Loading…
Loading…
Tender ID
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.3 LAdmitted-Finance GROUND FLOOR F 11 PHASE II MAYAPURI WEST DELHI DELHI 110064 | DELHI | WEST DELHI | DELHI | 110064 | L1 | Admitted-Finance | |
| 2 | L2₹31.6 L+₹1.4 L (4.53%)Admitted-Finance RZ 18 260 WEST SAGARPUR NEAR MCD SCHOOL NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | L2 | Admitted-Finance | |
| 3 | L3₹33.2 L+₹2.9 L (9.55%)Admitted-Finance WZ 576 577 NANGAL RAYA NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | L3 | Admitted-Finance | |
| 4 | L4₹34.8 L+₹4.6 L (15.0%)Admitted-Finance | L4 | Admitted-Finance | |
| 5 | L5₹35.8 L+₹5.6 L (18.4%)Admitted-Finance | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | M/s S.G. BUILDERS L4 | Shiv Enterprises L3 | NEETU TRADERS (INDIA) L8 | Surjit and Sons L9 | D P ENTERPRISES L5 | P S TRADERS L2 | Ruchi enterprises L7 | AMIT ENTERPRISES L1 | PARMAR ENTERPRISES L6 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Supply and fix in replacement Aluminium strip 25 x 3.15mm with saddles and fixing screws etc. for roof conductorsand down conductors above the ground level | 12,000 | RM | 123 ₹14,76,000 | 75 ₹9,00,000 Lowest | 130 ₹15,60,000 | 100 ₹12,00,000 | 90 ₹10,80,000 | 85 ₹10,20,000 | 147 ₹17,64,000 | 88 ₹10,56,000 | 139 ₹16,68,000 |
| 2.00 | Supply and fix in replacementGI strip 32x6mm burried in ground as earthing loop | 5,060 | RM | 175 ₹8,85,500 | 55 ₹2,78,300 | 245 ₹12,39,700 | 150 ₹7,59,000 | 70 ₹3,54,200 | 95 ₹4,80,700 | 128 ₹6,47,680 | 44 ₹2,22,640 Lowest | 160 ₹8,09,600 |
| 3.00 | Supply and fix in replacement single pointed air termination aluminium rod 12 mm dia ,300 mm long. | 180 | Each | 299 ₹53,820 | 200 ₹36,000 | 325 ₹58,500 | 100 ₹18,000 Lowest | 100 ₹18,000 Lowest | 140 ₹25,200 | 100 ₹18,000 Lowest | 299 ₹53,820 | 189 ₹34,020 |
| 4.00 | M&L for earthing with copper steel earth plate electrode 60cm x 60cm x 3.15mm thick buried directly in ground vertically at a depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level, earth plate surrounded from all sides by 15cm thick packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by using copper strip of size 20mm x 3mm as earthing lead upto the body of the equipment by means of bolts, nuts, check nuts and washers made of copper and thimbles and protected by light grade 40mm dia GI pipe connected to main switch board or main control board and GI pipe medium grade 20mm bore for watering and including funnel, wire mesh, RCC pit cover and PCC chamber pit with PCC 1:3:6 type C-2 using 40mm graded stone aggregate, including excavation and earth work in any type of soil, returning, filling in approved soil and disposal of surplus soil to a distance not exceeding 50m all as specified and shown in electrical plate No 3 of SSR 2009 (Part-I) complete all as specified and as directed.
Note:- On testing after completion if the desired earth resistance is not obtained the earthing will be be redone without any extra cost. | 72 | Each Job | 11,999 ₹8,63,928 Lowest | 27,000 ₹19,44,000 | 16,500 ₹11,88,000 | 30,000 ₹21,60,000 | 27,800 ₹20,01,600 | 20,100 ₹14,47,200 | 19,500 ₹14,04,000 | 19,999 ₹14,39,928 | 17,500 ₹12,60,000 |
| 5.00 | Test point Terminal block made of gun metal or phosphorus bronze size 75x75x25 mm drilled and screwed including 3 nos, 8mm dia, 25mm long hex head screw complete all as directed | 72 | Each | 575 ₹41,400 | 1,000 ₹72,000 | 850 ₹61,200 | 700 ₹50,400 | 750 ₹54,000 | 750 ₹54,000 | 1,100 ₹79,200 | 999 ₹71,928 | 300 ₹21,600 Lowest |
| 6.00 | Supply and fix GI pipe 20mm bore light grade | 300 | RM | 199 ₹59,700 | 150 ₹45,000 | 210 ₹63,000 | 210 ₹63,000 | 120 ₹36,000 Lowest | 290 ₹87,000 | 130 ₹39,000 | 166 ₹49,800 | 180 ₹54,000 |
| 7.00 | Providing cement contrete in block form roof kerbs or mud stops rounged or chamfered on edges of size150x150x300 mm type B1 1:2:4 (20 mm graded aggregate) all as specified and directed. | 0.6 | Cum | 4,000 ₹2,400 | 1,000 ₹600 Lowest | 7,200 ₹4,320 | 4,000 ₹2,400 | 4,000 ₹2,400 | 4,500 ₹2,700 | 2,000 ₹1,200 | 4,444 ₹2,666.4 | 6,000 ₹3,600 |
| 8.00 | S&F LED Based outdoor weatherproof Aviation Obstruction Lighthing with inbuilt AC-DC convertor 48V/160-230 VAC housed in Die-Cast Aluminium (LM 6)/Aviation Orange Finish Ultra violet stablised Acrylic lens for directing light built in photo controller / Buit in SS Bird Spike Soild State high flux light Emitting Diode/Intensity: 32.5 Candelas, IP rating: IP-65, Life:>500000 Hrs/Sealed with EPDM Gasket power supply: AC-DC converter 48V/160-320 VAC standards: confirms to ICAO Annex 14-6, FAA AC No. 70/7460-IG, Radio Interference: BS 800/EN 55014 Connections, necessary welding, clamping, mounting with 32 mm dia GI pioe, 1.2 mtr height, 1.5 sqmm copper wire with 20 mm PVC conduit fixing on work portions upto nine storeys height bldg. incl taking down unsv complete | 18 | Each | 5,500 ₹99,000 | 2,200 ₹39,600 | 9,800 ₹1,76,400 | 5,500 ₹99,000 | 2,000 ₹36,000 Lowest | 2,600 ₹46,800 | 7,000 ₹1,26,000 | 7,200 ₹1,29,600 | 2,900 ₹52,200 |
Tender Value
₹44.2 L
EMD Value
₹88,360
Closing Date
19 Mar 2026, 4:00 pmClosed
GE North Delhi Cantt-10
GE North Delhi Cantt-10
REPAIR REPLACEMENT OF LIGHTENING PROTECTION AVIATION LIGHT EARTHLING AIR TERMINATION ROD IN HIGH RISE BUILDING AT CHEERING ENCLAVE UNDER GE NORTH DELHI CANTT10
2026_MES_753405_1
GE/North-135/2025-26
Open Tender
Civil Works
Item Rate
180 days
GE NORTH DELHI CANTT 10
As per NIT
8 documents required · 8 mandatory
₹500
Yes
GE NORTH DELHI CANTT 10
₹88,360
Yes
7 Apr 2026
19 Feb 2026
23 Mar 2026
19 Feb 2026
19 Mar 2026
5 Mar 2026
Supply and fix in replacement Aluminium strip 25 x 3.15mm with saddles and fixing screws etc. for roof conductorsand down conductors above the ground level
Supply and fix in replacementGI strip 32x6mm burried in ground as earthing loop
Supply and fix in replacement single pointed air termination aluminium rod 12 mm dia ,300 mm long.
M&L for earthing with copper steel earth plate electrode 60cm x 60cm x 3.15mm thick buried directly in ground vertically at a depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level, earth plate surrounded from all sides by 15cm thick packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by using copper strip of size 20mm x 3mm as earthing lead upto the body of the equipment by means of bolts, nuts, check nuts and washers made of copper and thimbles and protected by light grade 40mm dia GI pipe connected to main switch board or main control board and GI pipe medium grade 20mm bore for watering and including funnel, wire mesh, RCC pit cover and PCC chamber pit with PCC 1:3:6 type C-2 using 40mm graded stone aggregate, including excavation and earth work in any type of soil, returning, filling in approved soil and disposal of surplus soil to a distance not exceeding 50m all as specified and shown in electrical plate No 3 of SSR 2009 (Part-I) complete all as specified and as directed. Note:- On testing after completion if the desired earth resistance is not obtained the earthing will be be redone without any extra cost.
Test point Terminal block made of gun metal or phosphorus bronze size 75x75x25 mm drilled and screwed including 3 nos, 8mm dia, 25mm long hex head screw complete all as directed
Supply and fix GI pipe 20mm bore light grade
Providing cement contrete in block form roof kerbs or mud stops rounged or chamfered on edges of size150x150x300 mm type B1 1:2:4 (20 mm graded aggregate) all as specified and directed.
S&F LED Based outdoor weatherproof Aviation Obstruction Lighthing with inbuilt AC-DC convertor 48V/160-230 VAC housed in Die-Cast Aluminium (LM 6)/Aviation Orange Finish Ultra violet stablised Acrylic lens for directing light built in photo controller / Buit in SS Bird Spike Soild State high flux light Emitting Diode/Intensity: 32.5 Candelas, IP rating: IP-65, Life:>500000 Hrs/Sealed with EPDM Gasket power supply: AC-DC converter 48V/160-320 VAC standards: confirms to ICAO Annex 14-6, FAA AC No. 70/7460-IG, Radio Interference: BS 800/EN 55014 Connections, necessary welding, clamping, mounting with 32 mm dia GI pioe, 1.2 mtr height, 1.5 sqmm copper wire with 20 mm PVC conduit fixing on work portions upto nine storeys height bldg. incl taking down unsv complete
stage.html
html • 0.04 MB
technical_843856.pdf
techsummary_843856.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.39 MB
Gen135.pdf
Tender Documents • 0.97 MB
BOQ_843856.xls
BOQ • 0.31 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .