Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.8 LAccepted-AOC 11 82 GROUND FLOOR BLOCK 11 KALYANPURI EAST DELHI DELHI 110091 | EAST DELHI | DELHI | 110091 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹21.8 L+₹2.0 L (10.2%)Rejected-Finance | L2 | Rejected-Finance Higher Bidder | |
| 3 | L3₹26.9 L+₹7.1 L (35.6%)Rejected-Finance | L3 | Rejected-Finance Higher Bidder |
Tender Value
₹25.0 L
EMD Value
₹49,980
Closing Date
18 Jan 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SH A K SINGH SE CWE NAVY VASCO
CWE NAVY VASCO VASCO DA GAMA GOA 403802
UPKEEP OF EM INSTALLATIONS AND CONNECTED WORKS AT HQ GNA NIH 2W DET NCB INHS JEEVANTI UNDER GE GOMANTAK VASCO
2021_MES_496507_1
85508/E8
Open Tender
Civil Works
Item Rate
180 days
CWE NAVY VASCO
AS PER TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
Yes
GE GOMANTAK VASCO
₹49,980
Yes
23 Feb 2022
21 Dec 2021
20 Jan 2022
21 Dec 2021
18 Jan 2022
4 Jan 2022
60 days
Amount
Disconnecting HT/LT cable and earthing connections of burnt/defective transformer of capacity 500 to 750 KVA , 11 KV/433 volts 3 phase from pole/floor mounted, taking from site of installation carefully with the help of Crane and transportation of the same to workshop for repairs, draining out the transformer oil, dismantling complete and taking out the core assembly and removing burnt out windings, dehydrating the core assembly, reassembling transformer after repair, replacement of complete gasket set, refilling the oil duly filtered / dehydrated, topping up with new oil, carrying out routine tests, welding work, leakage repairing and complete servicing including transportation back to site, testing and commissioning of the repaired transformer at site on full load after making cable and earthing connections complete all as specified and as directed. Note :- New transformer oil, Dehydration of transformer oil, LT /HT bushings/studs shall be measured and paid separately.
All as per item No 1 here in before but 200 KVA to 315 KVA all as specified and as directed.
All as per item No 1 here in before but 63-160 KVA all as specified and as directed.
M&L for rewinding in repair of HT winding with Copper strip of suitable size/gauge, fixing the coil in position in core assembly and making connection as per original pattern including providing insulation, varnish, all as specified and as directed
(a) Transformer 500 - 750 KVA capacity
(b) Transformer 200 - 315 KVA capacity
(c) Transformer 63 - 160 KVA capacity
All as per item No. 4 here in before but LT limbs of following capacities :-
(a) Transformer 500 - 750 KVA capacity
(b) Transformer 200 - 315 KVA capacity
(c) Transformer 63 - 160 KVA capacity Notes for item No 4 & 5 : i) Guarantee of one year will be provided by the contractor for rewinded limb.
S&F in repairs brass metal studs nut & washers suitable for 11 KV HT side of transformer 63 KVA to 750 KVA all as specified and as directed
S&F in repairs brass metal studs nut & washers suitable for 11 KV LT side of transformer 63 KVA to 750 KVA all as specified and as directed
S&F in repairs HT bushing suitable for 63 KVA to 750 KVA Transformer complete all as specified and as directed
S&F in repairs LT bushing suitable for 63 KVA to 750 KVA Transformer complete all as specified and as directed
M & L for repair of conservator unit complete by gas welding stopping oil leakage including testing , commissioning complete for satisfactory operation of transformer upto 750 KVA capacity all as specified and as directed
M & L for repair of off load tap changer of transformer upto 750 KVA complete all as specified and as directed
S & F Temperature gauge suitable size for transformer of capacity 100 KVA to 750 KVA all as specified and as directed
S & F Level indicator glass of existing size of the transformer of any capacity including replacement of allied gaskets complete and draining out transformer oil from conservator all as specified and as directed
Supply and replace in repairs of fabricated transformer HT/LT cable box cover plate suitable for HT/LT side of transformer as per existing thickness with necessary cutting, bending making holes including making sheet in required shape alongwith gasket, nut, bolts, washers etc and including painting two coats as per existing painting for transformer, capacity upto 63 to 750 KVA all as specified and as directed
Supply and fill in repairs existing breather silica gel of superior quality for transformer breather all as specified and as directed
S&F in repairs transparent PVC material breather assembly for transformer upto 750 KVA capacity all as specified and as directed
M & L for transformer oil filtration & dehydration by Ultra High Vacuum Double stage machine to remove impurities from oil such as moisture, dirt, air and other gases and to improve BDV upto 50KV at 2.5mm air gap all as specified and as directed. Note: Transformer oil filtration & dehydration by Ultra High Vacuum Double stage machine shall be done on existing installation place on same day.
M&L for new transformer oil for topping up or for replacement in Transformers /Servo Voltage stabilizer complete all as specified and as directed Note: Oil shall be in company sealed barrel having BDV not less than 60 KV
M & L for servicing of 11 KV indoor Vacuum Circuit breaker of any make at Gomantak /Jeevanti /2W DET sub station which includes disconnecting ,removing old grease ,re-greasing of moving parts with recommended grease and checking of the entire breaker trolley mechanism, checking of the closing and tripping time in milli seconds using high precision time scope timer, measurements of contact resistance and insulation values, cleaning the complete VCB by opening front and back doors, tightening of cable connections, checking & repairing the current circuit panel wiring, relay, etc and re-assembling & re-installing the VCB back to its original position including testing and commissioning after repair work all as specified and as directed
M & L for Servicing of your 11 KV indoor Load break switch with Fuses of any make at Gomantak /Jeevanti /2W DET /NAD sub station which includes disconnecting ,removing old grease ,re-greasing of moving parts with recommended grease and checking of the entire load breaker system, checking of the closing and tripping time in milli seconds using high precision time scope timer, measurements of contact resistance and insulation values, cleaning the complete LBS by opening front and back doors, tightening of cable connections, etc and re-assembling & re-installing the LBS back to its original position including testing and commissioning after repair work all as specified and as directed Notes for item No 19 & 20 : (i) The cost for minor spares such as screws, nuts, bolts, washers ,indicating lamps, etc shall be included in the rate quoted for the item . (ii) Major Parts will be measured and paid for separately under respective item of sch.
Supply, Erection of 11KV Bus support insulator cylindrical type with double hole/single hole (as per site requirement) for indoor VCB /LBS/HT bus bar Panel including disconnecting & dismantling of faulty bus insulators complete all as specified and as directed
Supply, Erection of 11KV Bus support insulator angular type (as per site requirement) for indoor VCB /LBS including disconnecting & dismantling of faulty bus insulators all as specified and as directed
S&F Space heaters 1000 watts including suitable thermostat for 11 KV VCB including disconnecting & dismantling of faulty one complete all as specified and as directed
S&F Power pack with input of 240 V , AC and ouput of 30 V DC all as specified and as directed
S&F Power pack with input 110V AC ,output 110V DC ,100 VA as suitable for 11 KV VCB panel complete all as specified and as directed
Dismantling and removing the existing unserviceable Over current & Earth fault relay of HT VCB panel and Supply and fixing microprocessor Numerical overcurrent and earth fault relay of VCB, complete all as specified and as directed
S&F Flexible jumpers in load breaker switches all as specified and as directed
S&F Tripping Neutral switches in VCB all as specified and as directed
S&F LED Indicators in VCB/Panel as per existing colour codes all as specified and as directed
S&F Mushroom head push turn all as specified and as directed
S&F Flush head all as specified and as directed
S & F in replacement vacuum interrupter type VL 35414C3 suitable for 11 KV VCB, complete all as specified and as directed
S & F in replacement vacuum interrupter Vacuum Interrupter Type VG 2 all as specified and as directed
S & F in repairs motor charged mechanism assembly UMG-14 with motor & opening coils Code 541/SP for 11 KV VCB all as specified and as directed
S & F in repairs big cam with main shaft with bearing & cover code 568/SP1 for 11 KV VCB all as specified and as directed
S & F in repairs closing coil assembly for 11 KV VCB code 594/SP1 II all as specified and as directed
S & F in repairs triping coil assembly for 11 KV VCB code 599/SP1 ll all as specified and as directed
Shifting of transformer from one site to another in case of emergency by disconnecting HT/LT cable and earthing connections of transformer of capacity 300 to 750 KVA , 11 KV/433 volts 3 phase floor mounted incl making all electrical connections at the place of installation complete all as specified and as directed. Notes :- (i) The rate for transport and lifting of transformer by crane is deemed to be included in the rate quoted. (ii) The rate is deemed to be inclusive for disconnection & making connnections of transformer as required.
Servicing and repair/maintenance of APFC panel Board heavy duty auto/ manual operation including repairs/replacement of fuses, fuse link, contactors, current transformers and checking, replacing of defective control wiring if any replacement of defective cable lugs, patch work welding, replacement of defective door hinges including painting with two coat of sythetic enamel paint etc and testing and commissioning complete upto 75 KVAR all as specified and as directed. Notes : (i) Capacitor /Contactor /MCB will be measured and paid for separately as "Supply only". (ii) Rate for fixing the Capacitor/Contactor/MCB deemed to included in the rate quoted by the Contractor.
Supply only Power Capacitor SQR EHDLL 440V 50HZ-10KVAR 3PH B32459L5010A 11 complete all as specified and as directed
Supply only Power Capacitor SQR EHDLL 440V 50HZ-5KVAR 3PH B32459L5005A 11 complete all as specified and as directed
Supply only Phase cap capacitor 440V 50Hz 15KVAR 3PH B25667L4247A375 complete all as specified and as directed
Supply only Phase cap capacitor 440V 50Hz 20KVAR 3PH B25667L4347A375 complete all as specified and as directed
Supply only Capacitor duty contactor suitable for 5 KVAR to 20 KVAR capacitors all as specified and as directed
Supply only MCB TP 16A -40A ,50 HZ complete all as specified and as directed
S & F Digital Programmable Voltmeter of range 50V-500V, AC complete all as specified and as directed
S & F Digital Programmable Ammeter of range 5A (0.00- 6.00 A), AC complete all as specified and as directed
S & F Power factor Controller suitable upto 75 KVAR APFC Panel all as specified and as directed
S & F three phase multimeter for LT Panel complete all as specified and as directed
M & L for ACSR conductor on existing poles including dismantling of unserviceable ACSR conductor all as directed and as specified.
Dismantling old cross arms MS clamp and angle from LT/HT all as specified and as directed
M&L for cross arm bracing support to clamps and back plate fabricated from slructural steel section like angles channels flat etc including nuts bolts and washers welding bending cold or hot drilling holes for bolts if any shape and size and including applying two coats of aluminium paint over one coat of red oxide primer all as specified and as directed
Supply & Fix Heavy gang operated triple pole mechanically operated air break on load disconnecting switch each pole consist of galvanised iron base HT 11KV with polymer insulators per phase non ferrous knife and spring loaded contact GI pipe of adequate length for operation from ground level and operating handle complete in both OFF and ON position capacity 400 Amps including taking down old one complete all as specified and as directed
M & L for 11 KV Heavy Drop Out Fuse complete in each pole consist of galvanised iron base HT 11KV with polymer insulators including taking down old one all as specified and as directed.
S & F lightening arrestor HT 11000 KV pole mounting with polymeric insulator complete with all fittings transmission class nominal discharge current upto 65 KA including removing the defective one all as specified and as directed
S&F Operating Rod Fibre reinforced plastic connected to main GOAB Switch make arrangement operating from ground level all as specified and as directed
M&L for HT 11 KV Disc type insulator with hardware, single disc assembly, polymeric insulator, vitreous 145 mm high and 255 mm dia and socket type, including taking down old unserviceable all as specified and as directed
S&F for Pin type polymer insulator including one galvanised mild steel spindle two GI washers and one GI iron nut 150mm height, 150mm dia for 11 KV grade including dismantling the old U/S insulator.
Supply and applying petrolium jelly on GOD after removing carbon, dust etc all as specified and as directed
M&L for cable jointing kit for 1.1 KV grade cable for straight through ( Heat Shrinkable) joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 25 to 50 Sq mm including dismantling the old burnt cable joint all as specified and as directed
M&L for straight through ( Heat Shrinkable) cable jointing kit for 1.1 KV grade cable complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 70 to 120 Sq mm including dismantling the old burnt cable joint all as specified and as directed
M&L for straight through ( Heat Shrinkable) cable jointing kit for 1.1 KV grade cable complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 150 to 185 Sq mm including dismantling the old burnt cable joint all as specified and as directed
M&L for straight through ( Heat Shrinkable) cable jointing kit for 1.1 KV grade cable complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 240 to 300 Sq mm including dismantling the old burnt cable joint all as specified and as directed
M & L for cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50sqmm to 95 sq mm complete all as specified and as directed
M & L for cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sq mm to 95 sq mm complete all as specified and as directed
M & L for cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sq mm to 95 sq mm all as specified and as directed Notes for Item Nos 63 to 68: Necessary earth work as required is deemed to be included in the rate quoted.
S&F in repair On load change over switch 250A, 4 pole in sheet metal enclosure all as specified and as directed
S&F in repair On load change over switch 400A, 4 pole in sheet metal enclosure complete with necessary fixing arrangement all as specified and as directed
S&F in repair off load change over switch 400A, 4 pole in sheet metal enclosure complete with necessary fixing arrangement all as specified and as directed
S&F in repair MCCB 415V, 3 phase 50 HZ FP 160 Amps breaking capacity 27 KA,Ics = 100% of Icu all as specified and as directed
S&F in repair MCCB 415V, 3 phase 50 HZ FP 200 Amps breaking capacity 36 KA,Ics = 100% of Icu all as specified and as directed
S&F in repair MCCB 415V, 3 phase 50 HZ FP 250 Amps breaking capacity 36 KA ,Ics = 100% of Icu all as specified and as directed
S&F in repair MCCB 415V, 3 phase 50 HZ FP 400 Amps breaking capacity 36 KA ,Ics = 100% of Icu all as specified and as directed
S&F in repair MCCB 415V, 3 phase 50 HZ FP 630 Amps breaking capacity 36 KA ,Ics = 100% of Icu all as specified and as directed
S&F Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 32 x 6 mm copper strip including removing old copper strip all as specified and as directed
S & F hard drawn GI strip 32 x 6 mm buried in ground/fixed on wall including connecting with earth plate/test point including removing the old GI strip all as specified and as directed
S&F in repairs fix test point terminal block made of gun metal 75 mm x 75 mm x 25 mm drilled and screwed including three Nos 8mm dia 25 mm long hexagonal head screws and including provision of suitable MS box made out of 3 mm thick MS sheet to accommodate the terminal block all as directed including necessary paintings and removing the old test point all as specified and as directed
S&F in repairs aluminium strip 25 x 3.15mm fix on porcelin insulator for roof conductor and down conductor above ground level as lightening conductor ( including insulator) for building / store shed all as directed including removing the old strips all as specified and as directed
S&F in repairs air termination single pointed AL rod 12mm dia 300mm long all as specified and as directed
M&L for preparation of old painted surface of installation by removing all dirt, dust, grease, oil etc and painting complete surface including connected accessories with one coat of synthetic enamel paint of approved colour by spray painting including writing of identification SM & MES Nos, capacity etc all as directed for following transformers:-
(a) Transformer 315KVA/500KVA/750 KVA
(b) Transformer 63/100/160/200 KVA
M&L for preparation of old painted surface of installation by removing all dirt, dust, grease, oil etc and painting complete surface including connected accessories with one coat of synthetic enamel paint of approved colour by spray including writing of identification SM & MES Nos, capacity etc all as directed by Engineer-in-Charge for following transformers:-
(a) LT steel tubular pole of any length
(b) LT concrete pole of any length
(c) HT Concrete pole of any length
M&L for preparation of old painted surface of Fire point box/LT Panel by removing all dirt, dust, etc and painting complete surface including connected accessories with one coat of synthetic enamel paint of approved colour including writing of identification all as specified and as directed for the following size:-
(a) LT cubical panel board of size up to110 cm x 80 cm x 35 cm .
(b) LT cubical panel board of size up to 75 cm x 75 cm x 35 cm .
M&L for danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S clamps, bolts and nuts of approved size, for HT , 25 X 20 cm size all as specified and as directed
Supply and lay GI tubing 80 mm dia light grade ISI Mark laid in trench/fix on pole/wall as in cable protection including fittings such as bends elbows reducers all as specified and as directed
M&L for filling and spreading stone aggregate using 40 mm grade trap stone aggregate around 4 pole , 2 pole structure and transformer etc all as specified and as directed
Demolition of brickwork or stone/ boulder masonry, built in cement mortar complete all as specified and as directed
M&L for precast cement concrete block masonry type C1, 1:3:6 using 20 mm graded stone aggregate with solid blocks, exceeding 10 cm in with and setting in cement mortar 1:6 all as specified and as directed
Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and as directed
M&L for rendering 15mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 including finishing the surface even and smooth without using extra cement all as specified and as directed
M&L for applying two coats of cement based paint over a coat of alkali resistance primer including preparation of new plastered surface all as specified and as directed
Supply only HT 11KV D.O fuse element 30 Amps Rating (Pack of 10 fuse) all as specified and as directed
Supply only HT 11KV D.O fuse element 40 Amps Rating (Pack of 10 fuse) all as specified and as directed
S&F Prestressed concrete pole, 11.0 m long. 152mm x 152mm at top and 152mm x 260mm at bottom, class 9 all as specified and as directed Note:Excavation,earthwork and connected items shall be measured and paid separately
Excavation in trenches not exceeding 1.5 m width and not exceeding 1.5m in depth getting out in hard/dense soil all as specified and as directed
Returning filling in including spreading levelling watering and well ramming in layers not exceeding 25 cm in thick using excavated hard/dense soil complete all as specified and as directed
Removal of surplus soil to a distance not exceeding 50 m and depositing where directed
M&L for plain cement concrete type C-2 ,1:3:6 using 40 mm graded granite stone aggregate in foundations, filling and mass concrete including necessary form work complete all as specified and directed.
Supply and laying HT XLPE cable insulated,screened,PVC bedded,galvanised steel strip armoured,electric power cable (Heavy duty) with aluminium conductor ,cross sectional area 95 sqmm 3 core 11 KV grade complete all as specified and as directed
M&L for detection of fault through locating high voltage mobile machine to locate the fault in 11 KV HT cable by giving high voltage surge and to find out exact location of fault complete all as specified and as directed Note:Excavation and earth work will be measured and paid separately
E M CONSTROL SYSTEM
Shine Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .