20mm thick (with grey cement and no pigment), set in neat cement slurry laid over terrace and roofs etc including provision of 15mm thick cement screed bedding layer in CM 1:4 mixed with integral water proofing compound, tiles joints shall be grouted and immediately after grouting, the joints shall be pointed flush in CM 1:3 (in separate process) mixed with integral water proofing compound etc, complete all as specified and directed. (Note : Integral water proofing compound will be measured and paid separately as supply only).
M&L for applying one coat of solar reflective bituminous aluminium paint @ 0.10 Kg/Sqm over APP roof membrane, complete all as specified and directed.
M&L for application of 5 layer of water proofing system on leaking roof / wall by through surface preparation opening and filling of cracks, application of absorption coat of Thermacool WP51 application of two coats of elastomeric (thermacool WP51+ cement ) waterproofing layer and topcoated with two coats of thermacool 0.3c elastomeric , waterproofing solar IR heat reflective coating having a min service life of 7 years, complete all as specified and directed.
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for (reinforcement cut as required to facilitate demolition) complete and removing the retreived debris out side MD land, complete all as specified and directed.
Supplying and fixing rotational moulded polythylene water storage tanks, double layered (ISI marked) of 2000 litres capacity (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-I, including provision of necessary fittings for connecting the overflow, drain out, inlet and outlet pipes, complete all as specified and as directed.
Disconnecting existing tanks, capacity exc 1000 ltrs and n'exc 2000 ltrs, setting aside (or lowering if required) for repair, cleaning, etc. and hoisting if required reconnecting and re-fixing in position (cleaning, repairing etc measured separately) complete all as specified and directed.
S&F Ball brass valves of size 20 mm bore high pressure, the polythene float and fly nut, screwed for iron pipe or brass frame etc, complete al as specified and directed.
S&F and mild steel framed work as in grills, greating and guard bar with end of bars shouldered and / or reveted or forged into spikes nad similar works confirming to Fe-410 and Fe-310.
M&L for injecting chemical GLYPHOSPHATE (4% concentration) of 20 ml or till refusal by making cut/injection in the stem of plant of roots at 30mm and spraying with solution 25 ml GLYPHOSPHATE (4% concentration diluted with 1 ltr of water) and removing the plant /vegetation complete all as specified and as directed.
M&L for Providing 2 to 2.50mm thick FRP chajja of approved pattern/shape/size (with sides & front drop etc), colour/pattern as of Mangalore clay tile (the FRP chajjas shall be moulded in gel coat finish, the thickness shall be 4 mm and back patti to be additionally reinforced with core matt, all resins and pigment shall be fully weatherable and UV established, core malt shall be used with GSM for extra thickness, necessary FRP covered metal), chajjas shall be fixed in position with and including 8mm dia and 125mm long split fastener bolts (Shakti or equivalent as approved by the GE) spaced not more than 45cm C/C and also filling the gaps with polysulphide sealant including necessary scaffolding/erection of working platform etc, complete all as specified and directed. Make : M/S Titan Enterprises or Advance FRP or Sintex.
Chipping, removing carefully loose/damaged concrete including plastering (total thickness exceeding 40mm but not exceeding 60mm ) from surfaces of RCC members, in any location by low impact Hammer/Breakar without damaging the structure & cleaning the surfaces with wire brush etc and disposal of debris out side MOD land complete all as specified and directed. Note : 1) Hard concrete shall not be removed by force
M&L for cleaning existing reinforcement with wire/ rotary wire brush to a shining bright finish, making the surfaces free from loose material, dirt etc complete and applying two coats of alkaline rust converting primer conforming to ASTM-B-117 of make. "Feovert" of "Krishna Conchem" OR "Roff Rust Cleaner' of 'Pidilite' OR 'Shali Rustoff' of 'STP Ltd', on rebars with time interval of 1 hour between the coats, complete all as specified and directed. (Note :- Mode of measurement: superficial area of concrete will be measured.)
M&L for carry out application of ‘Bi-polar migratory corrosion inhibitor' [Make : M/s. Krishna Conchem (EPCO KP-100) / BASF (MasterProtect®8000Cl)] on RCC surfaces, complete all as specified and directed. (Note :- Mode of measurement: superficial area of concrete will be measured.)
M&L for Anticorrosive Treatment to Reinforcement using IPNET-RB of M/s Krishna Conchem or Epoxy Zinc Primer of M/s. Dr. Fixit by application on exposed reinforcement in two coats with time interval of minimum 4 hours between each coat. The application shall be done by brush after cleaning/wire brushing to the exposed steel surfaces complete all as specified and directed . Note :- Mode of measurement: superficial area of concrete will be measured.
M&L for Epoxy bond coat of Make Fosroc (NITOBOND-EP) OR EPOXY BONDING AGENT of Dr. Fixit OR equivalent of M/s. Krishna Conchem as approved by GE over exposed concrete surfaces prior to application of any type of mortar / concrete to ensure bond between old concrete & new concrete/ new mortar by brush application, complete all as specified and directed.
M&L for providing Polymer Bonding Agent of Make M/s. Krishna Conchem (MONOBOND) OR Fosroc (NITOBOND-SBR) OR equivalent brand of Dr. Fixit,as approved by the GE followed by flexible polymer based putty ( 1cement: 1.2 finesand :20% polymer by weight of cement : water as required ) on cracks after cutting the cracks to a 'V' shaped groove upto 10 mm wide and 10 mm deep in structural RCC members , finished with spatula etc. complete all as specified and directed.
M&L for building up the profile of structural members using polymer modified mortar from M/s. Krishna Conchem (Molith PMM) OR Polymer mortar HB of Dr Fixit, while the bonding agent is still tacking upto 20mm thickness, including levelling, profiling etc, complete all as specified and directed.
M&L for building up the profile of structural members using polymer modified mortar from M/s Krishna Conchem (Molith PMM) OR Polymer mortar HB of Dr. Fixit, exceeding 20mm thick and not exceeding 40mm thick in two layers, each of equal thickness including levelling, profilling etc, complete all as specified and directed.
M&L for casting & repairing of excessively damaged distressed RCC members (exceeding 60mm in thickness) with prebatched, prepacked,single component ready to use microconcrete from FOSROC (Renderoc RG) or equivalent or Dr fixit as appoved by GE, at any level/height and at any lead or lift as directed including prefabricated water tight formwork, centering, scaffolding, also including mixing, laying, levelling, finishing, curing etc as per manufacturers specifications and all other relevant works, complete all as specified and directed. Note : Reinforcement only shall be measured and paid separately)
S&F TMT bars 10mm dia & over, cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
S&F TMT bars 6 to 8mm dia, cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
all as above but for stirrups complete all as specified and directed.
A P ENTERPRISES
SB CONSTRUCTION
S R INFRASTRUCTURE
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .