Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹4.5 LAccepted-Finance | L-1 | Accepted-Finance Admitted | |
| 2 | L-2₹5.5 L+₹98,650 (22.0%)Accepted-Finance | L-2 | Accepted-Finance Admitted | |
| 3 | L-3₹6.8 L+₹2.3 L (52.2%)Accepted-Finance | L-3 | Accepted-Finance Admitted | |
| 4 | L4₹7.9 L+₹3.4 L (75.5%)Accepted-Finance | L4 | Accepted-Finance Admitted |
Tender Value
₹6.8 L
EMD Value
₹7,000
Closing Date
20 May 2021, 4:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Superintending Engineer
Electricity Transmission Circle, Pathrahiya Road, Mirzapur
Shifting, loading, carriage, unloading of 40 MVA, 132/33 KV Transformer including erection, testing, commissioning alongwith the other associated work at 132 KV S/S Kachhawa under ETD-IV, Varanasi
2021_UPTCL_573763_2
Short term T. No. 52/2020-21/ETC/Mzp
Open Tender
Electrical Works
Fixed-rate
30 days
kachhwa
As per tender specification
2 documents required · 2 mandatory
₹826
Executive Engineer, ETD, Mirzapur
₹7,000
28 May 2021
11 May 2021
21 May 2021
11 May 2021
20 May 2021
11 May 2021
180 days
Amount
Following work is to be carried out for erection and commissioning of 40 MVA transformer at 132 KV S/S Kachhwa
Packing of 40 MVA T/F accessories such as HV/LV Bushing, Driving mechanism, Marshaling Box and RTCC etc. for safe transportation in wooden crates.
Shifting of dismantled 40MVA T/F from storage place to Loading place (up to 20 meter Distance) including turning of Tank, if required, including all T&P and worker required to complete the job satisfactorily at 132KV S/S Shahganj, Jaunpur.
Additional Shifting of 40MVA T/F for 20 Meter @ 5 Meter/job including turning at 132KV S/S Shahganj, Jaunpur, if required.
Loading of the 40 MVA T/F main tank, conservator tank, radiator, HV/LV Bushing and its other part along with oil drums on the truck/ trailer safely to avoid any type of damage at 132/33 KV S/S Shahganj Jaunpur.
Transportation of the transformer and other accessories from 132 KV S/S Shahganj Jaunpur to 132 KV S/S Kachhwa (Distance around 130 KM). (Insurance Shall be done by the contractor as per direction of Supervising Engineer which shall be reimbursed as per actual) including all cost of men and T&P.
Unloading of the transformer main tank, conservator tank, radiator, HV/LV Bushing and its other part alongwith oil drums from the truck/trailer safety to avoid any type of damage at 132KV Sub-Station Kachhwa.
Shifting of main tank of 40 MVA T/F from unloading place to Plinth (up to 20 mtr Distance) with the help of rail, pulley device, slippers etc. including turning of tank, if required including all T&P and worker required to complete the job satisfactorily at 132KV Sub-Station Kachhwa.
Complete erection of 40 MVA T/F by erection of radiators, conservator tank all bushing with their turrets, connecting oil pipe, cooling fans, motor drive mechanism with tap changer, RTCC panel, and associated oil pipe line etc. to complete the job satisfactorily, including first filling of oil and topping up of T/F oil in tank, Radiator pipe lines, conservator tank etc. and attending oil leakage, if any and all other associated work for satisfactory completion of work along with arrangement of labour and T&P with operations to complete the job in all respect.
Replacement of all the gaskets excluding the top cover of T/F by providing and fixing of new gaskets as per existing size made of rubberized cork sheet Kotika/Turboze/Nu cork brand grade 07.
Centrifuging of complete 40 MVA T/F oil in T/F & Tank by connecting Centrifuging pipes, circulating the T/F oil through centrifuging machine to be provided by the contractor & taking the insulation resistance, water content (PPM) and BDV value of the OIL periodically till the required value is achieved as per direction of supervising engineers, including all T&P, labour, and centrifuging machine shall be provided by the contractor.
Earthing of erected 40 MVA T/F main tank, marshaling box, OLTC, RTCC, Fan control cubical panel and C&R panel at two point using 75x10/50x6 mm M.S Flat with main Grid & H.V & L.V neutral bushing with already constructed Delta Earthing (M.S Flat shall be provided by the contractor including painting of carthing strip with one coat of red oxide primer and two coat of bus green synthetic enameled paint.
75X10 mm M.S Flat
50X6 mm M.S Fiat
Spray painting of following equipments, panels with one coat of red oxide primer and two coats standard make smoke Gray synthetic enamel paint of 1st quality after proper cleaning of rust, dirty & oily surface with by applying suitable chemical, scratching by emery paper/brush/cloth from all surfaces of transformer, OLTC panel, cooling fans and marshaling box, including ail accessories etc.
Erection of 03 Nos. ALP Structure for 120 KV LA and erection of 120 KV Lightening Arrestor with surge counter including all cost of men, material and T & P.
Erection of 03 Nos. ALP Structure for 30 KV LA and erection of 30 KV Lightening Arrestor with surge counter including all cost of men, material and T & P.
Earthing the above L.As with 75X10 mm M.S Flat connect with already constructed Delta Earthing (M.S Flat shall be provided by the contractor also includes painting of earthing strip with one coat of red oxide primer and two coat of bus green synthetic enameled paint.
New jumpering of T/F HV side with twin panther, 120 KV L.A with single panther & from T/F L.V Bushing to 33 KV C.T & C.T to 33 KV Breaker with twin Moose conductor by way of shifting of conductor from store to site, cutting of suitable size & Jumpering including all cost of men, material and T& P.
Laying & termination of new control cables from RTCC panel to marshaling box/D.M box etc. for 40 MVA T/F no. 2 as per cable schedule and inter-connection with control at marshalling box and OLTC pancl to RTCC panel, fan control cubical to each fan with ferruling and dressing including cost of material like glands etc and T&P
Dismantling of defective contactor (10 no), MCB 4 pole (01 no), overload relay(10 no) and its replacement by new one, complete wiring of control cubical of marshaling box as per drawing for proper operation of cooling fans from Auto/manual mode, replacement of damaged terminal connector, control cables from Bucholz relay, PRV, MOG to marshaling box & its termination for proper protection of transformer.
Rewinding of burnt cooling fans by way of dismantling of damaged cooling fan, rewinding the same with same gauge of copper wire, replacement of defective bearing & reinstallation of cooling fans and its electrical connection for proper operation of cooling fans.
Collection of transformer oil samples (Three samples collected from top, bottom of main tank and OLTC) and their testing from NABL approved lab and submitting test report related to BDV water content and DGA.
M/s Mayur Oil Filtration
Ajanta Engineering works
M/S ACCURATE ENGINEERING
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .