Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.8 LAccepted-AOC 2 89 BIJOYGARH JADAVPUR KOLKATA 700032 | KOLKATA | KOLKATA | WEST BENGAL | 700032 | L1 | Accepted-AOC AOC Issued | |
| 2 | L2₹4.1 L+₹22,118 (5.77%)Rejected-Finance 3 C DR JAGABANDHU LANE KOLKATA 700012 | KOLKATA | KOLKATA | WEST BENGAL | 700012 | L2 | Rejected-Finance That the bid is not L1 | |
| 3 | L3₹4.1 L+₹26,955 (7.03%)Rejected-Finance 24C GOABAGAN LANE KOLKATA 700 006 | KOLKATA | KOLKATA | WEST BENGAL | 700006 | L3 | Rejected-Finance That the bid is not L1 |
Tender Value
Refer Docs
EMD Value
₹8,440
Closing Date
21 Mar 2024, 1:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Assistant Engineer, KMC Electrical Sub-Division
OFFICE OF THE ASISTANT ENGINEER Kolkata Medical College Electrical Sub-Division, P.W.Dte.Green Building, MCH Campus 88, College Street, Kolkata-700073.
Electrical renovation work at erstwhile Digital X Ray room for space enhancement at Dispensary under School of Tropical building, Kolkata. E.I and AC Work.
2024_WBPWD_676266_1
WBPWD/AE/KMCESD/NIQ-105/23-24
Open Tender
ELECTRICAL WORKS ORG
Item Rate
15 days
Kolkata
Please refer Tender documents.
5 documents required · 5 mandatory
₹8,440
6 Sept 2024
28 Feb 2024
27 Mar 2024
5 Mar 2024
21 Mar 2024
5 Mar 2024
Amount
Dismantling the existing E.I. work (Main Switch, HTPNDB, Panel, existing cable) by Co's own tools & tackles and take unnecessary items away from site by maintaining normalcy as far as possible as per direction of EIC .
Distribution wiring in 2 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Modular type switch (Brand approved by EIC) fixed on Modular GI switch board with top cover plate and 2 no. suitable size “Ph & N” copper bar & earthing attachment fixed on wall incl. mending good damages to original finish. (Avg Run - 9 Mtrs)
Supplying and fixing double door Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment as per GS( Make - Legrand ) a) 4 Way ( Up to 160 A ) (Make - Legrand - 607913)
Supplying and fixing 415 V Four Pole MCCB of Breaking capacity 25kA/35kA in existing Vertical DBs including necessary connection as per GS [ Make - Legrand ]. A) 160 A FP
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connections per GS [ Make -Legrand ] a) 63 TP
Supplying and fixing double door sheet steel (16SWG), powder coated cable end box for 4 way vertical enclosure with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish with nuts bolts etc incl. provision for earthing attachment
Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment a) 6 WAY (Enclosure - 607716)
Supplying and fixing 415 V MCB Isolator on din rail of existing DBs and necessary connection a) 63A FP
Supplying and fixing 240V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection a) 10 - 32A
Supplying and fixing double door sheet steel (16SWG), powder coated cable end box for TPN DB horizontal enclosure with IP-42/43 protection, on angle iron frame on wall & mendinggood the damages to original finish with nuts bolts etc incl. provision for earthing attachment a) 6WAY
Supplying and fixing double-door 12 way SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. (Make - 607712)
Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection a) 40A DP MCB Isolator
Supplying and fixing 240 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection a) 6 - 32A
S & Fixing 250 V 50 HZ, 18" (450 mm) high flo (air delivery-- 4500 CFM, RPM-- 1370) non-oscillating type fully metal body Wall Bracket fan with inbuilt regulator, double ball bearing, intergally cast LM6 impeller (Make - EPC Tempest) .
Supply of cables :--- Supplying and Delivery of following sizes Al. armoured PVC/XLPE cable (Havells/gloster/KEI) as mentioned below : a. 4 core 50 sqmm ( PANEL TO VTPN)
b. 4 core 35 sqmm (from VTPNDB to POWERDB)
Laying of cables :--- Laying of 4 core 50 Sqmm Al. armoured PVC/XLPE cable (Havells/Glostar/KEI) with 2X10 SWG GI wire making hole etc. as necy., mending good damages and painting as mentioned below a. on wall by clamp
Laying of 4 core 35 Sqmm Al. armoured PVC/XLPE cable (Havells/Glostar/KEI) with 2X10 SWG GI wire making hole etc. as necy., mending good damages and painting as mentioned below a. on wall by clamp
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below : a. 4 core 50 sqm
b. 4 core 35 sqm
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials . a. 4 core 50 sqm
b. 4 core 35 sqm
Supply & Fixing Bulkhead LED light fittings complete with glass shed, wire net guard on shaft wall.(Philips Signify - ENDURA LED, Cat No- WT202W LED 6S CW PSU S2 PC) as per direction of the Engr-in-charge.
Supply and Fixing of recess mounted round shaped 18W LED Downlight complete with LED Driver (Make,CG, cat no-- CDR-206-18-57SL-NWH) and fixing the same on false celling with own tools & tackles.
Supply and Fixing 4' long twin LED tube fittings ( T.M.C 502 P 2 X T - LED) complete with 2 nos 18 Watt LED tube tube (Philips - 18W W865T8) suspended 25 cm bellow the ceiling with 2 no. 20 mm dia E.I conduit (14 SWG) supports fixed with 'L' type MS clampp whose one side fixed on ceiling with suitable size 4 nos. fastner and other side connected with the conduit with suitable size of bolts and nuts incl. S&F EI conduit "L" type (125 mm x 125mm) 6mm thick and 25 mm with MS clamps and connecting the length of PVC insulated wire and mending good the damages to original finish and painting etc.
Supply and Fixing of recess mounted 2'X2' full glow 36W/40W LED luminaries to be fixed on false ceiling by means of 2 Nos. MS "L" Clamp whose one side fixed on ceiling with suitable size of 2 Nos. fastners and suspended by 12 SWG GI wire connected four side of fittings on exact portion of false ceiling. (Make -Philips Signify -RC365B LED33-6500 PSU OD WH) .
Fixing of Light Fittings :--- Fixing only single/twin fluorescent light fittings suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “L” type MS clamp (125mmx125mm) as per G S
Extra for suspension exceeding 25 cm with S&F additional 2 no. 20 mm dia EI conduit (14 SWG) supports & necy. PVC insulated wire and painting etc. as required by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length as per G S
Fixing of fans :--- Fixing only ceiling fan complete with blades, canopy, fork, rubber bush, etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessary connection as required by 2x1.5 sqmm flexible copper wire as per G.S. Vide page no C-3, Item no 21.a.
Extra for suspension for ceiling fan with 1 x 19 mm dia 2.032 mm (14 SWG) thick E.I conduit including painting.
fixing only 18" (450 mm) Wall Bracket fan with inbuilt on wall by S & F rag bolts ,nuts and washers (6 mm dia x 62 mm long) or as required incl. S & F 24/.20 PVC insulated flexible copper wire 0.5 mt. length
Miscellaneous :--- Supply and installation of 1-Phase timer in double door SPN DB (2+10) way providing incoming and outgoing copper wires and other accessories. The interconnection should be made by 4 sq.mm. copper wires. The box should be painted by powder coated paint. a) 25A DP MCB -1 No. (b)Analog time switch LT240 VAC Base/DIN Mounting cat no-- J648B1 - 1 No. (c) 2- pole single power contactor 250V, 25A coil (Legrand, cat no-- 4125-44) - 1 No. (d) Add-on auxiliary contact block(1 NO+1 NC) -1 no (e) 60A capacity 3 way AC/DC Epoxy terminal block.- 1 No. (f) Indicator Lamp (ESBEE make)-2 Nos. (g) Toggle switch,(ON_OFF_ON)- 1 No. (h) Steel Key Lock – 1 No. (Make- L & T /ABB)
Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Brand approved by EIC), without plug top and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy. connections with PVC Cu wire and earth continuity wir
Supply & Fixing 240 V,25 A, 3 pin Modular type plug top with indicator (Brand approved by EIC) & necy. Connections.
S/F of 230V Digital Control starter ( VOLTCHECK, AMPCHECK & TIMECHECK and 3-digit display) incl. 6 module GI modular switch board for room air conditioner type OLP 21A RAC machine(Electron/Ultratech).
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe/PVC Conduit Pipe and by the prelaid GI fish wire and making necy. connection as required a) 2 X 6 SQmm + 1 X 4 SQ.MM (FOR SPNDB)
b) 2 x 4 SQ.MM + 1 x 2.5 SQ.MM (1PH AC WIRING)
c) 2 X 2.5 SQ.MM + 1 X 1.5 SQ.MM ( FOR POWER PLUG)
d) 3 X 1.5 SQ.MM
Supplying and fixing PVC Rigid Conduit 'FR' [Precision Make] on wall, ceiling with saddles and other accessories as required and mending good damages to building works a) 20 mm size
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes a) 4 SQ. MM
b) 6 SQ. MM
c) 2.5 SQ. MM
Part B :-- Air Conditioning work:-- Dismantling the existing HAT AC machine - 1 No /Split AC machine - 1No at the time of civil renovation work started and after renovation work done refixing same unit to another position as per direction of EIC.
Erection, testing and commissioning charges for the above said 2.0 TR Concealed Split AC & 1 No 1.5 TR Split AC machine.
Refrigeration Piping: Installation and commissioning of hard / soft copper refrigerant piping, complete with fittings, elbows, bends, globe valve of suction & liquid line supporting arrangement on walls incl. S&F of 13 mm thick Nitrile Rubber Insulation tube (Make-Armacell/K-Flex) with supports & brackets as per direction of EIC. a) 5/8” dia 0.8mm Suction Line.
b) 1/4" OD with 0.8 mm thick Liquid Line.. (For 2.0 Tr Machine)
Wrapping both the copper pipe with kenofoam insulation by 26 SWG aluminum sheet to make it vermin proof.
Supply & Charging Refrigerant - 410A
Supply and laying of 3- core 2.5 Sq.mm communication screened Cu. Cable ( MK. KEI /Havell's / Polycab / Finolex)
Supply & Laying Drain Water piping work out of PVC/HDPE hard pipes with Insulation, fitting, accessories, bends, elbows, tees, flanges, tappings, wall sleeves, hangers, supports, anchors.(Mk. Oriplast / Supreme) (i) 25mm dia
Special Terms and Conditions 1. It is stated that the above work place is existing COVID Hospital, In case of any mishap or accidental to any staff that deputed by the agency the whole responsibility is to be borne by the concern agency. 2. The Agency shall be responsible for provisioning of all COVID safety measures including regular sanitiziation of work places, vaccination of employees and compliance of stated directive and COVID appropriate norms. 3. All the issues related to the safety of the staffs should be taken care by the agency itself. (Defect Libilities period for 01 year from the date of completion of work) (Rate should be quotated including all taxes and duties)
S. A. ENTERPRISE
ALPHA ELECTRICALS
technical_1470801.pdf
PDF • 0.22 MB
techsummary_1470801.pdf
PDF • 0.22 MB
finance_1470801.pdf
PDF • 0.22 MB
BOQ Comparative Chart
xlsx • 0.01 MB
finsummary_1470801.pdf
PDF • 0.50 MB
ACNo34.pdf
PDF • 0.59 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .