| 1 | L1₹12.4 LAccepted-AOC 6 KRIPANATH DUTTA ROAD KOLKATA 700 002 | KOLKATA | KOLKATA | WEST BENGAL | 700002 | L1 | Accepted-AOC L1 | |
| 2 | L2₹12.5 L+₹4,100 (0.33%)Rejected-Finance 344 1 SB GORAI ROAD HILL VIEW PARK NORTH ASANSOL | ASANSOL | WEST BENGAL | L2 | Rejected-Finance Higher than L1 | |
| 3 | L3₹12.5 L+₹5,000 (0.40%)Rejected-Finance PATRA MARKET KRISHANAGAR NADIA | KRISHANAGAR | NADIA | L3 | Rejected-Finance Higher than L1 |
Tender Value
Refer Docs
EMD Value
₹25,000
Closing Date
28 Oct 2024, 2:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer
CHETLA
Flow Measurement i.c.w. function ability assessment under Buita and adjoining OHRs under SMD PHE Dte.
2024_PHED_758568_1
WBPHE/EE/SMD/NIeT-31 of 2024-25
Open Tender
Electrical Work/ Equipment
Item Rate
90 days
Buita
Please refer Tender documents.
7 documents required · 7 mandatory
₹25,000
Yes
25 Mar 2025
7 Oct 2024
30 Oct 2024
7 Oct 2024
28 Oct 2024
7 Oct 2024
Amount
Location Nandarampur OHR
Supply and installation of Full bore type Electro Magnetic Flow meter (DN-80) conforming to the enclosed specification in vertical position of suitable man height including weather proof protection panel (comprising of 24VDC SMPS surge protection, over voltage protection, MCB , Indicator etc) with inbuilt RTU with necessary protection ,conduits , cable etc. all complete. The TLS encryption protocol is used for wireless communication between the flow meter and the MQTT broker Installation is including of supplying of relevant pipes, specials viz. DI/MS flanged dismantling joint, companion flanges, slip on flanges, enlarger-reducer, short pieces of required length –required quantities , fasteners, gaskets etc. and fitting & fixing the same in position. by engaging competent man power and applying proper tools and plants followed by testing and commissioning of the entire installation along with the charges for one year subscription for development of web architecture based dashboard for the flow meter and SIM all complete. N.B : Make of all materials should be as per approved vendor list of PHED
Location Buita OHR
Supply and installation of Full bore type Electro Magnetic Flow meter (DN-100) conforming to the enclosed specification in vertical position of suitable man height including weather proof protection panel (comprising of 24VDC SMPS surge protection, over voltage protection, MCB , Indicator etc) with inbuilt RTU with necessary protection ,conduits , cable etc. all complete. The TLS encryption protocol is used for wireless communication between the flow meter and the MQTT broker Installation is including of supplying of relevant pipes, specials viz. DI/MS flanged dismantling joint, companion flanges, slip on flanges, enlarger-reducer, short pieces of required length –required quantities , fasteners, gaskets etc. and fitting & fixing the same in position. by engaging competent man power and applying proper tools and plants followed by testing and commissioning of the entire installation along with the charges for one year subscription for development of web architecture based dashboard for the flow meter and SIM all complete. N.B : Make of all materials should be as per approved vendor list of PHED
Location Uttar Roypur OHR
Supply and installation of Full bore type Electro Magnetic Flow meter (DN-100) conforming to the enclosed specification in vertical position of suitable man height including weather proof protection panel (comprising of 24VDC SMPS surge protection, over voltage protection, MCB , Indicator etc) with inbuilt RTU with necessary protection ,conduits , cable etc. all complete. The TLS encryption protocol is used for wireless communication between the flow meter and the MQTT broker Installation is including of supplying of relevant pipes, specials viz. DI/MS flanged dismantling joint, companion flanges, slip on flanges, enlarger-reducer, short pieces of required length –required quantities , fasteners, gaskets etc. and fitting & fixing the same in position. by engaging competent man power and applying proper tools and plants followed by testing and commissioning of the entire installation along with the charges for one year subscription for development of web architecture based dashboard for the flow meter and SIM all complete. N.B : Make of all materials should be as per approved vendor list of PHED
N.B.: 1. Test Certificate & Calibration certificate of the flowmeter should be submitted at the time of delivery. 2. The system should have a provision for sending data in the end of Server/SCADA/Cloud should be provided and all the requirements for the same need to be furnished at the site end to make a successful communication between device and server /SCADA/ Cloud.
N.B:-All Quoted Rates are inclusive of GST @ 18% + CESS @ 1%
EASTERN INDIA SALES AND SERVICE (BID ID -5711016)
Tarun Kumar Bhattacharya (BID ID -5729045)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .