Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.6 LAccepted-AOC 3 IBRAHIM ROAD KHIDDERPORE KOLKATA 700023 | KOLKATA | WEST BENGAL | 700023 | L1 | Accepted-AOC LOWEST AND RESONABLE | |
| 2 | L2₹33.5 L+₹1.2 L (3.66%)Rejected-Finance 2 10 PANCHANANTALA ROAD KOLKATA 700 041 | KOLKATA | WEST BENGAL | 700041 | L2 | Rejected-Finance NOT BEING LOWEST BIDDER | |
| 3 | L3₹36.8 L+₹4.5 L (13.8%)Rejected-Finance ABANI APARTMENT 1ST FLOOR 6 2 TALBAGAN ROAD WEST PO NONACHANDANPUKUR BARRACKPORE KOLKATA 700 122 | KOLKATA | 24 PARAGANAS NORTH | WEST BENGAL | 700122 | L3 | Rejected-Finance NOT BEING LOWEST BIDDER | |
| 4 | L4₹37.6 L+₹5.3 L (16.4%)Rejected-Finance 27 WESTERN STREET ROOM NO 307 KOLKATA 700012 WEST BENGAL | KOLKATA | KOLKATA | WEST BENGAL | 700012 | L4 | Rejected-Finance NOT BEING LOWEST BIDDER | |
| 5 | L5₹39.5 L+₹7.2 L (22.3%)Rejected-Finance | L5 | Rejected-Finance NOT BEING LOWEST BIDDER |
Tender Value
₹40.7 L
EMD Value
₹81,320
Closing Date
21 Feb 2022, 6:00 pmClosed
CWE KOLKATA
Headquarters commander Works Engineers Military Engineer Services No 1, National Library Avenue Alipore, Kolkata 700 027
REPAIR / MAINTENANCE E/M INSTALLATIONS INCLUDES TRANSFORMERS, VCBS, VLE SWITCHES, APFC PANELS GOD AND LT PANELS AT HASTINGS, RASPUNJA, SAHAPUR, OD AREA AND BMC UNDER GE(C) KOLKATA
2022_MES_503332_1
8157/E-020/21-22
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE(C) Kolkata
Please refer Tender documents.
4 documents required · 4 mandatory
₹500
Yes
GE(C) KOLKATA
₹81,320
Yes
16 Mar 2022
24 Jan 2022
23 Feb 2022
24 Jan 2022
21 Feb 2022
7 Feb 2022
24 Jan 2022 - 3 Feb 2022
Amount
NOTE :The bidders/contractors are advised to read tender document & all corrigendum/ amendments and General conditions of contracts before entry/quoting the rates.
Disconnecting HT/LT connection of transformer and opening up the top cover of transformer of capacity 100 KVA to 650 KVA for checking the conditions to carryout repairs at site, including draining out oil from the transformer in suitable container (containers to be provided by the contractor) and repair to the transformer with replacement of parts (as required), checking the lead connection from winding to bus rods including necessary soldering/jointing etc and after complete repair refilling the dehydrated oil, replacing perished gasket with new gasket of same size and testing on full load after connecting the HT/LT connections complete all as directed by GE/AGE Notes :(i) Labour component required for the repalcement of unserviceable parts shall be deemed to be included in the unit rate quoted against this item (ii) Major parts as under shall be measured and paid separately under appropriate item of this BOQ (iii) Dehydration/ filtration of transformer oil shall be measured and paid separately under relevant item of this BOQ’ (iv) T&P and minor parts will be arranged by the contractor and the cost thereof shall be deemed to be included in the unit rate quoted against this item (v) Rate deemed to be inclusive of securing the cables on HT/ LT side for tension free at cable entry box.
Supply only LT Bush insulators as per existing size and shape for 100 to 650 KVA capacity transformers complete all as specified and as directed.
Supply only top cover gasket set as per existing size and shape complete for 100 to 650 KVA capacityTransformers complete all as specified and as directed.
Supply only of gasket (set of four) for LT bushing as per existing size & shape complete for 100 to 650 KVA capacity transformers complete all as specified and as directed.
Supply only temperature gauge of range 0 to 200oC for indication of temperature rise in transformer oil for transformers upto 650 KVA capacity.
Supply only LT stud as per existing size and shape for 100 to 630 KVA capacity transformers complete all as specified and as directed.
Labour & equipment for de-hydration and filtration of transformer oil to improve the di-electric strength (not less than 50KV) including recording results complete all as specified and as directed.
Supply only breather including of silica gel as per existing specification in sealed bag for transformer up to 650 KVA capacity complete all as specified and directed.
M & L for preparation of old painted steel or iron surfaces of transformer of any capacity by scrapping with steel wire brush/scrapper emery paper, etc. and applying two coats of synthetic enamel smoke grey paint over a coat of red oxide primer (painting shall be done by spray machine) including writing of SM No, MES No etc. at prominent place/location of transformer capacity 100KVA to 630KVA with black synthetic enamel thick paint in white back ground complete all as specified and directed
Supply only transformer oil ISI marked in sealed containers for transformers oil, confirming to IS-335 with dielectric strength of not less than 40 KV and testing for strength including recording results complete all as specified. Note:- (i) Purchase vouchers alongwith manufacturer's test certificate shall be produced to GE. (ii) Nos of sealed containers shall be recorde in MB Make:- CASTROL/IOCL(SERVO)/HP
Material, Labour in repair of earthing complete with galvanized steel earth plate electrode 600 x 600 x 6mm thick buried directly in ground vertically to a depth not less than 2.25 mtr deep below the normal ground level, connected with and including galvanized earth strip of size 32 x 6mm thick connected to main test point as directed as earthing lead by means of nuts, bolts, washers of galvanized iron protected by 40mm dia (light grade) GI tubing, funnel, wire mesh, 20mm bore GI tubing (medium grade) watering pipe including concrete pit in PCC (1:3:6) type C-1, precast RCC (1:2:4) type B-1 cover slab of size 350 x 350 x 50mm reinforced with 8mm dia TMT bars @15 cm c/c in both ways and 10mm dia MS handle (01 No) of suitable size for lifting of cover slab, charcoal and salt in alternative layers including necessary excavation and earth work in soft/ loose soil all as shown in Electric Plate No. 3 of SSR Part - I and testing on complete all as specified and directed. Notes : (i) The unit rate shall include for GI water pipe, protection pipe, wire mesh, funnel, excavation, RCC pit cover, PCC, test point, earth srip from top of earth plate upto 7.5 metre ground level (ii) PCC pit shall be provided at least 1.5 mtr away from the earth pit and not just on the earth pit and extra cost of additional length of water pipes and fixing junction, elbows etc. shall be deemed to be included in the unit rate.
Supply and fixing of drop out expulsion fuse assembly single pole 25 to 50 Amp capacity, 11000 Volts grade after taking out old unserviceable one complete all as specified and directed.
Material and labour for taking out of burnt primary / secondary copper windings of HT 11 KV transformer and cleaning all the limbs, replacing with the same with fine enamelled bare copper conductor as per relevant BIS of same gauge size, turns and weight and keeping the same into the hot air oven till the moisture evoporates for working complete all as specified and directed. Note: Rates quoted deemed to be inclusive of all Misc items such as cotton tape, warnishing, impregnated paper etc.
All as per item No 14 here-in-before but for LT 11 KV transformer
Material & Labour for off load tap changer switch suitable for transformer capacity 100 to 650 KVA complete all as specified and directed.
Material & Labour for HV bushing with brass terminal with terminal with nuts and washer and sheet gasket suitable for transformer of capacity 100 to 650 KVA complete all as specified and directed.
Supply & fixing gang operated air breaker switch ,triple pole, mechanically operated , mounted on insulators and steel frame with operating mechanism worked from ground level using heavy duty GI pipe, for current rating 200 amps, out door type (confirming to IS specifications) HT 11 Kv , triple pole with fixed contacts of phosphorous and bronze and a set of drop out HT fuse Assembly , Fuse carrier fitting , 9 insulator type mounted on MS channel operating rod with pad lock arrangement including dismantling old unserviceable gang operated Air breaker switch from two pole / four pole structure complete all as specified and as directed. Note: Rates quoted deemed to be inclusive of all equipment such as crane & transported vehicle
Repair and overhauling of 11 / 6.6 KV any capacity VCBs of Receiving/Distribution System with dusting/cleaning by smooth brushing or dry cotton and lubricating of movable mechanism suitably with oil/grease and replacement of unserviceable/burnt out/worn out spare parts with new one as per existing make, duly commissioned in the VCBs at 11 / 6.6 KV Bulk Receiving Centre including necessary inspection, reassembling , testing , re-commissioning, etc complete for smooth functioning of the equipments to ensure desired result including taking down/dismantling of existing unserviceable spares parts of VCB/Capacitor Banks all as directed by Engineer-in-charge. Note:- (i) Labour component required for the replacement of unserviceable parts shall be deemed to be included in the unit rate quoted against this item. (ii) Major parts as under shall be measured and paid separately under appropriate item of this BOQ (iii) T&P and minor parts will be arranged by the contractor and the cost thereof shall be deemed to be included in the unit rate quoted against this item. (iv) Repair, overhauling & testing of VCB shall be carried out by authorized competent persons of OEMs or their accredited / authorised agancies and contractor shall be submitted supporting document of authorized representative of existing VCB to GE, the service charge of OEM shall deem to be included in above quoted rate.
Supply only Motor for SP charging with gear complete all as specified and as directed. Make : As per existing OEM as approved by GE
Supply only of Big & Small gear complete all as specified and as directed.. Make : As per existing OEM as approved by GE
Supply only of Trip & Close Coil 110 VDC or as per existing volt rating complete all as specified and as directed.. Make : As per existing OEM as approved by GE
Supply only of Holding Base from Mould (Epoxy Mould) complete all as specified and as directed.. Make : As per existing OEM as approved by GE
Supply only of ISO Lating Contacts with brass ring complete all as specified and as directed.. Make : As per existing OEM as approved by GE
Supply only of Spout Bushing complete all as specified and as directed. Make : As per existing OEM as approved by GE
Supply only of Vacum Intermpter complete all as specified and as directed.. Make : As per existing OEM as approved by GE
Supply only of Power Pack 110 VAC/ 110 VDC complete all as specified and as directed. Make : As per existing OEM as approved by GE
Supply only of T.N.C. Switch complete all as specified and as directed. Make : As per existing OEM as approved by GE
Supply only of Close, Trip system shaft mechanism complete all as specified and as directed. Make : As per existing OEM as approved by GE
Supply only of Auxiulary Switch 12 Way (6No/6NC) complete all as specified and as directed. Make : As per existing OEM as approved by GE
Supply only of Spare Mechanism with Motor gear complete all as specified and as directed. Make : As per existing OEM as approved by GE
Supply only of CT 50-25/5+5A:15/1+15/5 P10 complete all as specified and as directed. Make : As per existing OEM as approved by GE
Supply only of CT 150-50/5+5A:15/1+15/5 P10 complete all as specified and as directed. Make : As per existing OEM as approved by GE
Supply only of Trivector Meter, 3PH, 3W TVM 110V (L-L) 5A CL0.5S BM RS 485 complete all as specified and directed. Make : L&T, Cat No WR200BB52RS or equivalent Model of AE/ KAYCEE/SECURE METERS/HPL
Supply only of Indicator lamp, LED type of colour red, blue and yellow complete all as specified and directed
Supply & fixing in repair lightening arresters expulsion type complete with all fittings, transmission class, discharge capacity 65 kilo Amp of rating 11 KV complete all as specified and as directed.
Supply and laying of XLPE insulated (Earthed), screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 11000 volts grade, cross sectional area 150 Sq mm, 3 core including taking out old unserviceable cable complete all as specified and as directed.
All as per item No 39 here-in-before but 120 Sqmm, 3 core complete all as specified and directed.
All as per item No 39 here-in-before but 95 Sqmm, 3 core complete all as specified and directed.
All as per item No 39 here-in-before but 70 Sqmm, 3 core complete all as specified and directed.
Supply, jointing and testing of cable jointing kit for 11KV(Earthed) grade cable for indoor termination cold shrink type joint complete with jointing materials and accessories suitable for XLPE armored Aluminium conductor cable of size 150 Sqmm, 3 core, including taking out old unserviceable cable jointing kit complete all as specified and as directed.
Supply, jointing and testing of cable jointing kit for 11KV(Earthed) grade cable for indoor termination cold shrink type joint complete with jointing materials and accessories suitable for XLPE armored Aluminium conductor cable of size 95 to 120 Sqmm, 3 core, including taking out old unserviceable cable jointing kit complete all as specified and as directed.
Supply, jointing and testing of cable jointing kit for 11KV(Earthed) grade cable for indoor termination cold shrink type joint complete with jointing materials and accessories suitable for XLPE armored Aluminium conductor cable of size 95 Sqmm, 3 core, including taking out old unserviceable cable jointing kit complete all as specified and as directed.
Supply, jointing and testing of cable jointing kit for 11KV(Earthed) grade cable for indoor termination cold shrink type joint complete with jointing materials and accessories suitable for XLPE armored Aluminium conductor cable of size 70 Sqmm, 3 core, including taking out old unserviceable cable jointing kit complete all as specified and as directed.
Supply, jointing and testing of cable jointing kit for 11KV(Earthed) grade cable for straight through cold shrink type joint complete with jointing materials and accessories suitable for XLPE armored Aluminium conductor cable of size 120 to 185 Sqmm, 3 core, including taking out old unserviceable cable jointing kit complete all as specified and as directed.
Supply, jointing and testing of cable jointing kit for 11KV(Earthed) grade cable for straight through cold shrink type joint complete with jointing materials and accessories suitable for XLPE armored Aluminium conductor cable of size 70 to 95 Sqmm, 3 core, including taking out old unserviceable cable jointing kit complete all as specified and as directed.
Maintenance and overhauling of 6.6 KV link switch (VLE) 200 Amps rating (of make MEI), by opening out HT cable termination joints, draining out complete oil, opening the top cover, lifting the fuse link carrier alongwith HT fuses, checking of locking clamps system, cleaning all the spares of VLE and reflected any minor adjustment found if necessary during the checking and full cleaning of inside portion of VLE, re-filling of de-hydrated oil upto desired level after re-fixing the fuse link in original position complete all as specified & directed. Note :(i) Spare parts (if required) will be measured and paid separately (ii) New transformer oil (if required for topping up) will be measured and paid separately (iii) Dehydration of existing oil filling be measured and paid separately
Supply only HT fuse link (type KEBXO), of capacity 45 Amps, 12 KV, AC Rating complete all as specified and directed. Make:- GE Controls / English Electric / Jaipuria brothers
Supply only oil level indicator transperent cover for VLE as per existing shape and size complete all as specified and directed.
Supply only gasket suitable for top cover of VLE switch as per existing shape & size complete all as specified and directed.
Supply only gasket suitable for top cover of Tee off switch as per existing shape and size complete all as specified and directed.
Supply & fixing HT barrel fuse 40 Amps 6.6 KV after taking out old Unserviceable one complete all as specified and directed.
Excavating in trenches n. exc 1.5m wide and not e. 1.5m in depth for foundation of poles, laying under ground cables, etc and getting out in soft/loose soil complete as specified and directed.
Excavating in trenches n. exc 1.5m wide and exc. 1.5m and n.exc 3.00m in depth for foundation of poles, laying under ground cables, etc and getting out in soft/loose soil complete as specified and directed.
Returning, filling in, including spreading leveling watering and well ramming in layers not exc 25 cm as in soft / loose soil complete as specified and directed.
Removing excavated material not exc. 50 m and depositing where directed at a level not exc 1.5 m above the starting point in soft / loose soil complete as specified and directed.
Material & Labour for sand cushioning to the full width of trenches for protection of cables using silver sand complete all as specified.
Supply and laying sub class 'B' bricks with width equal to the length of the brick laid dry in trenches for protection of power cable complete all as specified and directed
Supply and laying reinforced precast concrete cable cover, class HV type - 1 flat, size 300mmx l80mm x 40mm complete all as specified and directed.
Material and labour for Galvanised iron tubing, 80mm bore, light grade, with all fittings for passing of cables laid under flor / through roads including fixing of clamps, nut and bolts of suitable size where ever required including taking out old u/s pipe complete all as specified & directed.
All as per item No 71 here-in-before but for 50mm bore Galvanised iron tubing
Supplying, installation and errecting of steel tubuler swaged welded pole complete with MS base plate of 6 mm thick of size 300 mm x 300mm, finial taper plug, pole cap bolts, nuts and washers and screwed, pole made out of ERW MS Tubing confirming to IS-2713 (Part-II) 1980 type 410 SP-55 (11 meters long) HT poles ISI Mark including drilling of holes of required size and for fixing of cross arms, painting with one coat of red oxide primer and two coats of aluminium paint on exposed surfaces and two coats of black bituminous paint for portion embeded in concrete, painting including dismantling and taking out old poles complete all as specified and directed. Note :- Excavation, earth work & concrete shall be measured and paid separately.
Material & Labour for plain cement concrete (1:3:6) type C-2 ( with using 40 mm graded stone aggregate) as in foundation of poles including necessary form work complete all as specifed and directed.
Material & Labour for plain cement concrete (1:2:4) type B-1( with using 20 mm graded stone aggregate) as in coping complete all as speceifed and directed.
Material, Labour for 15mm thick rendering in CM (1:6), finishing the surface even & smooth without using extra cement complete all as speceifed and directed.
Supply & laying in replacement high dielectric strength SMC Chequred plate of size 1 mtr x 1 mtr and thickness 3mm wide with EOP foam and adhesive as per manufacture instructions complete all as specified and directed. Make:- GSCQ -1010-3 of Sintex
Supply & laying in replacement high dielectric strength SMC trench cover of size 1 mtr length x 0.75 mtr width x 12mm thickness suitable for 11 / 6.6 KV complete all as specified and directed. Make:- GSCO101012 of Sintex
Material & Labour for Cross arms, bracings, supports clamps and brackets plates fabricated form structural steel section including nuts, bolts, twin washers, welding bending cold or hot drilling holes for bolts in any shape or size as indicated and directed by Engineer-in-Charge including two coats of aluminium paint over a coat pf red oxide primer including taking down old rusted channels complete all as specified and directed.
Trimming / cutting of tree branches of any girth, touching / obstructing the over head lines of HT / LT Poles of three phase distribution system at places length not less than 2m and not more than 40 Mtr span so as to keep minimum 3.0 mtr clearance all around the lines and poles with due care after taking proper electric shutdown from concern JE including disposal thereof (trimmed branch) to a distance not exceeding 100 m complete all as specified and directed.
Note: Schedule of credit (SCHEDULE OF CREDIT) amount of Rs ________ mentioned on Page No ____ shall be deducted from the total quoted amount of BOQ.
ARATI TRADING CO
Globe Electricals
ELECTRO COMMERCIAL CO
TOTCO
MS AP CONSTRUTION AND CO
INDIA ELECTRICAL EQUIPMENTS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .