| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹40.5 LAccepted-AOC | L1 | Accepted-AOC Contract was awarded to lowest bidder | |
| 2 | L2₹41.9 L+₹1.4 L (3.38%)Rejected-Finance | L2 | Rejected-Finance Not become lowest bidder | |
| 3 | L3₹42.6 L+₹2.0 L (4.89%)Rejected-Finance 1001 1 AB CIVIL LINES JHANSI 284 001 UP | JHANSI | UTTAR PRADESH | 284001 | L3 | Rejected-Finance Not become lowest bidder | |
| 4 | L4₹43.2 L+₹2.6 L (6.36%)Rejected-Finance 01 NEAR GOVERMENT HOSPITAL KOTHI BAZAR ROAD KOTHI SATNA MADHYA PRADESH 485666 | SATNA | MADHYA PRADESH | 485666 | L4 | Rejected-Finance Not become lowest bidder | |
| 5 | L5₹44.0 L+₹3.4 L (8.40%)Rejected-Finance 282 SADAR BAZAR JHANSI 284001 | JHANSI | JHANSI | UTTAR PRADESH | 284001 | L5 | Rejected-Finance Not become lowest bidder |
| Sl No | Description | Qty | Unit | UNIVERSAL ENGG CO L1 | M/S Kumar Contractors L7 | Dubey Construction Company L5 | M/S NASIM AND CO. L3 | VIJAY BUILDERS L6 | classic contriction co. L2 | V K Engineers and Associates L8 | ADARSH ENTERPRISES L4 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Removing existing water proofing treatment by brushing with wire brush, cleaning of terracing by taking down cement concrete, existing plaster lime cova 80 to 100mm thick mud phuska/cement concrete/lime coba etc, cleaning of all foreign material such as fungus mass dust etc, roughing surface of corner to roof by wire brush complete all as specified and directed. | 3,480 | Sqm | 42 ₹1,46,160 Lowest | 80 ₹2,78,400 | 50 ₹1,74,000 | 60 ₹2,08,800 | 55 ₹1,91,400 | 60 ₹2,08,800 | 50 ₹1,74,000 | 50 ₹1,74,000 |
| 2.00 | M&L water proofing treatment to roof slab with APP based modified polymeric membrane centre core 100 microne HMHDPE outer flim 20 micron, five layer polymeric membrane 3mm thick weight not less than 3kg/Sqm with 100mm overlap laid as per manuacturer's instructions complete all as specified and as directed by Engineer-in-Charge with following course of description below:-
(a) 1st coat applying bitumen primer confirming to IS-3384-1965 @ 0.40 Kg/Sqm to be applied on prepared roof surface till the surface is properly impregnated
(b) 2nd coat of bonding material using blown type bitumen conforming to IS-702 of grade 85/25 @ 1.20 Kg/Sqm
(c) 3rd course of laying of APP Based modifiedpolymeric membrane with 100mm overlap in longitudinal direction and 150mm in transverse direction and edges to be taken up to vertical wall of 20cm height inserted into the vertical wall concealed the joints with bitumen sealed. All joints and changes in all direction should be covered with cement mortar (1:3) mixed with SBR latex @ 200ml per bag of cement and cured well before laying the membrane.
Note:- (i) The work shall be executed through authorised applicator of main manufacturer as approved by GE.
(ii) Top layer of Aluminium paint or cement concrete tiles shall be measured and paid under seperate item. | 3,480 | Sqm | 549 ₹19,10,520 | 620 ₹21,57,600 | 600 ₹20,88,000 | 580 ₹20,18,400 | 600 ₹20,88,000 | 520 ₹18,09,600 Lowest | 650 ₹22,62,000 | 585 ₹20,35,800 |
| 3.00 | M&L for Applying a coat of bituminous aluminium paint @ 0.20 Kg/Sqm over APP membrance, complete all as specified and directed | 3,280 | Sqm | 73 ₹2,39,440 | 76 ₹2,49,280 | 60 ₹1,96,800 Lowest | 70 ₹2,29,600 | 75 ₹2,46,000 | 80 ₹2,62,400 | 60 ₹1,96,800 Lowest | 80 ₹2,62,400 |
| 4.00 | M&L for Cement concrete tiles 25cm x 25cm x 20mm thick, machine pressed; set jointed and pointed in neat cement slurry in floors with grey cement on pigment over 15 mm thick screed/ bedding layer in CM (1:6) complete all as specified and as directed. | 200 | Sqm | 660 ₹1,32,000 | 760 ₹1,52,000 | 700 ₹1,40,000 | 750 ₹1,50,000 | 780 ₹1,56,000 | 660 ₹1,32,000 | 610 ₹1,22,000 Lowest | 680 ₹1,36,000 |
| 5.00 | M&L for PCC (1:2:4) type B-1 (using 20mm graded stone aggregate) as in roof kerbs or mud stops round or chamfered on edges complete all as specified and directed. | 120 | Cum | 4,250 ₹5,10,000 | 4,000 ₹4,80,000 | 4,500 ₹5,40,000 | 3,850 ₹4,62,000 | 3,900 ₹4,68,000 | 4,285 ₹5,14,200 | 5,000 ₹6,00,000 | 3,500 ₹4,20,000 Lowest |
| 6.00 | M&L for 10 mm thick rendering in CM (1:4) mixed with water proofing compound @ 0.20 Ltr/bags on roof surface after removing all dust and cleaning the surface with water through jet spray complete all as specified and directed. | 3,280 | Sqm | 158 ₹5,18,240 Lowest | 160 ₹5,24,800 | 182 ₹5,96,960 | 170 ₹5,57,600 | 195 ₹6,39,600 | 196 ₹6,42,880 | 240 ₹7,87,200 | 195 ₹6,39,600 |
| 7.00 | Supply only liquid water proofing compound, mixed in CM as per manufacturer instruction, complete all as specified and directed. Make : Dr Fixit LW or equivalent approved as per list of makes | 40 | Ltr | 80 ₹3,200 Lowest | 100 ₹4,000 | 90 ₹3,600 | 90 ₹3,600 | 120 ₹4,800 | 86 ₹3,440 | 190 ₹7,600 | 120 ₹4,800 |
| 8.00 | S&F of rotational moulded polyethylene cylindrical vertical with closed top water storage tank triple layered WHITE COLOUR 500 Ltr capacity with connecting nipple, hoisted and fixed in position on new or existing foundation and making GI tubing inlet or outlet connection, with and incl disconnecting and dismantling the existing un-serviceable PVC/RCC water tank on top of roof/slab of bldgs, complete all as specified and directed. | 30 | Each | 4,550 ₹1,36,500 | 5,100 ₹1,53,000 | 4,000 ₹1,20,000 Lowest | 4,850 ₹1,45,500 | 4,900 ₹1,47,000 | 4,600 ₹1,38,000 | 4,120 ₹1,23,600 | 5,000 ₹1,50,000 |
| 9.00 | S&F of rotational moulded polyethylene cylindrical vertical with closed top water storage tank triple layered WHITE COLOUR 1000 Ltr capacity with connecting nipple, hoisted and fixed in position on new or existing foundation and making GI tubing inlet or outlet connection, with and incl disconnecting and dismantling the existing un-serviceable PVC/RCC water tank on top of roof/slab of bldgs, complete all as specified and directed. | 5 | Each | 8,940 ₹44,700 | 8,600 ₹43,000 | 9,140 ₹45,700 | 8,650 ₹43,250 | 8,800 ₹44,000 | 9,030 ₹45,150 | 7,400 ₹37,000 Lowest | 9,500 ₹47,500 |
| 10.00 | Disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning etc. and hoisting, reconnecting and re-fixing in position of exc. 250 litres & not exc. 500 litres capacity of tanks,Date of cleaning of tank will be marked on the tank by stencil with synthetic enamaled paint in uniform size, Size of letters & numbers should be 40mm. complete all as specified and directed. | 50 | Each | 200 ₹10,000 | 220 ₹11,000 | 215 ₹10,750 | 250 ₹12,500 | 245 ₹12,250 | 190 ₹9,500 Lowest | 600 ₹30,000 | 400 ₹20,000 |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
18 Apr 2026, 6:00 pmClosed
Maj Rajesh Rathore
Garrison Engineer Jhansi
REPAIRS TO ROOF TREATMENT, SUNKEN FLOOR AND CONNECTED WORKS TO CERTAIN MD/OTM ACCN FOR ZONE A UNDER AGE B/R-II AT GE JHANSI
2026_MES_758235_1
GE/JHA/TOK/125 OF 2025-26
Open Tender
Civil Works
Item Rate
180 days
GE Jhansi
As per NIT and Tender Documents
9 documents required · 9 mandatory
₹500
GE Jhansi
₹90,000
Yes
23 Jun 2026
28 Mar 2026
20 Apr 2026
28 Mar 2026
18 Apr 2026
11 Apr 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| - | Removing existing water proofing treatment by brushing with wire brush, cleaning of terracing by taking down cement concrete, existing plaster lime cova 80 to 100mm thick mud phuska/cement concrete/lime coba etc, cleaning of all foreign material such as fungus mass dust etc, roughing surface of corner to roof by wire brush complete all as specified and directed. | - | Sqm | - | - |
| - | M&L water proofing treatment to roof slab with APP based modified polymeric membrane centre core 100 microne HMHDPE outer flim 20 micron, five layer polymeric membrane 3mm thick weight not less than 3kg/Sqm with 100mm overlap laid as per manuacturer's instructions complete all as specified and as directed by Engineer-in-Charge with following course of description below:-
(a) 1st coat applying bitumen primer confirming to IS-3384-1965 @ 0.40 Kg/Sqm to be applied on prepared roof surface till the surface is properly impregnated
(b) 2nd coat of bonding material using blown type bitumen conforming to IS-702 of grade 85/25 @ 1.20 Kg/Sqm
(c) 3rd course of laying of APP Based modifiedpolymeric membrane with 100mm overlap in longitudinal direction and 150mm in transverse direction and edges to be taken up to vertical wall of 20cm height inserted into the vertical wall concealed the joints with bitumen sealed. All joints and changes in all direction should be covered with cement mortar (1:3) mixed with SBR latex @ 200ml per bag of cement and cured well before laying the membrane.
Note:- (i) The work shall be executed through authorised applicator of main manufacturer as approved by GE.
(ii) Top layer of Aluminium paint or cement concrete tiles shall be measured and paid under seperate item. | - | Sqm | - | - |
| - | M&L for Applying a coat of bituminous aluminium paint @ 0.20 Kg/Sqm over APP membrance, complete all as specified and directed | - | Sqm | - | - |
| - | M&L for Cement concrete tiles 25cm x 25cm x 20mm thick, machine pressed; set jointed and pointed in neat cement slurry in floors with grey cement on pigment over 15 mm thick screed/ bedding layer in CM (1:6) complete all as specified and as directed. | - | Sqm | - | - |
| - | M&L for PCC (1:2:4) type B-1 (using 20mm graded stone aggregate) as in roof kerbs or mud stops round or chamfered on edges complete all as specified and directed. | - | Cum | - | - |
| - | M&L for 10 mm thick rendering in CM (1:4) mixed with water proofing compound @ 0.20 Ltr/bags on roof surface after removing all dust and cleaning the surface with water through jet spray complete all as specified and directed. | - | Sqm | - | - |
| - | Supply only liquid water proofing compound, mixed in CM as per manufacturer instruction, complete all as specified and directed. Make : Dr Fixit LW or equivalent approved as per list of makes | - | Ltr | - | - |
| - | S&F of rotational moulded polyethylene cylindrical vertical with closed top water storage tank triple layered WHITE COLOUR 500 Ltr capacity with connecting nipple, hoisted and fixed in position on new or existing foundation and making GI tubing inlet or outlet connection, with and incl disconnecting and dismantling the existing un-serviceable PVC/RCC water tank on top of roof/slab of bldgs, complete all as specified and directed. | - | Each | - | - |
| - | S&F of rotational moulded polyethylene cylindrical vertical with closed top water storage tank triple layered WHITE COLOUR 1000 Ltr capacity with connecting nipple, hoisted and fixed in position on new or existing foundation and making GI tubing inlet or outlet connection, with and incl disconnecting and dismantling the existing un-serviceable PVC/RCC water tank on top of roof/slab of bldgs, complete all as specified and directed. | - | Each | - | - |
| - | Disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning etc. and hoisting, reconnecting and re-fixing in position of exc. 250 litres & not exc. 500 litres capacity of tanks,Date of cleaning of tank will be marked on the tank by stencil with synthetic enamaled paint in uniform size, Size of letters & numbers should be 40mm. complete all as specified and directed. | - | Each | - | - |
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.16 MB
BOQ_849291.xls
BOQ • 0.56 MB
TenderDocuments125.pdf
Tender Documents • 1.33 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .