Loading…
Loading…
| # | Company | Amount |
|---|---|---|
| 1 | ₹24.0 Cr | ₹24.0 Cr |
| 2 | ₹25.7 Cr | ₹25.7 Cr |
| 3 | ₹27.7 Cr | ₹27.7 Cr |
| Sl No | Description | Qty | Unit | Amit Jain-Amit | shankara enterprises-Harihar | J P Construction Co-Jaiprakash |
|---|---|---|---|---|---|---|
| 1 | Excavation for all types and sizes of foundations, trenches and drains or for any other purpose including disposal of excavated stuff upto 1.5 m lift and lead upto 50m (at least 5m away from the excavated area), including dressing and leveling of pits.
1.1.1 In all types of soils. | 15,643.21 | cum | 200 ₹31,28,642 | 140 ₹21,90,049.4 Lowest | 250 ₹39,10,802.5 |
| 2 | In ordinary rocks. | 1,044.85 | cum | 600 ₹6,26,910 | 230 ₹2,40,315.5 Lowest | 500 ₹5,22,425 |
| 3 | Surface dressing of the ground including removing vegetation and making up undulations and in-equalities not exceeding 15 cms in depth/ height including disposal of rubbish upto 1.5 m lift and lead upto 50m (at least 5m away from the dressed area). | 43,215 | Square Meter | 5 ₹2,16,075 Lowest | 5 ₹2,16,075 Lowest | 10 ₹4,32,150 |
| 4 | Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth upto 30 cm measured at a height of 1 m above ground level and removal of rubbish upto a distance of 50 m outside the periphery of the area cleared. | 43,215 | Square Meter | 4 ₹1,72,860 | 2.5 ₹1,08,037.5 Lowest | 3.7 ₹1,59,895.5 |
| 5 | Extra for every additional lift of 1.5 m or part thereof.
1.6.1 All types of soils | 3,604.95 | cum | 50 ₹1,80,247.5 | 20 ₹72,099 Lowest | 150 ₹5,40,742.5 |
| 6 | Ordinary or hard rocks | 1,044.85 | cum | 100 ₹1,04,485 | 1 ₹1,044.85 Lowest | 150 ₹1,56,727.5 |
| 7 | Extra rate for quantity of work executed in or under water and/ or liquid mud including pumping out water. | 2,085.54 | cum | 100 ₹2,08,554 | 1 ₹2,085.54 Lowest | 51 ₹1,06,362.54 |
| 8 | Extra rate for lead for every 50m lead or part thereof and upto 150 m beyond 50 m free lead and 1.5 m free lift by manual means only.
1.9.1 For Soils | 4,649.79 | cum | 100 ₹4,64,979 | 1 ₹4,649.79 Lowest | 33 ₹1,53,443.07 |
| 9 | Pumping out water caused by springs tidal or river seepage, broken water main or drains and like during Excavation or during Excavation and laying of base concrete (volume to be calculated taking height from water level to bottom of pit and to be measured and paid) . | 3,109.59 | cum | 100 ₹3,10,959 | 1 ₹3,109.59 Lowest | 146 ₹4,54,000.14 |
| 10 | Open timbering in foundation trenches including strutting and shoring complete (measurements to be taken of the face area timbered.)
1.11.1 Depth not exceeding 1.5 M. | 3,149.39 | Square Meter | 100 ₹3,14,939.3 | 1 ₹3,149.39 Lowest | 178 ₹5,60,591.95 |
Tender Value
₹24.4 Cr
EMD Value
₹5 L
Closing Date
8 Jun 2026, 5:00 pmClosed
MR NITY GAJBHIYE
CE(Raipur)
CONSTRUCTION OF COMMUNITY HALL (CLUB HOUSE) AT RESIDENTIAL CAMPLEX OF SENIOR OFFICERS AT NAVA RAIPUR ATAL NAGAR SECTOR -18 I/C. ELECTRIFICATION WORK AT DISTT. RAPUR( B&R DIVISION , NAWA RAIPUR).
191099
NIT NO:260/TC/2026-27
RESTRICTED TENDER
WORKS
ITEM RATE
18 days
CE(Raipur)
Required Past Technical Experience: AS PER NIT
Required Financial Turnover (in INR): AS PER NIT
Required Bid Capacity (in INR): AS PER NIT
17 documents required · 17 mandatory
Public Works Department (PWD)
WORKS
MR NITY GAJBHIYE
RESTRICTED TENDER
ITEM RATE
A
CE(Raipur)
PWD Circle-1,Raipur
NAVA RAIPUR
120
18
No
712
191099
8 Jun, 2026 5:00:00 PM IST
11 Jun, 2026 10:00:00 AM IST
18 May, 2026 5:00:00 PM IST
NIT NO:260/TC/2026-27
CONSTRUCTION OF COMMUNITY HALL (CLUB HOUSE) AT RESIDENTIAL CAMPLEX OF SENIOR OFFICERS AT NAVA RAIPUR ATAL NAGAR SECTOR -18 I/C. ELECTRIFICATION WORK AT DISTT. RAPUR( B&R DIVISION , NAWA RAIPUR).
500000.00 INR
RTGS/CHALLAN (ONLINE) Internet Banking (ONLINE)
244157000.00
2
10 Jun, 2026 5:00:00 PM IST
244157000
AS PER NIT
AS PER NIT
AS PER NIT
0.00 INR
21d 16h 34m
17 documents required · 11 mandatory · 6 optional
₹0
₹5 L
8 Jun 2026
15 May 2026
11 Jun 2026
18 May 2026
8 Jun 2026
18 May 2026
10 Jun 2026
Excavation for all types and sizes of foundations, trenches and drains or for any other purpose including disposal of excavated stuff upto 1.5 m lift and lead upto 50m (at least 5m away from the excavated area), including dressing and leveling of pits. 1.1.1 In all types of soils.
In ordinary rocks.
Surface dressing of the ground including removing vegetation and making up undulations and in-equalities not exceeding 15 cms in depth/ height including disposal of rubbish upto 1.5 m lift and lead upto 50m (at least 5m away from the dressed area).
Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth upto 30 cm measured at a height of 1 m above ground level and removal of rubbish upto a distance of 50 m outside the periphery of the area cleared.
Extra for every additional lift of 1.5 m or part thereof. 1.6.1 All types of soils
Ordinary or hard rocks
Extra rate for quantity of work executed in or under water and/ or liquid mud including pumping out water.
Extra rate for lead for every 50m lead or part thereof and upto 150 m beyond 50 m free lead and 1.5 m free lift by manual means only. 1.9.1 For Soils
Pumping out water caused by springs tidal or river seepage, broken water main or drains and like during Excavation or during Excavation and laying of base concrete (volume to be calculated taking height from water level to bottom of pit and to be measured and paid) .
Open timbering in foundation trenches including strutting and shoring complete (measurements to be taken of the face area timbered.) 1.11.1 Depth not exceeding 1.5 M.
Open timbering in case of shaft, wells cesspit, manholes and like, including strutting, shoring etc. complete (measurements to be taken of face are timbered) 1.12.2 Depth exceeding 1.5 M. but not exceeding 3 M.
Filling from available excavated stuff (Excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20cm in depth consolidating each deposited layer by ramming and watering with a lead upto 50 M. and lift upto 1.5 M.
Providing and filling in plinth with sand/ Crusher dust and hard moorum under floor in layers not exceeding 20cm in depth consolidating each deposited layer by ramming and watering, including dressing etc. complete.
Supplying chlorpyrifos/ Lindane emulsifiable concentrate of 20% in sealed containers including delivery as specified.
Diluting chemical emulsion (chlorpyrifos/ lindane) in water as per manufacturers recommendation and injecting for pre-constructional curative cum preventive anti-termite treatment:(Five year service guarantee bond to be signed by contractor) 1.25.1 Surface treatment by spreading emulsion under floor, over the plinth area before laying base concrete @ 5 litres / sqm
Treatment of inside of plinth masonry wall on using diluted chemical emulsion @ 1.5 litre per hole, including drilling 12 mm diameter holes in plinth wall below plinth protection at the interval of 300 mm and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand).
Treatment of outer side of plinth masonry wall using diluted chemical emulsion @ 1.5 litre per hole, including drilling 12 mm diameter holes in plinth wall at the junction of floor at the interval of 300 mm and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand).
Carriage by mechanical transport upto 5 km lead: 1.26.1 Earth
Providing and fixing form work including centring, shuttering, strutting, staging, propping bracing etc. complete and including its removal at all levels, for: 2.1.1 Foundations, footings, bases of columns plinth beam, curtain wall in any shape and size and all type of wall below plinth level.
Wall of any thickness including attached pilasters, buttresses etc. in super structure.
Window sills, anchor blocks, string course, bends, copings, bed plates and like.
Edge of slab, breaks in floor and walls upto 200mm.
Columns, Pillars, Piers and likes- rectangular or square in shape
Columns, beams & walls- circular or any other geometrical shape other than square and rectangular in all sizes
Suspended floors, roofs, access platform, balconies (plain surfaces) and shelves (cast in situ)
Beams, lintels, cantilevers & walls
Arches, domes and likes, exceeding 6 M. span
Weather shade, chhajja, Cornices and mouldings
Stair cases of all types excluding spiral and folded plate type, including risers and landings
Extra for additional height every 1m or part thereof where height of staging for form work exceeds 4.0 metre with adequate bracing, propping etc at all levels, for suspended floor, roof, landing, beam and balcony. (only plan area is to be measured):
Extra for providing fixing and removing of propping from lower floor upwards for the concreting. Propping should be provided two floors below. The props of lower floor must be 50% of the props of the floor above including wedging etc. complete. In case propping is done in one floor below, only half the rate shall be paid.
Providing and laying nominal mix plain cement concrete with crushed stone aggregate using concrete mixer in all works upto plinth level excluding cost of form work. 3.1.2 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size).
1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40mm nominal size).
1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 40mm nominal size).
Providing and laying design mix reinforced cement concrete with crushed graded stone aggregate 20mm nominal size using batching plant, transit mixer and concrete pump, in all works upto plinth level excluding cost of form work. 3.3.2 M-25 Grade
Extra for laying PCC/RCC of any grade in superstructure above plinth level for every floor or part thereof in addition to rate for foundation and plinth: Ground Floor
Extra for laying PCC/RCC of any grade in superstructure above plinth level for every floor or part thereof in addition to rate for foundation and plinth: First Floor
Extra for laying PCC/RCC of any grade in superstructure above plinth level for every floor or part thereof in addition to rate for foundation and plinth: Second Floor
Extra for laying PCC/RCC of any grade in superstructure above plinth level for every floor or part thereof in addition to rate for foundation and plinth: Terrace Floor
Extra for precast PCC/ RCC work of any mix including form work, hoisting and fixing in Cement Mortar. 1:2 (1 Cement : 2 coarse sand) and finishing with cement plaster in Cement Mortar 1:3 (1 Cement : 3 coarse sand) but excluding reinforcement.
Extra for laying PCC/ RCC, in or under water or liquid mud including cost of pumping or bailing out of water and removing slush etc. complete:
Providing and placing in position reinforcement for R.C.C. work including straightening, cutting, bending, binding etc. complete as per drawings including cost of binding wire in foundation and plinth all complete: 3.12.1 Thermo-Mechanically treated bars FE 415
Thermo-Mechanically treated bars FE 500D
Providing and laying damp proof course (upto 50mm thick) with plain cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded crushed stone aggregate 20mm nominal size) including form work.
Providing and mixing water proofing material in PCC/ RCC work in the proportion recommended by the manufacturer.
Applying a coat of hot bitumen VG-10 using @ 1.7kg/ sqm on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil.
Providing and fixing aluminium strip 1.60 mm thick on expansion joints with iron screws as per design to match the colour, shade of wall treatment .
Providing and fixing in expansion joint pre moulded cross linked polymer based filler as per IS:1838 (part III) of approved make including cutting to required size and shape etc complete.
Providing and applying for hermetically water proof sealing of vertical / horizontal expansion joint with approved make Poly Sulphide Sealant compound (two component elastomeric sealant) having 80% tensile modulus elongation, proper bonding with building surface complete with cleaning and preparing of building surface, applying polymer solvent primer, providing and fixing PU back up rod of suitable dia in expansion joint for core making, filling with Poly Sulphide Sealant (Sealant filling depth should be minimum half of the joint gap), finishing and smoothing the surface etc complete. 3.24.3 For gap 50 mm wide
Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of WC, kitchen and the like consisting of: i) 1st course of applying cement slurry @ 4.4 Kg/sqm mixed with water proofing compound conforming to IS 2645 including rounding off junction of vertical and horizontal surface. ii) 2nd course of 20mm cement plaster 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound including rounding off junction of vertical and horizontal surface. iii) 3rd course of applying blown or residual bitumen applied hot @ 1.7 Kg. per sqm of area. iv) 4th course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 Kg. per sqm of area.
Grading roof for water proofing treatment with: 4.13.1 Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size
Cement mortar 1:3 (1 cement : 3 coarse sand)
Brick work with modular fly-ash lime bricks (FaLG Bricks) confirming to IS:12894-2002 of class designation 4.0 in oundation and plinth in: 7.5.4 Cement Mortar 1:6 (1 cement : 6 coarse sand)
Extra for brick work in superstructure above plinth level for every floor or part thereof in addition to rate for foundation and plinth: Ground Floor
Extra for brick work in superstructure above plinth level for every floor or part thereof in addition to rate for foundation and plinth: First Floor
Extra for brick work in superstructure above plinth level for every floor or part thereof in addition to rate for foundation and plinth: Second Floor
Extra for brick work in superstructure above plinth level for every floor or part thereof in addition to rate for foundation and plinth: Terrace Floor
Half brick thick brick masonry with fly-ash lime bricks (FaLG Bricks) confirming to IS:12894-2002 of class designation 4.0 in superstructure above plinth level upto plinth level 7.11.2 Cement Mortar 1:4 (1 cement : 4 coarse sand)
Extra for half brick work in superstructure above plinth level for every story or part thereof in addition to rate for upto plinth level Ground Floor
Extra for half brick work in superstructure above plinth level for every story or part thereof in addition to rate for upto plinth level First Floor
Extra for half brick work in superstructure above plinth level for every story or part thereof in addition to rate for upto plinth level Second Floor
Extra for providing and placing in position hopping 25x1.60 mm or 2 Nos 6mm dia MS bars reinforcement at every third course of half brick masonry.
Providing and laying AAC Autoclaved aerated concrete block confirming to IS: 2185 (Part-3)-1984) in block masonry with AAC blocks of width 100/ 200mm height 200/250/300mm, length 400/500/600 mm (approved sizes) with cement mortar 1 :6 (1 Cement :6 coarse sand) in superstructure. AAC blocks should have specific gravity 0.6 to 0.65 and crushing strength should not be less than 3 N/ sqmm (testing as per IS: 6441 - 1972).
Providing wood work in frames of doors, windows, clerestory windows and other frames wrought framed and fixed in position. 8.1.1 Teak wood
Providing and fixing Dash fastener (for fixing door/ window frames) on C.C. / R.C.C./ Brick masonry surface backing including drilling necessary holes and the cost of bolt etc complete. 8.4.3 Dash fastener 12x100mm
Extra for double leaf shutter instead of single leaf.
Providing and fixing lipping with second class teak wood lipping on all edges of shutters. 8.18.3 35 x 6 mm size
Providing and fixing heavy duty stainless steel pipe for curtain/ cloth hanging with two stainless steel brackets in wooden pelmet or wardrobe or any other space including screws and or plastic rawl plugs etc. wherever necessary. 8.45.2 With 25 mm dia pipe
Providing and fixing bright finished brass sliding door bolt with nuts and brass polished MS screws complete: 8.60.1 300x16mm
Providing and fixing brass door latch with brass polished MS screws complete: 8.61.1 300x16x5 mm
Providing and fixing bright finished brass tower bolts (barrel type) with brass polished MS screws complete: 8.62.1 250x10mm
Providing and fixing bright finished brass door handles with brass polished MS screws complete: 8.65.1 125 mm
Providing and fixing bright finished brass hanging door stopper with necessary brass finished MS steel screws complete.
Providing and fixing factory made P.V.C. door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet mitred at corners and joined with 2 Nos of 150mm long brackets of 15x15mm M.S. square tube, the vertical door profiles to be reinforced with 19x19mm M.S. square tube of 19 gauge, EPDM rubber gasket weather seal to be provided through out the frame. The door frame to be fixed to the wall using M.S. screws of 65/100mm size complete as per manufacturers specification and direction of Engineer-in-Charge.
Providing and fixing 30mm thick factory made panel PVC door shutter consisting of frame made out of M.S. tubes of 19 gauge thickness and size of 19mm x 19mm for styles and 15x15mm for top & bottom rails. M.S. frame shall have a coat of steel primers of approved make and manufacture. M.S. frame covered with 5mm thick heat moulded PVC 'C' channel of size 30mm thickness, 70mm width out of which 50mm shall be flat and 20mm shall be tapered in 45degree angle on either side forming styles; and 5mm thick, 95mm wide PVC sheet out of which 75mm shall be flat and 20mm shall be tapered in 45 degree on the inner side to form top and bottom rail and 115mm wide PVC sheet out of which 75mm shall be flat and 20mm shall be tapered on both sides to form lock rail. Top, bottom and lock rails shall be provided either side of the panel. 10mm (5mm x 2 ) thick, 20mm wide cross PVC sheet be provided as gap insert for top rail & bottom rail. paneling of 5mm thick both side PVC sheet to be fitted in the M.S. frame welded/ sealed to the styles & rails with 7mm (5mm+2mm) thick x 15mm wide PVC sheet beading on inner side, and joined together with solvent cement adhesive. An additional 5mm thick PVC strip of 20mm width is to be stuck on the interior side of the 'C' Channel using PVC solvent adhesive etc. complete as per Manufacturer’s specification including 3 nos ISI marked stainless steel hinges of size 100x58x1.9 mm complete. (for W.C. and bathroom door shutter). 8.152.2 Both side Pre-laminated panel PVC door shutter
Providing and fixing IS: 3564 marked aluminium die cast body tubular type universal hydraulic door closer with necessary accessories and screws etc complete.
Structural steel work riveted or bolted or welded in built-up sections, trusses and frames work upto a height of 5m above plinth level, including cutting, hoisting, fixing in position and applying a priming coat of red oxide zinc chromate primer.
Steel work in tubular (round, square or rectangular hollow tubes etc.) structure in built-up sections, trusses and frame work including cutting, hoisting, fixing in position upto a height of 5m above plinth level, consisting of columns trusses, roof and bottom purlins, base plate, holding down bolts, wind ties bracing (if required), bolts, nuts and washers for fastening etc. complete with applying a priming coat of red oxide zinc chromate primer. 9.3.2 Electric resistance or induction butt welded tubes Grade-300
Extra for curvature in making steel work in tubular structure in built-up sections, trusses and frame work
Extra for hoisting trusses and placing in position over height above 5m for every 2.5 m height or part thereof.
Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2mm and braced with flat iron diagonals 20x5mm size with top and bottom rails of T-iron 40x40x6mm with 38mm steel pulleys complete with bolts, nuts, locking arrangement stoppers, handles including applying a priming coat of red oxide zinc chromate primer.
Providing and fixing steel door/ window with M.S. sheet 1mm thick, frame of angle iron, diagonal braces of angle/ flat iron of suitable size, 3.00 mm M.S. gusset plates at junctions and corners, all necessary fittings complete including applying a priming coat of red oxide zinc chromate primer.
Providing and fixing M.S. grill of approved pattern made of M.S. flats or square or round bars welded to steel frame of windows etc. including applying a priming coat welded to frame with all necessary fitting complete including applying a priming of red oxide zinc chromate primer.
Providing and fixing stainless wire gauge of average width of aperture 1.56mm with wire of 0.35mm to existing steel door, window shutter frames with necessary M.S. strip beading etc. complete.
Providing and fixing M.S. fan clamp/hook for ceiling fan made out of 16 mm dia M.S. bar bent to shape with hooked ends in R.C.C. slabs, beams during laying including painting the exposed portion of loop.
Providing and fixing in position chain linked steel wire fabric made of 4 mm dia G.I. wire of required width in mesh to concrete/ wooden angle iron posts including securing and screwing with 2 mm dia wire, G.I. staples, G.I.U-nails or steel pins etc., complete. 9.43.1 Aperture 50x50 mm
providing and placing in position angle iron post and strut of required size including bottom to be split and bent at right angle in opposite direction for required length and drilling holes up to 10 mm dia as per requirement including priming coat with red oxide zinc chromate primer and placing the post / strut in cement
Providing and fixing aluminium work for doors, windows, ventilators and partitions made out of extruded aluminium standard sections (main section with minimum 1.5mm thickness) conforming to IS: 733, IS: 1285 mitred and jointed mechanically including aluminium cleats, neoprene weather stripping gasket beveled edge beading, screws duly fixed in wall/ floor with fixing clips or hold fasteners or bolts and nuts as required aluminium sections shall be anodized transparent or dyed to approved shade according to IS: 1868, minimum anodic coating shall be of grade AC-15. (Glazing to be paid for separately: 9.47.1 For fixed portion @ 8.5kg / sqm
For shutter of doors, windows & ventilators including providing and making provision for fixing of fitting wherever required including the cost of PVC/ neoprene gasket required (Fittings shall be paid for separately).
Extra for polyester powder coated (minimum 50 micron) aluminium sections instead of anodized.
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with PVC/ neoprene gasket etc. complete. (Cost of aluminium snap beading shall be paid in basic item): 9.51.1 With float glass panes of 4 mm thickness
Providing stainless steel railing/ grill made of S.S. flats, hollow S.S. pipe or square/ rectangular sections of approved design fixing in stair case, balcony or other places with metal fasteners and stainless steel bolts etc complete. 9.57.2 SS Grade 304
Extra for providing and fixing tinted glass panes in aluminium door, window, ventilator shutters and partitions instead of float glass. 9.58.1 4 mm thickness
Designing, providing and fixing aluminium frame work made of special aluminium section on building face with M.S. angle iron brackets fixed on RCC structure with S.S. hold fasteners, including providing and fixing two sided structural adhesive tape of appropriate grade (NORTON or equivalent), on aluminium sections for fixing aluminium/ glass panel,sealing on periphery of frame work, by providing EPDM gasket, silicon weather sealant between aluminium frame and building structure including hire charges of double scaffolding complete.
Providing and fixing aluminium composite panels in approved panel sizes, thickness and shape on aluminium frame work on face of building. (Frame to be paid separately ) 9.61.2 4mm thick
Providing and fixing laminated glass sheet of 8.76mm thickness in approved sizes on aluminium frame work on face of building. (Frame to be paid for separately).
Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10mm and down grade) including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design :
Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1mx1mx650 micron thick (0.65mm), finished with 12mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement rounding the edge sand making and finishing the outlet complete.
Proving & fixing Acoustical Suspended Ceiling System made of size 595x595 mm and specified thickness as approved by Engineer-In-charge, in true Horizontal Level Suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanised @120 gsm/sqm, both side inclusive) consisting of main "T" Runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 thick (minimum) sheet, spaced at 1200mm center to center and cross "T" of size 24x38 mm made of 0.30 thick (minimum) sheet, 1200 mm long spaced between main "T" at 600mm center to center to form grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x38mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24mm and laying false ceiling tiles of approved texture in the grid, cutting/making, opening for services like diffusers, grills, light fitting, fixtures, smoke detectors etc whereever required. Main "T" rummer to be suspended from ceiling using GI slooted cleats of size 27x37x25x1.6mm fixed to ceiling with 12.5mm dia and 50 mm long dash fasterners, 4mm GI adjustable rods with galvanised butterfly level clips of size 85x30x0.8 mm spaced at 1200mm center to center along main "T", bottom exposed width of 24mm of all "T" sections shall be pre-painted with polyester paint, all complete for all heights as per specification drawings or as directed by Engineer-In-Charge.The tiles should have Humidity resistence(RH) of 99%, light Reflectance >83%, Thermal Conductivity K=0.052-0.57w/mk, colour white, fire performance UK class 0/Class 1(BS 476 pt-6 and 7) in module size of 600x600x16 mm with Bio Block coating on the face of the tile, suitable for green Building Application, with recycled content of 38-41%. ceiling height up 3.5 mt from adjacent floor level.extra height to be paid seprately. with 20 mm thick bevelled/tengular edged mineral fibre flase ceiling tile(NRC 0.7)
Proving & fixing Acoustical Suspended Ceiling System made of following tiles specified thickness as approved by Engineer-In-charge, in true Horizontal Level Suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanised @120 gsm/sqm, both side inclusive) consisting of main "T" Runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 thick (minimum) sheet, spaced at 1200mm center to center and cross "T" of size 24x38 mm made of 0.30 thick (minimum) sheet, 1200 mm long spaced between main "T" at 600mm center to center to form grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x38mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24mm and laying false ceiling tiles of approved texture in the grid, cutting/making, opening for services like diffusers, grills, light fitting, fixtures, smoke detectors etc whereever required. Main "T" rummer to be suspended from ceiling using GI slooted cleats of size 27x37x25x1.6mm fixed to ceiling with 12.5mm dia and 50 mm long dash fasterners, 4mm GI adjustable rods with galvanised butterfly level clips of size 85x30x0.8 mm spaced at 1200mm center to center along main "T", bottom exposed width of 24mm of all "T" sections shall be pre-painted with polyester paint, all complete for all heights as per specification drawings or as directed by Engineer-In-Charge.The tiles should have Humidity resistence(RH) of 99%, light Reflectance >83%, Thermal Conductivity K=0.052-0.57w/mk, colour white, fire performance UK class 0/Class 1(BS 476 pt-6 and 7) in module size of 600x600x16 mm with Bio Block coating on the face of the tile, suitable for green Building Application, with recycled content of 38-41%. ceiling height up 3.5 mt from adjacent floor level.extra height to be paid seprately.with perforated vinyl laminated gypsum panel of size 595x595x9mm thick,having 3x3mm square perforations @ 8.33mm pitch-10.2% open are tapered edge having 800 kgs/cum,weight 7.2 kg/sqm,NRC upto 0.75
Providing and making 6mm thick cement plaster of mix: 11.1.1 In Cement mortar 1:3 (1 cement : 3 fine sand)
Providing and making 12mm thick cement plaster of mix: 11.2.4 In Cement Mortar 1:6 (1 cement : 6 fine sand)
Providing and making 15mm thick cement plaster on the rough side of single or half brick wall of mix: 11.3.4 In Cement Mortar 1:6 (1 cement : 6 fine sand)
Neat Cement punning
Providing and making 18 mm thick cement plaster with under layer of 12mm thick cement plaster 1:5 (1 cement : 5 fine sand) finished with a top layer of 6mm thick cement plaster 1:3 (1 cement : 3 fine sand).
Extra for providing and mixing water proofing materials in cement plaster work in proportion as recommended by manufacturer
Providing and making 12mm thick plain cement mortar bands in cement mortar 1:4 (1 cement : 4 fine sand) per cm width: 11.31.1 Flush Bands
Sunk Bands
Raised Band
Making grove in cement plaster while plastering upto10 mm deep and 10 mm wide.
Providing and fixing chicken mesh weighting not less than 250 gms/ sqm as per IS : specification in the required idth with 40mm long steel nails on vertical and horizontal urface near R.C.C. and brick walls junctions including caffolding and all lead and lifts etc. complete before plastering upto 10mts in height.
Applying cement slurry on R.C.C. slab or cement concrete work using 2.75 kg/ sqm for receiving cement concrete floor including roughening cleaning etc complete.
Cement concrete flooring with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm) finished with a floating coat of neat cement. 12.3.1 40 mm thick
50 mm thick
Extra for providing and laying vitrified floor tiles with 2-5mm grove in between the tiles including grouting the grove with water resistant epoxy compound or with white cement and approved pigments etc. complete. 12.14.1 Size 600 x 600mm
Chequered terrazzo tiles 22 mm thick with graded marble chips of size upto 6mm in floors on 25mm thick bed of cement mortar 1:6 (1 cement : 6 coarse sand) jointed with neat cement slurry mixed with pigment to match the shade of tiles including grinding rubbing and polishing complete. 12.36.2 Medium shade using approximately. 50% white cement and 50% ordinary cement.
Extra for nosing in Granite stone for treads
15 mm thick Table rubbed polished Granite stone slab flooring laid over 20mm (Average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry including rubbing and polishing etc. complete. (Area of slab should be 0.50 sqm and above) 12.45.1 Granite stone grey /pink
Granite stone black
Granite stone lakha red/ shahi red
15 mm thick Table rubbed polished Granite stone slab in risers and treads of steps skirting dado and pillars laid on 12mm (Average) thick base of cement mortar 1:3 (1 cement : 3 coarse sand) and jointed with grey cement slurry including rubbing and polishing etc. complete (single stone is to be used for risers and treads of steps and width of stone for skirting and dado shall be equal to the height of skirting & dado and length of 1.0 m). 12.46.2 Granite stone black
Granite stone lakha red/ shahi red
25 mm thick KOTA stone slab flooring over 20mm (Average) thick base of cement mortar 1:4 laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including grinding rubbing and polishing etc. complete (Area of slab to be over 0.20 sqm and upto 0.50 sqm)
KOTA stone slab 25mm thick in risers and treads of steps, skirting dado and pillar laid in 12mm (Average) thick cement mortar 1:3 (1 cement : 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete. (single stone is to be used for riser and treads of steps and the width of stone for skirting and dado shall be equal to the height of skirting/ dado up to length of 1.0 M.)
Extra for nosing in steps and treads of Kota stone slab.
25mm thick Local RAJIM/ Red Flag stone slab flooring laid over 20mm (Average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid over & jointed with grey cement slurry mixed with pigments to match the shade of the stone i/c grinding, rubbing and polishing.
Extra for flooring of any type of stone/ tiles laid in approved design and pattern (Kite or other complicated).
Providing & laying 60mm thick precast interlocking concrete blocks of approved size (approx 305 sqcm) and shape/ pattern, over 40 mm thick average complete coarse sand bed with joints of 3mm thick filled by fine sand including leveling with surface vibrator, temping and sweeping etc. complete of minimum compressive strength of 250 kg/sq.cm 12.65.2 Pigment Coloured (rubber mould) precast interlock concrete blocks
Providing and fixing precast compressed plain cement concrete edge restraint block of size 500mmx250mmx60mm of compressive strength of 200kg per sq.cm manufactured by electro hydraulically operated block machine by excavated trench of 150mm depth, laid width wise etc. complete
38 mm thick parquet (wood blocks) flooring of teak wood laid over 25mm thick leveling layer of cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10mm nominal size) to be paid separately coated with thin layer of hot bitumen (blown type) @ 2.45 kg/ sqm including fixing blocks after dipping in hot bitumen (blown type) upto half depth planned, leveled, smooth and finished complete.
Extra for plaining the lower surface of wooden planking
Providing and fixing rectified glazed ceramic floor tiles of 1st quality conforming to IS : 15622-2017 of aprroved make,in all colours,shade over 20mm thick bed of cement mortar 1:3(1 cement :3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm including pointing in white cement mixed with matching pigment complete. 12.74.3 Size 600 x 600 mm Thickness 8 to 9 mm
Providing and fixing rectified glazed ceramic wall/dado tiles of 1st quality conforming to IS : 15622-2017 of aprroved make,in all colours,shades on wall and dados over 12mm thick bed of cement mortar 1:3(1 cement :3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm including pointing in white cement mixed with matching pigment complete. 12.75.2 Size 300 x 600 mm Thickness 7 to 8 mm
Providing and laying Glazed Vitrified wall/dado tiles GVT/ PGVT with digital print of random design with water absorption less than 0.08% and conforming to IS : 15622-2017 of 1st quality of approved make in all colours and shades and size mentioned below (+/- 10mm) for wall /daddo laid on 12mm thick cement mortar 1:4 (1 cement : 4 coarse sand) including grouting the joints with white cement and matching pigments etc. complete. 12.77.2 Size 800 x 800 mm thickness 9 to 10 mm
Providing and laying DOUBLE/ MULTI CHARGE (minimum 2.0mm thick layer) VITRIFIED floor tiles with water absorption less than 0.05% and conforming to IS : 15622-2017 of 1st quality of approved make in all colours and shades and size mentioned below (+/- 10mm), laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) including grouting the joints with white cement and matching pigments etc. complete.. 12.79.2 Size 800 x 800 mm thickness 10 to 12 mm
Size 1000 x 1000 mm thickness 10 to 12 mm
Size 1200 x 1200 mm thickness 10 to 12 mm
15mm thick Granite work (machine cut, table rubbed & mirror polished) for kitchen platform, vanity counters, window sills and similar locations of required size laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand) including joints treated with white cement mixed with matching pigment including rubbing and polishing to edge moulding to give high gloss finish. 13.6.2 Granite stone black
Providing and fixing 15mm thick Granite (machine cut, table rubbed & mirror polished on both sides) for partition curtain in toilets or similar locations of required size in wall with cement mortar 1:4 (1 cement : 4 coarse sand) including cutting chase in wall and joint with wall treated with white cement mixed with matching pigment including rubbing and polishing to edge moulding to give high gloss finish. 13.17.1 Granite stone grey/pink
Extra for providing edge moulding to 15mm thick stone counters, vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. 13.19.2 Granite work
Extra for making opening of required size & shape for wash basins/ kitchen sink in kitchen platform, vanity counters and similar location in marble/Granite/stone work including making necessary holes for pillar taps etc. including rubbing and polishing of cut edges etc. complete.
Mirror polishing on marble work/ Kota stone/ Granite work where ever required to give high gloss finish complete. 13.22.1 On walls/ Floor
Providing and fixing one side polished 25 mm thick RAJIM SAND STONE shelves fixed in walls in cement mortar 1:3 (1 cement : 3 coarse sand) including finishing complete. 13.24.1 One side polished
Preparation of wall surface by Wall Punning applying a coat of putty comprising of chalk mitti, varnish and white lead in ratio 2½:1:1 (2½ kg chalk mitti : 1 litre varnish : 1 kg white lead) respectively, sand papering and making the surface smooth up to 20mm thickness. with all tools , tackles and labour etc. complete for the work. (Only for item such as pasting wall paper etc.)
Providing and applying water proofing cement paint minimum 2 coats applied @ 3.84 kg/10 sqm up to required finish as per relevant IS code 5410:2013 of required shade (product such as Snowcem plus, J.K. Shri Cement paints, Century Cement Paints, Apex paints, Maxcoat cement paint) with all tool tackles and labour etc. complete for the work.
Providing and applying Polymatic cement primer on all surface applied @ 0.80 ltrs/10 sqm as per relevant IS code 15489:1974 (product such as Birla white primacoat/activcoat, Asian Trucare, Dulux interior cement primer, Opus Calista / I10) with all tool tackles and labour etc. complete for the work.
Providing and applying of Acrylic primer on all surface applied @ 0.80 litrs/10 sqm as per relevant I.S. code 15489:1974 ( Product such as Asian Spark/suprimo , J.K. Primer, Dulux Acrylic Primer) with all tools tackles and labour etc. complete for the work.
Providing and applying Luxury plastic emulsion paint with roller application minimum three coats applied @ 1.25 lit / 10Sqm up to final finish as per relevant Type -1 Class D , C , B & A (Glossy /Semi Glossy and Matt , Egg Shell or Satin finish ) of required shade (Product such as Asian Royale Shyne,Dulux Velvet Touch, Berger Silk Luxury Emulsion ,Nippon Impression Pearl , Opus Pure Elegance) inclusive of providing abro tape on edges and article and cleaning of door, windows, floor and surface as required with all tools tackles and labour etc, complete for the work. (with 4 Years Warranty )
Providing and applying exterior surface with PREMIUM HEAVY DUTY (Glossy or Matt Finish) Exterior Emulsion paint of required shade to give protective and water proof finish, minimum three coats applied @ 1.43 lit / 10 Sqm up to final finish as per relevant I.S. Code 15489:2013 Type-2 Class D, C, B & A (Glossy / Matt / Egg Shell finish) having high DFT and silicon additive for elastomeric property (Product such as Asian Ultima, Dulux Weathershield Maxx, Berger Weathercoat All Guard, Nerolac Excel Total, Nippon Durafresh Expert, Opus Tru Look) inclusive of providing abro tape on edges and article and cleaning of door, windows, floor and surface as required with all tools tackles and labour etc. complete for the work. (With 4 Year Warranty)
Providing and applying acrylic modified resin EXTERIOR TEXTURED with special quality silica quartz plaster as an intermediate coating on external surface giving protective layer and decorative finish on plastered surface in approved design and shade (product such as Asian Apex Series Duracast Dulux weathersheald sandtax creation) as per manufacturer's specifications inclusive of providing abro tape on edges and article and cleaning of door, windows, floor and surface as required with all tools tackles and labour etc.complete for the work. 14.70.1 2.0mm thickness (average) having design scratched with leveled & smooth surface.
Providing and applying satin/ matt finish Enamel paint mimimum 2 coats in all surface applying @ 0.75 lit/ 10 Sqm up to required finish as per relevent I.S. code 2932: 2013 of (Product such as Asian satin Enamel, Dulux Promise Premium Enamel, Nerolac Synthatic Enamel, Opus Prime enamel) inclusive of providing abro tape on edges and article and cleaning of door, windows, floor and surface as required with all tools tackle and labour etc. complete for the work.
Providing and applying priming coat on wood work applied @ 0.50 lit/Sqm as per relevant IS code 3536:1999 ( product such Asian trucare, Burger Wood Keeper, Dulux Duwel wood primer) with all tool tackles and labour etc for complete the work.
Providing and applying FRENCH SPRIT POLISH on new wood work after preparing the surface by rubbing down smooth with sand papers, covering the knots, if visible, applying a coat of wood filler, cleaning the surface, applying various (minimum 4 coats) of French spirit polish @0.35 lit/Sqm till the surface gives high gloss. inclusive of providing abro tape on edges and article and cleaning of adjucent surface with all tools, tackles and labour etc. complete for the work.
Providing and applying Polishing in high gloss/matt finish MELAMINE CLEAR POLISH on wood work in required color/wooden shade texture with following process in the sequence as detailed below:1.The surface to be polished is rubbed with sand paper 80/120 no. & then with sand paper of 160/180 nos.2.Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs.3.On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing,then surface is applied with special grade melamine fillers to fill all the small and big holes/grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs.4.On this, 1st coat of melamine polish is applied with spray gun using melamine clear polishand melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs.The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of Engineer-in-Charge. Final coat to be done in 2 layers without gap of time. inclusive of providing abro tape on edges and article and cleaning of adjucent surface with all tools, tackles and labour etc. complete for the work.
Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : 18.1.3 White Orissa pattern W.C. pan of size 580x440 mm
Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : 18.4.1 White pedestal type
Providing and fixing 15 mm nominal bore uplasticised PVC connection pipe with PTMT nuts and PVC bush of approved quality and colour: 18.10.2 45 CM length
Providing and fixing vitreous china wash basin with C.I. brackets, 32 mm C.P. brass waste of standard pattern, including painting of brackets, cutting and making good the walls wherever required : 18.17.5 White Oval or round size 550x400mm.
Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink without drain board as per IS 13983 with C.I. brackets and stainless steel plug 40 mm including painting of fittings and brackets, cutting and making good the walls wherever required : 18.22.2 560x410 mm bowl depth 215 mm.
Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. 18.25.1 32 mm dia
Providing and fixing PVC waste coupling in wash basin/ sink. 18.26.2 40 mm
Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : 18.30.1 5mm thick mirror
Providing and fixing on wall face or under floor UV stabilized Unplasticised Rigid PVC pipes (single socketed) having 3.2mm wall thickness conforming to IS : 13592 4kg/sqcm) including required couplers, ointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion etc complete. 18.76.1 75 mm dia pipe.
110 mm dia pipe.
150 mm dia pipe.
Providing and fixing on wall face UV stabilized Unplasticised - PVC moulded fittings/ accessories having 3.2mm wall hickness for Rigid PVC pipes conforming to IS : 13592 (heavy) jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. 18.77.1 Tee/ Tee with door/ Bend 45°/ Bend 90° 18.77.1.1 75 mm
Vent covel 18.77.3.2 110 mm
Access door cap 18.77.4.1 75 mm
Nahani trap 110x75mm
Providing and fixing UV stabilized Unplasticised -PVC pipe clips of approved design to Rigid PVC pipes by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 18.78.1 75 mm
Providing and fixing on wall surface G.I. pipes medium class complete with G.I. fittings and clamps, including cutting, making good the walls etc. and testing of joints complete Internal work -Exposed on Wall 19.7.1 15 mm nominal outer dia pipes
20 mm nominal outer dia pipes
25 mm nominal outer dia pipes
32 mm nominal outer dia pipes
40 mm nominal outer dia pipes
50 mm nominal outer dia pipes
Providing and fixing concealed in wall G.I. pipes medium class complete with G.I. fittings and clamps, including painting with anti corrosive bitumastic paint, cutting chases, making good the walls etc. and testing of joints complete: 19.8.1 15 mm dia nominal bore
20 mm dia nominal bore
25 mm dia nominal bore
Providing and fixing G.I. union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (new work) 19.11.1 15 mm nominal bore
20 mm nominal bore
25mm nominal bore
32mm nominal bore
40 mm nominal bore
50 mm nominal bore
Providing and fixing 15 mm nominal bore C.P. brass fittings of approved make and conforming to IS:8931 including C.P. brass extension if required: 19.14.1 Bib cock (400 grams)
Long nose bib cock (500 grams)
Piller Cock (400 grams)
Stop cock (concealed) (600 grams)
Angle valve for basin mixer and geyser points (450 grams)
Hand shower set with flexible extension pipe
Soap dish plate
Providing and fixing stainless steel drain jali of approved make/quality.
Providing and fixing of gun metal gate valve with CI wheel of approved quality (screwed ends) 19.16.1 25 mm nominal bore
32 mm nominal bore
40 mm nominal bore
50 mm nominal bore
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 19.17.1 15 mm nominal bore
20 mm nominal bore
25 mm nominal bore
Providing and fixing gun metal non- return valve (horizontal type) of approved quality (screwed end) : 19.18.2 32 mm nominal bore
40 mm nominal bore
50 mm nominal bore
Providing and fixing gun metal non- return valve (vertical type) of approved quality (screwed end) : 19.19.2 32 mm nominal bore
40 mm nominal bore
50 mm nominal bore
Painting G.I. pipes and fittings with synthetic enamel white paint over a red oxide zinc chromate priming coat, both of approved quality for new work: 19.21.1 15 mm diameter pipe.
20 mm diameter pipe.
25 mm diameter pipe
32 mm diameter pipe.
40 mm diameter pipe.
50 mm diameter pipe.
Painting GI pipes and fittings with two coats of anti corrosive bitumastic paint of approved quality 19.23.1 15 mm diameter pipe.
20 mm diameter pipe.
25 mm diameter pipe.
32 mm diameter pipe.
40 mm diameter pipe.
50 mm diameter pipe.
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
Providing, laying and jointing glazed stoneware pipes grade ‘A’ with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete : 20.1.1 100 mm diameter
150 mm diameter
200 mm diameter
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete 150mm thick as per standard design: 20.2.1 100 mm diameter S.W. pipe
150 mm diameter S.W. pipe
200 mm diameter S.W. pipe
Providing and fixing square-mouth S.W. gully trap grade 'A'’ complete with C.I. grating brick masonry chamber with well burnt modular clay bricks crushing strength not less than 35kg/cm2, water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design : 20.3.1 100x100 mm size P type
150 x 100 mm size P type.
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 20.5.1 100 mm dia. R.C.C. pipe
150 mm dia. R.C.C. pipe
Constructing brick masonry manhole with well burnt modular clay bricks crushing strength not less than 35kg/cm2 in cement mortar 1:4 ( 1 cement : 4 coarse sand), R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation in cement concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement complete as per standard design : 20.7.1 Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) :
Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (medium duty) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg (weight of cover 58 kg and weight of frame 58 kg) :
Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (heavy duty) 560 mm internal diameter, total weight of cover and frame to be not less than 208 kg (weight of cover 108 kg and weight of frame 100 kg) :
Inside size 90x80 cm and 45 cm deep including RCC cover with frame 450x600 mm internal dimensions.
Inside size 120x90 cm and 90 cm deep including RCC cover with frame 500 mm internal diameter.
Extra for depth for manholes 20.8.1 Size 90x80 cm
Size 120x90 cm
Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) as per standard design: 20.11.1 With 20x20 mm square bar
Supplying and fixing C.I. cover without frame for manholes : 20.14.1 455x610 mm rectangular C.I. cover (light duty) the weight of the cover to be not less than 23 kg.
providing and constructing brick masonry road gully chamber 50x45x60 cm with well burnt modular clay bricks crushing strength not less than 35kg/cm2 in cement mortar 1:4 1 cement: 4 coarse sand including 500x450 mm precast R.C.C. horizontal grating with frame complete as per standard desing.
Providing and constructing brick masonry road gully chamber 45x45x77.5 cm with well burnt modular clay bricks crushing strength not less than 35kg/cm2 in cement mortar 1:4 (1 cement : 4 coarse sand ) with precast R.C.C. vertical grating complete as per standard design.
Providing and constructing brick masonry chamber for underground pipe and and bends with well burnt modular clay bricks crushing strength not less than 35kg/cm2 in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) R.C.C. top slab with 1:2:4 mix (1 cement :2 coarse sand : 4 graded stone aggregate 20 mm nominal size) foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design : 20.28.3 Inside dimensions 600x 850 mm and 45 cm deep for pipe line with three or more inlets :
Providing and constructing soak pit 1.20x1.20x1.20m filled with brickbats including S.W. drain pipe 100 mm diameter and 1.20 m long complete as per standard design.
Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, upto 90 metre depth below ground level. 21.1.1 All types of soil 21.1.1.3 150 mm dia
Rocky strata including Boulders 21.1.2.3 150 mm dia
Boring/drilling bore well perfectly vertical for the specified depth suitable to receive required dia for casing/ strainer pipe, by suitable method Prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer–in-charge beyond 90 metre & upto 150 metre depth below ground level. 21.2.2 Rocky strata including Boulders 21.2.2.3 150 mm dia
Supplying, assembling, lowering and fixing in vertical position in bore well, ISI marked G.I. casing pipe (Plain) medium class in 4 to 7 meters length one end fitted with socket as per IS: 1239 (Part-1&Part-2) 1992 with IVth revision (Up-to-date amendments), of reputed & approved make, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of Engineer- in-charge. 21.5.3 150 mm nominal dia
Supplying, assembling, lowering and fixing in vertical position in bore well, slotted casing pipe made from ISI marked G.I. pipe (Plain) medium class in 4 to 7 meters length one end fitted with socket as per IS: 1239 (Part-1&Part-2) 1992 with IVth revision (having slot of size 1.6/3.2 mm), of reputed and approved make, including hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of Engineer-in-charge. 21.6.3 150 mm nominal dia
`Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge.
Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for bore well of: 21.11.3 150 mm dia
Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tube well as per IS: 2800 (part I), including necessary bolts & nuts of required size complete. 21.12.3 150 mm clamp.
Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tube well as per IS:2800 (part I). 21.13.3 150 mm dia
Supplying, filling, spreading & leveling stone boulders/ Gravels/ Coarse sand, in recharge pit, in the required layers and thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. (excavation of pit will be paid separately). 21.14.1 Stone boulders of size range 5 cm to 20 cm, in recharge pit
Gravels of size range 5 mm to 10 mm, over the existing layer of boulders
Coarse sand of size range 1.5 mm to 2 mm over existing layer of gravel
Supplying and stacking of good earth at site including royalty, loading, unloading and carriage upto 5 km(earth measured in stacks will be reduced by 20% for payment). Landscape area
Supplying and stacking at site well decayed cowdung manure fromapprovedsource, including loading, unloading and carriage upto 5km(manure measured in stacks will be reduced by 8% for payment). Park Area( site area )
Rough dressing the trenched ground including breaking clods. garden area
Uprooting weeds from the trenched area after 10 to 15 days of its floodingwithwater including disposal of uprooted vegetation.
Fine dressing the ground
Spreading of sludge, dump manure or/and good earth in required thickness (Cost of sludge, dumpmanure or/ and good earth to be paid separately).
Mixing earth and sludge or manure in proportion specified or directed.
Grassing with ‘Doob’ grass including watering and maintenanceof the lawnfor30 daysormoretill thegrassforms a thick lawn free fromweeds and fit for mowing including supplyinggoodearth if needed (the good earth shall be paid for separately). 22.10.2 In rows 5 cm apart in either (ground cover to be planted in kyari planters)
Preparation of beds for hedging and shrubbery by excavating 60cmdeep and trenching the excavated base to a further depth of 30cm, refilling the excavated earth after breaking clods and mixing with sludge or manure in the ratio of 8:1 (8 parts of stacked volume of earth after reduction by 20%: onepart of stacked volume of sludgeor manure after reduction by 8%), flooding with water, filling with earth if necessary,watering and finally fine dressing, leveling etc. including stacking and disposal of materials declared unserviceable and surplus earthby spreading and leveling as directed,with in a lead of 50m lift upto 1.5 m complete(cost of sludge, manure or extra earth to be paid for separately). total plantation kyari
Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume(2parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reductionby 8%) flooding with water, dressing including removal of rubbish and surplus 22.14.1 Holes 1.2 m dia and 1.2 m deep. peripheral and trees
Holes 60 cm dia, and 60 cm
Edging with modular well burnt clay bricks ofcrushing strength not less than 25kg/ sqcm laid dry length wise including excavation, refilling, consolidating with hand packing and spreading neatly surplus earth within a lead of 50 m :
Filling mixture of earth and sludge or manure in the desired proportion in trenches, flooding with water and leveling (cost of supplying earth and sludge or manure and mixing excluded).
providing and planting following herbs in garden including preparation of soil, base plantation , providing and supplying different fertilizers, soil and manure. 22.25.1 hedgeslike acalypha, tikoma,etc ( provision of shrub)
fern like Arica, china etc (provision of peripheral tree)
hibiscus/rose (provision of large shrub and ground cover)
carpet grass well developed
Supply, erection, jointing, testing & commissioning of "C" Class MS pipes (as per IS: 1239) including necessary specials such as tees, bends, flanges reducers etc., complete on wall/ ceiling. The pipes to be erected on wall or suspended from beams, RCC roof slabs with suitable size MS bars/ angle irons including painting of metal part except pipe line. 23.1.1 50mm dia.
65mm dia.
80mm dia.
100mm dia.
150mm dia.
Painting for M.S. pipe with a coat of red oxide primer and two or more coats of synthetic enamel paint of approved colour and Quality to give an even shade including surface preparation. 23.2.1 50mm dia.
65mm dia.
80mm dia.
100mm dia.
150mm dia.
Providing, installation, testing and commissioning of dual plate non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc. as required 23.4.1 80mm nominal bore
150mm nominal bore
Supplying, fixing, testing and commissioning of flanged butterfly valve PN 1.6, with Bronze/Gunmetal seat duly ISI marked complete with Nuts, Bolts, washers, gaskets, conforming to IS: 13095 of following sizes as required 23.5.1 80 mm dia
100 mm dia
150mm dia nominal bore.
Providing and fixing Flow switches suitable for fixing in 50mm to 150mm dia pipe line, complete with all accessories to provide indication in annunciator panel On 80/100mm dia line
Supplying and installing pressure gauge of 100 mm Ø., 0-300 PSI or 0-21 kg per cm square fitted with 12/15 mm Ø. pad cock valve, and G.I. pipe, elbow etc. as per requirement in approved manner
Providing and fixing 15 mm dia, Quartzoid bulb type G.M. Sprinkler Head set to operate at 680C of approved make chrome plated complete in all respect as required
Supplying and fixing double headed internal hydrant valve with instantaneous Gun metal couplings of 63 mm dia with cast iron wheel ISI marked conforming to IS: 5290 (Type - A) with blank Gunmetal cap and chain as required
Supplying and fixing 63 mm dia, 15 mtr long Flax canvas hose pipe with63 mm dia Male and Female Stainless Steel-IS: 3444 Grade-1 couplings duly binded with GI wire, rivets etc. conforming to IS: 636 (Type -A) as required.
Supplying & fixing 63 mm dia Stainless Steel IS: 3444 Grade-1 branchpipe with 20 mm dia (nominal internal) Gun Metal nozzle conforming to IS:903, suitable for instantaneous coupling connection to connect hose pipe coupling as required.
Supplying and fixing of MS hose cabinet box of made of 2 mm thick MS sheet and 40 x 40 x 5mm angle iron with front openable cover having 6 mm thick glazed glass viewing window i/c necessary locking arrangement, on existing wall/ brick platform etc complete as required 23.25.1 Size 1800 mm x 900 mm x 500 mm
Supplying and fixing 4 way Fire Brigade Connection of cast iron body with 4 Nos. Gun metal male instantaneous inlet couplings complete with cap and chain conforming to IS: 904 including connection to existing MS pipe line complete as required.Four Way
Supplying and fixing 2 way Fire Brigade Connection of cast iron body with 2 Nos. Gun metal male instantaneous inlet couplings complete with cap and chain conforming to IS: 904 including connection to existing MS pipe line complete as required. Two Way
Providing and fixing standard fireman's axe (tested for 20000 Volts) with heavy insulated rubber handle. (ISI marked)
Supplying and installing Air Vessel of 300 mm dia, 1.5m in height made of 5mm thick MS sheet including painting with one primer and two finish coats complete as per specification
Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned up to a lead of 1000 meters including removal and disposal of top organic soil not exceeding 150 mm in thickness if required and as per relevant clauses of section-200. (A) In area of light jungle
Excavation in Soil (by Mechanical Means.) Excavation for roadway in soil using mechanical means including loading in tipper for carrying of cut earth to embankment site and unloading with all lifts and lead upto 1000 meters as per relevant clauses of section 300.
Surface Drains in Soil (Construction of unlined surface drains of average cross sectional area 0.40 sqm in soil to specified lines, grades, levels and dimensions to the requirement of clause 301 and 309. Excavated material to be used in embankment within a lead of 50 meters (average lead 25 meters))
Providing and laying Pre cast RCC slab over RCC drain of required size made of grade RCC M-25 with 50mm dia perforation @ 600mm c/c in two rows in zig-zag pattern as per structural drawing including transportation of pre cast segements to work site and placing over drain as instructed by Engineer-in-charge. (i) Slab with reinforcement 10mm dia at 150mm c/c both ways A. 690 mm wide and 120mm thick (for drain 450 x 450 mm)
840mm wide and 150mm thick (for drain 600 x 600 mm)
Providing and laying Pre cast RCC open drain of required size made of grade RCC M-25 as per structural drawing including arrangements for lifting, placing and jointing in drain segments, transportation of pre cast segements to work site excavation, 100mm thick base concrete grade M-15 laid in required slope, placing the drain segements in required slope, aligning to line and length, including joining of the drain segements to each other with cement mortar 1:1 and back filling of haunches including compacting to required density as instructed by Engineer-in-charge as per drawing. Drain with wall thickness 120mm thick and reinforced with A. 8mm dia U bars at 150mm c/c and 8mm dia longitudinal bars at 150mm c/c (i)450 mm x 450mm opening
600 mm x 600mm opening
Granular Sub-base as per Table:- 400-1 Construction of granular sub-base by providing graded material, carriage of mixed material to work site spreading in uniform layers with motor grader on prepared surface watering rolling and compacting with vibratory power roller at OMC to achieve the desired density, complete as per clause (A) Plant mix method with Mechanically crushed stone only) (a) for sub-base cum drainage layer or upper sub-base with (i) grading-III Material
Construction of granular sub-base by providing graded granular material mechanicaly mixed in plant confirming to required grading mentioned in Appendix-VI and Clause 5.7.3.9 of IRC:58-2015, carriage of mixed material to work site, spreading in spreading in uniform layers with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per clause 401. By Plant mix method (with mechanically crushed stone only) (A) For Sub-Base as per AASTHTO 93 : Grading 6 of Table VI-I
Wet mix makadam (providing, laying, spreading and compacting graded stone aggregate to wet mix makadam specification including premixing the material with water at OMC in mechanical mix plant carriage of mixed material by tripper to site, laying in uniform layers with paver in Sub-base/ course on well prepared surface and compacting with vibratory roller to achieve the desired density as per clause 406.)
Providing & laying precast interlocking concrete blocks of required compressive strength with approved size , shape/ pattern over coarse sand bed of thickness 30+/- mm and joints thick filled with fine sand including leveling with surface vibrator, temping and sweeping etc. complete as per IRC-SP-63-2004. (B)80mm thick precast interlocking concrete block of C.C. M-40 grade on area of Light traffic/residential streets (ii) 80mm thick polymer coated coloured precast interlock concrete blocks
Prime coat (providing and applying primer coat with oil based bitumen emulsion SS-1, grade confirming to IS: 8887) on prepared surface of granular base including clearing of road surface and spraying primer using mechanical mains as per clause 502 5.1.1 on WBM/WMM surface @0.85 kg/sqm.
Tack coat Providing and applying tack coat with bitumen emulsion RS-1, grade confirming to IS:8887)using emulsion pressure distributor on the prepared bituminous/granular surface cleaned with mechanical broom and as per clause 503. 5.2.1 Granular surface treated with primes @ 0.3 KG/sqm
Dence bituminous macadam (providing and laying dence bituminous macadam with minimum 40-60 TPH capacity HMP using crushed aggregates of specified grading, premixed with bituminous binder @ 4.0 to 4.5% by weight of total mix of mix and filler transporting the hot mix to work site, laying with a hydrostatic paver finisher to the required grade level and alignment rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per MORTH specification clause No.505 complete in all respects.) (A) with sensor paver finisher 5.4.1 for Grading-II (26.5 mm nominal size,aggregate bitumen content 4.5%)
Bituminous concrete providing and laying bituminous concrete with minimum 40-60 TPH capacity hot mix plant using crushed aggregates of specified grading, premixed with bituminous [email protected] to 6.0% by weight of total mix of mix and filler, transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the required grade, level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per MORTH specification clause No. 507 complete in all respects) (A) with sensor paver finisher 5.7.1 for Grading-II (13.2 mm nominal size aggregate) with bitumen 6%
Providing and laying cement concrete for plain concrete/ reinforced concrete i/c form work, shuttering complete in as per drawings and specifications.( For Village roads) (i) P.C.C. M-10
Providing and laying Un-reinforced Cement Concrete without Dowel bars including formwork and expansion, contracion & longitudinal joints as per design and as per IRC-62 over a prepared base a pre approved mix design and finishin to lines and grade as per Drawing for and finising to lines and grade as per Drawing for Pavement thickness less than 200 mm in Low volume roaes. with cement concrete M-30 and minimum cement content @ 375 kg/cum
Providing and laying Reinforced Cement Concrete pipe NP 3 / prestressed concrete pipe on first class bedding. (Laying Reinforced cement concrete pipe NP3 /prestressed concrete pipe for culverts on first class bedding of granular material including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets . ) 600 mm dia
Providing and laying of a reinforced cement concrete pipe duct, 300 mm dia, complying to IS:458, across the road ( new onstruction ) , extending from drain to drain in cuts and toe of slopes to toe of slopes in fills, excluding constructing head walls at both ends, providing a minimum fill of granular material over top and sides of RCC pipes, bedded on a 0.3 m thick layer of granular material free of rock pieces , outer to outer distance of pipes at least half dia of pipe subject to minimum 450 mm in case of double and triple row ducts , joints to be made leak proof, invert level of duct to be above higher than ground level to prevent entry of water and dirt, all as per IRC:98 and approved drawings. (A) NP-3 Pipe (i) Single row for one utility service 300mm dia 600 mm dia
Providing and laying at the site 8mm thick PERGO, Kahrs, Inter tex, laminated wooden floor or approved equivalent (Class of use 23 (31), AC-5 as per en 13329) with top of specially development substract core of plank size 1288mm x 196mm having SMART look tongue and groove construction with edges duly impregnated to secure long lasting joints secured together conforms to EN 13329. The underlay has to be a 1.8mm thick ALKALI RESISTENT POLYTHYLENE sheet (PERGO Polythylene foam or approved equivalent with a 2mm thick extruded polythylene foam of PERGO or approved equivalent on top to secure the floating for installation. All including all complete as directed by the Engineer-in- charge.
Providing and fixing Acoustical Sandwiched Doors of size from First class teakwood frame of finished size 225mm x 80 mm and 66mm thick finished shutters consisting of 100x42mm teakwood style, top and lock rail 125x42 and bottom rail, 150x42mm, and intermediate 25mmx42mm Teak wood horizontal members,with 8mm thick BWP 710 grade ply on both sides and 4mm thick natural veneer (BWP grade) with grooves on one side (Green ply Century make or equivalent). 50mm thick core of Glass wool slab (24 kg density)16g Fiber glass tissue paper sandwitched inside and 25mm thick 32 density kurlon make foam with 1 mm thick leatherite, stitched in rombus shape on inside. Heavy duty stainless steel hinges (152mmx76mmx3mm) 316 grade with bearings with Pin and cap, 300mm tower bolts ss 304 grade, 450mm heavy handle ss 316 grade, 350mm heavy duty Aldrops ss 316 grade, heavy door stoppers (zinc), rubber buffers, concealed hydraulic door closer aluminum extruded wt. up to 90 kgs, (Ozone or Yale make) as per drawing schedule of fitting and fixtures of (kich, Godrej make or equivalent). All around edge Teak wood bead 70mm x 12mm thick, including finishing the over all surface with thinner polish spray and P.U. coating etc, complete to the satisfaction of Engineer in Charge.
For terraces over pre layed PUF insulation : 195.1 Providing and laying roof insulation with 60 mm thick impervious sprayed, closed cell free Rigid Polyurethane foam over deck insulation conforming to IS - 12432 Pt. III (density of foam being 40-45 kg/ cum), over a coat of polyurethane primer applied @ 6-8 sqm per litre, Waterproofing shall be spray applied directly above PUF insulation (as per specifications, Payable extra) protection of waterproofing shall be done using 400 G polythene sheet and providing a wearing course with average 75 mm thick cement screed 1: 2 : 4 (1 cement : 2 coarse sand : 4 stone aggregate 20 mm nominal size) in chequered rough finish, in panels of 2.5 m x 2.5 m and embedding with 24 G wire netting and sealing the joints with polymerized mastic, all complete as per direction of Engineer-in-Charge.
Providing and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm x 10 mm) with SRI (solar refractive index) > 78, solar reflection > 0.70 and initial emittance > 0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge.
For exposed area of walls(U.V. STABLE TOP COAT) Protection of exposed waterproofing membrance with 2K-PU top coat , high solids, pigmented, UV stable for roofing systems and smooth surfaces. Providing and applying of Masterseal TC269 which is a pigmented , low viscosity , two component polyurethane topcoat. It cures to a elastic tough , hard wearing , glossing finish used over as top coat on Masterseal M800 water proofing system, coverage appx0.15-.20 kg/sqm. ( characterics : Elongation at break ( after 14 days) DIN53504 - 165 : Tensile strength (after 14 days) DIN53504 - 12 : Tear resistance (after 14days) DIN 53515 - 70 manufactured by BASF India Ltd or equivelent product from Fosroc chemicals India Pvt.Ltd MYK Schomborg or Ardex endura India Pvt.Ltd )
Providing and fixing ISI marked 50mm flush door shutters conforming to IS :2202 (Part I) decorative type, core of block board construction with frameof 1st class hard wood and well matched teak 3 ply veneering with verticalgrains or cross bands and face veneers on both faces of shutters.
Supplying and fixing dray cladding system with HPL from M/S Fundermax , Stylam Industries Ltd.(Fascia )or with Century Exterior HPL Exteria -high- quality exterior grade decorative cladding for balconies and building facades with non corresive rivets. The material should confirm to EN 438-6 type EDF (resistance against extreme climatic conditions and UV) and rates of fixing ,includes base frame which consist of aluminium frame size 25mmX50mm , fixed in grid size 600mm c/c with necessary powder coated bolts, caps etc, complete.
Supplying and fixing in position at the location as shown in the drawings or as directed by Engineer Incharge following type of satin finish stainless steel signages 316 Grade with counter sunk S.S.316 grade Screws complete. 209.1 S.S.316 Grade Sign Plate of 120 X 120 X 1.5 mm - for direction and Disabled signages etc.
S.S.316 Grade Sign Plate of 120 X 120 X 1.5 mm - for male&/female ,Fire,Pull ,Fire Exit signages etc.
Providing and fixing Glass Reinforced Concrete (G.R.C) screens in approved size, pattern, design, thickness and approved color from f M/S UniStone or equivalent approved. The screens should be made from ‘53 grade’ Cement manufactured by ‘JK Cement’ or equivalent, Fine graded Quartz & Silica Sand, Alkali Resistant Glass Fiber manufactured by ‘N.E.G. JAPAN’ or equivalent, Super Plasticizers manufactured by ‘BASF’ or equivalent, Polymers manufactured by ‘BASF’ or equivalent and U.V resistant Synthetic inorganic pigments should be used for pigmentation manufactured by ‘BAYFERROX (Germany)’ or equivalent. The material casting should take place in FRP Mould or equivalent. The fixing of Screens should be done with ‘Dry fixing’ methodology i.e. to be done with M.S. Galvanized ‘L’ shaped Clamps, dash fasteners and pins, as per approved shop drawings from Engineers in charge.Rates are inclusive of all the operations described above for all heights and leads including all scaffolding ,staging ,T&P and sundries eic.
Supplying and fixing Stainless Steel AISI 316 grade satin finished door hinge with 4 bearings ,of size 127x76x3 and SS self tapping philips cross head screws ,equivelent to Kich DH 235S
Providing and fixing of vendor- 65/400 OR 50/429Self Supported Secret Fix Aluminum STANDING SEAM ROOFING SYSTEM in 0.9 mm thick in AA-5052 Aluminium Alloy comprising of the following layers : 1.Top Layer - The topmost profiled sheeting of Aluminium Kingspan 65/400 self supported standing seam roof system manufactured from aluminium alloy AlMnlMg1 Quality AA 5052, in accordance with B209M/ BS-EN-485-2:1995 minimum material thickness of 0.90 mm and 60 Micron Durabond finish /60 Micron PVDF finish in accordance with BS-EN-1396: 2007 finish including Accessories. Original make of aluminum coil to be Gramco,Bahraun/Euramax,E.U/Hulemin,South Africa, and material test certificate (MTC) to be submited. The support halters shall be manufactured from extruded aluminium alloy 6082 T6 in accordance with BSEN 755 part 2. Each aluminium halter shall be coupled with a 6mm thick black polyamide thermal barrier base pad. The material properties shall be as follows: Ultimate tensile strength: minimum 200 N/mm2, 0.2% Proof Stress: min 185 N/mm2, Modulus of elasticity: 70,000 N/mm2. Sheets are to be laid in Single Length to meet the requirements of the building geometry and fixed on Aluminum Clip/ Halter and which is fixed to purlin through Bottom sheet with screws. (Color as per architect choice) Aproved Make: KINGSPAN / BEMO / SANKYO / VIJAYNATH Please note: Detail structural load calclation report to be submitted by the manufacturer based on wind load as per IS 875 and screw pull out force.
Supply and Fixing of 0.90 mm thick Aluminium Flashing (Specification same as above) maximum girth of 578 mm.
Providing and Fixing, testing and commissioning of vitreous china white over counter wash basin of Jaquar Cat No. DRS-WHT-37601 with 32 mm dia C.P. brass bottle trap Jaquar Cat No. ALD769L300X190 with CP brass waste Jaquar Cat No. ALD727, wall flanges and rubber adapters for waste connection complete including CI/MS brackets duly painted, nuts, washers, cutting and making good the walls floors wherever required. The above product catalogue nos are to be considered as a Set as per make mentioned or Equivalent.
Providing and Fixing, testing and commissioning of hand spray (Health faucet) of Jaquar Cat No. ALD573 with flexiable hose connection, regulator with flexible pipe 1.2 m long, wall hooked complete as required, with Two way Bib Cock Jaquar Cat No. VGP-CHR-81041. The above product catalogue nos are to be considered as a Set as per make mentioned or Equivalent.
Providing and fixing 15mm dia. C.P. brass Short body bib cock of Jaquar Cat No. VGP 81037 or Equivalent including cutting and making good the walls wherever required complete as per directions of Engineer incharge.
Providing and fixing C.P brass toilet paper holder of Jaquar Cat No. ACN1153N or Equivalent including cutting and making good the walls wherever required complete as per directions of Engineer incharge.
Providing and fixing of towel ring of Jaquar Cat No. ACN1121BN or Equivalent complete in all respects including cutting and making good the walls required. Only attached Toilets.
Providing and fixing, jointing and testing of 15mm dia C.P. brass angle valve of Jaquar Cat No. VGP 81053 or Equivalent with C.P. brass wall flange with any other items complete including cutting and making good the walls wherever required as per direction of Engineer-Incharge.
Providing and fixing steel grab bar of Jaquar Cat No. AHS1507 or Equivalent.
Providing and Fixing, testing and commissioning of CP Braided hoses connection of Jaquar Cat No. ALD805B or Equivalent of 450 mm long including nuts and washers and making connection to fixtures and fittings complete as required.
Providing and fixing white vitreous china URS-WHT-13261 having water inlet from, top with Presmatic PRS-CHR-077 , Bottle trap- ALD-CHR- 769L300X190 , Waste Coupling ALD-CHR 705. including fixing to wall with suitable brackets all as per manufacturers specification and direction of brackets all as per manufacturers specification and direction of engineer-in - charge. . The above product catalogue nos are to be considered as a Set as per make mentioned or Equivalent.
Providing and fixing vitreous china flat back urinal basin Jaquar Cat No. URS-WHT-13253O with C.I. Hangers, C.P. spreader with short bent, electronic flushing system comprising of electronic & electrical items including infrared photo cells eyes, electronically operated solenoid valve, step down equipment, electric operated, concealed copper piping etc.with P- trap siphon and concealed urinal sensor of Jaquar Cat No. SNR-STL-51087 & connection kit for urinal and any other item required to provide satisfactory functioning, waste and jali to prevent napthelene balls from going inside the pipe and connecting pipe to wall with C.P. flange complete including cutting and making good the walls and floors where required. . The above product catalogue nos are to be considered as a Set as per make mentioned or Equivalent.
Providing and Fixing, testing and commissioning of ABS+PMMA Built in Bath tub, of Jaquar Cat No. Fusion JBT-WHT-KUBIX180X, 1800 x 800 x 470 with head rest- JWA-BLK-HRCP750GAC06 and Front panel JWA- WHT-KUBIXFPX, side panel JWA-WHT-KUBIXSPX, and bath tub filler ,with hand Shower divertor and filler - JWA-CHR-ACC00820X including complete set, drain connection pipe with overflow- JWA-CHR- DRNPIPE70, on Atlas frame IWA-CHR-ACC0051SSX, along with wall flanges and rubber adapters for waste connection complete including CI/MS brackets duly painted, nuts, washers, cutting and making good the walls floors wherever required. . . The above product catalogue nos are to be considered as a Set as per make mentioned or Equivalent.
Providing and fixing S.S finish Countertop Manually operated liquid soap dispenser with glass bottle Jaquar Cat No. CAN-CHR-1135 or Equivalent.
Providing and fixing fully automatic hand drier of / Jaquar Cat No. HDR- SAP-M99ACS or Equivalent complete to the satisfaction of Engineer in charge suitable to operate on 220 volts, single phase 50 hz, A.C. power supply.
Providing and fixing CP brass Sink Mixer Cock- Wall Mounted (Jaquar Cat. No. VGP-CHR-81165 or Equivalent , including cutting and making good the walls wherever required.
Providing and Fixing, testing and commissioning of shower Panel of Jaquar Cat No. JPL-WHT-G0843JAX or Equivalent including wall flanges and rubber adapters for waste connection complete including CI/MS brackets duly painted, nuts, washers, cutting and making good the walls floors wherever required.
Providing and Fixing, testing and commissioning of shower Panel of Jaquar Cat No. GPL-SSF-ST88158B or Equivalent including wall flanges and rubber adapters for waste connection complete including CI/MS brackets duly painted, nuts, washers, cutting and making good the walls floors wherever required.
Providing and Fixing, testing and commissioning of Steam module of Jaquar Cat No. ASG-WHT-PIUVAP1117 - 6 KW or Equivalent including wall flanges and rubber adapters for waste connection complete including CI/MS brackets duly painted, nuts, washers, cutting and making good the walls floors wherever required.
Providing and Fixing, testing and commissioning of Steam Cabin of Jaquar Cat No. ASG-WHT-BOXJAQ1201 or Equivalent including All showers, vertical body SPA, steam, thermostat, chromo therapy lights, Aroma Therapy, Control Touch Panel with Entertaintment system and necessary wall flanges and rubber adapters for waste connection complete including CI/MS brackets duly painted, nuts, washers, cutting and making good the walls floors wherever required.
Providing and Fixing, testing and commissioning of Towel Rack of Jaquar Cat No. AHS-CHR-581H or Equivalent with flexiable hose connection, regulator with flexible pipe 1.5 m long, wall hooked complete as required.
Providing and Fixing, testing and commissioning of Jaquar Cloth Liner AHS- CHR-1565 or Equivalent with flexiable hose connection, regulator with flexible pipe 1.5 m long, wall hooked complete as required.
Providing and Fixing, testing and commissioning of Magnifying Mirror of Jaquar Cat No. ACN-1193N or Equivalent with flexiable hose connection, regulator with flexible pipe 1.5 m long, wall hooked complete as required.
Providing and Fixing, testing and commissioning of Sauna- 4 Persons of Jaquar Cat No. ASU-NAW-1102A220 or Equivalent including inside outside control panel, thermal heater, stove heater, hygo meter, thermometer, laddle and bowl, lumber support, chromotherapy light, ambient light, entertaintment system, glass enclosure, Cedar wood inside and outside and also wall flanges and rubber adapters for waste connection complete including CI/MS brackets duly painted, nuts, washers, cutting and making good the walls floors wherever required.
Providing and Fixing, testing and commissioning of Hot Water Solutions with M.S. 425 liter centralised Geyser- VRN-DUN-425 Verna or Equivalent high capacity 425 litre, with Powder coated body, and Blue lined diamond coating including CI/MS brackets duly painted, nuts, washers, cutting and making good the walls floors wherever req.
Solar Water Heating System of 500 Liters/ Hr Capacity with Combined Heat Pump Technology or 2000 LPD Conventional Package solar water heating system based on a closed circuit indirect heat transfer system and capable of producing specified quantity of water at 60 deg C during peak winters. The system shall essentially consist of insulated storage tank, collector panels, insulated interconnecting pipe work, electric booster, supporting structure, electrical back up all complete.
Providing and fixing M.S. puddle flanges fabricated of 750 mm long pipe pieces to RCC water tank wall/slab. The entire fitting shall be hot dipped galvanised (Flanges shall confirm to BS10 Table E). 32 mm dia (Screwed ends MS plate 6 mm thick; 100 mm x 100 mm plus dia of pipe).
50 mm dia (Screwed ends MS plate 6 mm thick; 100 mm x 100 mm plus dia of pipe).
80 mm dia (Screwed ends MS plate 6 mm thick; 100 mm x 100 mm plus dia of pipe).
100 mm dia (Screwed ends MS plate 6 mm thick; 250 mm x 250 mm plus dia of pipe).
Supply, installation, testing & commissioning of 150 mm dia flanged type water flow alarm check valve with ductile iron body, bronze seat ring and cast iron/ductile iron clapper, suitable for operation in working pressure range of 1.4 bars to 20 bars complete with pressure gauges with brass isolation valves, by-pass check valve, main drain valve, alarm test valve, turbine principled alarm gong, stainer and test terminal box as per technical specifications and all requirements of contract works.
Providing and fixing inspectors 25 mm dia test assembly complete with test valve, sight glass sectional drain valve, union; necessary piping, threading, jointing & with corrosion resistant orifice all complete as per techincal specification and all requirement of contract works.
DIESEL ENGINE PUMP Supplying, Installation, Testing and Commissioning of Diesel engine driven main fire pump suitable for automatic operation and consisting of following: complete in all respect as required. Horizontal type, multi stage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seat to ensure a minimum pressure of 3.5 kg/sq.cm at highest and farthest outlet at specified flow of 2280 lpm at 60 m. head conform.Suitable for 50 BHP, 1500 RPM water cooled with radiator, diesel engine confirming to relevant BS & IS standard complete with auto starting mechanism, 12 volts/24 volts electric starting equipment, Diesel Tank, Exhaust pipe extended upto 1 m. outside pump house. M.S. fabricated Common base plate, coupling , coupling guard, foundation bolts etc. as required. Suitable cement concrete foundation duly plastered with anti vibration pads.
ELECTRICAL PUMP Supplying, Installation, Testing and Commissioning of Electric driven main fire pump suitable for automatic operation and consisting of following: complete in all respect as required. Horizontal type, multi stage, centrifugal, split casing pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal to ensure a minimum pressure of 3.5 kg/sq.cm. at highest and farthest outlet at specified flow of 2280 lpm at 75 m. head .60 HP Squrrel cage induction moto, TEFC, synchronous speed, 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz. AC with IP 55 protection for enclosure, horizontal foot mounted type with Class-"F" insulation, conforming to IS:325. M.S. fabricated Common base plate, coupling , coupling guard, foundation bolts etc. as required. Suitable cement concrete foundation duly plastered with anti vibration pads.
JOCKEY PUMP Supplying, Installation, Testing and Commissioning of Electric driven pressurisation pump suitable for automatic operation and consisting of following: complete in all respect as required. Horizontal type, single stage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal and flow of 180 lpm at 75 m. head conforming to IS:1520 Suitable 10HP Squrrel cage induction moto, TEFC type suitable for operation on 415 volts, 3 phase 50 Hz. AC with IP 55 class of protection for enclosure, horizontal foot mounted type with Class-"F" insulation, conforming to IS:325. M.S. fabricated Common base plate, coupling , coupling guard, foundation bolts etc. as required. Suitable cement concrete foundation duly plastered with anti vibration pads.
Fabricating, supplying, Installation, testing and commissioning of electrical control panel of cubicle construction, floor mounted type, fabricated out of 2 mm thick CRCA sheet. Compartmentalised with hinged lockable doors, dust and vermin proof cable alley, inter connection, having switchgears and accessories mounting and internal wiring, earth terminal, numbering etc.complete in all respects, suitable for operation on 415 V. 3 phase, 50 Hz AC supply with enclosure protection class IP 42 as required.
Providing & Fixing Fiberglass Top- Mount Filter " FILTER PLANT specially designed for water pond application molded out of U V Stabilized Re-enforced Fiber glass ISO Resin and chopped strand Fiber mat & Woven Robbin mat with 12mm wall thickness with Gel coat based pigmented colour tested for 6Kg/cm2 for pressure and with working pressure of 3kg/cm2, complete with 5 Function Single lever Operated Multiport Valve, First Charge Multi graded Quartz Filter Media with in built, Filtration, Backwash,rinse and drain systems.This Filter does not require any painting to protect it from corrosive nature of the site .Average flow rate of the filter will be 70000 liters per hour.(X 8 hours TOP) Size of the Filter will be 1100mm dia X 2 Set make Emaux "Aqua pac" Series or equivalent
Providing & Suppling PVC Rigid Pipe 160mm Outside Diameter Class-3 6Kgf/cm2 Wall Thickness 3.7mm-4.3mm as per IS : 4985:2000
Providing & Suppling PVC Rigid Pipe 110mm Outside Diameter Class-3 10Kg/cm2 Wall Thickness 2.5mm-3.0mm IS : 4985:2000
Providing & Suppling PVC Rigid Pipe 63mm Outside Diameter Class-2 10Kg/cm2 Wall Thickness 1.5mm-1.9mm IS : 4985:2000
Providing & Fixing A.B.S. Make Drainage Outlet SP -1031 (230mmx230mm) on floor Water tank interconnected with drainage outlet pipe.Floor:112 GPM,Wall : 83 GPM, 151.4 [email protected]. RTROFIT COVER with 4 Grates includes inner frame,cover & screws
Providing & Fixing Heavy duty Tee 110mmx63mm & Pressure rating 10Kgf/cm2 as per IS : 7834-1975
Providing & Fixing Heavy duty Tee 63mm & Pressure rating 4 Kgf/cm2 as per IS :7834-1975
Providing & Fixing Heavy duty Cap 63mm & Pressure rating 4 -6 Kgf/cm2 as per IS : 7834-1975
Providing & Fixing Heavy duty Elbow 160mm & Pressure rating 6 Kgf/cm2 as per IS : 7834-1975
Providing & Fixing Heavy duty Elbow 110mm & Pressure rating 6 Kgf/cm2 as per IS : 7834-1975
Providing & Fixing Heavy duty Elbow 63mm & Pressure rating 4 Kgf/cm2 as per IS : 7834-1975
Supply & Installation with allied fittings of PVC 110mm dia pipe. Anti corrosive PVC pipe with resistant of working pressure not less than 10kg/sqcm Following IS 4985-2000. Make Like Supreme/Finolex/Prince/Zolto/L&T
Supply & Installation with allied fittings of PVC 90mm dia pipe. Anti corrosive PVC pipe with resistant of working pressure not less than 10kg/sqcm Following IS 4985-2000 Make Like Supreme/Finolex/Prince/Zolto/L&T
Supply & Installation with allied fittings of PVC 50mm dia pipe. Anti corrosive PVC pipe with resistant of working pressure not less than 10kg/sqcm Following IS 4985-2000 Make Like Supreme/Finolex/Prince/Zolto/L&T
Supply & Installation with allied fittings of 110mm dia NRV. Horizontal/Vertical NRV for floor drain in side drain chamber at floor of swimming pool at deep end. Anti corrosive PVC NRV, As per ASTM-D1784. Make Like Supreme/Finolex/Prince/Zolto/L&T
Supply & Fixing with allied fittings of 110mm dia PVC pipe. Anti corrosive PVC butter fly valves in filtration room. As per ASTM-D1784 Make Like Supreme/Finolex/Prince/Zolto/L&T
Supply & Fixing with allied fittings of 90mm dia PVC pipe. Anti corrosive PVC butter fly valves in filtration room. As per ASTM-D1784
Supply & Fixing with allied fittings of 110mm dia PVC Foot valves in Balancing Tank. As per ASTM-D1784 Make Like Supreme/Finolex/Prince/Zolto/L&T
Providing and fixing of Floor Intel in pool tank made with ABS material in which colour which has unique design permits 360˚ dispersion of fresh water in the pool, incl. flange, gaskets & S/S-screws. Internal Ǿ 50mm & 50mm slip. The suction head should have capacity of water flow 12.0 m3/h. it should be totally resistant against pool chemicals.
Providing and fixing 4 steps Pool Ladder as per standard design on tank wall made with S.S.-304 grade pipe of 43mm dia, width 500mm. steps distance 250mm to be fixed with maintaining distance of 180mm from pool wall and to be fixed with required self expanding fastener etc. complete.
Providing and fixing Polypropylene grating at Dack level above over flow drain channel made with 35 x 295mm Polypropylene pieces will be jointed with push & fix arrangement. (approx. 45 pieces per meter)
Providing and fixing Semi transparent polyethelene tank with external scale for checking tank capacity of 500 Ltrs
Providing Moveable Suction swipping Trolley with 4 wheels of 6” dia.
P/F Suction Drain accessories with SS grill size 500mm x 500mm for water flow @ 100 m3/hr at required place of pool tank.
Providing Aluminium Vacuum head for Heavy duty use; 19” wide; 38/50mm connection weight: 4 kg Double Head 2 Fairlocks + connecting yoke.
Providing FLEXIBLE VACUUM HOSE dia 40mm and 30 M in Length Manufactured of UV resistant and long lasting plastics. (Supply should be packing in tearproof PE bags)
Providing TELESCOPIC ALUMINIUM POLE 3.5 to 7.5 M Extension with functional excenter length adjustment, ergonomic soft hand grip. (Patented system for easy and quick assembly of the cleansing accessories)
Providing ALGAE BRUSH SS BRITLES With stainless steel bristles SS-316 grade specially recommended for tile pools.
Providing CURVE BRUSH POLY BRISTLES With robust PPGF and UV resistant body.
Providing DEEP NET with reinforced and UV resistant PPGF frame and extra strong and finely woven extra deep net, with integrated dirt collection flaps and flat frame.
Providing TEST KIT TABLET TYPE including 20 x PH/CL test tablets each, transparent tester with legible and reliable colour scale.
Providing and Filling Silica 0.5mm to 0.8mm made out of crushed marble. Should be as per consultant & client engineer incharge approval.
Providing and Fixing cushion synthetic 9 layer (ACRYLIC U.V. Resuting ) surface consisting of one layer of resurface two layer of cushion and layer of colour and count marking .The job to be carried out as per internation standard of tennis court.( The colour synthetic coarting to be got approved before laying)
Wiring for light/ fan/ exhaust fan / call bell point with 3x1.5 sqmm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) with 5/6 amp modular switch, modular base and cover plate, suitable size G.I. box as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) 1.7.1 Short Point
Medium Point
Long Point
Wiring for twin control light point with 3x1.5 sqmm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) with 5/6 amp modular switch, modular base and cover plate, suitable size G.I. box as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5)
Extra for providing and fixing light plug point on board in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) point wiring with modular type 3 pin 5/6 amp socket outlet and 5/6 amp switch including cost of base and cover plate and G. I. box etc. as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5)
Wiring for light plug point with 3x2.5 sq mm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) along with modular type 6 Amp switch and 3 pin 6 amps socket outlet with modular base and cover plate, suitable size G.I. box, earthing the switch box and socket outlet with same size wire etc. as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) 1.10.2 Medium Point
Long Point
Extra Long Point I
Extra Long Point II
Extra Long Point III
Wiring for power plug point with 3x4 sq mm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) along with modular type 16 Amp switch and 6 pin 16 amps socket outlet with modular base and cover plate, suitable size G.I. box, earthing the switch box and socket outlet with same size wire etc. as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) 1.11.1 Short Point
Medium Point
Long Point
Extra Long Point I
Extra Long Point II
Extra Long Point III
Wiring for power plug point with 3x6 sq mm FRLS PVC insulated stranded copper conductor wire for phase, neutral and earth in concealed FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) along with modular type 32 Amp SPMCB "C" curve and 6 pin 20 amps socket outlet with modular base and cover plate, suitable size G.I. box, earthing the switch box and socket outlet with same size wire etc. as per specification and IS: 694 (2010), IS: 9537 (2000 Part 5) 1.12.3 Long Point
Extra Long Point I
Extra Long Point II
Extra Long Point III
Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in concealed PVC conduit as required. 1.13. 13 X 1.5 sq. mm in 20mm conduit
3 X 2.5 sq. mm in 20mm conduit
6 X 2.5 sq. mm in 25mm conduit
9 X 2.5 sq. mm in 32mm conduit
12 X 2.5 sq. mm in 32mm conduit
3 X 4 sq. mm in 25mm conduit
6 X 6 sq. mm in 32mm conduit
6 X 10 sq. mm in 40mm conduit
Supplying and fixing of following sizes PVC conduit along with accessories in concealed complete as required. 1.15.2 dia 25 mm.
dia 50mm.
Supplying and fixing of following sizes FRLS PVC conduit (heavy duty, thickness of pipe should be 2 mm) along with accessories in surface complete as per specification and IS: 9537 (2000 Part 5) 2.15.1 20 mm
Supplying and fixing of following sizes PVC casing caping along with accessories in surface complete as per specification and IS: 9537 (2000 Part 5). 2.16.1 20x12 mm
Supplying and drawing following grade co-axial TV wire FR PVC insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ concealed Steel/FRLS PVC conduit as per specification 3.13.2 RG-11 grade
Supplying and drawing UTP 4 pair Cat 6 LAN wire in existing surface/ concealed Steel/FRLS PVC conduit as per specification
Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as per specification. 4.4.1 75mmX75mm (1/2 Module)
Supplying and fixing following modular switch, socket, other accessories on the existing modular plate & switch box including connections but excluding modular plate etc. as per specification. 5.4.7 6 pin 20 amp socket outlet
Fan regulator (two module size) electronic stepped type moving all rounds
Plug Top (Deluxe type) 3 pin 16 Amps (For power plug).
RJ-45 {CAT6} socket outlet
RJ-45 {CAT6} LAN, I/O Box
Telephone socket outlet
T.V. antenna socket outlet
Computer Outlet Jack
25/32 amp A.C. Starter switch
Batten/ angle holder
Blanking plate
Key Tag Switch 32 amp with face and grid plate
Key Holder/Tag for key tag
USB charger socket 2.1 A
Providing and fixing composite unit for computer points having modular type 1 No 6 pin 16 amp socket outlet, 1 No 16 amp switch, 3 Nos 3 pin 6 amp socket outlets, 3 Nos 6 amp switches, suitable G.I. box, base and cover plates, earthing the sockets and switch box including etc. as per specification.
Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts A.C. supply, complete as required.5.7.2 Deluxe
Providing and fixing round/ hexagonal fan box (125mm dia) depth 75mm (max.) with 12mm dia steel bar hook, 1.6mm thick MS sheet cover, in RCC slab etc. as per specification.
Supplying, installation, testing and commissioning of premium quality Decorative ceiling fan having modern designer blades, good airthrow and with atleast two colour rendering effect along with unique smooth flowing canopies and down rod sleeve covering, wider blades at tips giving conical air throw including remote control for following sizes ceiling fan including wiring the down rods of standard length up to 30 cm with 1.5 sq. mm FRLS PVC insulated , copper conductor, single core wire, earthing etc. complete as per specification. P.F. should be greater than 0.9, with BEE Star rating from 3 star and above, IS: 374:2019 including all amendments 6.2.2 1200 mm sweep
Supplying, installation, testing and commissioning of following sizes Pedestal fan with telescopic arrangement for height adjustment and standard wiring/connection etc complete as per specification. P.F. should be greater than 0.9 6.3.1 400 mm sweep
Supplying and fixing of wall/ cabin fan including connection etc. as per specification. P.F. should be greater than 0.9 6.5.2400 mm sweep
Supplying, installation, testing and commissioning of following sizes heavy duty (continuous running) 1400 rpm exhaust fan in existing opening in wall including earthing etc. complete as per specification. P.F. should be greater than 0.9 6.6.2 380 mm sweep
Supplying, installation, testing and commissioning of following sizes fancy exhaust fan having built in louvers in existing opening in wall including earthing etc. complete as per specification. P.F. should be greater than 0.9 6.8.1 225 mm sweep
Supplying, installation, testing and commissioning of following LED fitting (luminaries) Panel Light in round/ square shape complete with electronic driver heat sink capacitor and all other accessories on surface/ in false ceiling etc. as per specification and P.F. should be greater than 0.9. LED chip efficacy ratio ≥ 100 lumens /watt. 6.15.4 12 Watt
Supplying, installation, testing and commissioning of following sleek LED panel down lighters (luminaries) in round/ square shape complete with electronic driver heat sink capacitor and all other accessories on surface/ in false ceiling etc. as per specification and P.F. should be greater than 0.9. LED chip efficacy ratio ≥ 100 lumens /watt. 6.16.2 36 watt, size 600 x 600mm
Supplying, fixing, testing and commissioning of following LED lamps with inbuilt electronic driver heat sink and all other accessories in existing holder/ luminaries as per specification and P.F. should be greater than 0.9. LED chip efficacy ratio ≥ 100 lumens /watt. 6.17.5 12 Watt
Supplying, installation, testing and commissioning of following COB LED Spot Light fitting complete with Electronic Driver Heat sink Capacitor and all other accessories including connection, earthing etc complete as per specification and IP20, P.F. should be greater than 0.9. LED chip efficacy ratio ≥ 100 lumens /watt. 6.18.2 9 watt
Supplying, installation, testing and commissioning of following LED tube light fitting including batten with Electronic Driver Heat sink Capacitor complete with all other accessories on surface/ in false ceiling, including connection, earthing etc complete as per specification and IP20, P.F. should be greater than 0.9. LED chip efficacy ratio ≥ 100 lumens /watt. 6.19.2 10 watt {2 feet}
36 watt {4 feet}
Supplying, fixing, testing and commissioning of following LED lamps {Inverter Type: with builtin battery backup} with inbuilt electronic driver heat sink and all other accessories in existing holder/ luminaries as per specification and P.F. should be greater than 0.9.LED chip efficacy ratio ≥ 100 lumens /watt. 6.20.2 12 Watt
Supplying, installation, testing and commissioning of following 230/250 volts LED BOLLARD fitting cool white/warm white {Colour Temperature 3000/4000/5600/6000 K} with electronic driver, heat sink, capacitor and all other accessories on existing foundation/ pole bracket, including connection, earthing etc complete as per specification. P.F. should be greater than 0.9. LED chip efficacy ratio ≥ 100 lumens /watt. 6.22.1 9 watt
Supplying, installation, testing and commissioning of following 230/250 volts LED Post Top Lantern fitting with perplex cover/decorative diffuser, electronic ballast and all other accessories on existing gate column/ pole bracket, including connection, earthing etc complete as per specification and P.F. should be greater than 0.9 . LED chip efficacy ratio ≥ 100 lumens /watt. 6.23.2 40 Watt
Supplying, installation, testing and commissioning of following LED Strip Light fitting complete with Electronic Driver Heat sink Capacitor and all other accessories, including connection, earthing etc complete as per specification and P.F. should be greater than 0.9. LED chip efficacy ratio ≥ 100 lumens /watt. IP-65 6.25.1 5 watt per metre LED Strip
Supplying, installation, testing and commissioning of following LED Signage entry/exit having minimum size 300mm (L) x 200mm (H) x 45mm (W), fitting complete including built in battery backup for 2 hour with Electronic Driver Heat sink Capacitor and all other accessories, including connection, earthing etc complete as per specification and P.F. should be greater than 0.9. LED chip efficacy ratio ≥ 100 lumens /watt. IP-20 6.26.1 Single sided LED Signage
Supplying, installation, testing and commissioning of following LED Bulk Head fitting complete with Electronic Driver Heat sink Capacitor and all other accessories, including connection, earthing etc complete as per specification and P.F. should be greater than 0.9. LED chip efficacy ratio ≥ 100 lumens /watt. IP65 6.27.1 10 watt
Supplying, installation, testing and commissioning of following 230/250 volts LED street light fitting with all accessories like driver, heat sink made of die cast aluminium with IP 66 protection and 15 KV surge protection on pole bracket, including connection, earthing, Separate housing for driver etc complete as per specification and P.F. should be greater than 0.9. LED chip efficacy ratio ≥ 120 lumens /watt. 6.28.8 90 watt
Supplying of following 230/250 volts LED Flood light fitting with all accessories like driver, heat sink made of die cast aluminium with IP 66 protection and 15 KV surge protection on pole bracket, including connection, earthing, Seperate housing for driver etc complete as per specification and P.A. should be greater than 0.9. LED chip efficacy ratio ≥ 120 lumens /watt. 6.29.4 80 watt
Supplying, installation, testing and commissioning of Acrylic LED light (a) Specification of Acrylic 3 mm thick x 3 " width x 4 " depth *(imbose) (b) Specification of LED modules :- Each Moduel should have 6 Nos LED of 1 watt
Fabrication and installation of angle iron including angle size 50 mm x 5 mm thick with labour charges including materials as per specification
Providing and fixing aluminium composite panels in approved panel sizes, thickness and shape on aluminium frame work 6.62.1 4 mm thick
Designing providing and fixing aluminium frame work made of special aluminium section on building face with M.S. angle iron brackets fixed on RCC structure with S.S. hold fasteners, including providing and fixing two sided structural adhesive tape of appropriate grade on aluminium section for fixing aluminium/glass panel, sealing on perihphery of frame work by providing EPDM gasket, silicon weather sealant between aluminium frame and building structure.
Supplying, installation, testing and commissioning of following LED fitting (luminaries) down lighters in round/ square shape shall be made up of Die Cast Powder coated housing complete with electronic driver ,heat sink and all other accessories on surface/ in false ceiling etc. as per specification. P.F. should be greater than 0.9 LED chip efficacy ratio ≥ 100 lumens /watt and Total harmonic distorsion (THD) of less than 10%. 6.69.3 12Watt
Supplying , installation , testiing and commissioning of following type Recessed LED Step Lighting fixture with IP66/65 protected Die-Cast Aluminum housing and Heat resistive Toughened Glass. LED shall having LM80 complied as per L70 standard LEDs minimum tested for 10,000 burning hours with 3000K CCTwith minimum life cycle 50000 hrs burning hours at 50˚C. Luminaire LED should have secondary Optic lenses. Driver shall be 3 stage Constant Current Constant Voltage with voltage range of 150-270V AC. Output voltage of driver should be complied to Safety Extra Low Voltage norms not exceeding 60V DC. Driver Power factor shall be 0.95 and above and THD shall be less than 10%. 6.79.1 3Watt
Providing and making interconnection in cubical panel between BBC and switchgears with following size aluminium strip of length upto 50cm as per specification (To be measured separately for each phase/ neutral). 7.16.1 20x5mm (100 amps)
30x5mm (200 amps)
50x5mm (300 amps)
50x6mm (400 amps)
75x6mm (500 amps)
80x6mm (600 amps)
100x10mm (1000 amps)
Providing and making interconnection in cubical panel between BBC and switchgears with following size FRLS PVC insulated copper conductor wire lead of length upto 50cm including providing copper thimbles on both ends as per specification (To be measured separately for each phase/ neutral). 7.17.1 10 sqmm (32 amp)
16 sqmm (63 amp)
Fabrication, supply, installation, testing and commissioning of cubicle type compartmentalized wall/ floor mounted power cum control panel board of specified size and following depth made out of not less than 2 mm thick CRCA MS powder coated sheet with suitable size compartments for bus bars, switchgears and necessary cutouts for voltmeters, ammeters etc as per specifications including powder coating painting but without busbars, switchgears and other accessories etc complete as per specification.7.19.1 Upto 300 mm deep
Above 300 mm and upto 450 mm deep
Above 450 mm and upto 600 mm deep
900 mm deep
Supply, installation, testing and commissioning of 4 pole (3 phase + neutral) aluminium bus bars in existing cubicle type compartmentalized wall/ floor mounted panel board along with suitable size and shape insulators, necessary bolts and nuts etc complete as per specification.7.20.1 100 amp (20x5mm)
200 amp (30x5mm)
400 amp (50x6mm)
600 amp (80x6mm)
1000 amp (100x10mm)
Providing and fixing following rating and breaking capacity MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 9.1.4 3 pole MCCB, 100A, Adjustable Thermal - Magnetic Release, 25KA
3 pole MCCB, 200A, Adjustable Thermal - Magnetic Release, 25KA
4 pole MCCB, 400A, Adjustable Thermal - Magnetic Release, 50KA
4 pole MCCB, 630A, Adjustable Microprocessor Release, 50KA
Supplying and fixing on surface/ recess horizontal type following way, 415 volts, TPN MCB distribution board of sheet steel phosphatized and powder painted, complete with tinned copper busbar, neutral busbar, earth bar, din bar, detachable gland plate, including interconnections, earthing etc. as per specification. (But without MCB/RCCB/Isolator) 9.4.1 4 way Single door
4 way Double door
6 way Double door
8 way Double door
Supplying and fixing SP MCB, 240 volts, 'B' curve, suitable for lighting and other loads in the existing MCB DB complete with connections, testing and commissioning etc. as per specification. 9.10.1 6 amps to 32 amps
Supplying and fixing SP MCB, 240 volts, 'C' curve, suitable for inductive load in the existing MCB DB complete with connections, testing and commissioning etc. as per specification. 9.11.2 6 amps to 32 amps
Supplying and fixing TP&N MCB, 440 volts, 'C' curve, suitable for lighting and other loads in the existing MCB DB complete with connections, testing and commissioning etc. as per specification. 9.16.2 6 amps to 32 amps
Supplying and fixing TP&N MCB, 440 volts, 'D' curve, suitable for inductive/ motor load in the existing MCB DB complete with connections, testing and commissioning etc. as per specification. 9.17.5 63 amps
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current up to 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as per specification. 9.22.3 63 amps
Providing and fixing approved make, Electrically Operated, draw out type, 415/500 volts, 4 pole Air circuit breaker complete with all standard accessories as per manufacturers specifications including drilling holes on the board, connections, earthing the body, testing and commissioning etc. as per specification and Ics = Icu = Icw for 1 second, IS/IEC: 60898. 10.2.1 800 amps, 4 pole, 50 KA
Providing installation testing and commissioning of approved make, 11 KV 1600 amp out door type VCB as per IS 13118 and additional specification suitable for use on 11KV 3 phase 50 Hz AC supply with rated capacity 26.3kA for 3 Sec insulation level 28 kV rms 75 kV peak with heater and spring charging motor operatable on 230 V AC supply complete with all standard accessories as per manufacturers specifications on existing CC foundation (excluding the cost of CC foundation) including connections, earthing the body etc. as per specification.
Providing and fixing metal clad, TP&N motorized change over switch unit, 415/500 volts, including drilling holes on the board, connections, earthing the body, testing and commissioning etc. as per specification.10.8.6 630 amps
Providing and fixing 3 pole, 415/500 volts following rating (AC-1 Duty) power contactor in existing starter/ cubical panel including, connections, testing and commissioning etc. as per specification.10.13.2 40 amps
Providing and fixing following rating current transformer in existing cubical panel including, connections, testing and commissioning etc. as per specification. 10.15.2 100/5 amps
Providing and fixing penal mounting 230 volt LED type indicating lamp in existing cubical panel including, connections, testing and commissioning etc. as per specification.
Providing and fixing penal mounting digital type ammeter of size 100x100 (NS) in existing cubical panel including, connections, testing and commissioning etc. as per specification
Providing and fixing penal mounting 0-500 volt voltmeter of size 100x100 (NS) in existing cubical panel including, connections, testing and commissioning etc. as per specification.10.20.2 Digital type
Providing and fixing following Time switch (timer) in existing panel including connection, testing and commissioning as per specification. 10.22.1 Digital type
Analoge type
Supplying, installation, testing and commissioning following rating single phase in single phase out ON-LINE UPS including connection etc but without batteries as per specification. 11.2.2 3 KVA with DC bus voltage 72 V
5 KVA with DC bus voltage 180 V
Supplying, installation, testing and commissioning following rating (Sealed Maintenance Free) lead acid battery including connection as per specification.11.4.2 65AH
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal and salt as per specification and IS Code 3043: 1987(R 2016)
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe, with charcoal and salt as per specification and IS Code 3043: 1987(R 2016)
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe, with charcoal and salt as per specification and IS Code 3043: 1987(R 2016)
Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode at 0.5 Metre depth below ground level including excavation and refilling the trench etc. as per specification.
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as per specification.
Supplying and laying 25 mm X 6 mm G.I. strip at 0.50 metre below ground as strip earth electrode, including soldering, excavation and refilling the trench etc. as per specification.
Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode at 0.5 Metre depth below ground level including excavation and refilling the trench etc. as per specification.
Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode at 0.5 Metre depth below ground level including excavation and refilling the trench etc. as per specification.
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as per specification.
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as per specification.
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ concealed conduit/ submain wiring/ cable as per specification.
Providing maintenance free earthing with following size GI pipe including making bore pit of minimum 150mm dia, providing and laying approved make Earthing Electrode of Pipe-in-Pipe technology as per IS 3043(R 2016) -1987 made of corrosion free G.I. Pipes having outer pipe of 80mm dia and inner pipe of 50mm dia and filling with specified qty highly conductive compound around pipe and above that with soft soil in bore pit complete and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. as per specification: 12.19.1 With 3 metre long GI Pipes and 50 kg back filling compound.
With 2 metre long GI Pipes and 25 kg back filling compound.
Excavation for foundation in soft soil/hard soil including dressing of sides and ramming of bottoms, lifting and getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 metres
Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate having 4 nos holes for fixing etc. complete as per specification.
Making jointing of G.I. tape (with another G I tape, base of the finial or any other metallic object) by reverting, sweating and soldering/ nut bolting of as per specification.
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as per specification.(For horizontal run)
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as per specification.(For vertical run)
Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as per specification.
Providing and laying G.I. tape 32 mm X 6 mm from earth electrode directly in ground as per specification.
Supplying and laying ISI marked double wall HDPE pipe (IS 14930 Part II) having corrugation on the outer wall and plan surface on inner wall in ground below road, path etc at a depth not less than 40 cm and upto 90 cm including excavation, dismantling of road if required and refilling the trench with excavated material, ramming and making the surface good etc. as per specification. 14.1.1 63 mm outer dia and 50 mm Inner dia
180 mm outer dia and 152 mm Inner dia
Supplying and laying following size medium class G.I. pipe in ground below road, path etc at a depth not less than 40 cm and upto 90 cm including excavation, dismantling of road if required and refilling the trench with excavated material, ramming and making the surface good etc. as per specification. 14.3.2 80 mm internal dia
100 mm internal dia
150 mm internal dia
Supplying and laying following size RCC Hume pipe class NP-2 (in standard length of 2 metre) with collar in ground below road, path etc at a depth not less than 50 cm and upto 90 cm including excavation, dismantling of road if required and refilling the trench with excavated material, ramming and making the surface good etc. as per specification. 14.4.1 100 mm dia
150 mm dia
200 mm dia
Supplying and laying following sizes one number FRLS PVC insulated/XLPE, PVC sheathed, steel armoured, aluminium conductor power cable of 1.1 KV grade direct in ground at a depth not less than 40 cm and upto 90 cm including excavtion, sand cushioning, protective covering and refilling the trench etc as per specification, IS: 1554 (1988, Part 1) / IS: 7098 (1988, Part 1). 15.1.11 3.5 x 25 sq. mm.
3.5 x 70 sq. mm.
3.5 x 120 sq. mm.
3.5 x 150 sq. mm.
3.5 x 240 sq. mm.
4 x 16 sq. mm.
Supplying and laying following sizes one number FRLS PVC insulated /XLPE, PVC sheathed, steel armoured, aluminium conductor power cable of 1.1 KV grade in existing RCC/ HUME/ STONEWARE/ METAL/ HDPE pipe as per specification, IS: 1554 (1988, Part 1) / IS: 7098 (1988, Part 1). 15.3.2 2 x 6 sq. mm
4 x 10 sq. mm.
4 x 16 sq. mm.
Supplying and making end termination with brass compression gland and aluminum lugs for following size armoured aluminum conductor power cable of 1.1 KV grade as per specification. .15.23.2 2 X 6 sq. mm (16 mm)
3½ X 25 sq. mm (25 mm)
3½ X 70 sq. mm (35 mm)
3½ X 120 sq. mm (45 mm)
3½ X 150 sq. mm (45 mm)
3½ X 240 sq. mm (57 mm)
4 X 10 sq. mm (22 mm)
4 X 16 sq. mm (22 mm)
Supplying and laying one number following sizes XLPE, steel armoured, aluminium conductor power cable of 11 KV grade direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as per specification and IS: 7098 (2011, Part 2). 16.1.6 3 x 150 sq mm
Supplying and making INDOOR cable end jointing with heat shrinkable cable jointing kit including lugs and other jointing materials, for following size of 3 core, PILC aluminum conductor cable of 11 KV grade as per specification: 16.12.6 150 sq. mm
Supplying and making OUTDOOR cable end jointing with heat shrinkable cable jointing kit including lugs and other jointing materials, for following size of 3 core, PILC aluminum conductor cable of 11 KV grade as per specification:16.13.6 150sq.mm
Supplying and installing following size of perforated hot dipped Galvanised Iron cable tray (Galvanisation thickness not less then 50 microns) with perforation not more than 17.5% rigidly suspended from the ceiling with G.I. suspenders at a distance not more than 2.5 metre and near every junction/ joint etc complete as per specification.18.4.2 150 mm width X 50 mm depth X 1.6 mm thickness
300 mm width X 50 mm depth X 1.6 mm thickness
Supplying and fixing of following size of perforated hot dipped Galvanised Iron (Galvanisation thickness not less then 50 microns) cable tray "bends" (horizontal) turning at 90º in same plane with perforation not more than 17.5% rigidly jointed with cable tray etc. complete as per specification. 18.5.2 150 mm width X 50 mm depth X 1.6 mm thick
300 mm width X 50 mm depth X 1.6 mm thick
Supplying and fixing of following size of perforated hot dipped Galvanised Iron (Galvanisation thickness not less then 50 microns) cable tray "bends" (vertical) turning at 90º in same plane with perforation not more than 17.5% rigidly jointed with cable tray etc. complete as per specification.18.6.2 150 mm widthX50 mm depthX1.6 mm thick
300 mm widthX50 mm depthX1.6 mm thick
Supply of hot dipped galvanized (in single dip to minimum 75 micron) octogonal pole made of 3mm thick steel grade E-350 sheet having window and flush cover with locking arrangement at suitable height from base for cable termination block, pole suitably reinforced with welded steel section at window cut section to make the strength of pole unaffected, with following minimum specifications with 4 way terminal connector including 3mm thick anchor plate, 4 nos 20mm dia foundation bolts of EN8 grade, and as per IS 2062 & BS EN: 10025. (designed for wind speed upto 180km/hr, IS: 875 Part 3) 19.7.2 7 metre high, dia 130mm at bottom and 90mm at top, base plate size 220x220x12mm, foundation bolts 700mm long
Supply of hot dipped galvanized (in single dip to minimum 75 micron) octogonal pole made of 3mm thick steel grade E-350 sheet having window and flush cover with locking arrangement at suitable height from base for cable termination block, pole suitably reinforced with welded steel section at window cut section to make the strength of pole unaffected, with following minimum specifications with 4 way terminal connector including 4mm thick anchor plate, 4 nos 24mm dia foundation bolts of EN8 grade, and as per IS 2062 & BS EN: 10025. (designed for wind speed upto 180km/hr, IS: 875 Part 3) 19.8.4 12 metre high, dia 240mm at bottom and 90mm at top, base plate size 320x320x20mm, foundation bolts 850mm long
Supply and fixing following street light pole bracket on existing pole made out of 50 mm dia MS "B" class pipe welded to 300 mm long MS pole canopy of suitable dia at a angle of 102.50 including having MS triangular stiffner of size 150 X 50 X 5 mm thick, making arrangement for tightening the bracket with pole by providing suitable size heavy duty nuts and bolts in canopy, painting with one coat of approved steel primer etc. as per specification.19.9.2 Single Over Hang 1.00 metre Long
Double Over Hang 1.00 metre Long
Erection of GI octogonal/ tubular/conical pole on existing cement concrete foundation having grouted bolts and nuts, aligning in true vertical position as per specification. 19.11.5 7 metre high
12 metre high
Designing and providing suitable RCC foundation in Cement Concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) for 3 mere to 12 metre high GI octagonal pole including steel reinforcement form work, embeding 2 nos 50mm dia PVC pipe for cable entry in each foundation, excavation disposal of surplus soil and curing etc. as per specification.
Providing and making suitable CC pole collar (muffing) in Cement Concrete 1:3:6 (1 cement: 3 coarse sand: 6 graded stone aggregate 20 mm nominal size) of size 0.4 m dia and 0.4 m height from existing CC foundation.
Supplying and fixing PVC water tight terminal box of approved make and brand with detachable gland plate in bottom, hinged front openable cover, rubber gasket, having 1 Nos 4way connector and 1 No SPMCB inside the box for cable connection, fixed to pole with 2 Nos clamp made from 25x3mm GI flat with 2 No GI nuts bolts complete as per specification. 19.17.1 250x200x125 mm for single phase
300x200x125 mm for 3 phase
Supplying erection testing and commissioning of hot dipped galvanised (single dip, minimum 86 micron) 12 metre High mast pole on existing RCC foundation with all accessories and equipments, main detailed as below to withstand max wind pressure as per IS 875 Part-3: a) HM shaft made of approx weight 340 kg, sheet thickness 3 & 4 mm, nominal dia 360mm on bottom and 150 mm on top, base plate 25mm thick 520mm dia, approved no of sections (not more than 2) having suitable sectional lengths with slip joints between sections without any circumpherencial welding. b) Double drum winch with Integral single phase power tool (electrical) for lowering & raising of lantern carriage on high mast with separate handle for manual operation of winch with a torque limiting device for safe locking of carriage. c) Raising/lowering type lantern carriage designed to carry specified nos of luminaries, control gear box, junction box. d) Top pulley assemble with weather proof cover. e) Necessary suitable length and size stainless steel wire ropes (minimum 6mm dia and 7/19 construction) for lowering & rising of lantern carriage. f) Suitable size and length multicore flexible copper power trailing cable (minimum 6 sqmm) g) Hinged service door in base section h) Base plate earthing terminal. i) Suitable arrangement for supply distribution with termination of suitable size underground cable in high mast. j) Lightning conductor finial made of 25mm dia 300 mm long G.I.tube having single prong. k) Anchor plate, tem-plates, GI foundation bolts min 6 Nos of 24mm dia 750 mm long (EN 8 Grade) along with nuts washers etc. (RCC fooundation and luminaries will be paid separately)
Supplying erection testing and commissioning of hot dipped galvanised (single dip 86 micron) 16 metre High mast pole on existing RCC foundation with all accessories and equipments, detailed as below to withstand wind pressure upto 180km/hr and minimum following specifications: a) HM shaft made of not more than 2 sections of suitable lengths with telescopic stressfit joints between sections without any circumpherencial welding, sheet thickness 4mm top and bottom sections, nominal dia 460mm on bottom and 150 mm on top, base flange 25mm thick 670mm dia, PCD of foundation bolts 650mm. b) Double drum winch for lowering & raising of lantern carriage on high mast with operatable with power tool/ manual handle attachment with a torque limiting device for safe locking of carriage. c) Raising/lowering type lantern carriage designed to carry specified nos of luminaries, control gear box, junction box. d) Top pulley assemble with weather proof cover. e) 3 Nos suitable length and size stainless steel wire ropes (minimum 6mm dia and 7/19 construction) for lowering & raising of lantern carriage. f) Suitable size and length multicore flexible copper power trailing cable (minimum 3 core 4 sqmm) g) Hinged service door in base section h) Base plate earthing terminal. i) Suitable arrangement for supply distribution with termination of suitable size underground cable in high mast. j) Lightning conductor finial made of 25mm dia 300 mm long G.I. tube having single prong. k) Anchor plate of size 840x840x6mm, tem-plates 3mm thick, GI foundation bolts 8 Nos of 30 mm dia 850 mm long (EN 8 Grade) along with nuts washers etc. (RCC fooundation and luminaries will be paid separately)
Designing and providing suitable and approved size RCC foundation for 12-30 metre high mast including seel reinforcement form work, embeding 2 nos 50mm dia PVC pipe for cable entry in each foundation, excavation disposal of surplus soil and curing etc. as required including laying and fixing HM foundation bolts with tam plates but excluding the cost of foundation bolts with tam plates etc complete as per specification
Painting of following height steel tubular poles with two coat of approved colour and shade synthetic enamel paint including cleaning the surface as per specification: 19.24.2 Above 6 metre and upto 8 metre
Above 12 metre and upto 14 metre
Supplying and installation of outdoor type Transformer ONAN type with copper winding having following continuous KVA rating, 11 /0.415 KV, 3 Phase 50 Hz Vector group DYn-11, (Online tap changer) tapings in steps of ± 2.5%, ± 5%, --7.5% with oil conservator, silica gel breather having connecting terminals on HV side suitable for bare conductor/HT cable connection, cable end box on medium voltage side suitable for 1.1 KV single / 3½ core cable(upto 300 sq mm)/bus ducting arrangment and confirming to IS:1180 Part-2 Level 3, on existing double pole structure or Brick /CC/RCC platform with all fittings, accessories, filled with filtered transformer oil including testing and commissioning etc. complete as per specification 21.1.7 500 KVA
Supplying, installation, testing and commissioning of following capacity diesel Generating Set (alternator directly coupled to diesel engine) compete in all respect broadly comprising of following and as per CPCB 2 norms (upto date ammended), including following specification. A. Alternator : Self excited, brush less type, of following capacity, 3 phase, 415 volts 50 Hz, 4 pole, AC alternator complete with all accessories.B. Engine : water cooled diesel engine of suitable BHP for rated alternator at 1500 rpm, turbo charged, direct injection type, 4 stroke, 4/6 cylinder including specified size fuel tank of approved design and shape duly calibrated and painted with one coat of primer and two coats of synthetic enameled paint of approved colour, residential type silencer with exhaust MS pipe (upto 2 metre beyond silenser) duly wrapped with asbestos rope of legging of specified quality and specification.C. AMF Panel : Cubical, compartmentalized, AMF panel board with all suitable size power and control contactors, switches, meters and other accessories, internal wiring, connection, inter-connection etc. for trouble free smooth functioning of DG Set complete with battery charger and leads as per specification.D. Base Plate : Common base plate of required size for mounting of engine alternator set fabricated from MS channel and vibration damping arrangement with cushy foot mounting i/c painting etc. as per specification. 21.3.13 300 KVA
Supplying, installation, testing and commissiong of following size {storage volume } domestic refrigarator with BEE star rating,copper coil and eco friendly refrigerant, suitable puff insulation, built in voltage stabilizer and power saver compressor, conformity to IS: 1476, including all accessories connection etc complete as per specification. 24.21.3 360 ltr.
Providing of Core cut with suitable size as per specification at site.
Supplying, installation, testing and commissiong of following size drinking water cooler storage type ISI marked, eco friendly non CFC refrigarant, water tank and cooler cabinet sheet material- stainless steel {grade AISI 304} with thickness>= 0.8 mm, with PUF insulation including all accessories connection etc complete as per specification. 24.23.2 60/120 Ltrs/hr
150/150 Ltrs/hr
Supplying, installation, testing and commissiong of following capacity of RO purification system with UF/UV/TDS controler and UV lamp {IS 14724 Ultra voilet disinfection} and minimum three stage purification, automatic on/off, output water conferming standard IS 10500 with inbuild storage tank including all accessories connection etc complete as per specification. 24.24.1 25 Ltrs/hr output capacity
50 Ltrs/hr output capacity
Supplying and fixing wall mounted storage/instantaneous type electric geyser, complete with inner copper container, heating element, thermostat, indicating lamp including inlet / outlet water pipe connection, electric connection testing and commissioning etc. as per specification. 24.26.2 3 Ltr Capacity Instantaneous water geyser 5 star
15 Ltr. Capacity storage type geyser 5 star
25 Ltr. Capacity storage type geyser 5 star
Supply, installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as per specification. 25.29.1 Thickness 0.63 mm sheet
Thickness 0.80 mm sheet
Thickness 1.00 mm sheet
Supplying & fixing of powder coated extruded aluminium Supply Air Grills with aluminium volume control dampers as per specifications.
Supplying & fixing of powder coated extruded aluminium Return Air Grills with louvers but without volume control dampers complete as per specification.
Supplying, fixing testing commissioning of supply air diffusers of powder coated aluminium with aluminium volume control dampers with anti smudge ring & removable core.
Supplying, fixing testing commissioning of Return air diffusers of powder coated aluminium without volume control dampers with anti smudge ring & removable core.
Supply installation,testing & commissioning of modular type variable refrigerant flow/variable refrigerant volume air cooled outdoor units suitable for cooling and heating, having all hermetically sealed inverter type scroll compressor(s), minimum two compressors for above 14HP modules, microprocessor based controller, top discharge type condensing unit(s), with R410a refrigerant, vibration isolators, with suitable foundation etc. Complete as per specification. The unit shall deliver the rated capacity at AHRI conditions and work even at 50°C ambient temperature without tripping. The unit shall be suitable to work on 400v +/-10%, 3phase, 50Hz AC power supply. The unit shall be filled with first charge of the refrigerant and ready for use as per specification. The COP at AHRI conditions shall not be less than 3.1 and IEER not less than 6.5 Indoor Unit Cassete type
Supply, installation, testing and commissioning of following minimum capacity 4-Way flow VRV/VRF Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fansection with low noise fan/dynamically balanced blower, multispeed motor, coilsection with DX Copper coil, electronic expansion valve, outer cabinet, drainpump, grill, necessary supports, vibration isolation, cordless remote control etc., suitable for operation on single phase 230V±10%, 50Hz AC supply, complete, as per specification. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19Degree C WB temperature. 25.46.4 2.6- 3.3. TR
Supply, installation, testing and commissioning of following minimum capacity and external Static pressure VRV/VRF Ceiling Mounted Ductable Type Indoor unit equipped with synthetic washable media pre-filter, fansection with low noise fan/dynamically balanced blower, multispeed motor, coilsection with DX Copper coil, electronic expansion valve, outer cabinet, vibration isolators, cordless remote control, drain pan, other necessary accessories/Supports etc., suitable for operation on 230V±10%, 50Hz single phase AC supply, complete, as per specification. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature. Mid Static Ductable Unit {Minimum 45 Pascal external static Pressure } 25.48.5 2.3 TR
Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc. as per specification : 25.51.1 6.4 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation
9.5 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation
12.7 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation
15.9 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation
19.1 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation
22.2 mm dia (OD) (Hard drawn)with tube thickness 1.2 mm with 19 mm thick insulation
25.4 mm dia (OD) (Hard drawn)with tube thickness 1.2 mm with 19 mm thick insulation
28.6 mm dia (OD) (Hard drawn)with tube thickness 1.2 mm with 19 mm thick insulation
31.8 mm dia (OD) (Hard drawn)with tube thickness 1.62 mm with 19 mm thick insulation
34.9 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm with 19 mm thick insulation
38.1 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm with 19 mm thick insulation
41.3 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm with 19 mm thick insulation
Supplying and installation of Refnet Joints as per site conditions.
All Control /communication wiring between indoor and Outdoor Units with FRLS PVC conduit and necessary clamps/saddling etc. complate as requird.
Supplying, laying, fixing and installation of rigid PVC drain piping of 6 KG/sqcm, duly insulated with 6/9 mm thick nitrile rubber pipe section, complte with all necessary fitting such as elbows, tees, reducers, serviceable "P" traps etc. and supports such as clamps etc. complate as per specifications.25.55.1 25 MM DIA
32 MM DIA
40 MM DIA
50 MM DIA
Supplying and fixing of Acoustic insulation with 6 mm thick resin bonded fiber glass Rigid Board density not less then 48KG/cu.mtr density coverd with R.P. tissue paper and 24G Perforated aluminium sheet having 3mm perforations at 6mm centers.
Supplying and fixing of 19mm thickness closed cell Nitrile rubber (Class "O") insulation for Supply air duct on existing duct after applying suitable adhesive for Nitrile rubber. The joints shall be sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape insulation complete as per specification.
Supply, installation, testing and commissioning of GI Volume Control Collar/ duct Dampers Complete with neoprene rubber gaskets. Nuts Bolts, screw linkages, flanges etc., as per Specifications
Supply & fixing Of MS stand for outdoor units
Supply & fixing Of Branch Kit Joints.
SITC Of VRV System including topping R-410 gas as per site requirements. Refrigerant shall be environment Friendly R-410
Supply, Installation, Testing & Commissionig of flexible {canvas} connection between duct and Machine
Supply, Installation, Testing & Commossionig of Control Cum Transmission Wiring in suitable conduits between indoor & outdoor units &for remote including supply of screendwires, Supports, installation, saddles, ties, tags, ferrules, lungs, nuts/bolts/hardware etc.complete in all aspects as per specifications & any other items required to make the system complete. 25.72.1 2C X 1.0 Sq mm Copper
Supply, Installation, Testing and commissioning of factory built floor/ceiling mounted DX type double skin type horizontal/vertical air handling units made of 25mm thick panels consisting of pre plasticized G.I. casing of thickness 0.8mm outside layer and 0.8 mm inside layer with polyurethane foam (PUF) insulation (having density 48 kg/cu m) factory injected between them by injection moulding machine, complete with blower section with blower suitable for static pressure as per specification, minimum 4 bend GSS/PVC eliminators, DX type cooling coil section with aluminium finned copper tubes (tubes thickness not less than 0.5mm) cooling coil of 6 row deep, filter section with 50mm thick metal viscous/ washable synthetic type air prefilters, belt drive package with TEFC drive motor of efficiency class IE3 suitable for 415 ± 10% volts, 50Hz, 3 Phase AC supply suitably designed for varialbe frequency drive applications, drain connections, stainless steel (18G) drain pan with PUF insulation, 150 mm dia. dial type pressure gauges (2 nos.)and industrial type thermometers (2 nos.) at the inlet and outlet of coil, auto purge valve wherever required, including starter Pannel of suitable capacity, necessary vibration isolation arrangement, with mixing Box etc. complete as per specification and of following capacities. 25.74.1 5000 CFM - 65 mm Static Pressure
7000 CFM - 65 mm Static Pressure
20000 CFM - 65 mm Static Pressure
Suppying , installation , testing and commissioning of Fire alarm Control panel (UL Listed) suitable for 252 addressable points (Detector & Devices). Comprising of the following system components: Operating units, Periphery boards, Power supplies,System enclosures, with battery backup 24hours and 30minutes,
Suppying , installation , testing and commissioning of Intelligent Addressable Type Manual Call Point: Intelligent Manual Fire Alarm Box is constructed of durable, molded and polycarbonate material that is matte finished in red with raised white lettering Single-action,Pull-down lever is down, until manually reset,Polarity insensitive via SureWireTM technology
Suppying , installation , testing and commissioning of Short circuit Isolator Base: Local light-emitting diode (LED) indicator UL 864 9th Edition Listed and ULC Listed; FM Approved
Suppying , installation , testing and commissioning of Response Indicator for above false ceiling detector
Suppying , installation , testing and commissioning of Intelligent Addressable Relay control module for Hooter Interfacing and supervising normally open (N.O) or normally closed (N.C) contacts,Integral single-pole, double-throw (SPDT) relay (up to 4 amps) ,Multi-color light-emitting diode (LED) indicates system status, UL Listed & ULC Listed; FM Approved
Suppying , installation , testing and commissioning of 2 core x 1.5 sq.mm Armoured FRLS fire cable
Supply and erecting of following ISI marked Fire extenguishers on wall/ column including erecting bracket etc complete. 26.17.2 ABC Fire Extinguisher 6KG Nitrogen Store Pressure As per IS: 15683:2018 Body Sheet Not Less Then 2mm Thickness, CE Mark NRV Valve With ABC Powder 90% UL 299 FIRE RATING: 4A, 144B. With all accessories.
CO2 type Fire Extinguisher ISI marked confirming to IS:15683:2018 Capacity 4.5Kg. INITIAL CHARGE:- Carbon dioxide used in extinguishers shall comply with IS 15222. FIRE RATING:- 55B. Complete with Hose Assembly and horn , locking arrangement, operation manual, bracket with two screw and sleeve
Supplying , installation , testing and commissioning of 2 MP Bullet Camera weather & dust proof IP based Fixed Lens day/night Camera (IP67 , IK 10) , 2 MP CMOS Image Sensor ,H.265 and H.264 triple-stream WDR(120dB), Day/Night, UL ,CE FCC Certified as per the specifications.
Supplying , installation , testing and commissioning of 4 MP Bullet Camera weather & dust proof IP based Fixed Lens day/night Camera (IP67 , IK 10) , 1/3” 4MP PS CMOS Image Sensor, H.265 and H.264 triple-stream encoding, WDR(120dB), Day/Night Support, UL ,CE FCC Certified as per the specifications.
Supplying , installation , testing and commissioning of 2 MP DOME Camera weather & dust proof IP based Fixed Lens day/night Camera (IP66) 2Megapixel CMOS Image Sensor,H.265 / H.264 triple-stream encoding , WDR(120dB), Day/Night UL, CE, FCC Certified as per the specifications.
Supplying , installation , testing and commissioning of 32 Channel NVR 8 Sata Port Up to 32 channel IP camera input , Max 320Mbps incoming bandwidth , Smart H.265+/H.265/Smart H.264+/H.264/MJPEG , Up to 12MP resolution preview and playback , Support 8 SATA HDDs up to 10TB each,1 eSata , 4 USB(2 USB3.0, 2USB2.0) , 2 HDMI / 2 VGA simultaneous video output ,ONVIF Version 2.4 conformance , Alarm In / out 16/6 , Two way talk 1 Channel Input, 2 Channel Output RCA , 1 RS485, 1 RS232 , 2 RJ-45 port (10/100/1000Mbps), Support ANPR Camera as per the specifications.
Supplying , installation , testing and commissioning of 8 Port Managable PoE Switch 10/100/1000 8 Port with 2 Giga SFP uplink, L2 Managed PoE switch , Power Budget max 96 W , single port 30 W ,AI Extend , AI VLAN as per the specifications.
Supplying , installation , testing and commissioning of 16 Port Giga PoE switch 10/100/1000 16 Port with 2 Giga SFP uplink, PoE switch Power Budget 150 watt ,Single Port Max 30W , AI Extend ,AI VLAN as per the specifications.
Supplying , installation , testing and commissioning of 8 TB Surveillance Hard disk drive Complete as required
Supplying , installation , testing and commissioning of 9U Indoor Rack Wallmount 9U 630D With Front Glass Door Lock & Key 550 9U - (with 1U cable Manager;Fan;6 socket PDU) complete as required.
Supplying, installation, testing and commissioing of following size LED Monitor, table/wall mount with inbuild speaker minimum 5Wx2,with minimum 1 No of HDMI and USB port including remote control, connecting cable, batteries, and all accessories, connection etc complete as per specification. 27.49.4 55 inch
Supply, installation and testing for HDMI cable.
Supply installation and testing for Media Convertor 10/100/ 1000 gigabit with specification TP Port Rate-10/100Mbps N-Way Auto-negotiation, Fiber Port Rate - 100Mbps Duplex Mode - Full-Duplex / Half-Duple N-Way Auto-negotiation UTP Ports -RJ-45 UTP Fiber Ports -SC Distance - 0~2 Kms LED Indicators - TX LINK, FX LINK, TX ACT, FX ACT, PWR, FDX.Power Requirement - 5VDC 2A Ambient Temp.- 0~60°C Humidity : 5%~90% Dimensions -95mm(W)×71mm(D)×27mm(H) FCC Part -15 Class A & CE Marks,
Supply installation and testing for SC-SC Patch Card for Optical Fiber Connector Type- SC / ST / FC / LC / MTRJ, Optical Fiber- Corning single-mode G652D, G657A, G657B, Cable Type- PVC & LSZH on request 0.9mm/2.0mm/3.0mm Simplex & duplex, Cable Color-yellow, Insertion Loss-≤0.2dB, Max. 0.3dB, Return Loss->PC≥45dB, UPC≥50 dB, APC≥60dB, Fiber Height-±100nm, Connector Ferrule Ceramic, (MTRJ: PS- Polyphenylene Sulphide )
Supply installation and testing for Patch Panel Fully Loaded with Specification of Standard 19” rack mount, accommodates 25x50 mm USO II modules, designation strips and white paper inserts, panel mounting screws and washers, White/writeable labels for port identification, Dimensions 1U USP Panel 44 mm x 483mm x 38mm
Supplying, installation, testing and commissioning of CAT 6 Patch Cord with specification of 4 Pairs Unshielded Twisted Pair (UTP) Cable, Conductor Metal: Bare Copper, Color Code: Gray Conductor: 24 AWG, Insulation Material: HD-PE, Jacket Material: PVC UL94V-0, Heat-resistant: 60oC minimum (Temperature limited), Flame property: The purpose of the vertical flame test is to screen out flammable wires. It follows the VW-1 (UL); FT-1 (CSA) standards.
Supply of 6 Core Armoured / Outdoor Optical Fiber cable Generally confirming to EIA/TIA 568-C.2 and IEC/ISO11801 Excellent Margin with suppression of Cross Talk (NEXT) 4 Pair Separator Design 23 AWG cable For Outdoor installation
Supply of Fiber Patch cord / Pigtail cableLC / UPC, LC / APCIL =< 0.3dB RL >= 50dB LC 2.0/3.0mm Simplex Patch CordLC 2.0/3.0mm Duplex Patch Cord Options with multimode
Supply, installation , testing and commissioning of OFC Junction Box Fully Loaded fiber Optic Joint Termination Enclosure Box with OFC Splicing Tray | JC BOX | Tiffin Type JC
Supplying , installation , Testing and Commissioning of UHF Wireless Cardioid Condenser handheld microphone system with Frequency Response of 60 Hz to 16 kHz , RF Sensitivity 10dBμV (S/N 60dB @ 20 kHz deviation) or better, Total Harmonic Distortion <1.0% (at 1 kHz, ±20 kHz deviation) or better, Dynamic Range > 108dB or better, on/off switch operating range 60 mtrs or better, RF Power Output: 10 mW or better, maximum Output level XLR / Balanced: +4 dBV & 6.3 mm (¼") / Unbalanced: -2 dBV with all necessery terminals and Connectors.
Supplying , installation , Testing and Commissioning of UHF Wireless Cardioid Condenser lapel microphone system with Frequency Response of 60 Hz to 16 kHz , RF Sensitivity 10dBμV (S/N 60dB @ 20 kHz deviation) or better, Total Harmonic Distortion <1.0% (at 1 kHz, ±20 kHz deviation) or better, Dynamic Range > 108dB or better, on/off switch operating range 60 mtrs or better, RF Power Output: 10 mW or better, maximum Output level XLR / Balanced: +4 dBV & 6.3 mm (¼") / Unbalanced: -2 dBV with all necessery terminals and Connectors.
Supplying , installation , Testing and Commissioning of Advanced digital audio processor with open architecture software-configurable functionalityComprehensive library of DSP algorithms optimised for installation applications, 8 Channels of wide band Acoustic Echo Cancellation (AEC) for telephone and video conferencing, Auto mixer functionality for multiple microphone applications, Optional Dante card for IP-based audio networking, PC-based software with intuitive graphical user environment, 10 high-headroom analogue universal mic/line inputs,6 electronically balanced low impedance line level outputs, USB audio connection for integration with computer based audio, ULTRANET digital audio transport output for connection to compatible devices Ethernet port for software configuration via CAT5/5e cable with all necessery terminals and Connectors.
Supplying , installation , Testing and Commissioning of Wall Mounted two way full Range speaker with Minimum 2 x 3.5" LF or 1 x 5.25" LF or better with 1" HF with a Frequency Response(-10dB):- 65Hz-20Khz & Long Term Program Power Handling of 120W or more. The Loudspeaker should have a Sensitivity(1W/1m) of atleast 90dB with a Max. Peak SPL of >114dB. Speaker shoudl have 70/100 volt transformer taps with upto 60 watts tapping. The Sound Dispersion should be 90x70 Degrees or better complete with wall mount Bracket of same OEM with all necessery terminals and Connectors.
Supplying , installation , Testing and Commissioning of Dual Channel Audio Amplifier Professional 1700-Watt (Per Channel 700 to 800 Watts into 4 Ohms OR Per channel 400 to 500 Watts into 8 Ohms OR 1600 to 2000 Watts into 8 Ohms (bridge mode)Stereo with all necessery terminals and Connectors.
Supplying , installation , Testing and Commissioning of EP 3.5 MM Connectors Pin with all necessery terminals and Connectors.
Supplying , installation , Testing and Commissioning of MXLR Connector Socket with all necessery terminals and Connectors.
Supplying , installation , Testing and Commissioning of FXLR Connectors Socket with all necessery terminals and Connectors.
Supplying , installation , Testing and Commissioning of Patch box with 04 connetors options for mic & stage monitor
Supplying , installation , Testing and Commissioning of 2.5Sq.mm Speaker cable Cross sec Area 1.5 sqmm, No of Strands 75 , Size of Strands 34 , Cond.Type ATC Speaker Cable - Copper 2Core, Twisted, Tin Coated, Shielded 2.5SQMM (70/.2) ATC 2/C SPEAKER CABLE 14AWG with all necessery terminals and Connectors.
Supplying , installation , Testing and Commissioning of Heavy Microphone Cable AWG NOM Insulation Dia. Shield NOM NOM Conductor Center Inches mm Construction Jacket Dia. Capacitance Resistance Canductor (Min.) Inches mm (Pf / mtr.) Ohm / km (Max.) 24 AWG 0.053 1.35 80% 0.232 5.9 68(Cond. To Cond.) 91.1 with all necessery terminals and Connectors.
Supplying , installation , Testing and Commissioning of Power Management (Constant Voltage / Frequency Stabliser): Power Conditioner, with a built in 3 Way Sequencer that provides sequenced switching with a fixed interval, turning them on & off ina preset sequence. Adjustable Protection Levels : Over voltage 245-275 VAC Under voltage 170-220 VAC with Disable %-Over Frequency 50.5-55.0 hz with Disable Under Frequency 45.5-49.5 hz with Disable with all necessery terminals and Connectors.
Supplying , installation , Testing and Commissioning of 17U Equipment Rack, with Metal Side Panel, Back Door, Front Glass Door, Floor Wheel, 15u PDU Unit, Cooling FAN, Cable Manager, Counter Shelf with all necessery terminals and Connectors.
Supplying , installation , Testing and Commissioning Cardioid Condenser Gooseneck Microphone with goosenck length of 415mm or more. Flexible gooseneck head for accurate positioning. Shock Mount to be inlcuded with Microphone from same OEM with Frequency Response 70 Hz - 16,000 Hz; It shall be capable of handling sound input levels up to 134 dB with a dynamic range of 106 dB. Nominal open-circuit output voltage shall be 12.0 mV at 1 V, 1 Pascal or better, Signal-to-noise ratio of 66dB,1kHz at 1Pa or better. Support 11V to 52V phantom power for operation. Impedance 100 ohms or better complete with Foam Windscreen with all necessery terminals and Connectors.
Supplying , installation , Testing and Commissioning Active Speaker 1100 Watt 2 Way 15" Full Range Powered Loudspeaker with DSP Technology Components 1 x 15" LF driver 1 x 1" HF driver Connectors Mic/Line input: combo jack/female XLR wired pin 2 hot Mix out: male XLR wired pin 2 hot Controls Level, Line/Mic, Low Cut, Speech/Music, Bass and Treble, Front LED, Mains on/off requency Range 45 Hz–18 kHz ±3 dB 40 Hz–20 kHz –10 dB Dispersion @-6 dB pts 90° H x 60° V Max SPL (peak) 130 dB Equalisation Bass: ±6 dB @ 80 Hz Treble: ±6 dB @ 12 kHz Max Output Power LF: 1000 W HF: 100 W with all necessery terminals and Connectors.
Supplying , installation , Testing and Commissioning 10‑channel Compact Mixing System, 10 input channels (6 Mic/Line + 4 mic/Stereo-Line), 2 High-Quality editable effects,MIC input to Master A L/R outputs, +16 dBu, typical < 0.01% Frequency Response, -3 dB, ref. 1 kHz, any input to any Mixer output 15 Hz to 20 kHz, Fader & FX/AUX/MON-Send attenuation > 75 dB Channel to Channel < -75 dB CMRR, MIC input, 1 kHz > 80 dB, Equivalent Input Noise, MIC input, A-weighted, 150 ohms -130 dBu with all necessery terminals and Connectors.
Earth work in all type soil except soft rock / hard rock with all lead and 1.5 metre lift, dressing, stacking excavated strata including refilling of excavated soil in trench / pit to ground level complete as per specification.
Earth work in soft rock with all lead and 1.5 metre lift, dressing, stacking excavated strata including refilling with excavated soil in trench / pit to ground level complete as per specification
Filling hard moorum in foundation or under floor in layers including ramming and watering.
Providing and laying Cast-in-situ cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm including mixing with mechanical mixer, compacting with vibrator, finishing and currying etc. complete but excluding form work.
Providing and laying Cast-in-situ cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40mm including mixing with mechanical mixer, compacting with vibrator, finishing and currying etc. complete but excluding form work.
Structural steel work in single section including cutting, hoisting, fixing in position and applying a priming coat of red oxide zinc chromate primer.
Applying priming coat on steel work with red oxide zinc chromate primer.
BSTUPTS
BSPUPTS
CGHCB
CHiPS
CGMSC
CGPHC
CGRBEKVN
CSIDC
CGSMB
CGMFPFED
CGSPDCL
CGSPGCL
CGSPTCL
CGSWC
CGTBC
DBUPTS
KRBAUPTS
KRYAUPTS
RIGUPTS
RUPTS
RNDGUPTS
SUPTS
hectare
joint
litre
Man-Month
meter
metre
one RCC jaali tree guard
one RCC jaali tree guard
P.cumt.
P.Pair
P.Point
p.sq.mtr
P/sq.Mt.
per cm height per letter
per cm height per letter
per cubic centimeter
Per Km.
per letter
Per mtr
per pouch
per test
per tonne
per tonne capacity
per.mtr
Point
quintal
Roll_UD
SHEET
Sq.mtr
Tonne
1. Legrand ( Arteor) 2. Havells – ( Murana) 3. M.K. India ( Orna) ) 4. Schneider ( Zencelo, Neo, Ulti)
1. Dauphin – Size 2 MM thick for concealed wiring – ISI Mark /20mm/25mm size Heavy Duty 2. Plaza - ------------do-------------- 3. BEC Plast - ------------do--------------
1. Havells 2. Polycab 3. Universal 4. RR Kable 5. Gloster
1. Havells 2. Polycab 3. Legrand 4. Gloster
1. ABB 2. L & T (MCB & MCCB) 3. Schneider 4. Legrand 5. Havells
1. ABB 2. L & T 3. Schneider 4. Legrand
1. ABB 2. Schneider 3. Legrand 4. Havells
1. Havells 4. Gloster 2. Polycab 3. RR Kable
USHA- Fontana one Antique Brass/Gold Crompton- Titans/Nebula/Jupiter/Kannon Electroplated Havells – Momenta/Futuro/Dew/Cedar/Avion
1. USHA- Maxx Air 2. Crompton - HighSpeed Torpedo 3. Havells - Platina
1 CROMPTON 2. USHA 3. Havells
1. Philips 2. Crompton 3. Wipro
1. Otis 2. Kone 3. Schindler 4. TKE
1.O-General 2. Toshiba 3. Mitsubishi 4. Bluestar 5. Daikin
Edge-Tech/VTS/Citizen
1. Mandav 2. kwality tubes 3. Hario steel 4. Rajco metal
1.Aeroflex 2. Armacell 3. k-flex 4. Thermaflex
1. Jindal 2. Tata 3. SAIL
1. ABB 2. Schinder 3. Siemens
1. Honeywell 2. Pelco 3. Axis 4. Mobotix
1. Honeywell-Essar 2. Seimens-Cerebrus 3. Seimens-Fire finder
RR Cabble/ Polycab/ Finolex
1. Kirlosker 2. Texmo 3. CRI 4. Cromptongreaves 5. KSB
1. Samsung 2. Sony 3. Philips 4. LG
D-link/TP-link/HP
D-link/Mas/Net-Gear
TP-Link/D-link/H.P.
D-link/Molex
D-link/HP/Molex
HP /D-link/HP/Net-gear
D-link/Molex
D-link/Molex/Net Gear
D-link/Molex/Net Gear
D-link/Molex/Net Gear/Digisol
Siemens /NEC / Panasonic/ Cisco /Karel
1. Legrand ( Arteor) 2. Havells – ( Murana) 3. M.K. India ( Orna) ) 4. Schneider ( Zencelo, Neo, Ulti)
1. Dauphin – Size 2 MM thick for concealed wiring – ISI Mark /20mm/25mm size Heavy Duty 2. Plaza - ------------do-------------- 3. BEC Plast - ------------do--------------
1. Havells 2. Polycab 3. Universal 4. RR Kable 5. Gloster
1. Havells 2. Polycab 3. Legrand 4. Gloster
1. ABB 2. L & T (MCB & MCCB) 3. Schneider 4. Legrand 5. Havells
1. ABB 2. L & T 3. Schneider 4. Legrand
1. ABB 2. Schneider 3. Legrand 4. Havells
1. Havells 4. Gloster 2. Polycab 3. RR Kable
USHA- Fontana one Antique Brass/Gold Crompton- Titans/Nebula/Jupiter/Kannon Electroplated Havells – Momenta/Futuro/Dew/Cedar/Avion
1. USHA- Maxx Air 2. Crompton - HighSpeed Torpedo 3. Havells - Platina
1 CROMPTON 2. USHA 3. Havells
1. Philips 2. Crompton 3. Wipro
1. Otis 2. Kone 3. Schindler 4. TKE
1.O-General 2. Toshiba 3. Mitsubishi 4. Bluestar 5. Daikin
Edge-Tech/VTS/Citizen
1. Mandav 2. kwality tubes 3. Hario steel 4. Rajco metal
1.Aeroflex 2. Armacell 3. k-flex 4. Thermaflex
1. Jindal 2. Tata 3. SAIL
1. ABB 2. Schinder 3. Siemens
1. Honeywell 2. Pelco 3. Axis 4. Mobotix
1. Honeywell-Essar 2. Seimens-Cerebrus 3. Seimens-Fire finder
RR Cabble/ Polycab/ Finolex
1. Kirlosker 2. Texmo 3. CRI 4. Cromptongreaves 5. KSB
1. Samsung 2. Sony 3. Philips 4. LG
D-link/TP-link/HP
D-link/Mas/Net-Gear
TP-Link/D-link/H.P.
D-link/Molex
D-link/HP/Molex
HP /D-link/HP/Net-gear
D-link/Molex
D-link/Molex/Net Gear
D-link/Molex/Net Gear
D-link/Molex/Net Gear/Digisol
Siemens /NEC / Panasonic/ Cisco /Karel
1. Legrand ( Arteor) 2. Havells – ( Murana) 3. M.K. India ( Orna) ) 4. Schneider ( Zencelo, Neo, Ulti)
1. Dauphin – Size 2 MM thick for concealed wiring – ISI Mark /20mm/25mm size Heavy Duty 2. Plaza - ------------do-------------- 3. BEC Plast - ------------do--------------
1. Havells 2. Finolex 3. Polycab 4. Universal 5. RR Kable 6. Gloster
1. Havells 2. Finolex 3. Polycab 4. Legrand 5. Gloster
1. ABB 2. Siemens 3. L & T (MCB & MCCB) 4. Schneider 5. Legrand 6. Havells
1. ABB 2. Siemens 3. L & T 4. Schneider 5. Legrand
1. ABB 2. Siemens 3. L & T 4. Schneider 5. Legrand 6. Havells
1. Havells 4. Standard 2. Polycab 5. Finolex 3. RR Kable 6. Gloster
USHA- Fontana one Antique Brass/Gold Crompton- Titans/Nebula/Jupiter/Kannon Electroplated Havells – Momenta/Futuro/Dew/Cedar/Avion
1. USHA- Maxx Air 2. Crompton - HighSpeed Torpedo 3. Havells - Platina 4. BAJAJ - Frore Neo
1 CROMPTON 2 Bajaj 3 USHA 4. Havells
1. Philips 2. Crompton 3. BAJAJ 4. Wipro
1. Otis 2. Kone 3. Schindler 4. TKE
1. Toshiba 2. Mitsubishi 3. Bluestar 4. Daikin 5. O-General
Edge-Tech/VTS/Citizen
1. Mandav 2. kwality tubes 3. Hario steel 4. Rajco metal
1.Aeroflex 2. Armacell 3. k-flex 4. Thermaflex
1. Jindal 2. Tata 3. SAIL
1. ABB 2. Schinder 3. Siemens
1. Honeywell 2. Pelco 3. Axis 4. Mobotix
1. Honeywell-Essar 2. Seimens-Cerebrus 3. Seimens-Fire finder
RR Cabble/ Polycab/ Finolex
1. Kirlosker 2. Texmo 3. CRI 4. Cromptongreaves 5. KSB
1. Samsung 2. Sony 3. Philips 4. LG
D-link/TP-link/HP
D-link/Mas/Net-Gear
TP-Link/D-link/H.P.
D-link/Molex
D-link/HP/Molex
HP /D-link/HP/Net-gear
D-link/Molex
D-link/Molex/Net Gear
D-link/Molex/Net Gear
D-link/Molex/Net Gear/Digisol
Siemens /NEC / Panasonic/ Cisco /Karel
boq_comp_chart.xls
BOQ Comparative Chart • 0.57 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 1.10 MB
815179402317396192_158612_7802287293814106_134633_Guidelines_to_Bidders.pdf
NIT • 0.13 MB
804035537080290318_191099_FORM B.doc
NIT • 0.17 MB
4578452887613566387_191099_PQ.doc
NIT • 0.28 MB
7167446013457554961_191099_ANNEXURE E.doc
NIT • 0.04 MB
4046004808530136781_191099_191099 Notice Club House.docx
NIT • 0.06 MB
1701285674539816201_191099_NIT.doc
NIT • 0.31 MB
3287657091751203017_191099_BOQ.xlsx
BOQ • 0.12 MB
409857066290789952_191099_LIST OF APPROVED MATERIALS.xlsx
BOQ • 0.02 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .