RequiredOEM Authorization Certificate Bid to RA enabled Yes Table Top Autoclave ( 1 pieces ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Bid Requirement (Allowed Values) Accessories
RequiredConsumables & Warranty Accessories: Each Tabletop autoclave unit shall be supplied along with: One Rack unit with 5 levels and one set of suitable sized instrument trays. Each Tabletop autoclave unit shall be supplied along with: One Rack unit with 5 levels and one set of suitable sized instrument trays. Warranty 3 3
Required5 Or higher Consumables: Sterilizer unit to be supplied with sufficient for 50 sterilization cycles sufficient for 50 sterilization cycles
Requiredsufficient for 100 1/5 consumables sufficient to carry out sterilization cycles (No) sterilization cycles Or higher Configuration Type Table top or bench top steam steriliser * Type of cycle processes available B-process
RequiredN- process B-process
RequiredN- process Sterilizer Chamber Type Rectangular Circular
RequiredRectangular
RequiredRemovable cassette Steriliser chamber material SS 316 or better grade steel * Working Pressure of Chamber 2.2 * Design Pressure of Chamber 3.8 * Chamber pre- heating facility: Equipped with electrically heated jacket for preheating on standby mode: Yes Yes Type of Sterilizer Chamber Door Radially Opening Door Radially Opening Door Steriliser Chamber door Locking facility At least two locking bolts * Sterilizer Chamber door Operation: Manual Manual
RequiredAutomatic (with manual override facility in case of auto mechanism failure) Door sealing: By elastomeric rubber gasket suitable to withstand temperature upto 140 degree C & pressure upto 20-30 psi * Inlet Air Filtration: Yes
RequiredAtmospheric air shall enter the sterilisation chamber after its filtering by a disposable air filter provided in the equipment. * Air Filter efficiency: >= 99.998% * Sterilising Cycle Processes available: 121 degree C Wrapped
Required134 degree C Wrapped
Required134 degree C Flash/Rapid open instrument cycle
Required134 degree C textile
RequiredTest programs: Bowie & 121 degree C Wrapped
Required134 degree C Wrapped
Required134 degree C Flash/Rapid open instrument cycle
Required134 degree C textile
RequiredTest programs: Bowie & 2/5 Dick
RequiredLeak Test Dick
RequiredLeak Test Water Storage Tank: Inbuilt water reservoir with Storage capacity of 3-5 litre with easy access for cleaning to avoid biofilm available: Yes * Steriliser have inbuilt steam generator designed for integrated energy storing system for building up power for sterilisation load in shot time: Yes Yes Type of control system available for Steriliser cycle operation: Microprocessor based PLC system specifically designed for sterilisation operations
Requiredwith CPU processor with battery back up
Requireddigital input/output controls
Requiredanalog measuring inputs & COM ports for printer and PC connectivity. Automatic process checking
Requiredself checking of safety devices and failure correction should be possible by the control system. * Power Source: 220 Volt
Required50 Hz AC electric supply * Power supply: 220 volt
Required50 Hz AC electric supply single phase * Number of Trays in sterillser chamber 4 2
Required3
Required4
Required5 Or higher Sterilliser Loading Type: Front loading Front loading Audio- visual Alarm facility available for notifying: Temperature sensor failure
RequiredPressure sensor failure
RequiredPhase time out
RequiredDoor improperly closed
RequiredPower failure (no alarm if duration of power failure < 10 sec)
RequiredSafety device malfunctioning
RequiredLow water level Temperature sensor failure
RequiredPressure sensor failure
RequiredPhase time out
RequiredDoor improperly closed
RequiredPower failure (no alarm if duration of power failure < 10 sec)
RequiredSafety device malfunctioning
RequiredLow water level
RequiredCassette improperly closed 3/5 Overall Size Overall Height: 400 * Overall Width: 560 * Overall Depth: 580 * Quality and Certifications Compliance of Chamber for Chamber Pressure Equipment Directives (PED) AND EN 13445 norms: Yes Yes Quality Compliance available for quality systems as per as per ISO 9001:2000
RequiredEN ISO 13485:2003
RequiredISO 14001:2004: Yes Yes
RequiredNo Certifications: US FDA
RequiredEuropean CE US FDA
RequiredEuropean CE * Specifications highlighted in bold are the Golden Parameters. * Bidders may note that In respect of non-golden Parameters
Requiredthe specifications 'Values' chosen by Buyer will generally be preferred over 'Bid requirement ( allowed Values) by the Buyer.