Loading…
Loading…
| # | Company | Amount | Status |
|---|---|---|---|
| 1 | ₹4.1 Laccepted-aoc | ₹4.1 L | accepted-aoc |
Tender Value
₹4.8 L
EMD Value
₹12,075
Closing Date
22 Jul 2026, 11:00 pmClosed
Directorate of Municipal Administration
ESHAMMA JE
Installation of Drinking Water pipeline at Ballari Central Jail in ward no.1, Ballari City
DMA/2026-27/WS/WORK_INDENT60372
DMA/2026-27/WS/WORK_INDENT60372
Open
Water supply/sewage lines
Two Tender Document System(Two Cover)
DMA City Corporation Ballari
4 documents required · 4 mandatory
To qualify for award of this contract, each tenderer in its name should have in the last five years i.e. 2021-2022 to 2025-2026 Mandating satisfactory completion as a prime contractor for at least any one water supply work to an extent of 50percent of the cost of the work, for all works costing up to and Rs.100 lakh. Rs.2.42 Lakhs, wotk done certificate should include the tender indent number.
KPWD CONTRACTOR REGISTRATION CERTIFICATE
To qualify for award of this contract, each tenderer in its name should have in the last five years i.e. 2021-2022 to 2025-2026 Achieved in at least two financial years an average annual financial turnover of Rs.4.83 lakhs Certified turnover certificate issued by the Chartered accountant with UDIN Number
The contractor should have liquid assets and or availability of credit facilities of not less than Rs.1.44 lakhs Unconditional Credit line or Letter of credit or Certificates from Banks for meeting the fund requirement etc.,
NOT APPLICABLE
₹500
₹12,075
22 Jul 2026
15 Jul 2026
24 Jul 2026
18 Jul 2026
Installation of Drinking Water pipeline at Ballari Central Jail in ward no.1, Ballari City
Providing, Laying and Fixing of GI pipes conforming to IS 1239:1990 with latest amendments complete with GI fittings (excluding the cost of fittings) with cuts and threads wherever necessary, includin...
Providing wrought mild steel (galvanized) GI collar confirming to IS 1239-II, 1991 with latest amendments if any. For 65 mm dia GI collar:
Supply and delivery at site wrought middle steel (galvanized) GI bend confirming to IS 1239-II, 1991 with latest amendments if any.For 65 mm dia GI BEND
Providing and fixing DI Resilient seated soft sealing SLUICE VALVE of variouis dia. with body bonnet of Ductile Iron (DI) conforming ti IS-1865 with the latest amendments and of grade GGG 40/50, shaft...
Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights...
Earth work excavation for pipeline trenches in all kinds of soils by mechanicalmeans as per drawing and technical specifications, including setting out,construction of shoring, strutting, barricading,...
Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m, and lift upto 1.5 ...
Providing, laying and jointing HDPE pipes of specified grade and
conforming to IS 4984-2016 with latest ammendments and conveying
to work site including loading and unloading at both destinations and
Providing and installation of Class SN8 Double Wall Corrugated HDPE Specials outer wall corrugated and inner wall smooth piping system in accordance with IS 16098 part 2 and conveying to work site and...
Providing and installation of Class SN8 Double Wall Corrugated HDPE Specials outer wall corrugated and inner wall smooth piping system in accordance with IS 16098 part 2 and conveying to work site and...
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
60372 kw1 others.doc
Tender Document • 0.24 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .