Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.7 LAccepted-AOC | L1 | Accepted-AOC Lowest | |
| 2 | L2₹39.4 L+₹93,450 (2.43%)Rejected-Finance NO 9 6 203 1 G2 DURGA BHAVANI NAGAR CHAMPAPET HYDERABAD 500059 | HYDERABAD | TELANGANA | 500059 | L2 | Rejected-Finance Not lowest | |
| 3 | L3₹39.5 L+₹1.0 L (2.73%)Rejected-Finance | L3 | Rejected-Finance Not lowest |
Tender Value
₹44 L
EMD Value
₹88,000
Closing Date
19 Dec 2019, 6:00 pmClosed
GE I R and D Kanchanbagh
GE I R and D Kanchanbagh Kanchanbagh Post Hyderabad 500058
SPECIAL REPAIRS TO BILDING NO.72, VIDEO CONFERENCE HALL AT COMPUTER CENTRE (BLDG NO. 63) AND REPAIRS / REPLACEMENT OF AC SHEETS AND OTHER CERTAIN B/R WORKS INSIDE DRDL AT UNDER AGE B/R-I HYDERABAD
2019_MES_300211_1
GE I KBAGH TOKEN 70 OF 2019 2020
Open Tender
Civil Works
Item Rate
270 days
Hyderabad
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE I R and D Kanchanbagh
₹88,000
Yes
16 Jan 2020
22 Nov 2019
24 Dec 2019
22 Nov 2019
19 Dec 2019
6 Dec 2019
22 Nov 2019 - 28 Nov 2019
Amount
Taking down chowkats or frames (without taking out shutters from frame) area n.exc. 1.5 Sqm each complete all as directed.
Taking down chowkats or frames (without taking out shutters from frame) area exc. 1.5 Sqm and n exc. 4 sqm each complete all as directed.
M&L for rendering 10 mm thick in cement mortar 1:3, as in ceiling finished even & smooth without using extra cement including taking down old existig cement plaster complete all as directed.
Complete removal of existing treatment on surfaces of walls including rubbing the surfaces with sand paper (emery) to achieve uniform surfaces and applying two coats of oil bound distemper over a coat of alkali resistant primer over 2mm thick wall care putty, in two layers of 1mm thick each complete all as directed.
Preparation of newly plastered surfaces of walls and applying two coats of oil bound distemper over a coat of alkali resistant primer over 2mm thick wall care putty in two layers of1mm thick each complete all as directed.
Complete removal of existing treatment on surfaces of ceiling including rubbing the surfaces with sand paper (emery) to achieve uniform surfaces and applying two coats of oil bound distemper over a coat of alkali resistant primer over 2mm thick wall care putty, in two layers of 1mm thick each complete all as directed.
Preparation of newly plastered surfaces of ceiling and applying two coats of oil bound distemper over a coat of alkali resistant primer over 2mm thick wall care putty in two layers of1mm thick each complete all as directed.
M&L for PCC 1:2:4 type Bo using 12.5 (graded aggregate) 25 mm thick as in sub-base finished even and fair including demolition of old existing concrete complete all as directed
M&L 10mm thick light shade vitrified ceramic tiles area of each tile n exc 0.36 Sqm as in floors, set in neat cement slurry and pointed in cloured cement to mactch including 15 mm thick screed bed in CM (1:4) including demolition of old existing any type of tiles of any type along with screed bed complete all as directed.
All as per item No.09 here-in-before but as in vertical surface such as skirting over 10 mm thick backing coat rendering in CM 1:4 including demolition of old existing of tiles of any type along with backing coat complete all as directed.
S & F in repairs Vitreous china, white, urinal, half stall type including providing PVC spreader and fixing plugs, bedding urinal against wall in cement mortar (1:2) securing urinal to plugs with and including 60mm long screws, pointing around urinal back in cement connecting water pipe including PVC 32 mm waste coupling and waste pipe complete all as directed.
S & F in repairs WHB vitreous china, 'Flat back or angle back type', coloured including cutting for & pinning in ends of brackets or existing stand including PVC waste pipe and waste fitting 32mm dia, angle cock complete all as directed.
S&F in repairs PVC (SWR) 75 mm dia floor trap plain with grating including jointing with solvent cement complete all as directed
S&F in repairs PVC (SWR) gully trap 125/110 mm , setting and jointing with solvent cement complete all as directed
S&F in repairs towel rail 600mm long of chromium plated fix with and incl CP plate brass screw and wooden/plasting cleats complete all as specified and as directed.
S&F in repairs Gyp board false ceiling with GI snap grid suspended with 4 mm dia GI wire at 600mm c/c , holding and level clips, Gypsum board of size 600mm X 600mm and 12 mm thick with white paper layer on face as directed and applying two coats of acrylic emulsion over a coat of primer complete all as directed.
S&F in repairs Aluminium anodised, sliding door bolt of size 300mm, with hasp,staple (bolt type) and fixing clips of sheet,cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy complete all as directed.
S&F in repairs door closer hydraulically regulated, aluminium body (Die cast), designation No 2, universal type,suitable for door shutter of weight between 36 to 60 kg complete all as directed.
S&F Factory made solid panel PVC door shutter of 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Paneling of plain colour PVC sheet to be fitted in the M. S. frame welded/sealed to the stiles & rails with suitable PVC sheet beading and joined together with solvent cement, complete all as directed.
S&F factory made solid PVC door frame of size 50mmx47mm made out of 5mm thick plain colour PVC sheet reinforced with MS square tube complete all as directed.
S&F steel ventilator with top hung shutter including hinges steel peg stay complete all as directed.
S&F steel windows with side hung shutters including projecting type hinges with steel handle and steel peg stay with glazing bars welded complete all as directed.
S&F in repairs for Framed work such as grills/gratings etc with ends of bars, shouldered and or riveted or forged into spikes framed guard bars barred iron doors ladders frame work of water tanks and similar work conforming to Fe 290. Gde E-165 complete all as directed.
Supply and fix in repairs venetian blinds, fabric blinds verticl type 100 mm wide strips including necessary fittings approved colour to match existing size and quality including taking down old existing venetion blinds complete all as directed
S & F aluminium powder coated standard aluminium sections in windows/Doors/Partitions including glazing clips, including fabrications and fixing in position complete to receive sheet glass and particle board complete all as directed.
S & F powder coated door shutters aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, neoprene rubber packing, handles- 02No in each shutter, hinges 3 Nos, snap beading, screws, complete all as directed
S & F sheet glass 4.8 mm thick, ordinary qualityarea N exc 1.5 sqm each fixed in windows door's/ partition including rubber beading etc., complete all as directed.
S&F 12mm thick pre laminated particle board, exterior grade, laminated on both sides of decorative choice lamination, as in aluminium partitions to match with the existing colour and finishes etc., complete all as directed.
M & L for PCC (1:3:6) type C-2 (using 40 mm graded stone aggregate) of 75 mm thick as in plinth protection/path finished even and fair including demolition of old existing concrete complete all as directed.
M&L for cement concrete 1:2:4 type 1:2:4 (using 20mm graded stone aggregate) as in padding concrete , coving in vertical junctions, coping and plat form for OH water tanks etc on roof top , including demolition of old existing concrete complete all as directed.
M & L for water proofing treatment on roof slab including cleaning the roof surface with wire brush and using water and applying cement slurry @ 3 kg per Sqm and cement plaster 10mm thick in CM 1:4 mixed with WPC @ 2% by weight of cement as per manufacturer's instructions and applying oil based bitumen primer coat at the rate of 0.30 liters per sqm by forced application method on top of plastered roof surface and applying evenly a tack coat of hot air blown bitumen of grade 85/25 at the rate of 1.2 kg per sqm and applying APP based modified polymeric membrane of minimum weight not less than 3kg/sqm as approved by GE, over the bituminous coated surface with100 mm overlaps and the over lap shall be sealed by flame as per manufacturer's instruction and applying evenly a coat of hot air blown bitumen of grade 85/25 at the rate of 1.2 kg per sqm and applying one coat of aluminium paint @ 100 gm / sqm as per manufacturer's instruction including complete removal of existing treatment and removal of the same to a distance exc 50m and n.exc 250m complete all as directed. Note: Waterproofing compound will be measured and paid separately under relevant item.
Supply only integral water proofing compound Make : Dr FIXIT ,Scott No 1
M&L for Brick work with sub class 'B' old size bricks, straight or curved on plan exceeding 6m mean radius built in cement mortar (1:6) including demolition of old existing brick work complete all as directed.
M/L for Preparation of new steel or iron surfaces of any description not otherwise described over 10cm width or girth and applying two coat of synthetic enamel paint over a coat of red oxide primer complete all as directed.
Preparation of previously treated steel surfaces of any description over 10cm width or girth and applying one coats of synthetic enamel paint, complete all as directed.
M & L for preparation of old painted wooden surfaces of any description, over 10cm width or girth and applying one coats of synthetic enamel paint complete all as directed.
Taking down shutters of any description area exc 1 Sqm and n exc 2 Sqm each complete all as directed.
M&L for 15mm thick rendering in cement motar (1:6) on brick or concrete wall surfaces other than fair faces finished even & smooth without using extra cement including taking down old existing cement plaster complete all as directed.
M&L for Preparation of newly plastered surfaces of walls and applying three coats of white wash complete all as directed
S&F in repairs for wall paneling with aluminium frame section 50 x 25x 0.9 mm thick with Grid of 600 mm x 750 mm fixed to the wall with plumb line and fixing of 18 mm thick Prelaminated HDHMR board (High Density High Moisture resistance) one side decorative laminate & other side white balancing lamination Grade-1 type: II, IS- 14587 marked, All edges lipped with PVC edge binding tape (Matching colour nearest to the Pre-laminated HDHMR) 0.45 mm thick with hot melt adhesive on through feed imported Machine and all the exposed corners fixed Round HDHMR beeding duly polished with complete finish all as directed. Make: ACTION TESA or Techno commercial equivalent approved by GE
S&F of 32 mm thick solid wood Prelaminated HDHMR Flush door both side decorative lamination with 2 mm PVC edge binding, Grade-1, Type-II, IS: 14587 marked, complete all as directed. Make: ACTION TESA or Techno commerical equivalent approved by GE
S&F in repairs for Wooden flooring 12 mm thick with plank size 2172 mm x 243 mm, stellar sound absorption, wear layer category AC5 (Abrasion category 5), installed with Megaloc system and V groove shape, followed all manufacture direction over any type of existing flooring surface complete all as directed. Make:- VISTA or Techno commerical equivalent approved by GE
S&F in repairs for wooden venetian solid/metalic blind with head rail size of 53 mm high and 63 mm wide made of alluminium alloy and covered by two end caps made up of PVC, tilter lock made up of aluminium, Tilting & lift cord 2 mm in dia, braided high strength polyster fiber cord for maximum abrasion resistance, Bass wiid slats 50 mm width and 3 mm thick, ladder tape made of polyster tape size 25mm x 44 mm x 54 mm, ladder button of ABS, Drum and cradle assembly provides bearing support to the tilt rod fixing with manufactures direction complete including dismantling of old existing venetial blinds all as specified and directed. Make:- VISTA or Techno commerical equivalent approved by GE
S&F in repairs Armstrong Mineral fibre acoustical suspended false ceiling with visual V-49 (Micro lock) edge open cell tiles with Armstrong supra fine suspended ceiling system, the tiles should have humidity resistance and size of 600 x 600 x 16 mm with Bio Black coating on the face of the tile , the tile shall be laid on Armstrong Silhouette profile grid system with 15 mm white flanges incorporating a 6 mm central reveal in white/Black colour and with a web height of 45 mm and a load carrying capacity of min 15.68 kg per sqm, Silhoutte, main runners & cross Tees to have mitred ends and birdsmouth notches to provide mitred cruciform junctions. Vertical Hangers made 2.68mm of pre straightened GI wire and installed along with adjustable hook clips of 0.8 mm thick galvanised spring steel for 2.68 mm complete all as directed
S&F Brass 4 levers Mortice lock, vertial type of size 100 mm complete all as directed. Make: Godrej, Link, Sheel.
S&F extruded brass handles of size 150 mm long, fabricated type polished complete all as specified
S&F extruded brass handles of size 100 mm long, fabricated type polished complete all as specified
S&F Butt hinges of size 150 mm cast brass with mild steel hinge bright polished, type b-11 complete all as specified
S&F Brass, sliding door bolt of size 300 mm with sand or die cast brass hasp, staple (bolt type) and fixed bolt with rolled or drawn brass bolts complete all as specified
S&F Hasp and staple of size 125 mm dia, safety type brass with mild steel hinge pin including bolt to hinge plate and fixed with screws complete all as specified
S&F Brass barrel tower bolts of size 150 mm with cast or sheet barrel of extruded section and rolled or cast bolts complete all as specified
S&F Brass barrel tower bolts of size 75 mm with cast or sheet barrel of extruded section and rolled or cast bolts complete all as specified
S&F Pre painted galvalume aluminium zinc coating GI based corrugated /trepezoidal steel sheet 0.50 mm thick of any colour having tensile strength of 550Mpa as in roof covering/cladding to wall fixed with self tapping screws including dismantling of existing asbestos cement (corrugated/semi corrugated ,etc) sheets complete all as directed.
M&L Pre painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550Mpa as in ridges fixed with self tapping screws including dismantling of existing ridge complete all as directed.
M&L for Non skid coloured ceramic tiles 7 mm thick area of each tiles exc 0.06 sqm but n.exc 0.11 sqm as in floor finishes set and jointed in neat cement slurry and pointed in white or coloured cement to match laid on and including 15 mm thick screed bed in cement mortar (1:4) , including dismantling of existing tiles alongwith cement mortar bedding (but not bakcing), complete all as directed.
M & L for coloured glazed ceramic tiles of size 300x200x7mm thick on vertical surfaces such as skirting/dado, jointed in neat cement slurry and pointed in white or coloured cement to match with the colour of tiles laid on and including 10 mm thick backing coat in cement mortar (1:4) as backing coat including dismantling of existing tiles alongwith backing coat cement mortar bedding (but not bakcing), complete all as directed.
M & L for coloured glazed ceramic tiles of size 350x250x7mm /450 x 300 x 7 mm thick on vertical surfaces such as skirting/dado, jointed in neat cement slurry and pointed in white or coloured cement to match with the colour of tiles laid on and including 10 mm thick backing coat in cement mortar (1:4) as backing coat including dismantling of existing tiles alongwith backing coat cement mortar bedding (but not bakcing), complete all as specified and as directed.
M&L for 25 mm thick Paving tiles of size 300X 300mm using white cement and pigments of size with wear resistant coating of approved design laid with cement slurry @ 3Kg/ Sqm over 15mm thick screed bed in cement mortar 1:6 including taking out old unserviceable tiles alongwith screed bed complete all as directed.
S&F in repairs vitreous china squatting pan orrisa pattern size 580x440mm white with integral footrest incl trap pors type, lime concrete bedding etc complete making good to floor to match with existing (excluding flushing cistern and flush pipe), complete all as directed.
S&F in repairs vitreous china white wash down water closet pan, pedestal pattern including fixing bolt, plastic water closet seat and cover with recessed bottom with MS CP hinging device (excluding flushing cistern and flush pipe), complete all as directed .
S&F in repairs PVC valveless, syphonic action type , flushing cistern of capacity 10 liters , low level, white , with inlet, ball valve ,bend float and handle including brackets, complete all as directed .
S&F in repair angle valve, cast copper alloy screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions of 15 mm bore complete all as directed.
S&Fin repairs stop valve of 20 mm Bore (dia), cast copper alloy, screwed down, high pressure, with crutch or butter fly handle screwed both ends for iron pipe or for Union, complete all as directed .
S&F in repairs bib cock cast copper alloy chromium plated, screwed down for size 15mm dia , complete all as directed.
S&F in repairs Pillar taps , cast copper alloy , with capstan heads , chromium plated, screwed down high pressure with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly nuts, screwed for iron pipe of bore 15 mm, complete all as directed.
S&F in repairs PVC connections 15 mm size with PTMT nuts of length 450 mm, complete all as directed.
S&F in repairs grating doom 100mm dia of PTMT (min wt 25 gms,) complete all as directed.
S&F in repairs urinial spreader cast copper alloy of CP any colour for fixing with 15mm bore complete all as directed.
S&F Aluminium anodised barrel tower bolts of extruded section with 125 mm long bolt, complete all as directed..
S/F mild steel butt hinges medium weight cold rolled 100 mm size, complete all as directed.
S&F Aluminium handles cast type, anodised, 150 mm size, complete all as directed.
S&F in repairs Galvanised steel water tubing 15 mm bore (dia) Medium Grade with all fittings , fixed on walls and ceiling or laid in floors as required,complete all as specified and as directed.
S&F in repairs Galvanised steel water tubing 20 mm bore (dia) Medium Grade with all fittings , fixed on walls and ceiling or laid in floors as required,complete all as directed.
S&F in repairs Ball valve PTMT for GI pipe 20 mm bore(dia) (minimum weight 210 Grams), high pressure with epoxy coated aluminium Rod and high density plastic ball, screwed for Iron pipe complete all as directed.
S&F in repairs rotational moulded polyethylene water storage tank 1000 ltrs capacity (cylindrical vertical with closed top) double layeerd hoisted and fixed in position complete all as directed.
Material and labour for point wiring complete with ISI marked 1.5 Sqmm PVC insulated unsheathed multistranded single core cable with copper conductor (FRLS) 1100 volts grade drawn through and including PVC rigid conduit 20 mm or higher dia ISI marked as required at site including conduit accessories such as Junction Boxes, Inspection Covers etc, concealed/surface type on stone/brick masonry walls, roofs, floors etc by means of saddles and clamps etc including sunk type MS terminal boxes fabricated out of 1.60 mm thick MS sunken boxes suitable for modular switches sockets, regulators etc. including providing of 1.5 Sqmm PVC insulated multistranded unsheathed copper conductor as earth continuity conductor and connecting to common earth dolly including taking down all unserviceable point wiring all as specified for and connecting up complete for the following:- Note: Rate include the cost of modular plate & cover of suitable models as required at site
One light/ fan point controlled by one, one way switch/bell push
One 5 Amps 3 pin socket outlet on same board
One 5 Amps 3 pin socket outlet on independent board
All as per item No. 77 here-in-before, but wiring with 2.5 Sqmm for 15 Amps switch socket combination on independent board/two pin earth plug and socket including providing 2.5qmm PVC insulated multi stranded unsheathed copper earth continuity conductor and connected to common earth dolly. Make for Item No: 77 to 78 :- For Copper wire :- Finolex/Havells/Plaza
S & F modular switch single pole, one way 6 Amps one module complete all as directed.
S & F modular socket 6 Amps multipurpose 2 in 1- 2/3 pin combined 2 module complete all as directed.
S & F modular switch one way 16 Amps, one module complete all as directed.
Supply and Fixing socket 6/16 Amps multipurpose 2 in 1 -2/3 combined 2 module complete all as directed.
S & F modular ceiling rose three terminals Poly carbonate isolated body complete all as directed. Make for srl items No. 79 to 83 :- Crabtree/Legrand/Schneider
S&F modular bell push, 6 amps One module complete all as specified and directed.
S&F electric bell/buzzer suitable for working on 230 volts AC single phase complete all as directed.
S&F stepped type fan regularor modular type, 120watts, 2 module complete all as directed
M&L for painting to ceiling fan, wall mounted fan, exhaust fan pedestal/air circulator of any size including the guard/frame by spray painting using DUCO paint of approved colour including preparation of surfaces complete all as directed. Note: Cost of Taking down fan and refixing the same after painting is deemed to be included in the quote rate.
M & L for sub main wiring with two runs of 4.0 sqmm PVC insulated and unsheathed 1100 volts grade, stranded copper conductor ISI marked drawn into & including medium grade PVC conduit 20 mm dia with all fittings and accessories fixed concealed including chase cutting in brick/stone masonry walls for fixing conduit and plastering the external surface to match the same with existing surface and one continuous run of 4.0 sqmm copper conductor PVC insulated (green colour) as earth wire complete all as directed. Note: 3 runs of 4 Sqm and 1 run of PVC conduict measured shall be and paid as one unit length
M & L for sub main wiring with two runs single core 6.0 sqmm PVC insulated and unsheathed 1100 volts grade, stranded copper conductor ISI marked drawn into & including medium grade PVC conduit 25 mm dia with all fittings and accessories fixed concealed including chase cutting in brick/stone masonry walls for fixing conduit and plastering the external surface to match the same with existing surface and one continuous run of 6.0 sqmm copper conductor PVC insulated (green colour) as earth wire complete all as directed. Note: 3 runs of 6 Sqm and 1 run of PVC conduict shall be measured and paid as one unit
Supply, Laying, Test and Commissioning LT UG cable of size 50 sqmm; 3.5 core XLPE insulated, armoured, multistranded, aluminium conductor electric cable of 1100 volts grade laid in ground, through trench/pipes including connecting with aluminium lugs etc and including removing old unserviceable cable complete all as directed.
Excavation in trenches not exc.1.5 Mtr in width and not exceeding 1.5Mtr in depth getting out in hard/dense soil for laying cables complete all as directed
Returning, filling, including spreading, levelling, watering and well ramming in layer not exceeding 25cm thick using soil complete all as directed
Removing excavated surplus soil to a distance not exceeding 50 Mtr and depositing where directed at a level not exceeding 1.5 Mtr above the starting point complete all as directed
Supply and filling natural Dry clean river sand for cushioning to cables in trenches including spreading, levelling, hand punning complete all as directed. Note:- Only punned thickess shall be considered for payment purpose.
Supply and laying well burnt old size brick of as protection to cable in trenches including removing old unserviceable brick complete all as directed
S&F MCB, SP, 240 volts, AC, 'C' curve, 10 KA, 6 amps to 32 amps complete all as directed.
S&F MCB, SPN, 240 volts, AC, 'C' curve type, 10 KA, 32 to 40 amps complete all as directed.
S&F MCCB, 3 Pole, 415 volts, AC, adjustable type, 25 KA, 200 amps complete all as directed. Make for item No. 96 to 98 : L&T/Legrand/Havells
S&F in repairs Security light fitting 20 W IP 66 protection, color temp (Cool White) pressure die cast aluminium body with high power LEDs as light source and transperant diffuser with inbuilt driver including connecting up with three core copper cable complete directed. Make : Havells Cat No. ENDURA PEARL SL20W LED757 SASYTOPC or techno commercially equivalent of Philips/Crompton/ Wipro
Supply & Fix in repairs recessed mounted energy efficient LED luminaire 36W, 840 2x2 direct-indirect soft line designed color temp 6500 K, including constant current electronic driver suitable for false ceiling complete with all accessories prewired and connecting up with three core twister flexible copper conductor cable with suitable size includingremoving unserviceable fittings all specified and directed. Make : Havells cat part No.PLUTO NEO 2X2 PLR 34 W LED 857S or techno commercially equivelent of Philips/Wipro
Supply and fix in repairs indoor industrial batten type energy efficient LED luminaire 18/20W, 230 volts surface/wall mounted LED batten including one no. 18/20W LED polycarbonate tube (single side connection) complete with all accessories prewired and including connecting up with twin core flexible copper conductor cable with suitable size complete as directed. Make : Havells Cat No. of batten REGAL BATTEN T8 UPTO 1X22 W SSB SWH & Cat No. of LED tube TITANIA NEO 1213T8 SSTL 18W LED 865SPC or techno commercially equivalent of Philips/Crompton/Wipro
S&F in repairs Vertical TPN DB load line sheet metal enclosure for DBs (double door type) 6 way incl blanking plate as requiredd with 200 amps rated busbar 240V fixed sunk/flush to the wall including Making good the disturbed surfaces to match with the existing surface complete all as directed. Make : L&T Cat No. DBVTL006DD or techno commercially equivalent of Havells/Legrand
S&F in repairs sheet metal enclosure for DBs (double door type) for MCB SPN/DP as a incommer and MCB - SP as a out going, single pole and neutral 8 way incl blanking plate as reuired with 200 amps rated busbar 240V fixed sunk/flush to the wall or niche complete all as specified and directed. Make : L&T Cat No. DBSPN008DD or techno commercially equivalent of Havells/Legrand
Supply & fix in repairs single pole and neutral sheet metal enclosures with a two pin and earth plug and socket complete including one single pole MCB 20 amp 230V, 50 Hz complete all as directed.
S & F 15mm bore GI protection pipe light grade for protection of GI earth wire for mechanical damage and mounting with MS flat iron clamps, nut, bolts, and washers for fixing on walls/ roof complete all as directed.
S & F earth continuity conductor of size 4mm dia GI earth lead wire complete all as directed.
Earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground vertically to a depth not less than 2.25 m deep below normal ground level with top edge of earth plate, not less than 1.5 m below normal ground level connected to galvanized iron earth lead of size 4.0 mm dia by means of bolts, nuts/check nuts and washers etc of galvanized iron, protected by galvanized iron pipe light grade 15 mm dia upto a length of 7.5 m away from earth electrode and connected to main switch/control board including necessary excavation earth work in any type of soil and PCC 1:3:6 type C1 for earth chamber, 40 mm thick RCC cover slab 1:2:4 type B1 with 8 mm dia TMT Bars at 140 mm cc both ways, GI watering pipe 20 mm dia light grade , funnel, wire mesh, lugs, charcoal and salt etc complete all as shown in Electrical plate No. 3 of SSR Part I and testing complete including removing unserviceable earthing all as specified and directed.
Note for item No 107 :- (i) Earth lead beyond 7.5 mtr from electrode to earth terminal point/main switch & GI pipe light grade 15mm dia for protection against mechanical damage to lead shall be measured separately. (ii) On testing if results fails the earthing will be redone at no extra cost.
Taking down carefully by disconnecting, sealing cable ends of addressable/conventional, heat & smoke detector, manual call point, response indicator etc keeping all lequipments & cables in safe costody at the location. Refixing the manual call point, response indicators, heat & smoke detectors to the same location as installed earlier with the taking down cables using necessary saddles/spares for securing the cables on wall/ceiling surfaces and making the entire system functional including testing & commissioning complete all as directed.
Supply and fixing telephone jack 2 way complete all as directed.
Supply and fixing PVC conduit medium grade of size 25mm dia bore complete all as directed.
Taking down carefully the split AC ( internal and external unit) of any make and capacity by pumping down the refrigerant to external unit including stabilizer from the location and shifting the same to the MES store and re-installing the split AC inner, outer, units and stabilizer at the new location or existing location as directed by the site-in-charge including top up the refrigerant as required at site later on renovation of building complete all as directed. Note : (Job includes necessary core cutting on any type of wall for drawing the suction & discharge lines)
Supply & Fix in repairs recessed mounted energy efficient LED luminaire 36W, 840 direct-indirect soft line designed color temp 6500 K, including constant current electronic driver suitable for false ceiling complete with all accessories prewired and connecting up with three core flexible copper conductor cable with suitable size including removing unserviceable fittings complete all specified and as directed. Make : Havells cat part No.PLUTO NEO 2X2 PLR 34W LED 857S or techno commercially equivelent of Philips/Wipro
Supply and fix in repairs LED down lighter energy efficient LED luminaire15 W ultra sleek recessed down light for low height false ceiling in round profile 230 V, complete with all accessories prewired including connecting up with three core twister flexible copper conductor cable of suitable size including removing unserviceable fittings complete all as directed. Make : Philips Cat No. DN097B LED10S-6500 PSU WH or techno commercially equivalent of Havells/CG
S&F in repairs MCB DP 240 volts, AC, 'C' curve, 10 KA, 40 Amps complete all as directed.
Supply and fixing PVC conduit medium grade of size 25mm dia bore complete all as directed.
Disconnecting and taking down fire alarm system complete with smoke detectors cables, panels, hooters etc from existing the position and refixing the same in its position after renovation of building and testing complete all as directed.
Disconnecting and taking down Audio/Video system complete with speaker, LED TV etc from the existing the position and refixing the same in its position after renovation of building and testing complete all as directed.
M/S GDR CONSTRUCTIONS
Indu Electricals
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .