Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹9.5 LAccepted-AOC B WING 601 602 DELPHI BUILDING CENTRAL AVENUE HIRANANDANI BUSINESS PARK POWAI MUMBAI MAHARASHTRA 400076 | MUMBAI SUBURBAN | MAHARASHTRA | 400076 | 1 | Accepted-AOC L1 | |
| 2 | 1₹14.2 LAccepted-AOC 204 205 KAILASH TOWER TONK ROAD JAIPUR RAJASTHAN | JAIPUR | JAIPUR | RAJASTHAN | 302015 | 1 | Accepted-AOC L1 | |
| 3 | 1₹39.9 LAccepted-AOC 53 54 56 AND 57 HADPSAR IND ESTATE PUNE MAHARASHTRA 411013 | PUNE | PUNE | MAHARASHTRA | 411013 | 1 | Accepted-AOC L1 | |
| 4 | 2₹38.8 LRejected-Finance 2ND FLOOR 4 329A OLD MAHABALIPURAM ROAD CHENNAI TAMIL NADU CHENNAI TAMIL NADU 600041 | CHENNAI | TAMIL NADU | 600041 | 2 | Rejected-Finance L1 | |
| 5 | 3₹48.6 LRejected-Finance 7TH FLOOR 7B GODREJ ONE BUILDING PIROJSHANAGAR EASTERN EXPRESS HIGHWAY VIKHROLI E MUMBAI MAHARASHTRA 400079 | MUMBAI SUBURBAN | MAHARASHTRA | 400079 | 3 | Rejected-Finance L1 |
Tender Value
Refer Docs
Closing Date
18 Aug 2020, 12:30 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Mr.Puneet Khanna (Head-Supply Chain Management)
Worley India Private Limited, New Energy House,RamakrishnaMandir Road, Kondivita, Andheri (East), Mumbai- 400 059, India
FIELD TRANSMITTERS
2020_REFHQ_120764_1
44AC7500-00-ER-64-0020
Limited
Instrumentation-Goods
Supply
150 days
IOCL PANIPAT, HARYANA INDIA
NOT APPLICABLE
3 documents required · 3 mandatory
Exempted
3 May 2021
21 Jul 2020
19 Aug 2020
21 Jul 2020
18 Aug 2020
28 Jul 2020
120 days
Field Transmitters – Pressure (Total Quantity: 110 Nos.
Pressure Transmitter Sensor Material : Hastelloy C Process Connection: ½” NPT Calibration Range: 0 to 10 kg/cm²-g With Kidney Flange Adapter (Refer Datasheet Doc. No. 44AC7500-01-J.04A-0020) Mandatory Spare: 1 no. of complete Transmitter assembly as per above details.
Pressure Transmitter Sensor Material : Hastelloy C Process Connection: ½” NPT Calibration Range: 0 to 6 kg/cm²-g Special Requirement: IBR With Kidney Flange Adapter (Refer Datasheet Doc. No. 44AC7500-01-J.04A-0020) Mandatory Spare: 1 no. of complete Transmitter assembly as per above details.
Pressure Transmitter Sensor Material : Hastelloy C Process Connection: ½” NPT Calibration Range: 0 to 20 kg/cm²-g With Kidney Flange Adapter (Refer Datasheet Doc. No. 44AC7500-01-J.04A-0020) Mandatory Spare: 1 no. of complete Transmitter assembly asper above details.
Pressure Transmitter Sensor Material : Hastelloy C Process Connection: ½” NPT Calibration Range: 0 to 25 kg/cm²-g With Kidney Flange Adapter (Refer Datasheet Doc. No. 44AC7500-01-J.04A-0020) Mandatory Spare: 1 no. of complete Transmitter assembly as per above details.
Pressure Transmitter Sensor Material : Hastelloy C Process Connection: ½” NPT Calibration Range: -1 to 1 kg/cm²-g With Kidney Flange Adapter (Refer Datasheet Doc. No. 44AC7500-01-J.04A-0020) Mandatory Spare: 1 no. of complete Transmitter assembly as per above details.
Pressure Transmitter Sensor Material : Hastelloy C Process Connection: ½” NPT Calibration Range: 0 to 6 kg/cm²-g With Kidney Flange Adapter (Refer Datasheet Doc. No. 44AC7500-01-J.04A-0020) Mandatory Spare: 1 no. of complete Transmitter assembly as per above details.
Pressure Transmitter Sensor Material : Hastelloy C Process Connection: ½” NPT Calibration Range: -1 to 10 kg/cm²-g With Kidney Flange Adapter (Refer Datasheet Doc. No. 44AC7500-01-J.04A-0020) Mandatory Spare: 1 no. of complete Transmitter assembly as per above details.
Pressure Transmitter Sensor Material : Hastelloy C Process Connection: ½” NPT Calibration Range: -1 to 9 kg/cm²-g With Kidney Flange Adapter (Refer Datasheet Doc. No. 44AC7500-01-J.04A-0020) Mandatory Spare: 1 no. of complete Transmitter assembly as per above details.
Pressure Transmitter Sensor Material : Hastelloy C Process Connection: ½” NPT Calibration Range: -1 to 6 kg/cm²-g With Kidney Flange Adapter (Refer Datasheet Doc. No. 44AC7500-01-J.04A-0020) Mandatory Spare: 1 no. of complete Transmitter assembly as per above details.
Pressure Transmitter Sensor Material : SS 316 Process Connection: ½” NPT Calibration Range: 0 to 10 kg/cm²-g With Kidney Flange Adapter (Refer Datasheet Doc. No. 44AC7500-01-J.04A-0020) Mandatory Spare: 1 no. of complete Transmitter assembly as per above details.
Pressure Transmitter with Chemical Seal Sensor Material : SS 316 Upper Housing Material: SS 316L Chemical Seal Material: Hastelloy C Lower Housing Material: SS 316L Calibration Range: 0 to 10 kg/cm²-g Process Connection: 300#, Saddle type for 6” pipe (Refer Datasheet Doc. No. 44AC7500-01-J.04A-0020) Mandatory Spare: 1 no. of complete Transmitter assembly as per above details.
Pressure Transmitter with Chemical Seal Sensor Material : SS 316 Upper Housing Material: SS 316L Chemical Seal Material: Hastelloy C Lower Housing Material: SS 316L Calibration Range: 0 to 10 kg/cm²-g Process Connection: 300#, Saddle type for 4” pipe (Refer Datasheet Doc. No. 44AC7500-01-J.04A-0020) Mandatory Spare: 1 no. of complete Transmitter assembly as per above details.
Pressure Transmitter with Chemical Seal Sensor Material : SS 316 Upper Housing Material: SS 316L Chemical Seal Material: Hastelloy C Lower Housing Material: SS 316L Calibration Range: 0 to 10 kg/cm²-g Process Connection: 300#, Saddle type for 14” pipe (Refer Datasheet Doc. No. 44AC7500-01-J.04A-0020) Mandatory Spare: 1 no. of complete Transmitter assembly as per above details.
Pressure Transmitter with Chemical Seal Sensor Material : SS 316 Upper Housing Material: SS 316L Chemical Seal Material: Hastelloy C Lower Housing Material: SS 316L Calibration Range: 0 to 10 kg/cm²-g Process Connection: 300#, Saddle type for 8” pipe (Refer Datasheet Doc. No. 44AC7500-01-J.04A-0020) Mandatory Spare: 1 no. of complete Transmitter assembly as per above details.
Pressure Transmitter with Chemical Seal Sensor Material : SS 316 Upper Housing Material: SS 316L Chemical Seal Material: Hastelloy C Lower Housing Material: SS 316L Calibration Range: 0 to 18 kg/cm²-g Process Connection: 300#, Saddle type for 1.5” pipe. Saddle flange shall be provided with spool arrangement withweld-able ends. (Refer Datasheet Doc. No. 44AC7500-01-J.04A-0020) Mandatory Spare: 1 no. of complete Transmitter assembly as per above details.
Pressure Transmitter with Chemical Seal Sensor Material : SS 316 Upper Housing Material: SS 316L Chemical Seal Material: Hastelloy C Lower Housing Material: SS 316L Calibration Range: 0 to 14 kg/cm²-g Process Connection: Saddle type for 10” pipe (Refer Datasheet Doc. No. 44AC7500-01-J.04A-0020) Mandatory Spare: 1 no. of complete Transmitter assembly as per above details.
Pressure Transmitter Sensor Material : SS 316 Process Connection: ½” NPT Calibration Range: 0 to 10 kg/cm²-g With Kidney Flange Adapter (Refer Datasheet Doc. No. 44AC7500-02-J.04A-0020) Mandatory Spare: 1 no. of complete Transmitter assembly as per above details.
Pressure Transmitter Sensor Material : SS 316 Process Connection: ½” NPT Calibration Range: 0 to 50 kg/cm²-g With Kidney Flange Adapter (Refer Datasheet Doc. No. 44AC7500-02-J.04A-0020) Mandatory Spare: 1 no. of complete Transmitter assembly as per above details.
Pressure Transmitter Sensor Material : SS 316 Process Connection: ½” NPT Calibration Range: 0 to 40 kg/cm²-g Special Requirement: NACE Compliance With Kidney Flange Adapter (Refer Datasheet Doc. No. 44AC7500-02-J.04A-0020) Mandatory Spare: 1 no. of complete Transmitter assembly as per above details
Pressure Transmitter Sensor Material : SS 316 Process Connection: ½” NPT Calibration Range: 0 to 40 kg/cm²-g With Kidney Flange Adapter (Refer Datasheet Doc. No. 44AC7500-02-J.04A-0020) Mandatory Spare:
Pressure Transmitter Sensor Material : SS 316 Process Connection: ½” NPT Calibration Range: 0 to 1.5 kg/cm²-g With Kidney Flange Adapter (Refer Datasheet Doc. No. 44AC7500-02-J.04A-0020) Mandatory Spare: 1 no. of complete Transmitter assembly as per above details.
Pressure Transmitter Sensor Material : SS 316 Process Connection: ½” NPT Calibration Range: 0 to 30 kg/cm²-g With Kidney Flange Adapter (Refer Datasheet Doc. No. 44AC7500-02-J.04A-0020) Mandatory Spare: 1 no. of complete Transmitter assembly as per above details.
Pressure Transmitter Sensor Material : SS 316 Process Connection: ½” NPT Calibration Range: 0 to 5 kg/cm²-g With Kidney Flange Adapter (Refer Datasheet Doc. No. 44AC7500-02-J.04A-0020) Mandatory Spare: 1 no. of complete Transmitter assembly as per above details
Pressure Transmitter Sensor Material : SS 316 Process Connection: ½” NPT Calibration Range: 0 to 3 kg/cm²-g With Kidney Flange Adapter (Refer Datasheet Doc. No. 44AC7500-02-J.04A-0020) Mandatory Spare: 1 no. of complete Transmitter assembly as per above details.
Pressure Transmitter Sensor Material : SS 316 Process Connection: ½” NPT Calibration Range: 0 to 3.5 kg/cm²-g With Kidney Flange Adapter (Refer Datasheet Doc. No. 44AC7500-02-J.04A-0020) Mandatory Spare: 1 no. of complete Transmitter assembly as per above details.
Pressure Transmitter Sensor Material : SS 316 Process Connection: ½” NPT Calibration Range: 0 to 4 kg/cm²-g With Kidney Flange Adapter (Refer Datasheet Doc. No. 44AC7500-02-J.04A-0020) Mandatory Spare: 1 no. of complete Transmitter assembly as per above details.
Pressure Transmitter Sensor Material : SS 316 Process Connection: ½” NPT Calibration Range: -1 to 1 kg/cm²-g With Kidney Flange Adapter (Refer Datasheet Doc. No. 44AC7500-02-J.04A-0020) Mandatory Spare: 1 no. of complete Transmitter assembly as per above details.
Pressure Transmitter Sensor Material : SS 316 Process Connection: ½” NPT Calibration Range: 0 to 25 kg/cm²-g With Kidney Flange Adapter (Refer Datasheet Doc. No. 44AC7500-02-J.04A-0020) Mandatory Spare: 1 no. of complete Transmitter assembly as per above details.
Pressure Transmitter Sensor Material : SS 316 Process Connection: ½” NPT Calibration Range: 0 to 20 kg/cm²-g With Kidney Flange Adapter (Refer Datasheet Doc. No. 44AC7500-02-J.04A-0020) Mandatory Spare: 1 no. of complete Transmitter assembly as per above details.
Field Transmitter - Temperature (Total Quantity: 140 Nos.)
Temperature Transmitter (Refer Datasheet Doc. No. 44AC7500-01-J.04A-0049) Mandatory Spare: 1 no. of complete Transmitter assembly as per above details.
Temperature Transmitter (Refer Datasheet Doc. No. 44AC7500-01-J.04A-0049) Mandatory Spare: 1 no. of complete Transmitter assembly as per above details.
Temperature Transmitter (Refer Datasheet Doc. No. 44AC7500-01-J.04A-0049) Mandatory Spare: 1 no. of complete Transmitter assembly as per above details.
Temperature Transmitter (Refer Datasheet Doc. No. 44AC7500-01-J.04A-0049) Mandatory Spare: 1 no. of complete Transmitter assembly as per above details.
Temperature Transmitter (Refer Datasheet Doc. No. 44AC7500-01-J.04A-0049) Mandatory Spare: 1 no. of complete Transmitter assembly as per above details.
Temperature Transmitter (Refer Datasheet Doc. No. 44AC7500-02-J.04A-0049) Mandatory Spare: 1 no. of complete Transmitter assembly as per above details
Description of Work / Item(s)
RECOMMENDED SPARES FOR TWO YEARS O&M – FOR SR NO 1.01 OF BOQ1
RECOMMENDED SPARES FOR TWO YEARS O&M – FOR SR NO 1.02 OF BOQ1
RECOMMENDED SPARES FOR TWO YEARS O&M – FOR SR NO 1.03 OF BOQ1
RECOMMENDED SPARES FOR TWO YEARS O&M – FOR SR NO 1.04 OF BOQ1
RECOMMENDED SPARES FOR TWO YEARS O&M – FOR SR NO 1.05 OF BOQ1
RECOMMENDED SPARES FOR TWO YEARS O&M – FOR SR NO 1.06 OF BOQ1
RECOMMENDED SPARES FOR TWO YEARS O&M – FOR SR NO 1.07 OF BOQ1
RECOMMENDED SPARES FOR TWO YEARS O&M – FOR SR NO 1.08 OF BOQ1
RECOMMENDED SPARES FOR TWO YEARS O&M – FOR SR NO 1.09 OF BOQ1
RECOMMENDED SPARES FOR TWO YEARS O&M – FOR SR NO 1.10 OF BOQ1
RECOMMENDED SPARES FOR TWO YEARS O&M – FOR SR NO 1.11 OF BOQ1
RECOMMENDED SPARES FOR TWO YEARS O&M – FOR SR NO 1.12 OF BOQ1
RECOMMENDED SPARES FOR TWO YEARS O&M – FOR SR NO 1.13 OF BOQ1
RECOMMENDED SPARES FOR TWO YEARS O&M – FOR SR NO 1.14 OF BOQ1
RECOMMENDED SPARES FOR TWO YEARS O&M – FOR SR NO 1.15 OF BOQ1
RECOMMENDED SPARES FOR TWO YEARS O&M – FOR SR NO 1.16 OF BOQ1
RECOMMENDED SPARES FOR TWO YEARS O&M – FOR SR NO 1.17 OF BOQ1
RECOMMENDED SPARES FOR TWO YEARS O&M – FOR SR NO 1.18 OF BOQ1
RECOMMENDED SPARES FOR TWO YEARS O&M – FOR SR NO 1.19 OF BOQ1
RECOMMENDED SPARES FOR TWO YEARS O&M – FOR SR NO 1.20 OF BOQ1
RECOMMENDED SPARES FOR TWO YEARS O&M – FOR SR NO 1.21 OF BOQ1
RECOMMENDED SPARES FOR TWO YEARS O&M – FOR SR NO 1.22 OF BOQ1
RECOMMENDED SPARES FOR TWO YEARS O&M – FOR SR NO 1.23 OF BOQ1
RECOMMENDED SPARES FOR TWO YEARS O&M – FOR SR NO 1.24 OF BOQ1
RECOMMENDED SPARES FOR TWO YEARS O&M – FOR SR NO 1.25 OF BOQ1
RECOMMENDED SPARES FOR TWO YEARS O&M – FOR SR NO 1.26 OF BOQ1
RECOMMENDED SPARES FOR TWO YEARS O&M – FOR SR NO 1.27 OF BOQ1
RECOMMENDED SPARES FOR TWO YEARS O&M – FOR SR NO 1.28 OF BOQ1
RECOMMENDED SPARES FOR TWO YEARS O&M – FOR SR NO 1.29 OF BOQ1
RECOMMENDED SPARES FOR TWO YEARS O&M – FOR SR NO 2.01 OF BOQ1
RECOMMENDED SPARES FOR TWO YEARS O&M – FOR SR NO 2.02 OF BOQ1
RECOMMENDED SPARES FOR TWO YEARS O&M – FOR SR NO 2.03 OF BOQ1
RECOMMENDED SPARES FOR TWO YEARS O&M – FOR SR NO 2.04 OF BOQ1
RECOMMENDED SPARES FOR TWO YEARS O&M – FOR SR NO 2.05 OF BOQ1
RECOMMENDED SPARES FOR TWO YEARS O&M – FOR SR NO 2.06 OF BOQ1
Fuji Electric India Pvt. Ltd.
Honeywell Automation India Limited.
Endress and Hauser india pvt ltd
Emerson Process Management
Endress and Hauser india pvt ltd
Honeywell Automation India Limited.
Emerson Process Management
Fuji Electric India Pvt. Ltd.
Endress and Hauser india pvt ltd
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .