Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Accepted-Technical CHIRANG PIN 783380 | BONGAIGAON | ASSAM | 783380 | Accepted-Technical Admitted |
| 2 | Accepted-Technical | Accepted-Technical Admitted |
| 3 | Accepted-Technical | Accepted-Technical Admitted |
| 4 | Accepted-Technical AMALGANJ PT 7 RANGAMATI GAURIPUR DHUBRI | Accepted-Technical Admitted |
Tender Value
₹19.7 L
EMD Value
₹39,414
Closing Date
19 Jan 2026, 2:00 pmClosed
MD, NHM, Assam
O/O MD, NHM, Assam
Construction of PHC Building at various places of Assam under NRHM at Gotipara in Dhubri District
2025_NHM_49795_3
NHM/ECF/701910
Open Tender
Civil Works - Building
Item Rate
150 days
Dhubri
Please refer Tender documents.
5 documents required · 5 mandatory
₹400
₹39,414
Yes
5 Mar 2026
31 Dec 2025
20 Jan 2026
31 Dec 2025
19 Jan 2026
31 Dec 2025
Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :4.1.5 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal sizederived from natural sources)
Supplying and filling in plinth with sand under floors, including watering,ramming, consolidating and dressing complete.
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size de rived from natural sources)
5.2 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns,pillars, piers, abutments, posts and struts etc. above plinth level up tofloor five level, excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
5.9 Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete
Suspended floors, roofs, landings, balconies and access platform
Lintels, beams, plinth beams, girders, bressumers and cantilevers
Columns, Pillars, Piers, Abutments, Posts and Struts
Dry brick pitching half brick thick in drains including supply of bricks and preparing the surface complete :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Brick work with common burnt clay modular bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand)
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in Superstructure above plinth level up to floor V level.Cement mortar 1:4 (1 cement :4 coarse sand)
Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 40 mm thick with 20 mm nominal size stone aggregate
Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement.12 mm cement plaster
15 mm cement plaster on the rough side of single or half brick wall of mix :1:4 (1 cement: 4 fine sand)
Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete upto plinth level. Mild steel and Medium Tensile steel bars
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding andbolted with special shaped washers etc. complete Electric resistance or induction butt welded tubes
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all completeFixed to openings /wooden frames with rawl plugs screws etc.
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two or more coats) over and including water thinnable priming coat with cement primer
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : Water thinnable cement primer
Finishing walls with water proofing cement paint of required shade : New work (Two or more coats applied @ 3.84 kg/10 sqm)
Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications :Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/10 sqm of approved brand and manufacture
Applying priming coat:With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/steel works
Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture
Boring with 100 mm diameter casing pipe for hand pump / tubewell,in all soils except ordinary hard rocks requiring blasting, including removing the casing pipe after the hand pump / tube well is lowered and tested : Beyond 12 m and up to 18 m depth
Providing and placing in position filters of 40 mm diameter G.I. pipe with brass strainer of approved quality.
Providing and fixing to filter and lowering to proper levels 40 mm G.I. pipe for tube well including cleaning and priming the tube well.
Providing and placing in position hand pump of approved quality for 40 mm diameter G.I. pipe complete with all accessories
18.46 Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) :65 mm nominal bore
Providing and fixing rectangular high density polyethylene water storage loft tank with cover, conforming to ISI : 12701, colour of opaque white or as approved by Engineer-in-charge. The rate includesmaking necessary holes for inlet, outlet & over flow pipes. The base support i/c fittings & fixtures for tank shall be paid separately
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 15mm nominal bore
18.3 Providing and fixing Polyethelene-Aluminium- Polyethelene PE-ALPE Composite Pressure Pipes conforming to IS - 15450, U.V. stabilized with carbon black having thermal stability for hot & cold water supply, capable to withstand temperature up to 80°C, includingall special fittings of composite material (engineering plastic blend and brass inserts wherever required) e.g. elbows, tees, reducers,couplers & connectors etc., with trenching, refilling and testing of joints complete as per direction of the engineer in charge.External work 4050 (50 mm OD ) pipe
18.7 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall 40 mm nominal dia Pipes
25 mm nominal dia Pipes
15 mm nominal dia Pipes
Wiring for light point/ fan point/ exhaust fan point/ call bellpoint with 1.5 sq.mm FRLS PVC insulated copper conductorsingle core cable in surface / recessed medium class PVCconduit, with modular switch, modular plate, suitable GI boxand earthing the point with 1.5 sq.mm FRLS PVC insulatedcopper conductor single core cable etc. as required Group C
1.14 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
2 X 4 sq. mm + 1 X 4 sq. mm earth wire
2 X 6 sq. mm + 1 X 6 sq. mm earth wire
4 X 6 sq. mm + 2 X 6 sq. mm earth wire
1.24 Supplying and fixing following modular switch/ socket on theexisting modular plate & switch box including connections butexcluding modular plate etc. as required 5/6 A switch
15/16 A switch
3 pin 5/6 A socket outlet
6 pin 15/16 A socket outlet
Bell push
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing modular blanking plate on the existingmodular plate & switch box excluding modular plate as required.
Supplying and fixing 3 pin, 5 A ceiling rose on the existingjunction box/ wooden block including connections etc. asrequired.
Supplying and fixing call bell/ buzzer suitable for single phase,230 V, complete as required.
Providing and fixing plain 16/0.20mm (0.50sqmm) twin flatflexible, FRLS PVC insulated, copper conductor cable, in PVCsleeve of suitable size on the floor/ wall, or side of the table/door etc. as required
Installation, testing and commissioning of pre-wired,fluorescent fitting / compact fluorescent fitting of all types,complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng andfixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 Amodular switch, connections etc. as required. (For light plugs tobe used in non residential buildings).
Supplying and fixing PVC batten/ angle holder includingconnections etc. as required.
upplying and fixing following way, single pole and neutral,sheet steel, MCB distribution board, 240 V, on surface/ recess,complete with tinned copper bus bar, neutral bus bar, earthbar, din bar, interconnections, powder painted includingearthing etc. as required. (But without MCB/RCCB/Isolator 8 way , Double door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required Single pole
Double pole
2.13 Supplying and fixing following rating, four pole, 415 V isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required100 A
Supplying and fixing following way, horizontal type three poleand neutral, sheet steel, MCB distribution board, 415 V, onsurface/ recess, complete with tinned copper bus bar, neutralbus bar, earth bar, din bar, interconnections, powder paintedincluding earthing etc. as required. (But withoutMCB/RCCB/Isolator)2.4.1 4 way (4 + 12), Double door
2.2 Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required 100 A, 16 KA,TPMCCB
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metrebelow ground as strip earth electrode, including connection/terminating with G.I. nut, bolt, spring, washer etc. as required.(Jointing shall be done by overlapping and with 2 sets of G.I. nutbolt & spring washer spaced at 50mm)
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.7.1.1 Upto 35 sq. mm
Supplying and fixing following size/ modules, GI box alongwithmodular base & cover plate for modular switches in recess etc.as required.1.27.1 1 or 2 Module (75mmX75mm)
3 Module (100mmX75mm)
4 Module (125mmX75mm)
6 Module (200mmX75mm)
8 Module (125mmX125mm)
12 Module (200mmX150mm)
Supply of LED Bulb 12 watt crompton make as specified and directed by the department
Supplying of LED batten 20 Watt Trim line Crompton/Havells/Bajaj /Phillips make as specified and directed by the department
Supplying of A.C. ceiling fan 1200 mm sweep ISI mark Usha or equivalent make as specified and directed by the department
Supply of Exhaust fan 300 mm sweep
Supplying including installation , connection as approved by the department, testing & commissioning of Centrifugal Monoblock Pump set as specific by the department
Payment to APDCL authority load security as per present prevailing norms of APDCL
Metre security 3 phase
Supply of UG cable 10.00 sqmm 4 core XLPE armoured as specified and directed by the department
Supply,installation,testing and commissionig of 25KVA11/0.433KV 50Hz copper wound outdoor type oilfilled(4star/level-II) Transformer complete including all accessories like Earthing terminal,liftunglugs,drain valve,oil filling Hole with plug,Solicagel Breather,First filling of oil as per IS355,Arcing Horn,Radiator,Air Release plug,ConservatorTank etc
Supplying and fixing of 11 KV ADO fuse set complete as required and as directed by the department11 KV DO fuse 150A/400A
Supplying and fixing of 11 KV GOAB switch 400 A Gang operated switch with all accessories complete as required and as directed 11 KV GOAB switch 400A
Supplying of following sizes RCC PSC pole confirming to IS:2713 PSC Pole confirming tIS 2713 as per Quotation enclosed excluding GST taken on 16/8/2021 for 9.75m Pole
Construction of Transformer Pad for DTR as per APDCL norms & as directed by the department.
Supply, instalation , testing and commissioning of 250 Amps, Distribution panel board made out with 1.6 mm CRCA sheet steel, 3 phase suitable for floor mounted , user front facia, powder coated for long lasting finish , cubical type, suitable cable entry provision and including of all necessary electrical protections including , Aluminium Bus bar etc
Erection of RCC/ PCC pole of following length in brick ballastand ramming the foundation, finishing with 150mm thickcement concrete (1:3:6) layer on top with including excavationand refilling etc as required.Above 8.0 metre and upto 11.0 metre
Erection of ACSR conductor of 7/3.35 mm to 7/4.00 diameterand above including binding etc. as required
Supplying and erection of galvanised stay set for 11 KV overhead lines complete with 19/ 20 mm dia X 1.8 metres long stayrod, anchor plate of size 45 cm X 45 cm X 7.5 mm thick, thimble,stay clamps, turn buckle ( 20 mm X 600 mm ), 7/ 4.00 mm diaG.I. stay wire and 11 KV strain insulator etc in cement concrete1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40mm nominal size ) foundation including excavation and refillingetc. as required
Supplying of two lengths of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) double pole cross arm for three wire 11KVover head line conductors complete with through bolts and nutsfor clamping to the poles, 50 mm X 6 mm M.S. flats welded onone side to the channel iron and with bolts and nuts on the otherside for tying the cross arms together, including drilling holes forinsulator pins/ fittings, bolts, nuts and washers etc (as perdrawing) and painting with primer and finish paint as require
Supplying and erection of 11 KV pin insulator complete withlarge steel head G.I. pin, nuts, washers etc. as required
Supplying and erection of 11 KV disc insulator for 11 KV overhead lines with galvanised insulator fittings, ball and sockettype and complete with galvanised strain clamps, bolts, nuts,washers etc. as required
stage.html
html • 0.02 MB
tech_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.46 MB
FOBgotipara.pdf
Additional Documents • 0.06 MB
SBDGotipara.pdf
Tender Documents • 0.74 MB
BOQ_79151.xls
BOQ • 0.42 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .