Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.3 LAccepted-AOC RZ 50D GALI NO 13 VASHISHT PARK PANKHA ROAD NEW DELHI 110046 | NEW DELHI | DELHI | 110046 | L1 | Accepted-AOC AOC | |
| 2 | L2₹23.0 L+₹5.3 L (30.0%)Rejected-AOC | L2 | Rejected-AOC Rejected | |
| 3 | L3₹24.3 L+₹6.6 L (37.4%)Rejected-AOC | L3 | Rejected-AOC Rejected |
Tender Value
Refer Docs
EMD Value
₹94,000
Closing Date
15 Jun 2023, 9:00 amClosed
GE (AF) Gurgaon No 1
GE (AF) Gurgaon No1 Near Atul Kataria Chowk Gurgaon
CA NO. GE AF NO.1/GUR-22/2023-24 REPAIR AND MAINTENANCE OF 250KLPD AND 85KLPD SEWAGE TREATMENT PLANT AND AUXILARY E/M ITEMS AT AF STN GURGAON UNDER GE (AF) GURGAON NO.1.
2023_MES_594961_1
GE AF No 1/GUR-22/2023-24
Open Tender
Miscellaneous Works
Item Rate
270 days
GE (AF) Gurgaon No 1
All as per NIT
10 documents required · 10 mandatory
₹500
GE (AF) Gurgaon No 1
₹94,000
Yes
30 Jun 2023
12 May 2023
17 Jun 2023
12 May 2023
15 Jun 2023
27 May 2023
Amount
Supply only sodium hypochlorite in factory sealed HDPE container (40 to 50 Ltrs each) having, chlorine concentration level not less than 65% complete all as specified and as directed. Make: -Decibac / Shree Rayalseema or equivalent as approved in MES in E-in-C or in any command.
Testing of Sewage Treated water as per relevant IS of STP , submission of detailed test report before and after treatment of water. Testing should be done from Govt approved laboratory Test report indicates the following parameters :- (a) Carrying out minimum essential testing of sewage water as per revlevant IS mandatory for chemical, odour, PH Value, TSS, BOD,COD total nitrogen, sulphate, oil and grease ammonical Nitrogen (NH3-N) and Bacteriological total collifrom organisms and other charaterstics as per relevant IS of sewage water. Note: Testing to be done in 1st week of every month.
Cleaning of Oil & Grease Strap tank, Equilization tank, CCT Tank, sludge tank & Treated water tank of 250 KLPD Plant complete all as specified and as directed by Engr-in-charge. Note :- Cleaning shall be carried out by the following methods (i) Removing all the existing water from the tank through tankers (ii) Cleaning inner surface of tank by scraping with steel wire brush and removing mud & sludge collected inside the tanks manually at a distance not exceeding 50 Mtrs. (iiI) Washing with clean water & bleaching powder mixture complete tank internally and removal of left out sludge. (iii) Labour and T&P required for removal of settled down sewage sludge/mud inside the sewage tank for scooping out from inside and below the septic/staining sewage water inside the well and lifting the same and deposited on top and near by the sewage tank where directed and further to removal the same where approved by the PCB (iv) All Safety measures to be taken by the contractor for doing the cleaning.
Cleaning of Oil & Grease Strap tank, Equilization tank, CCT Tank, sludge tank & Treated water tank of 85 KLPD Plant complete all as specified and as directed by Engr-in-charge Note :- Cleaning shall be carried out by the following methods (i) Removing all the existing water from the tank through tankers (ii) Cleaning inner surface of tank by scraping with steel wire brush and removing mud & sludge collected inside the tanks manually at a distance not exceeding 50 Mtrs. (iiI) Washing with clean water & bleaching powder mixture complete tank internally and removal of left out sludge. (iii) Labour and T&P required for removal of settled down sewage sludge/mud inside the sewage tank for scooping out from inside and below the septic/staining sewage water inside the well and lifting the same and deposited on top and near by the sewage tank where directed and further to removal the same where approved by the PCB (iv) All Safety measures to be taken by the contractor for doing the cleaning.
Supply , laying and fixing in replacement of HDPE pipe of 110mm dia of PE -63 material Black colour having 6kgf/cm2 pressure rating alongwith joint i.e. elbow,Tee,union.coupler, end cap etc with Compressor push fitting as specified and directed by Engr-in-Charge. Make: Supreme/diplast/kisan /SFMC or equivalent from the make specified . Note: Compressor joint and all other joint included in this quoted rate.
Supply , laying and fixing in replacement of HDPE pipe of 90mm dia of PE -63 material Black colour having 6kgf/cm2 pressure rating alongwith joint i.e. elbow,Tee,union.coupler, end cap etc with compressor push fitting as specified and directed by Engr-in-Charge. Make: Supreme/diplast/kisan /SFMC or equivalent from the make specified . Note: Compressor joint and all other joint included in this quoted rate.
Supply , laying and fixing in replacement of HDPE pipe of 50mm dia of PE -63 material Black colour having 6kgf/cm2 pressure rating alongwith joint i.e. elbow,Tee,union.coupler, end cap etc with compressor push fitting as specified and directed by Engr-in-Charge. Make: Supreme/diplast/kisan /SFMC or equivalent from the make specified . Note: Compressor joint and all other joint included in this quoted rate.
Excavation in trenches not exceeding 1.5M wide and not exceeding 1.5M in depth for foundation etc or for shafts, wells, cesspits, manholes, pier holes etc not exc 10 Sqm on plan and not exc 1.5M in depth and getting only out in hard soil/standing complete all as specified and directed
Returning, filling in trenches including spreadin, levelling watering and well ramming in layers not exceeding 25 cms thick in each layer of oil complete all as specified and directed
Removing surplus excavated material to a distance exc 50 Mtr and deposting where directed at l level not exceeding 1.5 Mtr above the starting point all as specified and directed by Engr - in Charge
M&L for sand cushioning in trenches for protection of LT under ground cable including punning and consolidation complete as sepecified and directed by Engr-in-Charge.
Supply and laying well burnt sub class ‘B’ bricks, locally available in trenches for protection of underground cable complete as sepecified and directed by Engr-in-Charge.
S&F Compressor push Coupler joint of Dia 110mm HDPE pipe all as specified and directed by Engr - in Charge Make: Supreme/diplast/kisan
S&F Compressor push Coupler joint of Dia 90mm HDPE pipe all as specified and directed by Engr - in Charge Make: Supreme/diplast/kisan
S&F Compressor push Coupler joint of Dia 50mm HDPE pipe all as specified and directed by Engr - in Charge. Make: Supreme/diplast/kisan
M&L for filling of tube media including removing the water and cleaning Tube Settler Tank complete all as specified and directed by Engr-in-Charge.
M&L for filling of Fab MBBR media including removing the water and cleaning complet from the MBBR tank 1 & 2 complete all as specified and directed by Engr-in-Charge. Note: Water to be removed through filling of water tankers and thereafter cleaning to be done all this rate is included in quoted rate.
S&F of Dosing Pump IMP 64 Diaphragm Water Pump (0.5 hp) , Electrical 230 V AC, 50 Hz., Splash-proof enclosure, Dosing rate @ 4 Kg/Cm² & 10.0 Lph, Built in air release valve (ARV) , IP 65 certified, Suction/Discharge tubing 4/6 mm complete all as specified and directed by Engr-in-Charge. Make :- Edose or equivalent as approved.
M&L for filling of Sand media including removing the water and cleaning complete from Sand Filter complete all as specified and directed by Engr-in-Charge.
M&L for filling of Carbon media including removing the water and cleaning complete from Carbon Filter complete all as specified and directed by Engr-in-Charge.
M&L for filling of EM Bio Culture , Microorganism Solution, standard grade, for sewage treatment plant all as specified and directed by Engr-in-Charge. Make:- Futuretech water solutions /Ecomaster / MM Aqua or equivalent as approved in MES .
M&L for filling of Bacteria solvent all as specified and directed by Engr-in-Charge
M&L for filling of urea all as specified and directed by Engr-in-Charge.
M&L for filling of DAB all as specified and directed by Engr-in-Charge.
M&L for fixing of butterfly valve 2" in Sludge drain tank along with its fixture and fitting complete all as specified and directed by Engr-in-charge.
M&L for pressure gauge (4") 7Kg alongwith its fitting and fixture all as specified and directed by Engr-in-Charge.
M&L CVD diffuser in MBBR Tank complete all as specified and directed by Engr-in-Charge
M&L in replacement of GI Pipe 50mm dia alongwith Tee & Elbow complete all as specified and directed by Engr-in-charge
S&F in replacement of Air Release Valve of 50mm Dia alongwith Saddle and UPVC pipe all as specified and directed by Engr-in-charge
S&F GI Butterfly valve 4" size alongwith all its fixtures and fittings all as specified and directed by Engr-in-charge
S&F GI Butterfly valve 3" size alongwith all its fixtures and fittings all as specified and directed by Engr-in-charge
M& L for Repair & testing of parts of starter panels complete all as specified and as directed by Engr-in-charge. (Note;- The rate also includes change of Wiring of any size in the panel. Parts required are seperately measured in the schedule)
S&F in replacement Voltage monitor relay (3 phase ) AC : 110/ 415Volt Setting 75 -100/300 - 400 V, complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement Over current relay definite time Non directional ,definite time & current adjustable setting 0.5 -5A 1-10A /0.1-1A time 0-10 sec, complete all as specified and directed by Engineer-in-Charge.
Supply & Fixing only Electronic Phase sequencing relay all as specified and as directed by Engr-in-Charge . Make:Universal or equivalent out of make mentioned list of make.
S & F in replacement of Contractor MNX 25, 240V 50/60Hz upto 500V,50/80Hz 3 Pole all as specified and as directed by Engr-in-Charge.
S & F in replacement of Contractor MNX 18, 240V 50/60Hz upto 500V,50/80Hz 3 Pole all as specified and as directed by Engr-in-Charge.
S & F in replacement of Contractor MNX A2, 240V 50/60Hz upto 500V,50/80Hz 3 Pole all as specified and as directed by Engr-in-Charge .
S & F in replacement of Contractor MNX 9, 240V 50/60Hz upto 500V,50/80Hz 3 Pole all as specified and as directed by Engr-in-Charge .
S& F in replacement of MCB 63Amp 4Pole,415V ,16KA as specified and directed by Engr-in-charge.
S& F in replacement of MCCB 100Amp 4Pole,415V ,16KA as specified and directed by Engr-in-charge
M&L complete for drilling hole under hard standing /road in different location as per site requirement (between 03 mtr to 12mtr maximum) for laying of HDPE pipe by means of bookle and without disturbing the top surface and making good the disturbed surface if any complete all as specified.
S&F of Float Valve 80mm dia size all as specified and directed by Engr-in-Charge
M&L for replacement of perforated cable tray 16SWG of width 150mm(6") complete all as specified and directed by Engr-in-charge
M&L Preperation of old painted Steel surface of any description not otherwise described over 10 cm width or girth and applying two coat of synthetic enamel paint over one coat of Red oxide primer all as specified and directed by Engineer -in-charge
S&F Valve box all as specified and directed by Engr-in-charge
S&F ball Valve of 50mm dia all as specified and directed by Engr-in-charge
Supply installation, testing, commissioning of mechanical flow meter 100mm CI flanged type of reputed make conforming to ISO: 4064/1 specification alongwith making necessary arrangement to fix in existing pipeline complete in all respect as per directed and specified by Engr-in-charge. Make : Kranti/ABB Ltd/Flui Tec Instruments & Construction
M&L for cutting and taking out unserviceable copper wire windings from the rotor grooves of the SUBMERSIBLE SEWAGE NON CLOG PUMP, 7.5HP, cleaning the grooves/ rotor with chemical reagent, re – winding the same with super enamelled PVC insulated copper wire of suitable gauge (Approx Kgs -4.5Kg) including teflon tape insulating paper jointing material and other accessories etc complete all as specified and directed by Engineer-in-Charge. Note : Rate included taking out & refixing of pump & motor from the sump.
M&L for cutting and taking out unserviceable copper wire windings from the rotor grooves of the SUBMERSIBLE SEWAGE NON CLOG PUMP, 12.5hp, cleaning the grooves/ rotor with chemical reagent, re – winding the same with super enamelled PVC insulated copper wire of suitable gauge (Approx Kgs -5Kg) including teflon tape insulating paper jointing material and other accessories etc complete all as specified and directed by Engineer-in-Charge. Note : Rate included taking out & refixing of pump & motor from the sump.
M&L for cutting and taking out unserviceable copper wire windings from the rotor grooves of the 25 HP submersible motor, cleaning the grooves/ rotor with chemical reagent, re – winding the same with super enamelled PVC insulated copper wire of suitable gauge (Approx Kgs - 7.5) including teflon tape insulating paper jointing material and other accessories etc complete all as specified and directed by Engineer-in-Charge. Note : Rate included taking out & refixing of pump & motor from the sump.
M&L for cutting and taking out unserviceable copper wire windings from the rotor grooves of the 2.5 HP submersible motor, cleaning the grooves/ rotor with chemical reagent, re – winding the same with super enamelled PVC insulated copper wire of suitable gauge (Approx Kgs - 9.5) including teflon tape insulating paper jointing material and other accessories etc complete all as specified and directed by Engineer-in-Charge. Note : Rate included taking out & refixing of pump & motor from the sump.
Monthly Technician charges for checking up working of STP Plant or whenever required of parameter i.e. BOD, COD, Sludge, PH value complete all as directed by Engineer-in-charge.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 70 sq mm 3½ core all as specified and directed
M& L in replacement of standpost to water sprinkler plastic 15-18mtr range, Type Pop Up 25 mm dia all as specified and directed by Engr-in-charge
S&F in replacement of Air Release Valve of 90mm Dia alongwith Saddle and UPVC pipe all as specified and directed by Engr-in-charge
Note:- (a) The amount of Rs 39,130/- against Schedule of Credit on Page No 110 shall be deducted from the total amount quoted against Sch 'A' while deriving the Contract Sum for Acceptance.
NAVYUG VYAPARI
GARG TRADERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .