SH. ANIL KUMAR SINGH, SE, EUDC-1 GZB
A BLOCK HYDEL COLONY KAVINAGAR GHAZIABAD
For the work of Shifting of Pole and Line, Electrification AND giving New connection to various consumers in the area of 11 KV LT South Side, Ghaziabad by running Tender (Deposit Scheme) under the jurisdiction of EE, 11 KV LT South Side, Ghaziabad
2025_PVVNL_1095045_2
26/2025-26/EUDC-1/GZB
Open Tender
Electrical Works
90 days
GHAZIABAD
PLEASE PREFER TENDER DOCUMENTS
2 documents required · 2 mandatory
₹3,540
SUPERINTENDING ENGINEER, EUDC-1 GHAZIABAD
₹50,000
20 Dec 2025
4 Dec 2025
10 Dec 2025
4 Dec 2025
10 Dec 2025
4 Dec 2025
Carriage of PCC Pole 8.5 mtrs. Long from Electricity store center, Meerut Road, Ghaziabad .E. Store to site of work with loading and unloading at both ends on Kachha Packka road. within 50 KM.
Carriage of ST Pole 11 mtrs.&13mtr Long from Electricity store center,Meerut Road, Ghaziabad/J.E. Store to site of work with loading and unloading at both ends on Kachha Packka road. within 50 KM.
Carriage of 11KV&33 kv CT/PT Unit from Electricity store center,Meerut Road, Ghaziabad to site of work with loading and unloading at both ends on Kachha Packka road. within 50 KM.
Erection & Fixing of PCC Pole 8.5 mtr. long in LT. line after digging of suitable pits including fixing of requisite accessories as per RESPO Drawing/Norms by providing L.T. Pin Clamps, M.S. Flat of size 50x6 & Schacle Insulator of size 75x90mm, with proper size nuts and bolts.
Erection and fixing of double pole on ST Pole 11 mtr. long &13 mtr long with fixing of M.S. Top & Dropper Channel, M.S. S/S Angle, E-Bracket, 11 KV Pin insulator with Pin, Disc Insulator with Disc fitting as per RESPO Drawing/ Norms by providing top and dropper clamps made of M.S. Flat of size 50x6 mm with proper size nuts and bolts.
Mounting, Placing and connecting from LT/HT side of 11KV,&33 kv CT/PT Units as per RESPO Norms.
Laying of 140/160mm O/D PN-4PE-80 PN-4 grade UV stabilized HDPE pipe as per IS of 6meter, for laying of underground Cable as per RESPO/Norms, including cost of above HDPE pipe.
Laying of 11 KV and 33KV XLPE Cable underground (400x2=800 Double Circuit) into HDPE Pipe Trechless Machine , spare cable shall be left in the loop shape at both ends as per RESPO/Norms.
Laying of 11 KV and 33KV XLPE Cable underground (400x2=800 Double Circuit) with Sand Brick, spare cable shall be left in the loop shape at both ends as per RESPO/Norms.
Road restoration charge for pucca road/footpath crossing as per RESPO/Drawing Norms.
Laying of 11KV AB Cable of various capacity and completion work properly, as per RESPO/Norms.
Laying of 11 KV XLPE Cable (3x35-3x70-3x120-3x185 sq mm ) and complition work properly as per RESPO/Norms
Laying of 33 KV XLPE Cable (3x120&3X300 3x400 sq mm ) and complition work properly as per RESPO/Norms DOUBLE 350X2=700
Laying of LT ABC of various capacity and completion work properly, as per RESPO/Norms.
Erection & Fixing of Distribution Box on pole by provding 02 Nos. D/B Clamps & proper size nut & bolts.
Providing and fixing of Dead End Clamp with Eye Hook, as per RESPO/Norms.
Making and filling of 11/33 KV Cable Jointing Kit, I/D, O/D, S/T type, after duly plumbing and taping of suitable XLPE Cable, providing, fixing and crimping of proper size good quality lugs, including cost of lugs and tape etc., as per RESPO Norms. Jointing Kit Provide by department.
Installation of 11 KV & 33kv Metering Cubical & CT/PT Complete work as per RESPO Norms.
Fabrication & Fixing of T-Channel on pole by providing Holding Clamps, F-Clamps & Proper size nuts & bolts, as per RESPO/Norms.
Grouting & fixing of stay rods (20x1800)mm including all work of excavation, cement concrete in size (0.60x0.60x0.30)m in ratio 1:4:8 cement, sand, 40mm brick ballast as per drg. Including back filling, proper ramming etc and fixing tightening & nozzling of stay wire with stay rod with the poles of required tension as per drawing as per RESPO Drawing/Norms by providing all grouting material and stay clamp made of M.S. Flat of size 50x6mm with proper size bolts & nuts & loops.
Earthing of supports with MS earth Rod of (20x2500)mm long including excavation of pit and driving M.S. Rod 3.0 M apart from support and 0.5m below the ground level and connection below the earth electrodes with the help of G.I. wire & earthing lugs as per RESPO Drawing/Norms by providing proper size nuts & bolts.
Grouting of ST/PCC supports in CC 1:4:8 (Cement, sand & 40mm brick ballast)Grouting will be done in the block of size (450x450)mm x1/6th of full length of the support, up to ground level, 300mm plinth above the ground level with CC 1:3:6 (Cement, core sand and Stone grit) with mufting as per drawing, work includes back filling & proper ramming by providing all required grouting materials.
Wrapping of barbed wire on 11KV ST/PCC poles as anti-climbing device for a length of 0.9mtrs. Wire pitch/gap 13mm and fixing upper and lower end keeping lower end at a hieght of 2.75 mtr from the ground complete, including providing & fixing of lower end & upper end clamps made of M.S. Flat 40X5mm complete with nuts & bolts and all other required material and T&P.
Fabrication of Guarding Angle X Arm & other requisites material for guarding by drawing 02Nos G.I Wire and making loop at suitable distance as per RESPO drawing/Norms by providing holding clamps, 02Nos. Eye bolts made of M.S. round size 12mm dia-100mm long & Cross Arm clamps made of M.S. Flat of size 50X6mm and bolts as per norms of RESPO Norms.
Laying , Stringing and final sagging of ACSR Weasel Conductor after binding from Insulator, as per RESPO/Drawing Norms.
Laying , Stringing and final sagging of ACSR Rabbit Conductor after binding from Insulator, as per RESPO/Drawing Norms.
Laying , Stringing and final sagging of ACSR Dog Conductor after binding from Insulator, as per RESPO/Drawing Norms.
Providing & Fixing of G.I. pipe 6"dia Class-B over 11KV &33kv 3X70 and 3x120Sq.mm, 3x185 sq mm. &3x300 sq.mm. XLPE cable before mounting the cable at double pole. The work includes fitting of clamps, sealing of top and bottom of pipe and one end of pipe is to be burried under earth about 500mm earch including mounting and clamping the cable on double pole structure and making connection with overhead line at both ends.
Construction of T/F plinth suitable for 250 KVA & 400 KVA T/F (size of 2 x 2 x 1.5 mt) as per drawing, cc work in 0.5 meter foundation in ratio 1:4:8 (Cement, Sand & Brick ballast). Ist class brick work in side walls cc ratio of 1:4 (cement & fine sand). 12mm thick plaster in ratio 1:4 (cement & fine sand). The RCC work on top of plinth in ratio 1:2:4 after duly filling of brick ballast inside the plinth alongwith concealing of 02 No. Channel (length 2 meter long in the size 125x65 mm) & remaining the same, including cost of all material & labour.
Erection & Fixing of 11KV. Fuse set on ST Pole 11mtr long, by providing all required materials, including cost of 11KV Fuse set.
Erection & Fixing of 11KV. TPMO set on ST Pole 11mtr long, by providing all required materials, including cost of 11KV TPMO Set.
Providing fixing and fabrication Erection, Grouting & Painting of Wiremesh fencing on (MS angle 50x50x6 mm. & wiremesh 10 SWG Including civil welt 2x4x3 mtr. (size Hight x Length x Width) around the T/F plinth & LT tailless unit & 1 No.gate with locking arrangement including cost of all material and labour as per RESPO/drawing/Norms/as per site requirment.
Providing & Fixing of Danger Board, including fixing of all accessories by providing all required materials (like suitable clamps, nuts & bolts etc.) as per RESPO/Drawing Norms.
Providing & Fixing of Number Plate alongwith all required accessories (like suitable clamps, nuts & bolts etc.) as per RESPO/Drawing Norms.
Dismantling & Removal of old existing Meter Cubical/ CTPT
Dismantling & Removal of old existing STP/PCC pole after digging of pit and opening of all accessories.
Removal of old & used ACSR Conductor and opening from insulator and bundling of the same.
Dismantling & Removal of old & used 25/63KVA T/F and opening of all accessories.
Carriage of old & used STP/PCC from site of work to Electricity store center, Meerut with loading and unloading at both ends on Kachha Packka road. within 50 KM.
Carriage of old & used ACSR Conductor from site of work to Electricity center, Meerut with loading and unloading at both ends on Kachha Packka road.within 50 KM.
Carriage of old & used Meter Cubical/ CTPT from site of work toElectricity store center with loading and unloading at both ends on Kachha Packka road within 50 KM.
Providing & Fixing Chemical earthing of Transformers Equipment the ground surface where it will be bolted to the M.S. earth strip for connection the earth strip will be welded to the earthing and neutral support, as per RESPO/Norms.
Jumpering work properly as per RESPO/Norms.
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 4.55 MB
TD26F.pdf
Tender Documents • 0.90 MB
BOQ_2017137.xls
BOQ • 0.31 MB
Download all tender documents and submit your bid