Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.7 LAccepted-AOC | L1 | Accepted-AOC The lowest tenderer | |
| 2 | L2₹36.9 L+₹5.2 L (16.5%)Rejected-Finance | L2 | Rejected-Finance Not the lowest tenderer | |
| 3 | L3₹37.5 L+₹5.8 L (18.3%)Rejected-Finance | L3 | Rejected-Finance Not the lowest tenderer | |
| 4 | L4₹37.7 L+₹6.0 L (19.0%)Rejected-Finance | L4 | Rejected-Finance Not the lowest tenderer |
Tender Value
Refer Docs
EMD Value
₹85,500
Closing Date
29 Feb 2024, 6:00 pmClosed
HQ CWE SRI GANGANAGAR
HQ CWE POST BOX 48 SRI GANGANAGAR-335001 (Rajasthan)
PROVN OF TRG SHED WITH SUITABLE SIDE COVER AT BDE SAND MODEL ROOM AT MIL STN ABOHAR
2024_MES_640498_1
CA NO CWE SGNR T/ 64 OF 2023-24
Open Tender
Civil Works
Item Rate
180 days
GE ABOHAR
As per NIT
9 documents required · 9 mandatory
₹500
GE ABOHAR
₹85,500
15 Mar 2024
3 Feb 2024
2 Mar 2024
3 Feb 2024
29 Feb 2024
16 Feb 2024
Amount
Surface excavation n.exc 30 cm deep and averaging 15cm deep and getting out In soft/loose soil complete all as specified and directed by Engineer-in-Charge.
Earth work in excavation by mechanical means (Hydraulic excavator) means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out in all kind of soil and disposal of excavated earth lead upto 50 m and lift upto 1.5m, as directed by Engineer-in charge.
Earth work in excavation by mechanical means (Hydraulic excavator) means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out in all kind of soil and disposal of excavated earth lead upto 50 m and lift from 1.5m to 3.0m, all as directed by Engineer-in charge.
Earth work in excavation by mechanical means (Hydraulic excavator) in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. in all kind of Soil complete all as specified and directed by Engineer-in-Charge.
M & L PCC (1:2:4) type B2 using 40mm gradewd stone aggregatefor footing, plinth beam, dwarf wall & toe wall complete all as specified and directed by Engineer-in-Charge.
M & L for Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in any type of soil complete all as specified and directed by Engineer-in-Charge.
M &L for Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point in any type of soil complete all as specified and directed by Engineer-in-Charge.
M & L for RCC- M-25 (Design Mix) using 20mm graded aggregate For Footing, Including rafts as mass concrete & Plinth beam complete all as specified and directed by Engineer-in-Charge.
M & L for Form work for rough finished surfaces of concrete measured flat for side of footing, plinth beam complete all as specified and directed by Engineer-in-Charge.
S & F TMT bars 10mm dia & over of Grade Fe 500D incl cutting, bending, binding & placing in position with binding wire not less than 0.9mm dia or secure with clumps complete all as directed by Engineer-in-Charge.
S & F TMT bars 6mm to 8mm dia & over of Grade Fe 500D incl cutting, bending, binding & placing in position with binding wire not less than 0.9mm dia or secure with clumps complete all as specified and directed by Engineer-in-Charge.
All as per Ser item No 11.00 above but 5 to 10mm dia in stirrups, spacers & binders.
M & L RCC- M-25 (Design Mix) using 20mm graded aggregate for Pedestal upto plinth level complete all as specified and directed by Engineer-in-Charge.
M&L for Form work for rough finished surfaces of concrete measured flat for Pedestal upto plinth level & column finished fair flat surfaces complete all as specified and directed by Engineer-in-Charge.
M & L brickwork with fly ash bricks, straight or curved on plan exc 6m mean radius, built in CM (1:6) complete all as specified and directed by Engineer-in-Charge.
M & L RCC- M-25 (Design Mix) using 20mm graded aggregate for tie beam complete all as specified and directed by Engineer-in-Charge.
M & L for Form work for rough finished surfaces of concrete measured flat for side of tie beam complete all as specified and directed by Engineer-in-Charge.
M & L for 5mm thick rendering on fair faces of brick work or concrete surfaces in CM (1:3 ) finished even and smooth (without using extra lime or cement) on Ceiling complete all as specified and directed by Engineer-in-Charge.
M & L 15mm thick cement plaster, One Coat of 10mm thk in C.M. (1:6) & Second coat of 5mm Thick in CM (1:4) even & smooth without Using Extra Cement complete all as specified and directed by Engineer-in-Charge.
Supply only integral water proofing compound, ISI Marked.
M & L for two coats of colour acrylic emulsion over a coat of primer over a coat of wall care putty complete all as specified and directed by Engineer-in-Charge.
M & L Hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed by Engineer-in-Charge.
M & L 100mm thick Cement Concrete type B-2, 1:2:4 (40mm graded stone aggregate) complete all as specified and directed by Engineer-in-Charge.
M & L for 75mm thick PCC (1:3:6) using 20mm graded aggregate as in plinth protection complete all as specified and directed by Engineer-in-Charge. Note :- Width of plinth protection will be 750mm or as directed by Engineer-in-Charge.
M &L for Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc including one shop coat of zinc chromate primer including preparation of surface.
S&F Mild steel bolts, dia of neck exc 20mm n.exc 25mm purpose made. with hexagonal or square head one end and screwed the other, or screwed both ends; each screwed end to be fitted with washers and one hexagonal or square nut. exc 30cm long complete all as specified and directed by Engineer-in-Charge.
S & F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws as specified and directed.
S & F Pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws as specified.
M&L for preparation of new steel surfaces of any description over 10cm width or girth and applying a coat of red oxide zinc chrome primer and two coats of synthetic enamel paint (for steel surfaces) including preparation of surface complete all as specified.
M & L Machine cut kota stone slab flooring 20 - 25 mm thick over cement screed base laid over and including 20mm thick screed bed in cement mortar 1:4 set and jointed with grey cement slurry mixed with pigment to match of the slab including rubbing and polishing ,Chamfering and nosing complete all as directed.
Demolition of cement concrete (un-reinforced) in floors / pavings, (below or above ground level) and of any description and in any position not otherwise complete all as specified and directed by Engineer-in-Charge.
M&L for 75 mm thick PCC (1:2:4) type B1 (using 20mm graded stone aggregate) as in floor finishing even and smooth without using extra cement complete all as specified.
M & L for chequered cement concrete tiles of size 25cm x 25cm x 25mm thick with grey cement & pigment laid in floors, set and jointed in neat cement slurry and pointed with grey cement and pigment to match the shade of tiles over and including 15 mm thick screed bed or bedding layer of cement mortar (1:6) over complete all as specified and directed by Engineer-in-Charge.
S & F LED Flood light 100 watt, 230 volts, AC indoor type with thermal magnet in multiple optics and equipped with IP 66 protection, with impact and corrosion resstant complete with driver and lamp.
S & F LED street light luminaitres 20/25 watts with IP66 complete with pressure dia cast aluminium housing with GI pipe bracket made out of 25 mm dia medium grade pipe (45 cm long) bend to shape including fixing arrangement to wall with MS flat 25x3mm-2 Nos by nut, bolts and washers including electric connection with PVC copper flexible twin core cable 1.0 sqmm from ceiling rose to light fitting complete all as specified and directed by Engr-In-charge.
Material and labour for Surface mounted PVC conduit Point wiring for one light point/fan point /bell point controlled by one switch (using red, black and green colour wires as colour coding) complete with 1.5 Sqmm (nominal cross section area) single core FRLSH PVC insulated unsheathed and multi strand copper conductor cable 1100 volt (ISI marked) drawn through PVC casing & caping including with all fittings and all accessories i.e. pipe bend, pipe hook, elbow, junction boxes, 3 mm thick bakelite sheet top cover (ISI Marked) fitted with Chromium plated brass screws & washers for paino type fittings and for 2mm thick galvanised steel pressed sunken box suitable for modular switch socket (Min 60mm deep, suitable length) concealed in wall, including inner and outer plates (cover plate) suitable for fixing the modular switches/ socket / regulator etc, including provn of 2.5 Sqmm single core FRLSH PVC insulated multi strand copper conductor wire continues as earth wire connected to earth dolly etc. including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc. by using CM (1:3) complete all as specified and as directed. Note : switches/ socket / regulator shall be measured and paid separately under respective item of BOQ.
All as per ser item No 36.00 above but one 5 pin socket out let 5 amps on the same board with other switches.
All as per ser item No 36.00 above but one 5 pin, 5A switch socket outlet point on independent board.
All as per ser item No 36.00 above but with 2.5 sqmm cable for 1No 16 amps socket outlet point on independent board including 2.5 sqmm PVC insulated unsheathed cable multistranded with copper conductor green in colour as earth continuity conductor all as specified.
Supply and fixing modular switch 5/6Amps, single pole, one way (1 module) complete all as specified and as directed by Engineer-in-charge. Note :- Inner/Outer plate for fixing the switch shall be included in point wiring item of BOQ.
Supply and fixing modular Socket outlet multipurpose type 6 Amp, flush type (2 module) complete all as specified and as directed by Engineer-in-charge. Note :- Inner/Outer plate for fixing the switch shall be included in point wiring item of BOQ.
Supply and fixing modular switch 6/16Amps, single pole, one way (1 module) complete all as specified and as directed by Engineer-in-charge. Note :- Inner/Outer plate for fixing the switch shall be included in point wiring item of BOQ.
Supply and fixing modular Socket outlet multipurpose type 6/16 Amp, flush type (2 module) complete all as specified and as directed by Engineer-in-charge. Note :- Inner/Outer plate for fixing the switch shall be included in point wiring item of BOQ.
M&L for ceiling rose surface type, 65mm x 50mm three terminals, 3 phase / PVC / polycarbonate isolated body all as specified.
Supply and laying XLPE insulated stranded and PVC sheathed heavy duty armoured electric cable with stranded aluminium conductor 1100 volts grade confirming to IS-1554 cross sectional area 35 Sqmm 3.5 core including thimbles/lugs complete with & including passing through pipe along wall, under road crossing/Nallah/Under floor etc all as specified and direcated by Engr-in-Charge. Note :-Earth work, sand cushioning , GI Pipe protection & brick protection to be measured and paid separately.
S & F of MCB distribution board double Door of sheet metal TPN 4 way with 415 Volts complete all as specified and directed.
S & F MCB TPN 40 to 100 Amp, 415 Volts, 10 KA C curve complete with connection testing and commissioning specified and directed by Engineer-in-Charge.
S & F MCB SP 5 to 32 Amp, 240 Volts, 10 KA C curve complete with connection specified and directed by Engineer-in-Charge.
M&L for Sand filling under flooors, in trenches or in foundation for cable protection including and consolidation complete all as specified and directed by Engr-In-Charge.
S&F un-reinforced precast concrete cable cover class LV, type I, flat, size 250 mm x 150 mmx40mm laid flat length of cover across the length of cable a complete all as specified and directed by Engr-In-Charge.
G S CONSTRUCTIONS
SHRI SHYAM CONSTRUCTION CO.
RANDHIR AND COMPANY
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .