| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.1 LAccepted-AOC 503 LAJPAT NAGAR ALWAR RAJ 301001 | ALWAR | RAJASTHAN | 301001 | L1 | Accepted-AOC AOC | |
| 2 | L2₹24.4 L+₹1.0 L (4.33%)Rejected-Finance PLOT NO 14 SHIV COLONY KATI GHATI RAJGARH ROAD ALWER RAJ | ALWAR | ALWAR | RAJASTHAN | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹26.0 L+₹2.6 L (11.3%)Rejected-Finance A 46 ARYA NAGAR ALWAR RAJ 301001 | ALWAR | RAJASTHAN | 301001 | L3 | Rejected-Finance Being L3 | |
| 4 | L4₹29.1 L+₹5.7 L (24.2%)Rejected-Finance WZ 576 577 NANGAL RAYA NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | L4 | Rejected-Finance Being L4 | |
| 5 | L5₹30.0 L+₹6.6 L (28.1%)Rejected-Finance | L5 | Rejected-Finance Being L5 |
Tender Value
₹29.5 L
EMD Value
₹59,000
Closing Date
31 Jan 2023, 6:00 pmClosed
GE Alwar
GE Alwar
REPAIR/MAINTENANCE OF INTERNAL ELECTRIFICATION AND MISC ITEMS IN OTM/MD ACCN IN CITY AREA UNDER GE ALWAR
2023_MES_572642_2
8090/E8
Open Tender
Electrical and Maintenance Works
Item Rate
240 days
Alwar
As per NIT
3 documents required · 3 mandatory
₹500
GE Alwar
₹59,000
Yes
16 Feb 2023
19 Jan 2023
2 Feb 2023
19 Jan 2023
31 Jan 2023
24 Jan 2023
19 Jan 2023 - 23 Jan 2023
Amount
Taking down carefully, copper / aluminium unserviceable /perished point wiring any type for light/ fan/ socket or power complete including fittings such as switches, ceiling roses, pendant holders, lamp holders, bracket holders, regulators sockets, light fittings etc, and making good to disturbed surfaces of wall/floor/ceiling etc, complete, all as specified and directed.
M&L for point wiring for one light point controlled by one, one way switch with 1.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade including 1.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade as continuous earth wire in green colour to common earth and connected to earth dolly laid/drawn into and including PVC casing & caping with accessories fixed on surface of walls/ceiling by means of PVC sleeves/dash fasteners with cadmium plated screws, all as per IS and including wooden boxes terminal boxes in wall for mounting fittings like switches, sockets, regulators etc with and including 3mm thick phenolic laminated sheet top cover complete all as specified & directed.
All as per description of serial item No 2.00 above but for One light point controlled by one, one way switch.
All as per description of serial item No. 2.00 above but for one fan point controlled by one switch and regulator complete all as specified and directed.
All as per description of serial item No. 2.00 above but for one exhaust fan point controlled by one switch complete all as specified and directed.
All as per description of serial item No 2.00 above but for one bell/buzzer point controlled by one bell push.
All as per description of serial item No 2.00 above but for one light point controlled by two, two way switch.
All as per description of serial item No 2.00 here-in-before but for one 3 pin socket outlet 5/6 Amps controlled by one switch, 5 Amp on same board.
All as per description of serial item No 2.00 here-in-before but for one 3 pin socket outlet 5/6 Amps controlled by one switch, 5 Amp independent board.
All as per description of serial item No 2.00 here-in-before but for one 3 pin socket outlet 15/16 Amps switch on independent boardwith 2.50 Sqmm two single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade including 1.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade as continuous earth wire in green colour.
All as per serial item No. 2.00 here-in-before but for one 3 pin 15/16 Amps socket outlet controlled by one 15/16 Amps switch on independent board with 4 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade including 2.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade as continuous earth wire in green colour.
S&F switch piano, flush type, single pole, one way, 5/6 Amp, 230 Volts complete all as specified & as directed.
S&F switch piano fulsh type, single pole, two way 5 Amps 230 Volts complete all as specified & as directed.
S&F switch piano, flush type, single pole, one way, 15 Amp, 230 Volts complete all as specified & as directed.
S&F socket outlet, 3 pin (with 2 pin outlet also), 5/6 Amp, flush type, 240 Volts complete all as specified & as directed.
S&F socket outlet, 2 in 1, 3 pin, 5 and 15 Amp, flush type, 240 Volts complete all as specified & as directed.
S&F bell push flush type 5 Amps 240 Volt complete all as specified & as directed.
S&F Electric bell Ding dong music type, AC 230 volts single pole complete all as specified & as directed.
S&F lamp holder, angular PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and directed.
S&F ceiling rose surface Bakelite 65x50mm two or three terminals.
S&F new fan regulators electronic step up type socket size and connecting up, ISI marked flush type, 240 Volts complete all as specified and directed.
S&F switch piano flush type, single pole, one way, 5/6 Amp, 230 Volts moduler type complete all as specified and directed.
S&F switch piano flush type, single pole, one way, 15/16 Amp, 230 Volts moduler type complete all as specified and directed.
S&F socket outlet for 2/3 pin, 6 Amp, modular type 240 Volt complete all as specified and directed.
S&F socket outlet for 2 in 1, 3 pin, 6/16 Amp, modular type 240 Volt complete all as specified and directed.
S&F PVC white cover plate with frame 2 Module complete all as specified & as directed.
S&F PVC white cover plate with frame 3 Module complete all as specified & as directed.
S&F PVC white cover plate with frame 4 Module complete all as specified & as directed.
S&F PVC white cover plate with frame 6 Module complete all as specified & as directed.
S&F PVC white cover plate with frame 8 Module complete all as specified & as directed.
S&F Modular fan step regulator, 120 W, 2 module and connecting up, ISI marked, 250 Volts.
S&F decorative ultra slim liner LED lighting fixture with extended poly carbonate environmental friendly, energy efficient suitable for 20W with LED tube of model E-LITE LED pride plus and connecting up complete all as specified and directed. Make : Havells Cat part No LHEXBLP7PN1W020 or equivalent of Philips/Crompton Greaves/ Bajaj/ Syska
S&F decorative ultra slim square box profile liner LED lighting fixture with extended polycarbonate, environmental friendly, energy efficient suitable for 9 Watt with LED tube of model E-LITE LED Pride and connecting up with and including white coloured flat/round twin core, PVC insulated, sheathed copper conductore cable of required size and length from ceiling rose to fitting complete, all as specified & directed. Make : Havells Cat Part No LHEXBLP7IN1W009 or equivalent of Syska / Crompton Greaves as approved by GE
Fixing only any type LED/FTL tube light fittings, any type, any make, any size on wall/ceiling including plastic/wooden block and connecting up with flexible twin core copper cable of size 23/0.0076 complete with all standard fittings such as bipin holders. starter holders connector block etc and prewired up to main connection. Note :- Tube Light Fitting and Tube Rod retrieved from taking down of point wiring and light fitting under respective item shall be used.
S&F sheet metal enclosures double door type, suitable for fixing MCB, TPN with 200 amps rated bus bar, 4 way 415 Volts complete all as specified & as directed.
S&F sheet metal enclosures double door type, suitable for fixing MCCB 125 Amps, TPN with 200 Amps rated bus bar, vertical DB 8 way TPN including incoming MCCB 125 Amps. 415 Volts complete all as specified & as directed.
S&F sheet metal enclosures double door type, suitable for fixing MCBs, SPN with 200 Amps rated bus bar, 8 way, 240 volts complete all as specified & as directed.
S&F sheet metal enclosures, double door type, suitable for fixing MCBs, SPN with 200 Amps rated bus bar, 4 way, 240 volts complete all as specified & as directed.
S&F sheet metal enclosures, double door type, suitable for fixing MCBs, SPN with 200 Amps rated bus bar, 2 way, 230 volts complete all as specified & as directed.
S&F MCB 32 Amps, single pole & neutral, 240 volts complete all as specified & as directed.
S&F MCB 5 to 32 Amps, single pole & neutral, 240 Volts complete all as specified & as directed.
S&F MCB 32 to 63 Amps, triple pole & neutral, 415 volts complete all as specified & as directed.
S&F 2nd class hard wood rectangular block open recessed of size 45cm x 30cm x 5cm depth with 3mm thick phenolic laminated sheet top cover fixed with suitable steel screws & PVC rawl plug (4 Nos), for DB complete all as specified & directed.
S&F 2nd class hard wood rectangular block open recessed of size 30cm x 25cm x 5cm depth with 3mm thick phenolic laminated sheet top cover fixed with suitable steel screws & PVC rawl plug (4 Nos), for DB complete all as specified & directed.
Supply, installing and testing out door wheather proof bus bar chamber of size 60cm x 40cm x 40cm made out of 3.15mm MS sheet having one side openable hinged door shutter with locking arrangement &provn of two Nos 60cm long 40mm x 40mm x 6mm angle iron legs welded and 4 Nos Aluminium bus bar of 200 Amp rating and incoming MCCB 63 Amps adjustable thermal magnetic release type complete errected on ground with necessary PCC 1;3;6 type C-2 foundation complete bus bar chamber painted with two coats of approved enamel paints over one coat of primer including making cable connection with necessary gland ,lugs/thimbles complete all as specified and directed.
S&F sub main wiring on and including PVC conduit, 1100 Volts grade cable, PVC insulated copper conductor and over all PVC unsheathed for sub main wiring multistranded conductor of 6 Sqmm single core cable and earth wire of 6 Sqmm unsheathed copper conductor complete. (Two run of cable with one run of earth wire should measured as one length) including taking down existing unserviceable sub main wiring.
S&F sub main wiring on and including passing through PVC conduit pipe 1100 Volts grade with PVC flexible cable copper conductor unsheathed multistranded single core of size 4 sqmm and continuous earth with PVC flexible cable copper conductor unsheathed multistranded single core of size 4 sqmm of green colour confirming to IS 694/1990 including taking down existing unserviceable sub main wiring. (Note: Two runs of cable with one run of earth wire and one run of PVC conduit should measured as one length).
S&F sub main wiring on and including passing through PVC conduit pipe 1100 Volts grade with PVC flexible cable copper conductor unsheathed multistranded single core of size 6sqmm and continuous earth with PVC flexible cable copper conductor unsheathed multistranded single core of size 6 sqmm of green colour confirming to IS 694/1990 including taking down existing unserviceable sub main wiring. (Note: four runs of cable with two run of earth wire and one run of PVC conduit should measured as one length).
S&F sub main wiring on and including passing through PVC conduit pipe 1100 Volts grade with PVC flexible cable copper conductor unsheathed multistranded single core of size 10sqmm and continuous earth with PVC flexible cable copper conductor unsheathed multistranded single core of size 6 sqmm of green colour confirming to IS 694/1990 including taking down existing unserviceable sub main wiring. (Note: four runs of cable with two run of earth wire and one run of PVC conduit should measured as one length).
S&F Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amp, 240 Volt, all as specified.
S&F LED Driver 18 Watt for LED lights input voltage AC 90-265 V,DC output Voltage 42-62 V & including taking down old U/S LED driver. Make : Havells, CG, Phillips or equivalent.
S&F CFL 36 watt 4 pin type for PL-L light & including taking down old U/S CFL pin type. Make : Havells, CG, Phillips or equivalent.
S&F Ecoclick starter for FTL light fitting 18 Watt ,working in 110V-130V all as specified and directed & including taking down old U/S starter.
S&F LED Driver for tube light fixture 18 Watt suitable for existing light & including taking down old U/S LED driver Make : Havells,Syska,Phillips
S&F LED Driver for tube light fixture 9 Watt suitable for existing light & including taking down old U/S LED driver Make : Havells, Syska, Phillips
Taking down existing bedside light and S&F existing Bedside decorative wall mounting light SS finish with opal glass diffuser suitable for 1 x 8 watt TU retrofit CFL with & including 1 x 8 watt CFL, E14 TU, prewired and connecting up ,complete all as specified & directed. Make- Havells Cat part No LHJCO 2108499 or equivalent of Bajaj/ Philips/ CG
S&F recess 34/36 watt ultra slim edge 2x2 feet lit panel in aluminium casing recess mounted square fixture in white finish suitable for low ceiling height ,3in1,3K,4K,6K with &including LED prewired & connecting up &dismentling of old U/S recess mounted light. Make-Havells cat part No-LHEBLOPNUZ1W018 or equivalent make.
S&F Surface LED luminaires 1x20 watt ,230 volts 50Hz, new E-LITE LED Triyca batten, A color changing LED batten with options of 3000K,4000K &6500K,all in one fixture all as specified and directed including taking down old existing U/S surface LED complete all as specified & directed. Make : Havells cat part No LHEXBYPNIN1W020 or equivalent make.
S&F Surface decorative wall/ceiling mounted LED 12 watt fixture with electronic driver suitable for indoor applications,all as specified and directed. Make-Havells cat part No -LHEOFJP7CUZ1W012 or equivalent of Phillips /CG/Bajaj
S&F Recess mounted compact vertical round shaped downlighter with removable driver suitable low ceiling height, LED 5 watt , 6000K all as specified & directed. Make :- Havells Cat Part No - HEEPP5IN1W005 or euivalent of Bajaj/Philips /CG.
S&F Recess mounted compact vertical round shaped downlighter with removable driver suitable low ceiling height, LED 12 watt ,6000K all as specified & directed. Make ;- Havells Cat Part No-LHEEPP5IN1W012 or equivalent of Bajaj/Philips /CG.
S&F Surface mounted square shaped LED downlighter 12 W, 4000K with drable housing with alum. Heat sink with diffuser to give glare free light removable driver all as specified and directed. Havells Cat Part No-LHEAASP6UL1W012 or equivalent of Bajaj/Philips /CG.
S&F MCCB 4 Pole ,100 Amps rating rupturing capacity 25 KA ,415 volts grade AC,50 HZ magnetic fixed type and making connections including disconnecting & taking down old U/S ,MCCB complete ,all as specified and directed.
S&F MCCB 4 Pole ,63 Amps rating rupturing capacity 16 KA ,415 volts grade AC,50 HZ magnetic fixed type and making connections including disconnecting & taking down old U/S, MCCB complete ,all as specified and directed.
S&F Sheet metal enclousure double door type, suitable for fixing MCCB 63 Amps,TPN with 200 Amps rated bus bar, vertical DB 4 way TPN including incomoing MCCB 63 Amps, 415 Volts complete & taking down old U/S MCCB all as specified & directed.
Disconnecting electric connections and taking down existing electric meter from wooden board ,and S&F new wooden board of size and Reconnecting ,Refixing existing meter to the location as specified & directed.
S&F Heavy duty PVC pipe 50 mm dia with accessories & fixing clips,screws, rawl plugs complete all as specified & directed.
S&F PVC Channel 100 mm wide slotted clip on type with PVC caping cover for wiring /cabling in bunches complete all as specified & directed.
S&F on load Changeover switch front operated 100 Amp, AC, 3 Phase, 4 Pole 415 volts, including taking down old U/S changeover switch. Make : Crompton Greaves / Havells/HPL
S&F on load Changeover switch front operated 250 Amp ,AC ,3 Phase 4-pole 415 volts, including taking down old U/S changeover switch. Make : Crompton Greaves / Havells/HPL
S&F in repair switch piano, flush type, single pole, one way, 5/6 Amp, 230 Volts complete all as specified & as directed.
S&F switch piano fulsh type, single pole, two way 5 Amps 230 Volts complete all as specified & as directed.
S&F switch piano, flush type, single pole, one way, 15 Amp, 230 Volts complete all as specified & as directed.
S&F switch bell push type single pole ,5 Amp 230 volts ,fixed in repairs all including taking down old UNSV switch any type and connecting up complete all as specified & directed.
S&F socket outlet, 3 pin (with 2 pin outlet also), 5/6 Amp, flush type, 240 Volts complete all as specified & as directed.
S&F socket outlet, 2 in 1, 3 pin, 5 and 15 Amp, flush type, 240 Volts complete all as specified & as directed.
S&F electric bell Ding Dong type AC,230 Volts ,single pole, fixed in repairs all including taking down old UNSV bell any type and connecting up.
S&F angular/batten lamp holder, polycarbonate body with back plate suitable for batten fitting ,fixed in repairs all including taking down old UNSV holder any type and connecting up complet all as specified & directed.
S&F electronic, stepped up & socket type fan regulator ,0-4 step of cap. 100 watt ,230 volts AC,fixed in repairs all including taking down old UNSV regulator any type and connecting up complete all as specified & directed.
S &F ceiling rose surface bakelite 65x50mm ,two or three terminals ,fixed in repairs all including taking down old UNSV switch any type and connecting up complete all as specified & directed.
S&F electronic ballast ,230 volts 36/40 watt suitable for 40 watt FTL fitting complete ,fixed in repairs all including taking down old UNSV choke any type & connecting up.
S&F bipin holder rotary type suitable for 36/40 watt FTL fitting ,fixed in repairs all including taking down old UNSV Bipin holder any type and connecting up.,
S&F MCB 32 to 63 Amps ,SPN, 230 Volts fixed in repair all including taking down old UNSV MCB any type and connecting up.
S&F , MCB 6 to 32 Amps ,SP,230 Volts fixed in repair all including taking down old UNSV MCB any type and connecting up.
S&F ,MCB 32 to 63 Amps ,TPN,415 Volts fixed in repair all including taking down old UNSV MCB any type and connecting up.
M&L for earthing complete with galvanized steel earth plate electrode 60cmx60cmx6.30mm thick burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of plate not less than 1.5 m deep below normal ground level and connected to and including galvanized iron earth wire 4 mm dia by means of GI nuts, bolts, check nuts, washers thimbles, etc as shown in electrical plate No 3 of SSR Part-I and connection to main switch board/Test point/panel/ equipment and testing on completion including excavation and earth work in any type of soil, returning filling in, and removal of surplus spoil to a distance not exc 50 metre,charcoal and salt in alternate layer 15 cm thick all around the earth plate electrode, MS funnel with wire mesh, GI pipe medium grade 20 mm bore for watering and 15 mm bore 3.00 metre long GI pipe light grade for earth wire protection fixed with poles with two clamps, made from MS flat 25 mmx3mm, bolts, nuts and washers, PCC chamber (1:3:6) type C1, 40mm thick precast RCC cover 1:2:4 type B1 shall be provided on CI frame etc complete all as specified & directed & including taking down earth plate.
S&F sealed lead acid battery Cap. 65 AH 12 volt type taking down old U/S battery all as specified and directed. Make -Exide model Powersafe Plus No EP 65-12 &
Servicing of UPS 10 KVA by blower in existing location, open connection checking the IC and including replacement of U/S spare parts if any Mass Pad, control card, power card etc complete all as specified and directed by Engineer-in-Charge
Supply, laying, jointing and testing XLPE insulated armoured heavy duty LT under ground electric cable with aluminium stranded conductor 1100 Volt grade cross sectional area 16sqmm 2 core laid in trenches/ducts, through pipe, under floors or roads/ along poles etc complete all as specified. Note :- Sand cushioning, cable protection, GI protection pipe, clamps, jointing kits and excavation & earth work shall be measured & paid for separately.
Supply, laying, jointing and testing XLPE insulated armoured heavy duty LT under ground electric cable with aluminium stranded conductor 1100 Volt grade cross sectional area 10 sqmm 2 core laid in trenches/ducts, through pipe, under floors or roads/ along poles etc complete all as specified. Note :- Sand cushioning, cable protection, GI protection pipe, clamps, jointing kits and excavation & earth work shall be measured & paid for separately.
S&F LED Bulb energy saving 10/11 W complete all as specified and directed Make :- Havells/Crompton/Syska
Excavating in trenches not exc 1.5 metre wide and not exc 1.5 metre in depth for foundation or for shafts, walls, manholes etc not exc 10 Sqm on plan and getting out in soft/loose soil.
Returning, filling in, including spreading, leveling watering and well ramming in layers not exc 25 cm thick in soft/loose soil.
Removal of excavated soil/ material to a distance not exc 50 metre and depositing where directed at a level not exc 1.50 metre above the starting point complete all as specified.
M&L for brick work with FLY ASH BRICKS {As per IS-13757 (1993) burnt clay fly ash building bricks}, (OLD SIZE BRICKS) with width equal to the length of the brick laid dry & flat abutted with each other with gap between adjacent bricks not exc 10 mm over UG cable for protection including taking down old unserviceable bricks complete all as specified & directed.
M&L for dry sand cushioning to PVC under ground cable with screened and washed sand and punning to provide a required cover complete all as specified and directed. Note :- Thickness after punning shall be considered for payment.
M&L galvanised steel water tubing light grade of 40mm bore with & including all fittings complete laid in trenches. Note :- Excavation & earthwork shall be measured & paid for separately.
M/s Yash Electrical and Maintenance
M/s ASK Enterprises
Shiv Enterprises
A B K Enterprises
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .