Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.2 CrAccepted-AOC GORUBANDHA MISSAMARI 784 506 | SONITPUR | ASSAM | 784506 | ₹7.2 Cr | L1 | Accepted-AOC Awarded Contract Bidder |
| 2 | L2₹7.5 Cr+₹31.5 L (4.39%)Rejected-Finance | ₹7.5 Cr+₹31.5 L (4.39%) | L2 | Rejected-Finance Rejected as L2 |
| 3 | Rejected-Technical | - | - | Rejected-Technical As per decision of Bid Evaluation Committee |
Tender Value
₹8.5 Cr
EMD Value
₹16.9 L
Closing Date
10 Jun 2022, 2:00 pmClosed
Chief Engineer,(EAP) PWRD,Assam
O/o The Chief Engineer,(EAP) PWRD,Assam Fatasil Ambari,Guwahati- 781025
APART/NOCP/WAREHOUSES/ K-02 Renovation and Upgradation of Warehousing Facilities under the scheme of APART in existing Warehouse Complex at Maidamgaon (Plot-2) in Kamrup District.
2022_PWRDW_25500_17
CE/APART/58/2022/23
Open Tender
Civil Works - Building
Lump-sum
450 days
Kamrup District.
Please refer Tender documents.
6 documents required · 6 mandatory
₹20,000
₹16.9 L
Yes
O/o The Chief Engineer,(EAP) PWRD,Assam
7 Oct 2022
12 May 2022
10 Jun 2022
12 May 2022
10 Jun 2022
12 May 2022
12 May 2022 - 20 May 2022
20 May 2022
Amount
EARTHWORK Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth, 1.5m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth, lead up to 50m and lift up to 1.5m,as directed by Engineer-in-Charge. All kinds of soil.
DISMANTLING AND DEMOLISHING Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. Nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix) Existing Godown Ground Floor Add extra on above
Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge.
Extra for cutting reinforcement bars manually/ by mechanical means in R.C.C. or R.B. work (Payment shall be made on the cross sectional area of R.C.C. or R.B. work) as per direction of Engineer in-charge.
Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. In cement mortar
Dismantling wood work in frames, trusses, purlins and rafters up to 10 metres span and 5 metres height including stacking the material within 50 metres lead : Of sectional area 40 square centimetres and above
Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of: G.S. Sheet
Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : Of area 3 sq. metres and below
Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : Of area beyond 3 sq. metres
Dismantling C.I. pipes including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means breaking lead caulked joints, melting of lead and making into blocks including stacking of pipes & lead at site within 50 metre lead as per direction of Engineer-in-charge: Above 150 mm dia up to 300 mm dia
RETROFITTING WORKS Chipping and breaking/cutting of loose concrete, mortars etc. using Electrical chipping hammers to the satisfaction of the Engineer-in-charge for successful execution of the subsequent rehabilitation works at all heights with all leads, lifts etc. complete with all tools and machineries required for the job, operator, applicator, labour, scaffolding for staging and supervision etc.
Providing and applying two coats of Nitozinc Primer a two component epoxy zinc rich primer/ Sika Top Armatec-108 or equivalent product on the properly cleaned and prepared steel bars after the required chipping and cleaning of the concrete surface as per the manufacturer’s specifications.
Applying of Bonding Agent Nitobond EP Std. / Sikadur -32 LP or equivalent product on substrate before laying of the Micro Concrete complete (the micro concrete shall be poured within 6 hrs/ 4hrs or as applicable of the application of the Bonding agent).
Providing and placing free flow micro concrete Renderoc RG / Sika Micro-Concrete-2 or equivalent product of after fixing slurry tight shuttering. The micro concrete should be mixed mechanically while maintaining water, powder ratio of 0.16 strictly in accordance with the manufacturer's instructions and as per the direction of the Engineer-in-charge. The micro concrete should develop a compressive strength of 10 N/mm2 within 1 day, 40 N/mm2 within 7 days and 50 N/mm2 within 28 days. The cost is inclusive of materials, transportation, labour, taxes etc. all complete.
Drilling 12mm dia x 100mm hole into the concrete/ Brickwall surface using concrete hammer drill machine. Providing 10mm PGMS nozzles in a grid of 0.25m both and injecting with high strength cementitous grout- Cebex 100 /Sika Intraplast EP or equivalent prodsuct till completion and refusal of grout complete as per manufacturer's specifications. The nozzles are to be sealed off after grouting using Renderoc Plug/Sika -2 mortar or equivalent product injecting with high strength cementitious grout- Cebex 100 /Sika Intraplast EP or equivalent product of Fosroc complete as per the specifications of the manufacturer.
Providing and applying two component epoxy resin based moisture intensive low viscous Sikadur-53 UF for high pressure injection grout with drilling & fixing of nozzle at 0.30 mt centre to centre as per manufacturer specification. The cost is inclusive of material, labour, tools & tackles etc all completes.
Repairing of Cracks masonry/ concrete/ reinforced concrete surface by chiselling out to approximately 20 mm x 20 mm, and should always be undercut to avoid formation of a ‘V’ shape and cut back to a minimum depth of 15 mm and given a good mechanical key to apply Renderoc Plug/Sikadur-31 or equivalent product based per manufacturer's specifications.
Providing and applying Nitobond SBR Latex/ Sika Latex or equivalent priming coat followed by placement of Renderoc S2/Sika Top-122 or equivalent high build Light weight polymer modified mortar to give a composite thickness of 10mm. The Mortar should be mixed mechanically while maintaining water powder ratio strictly in accordance with the manufacturer's instructions and as per the direction of the Engineer-in-charge. The cost is inclusive of materials and application and exclusive of scaffolding.
EARTHWORK Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
ANTI - TERMITE TREATMENT Supplying chemical emulsion in sealed containers including delivery as specified. Chlorpyriphos/ Lindane emulsifiable concentrate of 20%
Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti- termite treatment (excluding the cost of chemical emulsion) : Along external wall where the apron (existing) is not provided using chemical emulsion @ 7.5 litres / sqm of the vertical surface of the substructure to a depth of 300mm including excavation channel along the wall & rodding etc. complete: With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration
Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti- termite treatment (excluding the cost of chemical emulsion) : Treatment of soil under existing floors using chemical emul sion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: With Chlorpyriphos/Lindane E.C. 20% with 1% concentration
Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti- termite treatment (excluding the cost of chemical emulsion) : Treatment of existing masonry using chemical emulsion @ one litre per hole at 300 mm interval including drilling holes at 45 degree and plugging them with cement mortar 1:2 (1 cement : 2 coarse sand) to the full depth of the hole : With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration. a) with aqueous emulsion having concentration 1:19 with chloropirophose solution (tricel or euivalent) and water, i.e. 1% solution.
CONCRETE WORKS: Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level: 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources)
Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand(Zone III) : 4 graded stone aggregate 12.5mm nominal size).
Centering and shuttering including strutting, propping etc. and removal of form work for : Retaining walls, return walls, walls (any thickness) including attached pilasters, buttresses, plinth and string courses fillets, kerbs and steps etc..
REINFORCED CEMENT CONCRETE WORKS Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).
Centering and shuttering including strutting, propping etc. and removal of form for: Lintels, beams, plinth beams, girders, bressumers and cantilevers Upto Plinth Level
Centering and shuttering including strutting, propping etc. and removal of form for: Edges of slabs and breaks in floors and walls Under 20 cm wide
MS Sliding Gate Providing and fixing 1 mm thick M.S. sheet sliding-shutters, with frame and diagonal braces of 40x40x6 mm angle iron, 3 mm M.S. gusset plates at the junctions and corners, 25 mm dia pulley, 40x40x6 mm angle and T- iron guide at the top and bottom respectively, including applying a priming coat of approved steel primer.
Providing and fixing plain bend of required degree. 100 mm dia Sand cast iron S&S pipe as per IS: 1729
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
PLASTERING 12 mm cement plaster finished with a floating coat of neat cement of mix : 1:3 (1 cement: 3 fine sand)
MASONRY WORKS: Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand)
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:4 (1 cement : 4 coarse sand) Ventilator opening at floor level
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. Cement mortar 1:3 (1 cement :3 coarse sand) Nogged wall
FLOORING Dry brick pitching half brick thick including supply of bricks and preparing the surface complete : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Cement plaster skirting up to 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement. 18 mm thick.
Providing Vacuum Dewatered Flooring (VDF) with dewatering of concrete by vaccum pump and sprinkling non-metallic floor hardner @5kg/sqm followed by a coat of cement slurry mixed with Nitobond-SBR latex/ Sika Latex or equivalent priming coat (as per company specifications) over the levelling reinforced cement concrete base 1:1.5:3 to be casted simulteniously including providing expansion treatment with 10mm x 12mm groove @ 5mtr. or equally distributed pattern to be cut and filled with Polysulphide Sealent as grouting compound complete as per specifications and as directed by the Engineer. (RCC base to be measured & paid separately)
Providing, supplying, mixing and champhering the edges along joint of wall/ parapet wall and raft/ roof slab having champhered dimension of 150mm x 150mm with cement sand mortar (prop.1:4) mixed with Master Proof IWP-1 of Choksey Chemicals /Dr. Sealkit No. 1 of (Asian Chemicals)/ RHEOMAC 707 of BASF@ 0.2% by weight of cement over a primer coat on the area to be champhered with a combination of 100% acrylic Polymer Master Crete M-81/Dr. Sealkit Sealcrete (Asian Chemicals)/ RHEOMAC 115 of BASF of Choksey Chemicals and cement in the ratio 1:2 to be applied by brush as specified & directed by the Department complete.
ROLLING SHUTTERS/ WINDOWS & VENTILATORS Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover.
Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS : 15622 (thickness to be specified by the manufacturer) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete.
Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. Glazed Vitrified tiles Matt/Antiskid finish of size Size of Tile 600 x 600 mm
Kota stone slab flooring over 15 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick
Providing, fitting and fixing anodised aluminium sliding windows and ventilators of standard sections without horizontal glazing bars, joints mitred and welded (manufactured to relevant IS specifications) and providing and fixing handles, angle cleat, rubber gasket, roller, bolting device, locking arrangements, screws etc as required complete as specified and directed for all levels. 3 Track sliding window 6mm clear glass
FLOORING/ SKIRTING WORKS 62 mm thick cement concrete flooring with concrete hardener topping, under layer 50 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) and top layer 12mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate, 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacture’s specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete.
Cement plaster skirting up to 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement. 18 mm thick
ROOFING Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineerin- charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : Ridges plain (500 - 600mm).
Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : Barge board (Upto 300 mm).
Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : Crimp curve
FINISHES 12 mm cement plaster of mix : 1:4 (1 cement: 4 fine sand)
15 mm cement plaster on the rough side of single or half brick wall of mix : 1:4 (1 cement: 4 fine sand)
Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers. 12mm plaster: 754.38sqm x 0.012m @ 1.2bag/cum :
Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof Gable end portion
PLASTER OF PARIS & WALL PUTTY Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
WALL PAINTING Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete. On Brick/ concrete work
Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm).
PAINTING ON STEEL AND OTHER METAL SURFACE Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : One or more coats on old work.
Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete. On Steel work
Applying Priming coat With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/steel works
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work.
STEEL WORKS Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete .
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Electric resistance or induction butt welded tubes.
TURBO VENTILATOR Supplying, fitting and fixing in position Wind Turbine Roof turbo-ventilator of Nylon made Typhonic Bearing, double top cap ensured permanent alignment in inverted cap design, corrugated foil framed of aluminium fabrication for wind driven having wind velocity 1600 exhauster of effective throatal Dia 21 inch and overall dia 28 inch having overall height 17 inch as specified and directed by the Engineer.
PLINTH PROTECTION Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation leveling and dressing and finishing the top smooth.
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately). Sal Wood
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
FALSE CEILING Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. 12.5 mm thick square edge PVC Laminated Gypsum Tile of size 595x595 mm, made of Gypsum plasterboard, manufactured from natural gypsum as per IS 2095 part I and laminated with white 0.16mm thick fire retardant PVC film on the face side and 12micron metalized polyester on the back side with all edges sealed with the face side PVC film which goes around and wraps the edges and is bonded to the edges and the back side metalized polyester film so as to make the tile a completely sealed unit.
PAINTING ON WOOD SURFACE Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood)
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture
Providing and fixing water closet squatting pan (Indian type W.C.pan) with 100 mm sand cast Iron P or S trap, 10 litre low level whiteP.V.C. flushing cistern, including flush pipe, with manually controlleddevice (handle lever) conforming to IS : 7231, with all fittings andfixtures complete, including cutting and making good the walls andfloors wherever required:White Vitreous china Orissa pattern W.C. pan of size 580x440 mmwith integral type foot rests
Centering and shuttering including strutting, propping etc. and removal of form work for : Foundation, footings, bases of columns
REINFORCED CEMENT CONCRETE WORKS Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
Suspended floors, roofs, landings, balconies and access platform
Columns, Pillars, Piers, Abutments, Posts and Struts
15 mm cement plaster on the rough side of single or half brick wall of mix : 6 mm cement plaster of mix : 1:3 (1 cement: 3 fine sand)
20 mm cement plaster of mix : 1:4 (1 cement: 4 fine sand)
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 2Nos. 1500Ltrs Tank
Providing, hoisting and fixing above plinth level up to floor five level precast reinforced cement concrete slab, including setting in cement mortar 1:3 (1cement : 3 coarse sand), cost of required centering, shuttering and finishing with neat cement punning on exposed surfaces but, excluding the cost of reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). a) 100mm thick slab
Supplying and fixing C.I. cover with frame for manholes : 560 mm diameter C.I. cover (heavy duty) the weight of the cover to be not less than 108 kg 560 mm diameter C.I. cover (heavy duty) the weight of the cover to be not less than 108 kg SEPTIC TANK
Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap
Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings.
Providing and fixing mirror of superior glass (of approved quality) andof required shape and size with plastic moulded frame of approvedmake and shade with 6 mm thick hard board backing : Rectangular shape 453x357 mm
Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms.
Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 gms
150 mm nominal size square 100 mm diameter of the inner hinged round grating
Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : Supplying, fitting and fixing PVC pipes of 6 Kg/cm2 (Supreme/Prince) or other ISI approved including joining ,fitting and fixing wiyh clamps etc.as necessary complete at all levels including below G.L as directed and specified. In exposed surface or trenches 110mm dia.
Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : Supplying, fitting and fixing PVC pipes of 6 Kg/cm2 (Supreme/Prince) or other ISI approved including joining ,fitting and fixing wiyh clamps etc.as necessary complete at all levels including below G.L as directed and specified. In exposed surface or trenches75mm dia
Supplying, fitting and fixing 87.5 degree PVC bend of (Supreme/Prince) or other ISI approved including joining ,fitting and fixing etc.as necessary complete at all levels including below G.L as directed and specified. In exposed surface or trenches 110mm dia.
Supplying, fitting and fixing 87.5 degree PVC bend of (Supreme/Prince) or other ISI approved including joining ,fitting and fixing etc.as necessary complete at all levels including below G.L as directed and specified. In exposed surface or trenches 75mm dia
Supplying fiting and fixing PVC single tee with door of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. In exposed surface or trenches 110mm dia.
Supplying fiting and fixing PVC reducer of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. In exposed faces or trences 110mm x75mm.
Providing fitting and fixing PVC cowel of ISI make complete as directed and specified. 75mm dia. PVC cowel of ISI make
WATER SUPPLY Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 25 mm nominal dia Pipes
WATER SUPPLY Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 32 mm nominal dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 15 mm nominal dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 20 mm nominal dia Pipes
Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. 15 mm nominal dia Pipes
One urinal basin with 5 litre white P.V.C. automatic flushing cistern
Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : 15 mm nominal dia Pipes
RAIN PIPES & EXTERNAL WORKS Providing and fixing soil, waste and vent pipes : 100 mm dia Sand cast iron S&S pipe as per IS: 1729
Providing and filling the joints with spun yarn, cement slurry and cement mortar 1:2 ( 1 cement : 2 fine sand) in S.C.I./ C.I. Pipes : 100 mm dia pipe
Providing and fixing M.S. holder-bat clamps of approved design to Sand Cast iron/cast iron (spun) pipe embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including cost of cutting holes and making good the walls etc. : 100 mm dia pipe
Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete. 100 mm dia Sand cast iron S&S pipe as per IS: 1729
Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: Inside dimensions 455x610 mm and 45 cm deep for single pipe line : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
WIRING IN STEEL AND PVC CONDUIT Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group A
WIRING IN STEEL AND PVC CONDUIT Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group B
WIRING IN STEEL AND PVC CONDUIT Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single 2 x 1.5 Sq.mm + 1 x 1.5 Sq.mm earth wire
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 3 x 1.5 sq. mm
Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required. Above 6.5 metre and upto 8.0 metre
Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enamelled white on both sides, and with inscription in single red colour on front side as required.
Supplying and fixing following piano type switch and socket on the existing switch box/ cover including connections etc. as required as directed. 5/6 amps switch for light power point as directed.
Supplying and fixing following piano type switch and socket on the existing switch box/ cover including connections etc. as required as directed. 3 pin 5/6 A socket outlet SUB MAIN WIRING FROM SPN DB TO SB
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required ( from SPN DB to Switch boards ) 2 x 2.5 Sq.mm + 1 x 2.5 Sq.mm earth wire
SUB POWER DISBTIBUTION BOARD FOR GF Supplying and fixing following way, horizontal type single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (but without MCB / RCCB and incomer) as required.- for each floor power distribution for rooms. 16 - way , Double door
SUB POWER DISBTIBUTION BOARD FOR GF Supplying and fixing following way, horizontal type single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (but without MCB / RCCB and incomer) as required.- for each floor power distribution for rooms. SUB POWER DISBTIBUTION BOARD FOR GF Supplying and fixing following way, horizontal type single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (but without MCB / RCCB and incomer) as required.- for each floor power distribution for rooms. SUB POWER DISBTIBUTION BOARD FOR GF Supplying and fixing following way, horizontal type single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (but without MCB / RCCB and incomer) as required.- for each floor power distribution for rooms. 12 - way , Double door
Supplying and fixing 5 amps to 32 amps rating, 240 volts, 10 KA 'C' series, miniature circuit breaker suitable for lighting and other loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Supplying and fixing 5 amps to 32 amps rating, 240 volts, 10 KA 'C' series, miniature circuit breaker suitable for lighting and other loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
Supplying and fixing 5 amps to 32 amps rating, 240 volts, 10 KA 'C' series, miniature circuit breaker suitable for lighting and other loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole and neutral (16 KA)
Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 25 A
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
LIGHTS FITTINGS Installation, testing and commissioning of prewired, flourescent fittings / all type of LED indoor ceiling fittings , complete with all accessories and tube etc. directly on ceiling/wall/ False ceiling, including connections with 1.5 sq.mm. PVC insulated, copper conductor, single core cable etc. as required.
Supplying of following LED lighting fixtures complete with Drive and Lamps with reflector/cover etc. complete as required:- Make : Sisk / CGL/ Havells/ Surya or Panasonic as approved 1 x 20 W LED 6500K retrofitting polycarbinateT8 tube with in built driver and heat sink double sided connection with compact commercial batten suitable for T8 LED tube Make ;CGL Cat Ref. LT820865 and for batten unilite DMLN1LT8-16 or equivalent Siska or Havells , phillips, bajaj as approved. for small class room lighting
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
EARTHING Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia cover plate having locking arangement and watereing pipe with charcoal / coke andsalt as required for out door lighting system & indoor DBs. One for VTPN and 1 for washr room and 1 for cofee house .
Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
Providing and fixing of G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run)
Providing and fixing earth bus bar joint made of 20mmx3mm thick 125 mm long with 6 nos. G.I bolts , nuts, chuck nut and spring washers etc. complete as requried
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioC70:C80ning, protective covering and refilling the trench etc as required. Up to 35 sq. mm
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on surface of building walls addirected Upto 35 sq. mm (clamped with 1mm thick saddle)
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Upto 35sq. mm
Supply and making cable end termination with brass compression glands and crimped aluminium lugs following sizes of PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade of the following sizes as required. 3C X 6 sq. mm (19mm)
UNDER GROUND CABLE WORKS Supply of following sizes of 1.1 KV grade single core/multicore aluminium conductor XLPE insulated and PVC sheathed armoured / unarmoured cable conforming to IS 1554 (Part-I) 1988.. Make ; RR Kable, Havells, Polycab, KEI Or equivalent as approved 3 Core, 6 sq.mm. XLPE ARMOURED Aluminium Cable. Form transformer to MDB
Construction of 400mm x 400mm x 400mm masonry manhole with air tight C.I. Cover requires for earthing point to cover.
Supplying and embedding following G.I pipe of medium class for cable entry / road crossing of cable etc. including bending the pipe as required shape as required. b) 40 mm dia
Fire Extenguisher Supply and istallation of 4.5 Kg, Mild steel ABC, A class powder/ CO2 type fire extenguisher
Point wiring - Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. Group B
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 2 way 5/6 A switch
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required
Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. 100 mm X 100 mm X 60 mm deep
Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. 150 mm X 75 mm X 60 mm deep
Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. 5/6amp switch
Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. 3 pin 5/6 A socket outlet
Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. 15/16 A switch
Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. 6 pin 15/16 A socket outlet
Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. Bell push
Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required.
Supplying of following LED lighting fixtures complete with Drive and Lamps with reflector/cover etc. complete as required:- Make : Sisk / CGL/ Havells/ Surya or Panasonic as approved 1 x 20 W LED 6500K retrofitting polycarbinateT8 tube with in built driver and heat sink double sided connection with compact commercial batten suitable for T8 LED tube Make ;CGL Cat Ref. LT820865 and for batten unilite DMLN1LT8-16 or equivalent Siska or Havells , phillips, bajaj as approved. for small class room lighting
Supply and installation of angle batten holder with 12W LED NW lamp .
Supply and Installation of 1200 mm sweep white summer cool ceiling fan. Make ; Oirent summer cool or equivalent Havells or CGL make as approved.
SUB POWER DISBTIBUTION BOARD Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 6 way (4 + 18), Double door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Triple pole for TPN DB incomming
Installation of exhaust fan upto 450 mm sweep in the existing opening, including making the hole to suit the size of the above fan, making good the damage, connections, testing, commissioning etc. as required.
Supply of 150mm high spped exhaust fan having automatinc lovour shutter . Make ; Oirent Ventilator HS or equivalent Havells, CGL or Panasomic make as approved. For Toilets
Supply of 300 mm high spped exhaust fan . Make ; Oirent or equivalent Havells, CGL or Panasomic make as approved. For Kitchens
Providing and fixing of G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run)
UNDER GROUND CABLE WORKS Supply of following sizes of 1.1 KV grade single core/multicore aluminium conductor XLPE insulated and PVC sheathed armoured / unarmoured cable conforming to IS 1554 (Part-I) 1988.. Make ; RR Kable, Havells, Polycab, KEI Or equivalent as approved 4 Core, 6 sq.mm. XLPE ARMOURED Aluminium Cable. Form transformer to MDB
CEILING & EXHAUST FAN Installation, testing and commissioning of ceiling fan including wiring the down rods of standard length (upto 30 cm) with 1.5 sq.mm FR PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required.
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Labour for test boring with 40mm (internal) dia G.I. Pipes including keeping surplus of earth and every 2.00m after first 3.00m depth and delivering the same in nearest P.W.D. camp in the small tin container (container, scaffolding, tools etc. will have to be arranged by the contractor at his own cost).
Machine boring tube well pipes with Truck Mounted rotary/ Tubewell boring machine through different soil/ rock media including hire charges of drill pipes, scaffolding, tools and plants as necessary and taking out the same and lowering pipes, fittings complete as directed by the Department. Bore hole of 200mm diameter
Supplying, fitting and fixing pipes plain/bevel ended for casing, conforming to relevant IS codes of practice including supplying and fitting of tube well accessories, lowering of assembly pipes concentrically in the borehole followed by supplying and packing of pea gravel free from dirt, dust and other foreign materials in the annular space between the borehole and assembly pipes complete as directed by the Department. PVC PIPE of SUPREME /PRINCE / FUSION /SFMC Brand or equivalent 160mm diameter
Supplying, fitting and fixing pipes plain/bevel ended for casing, conforming to relevant IS codes of practice including supplying and fitting of tube well accessories, lowering of assembly pipes concentrically in the borehole followed by supplying and packing of pea gravel free from dirt, dust and other foreign materials in the annular space between the borehole and assembly pipes complete as directed by the Department. PVC PIPE of SUPREME /PRINCE / FUSION /SFMC Brand or equivalent 200mm diameter
Supplying, fitting and fixing suction pipes plain/bevel ended, conforming to relevant IS codes of practice including supplying and fitting of accessories, lowering of assembly pipes concentrically in the casing pipes complete as directed. PVC PIPE of SUPREME / PRINCE / FUSION /SFMC Brand or equivalent. 50mm diameter
Supplying fitting and fixing ribbed screen PVC filter 3.00 metre long conforming to relevant IS codes of practice including fitting with assembly pipes of tube well and supplying and packing of pea gravel free from dirt, dust and other foreign materials in the annular space between the borehole and assembly pipes complete as directed by the Department. 50mm diameter
Supplying fitting and fixing check valve (non return valve) including thread to pipes complete as directed by the Department. 50mm diameter
Development of the tube well with compressor or by over pumping unit for 48 hours till sand free discharge is obtained
Flushing, clearing, washing and watering of the tube well
Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External work 40 mm dia nominal bore
Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External work 50 mm dia nominal bore
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 50 mm dia nominal bore
Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) : 50 mm dia nominal bore
Three phase Submersible motor pump set (Texmo / Crompton Greaves/ Aquatic/ CRI/ V-Guar suitable for 100 mm bore well and above. 1 HP STAGE 5 to 18 with MCB controlled Submersible motor pump set control panel.
1 HP single Phase jet pump set (Horizontal(Crompton Greaves/ Aquatic/ CRI/ V-Guard make) 2900 rpm with DOL Starter ( Crompton Greaves/ Control & Switch Gear/ BCH/ L& T / Siemens make) .
Supplying and fixing of Pure Epoxy Chemical anchoring grout rebaring chemical of Fosroc LOKFIX E75/ Hilti RE500 V3 or equivalent make - for anchoring various MS bolts or Rebars upto a maximum embedment depth of 300mm in Masonry/ RCC strata complete as per manufacturer's specifications and as directed by Engineer. For 20mm Dia Bolt for canopy
Wiring in surface/ recessed PVC conduit FR (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) cable Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) including earth continuity in surface/ recessed 20 mm. dia. 2mm thick/ heavy ISI marked IS: 9537 PART - III rigid PVC conduit wiring system. With 2 x 2.5 sq. mm. + earth continuity with 1x1.5 sq. mm. in 20 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.
Wiring in surface/ recessed PVC conduit FR (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) cable Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) including earth continuity in surface/ recessed 20 mm. dia. 2mm thick/ heavy ISI marked IS: 9537 PART - III rigid PVC conduit wiring system. With 2 x 4 sq. mm. + earth continuity with 1x2.5 sq. mm. cable in 20 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.
Wiring in surface/ recessed PVC conduit FR (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) cable Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) including earth continuity in surface/ recessed 20 mm. dia. 2mm thick/ heavy ISI marked IS: 9537 PART - III rigid PVC conduit wiring system. With 2 x 6 sq. mm. + earth continuity with 1x 4 sq. mm. cable in 25 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.
Wiring in surface/ recessed PVC conduit FR (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) cable Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) including earth continuity in surface/ recessed 20 mm. dia. 2mm thick/ heavy ISI marked IS: 9537 PART - III rigid PVC conduit wiring system. With 2 x 10 sq. mm. + earth continuity with 1x 6 sq. mm. cable in 25 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.
Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed PVC 20 mm. dia. 2mm thick/ heavy ISI marked IS: 9537 PART - III rigid PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) wiring system. With 4 x 10 sq. mm. + earth continuity with 2x6 sq. mm. cable in 40 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.
Wiring for 5 pin 6 amp plug with 1.5 sq mm P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) including 5 pin 6 amp socket outlet (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.)make) and 6 amp flush type switch (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.)make) earthing the 3rd pin of the socket as required on the switch board in surface/ recessed P.V.C. conduit wiring system. When fitted on same board of light and fan.
Wiring to 5 a pin 6 Amps plug point with 1.5 sq. mm P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed 2 mm thick/ heavy rigid ISI marked IS: 9537 PART - III rigid PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) wiring system including earth continuity with 1.5 sq. mm. cable to third pin of the plug socket etc. as required complete. Short point up to 3.00 metre. length.
Wiring to 5 a pin 6 Amps plug point with 1.5 sq. mm P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed 2 mm thick/ heavy rigid ISI marked IS: 9537 PART - III rigid PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) wiring system including earth continuity with 1.5 sq. mm. cable to third pin of the plug socket etc. as required complete. Medium point up to 6.00 metre. Length.
Wiring for 5/6 pin 16 Amps power plug point with 4 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed conduit wiring system including earth continuity with 2.5 sq. mm cable to the 3rd pin of the socket as required complete with 20 mm. dia. 2mm thick/ heavy ISI marked IS: 9537 PART - III rigid PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) Short point up to 3.00 metre. length.
Wiring for 5/6 pin 16 Amps power plug point with 4 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed conduit wiring system including earth continuity with 2.5 sq. mm cable to the 3rd pin of the socket as required complete with 20 mm. dia. 2mm thick/ heavy ISI marked IS: 9537 PART - III rigid PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) Medium point up to 6.00 metre. Length.
Wiring for light/fan/call bell point with 3x1.5 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed conduit wiring system with 20mm dia 2mm thick / heavy rigid PVC IS: 9537 Part - III conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) ceiling rose etc. complete Short point up to 3.00 metre. length.
Wiring for light/fan/call bell point with 3x1.5 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed conduit wiring system with 20mm dia 2mm thick / heavy rigid PVC IS: 9537 Part - III conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) ceiling rose etc. complete Medium point up to 6.00 metre. Length.
Wiring for light/fan/call bell point with 3x1.5 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed conduit wiring system with 20mm dia 2mm thick / heavy rigid PVC IS: 9537 Part - III conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) ceiling rose etc. complete Long point up to 10.00 metre. Length.
Supplying including fitting fixing of following A.C. Exhaust fan in the existing hole on the wall of following sweeps with making necessary connection as approved by the Deptt.)as required complete and as directed by the Department. Heavy Duty 450 mm sweep 900 RPM Single phase (ORIENT make) [EFH ]
Supplying, fitting fixing of LED Batten Tubes high quality aluminium extruded with decorative end caps connection with 1.5 Sq.mm 1 core PVC insulated round copper conductor as required and as directed by the department. B118601000 [FL]
MODULAR SWITCH Supplying including and fixing of following Metal boxes for MODEL RANGE LEGRAND (MYRIUS), ANCHOR (VIOLA), MK (WRAPAROUND/ PLUS), ABB (CHEIRON), KOLORS (KREST), SCHNEIDER (VIVACE), CRABTREE in surface/ recessed system complete as per direction of department. 3 module type Metal
MODULAR SWITCH Supplying including and fixing of following Metal boxes for MODEL RANGE LEGRAND (MYRIUS), ANCHOR (VIOLA), MK (WRAPAROUND/ PLUS), ABB (CHEIRON), KOLORS (KREST), SCHNEIDER (VIVACE), CRABTREE in surface/ recessed system complete as per direction of department. 12-16 module type Metal
Supplying including fitting fixing of following front plate of suitable colour MODEL RANGE LEGRAND (MYRIUS), ANCHOR (VIOLA), MK (WRAPAROUND/ PLUS), ABB (CHEIRON), KOLORS (KREST), SCHNEIDER (VIVACE), CRABTREE as per direction of department. 3 module
Supplying including fitting fixing of following front plate of suitable colour MODEL RANGE LEGRAND (MYRIUS), ANCHOR (VIOLA), MK (WRAPAROUND/ PLUS), ABB (CHEIRON), KOLORS (KREST), SCHNEIDER (VIVACE), CRABTREE as per direction of department. 16 module
Supplying with fitting fixing of blank plate single in modular switch system MODEL RANGE LEGRAND (MYRIUS), ANCHOR (VIOLA), MK (WRAPAROUND/ PLUS), ABB (CHEIRON), KOLORS (KREST), SCHNEIDER (VIVACE), CRABTREE complete as per direction of department.
Supplying including installation of socket outlet 6/16 Amps 3/5 pin combine shuttered complete , MODEL RANGE LEGRAND (MYLINC), ANCHOR (ROMA), MK (IVORY), ABB (CLASSIC), KOLORS (KRAZE), SCHNEIDER (OPAL), PHILIPS, Havells including making necessary connection as per direction of department.
Supplying with fitting fixing of 16 amp one way modular clip in switch, MODEL RANGE LEGRAND (MYLINC), ANCHOR (ROMA), MK (IVORY), ABB (CLASSIC), KOLORS (KRAZE), SCHNEIDER (OPAL), PHILIPS, Havells including making necessary connection as per direction of department.
Supplying with fitting fixing of 6 amp one way modular clip in switch, MODEL RANGE LEGRAND (MYLINC), ANCHOR (ROMA), MK (IVORY), ABB (CLASSIC), KOLORS (KRAZE), SCHNEIDER (OPAL), PHILIPS, Havells including making necessary connection as per direction of department.
SUPPLY AND FIXING OF RIGID PVC CONDUIT (AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) IN SURFACE AND RECESS WIRING SYSTEM Supply and fixing 19 mm dia 2.00mm average wall thickness heavy rigid PVC IS: 9537 Part - III conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) in recessed system including cutting the wall and making good the same as required:
Wiring with P.V.C. insulated unsheathed 1.1 K.V. grade single core copper conductor FR cable in existing surface/ recessed conduit wiring system Wiring for Co - axial Jelly Flooded (Unarmoured) (FINOLEX /RR KABEL /NICCO / ANCHOR make) cable in existing surface conduit wiring system including connection etc as required. Co - axial Jelly Flooded (Unarmoured) RG 6 (Copper)
FITTINGS AND ACCESSORIES (ALL PRODUCTS SHOULD BE ENERGY EFFICIENT AND ENVIRONMENT FRIENDLY) Supplying and fixing of bulk head fitting suitable for CFL lamp complete with all accessories including 20 watts CFL lamp and connection as approved by the Deptt.)as required. [BH ]
SWITCH GEAR & PROTECTION INDUSTRIAL SOCKETS, DB WITHOUT MCB & MCCB , MCB, RCCB, RCBO, SFU, CHANGE OVER ETC. (C&S, Havells, INDOASIAN, HPL OR EQUIVALENT as approved by the Deptt.)MAKE) Supplying fitting and fixing industrial Plug & Socket in surface mounting SPN sheet steel powder painted MCB DB incorporated with MCB DIN rail, neutral link Earth bar of the following rating of DP MCB complete with making necessary connection etc. as specified and directed by the Deptt. 20A Capacity. (C&S, Havells, INDOASIAN, HPL or equivalent as approved by the Deptt.)make)
Supplying with fitting and fixing sheet steel, phosphatised, powder painted Single door surface mounting MCB enclosure incorporated with bas-bar, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt. Schneider neo break, C&S, Havells, INDOASIAN, HPL or equivalent as approved by the Deptt.)make) 2 way single door
Supplying with fitting and fixing sheet steel, phosphatised, powder painted Single door surface mounting MCB enclosure incorporated with bas-bar, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt. Schneider neo break, C&S, Havells, INDOASIAN, HPL or equivalent as approved by the Deptt.)make) 4 way single door
MCB DB (ABB, SCHNEIDER MG, LEGRAND, HAGER MAKE) & (SCHNEIDER NEO BREAK, C&S, Havells, INDOASIAN, HPL OR EQUIVALENT MAKE AS PPROVED BY THE DEPTT. MCB IN-comer SPN DB Supplying with fitting and fixing sheet steel, phosphatised, powder painted dust & vermin proof Double door IP-43 surface mounting SPN MCB DB incorporated with bas-bar, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt. ABB, Schneider MG, legrand, Hager make) 8 way SPN Double Door
MCB DB (ABB, SCHNEIDER MG, LEGRAND, HAGER MAKE) & (SCHNEIDER NEO BREAK, C&S, Havells, INDOASIAN, HPL OR EQUIVALENT MAKE AS PPROVED BY THE DEPTT. MCB IN-comer SPN DB Supplying with fitting and fixing sheet steel, phosphatised, powder painted dust & vermin proof Double door IP-43 surface mounting SPN MCB DB incorporated with bas-bar, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt. ABB, Schneider MG, legrand, Hager make) 12 way SPN Double Door
MCB IN-comer TPN (Horizontal DB) Supplying with fitting and fixing sheet steel, phosphatised, powder painted dust & vermin proof Double door IP-43 double door surface mounting TPN MCB DB incorporated with bas-bar, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt. ABB, Schneider MG, legrand, Hager make) 4 way TPN (4+12) double door
MCB IN-comer (TPN VERTICAL DB) Supplying with fitting and fixing MCCB income and MCB outgoing sheet steel, phosphatised, powder painted double door IP-43 surface mounting vertical TPN MCB DB incorporated with bas-bar up to 250A, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt. ABB, Schneider MG, legrand, Hager make) 4 way TPN (4+12) double door
MCB, MCCB, RCCB, RCBO (ABB, SCHNEIDER MG, LEGRAND, AND HAGER MAKE) & (SCHNEIDER NEO BREAK, C&S, Havells, INDO ASIAN, HPL OR EQUIVALENT MAKE AS PPROVED BY THE DEPTT.) MCB (Conform to IS / IEC 60898-1:200/ MCCB (Conform to IS/IEC 60947- RCCB (Conform to IS/IEC 12640 / 61008) Supplying with fitting and fixing single Pole 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. C Series (Schneider MG, legrand, Hager make) 6 to 32A
Supplying with fitting and fixing DP 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. C Series (ABB, Schneider MG, legrand, Hager make) 6 to 32A
Supplying with fitting and fixing 30/100/300mA sensitivity 240/415V 50Hz DP RCCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. 100/300mA sensitivity DP RCCB (ABB, Schneider MG, legrand, Hager make) 25A
Supplying with fitting and fixing 30/100/300mA sensitivity 240/415V 50Hz DP RCCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. 100/300mA sensitivity DP RCCB (ABB, Schneider MG, legrand, Hager make) 40A
Supplying with fitting and fixing TP 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. C Series (ABB, Schneider MG, legrand, Hager make) 6 to 32A
Supply, fitting & fixing of Lighting Finial Arrestor made of 25 mm dia 300 mm long solid G.I. tube having 85 mm dia. single prong at top and 3 mm base plate at bottom complete with fitting & fixing with G.I. nuts & bolts on roof, RCC slab, top of column etc. as specified and directed by the deptt.
Supply, fitting & fixing 20 mmx5 mm G.I. strips drawn on vertically or horizontally on building wall/parapet wall in surface system complete with supply of G.I. Nuts & Bolts, Screws etc including riveting, soldering and making connection as approved by the Deptt.)with earth electrode G.I. strips and Lightning Arrestor etc. as specified and directed by the deptt.
HYDRANT SYSTEM Providing,Fixing, testing &Commissioning of Single Headed Gun Metal ISI Marked oblique pattern Hydrant Landing Valve with 80 mm dia, flanged inlet & 63 mm dia instantaneous type female outlet complete with cap and chain, twist release lug and all accessories as per IS:5290-19833 (Type-'A') and specifications complete as reequired . (MAKE:ESSEL/WINCO/NEWAGE)
Providing RRL Hose with ISI Marked (IS:636) 63 mm dia X15 M long complete with instantaneous type Gun Metal 3 mm dia ISI Marked male & female couplings (IS:903) bound & riveted to hose pipes with copper rivets and copper wire complete as reqd. ( MAKE: NIRMAL RUBBER/NEWAGE)
Providing & fixing of Gun Metal fire Brigade connection (withdrawl connecting head) consisting of 63mm instantaneous type male coupling with built in check valves and 150mm dia flanged outlet complete with bolts, nuts and rubber insertions as per IS:904-1983 complete as reqd. MAKE: ESSEL/WINCO/NEWAGE a) 2 way
Providing & Fixing of Weather Proof M.S. Cabinet (to enclose above Inlet Collection Head Connection) fabricated from 16 S.W.G. M.S. sheet centre opening with 3 mm thick full front glass door and locking arrangement duly painted with one coat of primer and two or more coasts of synthetic enamel paint of appreoved make and shade and suitably mounted. Exact size and shape shall be subject to site conditions and prior approval.
Providing & fixing of Gun Metal fire Brigade suction hose coupling (draw out connection) with nut for female coupling as per IS:902- 1974 complete with 150 mm dia GI suction pipe and foot valve (to
Providing ,Fixing ,Testing & Commissioning of air Release Valve a) 50 mm dia
Providing,Fixing,Testing & Commissioning of Mild Steel Black Pipe(IS:1239part-I) Heavy class including cutting, screwing, welding etc. and providing all fittings viz forged steel screwed fitting upto 50mm dia and bolt welded above 50mm dia flanges, bends, tees, reducers, elbow, clamps, hangers etc including cutting holes and chases in brick or RCC walls/ slabs and making good the same to the approval of Engineer-in-charge/ consultant complete including painting with one coat of primer and two or more coats of synthetic enamel paint of approved make and shade including steel work complete as required. (Make:TATA/JINDAL/NEZONE) b) 150 mm dia
Providing,Fixing,Testing & Commissioning of Mild Steel Black Pipe(IS:1239part-I) Heavy class including cutting, screwing, welding etc. and providing all fittings viz forged steel screwed fitting upto 50mm dia and bolt welded above 50mm dia flanges, bends, tees, reducers, elbow, clamps, hangers etc including cutting holes and chases in brick or RCC walls/ slabs and making good the same to the approval of Engineer-in-charge/ consultant complete including painting with one coat of primer and two or more coats of synthetic enamel paint of approved make and shade including steel work complete as required. (Make:TATA/JINDAL/NEZONE) c) 100 mm dia
Providing,Fixing,Testing & Commissioning of Mild Steel Black Pipe(IS:1239part-I) Heavy class including cutting, screwing, welding etc. and providing all fittings viz forged steel screwed fitting upto 50mm dia and bolt welded above 50mm dia flanges, bends, tees, reducers, elbow, clamps, hangers etc including cutting holes and chases in brick or RCC walls/ slabs and making good the same to the approval of Engineer-in-charge/ consultant complete including painting with one coat of primer and two or more coats of synthetic enamel paint of approved make and shade including steel work complete as required. (Make:TATA/JINDAL/NEZONE) d) 80 mm dia
Providing,Fixing,Testing & Commissioning of Mild Steel Black Pipe(IS:1239part-I) Heavy class including cutting, screwing, welding etc. and providing all fittings viz forged steel screwed fitting upto 50mm dia and bolt welded above 50mm dia flanges, bends, tees, reducers, elbow, clamps, hangers etc including cutting holes and chases in brick or RCC walls/ slabs and making good the same to the approval of Engineer-in-charge/ consultant complete including painting with one coat of primer and two or more coats of synthetic enamel paint of approved make and shade including steel work complete as required. (Make:TATA/JINDAL/NEZONE) g) 40 mm dia
Providing,Fixing,Testing & Commissioning of Mild Steel Black Pipe(IS:1239part-I) Heavy class including cutting, screwing, welding etc. and providing all fittings viz forged steel screwed fitting upto 50mm dia and bolt welded above 50mm dia flanges, bends, tees, reducers, elbow, clamps, hangers etc including cutting holes and chases in brick or RCC walls/ slabs and making good the same to the approval of Engineer-in-charge/ consultant complete including painting with one coat of primer and two or more coats of synthetic enamel paint of approved make and shade including steel work complete as required. (Make:TATA/JINDAL/NEZONE) i) 25 mm dia
Providing,Fixing,Testing & Commissioning of Mild Steel Black Pipe(IS:1239part-I) Heavy class including cutting, screwing, welding etc.complete with all fittings (butt welded) viz flanges, bends, tees, elbows, reducers etc including excavation (upto 1.5 m Deep), back filling and removal of surplus soil & providing anti corrosive treatment(coating and wrapping) as per IS:10221 with 4 mm thicka) 200 mm dia
Providing,Fixing,Testing & Commissioning of Mild Steel Black Pipe(IS:1239part-I) Heavy class including cutting, screwing, welding etc.complete with all fittings (butt welded) viz flanges, bends, tees, elbows, reducers etc including excavation (upto 1.5 m Deep), back filling and removal of surplus soil & providing anti corrosive treatment(coating and wrapping) as per IS:10221 with 4 mm thickb) 150 mm dia
Providing,Fixing,Testing & Commissioning of Mild Steel Black Pipe(IS:1239part-I) Heavy class including cutting, screwing, welding etc.complete with all fittings (butt welded) viz flanges, bends, tees, elbows, reducers etc including excavation (upto 1.5 m Deep), back filling and removal of surplus soil & providing anti corrosive treatment(coating and wrapping) as per IS:10221 with 4 mm thickc) 100 mm dia
Supplying & Fixing Cast iron body Non Return valves complete with matching flanges, rubber insertion, nuts, bolts and washer etc. (IS:5312) of following sizes complete as reqd.a) 150 mm dia
Supplying & Fixing Cast iron body Non Return valves complete with matching flanges, rubber insertion, nuts, bolts and washer etc. (IS:5312) of following sizes complete as reqd.b) 100 mm dia
Supplying & Fixing,cast iron body Butterfly Valves with matching flanges, rubber insertion, nuts, bolts and washer etc (IS:13095) of following size complete as reqd.c) 100 mm dia
Providing ,Fixing,Testing & Commissioning of G.M. Stop Valve ISI Marked screwed type tested to 30Kg/cm2 pressure as per IS:778- 1984 of following sizes complete as reqd.a) 50 mm dia
Providing, erection testing, Commissioning of Cast Iron Foot Valve/Stainer confirming to IS:4038/1538 complete with flanges, nuts, bolts and washer etc as requiredb) 150 mm dia
Providing,erection testing & commissioning of pressure gauge 100 mm dia (0-10Kg/cm2)
Providing ,erection,Testing & Commissioning of Pressure Switch (MAKE:INDFOSS)
Supplying, Installation,Testing & Commissioning of 15 mm dia quartzoid Bulb Type G.M. Sprinkler Head sutable to operate at 68* C complete as reqd.(UL/FM/LPC listed/Approved)
Supplying, Installation, Testing & Commissioning of First Aid Hose reel drawn with 30 Mtrs. Long rubber hose and G.M shut off nozzle, 25mm dia Gate valve, Union pipe complete set confirming to IS: 884.
Supply, Installation, Fixing of DRY CHEMICAL POWDER Fire Extinguisher confirming to IS: 2171 with ISI mark and CO2 cartridge will be confirming to IS: 4947 with ISI mark, Powder will be confirming to IS: 4308 with ISI Mark (5 KG) BRAND : FIRESTOP / FIREND / FIRE SHIELD
Supply, Installation, Fixing of DRY CHEMICAL POWDER Fire Extinguisher confirming to IS: 2171 with ISI mark and CO2 cartridge will be confirming to IS: 4947 with ISI mark, Powder will be confirming to IS: 4308 with ISI Mark (10 kg) BRAND : FIRESTOP / FIREND / FIRE SHIELD
Supply, Installation, Fixing of MECHANICAL FOAM (AFFF) Fire Extinguisher confirming to IS: 10204 with ISI Mark and CO2 Cartridge will be confirming to IS: 4947 with ISI mark, (AFFF) will be confirming to IS: 4989 with ISI Mark.(9 LTRS) BRAND : FIRESTOP / FIREND / FIRE SHIELD
Supply, Installation, Fixing of CARBON DIOXIDE Fire Extinguisher confirming to IS: 2878 with ISI Mark.(4.5 LITERS) BRAND: FIRESTOP / FIREND / FIRESHIELD
Supplying, installation, testing and commissioning of Electric driven Main Fire Pump suitable for automatic operation and consisting of following, complete in all respects, as required : (a) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520. (b) Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325.2280 lpm at 70 m Head
Supplying, installation, testing and commissioning of diesel engine driven main fire pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Diesel Driven Pump) Horizontal type, multistage, centrifugal pump of cast of iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520. Suitable HP, 1500 RPM water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12 /24 volts electric starting equipment, diesel tank, exhaust pipe extended upto 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification,2280 lpm at 70 m Head
Supplying, installation, testing and commissioning of electric driven pressurisation pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Jockey Pump) Horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS : 1520. Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase 50 Hz AC supply with IP 55 class of protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS : 325. M.S.fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. Suitable cement concrete foundation duly plastered and with anti vibration pads180 lpm at 70 m Head
Providing and fixing Fire pump with CI body, bronze impeller, shaft coupled by means of flexible coupling with electric motor/engine Antivibration pads,, coupling guard , baseplate etc. Electric Motor Driven Sprinkler pump. Head = 20 Meters, H.P.=17.5
Supplying, installation, testing & commissioning of manual call boxes of MS construction in surface/recess with stainless steel chain & hammer assembly complete with glass and push button
Supplying, installation, testing & commissioning response indicator on surface/recess MS box having two LEDs metallic cover complete with all connections etc. as required
Supplying, installation, testing & commissioning fire alarm sounder with facility to make announcement, mounted in M.S. box (16 SWG) with hinged cover plate & suitable for operation with amplifier i/c line matching transformer etc. complete as required.
AIR VESSEL Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approved shade as required.
Supply, application, testing of PYPKOTE Anti-corrosive (4mm thick)
HYDRANT SYSTEM Providing,Fixing, testing &Commissioning of Single Headed Gun Metal ISI Marked oblique pattern Hydrant Landing Valve with 80 mm dia, flanged inlet & 63 mm dia instantaneous type female outlet complete with cap and chain, twist release lug and all accessories as per IS:5290-19833 (Type-'A') and specifications complete as reequired . (MAKE:ESSEL/WINCO/NEWAGE)
Providing RRL Hose with ISI Marked (IS:636) 63 mm dia X15 M long complete with instantaneous type Gun Metal 3 mm dia ISI Marked male & female couplings (IS:903) bound & riveted to hose pipes with copper rivets and copper wire complete as reqd. ( MAKE: NIRMAL RUBBER/NEWAGE)
Providing & fixing of Gun Metal fire Brigade connection (withdrawl connecting head) consisting of 63mm instantaneous type male coupling with built in check valves and 150mm dia flanged outlet complete with bolts, nuts and rubber insertions as per IS:904-1983 complete as reqd. MAKE: ESSEL/WINCO/NEWAGEa) 2 way
Providing & Fixing of Weather Proof M.S. Cabinet (to enclose above Inlet Collection Head Connection) fabricated from 16 S.W.G. M.S. sheet centre opening with 3 mm thick full front glass door and locking arrangement duly painted with one coat of primer and two or more coasts of synthetic enamel paint of appreoved make and shade and suitably mounted. Exact size and shape shall be subject to site conditions and prior approval.
Providing & fixing of Gun Metal fire Brigade suction hose coupling (draw out connection) with nut for female coupling as per IS:902- 1974 complete with 150 mm dia GI suction pipe and foot valve (to
Providing ,Fixing ,Testing & Commissioning of air Release Valvea) 50 mm dia
Providing,Fixing,Testing & Commissioning of Mild Steel Black Pipe(IS:1239part-I) Heavy class including cutting, screwing, welding etc. and providing all fittings viz forged steel screwed fitting upto 50mm dia and bolt welded above 50mm dia flanges, bends, tees, reducers, elbow, clamps, hangers etc including cutting holes and chases in brick or RCC walls/ slabs and making good the same to the approval of Engineer-in-charge/ consultant complete including painting with one coat of primer and two or more coats of synthetic enamel paint of approved make and shade including steel work complete as required. (Make:TATA/JINDAL/NEZONE) b) 150 mm dia
Providing,Fixing,Testing & Commissioning of Mild Steel Black Pipe(IS:1239part-I) Heavy class including cutting, screwing, welding etc. and providing all fittings viz forged steel screwed fitting upto 50mm dia and bolt welded above 50mm dia flanges, bends, tees, reducers, elbow, clamps, hangers etc including cutting holes and chases in brick or RCC walls/ slabs and making good the same to the approval of Engineer-in-charge/ consultant complete including painting with one coat of primer and two or more coats of synthetic enamel paint of approved make and shade including steel work complete as required. (Make:TATA/JINDAL/NEZONE)c) 100 mm dia
Providing,Fixing,Testing & Commissioning of Mild Steel Black Pipe(IS:1239part-I) Heavy class including cutting, screwing, welding etc. and providing all fittings viz forged steel screwed fitting upto 50mm dia and bolt welded above 50mm dia flanges, bends, tees, reducers, elbow, clamps, hangers etc including cutting holes and chases in brick or RCC walls/ slabs and making good the same to the approval of Engineer-in-charge/ consultant complete including painting with one coat of primer and two or more coats of synthetic enamel paint of approved make and shade including steel work complete as required. (Make:TATA/JINDAL/NEZONE) d) 80 mm dia
Providing,Fixing,Testing & Commissioning of Mild Steel Black Pipe(IS:1239part-I) Heavy class including cutting, screwing, welding etc. and providing all fittings viz forged steel screwed fitting upto 50mm dia and bolt welded above 50mm dia flanges, bends, tees, reducers, elbow, clamps, hangers etc including cutting holes and chases in brick or RCC walls/ slabs and making good the same to the approval of Engineer-in-charge/ consultant complete including painting with one coat of primer and two or more coats of synthetic enamel paint of approved make and shade including steel work complete as required. (Make:TATA/JINDAL/NEZONE)g) 40 mm dia
Providing,Fixing,Testing & Commissioning of Mild Steel Black Pipe(IS:1239part-I) Heavy class including cutting, screwing, welding etc. and providing all fittings viz forged steel screwed fitting upto 50mm dia and bolt welded above 50mm dia flanges, bends, tees, reducers, elbow, clamps, hangers etc including cutting holes and chases in brick or RCC walls/ slabs and making good the same to the approval of Engineer-in-charge/ consultant complete including painting with one coat of primer and two or more coats of synthetic enamel paint of approved make and shade including steel work complete as required. (Make:TATA/JINDAL/NEZONE) i) 25 mm dia
Providing,Fixing,Testing & Commissioning of Mild Steel Black Pipe(IS:1239part-I) Heavy class including cutting, screwing, welding etc.complete with all fittings (butt welded) viz flanges, bends, tees, elbows, reducers etc including excavation (upto 1.5 m Deep), back filling and removal of surplus soil & providing anti corrosive treatment(coating and wrapping) as per IS:10221 with 4 mm thick a) 200 mm dia
Providing,Fixing,Testing & Commissioning of Mild Steel Black Pipe(IS:1239part-I) Heavy class including cutting, screwing, welding etc.complete with all fittings (butt welded) viz flanges, bends, tees, elbows, reducers etc including excavation (upto 1.5 m Deep), back filling and removal of surplus soil & providing anti corrosive treatment(coating and wrapping) as per IS:10221 with 4 mm thick b) 150 mm dia
Providing,Fixing,Testing & Commissioning of Mild Steel Black Pipe(IS:1239part-I) Heavy class including cutting, screwing, welding etc.complete with all fittings (butt welded) viz flanges, bends, tees, elbows, reducers etc including excavation (upto 1.5 m Deep), back filling and removal of surplus soil & providing anti corrosive treatment(coating and wrapping) as per IS:10221 with 4 mm thick c) 100 mm dia
Supplying & Fixing Cast iron body Non Return valves complete with matching flanges, rubber insertion, nuts, bolts and washer etc. (IS:5312) of following sizes complete as reqd. a) 150 mm dia
Supplying & Fixing Cast iron body Non Return valves complete with matching flanges, rubber insertion, nuts, bolts and washer etc. (IS:5312) of following sizes complete as reqd. b) 100 mm dia
Supplying & Fixing,cast iron body Butterfly Valves with matching flanges, rubber insertion, nuts, bolts and washer etc (IS:13095) of following size complete as reqd. c) 100 mm dia
Providing ,Fixing,Testing & Commissioning of G.M. Stop Valve ISI Marked screwed type tested to 30Kg/cm2 pressure as per IS:778- 1984 of following sizes complete as reqd. a) 50 mm dia
Providing, erection testing, Commissioning of Cast Iron Foot Valve/Stainer confirming to IS:4038/1538 complete with flanges, nuts, bolts and washer etc as required b) 150 mm dia
Providing,erection testing & commissioning of pressure gauge 100 mm dia (0-10Kg/cm2)
Providing ,erection,Testing & Commissioning of Pressure Switch (MAKE:INDFOSS)
Supplying, Installation,Testing & Commissioning of 15 mm dia quartzoid Bulb Type G.M. Sprinkler Head sutable to operate at 68* C complete as reqd.(UL/FM/LPC listed/Approved)
Supplying, Installation, Testing & Commissioning of First Aid Hose reel drawn with 30 Mtrs. Long rubber hose and G.M shut off nozzle, 25mm dia Gate valve, Union pipe complete set confirming to IS: 884.
FIRE EXTINGUISHER Supply, Installation, Fixing of DRY CHEMICAL POWDER Fire Extinguisher confirming to IS: 2171 with ISI mark and CO2 cartridge will be confirming to IS: 4947 with ISI mark, Powder will be confirming to IS: 4308 with ISI Mark (5 KG) BRAND : FIRESTOP / FIREND / FIRE SHIELD
Supply, Installation, Fixing of DRY CHEMICAL POWDER Fire Extinguisher confirming to IS: 2171 with ISI mark and CO2 cartridge will be confirming to IS: 4947 with ISI mark, Powder will be confirming to IS: 4308 with ISI Mark (10 kg) BRAND : FIRESTOP / FIREND / FIRE SHIELD
Supply, Installation, Fixing of MECHANICAL FOAM (AFFF) Fire Extinguisher confirming to IS: 10204 with ISI Mark and CO2 Cartridge will be confirming to IS: 4947 with ISI mark, (AFFF) will be confirming to IS: 4989 with ISI Mark.(9 LTRS) BRAND : FIRESTOP / FIREND / FIRE SHIELD
Supply, Installation, Fixing of CARBON DIOXIDE Fire Extinguisher confirming to IS: 2878 with ISI Mark.(4.5 LITERS) BRAND: FIRESTOP / FIREND / FIRESHIELD
7.5M OVERHEAD SIGN-BOARD Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. Ordinary soil Upto 3 m depth
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 With crushed Stone R.C.C Grade M20
Supplying, fitting and placing MS Bar (Fe-500 ) reinforcement bar (From Primary Producer: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel/RINL) in foundation complete as per drawings and technical specifications Clauses 1000 and 1202
Providing and erecting overhead signs of anti-corrosive steel tubular framed structure (all the steel work must be TATA/ SAIL/ any other approved brand) for retro reflective signage boards made of high intensity grade encapsulated lens type retro Reflective sheeting conforming to ASTMD4956 type B III specifications and having approved pattern over its entire surface bonded on to 2.00 mm thick aluminium sheet with back supporting angle iron frame of 35x35x4mm angle iron duly riveted with solid MS & aluminum rivets. The entire face of the sign shall be covered & bounded with yellow/ white/ red/ blue high intensity encapsulated lens reflective sheeting with distinctive hoed pattern on front side (no plain surface) with heat lamp vacuum applicator machine only. The yellow/ white/ red/ blue portion of the board shall be screen printed on the high intensity shed base including fixing the board on portal/ support/ wall/ dowel rod etc., with connecting clamps/ cleats/ bolts/ rivets/ wells including all materials, labour, tools, lead & lifts etc. complete and all other incidental charges necessary for successful completion of work as per specifications and as directed. Steel section
Providing retro reflective sign board of high intensity grade reflective sheeting conforming to ASTMD4956 B-III specifications having approved pattern over its entire surface bonded on to 2 mm thick aluminium sheeting, the entire face of the sign shall be covered & bounded with yellow/ white/ red/ blue high intensity grade with distinctive nod pattern on front side with heat lamp vacuum applicator machine only.
Providing and applying two coats of ready mix paint including primer coat of approved brand on steel surface after through cleaning of surface to give an even shade as per drawing and Technical Specification Clause 1701
REASSURANCE SIGN Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 made of encapsulated lens type reflective sheeting vide Clause 1701.2.3 fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawings and Technical Specification Clause 801800mm x 600mm rectangular
ROAD MARKING Painting lines, dashes, arrows, etc. on roads in two coats on new work with ready mixed road marking paint conforming to IS:164 on bituminous/concrete surface, including cleaning the surface of all dirt, dust and other foreign matter, demarcation at site and traffic control as per drawing and Technical Specification Clause 1702
Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 With crushed Stone P.C.C grade M 10 Nominal mix 1:3:6
Load security to be deposited to concerned Power Supply Agency and Supervision Charges to be paid to APDCL complete for drawing of requisite overhead line with necessary insulators angles frames stay wires etc. as necessary including obtaining of permissions from Power Supply Authority and all necessary liasioning with the concerned departments etc. as directed.
Supplying, installation testing and commissioning of the following rating copper wound indoor / out door type transformer complete including the payment to be made to power supply authority for supervision charge, labour charge, cost of L.T/H.T metering etc. (excluding the cost of load security) and making necessary arrangement for charging approval of the sub-station from the competent authority as directed and specified by the department. Transformer should be as per CEA guidelines as ammended up to date upto 200 KVA star rating up to 5 star, above 200KVA as per CEA guidelines for losses along with LV enclosure. 100 KVA,50Hz.11/0.433 KV. Oil filled transformer with Off Circuit tap change.
Supplying & laying of 8 SWG Copper. earth from Earth Electrode (below G.L.) to electrical switch gears or electrical machineries including making necessary connection as approved, specified and directed by the deptt.
Supplying and fitting fixing of galvanised L.T. T cross arm complete with clamps ,blots, nuts etc. as required and as directed by the department.
Supplying and fitting fixing of galvanised channel of 100 mm x 50 mm x 65 x 2200 mm long complete with clamps ,blots, nuts etc. as required and as directed by the department.
Supplying and erection of 11 KV Pin insulator (Poly) with G.I.pin, blots and nuts coach screw etc. as required and as directed by the department.
Supplying and erection of 11 KV Disc insulator (Poly) 45 KN with hard ware fittings etc. as required and as directed by the department.
Supplying and fixing of 11 KV 400 A Gang operated switch with all accessories complete as required and as directed by the department.
Supplying and fixing of 11 KV 150 A D.O. fuse set complete as required and as directed by the department.
Supplying and fixing of 11 KV 5 KA Lighting arrestor (Poly) set complete as required and as directed by the department.
Supplying including installation of 4' dia. C.I. earth pipe complete as required and as directed by the department.
Supplying and fitting fixing of H.T. danger plate complete as required and as directed by the department.
Supplying, erection and commissioning of the following specification as per IS:2713 : 410 SP hot dip Galvanized Steel tubular pole manufacturing out from electrically welded in 3 (three section having a base plate including providing all required building materials as directed and specified by the deptt. (BANSAL/SRP / Valmont / PARUTHI ENGR make) 410 SP 66 Length of pole = 12.00 metre., Length of sections, Bottom = 5.80 M, Middle = 3.10 M, Top = 3.10 M, Out side dia. & Thickness Bottom = 219.10 x 5.60 mm, Middle =193.7 x 4.85 mm, Top =165.10 x 4.50 mm
Supplying with fitting and fixing DP 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. C Series (ABB, Schneider MG, legrand, Hager make) 40A
Supplying with fitting and fixing 4P 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. C Series (ABB, Schneider MG, legrand, Hager make) 40A
Supplying with fitting and fixing panel mounting open execution 25 KA 415V 50Hz 4P MCCB (Ics=Icu, adjustable Ir setting 0.7) without enclosure of the following capacity complete with making necessary connection as approved by the Deptt. as specified and directed by the deptt. 25 KA 415V 50 Hz 4P MCCB (Schneider, legrand, Siemens make) 63A
Supplying with fitting and fixing panel mounting open execution 25 KA 415V 50Hz 4P MCCB (Ics=Icu, adjustable Ir setting 0.7) without enclosure of the following capacity complete with making necessary connection as approved by the Deptt. as specified and directed by the deptt. 25 KA 415V 50 Hz 4P MCCB (Schneider, legrand, Siemens make) 100A
Supplying with fitting and fixing panel mounting open execution 35/36 KA 415V 50Hz 4P MCCB (Ics=Icu, adjustable Ir setting 0.7) without enclosure of the following capacity complete with making necessary connection as approved by the Deptt. as specified and directed by the deptt. 35/36 KA 415V 50 Hz 4P MCCB (Schneider, legrand, Siemens make) 250A
Supplying with fitting and fixing Four Pole 415V Front handle operated On Load Change over switch (IP-20 protection powder painted sheet steel enclosure fitted on angle iron frame of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. ABB, Schneider, legrand, L&T make) 200A
Supply, installation & testing of G.I. earth station with perforated 40 mm dia and 4.50 Metre long heady duty G.I. pipe with necessary 40 mm dia. G.I. Fittings such as Socket, Tee, elbow, nipple and 50 mmx40 mm G.I. reducing socket for funnel including locking arrangement 300 mmx300 mmx6 mm hinged cover C.I. earth plate complete with digging of earth pit, construction of brick chamber and plastering of both inner & outer surface of wall as specified and directed by the deptt .
Extra for using salt (5 K and Charcoal (64 K in pipe Earth Station pit to provide low impedance ground in location of high soil resistivity as and when required and specified by the Deptt.
Supply, installation & testing of Copper Plate earth station with 600 mmx600 mmx3 mm copper earth plate with necessary 40 mm dia. G.I. medium duty watering pipe with G.I. Fittings such as Socket, Tee, elbow, nipple and 50 mmx40 mm G.I. reducing socket for funnel including locking arrangement with 300 mmx300 mmx6 mm C.I. hinged cover plate complete with digging of earth pit, construction of brick chamber and plastering of both inner & outer surface of wall as specified and directed by the deptt .
Extra for using salt (5 K and Charcoal (96 K in G.I./Copper plate Earth Station pit to provide low impedance ground in location of high soil resistivity as and when required and specified by the deptt .
Supplying & laying of 6 SWG G.I. earth from Earth Electrode (below G.L.) to electrical switch gears or electrical machineries including making necessary connection as approved, specified and directed by the deptt.
Supplying & laying of 25X5mm size G.I. strips drawn on surface from earth electrode to Electrical switch gears, machineries etc complete with supply of G.I. nuts & bolts, screws etc including riveting, soldering & making necessary connection as approved, specified and directed by the deptt.
Supplying & laying of 25X5mm size Copper strips drawn on surface from earth electrode to Electrical switch gears, machineries etc complete with supply of Brass nuts & bolts, screws etc including riveting, soldering & making necessary connection as approved, specified and directed by the deptt.
Supplying and installation and commissioning of vermin and dust proof totally enclosed double door cubical type compartmental floor mounting panel board of size 1.20 m ×1.00 m ×0.50 m made of 16 SWG1.66mm) thick CR sheet and 35 mm × 35 mm × 6 mm size angle and 35 mm ×6 mm flat iron having 4 nos legs at the bottom and G.I. Sheet reefing on the top complete painting with 2 coats of red oxide metal primer and 2 coats of enameled paint. The panel board is to be erected in 1:3:6 RCC pole foundation including excavation of trench and brick soling etc. complete neatly internal wiring done as specified and directed by the department comprising of the following electrical items. 1. 40 Amp 4 pole 415 Volt 50 Hz MCCB as incomer - 1 no 2. 32 Amp 2 pole open execution with HBC fuse SDFU unit as outgoing - 3 nos 3. 25 mm × 5 mm size 4 strip copper Bus-Bar- 1 set 4. 40 Amp 4 pole ON-OFF poser contactor - 1 No. 5. Surface mounting timer switch - 1 No. 6. 63 Amp bakelite HBC fuse kit-kat - 3 Nos
Supply and laying of following size PVC/XLPE insulated and PVC sheathed 1.1 KV G Solid Aluminium conductor up to 10 sq mm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armour (Aluminium for single core up to 70 sq mm balance Aluminium strip, Galvanised for cables up to 2x10 sq mm.3x10 sq mm,4x6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 sheathed, 650/1100V grade as per IS 7908(Part 1) 1988 armoured U.G. cable U.G. cable laid in ground/partially in air (as required for termination over ground including excavation of cable trench up to depth of 75cm, refilling, protective brick covering, Sand cushioning etc complete handling of surplus spoil, debris et to proper place as specified and directed by the deptt. (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make) 3 Core A2XWY A2XFY. 4.00 Sq.mm 3 Core armoured U.G. cable
Supply and laying of following size PVC/XLPE insulated and PVC sheathed 1.1 KV G Solid Aluminium conductor up to 10 sq mm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armour (Aluminium for single core up to 70 sq mm balance Aluminium strip, Galvanised for cables up to 2x10 sq mm.3x10 sq mm,4x6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 sheathed, 650/1100V grade as per IS 7908(Part 1) 1988 armoured U.G. cable U.G. cable laid in ground/partially in air (as required for termination over ground including excavation of cable trench up to depth of 75cm, refilling, protective brick covering, Sand cushioning etc complete handling of surplus spoil, debris et to proper place as specified and directed by the deptt. (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make) 3 Core A2XWY A2XFY. 6.00 Sq.mm 3 Core armoured U.G. cable
Supply and laying of following size PVC/XLPE insulated and PVC sheathed 1.1 KV G Solid Aluminium conductor up to 10 sq mm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armour (Aluminium for single core up to 70 sq mm balance Aluminium strip, Galvanised for cables up to 2x10 sq mm.3x10 sq mm,4x6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 sheathed, 650/1100V grade as per IS 7908(Part 1) 1988 armoured U.G. cable U.G. cable laid in ground/partially in air (as required for termination over ground including excavation of cable trench up to depth of 75cm, refilling, protective brick covering, Sand cushioning etc complete handling of surplus spoil, debris et to proper place as specified and directed by the deptt. (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make) 3 Core A2XWY A2XFY. 10.00 Sq.mm 3 Core armoured U.G. cable
Supply and laying of following size PVC/XLPE insulated and PVC sheathed 1.1 KV G Solid Aluminium conductor up to 10 sq mm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armour (Aluminium for single core up to 70 sq mm balance Aluminium strip, Galvanised for cables up to 2x10 sq mm.3x10 sq mm,4x6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 sheathed, 650/1100V grade as per IS 7908(Part 1) 1988 armoured U.G. cable U.G. cable laid in ground/partially in air (as required for termination over ground including excavation of cable trench up to depth of 75cm, refilling, protective brick covering, Sand cushioning etc complete handling of surplus spoil, debris et to proper place as specified and directed by the deptt. (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make) 3 & 1/2 Core A2XWY A2XFY. 25.00 Sq. mm.3 & 1/2 Core armoured U.G. cable
Supply and laying of following size PVC/XLPE insulated and PVC sheathed 1.1 KV G Solid Aluminium conductor up to 10 sq mm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armour (Aluminium for single core up to 70 sq mm balance Aluminium strip, Galvanised for cables up to 2x10 sq mm.3x10 sq mm,4x6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 sheathed, 650/1100V grade as per IS 7908(Part 1) 1988 armoured U.G. cable U.G. cable laid in ground/partially in air (as required for termination over ground including excavation of cable trench up to depth of 75cm, refilling, protective brick covering, Sand cushioning etc complete handling of surplus spoil, debris et to proper place as specified and directed by the deptt. (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make) 3 & 1/2 Core A2XWY A2XFY. 70.00 Sq. mm.3 & 1/2 Core armoured U.G. cable
Supply and laying of following size PVC/XLPE insulated and PVC sheathed 1.1 KV G Solid Aluminium conductor up to 10 sq mm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armour (Aluminium for single core up to 70 sq mm balance Aluminium strip, Galvanised for cables up to 2x10 sq mm.3x10 sq mm,4x6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 sheathed, 650/1100V grade as per IS 7908(Part 1) 1988 armoured U.G. cable U.G. cable laid in ground/partially in air (as required for termination over ground including excavation of cable trench up to depth of 75cm, refilling, protective brick covering, Sand cushioning etc complete handling of surplus spoil, debris et to proper place as specified and directed by the deptt. (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make) 3 & 1/2 Core A2XWY A2XFY. 120.00 Sq. mm.3 & 1/2 Core armoured U.G. cable
Supply and laying of following size PVC/XLPE insulated and PVC sheathed 1.1 KV G Solid Aluminium conductor up to 10 sq mm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armour (Aluminium for single core up to 70 sq mm balance Aluminium strip, Galvanised for cables up to 2x10 sq mm.3x10 sq mm,4x6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 sheathed, 650/1100V grade as per IS 7908(Part 1) 1988 armoured U.G. cable U.G. cable laid in ground/partially in air (as required for termination over ground including excavation of cable trench up to depth of 75cm, refilling, protective brick covering, Sand cushioning etc complete handling of surplus spoil, debris et to proper place as specified and directed by the deptt. (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make) 4 Core A2XWY A2XFY. 10.00 Sq.mm 4 Core armoured U.G. cable
Supply and laying of following size Solid Aluminium conductor up to 10 sq mm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armour (Aluminium for single core up to 70 sq mm balance Aluminium strip, Galvanised for cables up to 2x10 sq mm.3x10 sq mm,4x6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 sheathed, 650/1100V grade as per IS 7908(Part 1) 1988, LT armoured U.G. cable laid in pucca flooring, road crossing, drain crossing as per site requirement and partially in air to connection as approved by the Depts. the control switch, through medium duty G.I. pipe (Tata/ Nezone make or equivalent as approved by the Deptt) bend and socket including excavation and refilling the trench and making good damage done as specified and directed by the deptt. (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make) Core - 3 A2XWY A2XFY 4.00 Sq.mm 3 Core U.G. cable in 25mm dia medium duty G.I. pipe
Supply and laying of following size Solid Aluminium conductor up to 10 sq mm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armour (Aluminium for single core up to 70 sq mm balance Aluminium strip, Galvanised for cables up to 2x10 sq mm.3x10 sq mm,4x6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 sheathed, 650/1100V grade as per IS 7908(Part 1) 1988, LT armoured U.G. cable laid in pucca flooring, road crossing, drain crossing as per site requirement and partially in air to connection as approved by the Depts. the control switch, through medium duty G.I. pipe (Tata/ Nezone make or equivalent as approved by the Deptt) bend and socket including excavation and refilling the trench and making good damage done as specified and directed by the deptt. (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make) Core - 3 A2XWY A2XFY 6.00 Sq.mm 3 Core U.G. cable in 32mm dia medium duty G.I. pipe
Supply and laying of following size Solid Aluminium conductor up to 10 sq mm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armour (Aluminium for single core up to 70 sq mm balance Aluminium strip, Galvanised for cables up to 2x10 sq mm.3x10 sq mm,4x6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 sheathed, 650/1100V grade as per IS 7908(Part 1) 1988, LT armoured U.G. cable laid in pucca flooring, road crossing, drain crossing as per site requirement and partially in air to connection as approved by the Depts. the control switch, through medium duty G.I. pipe (Tata/ Nezone make or equivalent as approved by the Deptt) bend and socket including excavation and refilling the trench and making good damage done as specified and directed by the deptt. (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make) Core - 3 A2XWY A2XFY 10.00 Sq.mm 3 Core U.G. cable in 32mm dia medium duty G.I. pipe
Supply and laying of following size Solid Aluminium conductor up to 10 sq mm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armour (Aluminium for single core up to 70 sq mm balance Aluminium strip, Galvanised for cables up to 2x10 sq mm.3x10 sq mm,4x6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 sheathed, 650/1100V grade as per IS 7908(Part 1) 1988, LT armoured U.G. cable laid in pucca flooring, road crossing, drain crossing as per site requirement and partially in air to connection as approved by the Depts. the control switch, through medium duty G.I. pipe (Tata/ Nezone make or equivalent as approved by the Deptt) bend and socket including excavation and refilling the trench and making good damage done as specified and directed by the deptt. (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make) Core - 3 & 1/2 A2XWY A2XFY 25.00 Sq.mm 3&1/2 Core U.G. cable in 40mm dia medium duty G.I. pipe
Supply and laying of following size Solid Aluminium conductor up to 10 sq mm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armour (Aluminium for single core up to 70 sq mm balance Aluminium strip, Galvanised for cables up to 2x10 sq mm.3x10 sq mm,4x6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 sheathed, 650/1100V grade as per IS 7908(Part 1) 1988, LT armoured U.G. cable laid in pucca flooring, road crossing, drain crossing as per site requirement and partially in air to connection as approved by the Depts. the control switch, through medium duty G.I. pipe (Tata/ Nezone make or equivalent as approved by the Deptt) bend and socket including excavation and refilling the trench and making good damage done as specified and directed by the deptt. (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make) Core - 3 & 1/2 A2XWY A2XFY 70.00 Sq.mm 3&1/2 Core U.G. cable in 50 mm dia medium duty hot dip galvanised pipe (AKG or equivalent as approved by the Deptt.)
Supply and laying of following size Solid Aluminium conductor up to 10 sq mm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armour (Aluminium for single core up to 70 sq mm balance Aluminium strip, Galvanised for cables up to 2x10 sq mm.3x10 sq mm,4x6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 sheathed, 650/1100V grade as per IS 7908(Part 1) 1988, LT armoured U.G. cable laid in pucca flooring, road crossing, drain crossing as per site requirement and partially in air to connection as approved by the Depts. the control switch, through medium duty G.I. pipe (Tata/ Nezone make or equivalent as approved by the Deptt) bend and socket including excavation and refilling the trench and making good damage done as specified and directed by the deptt. (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make) Core - 3 & 1/2 A2XWY A2XFY 120.00 Sq.mm 3&1/2 Core U.G. cable in 65mm dia medium duty hot dip galvanised pipe (AKG or equivalent as approved by the Deptt.)
Supply and laying of following size Solid Aluminium conductor up to 10 sq mm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armour (Aluminium for single core up to 70 sq mm balance Aluminium strip, Galvanised for cables up to 2x10 sq mm.3x10 sq mm,4x6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 sheathed, 650/1100V grade as per IS 7908(Part 1) 1988, LT armoured U.G. cable laid in pucca flooring, road crossing, drain crossing as per site requirement and partially in air to connection as approved by the Depts. the control switch, through medium duty G.I. pipe (Tata/ Nezone make or equivalent as approved by the Deptt) bend and socket including excavation and refilling the trench and making good damage done as specified and directed by the deptt. (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make) Core - 4 A2XWY A2XFY 10.00 Sq.mm 3 Core U.G. cable in 32mm dia medium duty G.I. pipe
Supplying including installation of cast iron cable marker as specified and directed by the deptt.
Supply including fitting and fixing of 1.1 KV PVC/XLPE cable INDOOR/OUTDOOR end termination Kits (Raychem RPG make) HEAT SHRINK TYPE including all accessories for the following sizes including testing and commissioning as specified and directed by the Deptt. 70-150 Sq.mm., 3/ 3.5/ 4 Core cable.
Supplying including installation of the Octagonal poles shall be designed to withstand the maximum wind speed of 169 km/hr. The top loading i.e. area and weight of fixtures are to be considered to calculate maximum deflection of the poles and the same shall meet the requirement of BS:5649 Part VI 1982. The pole shaft shall have octagonal cross section and shall be continuously tapered with single longitudinal welding. There shall not be any circumferential welding of the pole shaft. The welding of the pole shaft shall be done by Submerged Welding process. All octagonal pole shafts shall be provided with the rigid flange plate of suitable thickness with provision for fixing 4 foundation bolts. The base plate shall be fillet welded to the pole shaft at two locations i.e. from inside and outside. The welding shall be done as per process approved by Third Party Inspection agency. (BAJAJ/ PHILIPS/ VALMONT/ PARUTHI ENGR/Nezone make) Pole Type BOP or equivalent-3030 Height 3 m The materials of the pole as follows : Conforming to grade S355JO Conforming to grade S355JO, Base Plate :- Fe 410 Conforming to IS 226/ IS 2062, Foundation Bolts :- 6.8 Gr. As per IS 1367, Pole Sections:- The Octagonal Poles shall be in single piece with single longitudinal welding join. Galvanization :- The poles shall be hot dip galvanized as per IS 2629 / IS 2633 / IS 4759 standards with average coating thickness of 65 micron. The galvanizing shall be done in single dipping. Door opening :- The Octagonal poles shall have door of approximate 500 mm length at the elevation of 500 mm from the base plate. The door shall be vandal resistance and shall be weather proof to ensure safety of inside connection as approved by the Depts.. The door shall be flush with the exterior surface and shall have suitable locking arrangement. The pole shall be adequately strengthened at the location of the door compensate for the loss in section. There shall also be suitable arrangement for the purpose of earthing, Smart pack Junction box with 6 MCB & Terminals for mounting inside base compartment of Pole. . Size of the pole Diameter: Did. 130mm, Sheet Thickness :- 3mm, Base Plate Dimensions :- (L x BxT x 220mm x 220mm x 12mm, Foundation Bolt Size:- (no. x dia.) 4 x 16 Dia, Pitch Circle Dia. (PC :- 200, Bolt Length:- 450, Projected Bolt Length :-80, Anchor plate thickness :- 4 mm, Pole Foundation :-The octagonal poles shall be bolted on a pre- cast foundation with a set of four foundation bolts for greater rigidity. Foundation :- The foundation shall be done with ( Earth work :- 2.04 cubic Meters.RCC :- 1:1.5 : 3 proportion 0.65 cubic metres. Steel:- 22.43 Kg., Shuttering4.32 Square metres. Shuttering :- 4.32 square metres. = 22.43 Kg.
Supplying, erection, testing and commissioning of 20 M high mast system with its accessories such as foundation bolts manufactured from special steel along with nuts, washers, anchor plates and templates, non-integral flood light luminaries with 2 nos 400 W HPSVT lamps and its control gear boxes (Bajaj/ Crompton/ Wipro/ HPL/ Solar/ Philips make) twin dome aviation obstruction lights of with Neon spiral lamps, control panel housing 32 A TPN MCB incomer, single dial timer contactor circuit for the automatic control of luminaries, outgoing terminals and control circuit for the power tool motor. Mast shaft shall be in two sections, hot dip galvanised and suitable for wind velocity as per IS 875. It shall also include accessories for high mast including head frame, steel rope 6 mm dia ( 7 / 19 construction) , trailing cable, double drum winch, Galvanised Lantern carriage arrangement suitable for 8 luminaries symmetrically & its control gear boxes and lightning finial. The mast shall be erected on suitable shallow foundation with 1 : 2 : 4 concrete for the high mast considering the safe soil bearing capacity at site as 10 T / Sq meter at 2 metre depth. The mast shall have an integral power tool installed inside the base compartment for its operation.(BAJAJ/ SRB/VALMONT/ PHILIPS/ PARUTHI ENGR make) Supply of foundation bolts manufactured from special steel along with nuts, washers, anchor plates and templates. Supply of 8 Nos non-integral flood light luminaries with two nos 400 W HPSVT lamps and its control gear boxes. Supply of twin dome aviation obstruction lights of type BJAOL 1 with Neon spiral lamps. Supply of control panel housing 32 A TPN MCB incomer, single dial timer contactor circuit for the automatic control of luminaries, outgoing terminals and control circuit for the power tool motor. B. Erection Construction of suitable shallow foundation with 1 : 2 : 4 concrete for the high mast considering the safe soil bearing capacity at site as 10 T / Sq meter at 2 metre depth with all materials and labour. Erection of the high mast with the help of suitable equipments and Wiring of luminaries with all Wiring materials and labour. provision of GI pipe earthing for high mast with 2.5 m long 40 mm dia GI pipe including connection as approved by the Deptt.)to high mast terminal with 25 x 3 mm GI strip with all materials and labour. ( 2 nos per mast require . Erection of the above panel on suitable foundation including all materials and labour.
Supplying including installation, connection as approved by the Deptt., testing and commissioning of CENTRIFUGAL MONOBLOCK PUMP SET complete as directed and specified by the deptt. 3 HP single Phase Centrifugal monoblock pump set (Crompton Greaves/ Aquatic/ CRI/ V-Guard make) 2900 rpm with DOL Starter ( Crompton Greaves/ Control & Switch Gear/ BCH/ L& T / Siemens make) .
Supplying including installation, connection as approved by the Deptt., testing and commissioning of SUBMERSIBLE PUMP SET 3 (Three Phase) with steel cable rope and submersible cable complete as directed and specified by the deptt. Three phase Submersible motor pump set (Texmo / Crompton Greaves/ Aquatic/ CRI/ V-Guar suitable for 100 mm bore well and above. 3 HP STAGE 7 to 40 with MCB controlled Submersible motor pump set control panel.
Supplying including installation, connection as approved by the Deptt., testing and commissioning of SUBMERSIBLE PUMP SET 3 (Three Phase) with steel cable rope and submersible cable complete as directed and specified by the deptt. Three phase Submersible motor pump set (Texmo / Crompton Greaves/ Aquatic/ CRI/ V-Guar suitable for 100 mm bore well and above. 5 HP STAGE 14 to 50 with MCB controlled Submersible motor pump set control panel.
Supplying, installation, testing and commissioning of pressure die cast powder coated aluminium alloy housing frosted PC diffuser, IP65/IP66 protection with build in LED of the following landscape luminarie ( POST TOP ) suitable for 38mm dia post top mounting applications including connections with 2.50 sq.mm 3core multistrand P.V.C. insulated round copper cable as required and directed by the department. [PTL] CROMPTON MAPLE CAT REF: LPTO-60-CDL/M
Supplying,installation,testing and commissioning of pressure die cast powder coated aluminium alloy housing frosted PC diffuser, IP65/IP66 protection of the following street light including connection with 2.5 Sq.mm. 3 core PVC insulated round copper conductor as required and as directed by the department. [STL] BRP 410 LED 094 CW HE MR FG S2 PSU GR
Supplying with fitting and fixing sheet steel cable junction box of size 40cm x 20cm x 15 cm made of 16 SWG thick MS Sheet with provision for hinge door and panel locking arrangement complete painted with 2 coats of metal primer and 2 coats of enamelled gloss paint of approved brand and manufacture to give an even shape including cleaning surface to remove of all dirt, dust and other foreign matter, the box is to be fitted on the bottom section of pole with minimum 165 mm dia 25 mm x 5mm size flat iron pole clamp complete with making necessary connection as directed consisting of the following electrical items. 6 amp "L" series SP MCB as outgoing - 2 Nos.
Supply, Installation antistatic rubber mat suitable for 1.1 KV Voltage grade
Supply, Fitting Fixing of Shock Treatment Chart
Supplying including installation, testing and commissioning of Water Cooled Jackson Diesel Generator set coupled to suitable alternator of 415 V, AC, 3-Phase 0.8 p.f. mounted on a 1) M.S. Fabricated base frame.,2) M.S. fuel tank of required capacity.,3) Residual Silencer.,4) AMF/Standard Control Panel.5) Suitable batteries with lead.,5) First fill of lube oil.,6) Acoustic Enclosure complete with all accessories as specified and directed by the department conforming to IS comprising the following Technical Specification.. (RANGE FROM 15 KVA TO 625 KV TECHNICAL DATA CJ100D5P GENERATOR SET SPECIFICATIONS 100/80 3. No. of Phases. 3 phase. 4. POWER FACTOR 0.8 LAG JACKSON ENGINE SPECIFICATION. 1. make). Cummins 2. Model. 6BTA5.9G5 3. No. of Cylinders. 6 4. Aspiration. TURBO CHARGED after COOLED 5. Cooling. Water Cooled. 6. Governor. Mechanical 7. Battery Capacity Rating. 12 Volt. 8. FUEL CONSUMPTION LTR/HR @ 75% LOAD 16.9 ALTERNATOR SPECIFICATION. 1. make). CGT (STAMFOR 2. Voltage Regulation. +/- 1.0% 3. Insulation. Class - H. 4. Standard Enclosure. IP 23 5. No. of Phases. 3 WITH STANDARD CONTROL PANEL
Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared.
Surface dressing of the ground including removing vegetation and in?equalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m.
Filling with available fly ash and earth (excluding rock) in trenches or embankment in layers (each layer should not exceed 15 cm), with intermediate layer of compacted earth (Soil density of 98%) after every four layers of compacted depth of fly ash, sides & top layer of filling shall be done with earth having total minimum compacted thickness 30 cm or as decided by Engineer -in-charge, including compacting each layer by rolling/ ramming and watering, all complete as per drawing and direction of Engineer -in - charge.
Providing, laying and positioning Standard single cell precast box culverts along with wing walls, parapet walls, etc. including necessary earthwork in excavation in all type of soil/ rock and refilling, transportation, erection, jointing by grouting, etc complete as per the Assam Standard Culverts ASC ( 1 cell x 1.0 m x 1.0 m) drawings and Specifications and as directed by the Engineer.
Dressing & profiling the existing WBM/Granular surface layer of the road from edge to edge of the existing carriage way, fitting low spots and ravelled stretches by providing additional material of same type as that of the existing top surface layer, cambering, watering, rolling with 8—10 tonne roller to obtain specified compaction etc to obtain a uniform formation surface with cross fall from the road centre line to the outer edges of the existing embankment. Works to be carried out in accordance with MORT&H specification section 300 and as directed by the deptt. at sections where the top level of the subgrade of the existing road surface is not proposed to be raised by more than 100 mm. Roads having hard crust Carriage way (Paved Road).
Construction of Granular Sub-Base by providing well graded material spreading in uniform layers with motor grader on prepared surface mixing by mix in place method with rotovator at OMC and compacting with smooth wheel roller to achieve the desired density complete as per technical specification clause 401. For Grading-I material.
WBM GRADING 3 Providing ,Laying & spreading & compacting stone aggregate of specific size to water bound macadam specification including spreading in uniform thickness, hand packing,rolling with three wheel 80-100kN static roller in stages to proper grade and camber, applying and brooming ,crushable screening to fill up the interstices of coarse aggregate,watering and compacting to required density grading 3 as per technical specification clause 405. By Manual means.
Providing and Laying interlocking concrete block pavement(M-40) having thickness 80mm as per technical Specification clause 1504 complete including carriage. Including Edge Restraint
A provisional sum of Rs. 16,14,000.00 (Rupees Sixteen Lakhs Fourteen Thousand Only) for resettlement of existing temporary market sheds and ESMP requirements is provided and to be operated and expended in whole or in part as per the instruction of Engineer.
Purvattar Enterprise
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .