Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹24.3 LAccepted-AOC NEAR PARDEEP MEDICAL HALL DEEP NAGAR JALANDHAR CANTT JALANDHAR PUNJAB 144005 | JALANDHAR | PUNJAB | 144005 | 1 | Accepted-AOC Lowest | |
| 2 | 2₹26.4 L+₹2.1 L (8.51%)Rejected-Finance H NO 40 CHOTTI BARADARI PART I GARHA ROAD NEAR MEDICAL COLLEGE JALANDHAR 144 022 PUNJAB | JALANDHAR | JALANDHAR | PUNJAB | 144022 | 2 | Rejected-Finance Higher | |
| 3 | 3₹27.7 L+₹3.4 L (14.1%)Rejected-Finance | 3 | Rejected-Finance Higher | |
| 4 | 4₹28.6 L+₹4.3 L (17.8%)Rejected-Finance | 4 | Rejected-Finance Higher | |
| 5 | 5₹30.4 L+₹6.1 L (25.2%)Rejected-Finance 7TH MILE UPPER SHILLONG P O NONGLYER SHILLONG MEGHALAYA | EAST KHASI HILLS | MEGHALAYA | 793009 | 5 | Rejected-Finance Higher |
Tender Value
₹38.4 L
EMD Value
₹76,740
Closing Date
7 Sept 2020, 4:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Amritsar
GE Amritsar PIN-143001
PROVN OF GEYSERS, FRESH AIR FAN, SECURITY LIGHS WITH POLE, 03 X WINDOW TYPE AC 1.5 TON AND 06 X DESERT COOLER UNDER GE AMRITSAR
2020_MES_368158_1
GE/ASR-21/2020-21
Open Tender
Civil Works
Item Rate
GE Amritsar
Class D category bi
8 documents required · 8 mandatory
₹500
GE Amritsar
₹76,740
Yes
8 Oct 2020
11 Aug 2020
8 Sept 2020
11 Aug 2020
7 Sept 2020
25 Aug 2020
60 days
Amount
Material and labour for point wiring for one geyser controlled by one 1-way switch complete with 2.5 sqmm (nominal area) FR, PVC insulated, un-sheathed and stranded copper conductor cable ISI marked, in and including PVC concealed conduit ISI marked of size 20 mm dia and 1.5 mm wall thickness and PVC conduit fittings such as tees, bends, elbow, reducers except conduit juuction box (junction box will be of MS) including cutting and chasing and 2.5 Sqmm (nominal area) FR, PVC insulated, un-sheathed and stranded copper conductor cable ISI marked as earth wire, connecting to common earth dolly with thimble, including pressed steel powder coated MS sunken box of suitable size, covered with & including 3 mm thick bakelite, laminated hylem sheet top cover and making good surface as original by plastering and whitewash / colour/ distemper etc complete all as specified (the make of FR wire - Polycab / Havells / RR Kabel)
S & F switch socket combination 2 in 1, 5 pin, 5 and 16 Amp flush type universal complete all as specified and directed . Make - Anchor / Havells / Plaza.
Supply and fix storage water haeater (Geyser) of 25 litre capacity 230V AC, 50HZ having element of 2 KW of COPPER/INCOLOY alloy, Rust proof outer body, high density PUF insulation, BEE 4 star rated and above, inner tank of SS 304 which can sustain pressure of minimum 8 bar working pressure and having multifunction safety valve, making electric and water connection complete all as specified. Make : AO Smith Model No HSE - VAS-X25 or equivalent in Racold / Havells.
Supply and fixing of brass chormium plated angle valve, fancy type of size 15mm dia screwed down for high pressure, complete all as specified and directed. Make - Prayag / Jaquar / Shakti.
Supply and fixing plug top 3 pin 16 Amp including connection with existing cable complete all as specified. Make - Anchor Penta / Havells /Plaza.
Supply and fixing of PVC connection suitable for hot water outlet from the geyser of size 15 mm x 600 mm complete all as specified. Make - Prayag / Shakti
Supply and fixing galvanized iron steel tubing medium grade 15 mm bore with all fitting and fixing to walls, ceiling and laid in floor complete all as specified. Note - Quoted rate will include the cost of making water connection from existing supply line and making good of the wall surface etc all as specified. Note: GI Pipeline will be laid after properly cutting and chiselling of wall with suitable machine to the entrire satisfaction of Engr-in-Charge.
Supply and fixing brass chromium plated fancy type bib tabs of size 15 mm dia bore short body, screwed down for GI pipe or for brass ferrule and fixed complete all as specified. Make : Prayag / Shakti /Jaquar
S & F MCB SP single pole, 240 volts, 32 Ampere, rupturing capacity 10 KA, 'c' curve type complete all as specified and directed. Make - Legrand / Siemens / Schiender.
Dismantling floor or wall tiling including cement mortar bedding, removing rubbish of premises complete all specified and directed
Supply and fixing glaze ceremic colour tile 450 mm x 300 mm x 6 mm / 300 mm x 200 mm x 6 mm thick etc on vertical surfaces such as skirting, dado etc set and jointed in neat cemented slurry and pointed in white cement mixed with pigment to match over and including 10 mm thick rendering plaster in cement morar 1:4 on brick surface complete all as specified and directed.
Material and labour for sub main wiring consisting two single core PVC insulated and unsheathed FR cable with stranded copper conductor, size 2.5 sqmm, earth wire 2.5 sqmm one run of multi stranded copper conductor, drawn into and including concealed non metallic PVC conduit, 2 mm thick, 25 mm dia (external) inclusive of MS junction / terminal boxes and all fittings and accessories including cuttin / chasing in brick / stone masonary and making good the surfaces to match with existing taking down old unserviceable sub main wiring complete all as specified. Make of FR wire :- Polycab / Havells / RR Kabel Note :- Two single core of cable 2.5 Sqmm and one run of 2.5 Sqmm earth wire including PVC conduit shall be measured as 'One Unit'.
S & F distribution board double door made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 43 & IK 09 protection surface mounting SPN 4 way, 240 volts with bus bar rating 200 Amps, dust and vermin proof suitable for incorporation of MCB's and isolators etc complete all as specified. Make : Legrand / Hager / Schneider Elect.
Supply and fix steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-22 (9.0 meter long) complete,including painting of poles all as specified and directed by Engineer in Charge.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 4 core 16 Sqmm complete as per IS 7098 Part I (1988). Make :- Havells/Polycab/RR Kabel.
All as per item ser no 15 above but 3.5 core 25 Sqmm.
Supply and fix in replacement of 90W LED light fitting made of pressure die cast aluminium alloy for housing heat sink for effective thermal management studyness excellent corrosion resistance cable gland is used for maintaining ingressprotection epoxy powder coated grey colour finish after phosphochromate treatment, tempered protective toughened glass, thermal shock and impact resistance fixed to the housing with SS screws. High efficacy long life LED module with the SMD LED package mounted on MCPCB with lumen efficacy of LED >140 lumen/Watt with PC lens to ensure better uniformity of light distribution, ambient temperature 35 degree celcius .and system lumen 9000 for above. Power by built in isolated electronic driver SMPS base constant current supply with lower THD, output open slash short circuit protection , Over voltage protection , Phase to phase protection , surge voltage protection 10 KVA. with IK 07 and IP 66 protection, CCT 5700K CRI more than 70 THD<10%, SPD 10 KVA for internal and external 10 KVA extra should be fixed with fitting, PF> 0.95 IP66 IK07 protection with life of 50000Hrs @ L70 operating temp -10 degree to +50 degree input supply voltage range 140/270V frequency 50/60Hz . Driver safety requirement standard: IS 15885/2/13, driver performance requirement IS 16104. Photobiological safety norms IS 16108. Certification LM 79 for luminar LM 80 for LED. And warranty should be 5 Years on site. Make : Havells/philips/wipro.
Material & labour for earthing complete with galvanised earth plate electrode 600 x 600 x 6 mm thick burried directly in ground (earth pit not less than 2.25 below ground level) with top edge of earth plate not less than 1.5 m below normal ground level, connected to galvanised earth lead wire 4 mm dia by means of nuts, bolts, check nuts & washers of galvanised iron or steel all as shown on electrical plate No 3 of MES schedule 2009, Part-I (specifications) and connected to main switch board / main DB's / earthing test point including all necessary excavation and earth work in any type of soil, adequate quantity of charcoal dust & common salt all arount the earth plate minimum 150 mm in all directions with & including watering pipe 20 mm dia GI medium grade, GI funnel made out of 0.63 mm thick GI sheet, wire gauge, 50 mm thick RCC cover in PCC 1:2:4, type B-1 (using 20 mm graded crushed stone aggregate), duly reinforced with 6 mm dia mild steel round bars @ 150 mm both ways center to center with suitable lifting handle to cover, earth pit of PCC 1:3:6 type C-1 (using 20 mm graded crushed stone aggregate), GI protection pipe light grade 15 mm bore up to 7.5 m length from earth electrode & engraving of earth marking on nearby building with CM 1:4 plate size 200 x 150 x 15 mm & painting of earth result etc. including testing on complete all as specified and directed.
S&F of street light fitting brackets 1.5 meter long made out of galvanized iron pipe of 32/40 mm dia size suitable for LED fittings light grade complete with nut bolts washers,clamps etc inclusive of one primer coat one under coat and one finishing coat of silver paint complete all as specified and directed by Engr-in-Charge.
S&F of Junction Box shall be insulated and made out of Polycarbonate with glass fiber reinforced. The size should be not less then 200 X 160 X 98 in mm cat. Part no KF5255 . The Polycarbonate JB shall be environment friendly, recyclable, UV resistant, halogen & silicon free, anti acid & anti corrosive. The JB shall be rated for Degree of Ingress Protection IP 66 in accordance with IEC 60529. The gasket material shall be Polyurethane and the gasket shall be internally embedded. The JBs shall be complies with requirements of the standards IEC 60998-1, IEC 60998-2-1, IEC 60670 –22 & IEC 60670 – 2-5. The JB color according to RAL 9011. The manufacturer of Junction Box / Enclosure shall submit a copy of IEC Certificate. For better safety the Polycarbonate encl shall be fire retardant & self-extinguishing in accordance with IEC 60 695-2-11, DIN VDE 0304 Part 3, UL Subject 94 for Flammability V-2. It should be tested at Glow Wir test for 960 deg. Cent. The impact strength of polycarbonate enclosures / boards i.e. the Degree of Protection against Mechanical load shall be in accordance with EN 50298-98 for IK 08. 6Amp, MCB should be fixed with Junction box, Made of Hensel/Rittal or equivalent. Manufacturer should submit routine test certificate for CJB/PJB.
M&L PVC insulated FR PVC Sheathed multi stranded copper conductor wire 2.5 sqmm size twin core complete for drawing through pole for making connection to street light fitting provided on poles upto junction box incl thimbles.
Excavation in trenches in any type of soil n.exc. 1.5 mtr wide and n.exc 1.5 mtr in depth all as specified & directed.
Returning, filling in, any type of soil and spreading in layers n. exc 25cm thick each layer including watering & well ramming complete all as specified& directed.
Removal of surplus soil to a distance n.exc 50 mtr & depositing where directed at a level n. exc. 1.5mtr above the starting point complete all as specified & directed.
Excavation for poles in trenches in any type of soil .n exc. 1.5 mtr wide and exc 1.5 mtr in depth all as specified & directed.
M & L PCC 1:4:8 type D-2, using stone aggregate 40mm graded as in sub base for electric poles including necessary form work where required and fair finish to the exposed surfaces all as specified & directed by Engr-in-charge.
All as per srl item No 26 here-in-before but PCC 1:3:6 type C-1 using 20mm graded stone aggregated as in foundation poles
All as per srl item No 26 here-in-before but PCC 1:2:4 type B-1 using 20mm graded stone aggregated as coping of poles
Supply and laying old size as sub class 'B' bricks, laid flat in trenches over the cable along the length of cable and bricks perpendicular to the direction of cable adjacent / abutting each other compete all as specified . and directed by Engr-in-Charge.
M&L for sand cushioning with layer of sand 8 cm thick before laying of cable and 15 cm after lying of cable in trenches complete all as specified & directed. Note : Thickness after punning down shall be measured.
S&F street light distribution outdoor panel with canopy single door vertical type made out of CRCA MS sheet with thickness not less than 3 mm surface with insulated material like polysofer or with epoxy powder coating surface mounting TPN 4 way,415 Volt with copper bus bar rating 200Amps for R,Y,B,N phases dust and vermin proof suitable for incorporation of MCCB and IP43-IK09 profection with and incl 100Amps 16KA 4 Pole MCCB including angle iron support legs and foundation work for the legs (including excavation and doing PCC 1:2:4). Make of MCCB Legrand/Schnedier/Siemens. The size of the panel should not be less than 600mmx400mmx200mm, and height of the panel should be atleast 300mm above ground level. the angle iron for support should be minimum 35 mm x 35mm x 5 mm thick.
S&F galvanised iron pipe of 50mm nominal dia light grade fixed to poles with clamps nuts, bolts washers or laid under road cutting or fixed to wall incl painting two coats of aluminium paint over coat of red oxide paint complete all as sprecified and directed by Engr-in-charge.
Material and labour for point wiring complete with 1.5 sqmm (nominal area) FR, PVC insulated, un-sheathed and stranded copper conductor cable ISI marked, in and including PVC concealed conduit ISI marked of size 20 mm dia and 1.5 mm wall thickness and PVC conduit fittings such as tees, bends, elbow, reducers except conduit juuction box (junction box will be of MS) including cutting and chasing and 1.5 Sqmm (nominal area) FR, PVC insulated, un-sheathed and stranded copper conductor cable ISI marked as earth wire, connecting to common earth dolly with thimble, including pressed steel powder coated MS sunken box of suitable size, covered with & including 3 mm thick bakelite, laminated hylem sheet top cover and making good surface as original by plastering and whitewash / colour/ distemper etc complete all as specified (the make of FR wire - Polycab / Havells / RR Kabel) (a) One light point / fan point controlled by one switch
Supply and fix switch piano one way 5 A, SP, 230 Volts.
Supply and fixing ceiling rose surface bakelite 3 terminals 65 x 32 mm complete all as specified.
Supply and fixing of PVC body fresh air fan (heavy duty) of sweep 250 mm heavy duty complete with self closing louvers, mounted in suitable opening arrangement and suitable for operation on 230 volts single phase, 50 Hz, AC supply with and including two core PVC insulated, PVC sheathed copper conductor flexible cable 24/0.2 mm and making all necessary connection and fixed by using suitable size bolts, nuts and washers and grouted in wall in CM 1:3 compelted all as specified and directed. Make : Havells / Orient / Crompton Greaves Note : The cost of making hole in the exisitng wall / window and making good the distrurbed surface of wall / ceiling etc as original i.e. brick work, plastering, white washing etc is included in the quoted rate and no extra payment will be made to contractor in this effect. Make : Havells / Orient / Crompton Greaves
Supply and fix room window type air conditioner electric driven (single phase), cooling capacity 4500 K Cal per hour ( 1.5 Ton). BEE 3 star rated and above complete all as specified as directed. Make -Voltas / Samsung / LG.
Supply, Installation & testing of voltage stabilizer for automatic operation single phase naturally air cooled indoor type and designed for input variation between 140V to 280V with output voltage stabilized at 230V with accuracy of + 2.5% with time delay system and of caapcity 4KVA complete all asspecified. Make Voltas, V-Guard ( VND 500 ), Microtek
S&F single pole and neutral enclosure 32 A ,230 V with a two pin and earth plug and socket complete with one Single pole MCB 32A compl;ete all as specified and directed. Make Legrand/Siemens/Schiender.
M & L for sub main wiring with PVC insulated, 1100 volts grade single core multistranded copper conductor cable conforming to IS specifications, 2 runs of 4 sqmm including 1 run of 4 sq mm single core multistranded copper conductor, PVC insulated cables as earth continuity conductor drawn through and including one run of 25 mm dia rigid PVC conduit and conduit accessories fixed on wall/ceiling etc., or concealed in wall and connecting to common earth dolly all as specified and directed including taking down all sub main wiring . Make of FR wire; Polycab/Havells/RR Cable,Make of PVC Pipe - Polycab/FInolex/Kalinga premium. Note : 2 Run of 4 sqmm, 1 Run of 4 sq mm and 1 run of PVC conduit will be mesuared as 1 unit.
S & F in repair MCB double pole, 240 volts, 16 Ampere, rupturing capacity 10 KA, ‘C’ curve type complete all as specified and directed. Make Legrand/Schiender/L&T.
Supply and installation evaporative desert coolers (steel body) factory made 22 gauge PGI sheet of size 100x70x60cm appx , front and side panels are made of same gauge with wood wool pads having nominal air flow capacity of 4000 cfm, or nearest size,having exhaust fan motor of capacity 1/5 HP with 18” steel blade size, and submersible pump of capacity 18 Watt , and powder coated complete all as specified and directed.”
M&L for fabrication of mild steel stand made out of MS angle iron and flat grade Fe-290-Gde E-165 of size as directed suitable for positioning the desert cooler including painting with two coat of (black) enameled paint over a coat of red oxide primer and fixing at locations complete all as specified and directed.
UNITED ENGINEERING CORPORATION
Bharat Builder
M/S Vijay Punj Constructions
kapoor and co
ACESOLARR RENEWABLE ENERGY LLP
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .