| 1 | L1₹32.5 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹34.0 L+₹1.5 L (4.68%)Rejected-Finance WARD NO 02 LAKHUWALI PO THE PILIBANGAN DISTT HANUMANGARH RAJASTHAN 335803 | HANUMANGARH | RAJASTHAN | 335803 | L2 | Rejected-Finance Not Lowest Bidder | |
| 3 | L3₹34.4 L+₹1.9 L (5.90%)Rejected-Finance NEW ABADI KISHANPURA SURATGARH 335804 DISTT SRIGANGANGAR RAJ | GANGANAGAR | RAJASTHAN | 335804 | L3 | Rejected-Finance Not Lowest Bidder | |
| 4 | L4₹34.8 L+₹2.4 L (7.25%)Rejected-Finance NURSERY SCHOOL 1 SECTOR 33 SUNCITY KURUKSHETRA ROAD KAITHAL 136027 HARYANA | KAITHAL | KAITHAL | HARYANA | 136027 | L4 | Rejected-Finance Not Lowest Bidder | |
| 5 | L5₹36.4 L+₹3.9 L (12.1%)Rejected-Finance | L5 | Rejected-Finance Not Lowest Bidder |
Tender Value
₹48.5 L
EMD Value
₹97,000
Closing Date
3 Dec 2022, 6:00 pmClosed
GE ARMY SURATGARH
SURATGARH MIL STN
Repair to sunken floor sanitary, plumbing fitting, flooring, joinery, masonry and connected works in Married and OTM Accn under AGE B/R-I at Suratgarh Mil Stn
2022_MES_560851_1
GE (A) SOG - 65/22-23
Open Tender
Civil Works
Item Rate
270 days
SURATGARH
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE ARMY SURATGARH
₹97,000
Yes
16 Dec 2022
1 Nov 2022
5 Dec 2022
1 Nov 2022
3 Dec 2022
15 Nov 2022
Amount
Demolition of plain cement concrete in ground floor and pavings not exc 15 cm thick (below or above ground level) including floor tiles of any description complete all as specified and directed by Engineer-in-charge.
Demolition of brick work, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed by Engineer-in-charge.
Demolition of stone slabs and tiles of any description or thickness in floors, aprons etc, laid, bedded, jointed and pointed in any mortar complete all as specified and directed by Engineer-in-charge.
Demolition of cement concrete in sunken portion including floor complete all as specified and directed by Engineer-in-charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off the premises complete all as specified and directed by Engineer-in-charge.
Dismantling bricks (laid flat or on edge) or brick tiles on roof terrace, in floors, channels, kerbs, aprons etc laid dry or laid dry and pointed and removing from site complete all as specified & directed by Engineer-in-charge.
Dismantling of cast iron drain pipe of 100mm bore, jointed in CM and taking out from trenches, if required complete all as specified and as directed by Engineer-in-charge. Note :- Excavation & earthwork shall be measured and paid separately
Dismantling of cast iron drain pipe of 75mm bore, jointed in CM and taking out from trenches, if required complete all as specified and as directed by Engineer-in-charge. Note :- Excavation & earthwork shall be measured and paid separately
Taking down eaves gutters and rain water pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc (measured overall as fixed along the centre line over fittings and accessories) complete all as specified and directed by Engineer-in-Charge.
Taking down steel window / ventilator of any description and of any type with or without guard bars and making good the disturbed portion complete all as specified and directed by Engineer-in-charge.
Taking down aluminium door / window / ventilator of any description and of any type with or without guard bars and making good the disturbed portion complete all as specified and directed by Engineer-in-charge.
Taking down cement plaster or cement lime plaster on stone surface/brick surfaces of walls including raking out joints hacking for key scrubbing down with water etc complete all as specified and directed by Engineer-in-charge.
Taking down chowkat or frame with shutters including fitting and fixtures area not exc 1.5 Sqm each (without taking off the wooden shutters from the frame) including cutting holes for hold fasts and making good disturbed surface with cement mortor or PCC after fixing new chowkats complete all as specified and directed by Engineer-in-charge.
Taking down chowkat or frame with shutters including fitting and fixtures area exc 1.5 Sqm but not exc 4 Sqm each (without taking off the wooden shutters from the frame) including cutting holes for hold fasts and making good disturbed surface with cement mortor or PCC after fixing new chowkats complete all as specified and directed by Engineer-in-charge.
Taking down shutters of any description exc 1 Sqm and not exc. 2 Sqm each complete all as specified and as directed by Engineer-in-charge.
Taking down existing steel rolling shutters of area not exc 10 Sqm with all connecting items and repair the lath, hood covers, ball bearings, helical wire spring, lock plates, bracket plates, shaft rods, guide channels of steel rolling shutters and locking arrangements, including greasing, tightening, oiling, welding etc. wherever required, complete to make in serviceable condition and applying one coat of synthetic enamel paint including preparation of old painted surfaces and refixing in the same opening complete all as specified and directed by Engineer-in-charge.
Taking down steel rolling shutters of garrages / stores area exc 10 sqm but not exc 30 sqm each, straightening the frame, bent up steel sheet , refixing the MS steel shutter in the same opening by grouting pintel hinges in PCC 1:2:4 incl MS pingel round bar of dia 20mm, greasing etc complete all as specified and directed by Engineer-in-charge.
Removal of excavated soil/ material to a distance exc 250 metre and not exc 500 metre and depositing where directed at a level not exc 1.50 metre above the starting point complete all as specified and directed by Engineer-in-charge.
M&L for preparation sunken surfaces by cleaning of and removal of loose concrete and filling cracks with polymer modified mortar using Dr. Fixit Pidicrete URP or equivalent in Forsoc and other approved make and applying 2 coats of Dr. Fixit Bath seal WPC in suken areas and laying a protective plaster in 10mm thickness in cement mortar (1:3) admixed with Dr. Fixit Pidicrete LW + @ 220ML per bag of cement applying mix of cement water in the ratio 1:1:5 by volume using DR FIXIT PIDICRETE URP chemical on floor and vertical surface of sunken floor as per manufacturers instructions complete all as specified and directed by Engineer-in-charge Note :- Supply only liquid water proofing compound shall be measured and paid for seprately under respective items of BOQ.
Supply only integral water proofing compound (ISI marked) complete all as specified and directed by Engineer-in-charge.
M&L for PCC (1:5:10) type E-2 using 40 mm graded brick aggregate in, filling and mass concrete as in sunken portion complete all as specified and as directed by Engineer-in-charge.
M & L for PCC (1:2:4) type B-0 using 12.5mm graded stone aggregate as in padding / levelling concrete on top of roofs, roof kerbs or mud stops, coping, band, bed plate rounded or chamfered on edges using water proofing compound and including necessary form work complete all as specified and directed by Engineer-in-charge Note :- Cost of WPC is included in the unit rate of this item. Nothing extra shall be paid on this account.
M&L for cement concrete 1:2:4, type B-1 (using 20mm graded stone aggregate) as in lintels upto 1.5 metre clear span, cills, steps, siesmic and other similar bands, plinth courses, string courses, lacing courses, coping, parapets and railing upto 60cm height, copings bed block, roof kerbs or mud stops, kerb stone, kneelers, apex stones, bed plates, surface channels and drains, benching, water troughs and the like including weathering, slightly rounded or chamfered angles and throatings etc.including necessary form work complete all as specified and directed by Engineer-in-Charge.
M&L for Brick work with sub class ‘B’ old size burnt bricks, straight or curved on plan exc 6m mean radius built in cement mortar (1:6) complete all as specified and directed by Engineer-in-charge.
M&L for Brick work with fly ash bricks, straight or curved on plan exc 6m mean radius built in cement mortar (1:6) complete all as specified and directed by Engineer-in-charge.
S&F 35mm thick factory made glazed and skeleton shutters made of second class hard wood (Bonsum/Hollock), open rebated and prepared to receive glass, gauze etc (without sash bars) edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass etc., sizes of members of shutters as specified in SSR Part I Section 8 Clause 8.24 (a) kiln seasoned and chemically pressure treated fixed to chowkat complete all as specified and directed by Engineer-in-charge.
S&F 35 mm thick factory made plain framed, panelled shutter (any number of panels) with lock rail and panel of 9mm thick BWP commercial ply or 12 mm thick veneered particle board with commercial veneering on both faces. The size of rail and styles as per IS : 1003 (Part-I), kiln seasoned and chemically pressure treated using second class Hard Wood (Hollock or Bonsum) complete all as specified and directed by Engineer-in-charge.
S&F factory made solid PVC door frame of size 50mm x 47mm made out of 5mm thick one side prelaminated PVC sheet reinforced with MS square tube and edges painted to match the prelaminated sheet complete all as specified & shown in relevant drawing of item No. 08095 to 8097 in MES Schedule (Part-II) and directed by Engineer-in-Charge
S&F 30mm thick factory made solid core PVC door shutter (style) consisting of frame made out of mild steel tubes for top and bottom rails, mild steel frame shall be covered with heat moulded plain colour PVC sheet, 'C' channel having PVC sheet strip of 20mm width stuck inside with solvent cement for styles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail and bottom rail; panelling of plain colour PVC sheet to be fitted in mild steel frame welded/ sealed to the styles and rails with suitable PVC sheet beading and joined together with solvent cement, complete, all as specified & shown in relevant drawing of item No. 08080 in MES Schedule (Part-II) and directed by Engineer-in-Charge.
S&F 150 mm long aluminium anodized barrel tower bolts of extruded section (ISI marked) complete all as specified and directed by Engineer-in-charge.
S&F 200 mm long mild steel barrel tower bolt stove enamelled black with bright bolt (ISI marked) complete all as specified & directed by Engineer-in-Charge.
S&F 100mm size mild steel butt hinges cold rolled medium weight (ISI marked) complete all as specified & directed by Engineer-in-Charge.
S&F 100mm size butt hinges of extruded aluminium alloy with galvanized mild steel hinge pin, anodized type B-21 (ISI marked) complete all as specified and directed by Engineer-in-charge.
S&F 300mm long aluminium alloy anodised sliding door bolts with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminium alloy (ISI marked) complete all as specified & directed by Engineer-in-Charge.
S&F 125 mm long mild steel pressed handle, oval type, stove enameled black (ISI marked) complete all as specified and directed by Engineer-in-charge.
S&F 125mm long extruded aluminium handles, anodised, fabricated type (ISI marked) complete all as specified and directed by Engineer-in-Charge
S&F 150mm long extruded aluminium handles, anodised, fabricated type (ISI marked) complete all as specified and directed by Engineer-in-Charge
S&F in repair floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring overall length of cover plate 140mm (ISI marked) complete all as specified and directed by Engineer-in-Charge.
S&F in repair aluminium (Die cast) body door closer hydraulically regulated, designation No. 3 universal type, suitable for door shutters of 851 to 1000mm in width and weight between 61 to 80kg (ISI marked) complete all as specified and directed by Engineer-in-Charge.
S&F in repair double action floor spring hydraulically regulated made up of minimum 1.25mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made out of mild steel heavy duty & fixed (ISI marked) complete all as specified and directed by Engineer-in-Charge.
S&F galvanized mild steel wire cloth 0.56 mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks or galvanized wire staple complete all as specified and directed by Engineer-in-charge.
S&F in repair galvanized mild steel wire cloth 0.56 mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks or galvanized wire staple complete all as specified and directed by Engineer-in-charge.
S&F in repairs powder coated mild steel drapery rod of 20 mm inner dia (in lengths as directed) of approved colour with & including decorative finial at both ends and pair of powder coated mild steel brackets fixed at both ends with PVC rawl plug & steel screws on walls/beam, including PVC curtain rings of matching colour @ 10cm C/C all as specified & as directed.
S&F in repair Mild Steel 300mm, ordinary rat tail rod patttern springs including roller & roller plate fixed to wooden frame or welded to steel frame making suitable cut out in wall and making good in CM 1:4 complete all as specified and directed by Engineer-in-charge.
S&F mild steel cupboard shutter with frame, Godrej Pattern, made out of 0.71mm thick (22 guage) mild steel sheet including chromium plated MS handle with proper locking arrangement (brass mortice lock, vertical type, size 65mm, 4 Levers with escutcheon plates & two keys) with & including two coats of spray painting with synthetic enamel paint of approved tint over a coat of red oxide primer including fixing with 6 Nos 12mm dia bolt 150 mm long grouted in brick wall/concrete including making good the disturbed surfaces as original complete all as specified and as directed. Note : - The measurement for payment purpose shall be taken of flat area of front elevation and not girthwise. No other allowance for sides, folded portion, etc shall be admissible. The quoted rate shall be deemed to include this provision.
S&F mild steel round bars as in window guard bars incl necessary welding and a shop coat of zinc primer confirming to Fe-290 (Gde-E-165) complete all as specified and directed by Engineer-in-Charge.
S&F factory made steel ventilator with top hung shutter including hinges, steel peg stay, handle including one shop coat of Zinc Chromate primer and cutting holes in brick wall built in cement mortar for inserting lugs and making good dismantled portion in cement mortor (1:3) or cement concrete (1:2:4) type B-I complete all as specified and directed by Engineer-in-charge.
S&F pressed steel frames for door of size 125x60mm with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc made out of mild steel sheet of 1.25mm thickness complete all as specified and as directed by Engineer-in-charge.
S&F pressed steel frames for door of size 105x60mm with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc made out of mild steel sheet of 1.25mm thickness complete all as specified and as directed by Engineer-in-charge.
S&F anodised aluminium frames powder coated (thickness of powder coating shall not less than 50 micron) for doors, windows, ventilators with one or more rebates including jointing cleats for fixing etc complete all as specified and directed by Engineer-in-Charge.
M&L for aluminium grill mesh made out of 6mm dia having girth not exc 25mm both ways fixed with aluminium cleat to window frame complete all as specified and directed by Engineer-in-Charge.
S&F anodised aluminium doors shutters powder coated (thickness of powder coating shall not less than 50 micron) sliding / openable having aluminium sections weighting 0.55 Kg/RM including necessary jointing cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, 100mm size, 4 levers brass mortice lock vertical type (01 No), hinges, anodised aluminium snap beading, screws complete all as specified and directed by Engineer-in-Charge.
S&F anodised aluminium window / ventilators shutters powder coated (thickness of powder coating shall not less than 50 micron) side hung type, without sash bars having aluminium sections weighting 0.55 Kg/RM including necessary jointing cleats, glazing clips, anodised aluminium snap beading, screws, rubber neoprene packing including anodised aluminium fitting such as peg stay 150mm long (1 No), hinges type B21 100mm size (2 Nos), suitable handle (1No) complete all as specified and directed by Engineer-in-Charge.
M&L for machine cut Kota stone slab flooring 18 to 20mm thick (minimum size 550mm x 550mm or size as directed) laid over & including screed bed or bedding layer of 15mm thick in CM (1:6) and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing complete all as specified and directed by Engineer-in-charge.
M&L for machine cut Kota stone slab 18 to 20mm thick (minimum size 550mm x 100mm or size as directed), on vertical surfaces such as dado, skirting, raiser of steps etc. laid over & including rendering 10mm thick in CM (1:4) and jointed with grey cement slurry mixed with pigment to match the shade of the slab including cutting, grinding, rubbing and mirror polishing complete all as specified and directed by Engineer-in-charge.
M&L for cutting or grinding surfaces of old kota stone flooring, skirting, dados etc with car boredom stone by hand or grinding machine, dusting off the surfaces after grinding and finally washing the surface clean with oxalic acid solution and polishing with bees wax polish complete all as specified and directed by Engineer-in-charge.
Demolition of mud phuska in roof any thickness including plastering & leeping (whether full thickness removed or only part thereof) complete all as specified and directed by Engineer-in-charge.
M&L for cleaning of all loose dirt and dust from roof and priming the surface with one coat of cold applied bituminious primer @ 0.40 Kg/Sqm conforming to IS:3384 and applying a layer of APP based polymeric membrane not less than 3 mm thick, weighing not less than 3.5 Kg/Sqm, reinforced with polyester non woven fabric (weighing not less than 150 gms/Sqm) and upper side of membrane thermally insulated with white gravel finish uniformaly embedded during manufacturing process. It shall be laid by torch application having side over lap 75 mm and at the end 100 mm, all overlaps and joints shall be sealed by torch application. For parapet, membrane shall be taken to a height of minimum 60 cm and inserted inside the parapet in a groove to a depth of 65mm. The same shall be furnished by a membrane flashing. Note : The net area of water proofing treatment shall be measured without any extra allowance for laps & portion inserted in groove which shall be deemed included in the quoted rates.
M&L for applying evenly one coat of industrial bitumen 85/25 @ 1.20 Kg per Sqm including cleaning of surface complete all as specified and directed by Engineer-in-Charge.
M&L for 40mm thick brick tiles laid on and joints grouted flush in cement mortar (1:3) mixed with 5% of crude oil by weight of cement complete all as specified and directed by Engineer-in-charge.
All as per serial item No. 60 here-in-above but except brick tiles. Note : Old serviceable brick tiles retrieved from serial item No 6 of BOQ here-in-before shall be used under this item.
M&L for 18-20mm thick Granite (of any type) slab of approved shade as in cooking platforms, steps, jambs, pillars, window cills and the like etc, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match with shade of Granite stone including cutting, grinding and polishing (mirror polish i.e. full granite polish as per local trade practice) over & including 15mm thick screed bed (bedding layer) in CM (1:6) complete all as specified and directed by Engineer-in-charge. Note : The exposed edges of granite stone slab shall be made full round & polished to mirror finish and rate quoted shall deemed to include this provision.
M&L for 50 mm thick PCC (1:3:6) type C1 using 20 mm graded crushed stone aggregate as in plinth protection, finished fair and even complete all as specified and directed by Engineer-in-charge. Note :- Plinth protection shall be laid to slope (1 in 30) in bays not exceeding 3 metre in length and joints of 6 mm wide and 10 mm deep shall be provided along the wall and bays and same shall be filled with sealing compound grade B. Cost of ceiling compund is included in the unit rate of this item
M&L for 40mm thick PCC (1:2:4) type B1 using 20mm graded crushed stone aggregate as in flooring finished even and smooth without using extra cement complete all as specified and as directed by Engineer-in-charge.
M&L for 40mm thick PCC (1:2:4) type B1 using 20mm graded crushed stone aggregate as in flooring finished even and smooth without using extra cement complete all as specified and as directed by Engineer-in-charge. Note :- PCC shall be laid in alternate bays in panels of size not exc 1.2m x 1.2m and joints shall be filled with bitumen mastic (1:3). Quoted rate shall deemed inclusive for same.
S&F plastic dividing strips 1.5mm thick 28mm wide inserted in position conforming to design complete all as specified and directed by Engineer-in-charge.
M&L for non skid ceramic joint free coloured tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm as in floors, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 15mm thick screed bed in cement & sand mortar (1:6) complete all as specified and directed by Engineer-in-charge.
M&L for non skid ceramic joint free coloured tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm as in floors, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 15mm thick screed bed in cement & sand mortar (1:6) complete all as specified and directed by Engineer-in-charge.
M&L for non skid joint free ceramic coloured tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm on vertical surfaces such as dado, skirting etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 10mm thick rendering in cement & sand mortar (1:4) complete all as specified and directed by Engineer-in-charge.
M&L for glazed ceramic tiles (coloured) 450mm x 350mm x 7mm thick on vertical surfaces such as dado, skirting etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 10mm thick rendering in cement & sand mortar (1:4) including necesary cutting as per site requirment complete all as specified and directed by Engineer-in-charge.
M&L for vitrified ceramic light shade (as approved) coloured tiles 10mm thick (square / rectangular), polished, area of each tile not exceeding 0.36 sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 15mm thick screed bed in cement & sand mortar (1:4) complete all as specified and directed by Engineer-in-charge.
M&L for 10mm thick vitrified ceramic light shade (as approved) coloured tiles (square / rectangular), polished, area of each tile not exceeding 0.36 sqm as on vertical surfaces such as dado, skirting etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 10mm thick rendering in cement & sand mortar (1:4) complete all as specified and directed by Engineer-in-charge.
M&L for 15mm thick rendering in cement mortar (1:4) on fair faced or on other than fair face surface of brick masonary or concrete surface of walls, finished even & smooth without using extra cement complete all as specified and directed by Engineer-in-charge.
M&L for 15mm thick rendering in cement mortar (1:6) on fair faced or on other than fair face surface of brick masonary or concrete surface of walls, finished even & smooth without using extra cement complete all as specified and directed by Engineer-in-charge.
M&L for 10mm thick rendering in cement mortar (1:3) on brick or concrete surface of ceiling, finished even & smooth without using extra cement complete all as specified and directed by Engineer-in-charge.
M&L for rough cast finish plaster with a mixture consisting of crushed stone or fine gravel aggregate mixed with coarse sand and cement in the ratio of 1:1:1 over & including 12mm thick rendering in cement mortar 1:3 on fair faces of brick masonry or concrete surfaces of walls complete all as specified and directed by Engineer-in-charge.
M&L for preparation of newly plastered surfaces of wall and applying three coats of white wash complete all as specified and directed by Engineer-in-charge.
M&L for preparation of newly plastered surfaces of ceiling and applying three coats of white wash complete all as specified and directed by Engineer-in-charge.
M&L for preparation of newly plastered surface of walls & applying two coats of cement base paint of approved shade/tint and filling cement based putty in cracks complete all as specified and directed by Engineer-in-charge.
M&L for preparation of old decorated, plastered or pointed surfaces of ceiling by brooming down or steel wire brushing,scrapping down smoke soot moulds, moss and efflorescent, salts and treating oil & greasy spots etc and applying one coat of white wash complete all as specified & directed by Engineer-in-Charge.
M&L for preparation of old decorated, plastered or pointed surfaces of wall by brooming down or steel wire brushing,scrapping down smoke soot moulds, moss and efflorescent, salts and treating oil & greasy spots etc and applying one coat of white wash complete all as specified & directed by Engineer-in-Charge.
M&L for preparation of old decorated, plastered or pointed surfaces of wall by brooming down or steel wire brushing,scrapping down smoke soot moulds, moss and efflorescent, salts and treating oil & greasy spots etc and applying two coat of white wash complete all as specified & directed by Engineer-in-Charge.
M&L for preparation of old decorated, plastered or pointed surfaces of wall by brooming down or steel wire brushing,scrapping down smoke soot moulds, moss and efflorescent, salts and treating oil & greasy spots, washing, rubbing down and stopping of distempered surface, filling of cracks etc and applying one coat of oil bound distemper complete all as specified & directed by Engineer-in-Charge.
M&L for preparation of old decorated, plastered or pointed surfaces of wall by brooming down or steel wire brushing,scrapping down smoke soot moulds, moss and efflorescent, salts and treating oil & greasy spots, washing, rubbing down and stopping of distempered surface etc and applying two coat of distemper oil emulsion complete all as specified & directed by Engineer-in-Charge.
M&L for preparation of new plastered and unplastered surfaces of wall and applying two coats of oil bound distemper including chalk whitening preparatory to distempering complete all as specified & directed by Engineer-in-Charge.
M&L for complete removal of existing treatment from old plastered surfaces like lime, distemper, plastic paint, cement base paint including scrapping down smoke soot, moulds, moss, efflorscent salts, trading oil, greasy spots using mechanical grinding machine and washing of old surface with water of wall, preparation of surfaces and applying two coats of oil bound distemper (OBD) over a coat of appropirate primer over and including 3mm thick layer of wall putty (Make J K or Birla) complete all as specified & directed by Engineer-in-Charge.
M&L for complete removal of existing treatment on wall like lime, distemper, cement base paint etc including scrapping down smoke soot, moulds, moss efflorescent salts, trading oil, greasy spots using mechanical grinding machine and washing of old surface with water preparation of surfaces and applying two coat of exterior emulsion paint over a coat of exterior primer complete all as specified & directed by Engineer-in-Charge. Make : Asian Paints (Brand - ACE) / Berger Paint (Brand - Shingar) / Nerolac Paint (Brand - Total) or equivalent in makes mentioned in Appendix 'A' here-in-after. Note :- After complete removal of existing treatment surfaces shall be inspected by the Engineer-in-Charge and further each coat of exterior paint and primer shall be applied only after passed by Engineer-in-Charge.
M&L for complete removal of existing treatment from old plastered surfaces like lime, distemper, plastic paint, cement base paint including scrapping down smoke soot, moulds, moss, efflorscent salts, trading oil, greasy spots using mechanical grinding machine and washing of old surface with water including filling of cracks and applying two coats of cement base paint shade/tint over a coat of white wash on walls complete all as specified and directed by Engineer-in-charge.
M&L for preparation of old decorated plastered or unplastered surfaces of walls by brooming down or steel wire brushing,scrapping down smoke soot mulds, moss and efflorescent, salts, filling of cracks etc and applying a coat of cement based paint complete all as specified & directed by Engineer-in-Charge.
M&L for writing letters or figures (Block. Roman, Italic or Indian) not exceding 30 cm high complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of new wooden or wood based surfaces of any description not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of old painted wooden or wood based surfaces of any description not otherwise described over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of new steel surfaces of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engineer-in-charge.
M&L for preparation of old painted steel and iron surfaces of any description not otherwise described over 10 cm width or girth and applying one coat of synthetic enamel paint of approved tint complete all as specified and directed by Engineer-in-charge.
Hacking out old broken glass any thickness, size, quality or description from wooden / metal frame and punching or drilling out old glazing pins/spring clips complete all as specified and directed by Engineer-in-charge.
S&F 4mm thick sheet glass ordinary quality and glazing with oil putty in square not exc 0.5 sqm in each pane including painting / oiling to new putty to match with the existing/new surfaces, complete all as specified and as directed.
S&F 4mm thick figured glass pin head type and glazing with oil putty in square not exc 0.5 sqm in each pane complete all as specified and directed by Engineer-in-charge.
S&F 5.5mm thick sheet glass ordianary quality glazing with oil putty in squares, area exceeding 0.50 Sqm in each pane area complete all as specified and directed by Engineer-in-Charge .
Taking up or down 15mm dia, steel tubing & connections including cleaning for refixing or removal to store complete all as specified and directed by Engineer-in-Charge.
S&F 15mm bore galvanized steel water tubing medium grade with & including all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and directed by Engineer-in-charge.
Fixing only 15mm bore old galvanised steel water tubing including cleaning with & including new fittings and fixed complete to walls and ceilings or laid in floors in new or old position complete all as specified and directed by Engineer-in-charge. Note :-GI tubing retrieved vide item No 99 shall be used under this item
Taking up or down 20mm dia, steel tubing & connections including cleaning for refixing or removal to store complete all as specified and directed by Engineer-in-Charge.
S&F 20 mm bore galvanized steel water tubing medium grade with & including all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and directed by Engineer-in-charge.
Fixing only 20mm bore old galvanised steel water tubing including cleaning with & including new fittings and fixed complete to walls and ceilings or laid in floors in new or old position complete all as specified and directed by Engineer-in-charge. Note :-GI tubing retrieved vide item No 102 shall be used under this item
S&F in repair 15mm bore brass chromium plated shower rose with or without swivel joints, any size, including fixing to steel pipe or union with shower arm 15mm size, 195mm long iwht bend of 45 degree with flange complete all as specified and directed by Engineer-in-charge.
S&F in repair 450mm long PVC connection suitable for 15 mm bore with PTMT nuts on both sides complete all as specified and directed by Engineer-in-charge.
S&F in repair grating doom 100mm dia of PTMT with waste hole (minimum weight 25 grams) complete all as specified and directed by Engineer-in-Charge.
S&F in replacement HDPE PVC lid (cover) for 500 Ltr capacity water storage tank complete all as specified and directed by Engineer-in-Charge.
S&F in replacement HDPE PVC lid (cover) for 1000 Ltr capacity water storage tank complete all as specified and directed by Engineer-in-Charge.
S&F in replacement rotational moulded polyethylene water storage tank ISI Marked (cylindrical vertical double layered with closed top) hoisted and fixed in position of capacity 500 litres including ball brass valve, high pressure with polythene float and flynut screwed for 20 mm dia GI pipe, 25mm bore GI washout pipe 15 cm long fitted with check nut, 20mm bore over flow pipe 1.50 metre long fitted with brass anti-mosquito nest coupling at the end of over flow pipe & 15mm bore GI air vent pipe 1.30 metre long fitted with tee at the end of air vent pipe (All GI pipes shall be medium grade) complete all as specified and directed by Engineer-in-Charge.
All as per Srl item No. 110 here-in-before but 1000 ltrs capacity
All as per Srl item No. 110 here-in-before but 2000 ltrs capacity
S&F in repair 15 mm bore bib tap, cast copper alloy chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed by Engineer-in-charge.
S&F in repair fancy type pillar tap, cast copper alloy with capstan heads, chromium plated, screwed down high pressure, with or without lettered ‘Hot’ or ‘Cold’ with long screwed shankS&Fly nuts, screwed suitable for iron pipes of 15mm bore complete all as specified and directed by Engineer-in-charge.
S&F in repair Ball brass valve, high pressure, with polythene float and flynut complete, screwed for iron pipe 20mm bore or brass ferrule and fixed complete all as specified and directed by Engineer-in-Charge.
S&F in repair 15mm bore stop valve, cast copper alloy, screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions complete all as specified and directed by Engineer-in-charge.
S&F in repair 15mm dia stop cock cast copper alloy, fancy type with, chromium plated long shank and cup (concealed type) with crutch or butterfly handle screwed down high pressure, screwed both ends for iron pipe complete all as specified & directed by Engineer-in-charge.
S&F in repair 15mm dia stop cock cast copper alloy, angular type with, chromium plated long shank and cup with crutch or butterfly handle screwed down high pressure, screwed both ends for iron pipe complete all as specified & directed by Engineer-in-charge.
S&F in repair vitreous china wash basin white, flat back of size 550x400mm including including a pair of cast iron brackets embedded in PCC 1:3:6 type C-1 blocks of size 10 x 7.5 x15 cm with & including 32 mm dia PVC waste pipe, 32mm dia PTMT waste coupling half or full thread (minimum wt 45 grms) flange end bedded in red lead cement & other end fixed to waste pipe and including brass chromium plated fancy type pillar tap, screwed suitable for iron pipes of 15mm bore complete all as specified and directed by Engineer-in-Charge.
S&F in repair vitreous china squatting pan Orissa pattern, white of size 580x440mm with integral foot rests (excluding flushing cistern and flush pipe) including cast iron 'P' or 'S' trap, PCC filling and connection to trap and flushing pipe, antisyphonage pipe etc complete all as specified and directed by Engineer-in-charge.
S&F in repairs vitreous china wash down water closet pan (Pedestal pattern), white including connection to drain (or outgoing pipe) and to flushing pipe, anti-sypohonage pipe etc. & with plastic WC seat cover white closed pattern with flat bottom and cover and mild steel chromium plated or aluminized hinging device and jet spray complete all as specified & as directed by Engineer-in-charge.
S&F in repair 10 litre capacity PVC valveless symphonic action type low level flushing cistern (ISI marked) including 32 mm dia PVC flush pipe connected to water closet with inlet, ball valve, float and handle complete all as specified and directed by Engineer-in-charge.
S&F in repairs plastic water closet seat, white, closet pattern with flat bottom and cover and mild steel chromoum plated or aluminised hinging device complete all as specified and directed by Engineer-in-Charge.
S&F vitreous china full stall type, flat back urinal white including providing & fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with & including 60 mm long brass screws, pointing around urinal back in cement, with & including PTMT grating and union for discharge pipe including waste pipe of polythelene of low or high density or PVC 32mm dia complete all as specified and directed by Engineer-in-charge.
S&F in repairs PVC waste pipe 32 to 40mm bore suitable for WHB or Sink complete all as specified and directed by Engineer-in-charge.
S&F in repair jet spray chromium plated brass for ewc with & including PVC connection 600mm long suitable for 15mm bore GI pipe complete all as specified & directed by Engineer-in-Charge.
S&F in repair 75mm dia PVC (SWR) floor trap, plain with grating including jointing with solvent cement including jointing to waste pipe fixed in cement concrete (1:2:4) type B-1 using 20mm graded stone aggregate complete all as specified and directed by Engineer-in-Charge.
S&F 110mm bore PVC (SWR) pipes single socketed in any length jointed with adhesive fixed to walls fixed with and including requisite Number of clamps made out of flat iron 25x4mm complete all as specified and as directed by Engineer-in-charge.
S&F 75mm bore PVC (SWR) pipes single socketed in any length jointed with adhesive fixed to walls fixed with and including requisite Number of clamps made out of flat iron 25x4mm complete all as specified and as directed by Engineer-in-charge.
S&F 110mm bore PVC (SWR) pipes single socketed in any length with solvent joints laid In trenches or in floors complete all as specified and directed by Engineer-in-charge.
S&F 75mm bore PVC (SWR) pipes single socketed in any length with solvent joints laid In trenches or in floors complete all as specified and directed by Engineer-in-charge.
S&F 110 mm bore PVC (SWR) bends any radius jointed with adhesive with oval access door complete all as specified and as directed by Engineer-in-charge.
S&F 75 mm bore PVC (SWR) bends any radius jointed with adhesive with oval access door complete all as specified and as directed by Engineer-in-charge.
S&F 75mm bore PVC (SWR) vent cowl complete all as specified and directed by Engineer-in-Charge
S&F 110mm bore PVC (SWR) reducers 110mm to 75mm complete all as specified and directed by Engineer-in-Charge
S&F 75mm bore PVC (SWR) junction,single (single T) equal or unequal complete all as specified and directed by Engineer-in-Charge"
M&L for removing loose ceiling plaster completely, cleaning and dripping mortars and curing of effected surface area, cleaning well expossed reinforcement and applying two coats of anti-corrosive paint to it, supply and fixing mild steel XPM mesh of size 25mm x 25mm (wire dia min. 2mm) to the effected ceiling surface either by welding with exposed reinforcement or by stapling nails or screw or tie with reinforcement, applying cement slury and 25mm thick microphone of 1:1:1 using 6mm graded aggregate and cuting it for 3 days and then making well finish the surface using cement mortar 1:3 complete all as specified and directed by Engineer-in-charge. -------------------------------------------------------------------- Note :- A sum of Rs. 92100/- will be deducted on account of credit for dismantled/ demolished / taken down material. Please refer details on Srl Page No. 32 & 33 (Schedule of Credit) of Tender documents.
Gill Construction Co
M/s JUGAL KISHORE MISHRA AND SONS
godara construction company
AK CONSTRUCTION
M/S GODARA CONSTRUCTION CO.
HARPREET SINGH CONTRACTOR
Gupta Suppliers
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .