Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹43.0 LAdmitted-Finance | ₹43.0 L | L1 | Admitted-Finance |
| 2 | L2₹44.4 L+₹1.4 L (3.35%)Admitted-Finance 840 1B MADHUR VIHAR COLONY CIVIL LINES JHANSI UP 284 001 | JHANSI | JHANSI | UTTAR PRADESH | 284001 | ₹44.4 L+₹1.4 L (3.35%) | L2 | Admitted-Finance |
| 3 | L3₹44.8 L+₹1.9 L (4.32%)Admitted-Finance A 63 ELDECO COUNTY PHASE II RAJGARH JHANSI U P 284135 | JHANSI | JHANSI | UTTAR PRADESH | 284135 | ₹44.8 L+₹1.9 L (4.32%) | L3 | Admitted-Finance |
| 4 | L4₹45.1 L+₹2.2 L (5.03%)Admitted-Finance 0 BISAI TIKAITGANJ FATEHPUR BARABANKI UTTAR PRADESH 225302 | BARABANKI | UTTAR PRADESH | 225302 | ₹45.1 L+₹2.2 L (5.03%) | L4 | Admitted-Finance |
| 5 | L5₹45.4 L+₹2.4 L (5.59%)Admitted-Finance 00 BHUSAR FARM KE PASS K K PURI NANDANPURA JHANSI UTTAR PRADESH 284003 | JHANSI | UTTAR PRADESH | 284003 | ₹45.4 L+₹2.4 L (5.59%) | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | Dhruv Enterprises L1 | M/s Jagdish Chandra Arora L8 | M/s Indu Enterprises L7 | A K ENTERPRISES L5 | VIJAY BUILDERS L6 | M/S Kumar Contractors L2 | ROHIT ENTERPRISES L3 | ADARSH ENTERPRISES L4 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Attending to daily electrical complaints in the Jhansi Military area by deploying adequate skilled teams (Qualified Electrician and Helper) round-the-clock (24/7) to ensure uninterrupted power supply. Scope includes diagnosing and rectifying defects by replacing unserviceable items (switches, sockets, DBs, light/power MCBs, holders, bells, capacitors, plugs, fans, and geysers). Rate includes minor consumables (insulation tapes, screws) and replacement pieces of multi-stranded single-core copper cable (1.5 sq. mm to 6.0 sq. mm) up to 0.50 meters per complaint, complete as directed by the Engineer-in-Charge
Note:-
(i) Daily signed complaint slips/job cards (in the approved format) are mandatory and shall form an integral part of the running/final bill.
(ii) Major equipment or component replacements (excluding minor consumables and wire patches up to 0.5m) shall be measured and paid for separately under respective items of Schedule 'A'.
(iii) All deployed electricians and helpers shall report to the E/M Yard on a daily basis for complaint assignment and logging. | 3,500 | Each Job | 200 ₹7,00,000 Lowest | 350 ₹12,25,000 | 425 ₹14,87,500 | 260 ₹9,10,000 | 270 ₹9,45,000 | 400 ₹14,00,000 | 215 ₹7,52,500 | 235 ₹8,22,500 |
| 2.00 | Supply and fix in replacement fan capacitor 2.5 m.f.d for ceiling Fan, including taking down old unserviceable capacitor all as specified and directed. | 500 | Each | 60 ₹30,000 | 70 ₹35,000 | 60 ₹30,000 | 60 ₹30,000 | 80 ₹40,000 | 30 ₹15,000 Lowest | 80 ₹40,000 | 40 ₹20,000 |
| 3.00 | Supply and fix in replacement fan capacitor 4 m.f.d for Exhaust Fan, including taking down old unserviceable all as specified and directed. | 125 | Each | 80 ₹10,000 | 90 ₹11,250 | 80 ₹10,000 | 70 ₹8,750 | 90 ₹11,250 | 55 ₹6,875 | 100 ₹12,500 | 50 ₹6,250 Lowest |
| 4.00 | Taking down carefully existing copper/aluminium point wiring (light, fan, socket or power) complete of any description wooden boards, laminated sheets from sunken boxes, boards, shades light fitting etc and making good the disturbed surfaces of walls, floors, ceiling etc with cement plaster, putty and paint to match with the existing surface complete all as specified and directed. | 456 | Point | 30 ₹13,680 Lowest | 150 ₹68,400 | 100 ₹45,600 | 150 ₹68,400 | 50 ₹22,800 | 50 ₹22,800 | 100 ₹45,600 | 35 ₹15,960 |
| 4.01Note for serial Item No 5 to 16 : Modular switches, sockets, and fan regulators shall be measured and paid for separately under respective line items | |||||||||||
| 4.02POINT WIRING | |||||||||||
| 5.00 | Material & Labour for point wiring for One light / ceiling fan / exhaust fan / call bell point controlled by one switch, wiring shall consist of 1.5 Sqmm 1100 Volts grade FRLSH insulated, unsheathed, multistranded single core copper conductor cable conforming to IS:694, along with one run of 1.5 Sqmm FRLSH insulated copper conductor cable green in colour for continuous earthing, drawn through and including medium grade rigid PVC conduit conforming to IS:9537 (Pt-III) and its all accessories/junction boxes/ inspection covers etc of suitable size but not less than 20mm(OD), concealed in wall/ floor etc including provision of pressed steel terminal box of thickness not less than 18 SWG / with earth dolly of suitable size concealed in wall and covered with 3 mm thick phenolic laminated hylam sheet fixed with brass/GI screws for mounting switches, sockets, fan regulator, etc. complete all as specified and directed. | 200 | Point | 650 ₹1,30,000 | 750 ₹1,50,000 | 650 ₹1,30,000 | 700 ₹1,40,000 | 780 ₹1,56,000 | 450 ₹90,000 Lowest | 700 ₹1,40,000 | 600 ₹1,20,000 |
| 6.00 | Material & Labour for point wiring for One 6A socket point controlled by one switch on independent board, wiring shall consist of 1.5 Sqmm 1100 Volts grade FRLSH insulated, unsheathed, multistranded single core copper conductor cable conforming to IS:694, along with one run of 1.5 Sqmm FRLSH insulated copper conductor cable green in colour for continuous earthing, drawn through and including medium grade rigid PVC conduit conforming to IS:9537 (Pt-III) and its all accessories/junction boxes/ inspection covers etc of suitable size but not less than 20mm(OD), concealed in wall/ floor etc including provision of separate pressed steel terminal box of thickness not less than 18 SWG / with earth dolly of suitable size concealed in wall and covered with 3 mm thick phenolic laminated hylam sheet fixed with brass/GI screws for mounting switches, sockets, etc. complete all as specified and directed. | 70 | Point | 650 ₹45,500 | 580 ₹40,600 | 450 ₹31,500 | 500 ₹35,000 | 550 ₹38,500 | 250 ₹17,500 Lowest | 475 ₹33,250 | 350 ₹24,500 |
| 7.00 | Material & Labour for point wiring for One 6A socket point controlled by one switch on same board, wiring shall consist of 1.5 Sqmm 1100 Volts grade FRLSH insulated, unsheathed, multistranded single core copper conductor cable conforming to IS:694, along with one run of 1.5 Sqmm FRLSH insulated copper conductor cable green in colour for continuous earthing, drawn through and including medium grade rigid PVC conduit conforming to IS:9537 (Pt-III) and its all accessories/junction boxes/ inspection covers etc of suitable size but not less than 20mm(OD), concealed in wall/ floor etc. Rate shall be inclusive of loop wiring inside the existing master pressed steel terminal box of thickness not less than 18 SWG sharing the same 3 mm thick phenolic laminated hylam sheet cover, including all hardware and its all accessories complete all as specified and directed. | 70 | Point | 350 ₹24,500 | 490 ₹34,300 | 350 ₹24,500 | 400 ₹28,000 | 400 ₹28,000 | 180 ₹12,600 Lowest | 380 ₹26,600 | 300 ₹21,000 |
| 8.00 | Material & Labour for point wiring for One 16A socket point controlled by one 16A switch on independent board, wiring shall consist of 2.5 Sqmm 1100 Volts grade FRLSH insulated, unsheathed, multistranded single core copper conductor cable conforming to IS:694, along with one run of 2.5 Sqmm FRLSH insulated copper conductor cable green in colour for continuous earthing, drawn through and including medium grade rigid PVC conduit conforming to IS:9537 (Pt-III) and its all accessories/junction boxes/ inspection covers etc of suitable size but not less than 20mm(OD), concealed in wall/ floor etc including provision of separate pressed steel terminal box of thickness not less than 18 SWG / with earth dolly of suitable size concealed in wall and covered with 3 mm thick phenolic laminated hylam sheet fixed with brass/GI screws for mounting switches, sockets, etc. complete all as specified and directed. | 20 | Point | 750 ₹15,000 | 1,000 ₹20,000 | 850 ₹17,000 | 900 ₹18,000 | 900 ₹18,000 | 600 ₹12,000 Lowest | 870 ₹17,400 | 750 ₹15,000 |
Tender Value
₹50 L
EMD Value
₹1 L
Closing Date
20 Aug 2026, 6:00 pmClosed
Major Rajesh Rathore
Garrison Engineer Jhansi
PETTY REPAIR PERTAINS TO E/M WORKS IN ZONE A AND B UNDER AGE E/M AT GE JHANSI
2026_MES_781641_1
GE/JHA/TOK/51 OF 2026-27
Open Tender
Civil Works
Item Rate
270 days
GE Jhansi
As per NIT and Tender Documents
8 documents required · 8 mandatory
₹500
GE Jhansi
₹1 L
Yes
2 Sept 2026
30 Jul 2026
22 Aug 2026
30 Jul 2026
20 Aug 2026
13 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Attending to daily electrical complaints in the Jhansi Military area by deploying adequate skilled teams (Qualified Electrician and Helper) round-the-clock (24/7) to ensure uninterrupted power supply. Scope includes diagnosing and rectifying defects by replacing unserviceable items (switches, sockets, DBs, light/power MCBs, holders, bells, capacitors, plugs, fans, and geysers). Rate includes minor consumables (insulation tapes, screws) and replacement pieces of multi-stranded single-core copper cable (1.5 sq. mm to 6.0 sq. mm) up to 0.50 meters per complaint, complete as directed by the Engineer-in-Charge
Note:-
(i) Daily signed complaint slips/job cards (in the approved format) are mandatory and shall form an integral part of the running/final bill.
(ii) Major equipment or component replacements (excluding minor consumables and wire patches up to 0.5m) shall be measured and paid for separately under respective items of Schedule 'A'.
(iii) All deployed electricians and helpers shall report to the E/M Yard on a daily basis for complaint assignment and logging. | 3,500 | Each Job | - | - |
| 2 | Supply and fix in replacement fan capacitor 2.5 m.f.d for ceiling Fan, including taking down old unserviceable capacitor all as specified and directed. | 500 | Each | - | - |
| 3 | Supply and fix in replacement fan capacitor 4 m.f.d for Exhaust Fan, including taking down old unserviceable all as specified and directed. | 125 | Each | - | - |
| 4 | Taking down carefully existing copper/aluminium point wiring (light, fan, socket or power) complete of any description wooden boards, laminated sheets from sunken boxes, boards, shades light fitting etc and making good the disturbed surfaces of walls, floors, ceiling etc with cement plaster, putty and paint to match with the existing surface complete all as specified and directed. | 456 | Point | - | - |
| 5 | Material & Labour for point wiring for One light / ceiling fan / exhaust fan / call bell point controlled by one switch, wiring shall consist of 1.5 Sqmm 1100 Volts grade FRLSH insulated, unsheathed, multistranded single core copper conductor cable conforming to IS:694, along with one run of 1.5 Sqmm FRLSH insulated copper conductor cable green in colour for continuous earthing, drawn through and including medium grade rigid PVC conduit conforming to IS:9537 (Pt-III) and its all accessories/junction boxes/ inspection covers etc of suitable size but not less than 20mm(OD), concealed in wall/ floor etc including provision of pressed steel terminal box of thickness not less than 18 SWG / with earth dolly of suitable size concealed in wall and covered with 3 mm thick phenolic laminated hylam sheet fixed with brass/GI screws for mounting switches, sockets, fan regulator, etc. complete all as specified and directed. | 200 | Point | - | - |
| 6 | Material & Labour for point wiring for One 6A socket point controlled by one switch on independent board, wiring shall consist of 1.5 Sqmm 1100 Volts grade FRLSH insulated, unsheathed, multistranded single core copper conductor cable conforming to IS:694, along with one run of 1.5 Sqmm FRLSH insulated copper conductor cable green in colour for continuous earthing, drawn through and including medium grade rigid PVC conduit conforming to IS:9537 (Pt-III) and its all accessories/junction boxes/ inspection covers etc of suitable size but not less than 20mm(OD), concealed in wall/ floor etc including provision of separate pressed steel terminal box of thickness not less than 18 SWG / with earth dolly of suitable size concealed in wall and covered with 3 mm thick phenolic laminated hylam sheet fixed with brass/GI screws for mounting switches, sockets, etc. complete all as specified and directed. | 70 | Point | - | - |
| 7 | Material & Labour for point wiring for One 6A socket point controlled by one switch on same board, wiring shall consist of 1.5 Sqmm 1100 Volts grade FRLSH insulated, unsheathed, multistranded single core copper conductor cable conforming to IS:694, along with one run of 1.5 Sqmm FRLSH insulated copper conductor cable green in colour for continuous earthing, drawn through and including medium grade rigid PVC conduit conforming to IS:9537 (Pt-III) and its all accessories/junction boxes/ inspection covers etc of suitable size but not less than 20mm(OD), concealed in wall/ floor etc. Rate shall be inclusive of loop wiring inside the existing master pressed steel terminal box of thickness not less than 18 SWG sharing the same 3 mm thick phenolic laminated hylam sheet cover, including all hardware and its all accessories complete all as specified and directed. | 70 | Point | - | - |
| 8 | Material & Labour for point wiring for One 16A socket point controlled by one 16A switch on independent board, wiring shall consist of 2.5 Sqmm 1100 Volts grade FRLSH insulated, unsheathed, multistranded single core copper conductor cable conforming to IS:694, along with one run of 2.5 Sqmm FRLSH insulated copper conductor cable green in colour for continuous earthing, drawn through and including medium grade rigid PVC conduit conforming to IS:9537 (Pt-III) and its all accessories/junction boxes/ inspection covers etc of suitable size but not less than 20mm(OD), concealed in wall/ floor etc including provision of separate pressed steel terminal box of thickness not less than 18 SWG / with earth dolly of suitable size concealed in wall and covered with 3 mm thick phenolic laminated hylam sheet fixed with brass/GI screws for mounting switches, sockets, etc. complete all as specified and directed. | 20 | Point | - | - |
| 9 | Material & Labour for point wiring for One 16A socket point controlled by one 16A switch on independent board, wiring shall consist of 4 Sqmm 1100 Volts grade FRLSH insulated, unsheathed, multistranded single core copper conductor cable conforming to IS:694, along with one run of 4 Sqmm FRLSH insulated copper conductor cable green in colour for continuous earthing, drawn through and including medium grade rigid PVC conduit conforming to IS:9537 (Pt-III) and its all accessories/junction boxes/ inspection covers etc of suitable size but not less than 20mm(OD), concealed in wall/ floor etc including provision of separate pressed steel terminal box of thickness not less than 18 SWG / with earth dolly of suitable size concealed in wall and covered with 3 mm thick phenolic laminated hylam sheet fixed with brass/GI screws for mounting switches, sockets, etc. complete all as specified and directed. | 5 | Point | - | - |
| 10 | Material & Labour for point wiring for One 16A socket point controlled by one 16A switch on independent board but just below / above the existing socket points / DBs up to one meter distance in the same vertical plane. Wiring shall consist of 2.5 Sqmm 1100 Volts grade FRLSH insulated, unsheathed, multistranded single core copper conductor cable conforming to IS:694, along with one run of 2.5 Sqmm FRLSH insulated copper conductor cable green in colour for continuous earthing, drawn through and including medium grade rigid PVC conduit conforming to IS:9537 (Pt-III) and its all accessories/junction boxes/ inspection covers etc of suitable size but not less than 20mm(OD), concealed in wall/ floor etc including provision of separate pressed steel terminal box of thickness not less than 18 SWG / with earth dolly of suitable size concealed in wall and covered with 3 mm thick phenolic laminated hylam sheet fixed with brass/GI screws for mounting switches, sockets, etc. complete all as specified and directed. | 3 | Point | - | - |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.67 MB
TenderDocuments.pdf
Tender Documents • 1.09 MB
BOQ_875635.xls
BOQ • 1.27 MB
Corrigendum1.pdf
PDF • 0.32 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .