| 1 | L1₹1.4 LAccepted-AOC AT PC BIRU PS SAMAL BARRAGE TALCHER ANGUL ODISHA | TALCHER | ANGUL | ODISHA | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹1.6 L+₹15,386.18 (10.9%)Rejected-Finance KHATA NO 77 175 PLOT NO 770 1050 JORAGADIA TALCHER DIST ANGUL ODISHA 759103 | TALCHER | ANGUL | ODISHA | 759103 | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹1.6 L+₹23,219.41 (16.4%)Rejected-Finance | L3 | Rejected-Finance Being L3 | |
| 4 | L4₹1.7 L+₹27,711.15 (19.5%)Rejected-Finance | L4 | Rejected-Finance Being L4 | |
| 5 | L5₹1.7 L+₹32,535.29 (22.9%)Rejected-Finance AT BAGHUABOL PO HATATOTA DIST ANGUL ODISHA 759100 | ANGUL | ANGUL | ODISHA | 759100 | L5 | Rejected-Finance Being L5 |
Tender Value
₹2.9 L
EMD Value
₹3,700
Closing Date
31 Dec 2023, 5:00 pmClosed
STAFF OFFICER (CIVIL), TALCHER AREA
O/O STAFF OFFICER, CIVIL, TALCHER AREA, MCL
Annual maintenance including minor repair of Office and cleaning of Canteen under GM Office, Talcher Area. for a period of one year.
2023_MCL_296589_1
MCL/GM(TA)/SO(C)/ e-Tender/23-24/46 dt 19.12.23
Open Tender
Civil Works - Others
Item Rate
365 days
TALCHER AREA
Please refer Tender documents.
3 documents required · 3 mandatory
₹3,700
Yes
25 Feb 2024
20 Dec 2023
1 Jan 2024
21 Dec 2023
31 Dec 2023
21 Dec 2023
21 Dec 2023 - 24 Dec 2023
Amount
24 mm thick factory made PVC door shutters made of styles and rails of a uPVC hollow section of size 59x24 mm and wall thickness 2 mm (± 0.2 mm) with inbuilt edging on both sides. The styles and rails mitred and joint at the corners by means of M.S. galvanised/ plastic brackets of size 75x220 mm having wall thickness 1.0 mm and stainless steel screws. The styles of the shutter reinforced by inserting galvanised M.S. tube of size 20x20 mm and 1 mm (± 0.1 mm) wall thickness. The lock rail made up of 'H' section, a uPVC hollow section of size 100x24 mm and 2 mm (± 0.2 mm) wall thickness, fixed to the shutter styles by means of plastic/galvanised M.S. 'U' cleats. The shutter frame filled with a uPVC multi-chambered single panel of size not less than 620 mm, having over all thickness of 20 mm and 1 mm (± 0.1 mm) wall thickness. The panels filled vertically and tie bar at two places by inserting horizontally 6 mm galvanised M.S. rod and fastened with nuts and washers, complete as per manufacturer's specification and direction of Engineer-in-charge. (For W.C. and bathroom door shutter).
Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete
Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. Twin rubber stopper
Providing and Fixing 15 mm thick densified tegular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising @ 120 grams per sqm including both side) consisting of main ‘T’ runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross “T” of size 24x28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main’T’ at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross ‘T’ of length 600 mm and size 24 x28 mm made of 0.33 mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to from grid of size 600x600 mm, resting on periphery walls /partitions on a Perimeter wall angle pre-coated steel of size(24x24X3000 mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws @ 230 mm interval and laying 15 mm thick densified edges calicum silicate ceiling tiles of approved texture in the grid, including, cutting/ making opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc., wherever required. Main ‘T’ runners to be suspended from ceiling using G.I. slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size 85 x 30 x 0.8 mm, spaced at 1200 mm centre to centre along main ‘T’, bottom exposed with 24 mm of all Tsections shall be pre-painted with polyster baked paint, for all heights, as per specifications, drawings and as directed by Engineer-in-Charge. Note :- Only calcium silicate false ceiling area will be measured from wall to wall. No deduction shall be made for exposed frames/opening (cut outs) having area less than 0.30 sqm.The calcium silicate ceiling tile shall have NRC value of 0.50 (Minimum), light reflection > 85%, non- combustible as per B.S. 476 part IV, 100% humidity resistance and also having thermal conductivity
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:30 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
Washing utensils, cleaning of tables, chairs, wall tiles, washing of floor, surrounding brooming and drain complete of canteen building of GM office as per instruction of Engineer-In-Charge.
Total impact of GST plus Labour Cess [@ 1 % (BOCW Cess to be deducted from the RA bill as per the value of the work progress)] for the purpose of CTC
PRADEEP KUMAR DASH
M/S. BAJRANGI CONSTRUCTION
MUKESH KUMAR PRADHAN
PRANAYINI MISHRA
BABURAM SETHI
MUKESH KUMAR BHUTIA
CHANDAN KUMAR PRADHAN
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .