Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.7 LAccepted-AOC | L1 | Accepted-AOC Being a lowest bidder | |
| 2 | L2₹22.2 L+₹7.3 L (48.9%)Rejected-Finance | L2 | Rejected-Finance Not a lowest bidder. |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
23 Oct 2021, 6:00 pmClosed
GE 861 EWS
GE 861 EWS C/O 56 APO
REPAIR MAINTENANCE OF EXTERNAL WATER SUPPLY DISTRIBUTION SYSTEM AT KHREW AND SHER E SHALI UNDER GE 861 EWS
2021_MES_477707_1
GE 861 EWS-58/2021-2022
Open Tender
Civil Works - Water Works
Item Rate
270 days
GE 861 EWS
AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
GE 861 EWS
₹50,000
Yes
22 Nov 2021
24 Sept 2021
25 Oct 2021
24 Sept 2021
23 Oct 2021
8 Oct 2021
Amount
Excavation in trenches not exceeding 1.5 Mtr wide and not exceeding 1.5 Mtr deep in Hard/Dense soil and getting out for taking down/laying Pipe lines of any description and in any position including forming sides and bottom surface to required level/ gradients complete all as specified and directed.
Returning filling in, excavated soil including spreading, leveling, watering and well ramming in layers of thickness not exc. 25cm in each layer complete all as specified and directed.
Removing excavated surplus soil to a distance not exc. 50 Mtr and depositing the soil where directed at a level not exceeding 1.5 Mtr above the starting point complete all as specified and directed.
Disconnecting and taking up or down old existing GI/CI/DI pipe line and connections of any description/grade and in any position in trenches/under floors/on walls etc including connected fittings/ accessories and fixtures like bib-taps/stop valves etc. all as directed and specified for the following sizes :- (a) 200mm bore
(b) 150 mm bore
(c) 100 mm bore
(d) 80 mm bore
(e) 50 mm bore
(f) 40 mm bore
(g) 25 mm bore
(h) 20 mm bore
Supply, laying, jointing and testing in trenches, galvanized iron water tubing medium grade (ISI marked) including provision of all necessary steel fittings/ accessories complete all as specified and directed for the following sizes :- (a) 150 mm bore
(b) 100 mm bore
(c) 80 mm bore
(d) 50 mm bore
(e) 40 mm bore
(f) 25 mm bore
(g) 20 mm bore
Laying only old steel water tubing and connections of any description/any grade and in any position obtained in serviceable condition from taking down, in new or old position as in trenches with using new fittings i.e. bends/Tee/ sockets/ reducers/elbow etc. including cutting/making new threads at the ends of old pipes for the following size all as specified and directed:- (a) GI/CI tubing 200 mm bore
(b) GI/CI tubing 150 mm bore
(c) GI/CI tubing 100 mm bore
(d) GI/CI tubing 80 mm bore
(e) GI/CI tubing 50 mm bore
(f) GI/CI tubing 40 mm bore
(g) GI/CI tubing25 mm bore
(h) 20 mm bore Note for item No. 19 to 26 (h) The old retrieved steel tubing obtained in serviceable conditions obtained from srl no 04 to 11 shall be re-used under item No 19 to 25 after cutting & removing unserviceable portion and using new fittings like bends/sockets/unions etc for necessary addition/alteration as per site requirement and the rate quoted against this item deemed to include this aspect. (ii) Pipe shall be used after proper cleaning (Internally & externally) as approved by the Engineer-in-Charge.
Supplying ,laying, jointing & testing in trenches cast iron pipes with spigot and socketed ends centrifugally cast (spun cast) class A suitable for run leads joints complete all as specified and directed by Engineer-in-Charge for the following size:- Note :-(i) Earth work, Joints and CI specials/fittings of the pipes shall be measured and paid for separately under appropriate item of Schedule `A'(ii) Joints of the pipes shall be measured and paid for separately under appropriate item of Schedule `A'. (a) 200mm bore
(b) 150mm bore
(c) 100mm bore
(d) 80mm bore
Supplying and fixing in repair cast iron specials / fittings such as bend, tee, socket, collar, reducer, tail pieces etc. suitable for spigot and socketed/flanged end pipe up to 150 mm bore complete all as specified and directed by Engineer-in-Charge.
Supplying and fixing in repair cast iron specials / fittings such as bend, tee, socket, collar, reducer, tail pieces etc. suitable for spigot and socketed/flanged end pipe 200mm to 300 mm bore complete all as specified and directed by Engineer-in-Charge.
Supply, fixing, jointing and testing, ISI Marked, of approved quality, gun metal globe/gate valve with iron wheel head, both ends screwed for iron pipe including taking down of old one complete all as specified and directed for following bore of pipes:- (a) 50mm bore
(b) 40mm bore
(c) 25mm bore
(d) 20mm bore
(e) 15mm bore
Supply, installation, fixing, jointing and testing, ISI Marked, of approved quality, cast iron sluice valve of class PN-1.6 conforming to IS-14846 of 2000 both ends flanged with iron wheel head and stainless steel spindle, long body type, jointed and tested including taking down of old one complete all as specified and directed for following bores :- (a) 200 mm bore
(b) 150 mm bore
(b) 100 mm bore
(d) 80 mm bore Note:- (i) Joints of the sluice valve shall be measured and paid for separately under appropriate item of BOQ. (ii) Sluice valve shall be of make Bir/Upadhayay/Sant as approved by GE
Supply and fixing, ISI Marked, of approved quality, cast iron non return valve, PN 1.6, both ends flanged jointed and tested including taking down of old one complete all as specified and directed for following sizes (Make Bir/Upadhayay/Sant as approved by GE ) (a) 150mm bore
M & L replacement of Bib taps all as specified and directed, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed of following sizes : (a) 15 mm
M&L for rectifying leakage/breakage pipe line including cutting of the existing CI pipe line for and reducing to required length, in position in trenches in any depth /above ground level of size 200mm dia for insertion of collars,tees,bends or other fittings including dewatering etc complete all as specified and directed . Note :-1. CI Special fittings, joints and jointing materials shall be measured and paid separately under respective item of BOQ.2.Contractor to visit the site at main reservoir of capacity 50000 Gln where work is to be executed before quoting his rates
M&L lagging to pipes used in external water supply of plumbing all around with 25mm thick bonded mineral wool pre-formed. SNAPON pipe section of density 144 Kg/Cum conforming to IS-9842 or equivalent and provided chicken wire mesh netting 25gauge 20mm meshing and plaster of Peris 3 to 5 mm thick all around the mesh after breaking old unsv/ broken lagging all as specefied and directed by Engineer in charge for the following pipe lines :- (a) GI tubing 50mm bore
(b) GI tubing 40mm bore
(c) GI tubing 25mm bore
(d) GI tubing 20mm bore
(e) GI tubing 15mm bore
M&L replacement of water pressure gauge of Bourden’s type 150mm dia with pressure range of 0 to 10 Kg/Sqcm on rising main water supply line including fixing arrangement , GI tubing nipple stop cock making holes by drilling and welding of socket complete all as specified.
M&L opening of GI pipe , cutting threading & S&F GI socket union and reducing , Tee, 40x15mm for branch connection including excavation and other related work all as directed.
Description all as per item No-52 above but size 25x15mm
Supply only Calcium based granular disinfectant for water treatment more stable than chlorine gas, and stronger than Bleaching powder and sodium Hypochloride pack of 45 Kg, Plastic drum
S& F in repair brass heavy duty foot valve of size 150 mm complete all as directed by Engr-in-charge.
S& F in repair brass heavy duty foot valve of size 100 mm complete all as directed by Engr-in-charge.
S& F in repair gland packing 12mm dia complete all as directed by Engr-in-charge.
S& F in repair gland packing 6 mm dia complete all as directed by Engr-in-charge.
M&L for scraping removing and cleaning of interior surface of under ground reservoir of capacity 25000 Gallons at 6 mtr under the ground level cleaning with Alum water with brush after removing the mud /silt in side the tank to the satisfaction of Engr-in- charge including white washing to inner surface to tank and writing date of cleaning and capacity to tank with synthetic enamel paint of size 10cm height on tank complete and all as specified.
All as per srl item No. 59 above but capacity 50000 Gallons reservoir complete all as specified and directed.
Dismantling /taking down of existing dosing pump with connecting accessoiries and repair/replacemenwith plastic shaft and impeller all as per existing make and model t of unserviceable/worn out granular chlorination,high pressure,single head,gear motored adjustable dosing pump having out put 0 to 5 ltrs per hour,adjustable high pressure upto 10kg/sqcm with and including level gauge,agitator 120 watt 900RPM,single mounted motor with plastic shaft and impeller complete all as specified and directed by Engineer-in-Charge.
Dismantling the electric motor induction motor assembly of pump set/VT of capacity 20 HP to 100 HP from the foundation after disconnecting the electric connection,carrying the same to workshop,dismantling of electric motor and taking down worn out windings of rotor field coils and excitor coils,rewinding the startor,rotor and excitor gauge,replacement of insulation material,heat varnishing provision of connecting leads and terminal plates etc to make the electric motor fully serviceable,reassembling the motor shifting back to the installation ,assembling the same with engine making electric connections,testing and commissioning complete all as specified and directed by Engineer-in-Charge.
Dismantling the complete pump set of cap 75 to 100 HP from foundation channel after disconnecting all inlet and outlet connections ,carrying the same to workshop,dismantling of pump , cleaning throughly and taking down worn out parts such as Ball bearing,Impeller , rubber coupling, bushes ,brass ring , studs , replacement of the same with new ,lath work of pump shaft , impeller if required , reassembling , commissioning and testing after fix on orignal site for smooth functioning up to the entire satisfaction complete all as specified and directed by Engineer-in-Charge.
FASD starter oil immersed of capacity 100 HP built in over load relay, incl taking down the existing unserviceable starter complete all as specified by Engr-in-charge. Make: Kilburn/ABB/Bharat Cutler Hammer/Bentex
Taking up and down water lubricated deep well vertical turbine pump set of cap 75 HP any make including rachet assay, hollow shaft, motor, discharge head body, column pipe, steel shaft, including spider with bush etc complete all as specified and directed by Engineer-in-charge.
Supply and fixing in repair ball bearing as per existing size for VT motor 60/75 HP. Make SKF/NBC/NSK
Repair/Replacement and AMC for 06 months of RO + UF commercial plant capacity of 250 LPH including Replacement of sediment filter 20 " (Every Month )- 2 Nos , Replacement of chemical for vessels (Once in a 06 months )- 2 Nos , Replacement of RO membrane (Once in a 06 months )-1 Nos , Service will be done every two months or on call, AMC including all Electrical Parts , including warranty/Guarantee of electronic/electrical items such as Motor 1/2 Hp - 1 No, Dozing Pump 1 No, Pressure gauge, UV Lamp, Electronic panel board and rectifying if any leakage/breakage/short-Circuit of vessel, multiport and panel board, panel wires, other spares , Testing complete all as directed for entire satisfaction of the Engr-in charge.Note:Rate of items required to be replacement during servicing /AMC period will be included in the quoted rate by contractor
M/L for flat 3 core copper conductor PVC insulated and PVC sheathed submersible cable of nominal area of conductor 16 sq mm make Havells/HPL/Finolex.
Taking out submersible/VT pump set up to 75 HP of any make from the bore well complete with column pipe and other connected parts and lowering the same after repair/replacement of the defective parts such as pump shaft , impeller, bushes, neck ring bowl of pump , shaft coupling, studs and others as per site requirment complete including testing thereto after re-installation, all as specified and directed by Engr-in-Charge.Make: Kirloskar Note :- All spare parts shall be measured and paid seperately under respective item of BOQ.
Supply only Pump Shaft as per existing make/model NOTE:- Make of existing pump be confirmed from the AGE E/M or visit the site before quoting bids.
Supply only line shaft 5 feet long as per existing make/model
Supply only line shaft 10 feet long as per existing make/model
Supply only line shaft coupling as per existing make/model
Supply only line shaft Sleeve as per existing make/model
Supply only line shaft Bearing as per existing make/model
Supply only Bearing retainer as per existing make/model
Supply only Packing Box bush as per existing make/model
Supply only Lantern Ring as per existing make/model
Supply only Split Packing Gland as per existing make/model
Supply only Gland packing as per existing make/model
Supply only Head Shaft as per existing make/model
M&L in repair union socket for water supply GI of following sizes all as specefied and directed by Engineer in charge :- (a) Union socket 15mm bore
(b) Union socket 20mm bore
(c) Union socket 25mm bore
(d) Union socket40mm bore
(e) Union socket 50mm bore
M&L in repair socket for water supply GI of following sizes all as specefied and directed by Engineer in charge :- (a) Socket 15mm bore
(b) Socket 20mm bore
(c) Socket 25mm bore
(d) Socket40mm bore
(e) Socket 50mm bore
M&L in repair elbow for water supply GI of following sizes all as specefied and directed by Engineer in charge :- (a) Elbow 15mm bore
(b) Elbow 20mm bore
(c) Elbow 25mm bore
(d) Elbow 40mm bore
(e) Elbow 50mm bore
M&L in repair Tee for water supply GI of following sizes all as specefied and directed by Engineer in charge :- (a) Tee 15mm bore
(b) Tee 20mm bore
(c) Tee 25mm bore
M&L in repair Nipple for water supply GI of following sizes all as specefied and directed by Engineer in charge :- (a) Nipple 15mm bore
(b) Nipple 20mm bore
(c) Nipple 25mm bore
M/L for copper conductor PVC insulated multistranded cable of nominal area of conductor 35 sq mm single core complete all as specified.
M&L ladder packing material of 6mm thick all as specified and directed by Engineer in charge.
M & L run lead joint for water supply CI pipe of size 80mm, complete all as specified by Engr-in-charge.
M & L run lead joint for water supply CI pipe of size 100mm, complete all as specified by Engr-in-charge.
M/S MOHAMMAD SHABAN AND CO
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .