Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Accepted-Technical 143 INDUSTRIAL AREA PHASE 2 PANCHKULA HARYANA | PANCHKULA | PANCHKULA | HARYANA | Accepted-Technical ok |
| 2 | Accepted-Technical SCF 15 HUDA COMPLEX 184 NEW IDC 124001 | ROHTAK | HARYANA | 124001 | Accepted-Technical ok |
| 3 | Accepted-Technical A 14 INDUSTRIAL HOUSE INDERPURI NEW DELHI 1100012 | NEW DELHI | NEW DELHI | DELHI | 110012 | Accepted-Technical ok |
| 4 | Not Admitted-Fee/PreQual/Technical 322 AGGARWAL MODERN BAZAR C 33 LAWRENCE ROADS DELHI 110035 | DELHI | NORTH WEST DELHI | DELHI | 110035 | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| 5 | Not Admitted-Fee/PreQual/Technical GURUGRAM | GURUGRAM | HARYANA | 122001 | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹14.5 Cr
EMD Value
₹29 L
Closing Date
21 Sept 2026, 1:00 pmClosed
XEN M/GARH W.S MECH. DIVISION, NARNAUL
Executive Engineer, M/Garh W. S. Mech. Divn. Narnaul
Supply, Replacement, Augmentation of HT (33/3.3KV) and LT Transformer, HT VCB Panel and other allied accessories at various pump houses in M/Garh W/S Mech. Division Narnaul
2026_HRY_546188_1
4259-72/9-A Dated 27/08/2026
Open Tender
Pumps/Motors
Works
180 days
XEN M/GARH W.S MECH. DIVISION, NARNAUL
Please refer Tender documents.
3 documents required · 3 mandatory
₹20,000
₹29 L
Yes
XEN-W/S MECH. DIVISION NARNAUL
7 Oct 2026
8 Sept 2026
21 Sept 2026
8 Sept 2026
21 Sept 2026
8 Sept 2026
11 Sept 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply erection & Comissioning power transformer 3.5 MVA 33/3.3 KV with augmentation of 5 MVA power transformer installed at 33 KV sub station of various Pump Houses under ‘OP’ S/Divn. DHBVN, Nahar, Kanina,Buchawas, M/Garh & Simha . Transformer complete with all accessories with 5 year complete warranty {Including ACSR conductor 50 sqmm (Rabbit) , GSL 8SWG G.I Nut and bolt of sizes, eye screw bolt wt. 0.483 kg,} /fitting & conforming to Nigam's technical specification No. CSC-76-R-I/DH/UH/P&D/2015-16 and relevant ISS with latest amendments including all charges i.e Supply, transportation charges/crane charges loading & unloading charges, Fencing & Stone gravels in switch yards area, 4 No. Fire Extingusher with each Transformer, 8x8 feet plinth structure and any type of testing charges i.e. M&P , CEI charges etc. (all type of third party inspection charges during any state inclusive of rate) including Chemical earthing (earthing rod wt. 6.175kg GI pipe 40mm dia 6 mtr. Long earthing set B class, GI strip 25x6mm 9mtr. for earthing wt. 10.80kg, Copper plate earthing for Neutral of transformer, Energy meter, insulator, Cable Dismantlement, Cable erection with 33 KV HT XLPE Cable Termination Kit Single core 630 sqmm (8 No. Indoor Kit & 8No. Outdoor Kit) &1000 sqmm (4 No. Indoor Kit & 4 No. Outdoor Kit) and Commissioning Charges as per site requirement. (at PH MC-1,2,3,4 NB-1,4,5) | 7 | No | - | - |
| 2 | Replacement of 200 KVA 3.3/0.440 KV Distribution transformer with 400KVA 3.3/0.440 KV Distribution transformer {Including ACSR conductor 50 sqmm (Rabbit) , GSL 8 SWG G.I nuts and bolts of sizes, eye screw bolts wt. 0.483 kg, earthing rod wt. 6.175kg GI pipe 40mm dia 6 mtr. Long earthing set B class, GI strip 25x6mm 9mtr. for earthing wt. 10.80kg, Lightening Arrestor 9 KV, HT XLPE cable 3c*50sqmm with TR, Termitation kit O/D 3c*50 sqmm, wodden gutka GI channel 100x50x6mm 2200 mm for holding fuse board, LT fuse board with busbar abd aluminium patti, plinth structure including PCC Pole 11 Mtr. Long, 3.3KV GO switch complete with handle, pipe & supporting channel, Single Core 630 sqmm cable with proper thimbling and any other leftover item if any as per site requirement and spcification appproved by DHBVN Department.} installed at 33 KV sub station Pump House NB-5 | 1 | No. | - | - |
| 3 | Replacement of 100 KVA 3.3/0.440 KV Distribution transformer with 200KVA 3.3/0.440 KV Distribution transformer {Including ACSR conductor 50 sqmm (Rabbit) , GSL 8 SWG G.I nuts and bolts of sizes, eye screw bolts wt. 0.483 kg, earthing rod wt. 6.175kg GI pipe 40mm dia 6 mtr. Long earthing set B class, GI strip 25x6mm 9mtr. for earthing wt. 10.80kg, Lightening Arrestor 9 KV, HT XLPE cable 3c*50sqmm with TR, Termitation kit O/D 3c*50 sqmm, wodden gutka GI channel 100x50x6mm 2200 mm for holding fuse board, LT fuse board with busbar abd aluminium patti, plinth structure including PCC Pole 11 Mtr. Long, 3.3KV GO switch complete with handle, pipe & supporting channel, Single Core 630 sqmm cable with proper thimbling and any other leftover item if any as per site requirement and spcification appproved by DHBVN Department.} installed at 33 KV sub station Pump House NB-1 & 4 | 2 | No. | - | - |
| 4 | Supply, Installation & Commissioning of 1600 KVA Transformer 11 KV/440 V {Including ACSR conductor 50 sqmm (Rabbit) , GSL 8 SWG G.I nuts and bolts of sizes, eye screw bolts wt. 0.483 kg, earthing rod wt. 6.175kg GI pipe 40mm dia 6 mtr. Long earthing set B class, GI strip 25x6mm 9mtr. for earthing wt. 10.80kg, Lightening Arrestor 9 KV, HT XLPE cable 3c*50sqmm with TR, Termitation kit O/D 3c*50 sqmm, wodden gutka GI channel 100x50x6mm 2200 mm for holding fuse board, LT fuse board with busbar abd aluminium patti, plinth structure including PCC Pole 11 Mtr. Long (with Half clamp weight 1.47 kg HVPN Drg. No. 2380, full clamp weight 2.325 kg HVPN Drg. No. 2349, 11KV Polymeric pin with insulator , 11KV Polymeric Disc insulator with fitting (T&C type), Stay set 8 feet long complete with X - Plate 460m of angle 65x65x6mm Elbow & rod Wt.13.80kg , stay wire 7/8 SWG, GI channel 100x50x6mm 2200 mm for H- Pole wt 21.032 kg , GI channel 50x50x6mm 2400 mm for earth wire wt. 10.80kg, GI channel 75x40x6mm 2200 mm for fuse unit wt 15.708kg, GI channel 100x50x6mm 2200 mm for H- Pole wt 21.032 kg,11KV GO switch complete with handle, pipe & supporting channel, Single Core 630 sqmm cable with proper thimbling and any other leftover item if any as per site requirement and spcification appproved by DHBVN Department.} at PH NB-6 | 1 | No. | - | - |
| 5 | Supply, errection & commissioning of 33/3.3 kV VCB, (Indoor type/incommer Panel) with 02 No. 3.3kV outgoing CTR 800/400-5-5A, indoor metal-clad draw out VCB incommer-1250 A & outgoing 630A each, 3.6kV Class, 25kA for 3 second, 62.5kA peak, vecume interpretor, with numerical OC/EF protection, CTs, PT/VT as required, transformer protection trip interfaces, metering, earth switch, interlocks, IAC protection suitable for 33/3.3KV, 5MVA Power Transformer at Sub Station Yard end with complete earthing, lightening Arrestor and all other protections as per DHBVN approved specifications with IEC 62271 series/applicable IS standards. (at PH MC-1,2,3,4 NB-1,4,5) | 7 | No. | - | - |
| 6 | Supply, errection & commissioning of 11 KV VCB Panels set (Set of 01 incoming and 02 outgoing Panels) 25 KA, 475 MVA rupturing capacity, 24V DC operated, indoor type with a set of CTs 400-200/ 5-5A, PTS KWH Meter, Relays, instruments, earthing etc complete in all respect conforming to Nigam's (DHBVN) Tech Set (Set specifications & all relevent ISS/IES with latest amendments. Rating:- 1250 Amps for of 01 IC both incoming & outgoing Panels (Indoor Type) alongwith LT Switchgear 1600 Amps ACB, 4 Pole, Manual Operated, Fixed types with enclosures & with copper bush bars. Make:- As per latest list of approved makes by DHBVN at PH NB-6 | 1 | No. | - | - |
| 7 | Supply, laying & installatuion of 33/3.3 KV HT TR-XLPE 1000 sqmm single core armoured Aluminium Cable confirming to IS 7098/(Part-II)1995 (Cable Code A2XCEFaY) as approved make | 1,500 | Mtr | - | - |
| 8 | Supply, laying & installatuion of 3.3 KV HT TR-XLPE 630 sqmm single core armoured Aluminium Cable confirming to IS 7098/(Part-II)1995 (Cable Code A2XCEFaY) as approved make | 1,500 | Mtr | - | - |
| 9 | Supply, laying and installation HT Cable 240 Sq mm, 3.3 KV, Three Core armoured Aluminium Cable as latest ISI specification of approved make by technical committee. (Cable Code A2XCEFY) | 750 | Mtr | - | - |
| 10 | Supply, laying and installation of LT 1100 Volts Cable PVC XLPE armoured Aluminium Conductor of sizes as mentioned as per relevant IS specification & approved make as per annexure-c in technical specification (Cable Code A2XWaY/A2XFaY) 1. Single Core 1000 Sq. MM | 750 | Mtr | - | - |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.46 MB
BOQ_625808.xls
BOQ • 0.29 MB
Approvedmake.pdf
Other Document • 0.82 MB
Bidbook11.pdf
Additional Documents • 0.34 MB
AnnexureC.pdf
Other Document • 11.56 MB
CORRIGENDUMDATE.pdf
PDF • 0.28 MB
CORRIGENDUM.pdf
PDF • 0.90 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .