Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.7 LAccepted-AOC CHOMO JALANDHAR PUNJAB 144103 | JALANDHAR | PUNJAB | 144103 | L1 | Accepted-AOC L1 | |
| 2 | L2₹41.0 L+₹1.1 L (2.63%)Rejected-Finance NEAR RAILWAY CROSSING ADAMPUR DOABA JALANDHAR JALANDHAR PUNJAB 144103 | JALANDHAR | PUNJAB | 144103 | L2 | Rejected-Finance Other than lowest. | |
| 3 | L3₹41.6 L+₹1.6 L (3.98%)Rejected-Finance SHOP NO 5 OPP SHANI MANDIR PROFESSOR COLONY DISTT YAMUNA NAGAR HARYANA 135001 | YAMUNANAGAR | HARYANA | 135001 | L3 | Rejected-Finance Other than lowest. | |
| 4 | L4₹42.1 L+₹2.1 L (5.17%)Rejected-Finance VILL CHOMON ADAMPUR JALANDHAR PUNJAB 144103 UDYAM PB 10 0011450 | JALANDHAR | PUNJAB | 144103 | L4 | Rejected-Finance Other than lowest. | |
| 5 | L5₹44.3 L+₹4.3 L (10.8%)Rejected-Finance 27 19 F F D BLOCK CHATTARPUR EXTN SOUTH WEST DELHI DELHI 110075 | SOUTH WEST DELHI | DELHI | 110075 | L5 | Rejected-Finance Other than lowest. |
Tender Value
₹43.6 L
EMD Value
₹87,200
Closing Date
17 Jun 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer Air Force
Military Engineer services Airforce Stn Adampur 144103
PROVN OF CERTAIN SANCTION WORK IN TECH AREA AT AF STN ADAMPUR
2024_MES_648268_3
GE/AF/ADM-71/2023-24
Open Tender
Civil Works
Item Rate
180 days
Tech Area GE AF Adampur
Refer NIT and Tender Documents
8 documents required · 8 mandatory
₹500
GE AF Adampur
₹87,200
Yes
16 Jul 2024
3 Jun 2024
18 Jun 2024
3 Jun 2024
17 Jun 2024
4 Jun 2024
Amount
BR WORKS
Surface excavation n.exc (not exceeding) 30cm deep and averaging 15cm deep and getting out in SOFT/LOOSE soil complete, all as specified.
Excavation in trenches n. exc 1.5 m wide for foundations, laying cables/ pipes etc. not exceeding 1.5 m deep and getting out in SOFT/LOOSE soil complete, all as specified.
Earth work in excavation by mechanical means (Hydraulic excavator) means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 Sq.m on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5m, complete all as specified.
Returning filling in including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick complete, all as specified.
Removing excavated spoil to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete, all as specified.
Broken bricks hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete, all as specified.
Anti-termite treatment of soil by treating the backfill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of vertical surface (Area of the substructure in contact with backfill to be measured) complete all as specified.
Anti-termite treatment of soil by treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface complete all as specified.
Anti-termite treatment of soil by treating soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area complete all as specified.
PCC type C-2 (1:3:6), using 40 mm graded stone aggregates as in filling & mass concrete, complete all as specified.
PCC type D-2 (1:4:8), using 40 mm graded stone aggregates as in filling & mass concrete, complete all as specified.
PCC type B-0 (1:2:4), using 12.5 mm graded stone aggregates as in in roof kerbs or mud stops, rounded or chamfered on edges, using water proofing compound, complete all as specified.
Reinforced cement concrete, M-25 (Design Mix), as in in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified.
Reinforced cement concrete, M-25 (Design Mix), as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified.
Reinforced cement concrete, M-25 (Design Mix), as in chajjas, and the like complete all as specified.
Reinforced cement concrete, M-25 (Design Mix), as in beams, cantilevers, bressumers, lintels over 1.5 metre clear span and the like complete all as specified.
Reinforced cement concrete, M-25 (Design Mix), as in columns, pillars, piers, posts and struts complete all as specified.
Supply only water proofing compound, ISI marked, complete all as specified.
Brick work using bricks as specified in PS-II clause 5.1, straight or curved on plan exceeding 6.00 metre mean radius built in cement mortar (1:6), complete all as specified.
Use & waste of formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter with rough finished surfaces of concrete, complete all as specified.
Use & waste of formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200 mm thick (Horizontal or sloping) with fair finished surfaces of concrete, complete all as specified.
Use & waste of formwork to sides of pillars, posts, struts, piers, columns and stanchions with rough finished surfaces of concrete, complete all as specified.
Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide complete, all as specified.
Factory made uPVC white colour casement door with 3D hinges made of (big series) frame 67 x 64 mm & sash 67 x 110 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of door upto 2.00 sqm) comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, zinc alloy (white powder coated) 3D hinges and one handle on each side of panels along with zinc plated mild steel multi point locking having transmission gear, cylinder with keeps and one side key, G.I. fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws,etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality complete all as specified. NOTE: The unit rate quoted by contractor excludes cost of glass and includes all other connected accessories.
Solid PVC wall lining consisting of 5 mm thick plain colour PVC sheet inclusive of solvent cement and fixing on PVC frame complete all as specified.
5 mm thick PVC sheet fillet of width 35 mm for wall paneling inclusive of fixing on to wall to make PVC frame, complete all as specified.
Stainless steel conduit 20 mm bore, cut to size and erected in position as curtain rod on backets, with & including SS decorative finials & brackets, PVC rings @ 10 nos. per metre, fixed to walls with PVC rawl plugs & SS screws, complete.
Double leg aluminium anodised door stopper with rubber foot, ISI marked and fixed to bottom rail of doors with steel screws, complete.
Aluminium (Die cast) door closer hydraulically regulated designation No. 3 aluminium body universal type suitable for door shutters of 851 to 1000 mm in width and weight between 61 to 80 kg, ISI marked, complete all as specified
Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified.
Mild steel TMT bars 6 mm to 8 mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified.
Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/ intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre, complete all as specified.
Seamless calcium silicate ceiling made out of 8 mm thick1800 x 1200 mm size board of siliceous and calcareous material reinforced with cellulose fibre fixed to the ceiling section with 25 mm long self drilling and tapping screws having phillips head with under head cutter at 200 mm centre to centre, including finshing the joint of face board with specially formulated jointing compound and 48 mm wide fibre tape to provide seam less finish, complete all as specified.
Water Proofing Treatment to RCC roofs comprising of : -
Rendering 15 mm thick (Average thickness) rendering on roof surface including flashings and junction of parapets etc., finished even and fair in cement mortar (1:4), using water proofing compound as recommended by manufacturers after brushing cement slurry @ 1.20 kg/Sq. m, complete all as specified. NOTE: Supply only WPC will be measured & paid for separately under respective item of BoQ.
APP based polymeric membrane laid on primed roofs & flashing by forced application using Butane torch and sealing all joints on primed surface by applying hot blown industrial grade bitumen @ 85/25 @ 1.20 kg/Sq.m over a coat of bitumenous primer @ 0.40 litre per square metre over clean RCC/plastered roof surfaces & flashings complete, all as specified.
Making benching with PCC (1:2:4) type B-0 (using water proofing compound) along side walls adjoining to roofs, in CONCAVE SHAPE, complete all as specified. NOTES: (i)WPC will be measured and paid for separately under respective item of BoQ. (ii) For Performance Guarantee of Water Proofing Treatment refer PS clause 11.5.
25 mm thick, cement concrete type B-0, 1:2:4 using 12.5 mm graded stone aggregate, finished even & rough, as in sub floors, complete all as specified.
75 mm thick, cement concrete type C-1, 1:3:6 using 20 mm graded stone aggregate, finished even & smooth without using extra cement, as in plinth protection, and joints shall be sealed with joint sealing comound grade 'A' complete all as specified.
100 mm thick, cement concrete type D-2, 1:4:8 using 40 mm graded stone aggregate, finished even & rough, as in floors, complete all as specified.
Coloured vitrified (double charged) ceramic tiles 9-10mm thick (square/ rectangular) area of each tile exc. 0.42 Sq.m but n. exc. 1 Sq.m, laid in floors etc, set and jointed in neat cement slurry and pointed with grout of matching shade of tiles, laid over and including 15 mm thick bedding layer in cement mortar (1:4), complete all as specified.
Coloured vitrified (double charged) ceramic tiles 9-10mm thick (square/ rectangular) area of each tile exc. 0.42 Sq.m but n. exc. 1 Sq.m, on vertical surfaces as in skirting, dado etc. set and jointed in neat cement slurry and pointed with grout of matching shade of tiles, laid over and including 10 mm thick bedding layer in cement mortar (1:4), complete all as specified.
80 mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of shape approved by GE, made by table vibratory method using PU mould, laid in required pattern over and including 50mm thick compacted bed of coarse sand, compacting through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand; complete.
Rendering 5 mm thick on fair faces of concrete surfaces, finished even and smooth on ceiling for area not covered with false ceiling in cement mortar (1:3), complete all as specified.
Rendering 15 mm thick on fair faces of brick work or concrete surfaces, finished even and fair on walls in cement mortar (1:6) complete all as specified.
Rendering 15 mm thick on fair faces of brick work or concrete surfaces, finished even and fair on walls in cement mortar (1:4), mixed with water proofing compound as per manufacturers instructions, complete all as specified. NOTE: WPC will be measured and paid for separately under respective item of BoQ.
Prepration of new plasterd wall & ceiling surfaces of any description complete all as specified and applying the following: - (a) Applying wall care putty, in two coats & smoothening the surfaces as specified. (preparatory to paint as directed). (b) Two coats of interior acrylic distemper/oil bound distemper over and including a coat of interior primer.
Prepration of new plasterd wall surfaces of any description complete all as specified and applying the following: - a) Applying wall care putty, in two coats & smoothening the surfaces as specified. (preparatory to paint as directed).complete all as specified. (b) Two coats of exterior acrylic emulson over and including a coat of water based exterior primer in disruptive/camouflaging pattern of four shades for height upto 7.5 metre complete all as specified. NOTE:- (i) RGB value of four shades of disruptive/camouflaging pattern shall be all as shown on Drg No. GE/SK-1/19 sheet 1/2 & 2/2. (ii) The rate quoted by the contractor shall included for scaffolding and necessary formwork.
EM WORKS
Point wiring with multi-stranded copper conductor, single core, PVC insulated and unsheathed FRLSH cable, including PVC insulated unsheathed stranded copper conductor single core FRLSH cable as earth continuity conductor to common earth and connected to earth dolly, with and including GI terminal boxes with base frame & cover plate suitable (for fixing modular switch/sockets) comprising the following: -
One light point controlled by one switch or one fan point controlled by one switch & fan regulator etc. or for bell/buzzer with 1.5 Sq. mm (nominal area) cable & 1.5 Sq. mm (nominal area) cable as earth continuity conductor, in and including rigid non metallic PVC medium duty concealed conduit all as specified.
One Socket outlet, 6 Amp, on the same board, with 1.5 Sq. mm (nominal area) cable & 1.5 Sq. mm (nominal area) cable as earth continuity conductor, all as specified.
One Socket outlet, 6 Amp, independent, with 1.5 Sq. mm (nominal area) cable & 1.5 Sq. mm (nominal area) cable as earth continuity conductor, in and including rigid non metallic PVC medium duty concealed conduit all as specified.
One socket outlet, 6/16 Amp, independent, with 2.5 Sq. mm (nominal area) cable & 2.5 Sq. mm (nominal area) cable as earth continuity conductor, in and including rigid non metallic PVC medium duty concealed conduit all as specified.
One socket outlet three pin, 6/16 Amp, independent, with 4 Sq. mm (nominal area) cable & 4 Sq. mm (nominal area) cable as earth continuity conductor, in and including rigid non metallic PVC medium duty concealed conduit all as specified.
NOTES FOR SERIAL ITEM NO 50: (a) Switch(es) & socket(s) shall be measured & paid for separately under respective item of Schedule 'A'. (b) GI boxes shall be fixed flush to walls in position with cement mortar (1:4) complete all as directed. (c) Conduit shall be laid on surface in case of RCC ceiling surfaces.
Switch modular type single pole one way, 6 Amp, complete all as specified.
Bell push switch modular type single pole one way, 6 Amp, complete all as specified.
Switch modular type single pole one way, 16 Amp,complete all as specified.
Socket outlet modular type multipurpose having provision for 2&3 pin, 6 Amp, complete all as specified.
Socket outlet modular type multipurpose having provision for two-in-one 3 pin 6 Amp & 3 pin 16 Amp, complete all as specified.
Fan regulator modular type (electronic) suitable for 48”/56” sweep fan, step type, two module, complete all as specified.
Ceiling rose, surface bakelite, 65 x 50mm, three terminals complete, all as specified.
Lamp (angle) holder, insulated body, cord grip pattern, complete, all as specified.
Electric buzzer AC 230 volt, single pole, Ding Dong type complete, all as specified.
MAKE FOR SERIAL ITEM 51 TO 60: HAVELLS, LEGRAND or equivalent compatible make mentioned in Appendix 'B'.
Sub main wiring (with approved colour coding as per IS) with single core FRLS PVC insulated flexible stranded copper conductor 1.1 KV grade (main cable: number of runs as indicated below along with single core FRLS PVC insulated flexible stranded copper conductor 1.1 KV grade for earthing in conduits, complete all as specified for the following: -
2 runs of 6 Sq. mm main cable + 1 run of 6 Sq. mm earth cable NOTES: - (i) Conduit & conduit accessories shall be measured & paid for separately. (ii) For payment purposes, total runs of main cable (each run of one running metre) as mentioned above and one run (one running metre) of earth cable shall be considered together as "1 RUNNING METRE"
Rigid non metallic, PVC concealed conduit not less than 20 mm bore, medium grade, ISI marked, inclusive of all fitings (such as junction boxes, bends, elbows, tees, reducers, bell mouth tube ends) and all fixing acessories such as couplers, lock nuts, saddles, pipe hook etc. for sub main wiring and the like complete all as specified.
Sheet metal enclosure for DB for fixing MCB’s, isolators etc., having IP-43 protection, suitable for surface and flush mounting, complete all as specified comprising the following: -
SPN, 12 way with 200 Amp rated bus bar, 240 V, double door type.
VTPN, 4 way with 200 Amp rated bus bar, 415 V, double door type having housing and including MCCB 4 pole 63 Amp, 16kA.
MCB suitable for 240 volt AC supply, SP with over load and short circuit protection and rupturing capacity not less than 10 kA, 'C' curve type of rating 6 to 32 Amp complete all as specified.
MCB suitable for 240 volt AC supply, SPN with over load and short circuit protection and rupturing capacity not less than 10 kA, 'C' curve type of rating 6-32 Amp complete all as specified.
Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amp, 240 volt, breaking capacity not less than 10 kA, complete all as specified.
Blanking plate to cover unused space in DB's complete all as specified..
Environment friendly, modern design, energy saving surface mounted, decorative 10 W bulk head LED luminaire with premium quality diffuser fo glarefree light, 6000K, complete. MAKE: Havells Cat No. HEXAFT10WLED857SSYMBOPC or equivalent in makes mentioned in Appendix 'B' here-in-after.
Surface mounted environment friendly with eye soft technology & glarefree diffuser LED 20 W lighting , 6500K, lumen output should not be less than 90 lumens per watt complete. MAKE: Havells Cat No. ENDURALINEARNEOBS20WLED865SPCWH or equivalent in makes mentioned in Appendix 'B' here-in-after.
Recess mounted bottom opening LED 36W cool day light luminaire (2x2) CRCA powder coated housing, IP- 54 protection, suitable for grid ceiling lumen output should not be less than 90 lumens per watt complete. MAKE: Havells Cat No. DROPDOWNFLAT2X2PLR36WLED857 or equivalent in makes mentioned in Appendix 'B' here-in-after.
LED street light 35 watt outdoor type pressure die cast aluminium housing, heat resistant toughtened glass with frame and tamp with minimum efficiency 110 LM/W and connected including suitable size 3 core copper cable for connection of fitting & IP 66 protection complete. MAKE: ENDURASUNDOWNSL35WLED765PASYBOPC or equivalent make mentioned in Appendix 'B'.
Ceiling fan 1200 mm sweep, 230 V with blades & down rod, minimum air delivery 210 CFM with service value 6.00 BEE, five star rated, brushless direct current motor (BLDC) and connecting up from ceiling rose or connector to fan, complete all as specified. MAKE: Havells Cat No. FHCEO5SWHT48 or equivalent in makes mentioned in Appendix 'B' here-in-after.
Boring holes 80 to 100 mm bore pipe line under roads, paths, hardstanding, pavements, taxy track of any desciption by trenchless technology using ultrasound technique or by manual boring method of hole technique for passing pipe lines complete.
Clean dry sand ( locally available) as cushioning for under ground cable 230 mm thick (one layer of 80 mm thickness before laying the cable and other layer of 150 mm thickness after laying the cable) complete all as specified. NOTE:- Punned down thickness (over all 180 mm) shall be considered for measurement and payment.
Bricks as specified in PS clause 5.1, laid flat and dry in trenches over the cable for protection as length perpendicular to the direction of cable adjacent to each other complete, all as specified.
Steel tubes 50 mm bore ‘light grade’, galvanized with all fittings and fixed to poles/ walls/ under floors/ under road etc complete all as speciifed.
Supply, laying, jointing & testing of LT XLPE insulated cable screened, bedded, galvanised steel strip or wire armourd cable (heavy duty) 1100 volt grade with aluminium conductor conforming to IS-7098 (Part-I -1988) laid in trenches/ ducts/ through pipes/ in floors / under roads/ hard standing /along poles and testing complete all as specified of sectional area 50 Sq. mm, 2 core.
Cable joining kit (straight through cold shrinkable) for 1100 V (Earthed) grade cable complete with jointing material and accessories suitable for XPLE armoured aluminium conductor 50 Sq. mm, 3.5 to 4 core cable complete all as specified.
Earthing complete with galvanised iron earth plate electrode of size 600 x 600 x 6 mm buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including GI wire 4 mm dia (upto the cross arms) by means of GI bolts/nuts/washers, protected by 15 mm bore GI light grade pipe. Earth plate shall be surrounded by alternate layer of charcoal or coke and common salt 15 cm thick all around bottom and top. 20 mm bore GI light grade pipe for watering and including funnel, wire mesh, factory made PCC earthing pit chamber & cover including necessary excavation & earth work, all as specified & shown in electrical plate No. 3 of MES Schedule Part – I NOTE:- (i) Factory made PCC pit chamber shall be provided at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner. (ii) The unit rate includes earthing lead & protection pipe upto 7.5 metre from top of earth plate.
Earthing complete with galvanised iron earth plate electrode of size 600 x 600 x 6 mm buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including GI strip 32x6 mm (upto the cross arms) by means of GI bolts/nuts/washers, protected by 40 mm bore GI medium grade pipe. Earth plate shall be surrounded by alternate layer of charcoal or coke and common salt 15 cm thick all around bottom and top. 20 mm bore GI light grade pipe for watering and including funnel, wire mesh, factory made PCC earthing pit chamber & cover including necessary excavation & earth work, all as specified & shown in electrical plate No. 5 of MES Schedule Part – I NOTE:- (i) Factory made PCC pit chamber shall be provided at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner. (ii) The unit rate includes earthing lead & protection pipe upto 7.5 metre from top of earth plate.
LT panel board, outdoor type, CPRI approved all as specified in particular specifications of contract clause 19.16 including installation, commissioning & testing,comprising the following components/acessories: - (a) Multifunctional meter electronic with suitable CTs, showing Amp, Volt, PF, HZ and other parameter rating Amp upto 300A & volt upto 500V -01 Set. (b) LED indicating lamp for R,Yand B phases-01set (set of three) (c) Internal power & control wiring with suitable size PVC insulated multistranded copper wire (d) Copper bus bar of 200 Amp capacity, 4 strip mounted on porcelain insulators. (e) MCCB 4 pole, 415 volt, 200 Amp, 25 kA -01 No. (Incomming) (f) MCCB 4 pole, 415 volt, 100 Amp, 16 kA - 02 Nos. (Outgoing).
M/S GURBACHAN SINGH
JS CONSTRUCTION COMPANY
M/s Sahib and Company
KULWANT SINGH
MALHOTRA AND ASSOCIATES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .