Tender Value
₹37.6 L
EMD Value
₹37,564
Closing Date
25 Aug 2026, 3:00 pmClosed
Superintending Engineer
O/o Superintending Engineer, Mission bhagiratha circle back side of Zilla prajaparishath office
annual maintenance of 33/11 KV and 11 KV substations with distribution transfomers at various pumping stations under yellore segment in wanaparthy division for period september 2026 till March 2027
726623
J1/tenders/02/2026-27 Dt 17.08.2026
OPEN
Electrical Works
WANAPARTHY, TELANGANA
1 document required · 1 mandatory
₹1,330
₹37,564
13 Sept 2026
18 Aug 2026
19 Aug 2026
Engaging of ITI qualified Electrician with 5 years experince in substations from 01.09.2026 to 31.03.2027 for 33/11KV sub stations and 11KV transformer yards 33/11KV substation at Bhuggapalli Thanda (Sep-2026-Mar-2027)
Engaging of ITI qualified Electrician with 5 years experince from 01.09.2026 to 31.03.2027 for 7 month at Gopalpet, Kanaipally, Srirangapur, Ramanpad, Gopaldinne, Solipur, Sankireddypalli, Gourdevipally
Carryout routine maintenance, servicing and testing of 630A to 3000A HT VCB by cleaning fixed contacts, moving contacts and arcchutes including servicing and putting the VCB in perfect working condition after detting all relay and ON, OFF mechanism etc done with only manufacturing companies / Authorised dealers of respective switch gears For every 3 months
Routine maintenance of transformer in operation covering insulation resistance oil, break down strength. Reconditioning / replacement of silicazel, cleaning of transformer and topping upto oil level if required (extra cost will be paid for oil). 950KVA DTR locations: Kanaipally SI No.72-70, Tejaswani Industries make 630 KVA DTR locations: Gopalpet Sl.No. 02,SSE(Shirdi Sai Electricals Ltd) make. 800KVA DTR locations: Ramanpadu2207932, Toshiba make&,Sl.No. 02, SSE (Shirdi Sai Electricals Ltd)make Sankireddypalli Sl.No. 2207928 Toshiba make 500KVA DTR locations: Ramanpadu Sl.No 1289 ,KRK Power Pvt Ltd make Bhuggapalli Thanda 250 KVA DTR locations: Srirangapur Essenar make,s.No.ET2-2488 160KVA DTR locations: Solipur 315KVA DTR locations:Trinity transformer Pvt Gopaldinne 500KVA DTR locations: KRK Power Pvt Ltd Erragattu PH 250KVA DTR locations: ESENNAR Transformer PvT Ltd Ammapur 800KVA DTR locations:Shankarasamudram ( Kanaipalli Intake Well)
Testing of Transformer oil for dielectric breakdown strength. 950KVA DTR locations: Kanaipally SI No.72-70, Tejaswani Industries make 630 KVA DTR locations: Gopalpet Sl.No. 02,SSE(Shirdi Sai Electricals Ltd) make. 800KVA DTR locations: Ramanpadu2207932, Toshiba make&,Sl.No. 02, SSE (Shirdi Sai Electricals Ltd)make Sankireddypalli Sl.No. 2207928 Toshiba make 500KVA DTR locations: Ramanpadu Sl.No 1289 ,KRK Power Pvt Ltd make Bhuggapalli Thanda 250 KVA DTR locations: Srirangapur Essenar make,s.No.ET2-2488 160KVA DTR locations: Solipur 315KVA DTR locations:Trinity transformer Pvt Gopaldinne 500KVA DTR locations: KRK Power Pvt Ltd Erragattu PH 250KVA DTR locations: ESENNAR Transformer PvT Ltd Ammapur 800KVA DTR locations:Shankarasamudram ( Kanaipalli Intake Well)
Attending day to day emergencies(Sub-station check up & maintenance Day to day Protection related emergency works attending and maintenance works of various 33/11KV Substations including Initial assessing the exact faults in the protective device in the VCBs & other protective devices to take up the further works, Rectification/ Replacement of AC/DC fuses, Selector switches, TnC Switches, Push buttons, Hooters, bells, TBs, Ammeters, voltmeters, MW/ KW meters, MVA/ KVA meters, Indication lamps, MVAR/ KVAR meters, PF meters, Panel type energy meters, Terminals, Trip Coils, Close Coils, Spring Charging motors, Relays, Big Gears,Pinion gears, Small gears, 12 V Batteries, 2V Batteries, 24v Chargers, damaged/ defective wiring, etc , measurement of earth resistance, Breaker Operation time (O-CCO) with Breaker timer kits, checking for continuity/ interconnections between earth pits & equipments with primary injection kits, insulation resistance of CTs, PTs, Breakers with Insulation resistance measurement tester (megger), Ratio of CTs with primary injection kits, Tightening of all connections inside the breaker panel, Control Panel, CR Panel, Control Circuit, Battery chargers, battery connections, PTR marshalling boxes, Wiring of CTs and PTs when defective CTs and PTs replaced with new one, Restoration of PT supply to the panel when it fails, Balancing of capacitor bank when cells failed, Fixing up of desired relay settings for feeder, LV, HV, GC breakers, Checking up of VCB mechanical spring charging problem, Checking up of trip circuit healthy of CBs, AC Supply restoration to the breaker when fails, 220V DC supply extension to the VCBs, 24V DC battery chargers connections extension to the VCB when the existing charger fails, Minor alignment of breaker for CB operations, Snatch gap adjustment of breaker to take CB in to service, Identification and rectification of wiring problem of breaker, DC system, AC system for protective equipment, Rectification of mechanical/ slow closing problem of CB where material is not required for the work, Attending the Minor mechanical problems of CBs (Closing / tripping may be electrical or mechanical), Testing of new VCBs (Primary injection, IR values, DC resistance, etc), attending & rectification of oil leakages problems of CTs & PTs, Oil topup in CTs & PTs wherever required, Replacements of Clamps, jumpers, studs, bush rods, bolts & nuts, gaskets, connections of CTs & PTs and other protection related works entrusted by the concerned Engineer for every month
Testing of static/electro mechanical Relay elements for proper operation including recording of all name plate details of Relays & Circuit Breakers, recording of existing relay settings, testing of each element of relay with calibrated relay test kit, recording of re;ay test results in systematic procedure, adjusting & fixing up of time settings of relays wherever required for proper functioning, fixing up of relay settings & grading as per department requirement, recording of revised relay settings of wherever revised, testing of relays by conducting primary injection to the CTs, verification & correcting of connections from CTs to Relays wherever required for proper functioning, carrying out minor rectifications, Measurement & recording of Insulation Resistance values of Current Transformers & Circuit Breakers & connected equipment with suitable calibrated Insulation Measurement Tester, recording of all test results in a systematic way & submission to the department in five copies, execution of work by qualified & experienced persons with contractor owned/ hired calibrated suitable testing equipment as per standards in presence of the concerned AE/ DEE/ EE by proper advance planning, intimation & coordination with the concerned officials, etc for completion of work within schedule time for proper operation of equipment and the rate is inclusive of testing charges transport, loading, unloading, local movement, hire charges, calibration charges, insurance to the working persons, etc complete.
Testing of IED Relay complete all required elements for proper operation including recording of all name plate details of Relays & Circuit Breakers, recording of existing relay settings, testing of each element of relay with calibrated relay test kit, recording of relay test results in systematic procedure, adjusting & fixing up of time settings of relays wherever required for proper functioning, fixing up of relay settings & grading as per department requirement, recording of revised relay settings of wherever revised, testing of relays by conducting primary injection to the CTs, verification & correcting of connections from CTs to Relays wherever required for proper functioning, carrying out minor rectifications, Measurement & recording of Insulation Resistance values of Current Transformers & Circuit Breakers & connected equipment with suitable calibrated Insulation Measurement Tester, recording of all test results in a systematic way & submission to the department in five copies, execution of work by qualified & experienced persons with contractor owned/ hired calibrated suitable testing equipment as per standards in presence of the concerned AE/ DEE/ EE by proper advance planning, intimation & coordination with the concerned officials, etc for completion of work within schedule time for proper operation of equipment and the rate is inclusive of testing charges transport, loading, unloading, local movement, hire charges, calibration charges, insurance to the working persons, etc complete.
Attending day to day emergency works Day to day Power Transformers related emergency works attending and maintenance works of various 33/11KV Substations including initial identification of the defects of PTR on complaints from field to take up the further works, General Checkup of PTRs for healthiness, Attending of minor Oil Leakage complaints, Toping up of oil to the Main & OLTC conservator tanks, Attending the Low Oil Complaints, etc all complaints, Carrying of periodical maintenance of PTRs, Conducting tests periodically as per the norms, Preventive, Breakdown, Predictive & proactive maintenance of PTRs, Conducting pre-Commissioning & Commissioning tests for new & repaired transformers, Replacement of Oil Seals, Silicagel, breathers, Oil cups, PTR Clamps, WTIs, OTIs, PRVs, MOGs, Terminals, Marshalling boxes, probes, Jumpers, Termination of Cables in marshaling box, etc , Measurement of Insulation resistance, DC Resistance, ratios, voltages, Currents, earth resistance of individual earth pits & combined SS earth mat, etc, Checking up of alarms pertains to OT/WT/OLTC/MOG/Bucholtz, Conducting pre commissioning Tests of PTRs when commissioning at existing substations for every month
Filteration of transformer oil as per ISS specifications filters to die electric strength above 40 KV at site 950KVA DTR locations: Kanaipally SI No.72-70, Tejaswani Industries make for repair at Shed 630 KVA DTR locations: Gopalpet Sl.No. 02,SSE(Shirdi Sai Electricals Ltd) make. 800KVA DTR locations: Ramanpadu2207932, Toshiba make&,Sl.No. 02, SSE (Shirdi Sai Electricals Ltd)make Sankireddypalli Sl.No. 2207928 Toshiba make 500KVA DTR locations: Ramanpadu Sl.No 1289 ,KRK Power Pvt Ltd make Bhuggapalli Thanda 250 KVA DTR locations: Srirangapur Essenar make,s.No.ET2-2488 160KVA DTR locations: Solipur 315KVA DTR locations:Trinity transformer Pvt Gopaldinne 500KVA DTR locations: KRK Power Pvt Ltd Erragattu PH 250KVA DTR locations: ESENNAR Transformer PvT Ltd Ammapur 800KVA DTR locations: Shankarasamudram ( Kanaipalli Intake Well)
Providing Transformer oil tested as per IS-335 - 1972 (per Ltr) 950KVA DTR locations: Kanaipally SI No.72-70, Tejaswani Industries make 630 KVA DTR locations: Gopalpet Sl.No. 02,SSE(Shirdi Sai Electricals Ltd) make. 800KVA DTR locations: Ramanpadu2207932, Toshiba make&,Sl.No. 02, SSE (Shirdi Sai Electricals Ltd)make Sankireddypalli Sl.No. 2207928 Toshiba make 500KVA DTR locations: Ramanpadu Sl.No 1289 ,KRK Power Pvt Ltd make Bhuggapalli Thanda 250 KVA DTR locations: Srirangapur Essenar make,s.No.ET2-2488 160KVA DTR locations: Solipur 315KVA DTR locations:Trinity transformer Pvt Gopaldinne 500KVA DTR locations: KRK Power Pvt Ltd Erragattu PH 250KVA DTR locations: ESENNAR Transformer PvT Ltd Ammapur 800KVA DTR locations: Shankarasamudram ( Kanaipalli Intake Well)
Replacing the breather of the DTR/PTR. 950KVA DTR locations: Kanaipally SI No.72-70, Tejaswani Industries make 630 KVA DTR locations: Gopalpet Sl.No. 02,SSE(Shirdi Sai Electricals Ltd) make. 800KVA DTR locations: Ramanpadu2207932, Toshiba make&,Sl.No. 02, SSE (Shirdi Sai Electricals Ltd)make Sankireddypalli Sl.No. 2207928 Toshiba make 500KVA DTR locations: Ramanpadu Sl.No 1289 ,KRK Power Pvt Ltd make Bhuggapalli Thanda 250 KVA DTR locations: Srirangapur Essenar make,s.No.ET2-2488 160KVA DTR locations: Solipur 315KVA DTR locations:Trinity transformer Pvt Gopaldinne 500KVA DTR locations: KRK Power Pvt Ltd Erragattu PH 250KVA DTR locations: ESENNAR Transformer PvT Ltd Ammapur 800KVA DTR locations:Shankarasamudram ( Kanaipalli Intake Well)
Providing and errecting heat shrinkable indoor termination kit for 11 KV HT XLPE insulated armoured cable 70-95 Sqmm 3 core with necessary materials etc., complete. Makes : Raychem / Transeal / M Seal 950KVA DTR locations: Kanaipally SI No.72-70, Tejaswani Industries make 630 KVA DTR locations: Gopalpet Sl.No. 02,SSE(Shirdi Sai Electricals Ltd) make. 800KVA DTR locations: Ramanpadu2207932, Toshiba make&,Sl.No. 02, SSE (Shirdi Sai Electricals Ltd)make Sankireddypalli Sl.No. 2207928 Toshiba make 500KVA DTR locations: Ramanpadu Sl.No 1289 ,KRK Power Pvt Ltd make Bhuggapalli Thanda 250 KVA DTR locations: Srirangapur Essenar make,s.No.ET2-2488 160KVA DTR locations: Solipur 315KVA DTR locations:Trinity transformer Pvt Gopaldinne 500KVA DTR locations: KRK Power Pvt Ltd Erragattu PH 250KVA DTR locations: ESENNAR Transformer PvT Ltd Ammapur 800KVA DTR locations:Shankarasamudram ( Kanaipalli Intake Well)
Providing and errecting heat shrinkable indoor termination kit for 11 KV HT XLPE insulated armoured cable 120 Sqmm 3 core with necessary materials etc., complete. Makes : Raychem / Transeal / M Seal 950KVA DTR locations: Kanaipally SI No.72-70, Tejaswani Industries make 630 KVA DTR locations: Gopalpet Sl.No. 02,SSE(Shirdi Sai Electricals Ltd) make. 800KVA DTR locations: Ramanpadu2207932, Toshiba make&,Sl.No. 02, SSE (Shirdi Sai Electricals Ltd)make Sankireddypalli Sl.No. 2207928 Toshiba make 500KVA DTR locations: Ramanpadu Sl.No 1289 ,KRK Power Pvt Ltd make Bhuggapalli Thanda 250 KVA DTR locations: Srirangapur Essenar make,s.No.ET2-2488 160KVA DTR locations: Solipur 315KVA DTR locations:Trinity transformer Pvt Gopaldinne 500KVA DTR locations: KRK Power Pvt Ltd Erragattu PH 250KVA DTR locations: ESENNAR Transformer PvT Ltd Ammapur 800KVA DTR locations:Shankarasamudram ( Kanaipalli Intake Well)
Supply and erection of approved make 11 KV outdoor type gang operated Air Break switch of 400 A capacity with 3 post pin type insulator per phase, mounted in Horizantal / Vertical position with necessary channels on cross arms with adequate length of 'C' class GI pipe for operating handle provided with Lock & Key at suitable height from ground level with necessary clamps.
Supply and erection of approved make 11 KV outdoor type gang operated Air Break switch of 200 A capacity with 3 post pin type insulator per phase, mounted in Horizantal / Vertical position with necessary channels on cross arms with adequate length of 'C' class GI pipe for operating handle provided with Lock & Key at suitable height from ground level with necessary clamps. 160KVA DTR locations: Solipr
Supply and erecting porcelain Disc type insulator suitable for 11KV line with suitable hardware on existing cross arms.
Supply and erecting porcelain Pin type insulator suitable for 11KV line with suitable hardware on existing cross arms.
Supply and erecting porcelain Post type insulator suitable for 11KV line with suitable hardware on existing cross arms.
Supply and Run of 100mm x 50mm G.I strip (Cuurrent Carrying Capacity 1380A) including cost of all accessories and labour charges etc., complete. (5.36Kgs/1Mtr)(Data No.28.1.28 )
Providing independent earthing for Important equipment with 100mm dia Heavy gauge C.I ( Cast iron ) pipe with Flange 2.5m long enclosed in C.C/ brick massonry chamber of 450m x 450m x 400mm with R.C.C. Slab cover duly providing staggered holes filling with salt and charcoal from the bottom of the pipe giving earth connection from electrode through flange with all accessories and labour charges complete, as per IS specifications 732/1982 (Part II)
Supply and Transportation of 500 KVA Copper Wound Transformer KVA TRANSFORMER with all test reports. The Transformer shall be designed and manufactured as per IS : 1180 OCTC with level - II with initial filling of oil as per IS 335-1993. The basic details of the Transformer are as under. Makes: Kirloskar / PETE / Esennar /Voltamp / Crompton / ABB / Schneider / SSE ELEC8.19.1 1. Quantity : 12. Rated KVA : ........KVA3. Service & Location: Continuous Outdoor Distribution ransformer 4. Mounting : Plinth. 5. Wound : Copper Double wound 6. Type : Core type oil immersed7. Cooling : ONAN8. Temp Rise : 40⁰C in oil, 45⁰C by resistance9. Vector Group: Dyn 1110. Primary Connection : Delta11. Nominal Voltage / Current : ______12. Highest system Voltage: 12000V13. Primary Frequency :50 HZ +/- 3%14. Number of Phases : 3 15. Primary wires: 316. Secondary connection : Star17. Secondary Volts / Current : 433V18. Secondary phases : 319. Secondary wires 4 20. Taps on primary winding for primary voltage variation : +5% to - 10% in steps of 2.5% of 7 position (6 Steps) 21. Terminal arrangement. a.HV: HT terminal box as per the site condition. b. LV: Cable box suitable to receive ------------Sq.mm XLPE cable 22. LV:One separate terminal for earthing. 23. Total Losses at 50% Loading [Watts] [Max] --- as per IS 24. Total Losses at 100% Loading [Watts] [Max]--- as per IS 25.Percentage Impedance at 75 deg. C at----- as per IS 26. No Load current: Less than 2% of full load current. 27. Standrad Fittings & Accessories.a. Rating and terminal marking plate: One b. Lifting Lugs:Two c. Off-circuit tap switch :One d. Earthing Terminals :Two e. Radiators (Attachable) :Adequate f.Explosion vent with Diaphragm :One g. Conservator with Drain plug:one h.Oil filling hole with cap :One i. Oil level indicator : One j. Dehydrating Silicagel Breather : One k. Terminal Arrangement: HV With Treminal Box l. Terminal Arrangement : LV Cable Box m. Separate Neutral Bushing : One n. Filter valve with blanking plate : One o.Drain cum filter valve with blanking plate : One p. Air release device : One q. Thermometer Pocket : One r. Four :Unidirectional flat rollers s. One :10Cm dial thermometer(Rigid stem type)
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
Volume 1 wnp yards 07 final months.docx
TENDER_DOCUMENT • 0.38 MB
BOQ Wanaparthy yard final 7 months.xls
TENDER_DOCUMENT • 0.56 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .